1
|
McWilliam A, Palma G, Abravan A, Acosta O, Appelt A, Aznar M, Monti S, Onjukka E, Panettieri V, Placidi L, Rancati T, Vasquez Osorio E, Witte M, Cella L. Voxel-based analysis: Roadmap for clinical translation. Radiother Oncol 2023; 188:109868. [PMID: 37683811 DOI: 10.1016/j.radonc.2023.109868] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 07/11/2023] [Accepted: 08/20/2023] [Indexed: 09/10/2023]
Abstract
Voxel-based analysis (VBA) allows the full, 3-dimensional, dose distribution to be considered in radiotherapy outcome analysis. This provides new insights into anatomical variability of pathophysiology and radiosensitivity by removing the need for a priori definition of organs assumed to drive the dose response associated with patient outcomes. This approach may offer powerful biological insights demonstrating the heterogeneity of the radiobiology across tissues and potential associations of the radiotherapy dose with further factors. As this methodological approach becomes established, consideration needs to be given to translating VBA results to clinical implementation for patient benefit. Here, we present a comprehensive roadmap for VBA clinical translation. Technical validation needs to demonstrate robustness to methodology, where clinical validation must show generalisability to external datasets and link to a plausible pathophysiological hypothesis. Finally, clinical utility requires demonstration of potential benefit for patients in order for successful translation to be feasible. For each step on the roadmap, key considerations are discussed and recommendations provided for best practice.
Collapse
Affiliation(s)
- Alan McWilliam
- The Division of Cancer Sciences, The University of Manchester, Manchester, UK; The Christie NHS Foundation Trust, Manchester, UK.
| | - Giuseppe Palma
- Institute of Nanotechnology, National Research Council, Lecce, Italy.
| | - Azadeh Abravan
- The Division of Cancer Sciences, The University of Manchester, Manchester, UK; The Christie NHS Foundation Trust, Manchester, UK
| | - Oscar Acosta
- University Rennes, CLCC Eugène Marquis, INSERM, LTSI - UMR 1099, F-35000, Rennes, France
| | - Ane Appelt
- Leeds Institute of Medical Research at St James's, University of Leeds, Leeds, UK
| | - Marianne Aznar
- The Division of Cancer Sciences, The University of Manchester, Manchester, UK; The Christie NHS Foundation Trust, Manchester, UK
| | - Serena Monti
- Institute of Biostructures and Bioimaging, National Research Council, Naples, Italy
| | - Eva Onjukka
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Sweden
| | - Vanessa Panettieri
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia; Central Clinical School, Monash University, Melbourne, VIC, Australia; Sir Peter MacCallum Department of Oncology, The University of Melbourne, Victoria 3010, Australia
| | - Lorenzo Placidi
- Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Rome, Italy
| | - Tiziana Rancati
- Data Science Unit, Fondazione IRCCS Istituto Nazionale dei Tumori, Milano, Italy
| | - Eliana Vasquez Osorio
- The Division of Cancer Sciences, The University of Manchester, Manchester, UK; The Christie NHS Foundation Trust, Manchester, UK
| | - Marnix Witte
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, the Netherlands
| | - Laura Cella
- Institute of Biostructures and Bioimaging, National Research Council, Naples, Italy
| |
Collapse
|
2
|
Szmul A, Taylor S, Lim P, Cantwell J, Moreira I, Zhang Y, D’Souza D, Moinuddin S, Gaze MN, Gains J, Veiga C. Deep learning based synthetic CT from cone beam CT generation for abdominal paediatric radiotherapy. Phys Med Biol 2023; 68:105006. [PMID: 36996837 PMCID: PMC10160738 DOI: 10.1088/1361-6560/acc921] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 03/13/2023] [Accepted: 03/30/2023] [Indexed: 04/01/2023]
Abstract
Objective. Adaptive radiotherapy workflows require images with the quality of computed tomography (CT) for re-calculation and re-optimisation of radiation doses. In this work we aim to improve the quality of on-board cone beam CT (CBCT) images for dose calculation using deep learning.Approach. We propose a novel framework for CBCT-to-CT synthesis using cycle-consistent Generative Adversarial Networks (cycleGANs). The framework was tailored for paediatric abdominal patients, a challenging application due to the inter-fractional variability in bowel filling and small patient numbers. We introduced to the networks the concept of global residuals only learning and modified the cycleGAN loss function to explicitly promote structural consistency between source and synthetic images. Finally, to compensate for the anatomical variability and address the difficulties in collecting large datasets in the paediatric population, we applied a smart 2D slice selection based on the common field-of-view (abdomen) to our imaging dataset. This acted as a weakly paired data approach that allowed us to take advantage of scans from patients treated for a variety of malignancies (thoracic-abdominal-pelvic) for training purposes. We first optimised the proposed framework and benchmarked its performance on a development dataset. Later, a comprehensive quantitative evaluation was performed on an unseen dataset, which included calculating global image similarity metrics, segmentation-based measures and proton therapy-specific metrics.Main results. We found improved performance for our proposed method, compared to a baseline cycleGAN implementation, on image-similarity metrics such as Mean Absolute Error calculated for a matched virtual CT (55.0 ± 16.6 HU proposed versus 58.9 ± 16.8 HU baseline). There was also a higher level of structural agreement for gastrointestinal gas between source and synthetic images measured using the dice similarity coefficient (0.872 ± 0.053 proposed versus 0.846 ± 0.052 baseline). Differences found in water-equivalent thickness metrics were also smaller for our method (3.3 ± 2.4% proposed versus 3.7 ± 2.8% baseline).Significance. Our findings indicate that our innovations to the cycleGAN framework improved the quality and structure consistency of the synthetic CTs generated.
Collapse
Affiliation(s)
- Adam Szmul
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, United Kingdom
| | - Sabrina Taylor
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Pei Lim
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Jessica Cantwell
- Radiotherapy, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Isabel Moreira
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Ying Zhang
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Derek D’Souza
- Radiotherapy Physics Services, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Syed Moinuddin
- Radiotherapy, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Mark N. Gaze
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Jennifer Gains
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Catarina Veiga
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| |
Collapse
|
3
|
Wilson LJ, Kiffer FC, Berrios DC, Bryce-Atkinson A, Costes SV, Gevaert O, Matarèse BFE, Miller J, Mukherjee P, Peach K, Schofield PN, Slater LT, Langen B. Machine intelligence for radiation science: summary of the Radiation Research Society 67th annual meeting symposium. Int J Radiat Biol 2023:1-10. [PMID: 36735963 DOI: 10.1080/09553002.2023.2173823] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The era of high-throughput techniques created big data in the medical field and research disciplines. Machine intelligence (MI) approaches can overcome critical limitations on how those large-scale data sets are processed, analyzed, and interpreted. The 67th Annual Meeting of the Radiation Research Society featured a symposium on MI approaches to highlight recent advancements in the radiation sciences and their clinical applications. This article summarizes three of those presentations regarding recent developments for metadata processing and ontological formalization, data mining for radiation outcomes in pediatric oncology, and imaging in lung cancer.
Collapse
Affiliation(s)
- Lydia J Wilson
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Frederico C Kiffer
- Department of Anesthesia and Critical Care Medicine, The Children's Hospital of Philadelphia Research Institute, Philadelphia, PA, USA
| | | | - Abigail Bryce-Atkinson
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | | | - Olivier Gevaert
- Stanford Center for Biomedical Informatics Research, Department of Medicine, Stanford, CA, USA
- Department of Biomedical Data Science, Stanford University, Palo Alto, CA, USA
| | - Bruno F E Matarèse
- The Cavendish Laboratory, University of Cambridge, Cambridge, UK
- Department of Haematology, School of Clinical Medicine, University of Cambridge, Cambridge, UK
| | - Jack Miller
- NASA Ames Research Center, Moffett Field, CA, USA
- KBR, NASA Ames Research Center, Moffett Field, CA, USA
| | - Pritam Mukherjee
- Stanford Center for Biomedical Informatics Research, Department of Medicine, Stanford, CA, USA
- Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD, USA
| | - Kristen Peach
- Department of Bionetics, NASA Ames Research Center, Moffett Field, CA, USA
| | - Paul N Schofield
- Department of Physiology Development and Neuroscience, University of Cambridge, Cambridge, UK
| | - Luke T Slater
- Institute of Cancer and Genomic Sciences, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK
- Institute of Translational Medicine, University Hospitals Birmingham, NHS Foundation Trust, Birmingham, UK
- MRC Health Data Research UK (HDR UK), Midlands, UK
| | - Britta Langen
- Department of Radiation Oncology, Section of Molecular Radiation Biology, UT Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
4
|
Zhang Y, Alshaikhi J, Amos RA, Tan W, Anaya VM, Pang Y, Royle G, Bär E. Pre-treatment analysis of non-rigid variations can assist robust intensity-modulated proton therapy plan selection for head and neck patients. Med Phys 2022; 49:7683-7693. [PMID: 36083223 PMCID: PMC10092578 DOI: 10.1002/mp.15971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 08/13/2022] [Accepted: 08/27/2022] [Indexed: 12/27/2022] Open
Abstract
PURPOSE To incorporate small non-rigid variations of head and neck patients into the robust evaluation of intensity-modulated proton therapy (IMPT) for the selection of robust treatment plans. METHODS A cohort of 20 nasopharynx cancer patients with weekly kilovoltage CT (kVCT) and 15 oropharynx cancer patients with weekly cone-beam CT (CBCT) were retrospectively included. Anatomical variations between week 0/week 1 of treatment were acquired using deformable image registration (DIR) for all 35 patients and then applied to the planning CT of four patients who have kVCT scanned each week to simulate potential small non-rigid variations (sNRVs). The robust evaluations were conducted on IMPT plans with: (1) different number of beam fields from 3-field to 5-field; (2) different beam angles. The robust evaluation before treatment, including the sNRVs and setup uncertainty, referred to as sNRV+R evaluation was compared with the conventional evaluation (without sNRVs) in terms of robustness consistency with the gold standard evaluation based on weekly CT. RESULTS Among four patients (490 scenarios), we observed a maximum difference in the sNRV+R evaluation to the nominal dose of: 9.37% dose degradation on D95 of clinical target volumes (CTVs), increase in mean dose (D mean $_{\text{mean}}$ ) of parotid 11.87 Gy, increase in max dose (D max $_{\text{max}}$ ) of brainstem 20.82 Gy. In contrast, in conventional evaluation, we observed a maximum difference to the nominal dose of: 7.58% dose degradation on D95 of the CTVs, increase in parotid D mean $_{\text{mean}}$ by 4.88 Gy, increase in brainstem D max $_{\text{max}}$ by 13.5 Gy. In the measurement of the robustness ranking consistency with the gold standard evaluation, the sNRV+R evaluation was better or equal to the conventional evaluation in 77% of cases, particularly, better on spinal cord, parotid glands, and low-risk CTV. CONCLUSION This study demonstrated the additional dose discrepancy that sNRVs can make. The inclusion of sNRVs can be beneficial to robust evaluation, providing information on clinical uncertainties additional to the conventional rigid isocenter shift.
Collapse
Affiliation(s)
- Ying Zhang
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, UK
| | - Jailan Alshaikhi
- Saudi Proton Therapy Center, King Fahad Medical City, Riyadh, Saudi Arabia
| | - Richard A Amos
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, UK
| | - Wenyong Tan
- Department of Oncology, Shenzhen Hospital of Southern Medical University Shenzhen, Guangdong, China
| | - Virginia Marin Anaya
- University College London Hospitals NHS Foundation Trust, Radiotherapy Physics, London, UK
| | - Yaru Pang
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, UK
| | - Gary Royle
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, UK
| | - Esther Bär
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, UK.,University College London Hospitals NHS Foundation Trust, Radiotherapy Physics, London, UK
| |
Collapse
|
5
|
Wilson LJ, Bryce-Atkinson A, Green A, Li Y, Merchant TE, van Herk M, Vasquez Osorio E, Faught AM, Aznar MC. Image-based data mining applies to data collected from children. Phys Med 2022; 99:31-43. [PMID: 35609381 PMCID: PMC9197776 DOI: 10.1016/j.ejmp.2022.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 04/14/2022] [Accepted: 05/07/2022] [Indexed: 11/25/2022] Open
Abstract
PURPOSE Image-based data mining (IBDM) is a novel voxel-based method for analyzing radiation dose responses that has been successfully applied in adult data. Because anatomic variability and side effects of interest differ for children compared to adults, we investigated the feasibility of IBDM for pediatric analyses. METHODS We tested IBDM with CT images and dose distributions collected from 167 children (aged 10 months to 20 years) who received proton radiotherapy for primary brain tumors. We used data from four reference patients to assess IBDM sensitivity to reference selection. We quantified spatial-normalization accuracy via contour distances and deviations of the centers-of-mass of brain substructures. We performed dose comparisons with simplified and modified clinical dose distributions with a simulated effect, assessing their accuracy via sensitivity, positive predictive value (PPV) and Dice similarity coefficient (DSC). RESULTS Spatial normalizations and dose comparisons were insensitive to reference selection. Normalization discrepancies were small (average contour distance < 2.5 mm, average center-of-mass deviation < 6 mm). Dose comparisons identified differences (p < 0.01) in 81% of simplified and all modified clinical dose distributions. The DSCs for simplified doses were high (peak frequency magnitudes of 0.9-1.0). However, the PPVs and DSCs were low (maximum 0.3 and 0.4, respectively) in the modified clinical tests. CONCLUSIONS IBDM is feasible for childhood late-effects research. Our findings may inform cohort selection in future studies of pediatric radiotherapy dose responses and facilitate treatment planning to reduce treatment-related toxicities and improve quality of life among childhood cancer survivors.
Collapse
Affiliation(s)
- Lydia J Wilson
- St. Jude Children's Research Hospital, Department of Radiation Oncology, Memphis, TN, USA.
| | - Abigail Bryce-Atkinson
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Andrew Green
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Yimei Li
- St. Jude Children's Research Hospital, Department of Biostatistics, Memphis, TN, USA
| | - Thomas E Merchant
- St. Jude Children's Research Hospital, Department of Radiation Oncology, Memphis, TN, USA
| | - Marcel van Herk
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Eliana Vasquez Osorio
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Austin M Faught
- St. Jude Children's Research Hospital, Department of Radiation Oncology, Memphis, TN, USA
| | - Marianne C Aznar
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| |
Collapse
|