1
|
Liu C, Cui ZX, Jia S, Cheng J, Liu Y, Lin L, Hu Z, Xie T, Zhou Y, Zhu Y, Liang D, Zeng H, Wang H. DPP: deep phase prior for parallel imaging with wave encoding. Phys Med Biol 2024; 69:105013. [PMID: 38608645 DOI: 10.1088/1361-6560/ad3e5d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Accepted: 04/12/2024] [Indexed: 04/14/2024]
Abstract
Objective.In Magnetic Resonance (MR) parallel imaging with virtual channel-expanded Wave encoding, limitations are imposed on the ability to comprehensively and accurately characterize the background phase. These limitations are primarily attributed to the calibration process relying solely on center low-frequency Auto-Calibration Signals (ACS) data for calibration.Approach.To tackle the challenge of accurately estimating the background phase in wave encoding, a novel deep neural network model guided by deep phase priors is proposed with integrated virtual conjugate coil (VCC) extension. Concretely, within the proposed framework, the background phase is implicitly characterized by employing a carefully designed decoder convolutional neural network, leveraging the inherent characteristics of phase smoothness and compact support in the transformed domain. Furthermore, the proposed model with wave encoding benefits from additional priors, which incorporate transmission sparsity of the latent image and coil sensitivity smoothness.Main results.Ablation experiments were conducted to ascertain the proposed method's capability to implicitly represent CSM and the background phase. Subsequently, the superiority of the proposed method is demonstrated through confidence comparisons with competing methods, employing 4-fold and 5-fold acceleration experiments. In achieving 4-fold and 5-fold acceleration, the optimal quantitative metrics (PSNR/SSIM/NMSE) are 44.1359 dB/0.9863/0.0008 (4-fold) and 41.2074/0.9846/0.0017 (5-fold), respectively. Furthermore, the generalizability of the proposed method is further validated by conducting acceleration experiments with T1, T2, T2*, and various undersampling patterns. In addition, the DPP delivered much better performance than the conventional methods by exploring accelerated phase-sensitive SWI imaging. In SWI accelerated imaging, it also surpasses the optimal competing method in terms of (PSNR/SSIM/NMSE) with 0.096%/0.009%/0.0017%.Significance.The proposed method enables precise characterization of the background phase in the integrated VCC and wave encoding framework, supported via theoretical analysis and empirical findings. Our code is available at:https://github.com/sober235/DPP.
Collapse
Affiliation(s)
- Congcong Liu
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Zhuo-Xu Cui
- Research Center for Medical AI, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Sen Jia
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Jing Cheng
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Yuanyuan Liu
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Ling Lin
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
| | - Zhanqi Hu
- Department of Neurology, Shenzhen Children's Hospital, Shenzhen, Guangdong, People's Republic of China
| | - Taofeng Xie
- Inner Mongolia University, Hohhot, Inner Mongolia, People's Republic of China
- Inner Mongolia Medical University, Hohhot, Inner Mongolia, People's Republic of China
| | - Yihang Zhou
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
- Key Laboratory of Biomedical Imaging Science and System, Chinese Academy of Sciences, People's Republic of China
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, People's Republic of China
| | - Yanjie Zhu
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
- Key Laboratory of Biomedical Imaging Science and System, Chinese Academy of Sciences, People's Republic of China
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, People's Republic of China
| | - Dong Liang
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
- Research Center for Medical AI, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
- Key Laboratory of Biomedical Imaging Science and System, Chinese Academy of Sciences, People's Republic of China
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, People's Republic of China
| | - Hongwu Zeng
- Department of Radiology, Shenzhen Children's Hospital, Shenzhen, Guangdong, People's Republic of China
| | - Haifeng Wang
- Paul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, Guangdong, People's Republic of China
- Key Laboratory of Biomedical Imaging Science and System, Chinese Academy of Sciences, People's Republic of China
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, People's Republic of China
| |
Collapse
|
2
|
Chen Z, Liao C, Cao X, Poser BA, Xu Z, Lo WC, Wen M, Cho J, Tian Q, Wang Y, Feng Y, Xia L, Chen W, Liu F, Bilgic B. 3D-EPI blip-up/down acquisition (BUDA) with CAIPI and joint Hankel structured low-rank reconstruction for rapid distortion-free high-resolution T 2 * mapping. Magn Reson Med 2023; 89:1961-1974. [PMID: 36705076 PMCID: PMC10072851 DOI: 10.1002/mrm.29578] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 12/19/2022] [Accepted: 12/22/2022] [Indexed: 01/28/2023]
Abstract
PURPOSE This work aims to develop a novel distortion-free 3D-EPI acquisition and image reconstruction technique for fast and robust, high-resolution, whole-brain imaging as well as quantitativeT 2 * $$ {\mathrm{T}}_2^{\ast } $$ mapping. METHODS 3D Blip-up and -down acquisition (3D-BUDA) sequence is designed for both single- and multi-echo 3D gradient recalled echo (GRE)-EPI imaging using multiple shots with blip-up and -down readouts to encode B0 field map information. Complementary k-space coverage is achieved using controlled aliasing in parallel imaging (CAIPI) sampling across the shots. For image reconstruction, an iterative hard-thresholding algorithm is employed to minimize the cost function that combines field map information informed parallel imaging with the structured low-rank constraint for multi-shot 3D-BUDA data. Extending 3D-BUDA to multi-echo imaging permitsT 2 * $$ {\mathrm{T}}_2^{\ast } $$ mapping. For this, we propose constructing a joint Hankel matrix along both echo and shot dimensions to improve the reconstruction. RESULTS Experimental results on in vivo multi-echo data demonstrate that, by performing joint reconstruction along with both echo and shot dimensions, reconstruction accuracy is improved compared to standard 3D-BUDA reconstruction. CAIPI sampling is further shown to enhance image quality. ForT 2 * $$ {\mathrm{T}}_2^{\ast } $$ mapping, parameter values from 3D-Joint-CAIPI-BUDA and reference multi-echo GRE are within limits of agreement as quantified by Bland-Altman analysis. CONCLUSIONS The proposed technique enables rapid 3D distortion-free high-resolution imaging andT 2 * $$ {\mathrm{T}}_2^{\ast } $$ mapping. Specifically, 3D-BUDA enables 1-mm isotropic whole-brain imaging in 22 s at 3T and 9 s on a 7T scanner. The combination of multi-echo 3D-BUDA with CAIPI acquisition and joint reconstruction enables distortion-free whole-brainT 2 * $$ {\mathrm{T}}_2^{\ast } $$ mapping in 47 s at 1.1 × 1.1 × 1.0 mm3 resolution.
Collapse
Affiliation(s)
- Zhifeng Chen
- School of Biomedical Engineering, Guangdong Provincial Key Laboratory of Medical Image Processing & Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
- Department of Radiology, Harvard Medical School, Charlestown, MA, USA
- Department of Data Science and AI, Faculty of IT, Monash University, Clayton, VIC, Australia
| | - Congyu Liao
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Xiaozhi Cao
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Benedikt A. Poser
- Maastricht Brain Imaging Center, Faculty of Psychology and Neuroscience, University of Maastricht, the Netherlands
| | - Zhongbiao Xu
- Department of Radiotherapy, Cancer Center, Guangdong Provincial People’s Hospital & Guangdong Academy of Medical Science, Guangzhou, China
| | | | - Manyi Wen
- Department of Chemical Pathology, The Chinese University of Hong Kong, Hong Kong, China
| | - Jaejin Cho
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
- Department of Radiology, Harvard Medical School, Charlestown, MA, USA
| | - Qiyuan Tian
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
- Department of Radiology, Harvard Medical School, Charlestown, MA, USA
| | - Yaohui Wang
- Division of Superconducting Magnet Science and Technology, Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China
| | - Yanqiu Feng
- School of Biomedical Engineering, Guangdong Provincial Key Laboratory of Medical Image Processing & Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence & Key Laboratory of Mental Health of the Ministry of Education, Southern Medical University, Guangzhou, China
| | - Ling Xia
- Department of Biomedical Engineering, Zhejiang University, Hangzhou, China
- Research Center for Healthcare Data Science, Zhejiang Lab, Hangzhou, China
| | - Wufan Chen
- School of Biomedical Engineering, Guangdong Provincial Key Laboratory of Medical Image Processing & Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Feng Liu
- School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD, Australia
| | - Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
- Department of Radiology, Harvard Medical School, Charlestown, MA, USA
- Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, USA
| |
Collapse
|
3
|
Yang C, Liao X, Zhang L, Zhang M, Liu Q. Virtual coil augmentation for MR coil extrapoltion via deep learning. Magn Reson Imaging 2023; 95:1-11. [PMID: 36241031 DOI: 10.1016/j.mri.2022.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 09/29/2022] [Accepted: 10/01/2022] [Indexed: 11/07/2022]
Abstract
Magnetic resonance imaging (MRI) is a widely used medical imaging modality. However, due to the limitations in hardware, scan time, and throughput, it is often clinically challenging to obtain high-quality MR images. In this article, we propose a method of using artificial intelligence to expand the coils to achieve the goal of generating the virtual coils. The main characteristic of our work is utilizing dummy variable technology to expand/extrapolate the receive coils in both image and k-space domains. The high-dimensional information formed by coil expansion is used as the prior information to improve the reconstruction performance of parallel imaging. Two main components are incorporated into the network design, namely variable augmentation technology and sum of squares (SOS) objective function. Variable augmentation provides the network with more high-dimensional prior information, which is helpful for the network to extract the deep feature information of the data. The SOS objective function is employed to solve the deficiency of k-space data training while speeding up convergence. Experimental results demonstrated its great potentials in accelerating parallel imaging reconstruction.
Collapse
Affiliation(s)
- Cailian Yang
- Department of Electronic Information Engineering, Nanchang University, Nanchang 330031, China
| | - Xianghao Liao
- Department of Electronic Information Engineering, Nanchang University, Nanchang 330031, China
| | - Liu Zhang
- Department of Electronic Information Engineering, Nanchang University, Nanchang 330031, China
| | - Minghui Zhang
- Department of Electronic Information Engineering, Nanchang University, Nanchang 330031, China
| | - Qiegen Liu
- Department of Electronic Information Engineering, Nanchang University, Nanchang 330031, China.
| |
Collapse
|
4
|
Li P, Chen J, Nan D, Zou J, Lin D, Hu Y. Motion-Aligned 4D-MRI Reconstruction using Higher Degree Total Variation and Locally Low-Rank Regularization. Magn Reson Imaging 2022; 93:97-107. [DOI: 10.1016/j.mri.2022.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 06/29/2022] [Accepted: 08/02/2022] [Indexed: 11/25/2022]
|
5
|
Chang Y, Zhang J, Pham HA, Li Z, Lyu J. Virtual Conjugate Coil for Improving KerNL Reconstruction. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:599-602. [PMID: 36085691 DOI: 10.1109/embc48229.2022.9871764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Ker NL is a general kernel-based framework for auto calibrated reconstruction method, which does not need any explicit formulas of the kernel function for characterizing nonlinear relationships between acquired and unacquired k-space data. It is non-iterative without requiring a large amount of computational costs. Since the limited autocalibration signals (ACS) are acquired to perform KerNL calibration and the calibration suffers from the overfitting problem, more training data can improve the kernel model accuracy. In this work, virtual conjugate coil data are incorporated into the KerNL calibration and estimation process for enhancing reconstruction performance. Experimental results show that the proposed method can further suppress noise and aliasing artifacts with fewer ACS data and higher acceleration factors. Computation efficiency is still retained to keep fast reconstruction with the random projection.
Collapse
|
6
|
Chang Y, Saritac M. Group feature selection for enhancing information gain in MRI reconstruction. Phys Med Biol 2021; 67. [PMID: 34933300 DOI: 10.1088/1361-6560/ac4561] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 12/21/2021] [Indexed: 11/12/2022]
Abstract
Magnetic resonance imaging (MRI) has revolutionized the radiology. As a leading medical imaging modality, MRI not only visualizes the structures inside body, but also produces functional imaging. However, due to the slow imaging speed constrained by the MR physics, MRI cost is expensive, and patient may feel not comfortable in a scanner for a long time. Parallel MRI has accelerated the imaging speed through the sub-Nyquist sampling strategy and the missing data are interpolated by the multiple coil data acquired. Kernel learning has been used in the parallel MRI reconstruction to learn the interpolation weights and re-construct the undersampled data. However, noise and aliasing artifacts still exist in the reconstructed image and a large number of auto-calibration signal lines are needed. To further improve the kernel learning-based MRI reconstruction and accelerate the speed, this paper proposes a group feature selection strategy to improve the learning performance and enhance the reconstruction quality. An explicit kernel mapping is used for selecting a subset of features which contribute most to estimate the missing k-space data. The experimental results show that the learning behaviours can be better predicted and therefore the reconstructed image quality is improved.
Collapse
Affiliation(s)
- Yuchou Chang
- Computer and Information Science, University of Massachusetts Dartmouth, Dartmouth, Massachusetts, 02747, UNITED STATES
| | - Mert Saritac
- Computer and Information Science, University of Massachusetts Dartmouth, Dartmouth, Dartmouth, Massachusetts, 02747, UNITED STATES
| |
Collapse
|
7
|
Hu Z, Zhao C, Zhao X, Kong L, Yang J, Wang X, Liao J, Zhou Y. Joint reconstruction framework of compressed sensing and nonlinear parallel imaging for dynamic cardiac magnetic resonance imaging. BMC Med Imaging 2021; 21:182. [PMID: 34852771 PMCID: PMC8638482 DOI: 10.1186/s12880-021-00685-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Accepted: 10/06/2021] [Indexed: 02/08/2023] Open
Abstract
Compressed Sensing (CS) and parallel imaging are two promising techniques that accelerate the MRI acquisition process. Combining these two techniques is of great interest due to the complementary information used in each. In this study, we proposed a novel reconstruction framework that effectively combined compressed sensing and nonlinear parallel imaging technique for dynamic cardiac imaging. Specifically, the proposed method decouples the reconstruction process into two sequential steps: In the first step, a series of aliased dynamic images were reconstructed from the highly undersampled k-space data using compressed sensing; In the second step, nonlinear parallel imaging technique, i.e. nonlinear GRAPPA, was utilized to reconstruct the original dynamic images from the reconstructed k-space data obtained from the first step. In addition, we also proposed a tailored k-space down-sampling scheme that satisfies both the incoherent undersampling requirement for CS and the structured undersampling requirement for nonlinear parallel imaging. The proposed method was validated using four in vivo experiments of dynamic cardiac cine MRI with retrospective undersampling. Experimental results showed that the proposed method is superior at reducing aliasing artifacts and preserving the spatial details and temporal variations, compared with the competing k-t FOCUSS and k-t FOCUSS with sensitivity encoding methods, with the same numbers of measurements.
Collapse
Affiliation(s)
- Zhanqi Hu
- grid.452787.b0000 0004 1806 5224Shenzhen Children’s Hospital, Shenzhen, 518038 Guangdong China
| | - Cailei Zhao
- grid.452787.b0000 0004 1806 5224Shenzhen Children’s Hospital, Shenzhen, 518038 Guangdong China
| | - Xia Zhao
- grid.452787.b0000 0004 1806 5224Shenzhen Children’s Hospital, Shenzhen, 518038 Guangdong China
| | - Lingyu Kong
- grid.452787.b0000 0004 1806 5224Shenzhen Children’s Hospital, Shenzhen, 518038 Guangdong China
| | - Jun Yang
- grid.410726.60000 0004 1797 8419Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, 518055 Guangdong China
| | - Xiaoyan Wang
- grid.464483.90000 0004 1799 4419School of Physics and Electronic Engineering, Yuxi Normal University, Yuxi, 653100 Yunnan China
| | - Jianxiang Liao
- grid.452787.b0000 0004 1806 5224Shenzhen Children’s Hospital, Shenzhen, 518038 Guangdong China
| | - Yihang Zhou
- grid.414329.90000 0004 1764 7097Hong Kong Sanatorium and Hospital, 5 A Kung Ngam Village Road, Shau Kei Wan, Hong Kong, China
| |
Collapse
|
8
|
Sheng J, Shi Y, Zhang Q. Improved parallel magnetic resonance imaging reconstruction with multiple variable density sampling. Sci Rep 2021; 11:9005. [PMID: 33903702 PMCID: PMC8076203 DOI: 10.1038/s41598-021-88567-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Accepted: 04/05/2021] [Indexed: 11/29/2022] Open
Abstract
Generalized auto-calibrating partially parallel acquisitions (GRAPPA) and other parallel Magnetic Resonance Imaging (pMRI) methods restore the unacquired data in k-space by linearly calculating the undersampled data around the missing points. In order to obtain the weight of the linear calculation, a small number of auto-calibration signal (ACS) lines need to be sampled at the center of the k-space. Therefore, the sampling pattern used in this type of method is to full sample data in the middle area and undersample in the outer k-space with nominal reduction factors. In this paper, we propose a novel reconstruction method with a multiple variable density sampling (MVDS) that is different from traditional sampling patterns. Our method can significantly improve the image quality using multiple reduction factors with fewer ACS lines. Specifically, the traditional sampling pattern only uses a single reduction factor to uniformly undersample data in the region outside the ACS, but we use multiple reduction factors. When sampling the k-space data, we keep the ACS lines unchanged, use a smaller reduction factor for undersampling data near the ACS lines and a larger reduction factor for the outermost part of k-space. The error is lower after reconstruction of this region by undersampled data with a smaller reduction factor. The experimental results show that with the same amount of data sampled, using NL-GRAPPA to reconstruct the k-space data sampled by our method can result in lower noise and fewer artifacts than traditional methods. In particular, our method is extremely effective when the number of ACS lines is small.
Collapse
Affiliation(s)
- Jinhua Sheng
- College of Computer Science, Hangzhou Dianzi University, Hangzhou, 310018, Zhejiang, China.
- Key Laboratory of Intelligent Image Analysis for Sensory and Cognitive Health, Ministry of Industry and Information Technology of China, Hangzhou, 310018, Zhejiang, China.
| | - Yuchen Shi
- College of Computer Science, Hangzhou Dianzi University, Hangzhou, 310018, Zhejiang, China
- Key Laboratory of Intelligent Image Analysis for Sensory and Cognitive Health, Ministry of Industry and Information Technology of China, Hangzhou, 310018, Zhejiang, China
| | - Qiao Zhang
- Beijing Hospital, Beijing, 100730, China
| |
Collapse
|
9
|
Zhu Y, Liu Y, Ying L, Qiu Z, Liu Q, Jia S, Wang H, Peng X, Liu X, Zheng H, Liang D. A 4-minute solution for submillimeter whole-brain T 1ρ quantification. Magn Reson Med 2021; 85:3299-3307. [PMID: 33421224 DOI: 10.1002/mrm.28656] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 12/02/2020] [Accepted: 12/04/2020] [Indexed: 12/12/2022]
Abstract
PURPOSE To develop a robust, accurate, and accelerated T1ρ quantification solution for submillimeter in vivo whole-brain imaging. METHODS A multislice T1ρ mapping solution (MS-T1ρ ) was developed based on a two-acquisition scheme using turbo spin echo with RF cycling to allow for whole-brain coverage with 0.8-mm in-plane resolution. A compressed sensing-based fast imaging method, SCOPE, was used to accelerate the MS-T1ρ acquisition time to a total scan time of 3 minutes 31 seconds. A phantom experiment was conducted to assess the accuracy of MS-T1ρ by comparing the T1ρ value obtained using MS-T1ρ with the reference value obtained using the standard single-slice T1ρ mapping method. In vivo scans of 13 volunteers were acquired prospectively to validate the robustness of MS-T1ρ . RESULTS In the phantom study, the T1ρ values obtained with MS-T1ρ were in good agreement with the reference T1ρ values (R2 = 0.9991) and showed high consistency throughout all slices (coefficient of variation = 2.2 ± 2.43%). In the in vivo experiments, T1ρ maps were successfully acquired for all volunteers with no visually noticeable artifacts. There was no significant difference in T1ρ values between MS-T1ρ acquisitions and fully sampled acquisitions for all brain tissues (p-value > .05). In the intraclass correlation coefficient and Bland-Altman analyses, the accelerated T1ρ measurements show moderate to good agreement to the fully sampled reference values. CONCLUSION The proposed MS-T1ρ solution allows for high-resolution whole-brain T1ρ mapping within 4 minutes and may provide a potential tool for investigating neural diseases.
Collapse
Affiliation(s)
- Yanjie Zhu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Yuanyuan Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China.,University of Chinese Academy of Sciences, Beijing, 100049, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Leslie Ying
- Department of Biomedical Engineering and Department of Electrical Engineering, University at Buffalo, The State University of New York, Buffalo, New York, 14260, USA
| | - Zhilang Qiu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China.,University of Chinese Academy of Sciences, Beijing, 100049, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Qiegen Liu
- Department of Electronic Information Engineering, Nanchang University, Nanchang, Jiangxi, 330031, China
| | - Sen Jia
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Haifeng Wang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Xi Peng
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, 55905, USA
| | - Xin Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Dong Liang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| |
Collapse
|
10
|
Laib Z, Ahmed Sid F, Abed-Meraim K, Ouldali A. Estimation error bound for GRAPPA diffusion-weighted MRI. Magn Reson Imaging 2020; 74:181-194. [PMID: 33010376 DOI: 10.1016/j.mri.2020.09.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 08/26/2020] [Accepted: 09/23/2020] [Indexed: 01/08/2023]
Abstract
In recent years, diffusion weight magnetic resonance imaging (DW-MRI) has become one of the most important MRI imaging modalities. The importance of the DW-MRI grew thanks to the combination of parallel magnetic resonance imaging (pMRI) techniques with the echo-planar imaging (EPI), which minimize scan time and lead to reduced distortion, allowing the DW-MRI to become a routine clinical exam. Additionally, this has brought various new parameters that influence image quality and biomarkers used in DW-MRI. This work aims to investigate the effects of these parameters on the estimation quality, by using the Cramér-Rao bound tool, which gives analytical expressions of the lower limit on the estimation error variance of different DW-MRI variables when using the pMRI technique. In particular, these bounds will be used to study and optimize the impact of different factors of generalized autocalibrating partially parallel acquisition (GRAPPA) technique and system parameters on the estimation quality of the desired clinical metrics. Moreover, the obtained results of this study can be exploited and adapted in all human body DW-MRI clinical routines, further improving disease diagnosis, and tractography studies.
Collapse
Affiliation(s)
- Zohir Laib
- Laboratoire traitement du signal, EMP, BP 17 Bordj El Bahri, 16111 Algiers, Algeria.
| | - Farid Ahmed Sid
- ParIMéd/LRPE,FEI,USTHB, BP 32 El Alia, Bab Ezzouar, 16111 Algiers, Algeria
| | - Karim Abed-Meraim
- PRISME Laboratory, University of Orléans, 12 Rue de Blois, 45067 Orléans, France
| | - Aziz Ouldali
- Laboratoire signaux et systemes, University of Mostaganem, BP 002 Kharouba, 27000 Mostaganem, Algeria
| |
Collapse
|