1
|
Amini S, Choi H, Seche W, Blagojevic A, May N, Lefler BM, Davis SL, Elyahoodayan S, Tavousi P, May SJ, Caputo GA, Lowe TC, Hettinger J, Shahbazmohamadi S. Sustainability inspired fabrication of next generation neurostimulation and cardiac rhythm management electrodes via reactive hierarchical surface restructuring. MICROSYSTEMS & NANOENGINEERING 2024; 10:125. [PMID: 39251609 PMCID: PMC11384795 DOI: 10.1038/s41378-024-00754-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 06/05/2024] [Accepted: 06/23/2024] [Indexed: 09/11/2024]
Abstract
Over the last two decades, platinum group metals (PGMs) and their alloys have dominated as the materials of choice for electrodes in long-term implantable neurostimulation and cardiac rhythm management devices due to their superior conductivity, mechanical and chemical stability, biocompatibility, corrosion resistance, radiopacity, and electrochemical performance. Despite these benefits, PGM manufacturing processes are extremely costly, complex, and challenging with potential health hazards. Additionally, the volatility in PGM prices and their high supply risk, combined with their scarce concentration of approximately 0.01 ppm in the earth's upper crust and limited mining geographical areas, underscores their classification as critical raw materials, thus, their effective recovery or substitution worldwide is of paramount importance. Since postmortem recovery from deceased patients and/or refining of PGMs that are used in the manufacturing of the electrodes and microelectrode arrays is extremely rare, challenging, and highly costly, therefore, substitution of PGM-based electrodes with other biocompatible materials that can yield electrochemical performance values equal or greater than PGMs is the only viable and sustainable solution to reduce and ultimately substitute the use of PGMs in long-term implantable neurostimulation and cardiac rhythm management devices. In this article, we demonstrate for the first time how the novel technique of "reactive hierarchical surface restructuring" can be utilized on titanium-that is widely used in many non-stimulation medical device and implant applications-to manufacture biocompatible, low-cost, sustainable, and high-performing neurostimulation and cardiac rhythm management electrodes. We have shown how the surface of titanium electrodes with extremely poor electrochemical performance undergoes compositional and topographical transformations that result in electrodes with outstanding electrochemical performance.
Collapse
Affiliation(s)
- Shahram Amini
- Research and Development, Pulse Technologies Inc., Quakertown, PA, USA.
- Biomedical Engineering Department, University of Connecticut, Storrs, CT, USA.
| | - Hongbin Choi
- Biomedical Engineering Department, University of Connecticut, Storrs, CT, USA
| | - Wesley Seche
- Research and Development, Pulse Technologies Inc., Quakertown, PA, USA
| | | | - Nicholas May
- Biomedical Engineering Department, University of Connecticut, Storrs, CT, USA
| | - Benjamin M Lefler
- Department of Materials Science and Engineering, Drexel University, Philadelphia, PA, USA
| | - Skyler L Davis
- Department of Metallurgical and Materials Engineering, Colorado School of Mines, Golden, CO, USA
| | - Sahar Elyahoodayan
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
| | - Pouya Tavousi
- Biomedical Engineering Department, University of Connecticut, Storrs, CT, USA
| | - Steven J May
- Department of Materials Science and Engineering, Drexel University, Philadelphia, PA, USA
| | - Gregory A Caputo
- Department of Chemistry and Biochemistry, Rowan University, Glassboro, NJ, USA
| | - Terry C Lowe
- Department of Metallurgical and Materials Engineering, Colorado School of Mines, Golden, CO, USA
| | - Jeffrey Hettinger
- Department of Physics and Astronomy, Rowan University, Glassboro, NJ, USA
| | | |
Collapse
|
2
|
O’Sullivan KP, Orazem ME, Otto KJ, Butson CR, Baker JL. Electrical rejuvenation of chronically implanted macroelectrodes in nonhuman primates. J Neural Eng 2024; 21:10.1088/1741-2552/ad5703. [PMID: 38862007 PMCID: PMC11302379 DOI: 10.1088/1741-2552/ad5703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 06/11/2024] [Indexed: 06/13/2024]
Abstract
Objective.Electrodes chronically implanted in the brain undergo complex changes over time that can lower the signal to noise ratio (SNR) of recorded signals and reduce the amount of energy delivered to the tissue during therapeutic stimulation, both of which are relevant for the development of robust, closed-loop control systems. Several factors have been identified that link changes in the electrode-tissue interface (ETI) to increased impedance and degraded performance in micro- and macro-electrodes. Previous studies have demonstrated that brief pulses applied every few days can restore SNR to near baseline levels during microelectrode recordings in rodents, a process referred to as electrical rejuvenation. However, electrical rejuvenation has not been tested in clinically relevant macroelectrode designs in large animal models, which could serve as preliminary data for translation of this technique. Here, several variations of this approach were tested to characterize parameters for optimization.Approach. Alternating-current (AC) and direct-current (DC) electrical rejuvenation methods were explored in three electrode types, chronically implanted in two adult male nonhuman primates (NHP) (Macaca mulatta), which included epidural electrocorticography (ECoG) electrodes and penetrating deep-brain stimulation (DBS) electrodes. Electrochemical impedance spectroscopy (EIS) was performed before and after each rejuvenation paradigm as a gold standard measure of impedance, as well as at subsequent intervals to longitudinally track the evolution of the ETI. Stochastic error modeling was performed to assess the standard deviation of the impedance data, and consistency with the Kramers-Kronig relations was assessed to evaluate the stationarity of EIS measurement.Main results. AC and DC rejuvenation were found to quickly reduce impedance and minimize the tissue component of the ETI on all three electrode types, with DC and low-frequency AC producing the largest impedance drops and reduction of the tissue component in Nyquist plots. The effects of a single rejuvenation session were found to last from several days to over 1 week, and all rejuvenation pulses induced no observable changes to the animals' behavior.Significance. These results demonstrate the effectiveness of electrical rejuvenation for diminishing the impact of chronic ETI changes in NHP with clinically relevant macroelectrode designs.
Collapse
Affiliation(s)
- KP O’Sullivan
- Department of Biomedical Engineering, University of Utah, 36 S Wasatch Dr, Salt Lake City, UT 84112
| | - ME Orazem
- Department of Chemical Engineering, Herbert Wertheim College of Engineering, University of Florida, 1030 Center Drive P.O. Box 116005 Gainesville, FL 32611
| | - KJ Otto
- J. Crayton Pruitt Family Department of Biomedical Engineering, Herbert Wertheim College of Engineering, University of Florida, 1275 Center Drive, NEB 363, P.O. Box 116131, Gainesville, FL 32611
- Department of Neuroscience, University of Florida, Gainesville, FL, United States
- Department of Neurology, University of Florida, Gainesville, FL, United States
- Department of Materials Science and Engineering, University of Florida, Gainesville, FL, United States
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, United States
| | - CR Butson
- Department of Biomedical Engineering, University of Utah, 36 S Wasatch Dr, Salt Lake City, UT 84112
- J. Crayton Pruitt Family Department of Biomedical Engineering, Herbert Wertheim College of Engineering, University of Florida, 1275 Center Drive, NEB 363, P.O. Box 116131, Gainesville, FL 32611
- Norman Fixel Institute for Neurological Diseases, University of Florida, 3009 Williston Road, Gainesville, FL 32608
| | - JL Baker
- Brain and Mind Research Institute, Weil Cornell Medical College, 407 E 61 St, New York, NY 10065
| |
Collapse
|
3
|
Cha JH, Park JH, Park Y, Shin H, Hwang KS, Cho IJ, Kim SJ. A CMOS Microelectrode Array System With Reconfigurable Sub-Array Multiplexing Architecture Integrating 24,320 Electrodes and 380 Readout Channels. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:1044-1056. [PMID: 36191109 DOI: 10.1109/tbcas.2022.3211275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
This article presents a CMOS microelectrode array (MEA) system with a reconfigurable sub-array multiplexing architecture using the time-division multiplexing (TDM) technique. The system consists of 24,320 TiN electrodes with 17.7 μm-pitch pixels and 380 column-parallel readout channels including a low-noise amplifier, a programmable gain amplifier, and a 10-b successive approximation register analog to digital converter. Readout channels are placed outside the pixel for high spatial resolution, and a flexible structure to acquire neural signals from electrodes selected by configuring in-pixel memory is realized. In this structure, a single channel can handle 8 to 32 electrodes, guaranteeing a temporal resolution from 5 kS/s to 20 kS/s for each electrode. A 128 × 190 MEA system was fabricated in a 110-nm CMOS process, and each readout channel consumes 81 μW at 1.5-V supply voltage featuring input-referred noise of 1.48 μVrms without multiplexing and 5.4 μVrms with multiplexing at the action-potential band (300 Hz-10 kHz).
Collapse
|
4
|
Brunton EK, Silveira C, Rosenberg J, Schiefer MA, Riddell J, Nazarpour K. Temporal Modulation of the Response of Sensory Fibers to Paired-Pulse Stimulation. IEEE Trans Neural Syst Rehabil Eng 2019; 27:1676-1683. [DOI: 10.1109/tnsre.2019.2935813] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
5
|
5-Methoxy-N,N-dimethyltryptamine: An Ego-Dissolving Endogenous Neurochemical Catalyst of Creativity. ACTA ACUST UNITED AC 2019. [DOI: 10.1007/s41470-019-00063-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
6
|
A novel simplistic fabrication technique for cranial epidural electrodes for chronic recording and stimulation in rats. J Neurosci Methods 2019; 311:239-242. [PMID: 30389487 DOI: 10.1016/j.jneumeth.2018.10.036] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Revised: 09/18/2018] [Accepted: 10/29/2018] [Indexed: 01/02/2023]
Abstract
BACKGROUND The demand for neuromodulatory and recording tools has resulted in a surge of publications describing techniques for fabricating devices and accessories in-house suitable for neurological recordings. However, many of these fabrication protocols use equipment which are not common to biological laboratories, thus limiting researchers to the use of commercial alternatives. New method:We have developed a simple yet robust implantable stimulating surface electrode which can be fabricated in all wet-bench laboratories. RESULTS Female Sprague-Dawley rats received epidural implantation of the electrodes over the fore and hind limb areas of their motor cortex. Stimulation of the motor cortex successfully evoked fore- and hind limb motor outputs. The device was also able to record surface potentials of the motor cortex following epidural stimulation of the spinal cord. Comparisons with existing methods:For stimulation of the motor cortex, often stiff stainless or copper wires are roughly tucked underneath the skull, with little accuracy of localization. While, commercially available devices utilize burr holes and screw electrodes. Our new electrode design provides us stereotaxic accuracy that was not previously available. CONCLUSION We developed a chronic implantable electrode capable of being fabricated in all wet-labs, are robust, versatile and electrically sensitive enough for long-term chronic use. The simple and versatile electrode design provides scientific, economical and ethical benefits.
Collapse
|
7
|
Niketeghad S, Pouratian N. Brain Machine Interfaces for Vision Restoration: The Current State of Cortical Visual Prosthetics. Neurotherapeutics 2019; 16:134-143. [PMID: 30194614 PMCID: PMC6361050 DOI: 10.1007/s13311-018-0660-1] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Loss of vision alters the day to day life of blind individuals and may impose a significant burden on their family and the economy. Cortical visual prosthetics have been shown to have the potential of restoring a useful degree of vision via stimulation of primary visual cortex. Due to current advances in electrode design and wireless power and data transmission, development of these prosthetics has gained momentum in the past few years and multiple sites around the world are currently developing and testing their designs. In this review, we briefly outline the visual prosthetic approaches and describe the history of cortical visual prosthetics. Next, we focus on the state of the art of cortical visual prosthesis by briefly explaining the design of current devices that are either under development or in the clinical testing phase. Lastly, we shed light on the challenges of each design and provide some potential solutions.
Collapse
Affiliation(s)
- Soroush Niketeghad
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Nader Pouratian
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA.
- Department of Neurosurgery, University of California Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
8
|
Brunton E, Silveira C, Riddell J, Nazarpour K. Recovery of the Response of Sensory Fibers to the Second of a Pair of Peripheral Nerve Stimuli. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:1214-1217. [PMID: 30440608 DOI: 10.1109/embc.2018.8512560] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Neural interfaces that stimulate the peripheral nerves have the potential to provide sensory feedback from artificial hands. Many neural interfaces are now being developed that allow for multi-channel stimulation of nerves. It is widely accepted that the electric fields generated by two or more contacts on a neural interface can interact. However, this has previously not been examined in the context of sensory feedback prostheses. Here, we aimed to investigate these interactions and the recovery dynamics of the sensory fibers. A multi-channel cuff electrode was implanted on the sciatic nerve of a rat. It comprised four rings (1 mm apart), each containing four circumferentially arranged electrodes. Temporally-patterned pairs of electrical stimuli were delivered through all 120 combinations of electrode pairs. Compound action potentials, elicited by stimulation of the sciatic nerve, were measured with two pairs of hook electrodes placed on the L4 dorsal root. We find that regardless of the relative position of the two electrodes on the cuff, at an interval of 0 ms, the CAP response is facilitated. At all other intervals, an inter-stimulus interval of even 5 ms was not enough for the response to the second stimulus to fully recover. This observation suggests that overlapping regions of nerve were stimulated. Examining only the intervals where the CAP did not fully recover, we noticed that if the electrodes lay longitudinally, that is, along the nerve, the CAP recovery was significantly impaired, compared to when the electrodes were in any other relative position. The observed space- and time-dependent interactions advocate for further controlled neuroscience studies in parallel to translational work on closed-loop prosthesis control.
Collapse
|
9
|
Black BJ, Kanneganti A, Joshi-Imre A, Rihani R, Chakraborty B, Abbott J, Pancrazio JJ, Cogan SF. Chronic recording and electrochemical performance of Utah microelectrode arrays implanted in rat motor cortex. J Neurophysiol 2018; 120:2083-2090. [PMID: 30020844 DOI: 10.1152/jn.00181.2018] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Multisite implantable electrode arrays serve as a tool to understand cortical network connectivity and plasticity. Furthermore, they enable electrical stimulation to drive plasticity, study motor/sensory mapping, or provide network input for controlling brain-computer interfaces. Neurobehavioral rodent models are prevalent in studies of motor cortex injury and recovery as well as restoration of auditory/visual cues due to their relatively low cost and ease of training. Therefore, it is important to understand the chronic performance of relevant electrode arrays in rodent models. In this report, we evaluate the chronic recording and electrochemical performance of 16-channel Utah electrode arrays, the current state-of-the-art in pre-/clinical cortical recording and stimulation, in rat motor cortex over a period of 6 mo. The single-unit active electrode yield decreased from 52.8 ± 10.0 ( week 1) to 13.4 ± 5.1% ( week 24). Similarly, the total number of single units recorded on all electrodes across all arrays decreased from 106 to 15 over the same time period. Parallel measurements of electrochemical impedance spectra and cathodic charge storage capacity exhibited significant changes in electrochemical characteristics consistent with development of electrolyte leakage pathways over time. Additionally, measurements of maximum cathodal potential excursion indicated that only a relatively small fraction of electrodes (10-35% at 1 and 24 wk postimplantation) were capable of delivering relevant currents (20 µA at 4 nC/ph) without exceeding negative or positive electrochemical potential limits. In total, our findings suggest mainly abiotic failure modes, including mechanical wire breakage as well as degradation of conducting and insulating substrates. NEW & NOTEWORTHY Multisite implantable electrode arrays serve as a tool to record cortical network activity and enable electrical stimulation to drive plasticity or provide network feedback. The use of rodent models in these fields is prevalent. We evaluated chronic recording and electrochemical performance of 16-channel Utah electrode arrays in rat motor cortex over a period of 6 mo. We primarily observed abiotic failure modes suggestive of mechanical wire breakage and/or degradation of insulation.
Collapse
Affiliation(s)
- Bryan J Black
- Department of Bioengineering, The University of Texas at Dallas , Richardson, Texas
| | - Aswini Kanneganti
- Department of Bioengineering, The University of Texas at Dallas , Richardson, Texas
| | - Alexandra Joshi-Imre
- Department of Bioengineering, The University of Texas at Dallas , Richardson, Texas
| | - Rashed Rihani
- Department of Bioengineering, The University of Texas at Dallas , Richardson, Texas
| | - Bitan Chakraborty
- Department of Bioengineering, The University of Texas at Dallas , Richardson, Texas
| | - Justin Abbott
- Department of Bioengineering, The University of Texas at Dallas , Richardson, Texas
| | - Joseph J Pancrazio
- Department of Bioengineering, The University of Texas at Dallas , Richardson, Texas
| | - Stuart F Cogan
- Department of Bioengineering, The University of Texas at Dallas , Richardson, Texas
| |
Collapse
|
10
|
Zhou A, Johnson BC, Muller R. Toward true closed-loop neuromodulation: artifact-free recording during stimulation. Curr Opin Neurobiol 2018; 50:119-127. [DOI: 10.1016/j.conb.2018.01.012] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Revised: 01/12/2018] [Accepted: 01/17/2018] [Indexed: 11/29/2022]
|
11
|
Du ZJ, Kolarcik CL, Kozai TDY, Luebben SD, Sapp SA, Zheng XS, Nabity JA, Cui XT. Ultrasoft microwire neural electrodes improve chronic tissue integration. Acta Biomater 2017; 53:46-58. [PMID: 28185910 DOI: 10.1016/j.actbio.2017.02.010] [Citation(s) in RCA: 109] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2016] [Revised: 02/02/2017] [Accepted: 02/05/2017] [Indexed: 12/11/2022]
Abstract
Chronically implanted neural multi-electrode arrays (MEA) are an essential technology for recording electrical signals from neurons and/or modulating neural activity through stimulation. However, current MEAs, regardless of the type, elicit an inflammatory response that ultimately leads to device failure. Traditionally, rigid materials like tungsten and silicon have been employed to interface with the relatively soft neural tissue. The large stiffness mismatch is thought to exacerbate the inflammatory response. In order to minimize the disparity between the device and the brain, we fabricated novel ultrasoft electrodes consisting of elastomers and conducting polymers with mechanical properties much more similar to those of brain tissue than previous neural implants. In this study, these ultrasoft microelectrodes were inserted and released using a stainless steel shuttle with polyethyleneglycol (PEG) glue. The implanted microwires showed functionality in acute neural stimulation. When implanted for 1 or 8weeks, the novel soft implants demonstrated significantly reduced inflammatory tissue response at week 8 compared to tungsten wires of similar dimension and surface chemistry. Furthermore, a higher degree of cell body distortion was found next to the tungsten implants compared to the polymer implants. Our results support the use of these novel ultrasoft electrodes for long term neural implants. STATEMENT OF SIGNIFICANCE One critical challenge to the translation of neural recording/stimulation electrode technology to clinically viable devices for brain computer interface (BCI) or deep brain stimulation (DBS) applications is the chronic degradation of device performance due to the inflammatory tissue reaction. While many hypothesize that soft and flexible devices elicit reduced inflammatory tissue responses, there has yet to be a rigorous comparison between soft and stiff implants. We have developed an ultra-soft microelectrode with Young's modulus lower than 1MPa, closely mimicking the brain tissue modulus. Here, we present a rigorous histological comparison of this novel ultrasoft electrode and conventional stiff electrode with the same size, shape and surface chemistry, implanted in rat brains for 1-week and 8-weeks. Significant improvement was observed for ultrasoft electrodes, including inflammatory tissue reaction, electrode-tissue integration as well as mechanical disturbance to nearby neurons. A full spectrum of new techniques were developed in this study, from insertion shuttle to in situ sectioning of the microelectrode to automated cell shape analysis, all of which should contribute new methods to the field. Finally, we showed the electrical functionality of the ultrasoft electrode, demonstrating the potential of flexible neural implant devices for future research and clinical use.
Collapse
Affiliation(s)
- Zhanhong Jeff Du
- Department of Bioengineering, University of Pittsburgh, PA, USA; Center for the Neural Basis of Cognition, University of Pittsburgh, PA, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, PA, USA; Shenzhen Key Lab of Neuropsychiatric Modulation, CAS Center for Excellence in Brain Science, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Christi L Kolarcik
- Department of Bioengineering, University of Pittsburgh, PA, USA; Center for the Neural Basis of Cognition, University of Pittsburgh, PA, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, PA, USA; Systems Neuroscience Institute, University of Pittsburgh, PA, USA
| | - Takashi D Y Kozai
- Department of Bioengineering, University of Pittsburgh, PA, USA; Center for the Neural Basis of Cognition, University of Pittsburgh, PA, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, PA, USA; NeuroTech Center of Brain Institute, University of Pittsburgh, PA, USA
| | | | | | - Xin Sally Zheng
- Department of Bioengineering, University of Pittsburgh, PA, USA
| | - James A Nabity
- Department of Aerospace Engineering Sciences, University of Colorado, Boulder, CO,USA
| | - X Tracy Cui
- Department of Bioengineering, University of Pittsburgh, PA, USA; Center for the Neural Basis of Cognition, University of Pittsburgh, PA, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, PA, USA.
| |
Collapse
|
12
|
Navarrete M, Pyrzowski J, Corlier J, Valderrama M, Le Van Quyen M. Automated detection of high-frequency oscillations in electrophysiological signals: Methodological advances. ACTA ACUST UNITED AC 2017; 110:316-326. [PMID: 28235667 DOI: 10.1016/j.jphysparis.2017.02.003] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 01/31/2017] [Accepted: 02/19/2017] [Indexed: 01/17/2023]
Abstract
In recent years, new recording technologies have advanced such that oscillations of neuronal networks can be identified from simultaneous, multisite recordings at high temporal and spatial resolutions. However, because of the deluge of multichannel data generated by these experiments, achieving the full potential of parallel neuronal recordings also depends on the development of new mathematical methods capable of extracting meaningful information related to time, frequency and space. In this review, we aim to bridge this gap by focusing on the new analysis tools developed for the automated detection of high-frequency oscillations (HFOs, >40Hz) in local field potentials. For this, we provide a revision of different aspects associated with physiological and pathological HFOs as well as the several stages involved in their automatic detection including preprocessing, selection, rejection and analysis through time-frequency processes. Beyond basic research, the automatic detection of HFOs would greatly assist diagnosis of epilepsy disorders based on the recognition of these typical pathological patterns in the electroencephalogram (EEG). Also, we emphasize how these HFO detection methods can be applied and the properties that might be inferred from neuronal signals, indicating potential future directions.
Collapse
Affiliation(s)
- Miguel Navarrete
- Department of Biomedical Engineering, University of Los Andes, Bogotá D.C., Colombia
| | - Jan Pyrzowski
- Institut du Cerveau et de la Moelle Epinière, UMR S 1127, CNRS UMR 7225, Hôpital de la Pitié-Salpêtrière, Paris, France
| | - Juliana Corlier
- Institut du Cerveau et de la Moelle Epinière, UMR S 1127, CNRS UMR 7225, Hôpital de la Pitié-Salpêtrière, Paris, France
| | - Mario Valderrama
- Department of Biomedical Engineering, University of Los Andes, Bogotá D.C., Colombia
| | - Michel Le Van Quyen
- Institut du Cerveau et de la Moelle Epinière, UMR S 1127, CNRS UMR 7225, Hôpital de la Pitié-Salpêtrière, Paris, France.
| |
Collapse
|
13
|
Vasudevan S, Patel K, Welle C. Rodent model for assessing the long term safety and performance of peripheral nerve recording electrodes. J Neural Eng 2016; 14:016008. [PMID: 27934777 DOI: 10.1088/1741-2552/14/1/016008] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE In the US alone, there are approximately 185 000 cases of limb amputation annually, which can reduce the quality of life for those individuals. Current prosthesis technology could be improved by access to signals from the nervous system for intuitive prosthesis control. After amputation, residual peripheral nerves continue to convey motor signals and electrical stimulation of these nerves can elicit sensory percepts. However, current technology for extracting information directly from peripheral nerves has limited chronic reliability, and novel approaches must be vetted to ensure safe long-term use. The present study aims to optimize methods to establish a test platform using rodent model to assess the long term safety and performance of electrode interfaces implanted in the peripheral nerves. APPROACH Floating Microelectrode Arrays (FMA, Microprobes for Life Sciences) were implanted into the rodent sciatic nerve. Weekly in vivo recordings and impedance measurements were performed in animals to assess performance and physical integrity of electrodes. Motor (walking track analysis) and sensory (Von Frey) function tests were used to assess change in nerve function due to the implant. Following the terminal recording session, the nerve was explanted and the health of axons, myelin and surrounding tissues were assessed using immunohistochemistry (IHC). The explanted electrodes were visualized under high magnification using scanning electrode microscopy (SEM) to observe any physical damage. MAIN RESULTS Recordings of axonal action potentials demonstrated notable session-to-session variability. Impedance of the electrodes increased upon implantation and displayed relative stability until electrode failure. Initial deficits in motor function recovered by 2 weeks, while sensory deficits persisted through 6 weeks of assessment. The primary cause of failure was identified as lead wire breakage in all of animals. IHC indicated myelinated and unmyelinated axons near the implanted electrode shanks, along with dense cellular accumulations near the implant site. Scanning electron microscopy (SEM) showed alterations of the electrode insulation and deformation of electrode shanks. SIGNIFICANCE We describe a comprehensive testing platform with applicability to electrodes that record from the peripheral nerves. This study assesses the long term safety and performance of electrodes in the peripheral nerves using a rodent model. Under this animal test platform, FMA electrodes record single unit action potentials but have limited chronic reliability due to structural weaknesses. Future work will apply these methods to other commercially-available and novel peripheral electrode technologies.
Collapse
Affiliation(s)
- Srikanth Vasudevan
- Division of Biomedical Physics, Office of Science and Engineering Laboratory, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, USA
| | | | | |
Collapse
|
14
|
Brandli A, Luu CD, Guymer RH, Ayton LN. Progress in the clinical development and utilization of vision prostheses: an update. Eye Brain 2016; 8:15-25. [PMID: 28539798 PMCID: PMC5398739 DOI: 10.2147/eb.s70822] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Vision prostheses, or "bionic eyes", are implantable medical bionic devices with the potential to restore rudimentary sight to people with profound vision loss or blindness. In the past two decades, this field has rapidly progressed, and there are now two commercially available retinal prostheses in the US and Europe, and a number of next-generation devices in development. This review provides an update on the development of these devices and a discussion on the future directions for the field.
Collapse
Affiliation(s)
- Alice Brandli
- Centre for Eye Research Australia, Department of Surgery (Ophthalmology), The University of Melbourne, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Chi D Luu
- Centre for Eye Research Australia, Department of Surgery (Ophthalmology), The University of Melbourne, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Robyn H Guymer
- Centre for Eye Research Australia, Department of Surgery (Ophthalmology), The University of Melbourne, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Lauren N Ayton
- Centre for Eye Research Australia, Department of Surgery (Ophthalmology), The University of Melbourne, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| |
Collapse
|
15
|
Etemadi L, Mohammed M, Thorbergsson PT, Ekstrand J, Friberg A, Granmo M, Pettersson LME, Schouenborg J. Embedded Ultrathin Cluster Electrodes for Long-Term Recordings in Deep Brain Centers. PLoS One 2016; 11:e0155109. [PMID: 27159159 PMCID: PMC4861347 DOI: 10.1371/journal.pone.0155109] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Accepted: 04/25/2016] [Indexed: 01/03/2023] Open
Abstract
Neural interfaces which allow long-term recordings in deep brain structures in awake freely moving animals have the potential of becoming highly valuable tools in neuroscience. However, the recording quality usually deteriorates over time, probably at least partly due to tissue reactions caused by injuries during implantation, and subsequently micro-forces due to a lack of mechanical compliance between the tissue and neural interface. To address this challenge, we developed a gelatin embedded neural interface comprising highly flexible electrodes and evaluated its long term recording properties. Bundles of ultrathin parylene C coated platinum electrodes (N = 29) were embedded in a hard gelatin based matrix shaped like a needle, and coated with Kollicoat™ to retard dissolution of gelatin during the implantation. The implantation parameters were established in an in vitro model of the brain (0.5% agarose). Following a craniotomy in the anesthetized rat, the gelatin embedded electrodes were stereotactically inserted to a pre-target position, and after gelatin dissolution the electrodes were further advanced and spread out in the area of the subthalamic nucleus (STN). The performance of the implanted electrodes was evaluated under anesthesia, during 8 weeks. Apart from an increase in the median-noise level during the first 4 weeks, the electrode impedance and signal-to-noise ratio of single-units remained stable throughout the experiment. Histological postmortem analysis confirmed implantation in the area of STN in most animals. In conclusion, by combining novel biocompatible implantation techniques and ultra-flexible electrodes, long-term neuronal recordings from deep brain structures with no significant deterioration of electrode function were achieved.
Collapse
Affiliation(s)
- Leila Etemadi
- Neuronano Research Center, Department of Experimental Medical Science, Lund University, Lund, Sweden
| | - Mohsin Mohammed
- Neuronano Research Center, Department of Experimental Medical Science, Lund University, Lund, Sweden
- * E-mail: (MM); (JS); (LP)
| | - Palmi Thor Thorbergsson
- Neuronano Research Center, Department of Experimental Medical Science, Lund University, Lund, Sweden
| | - Joakim Ekstrand
- Neuronano Research Center, Department of Experimental Medical Science, Lund University, Lund, Sweden
| | - Annika Friberg
- Neuronano Research Center, Department of Experimental Medical Science, Lund University, Lund, Sweden
| | - Marcus Granmo
- Neuronano Research Center, Department of Experimental Medical Science, Lund University, Lund, Sweden
| | - Lina M. E. Pettersson
- Neuronano Research Center, Department of Experimental Medical Science, Lund University, Lund, Sweden
- * E-mail: (MM); (JS); (LP)
| | - Jens Schouenborg
- Neuronano Research Center, Department of Experimental Medical Science, Lund University, Lund, Sweden
- * E-mail: (MM); (JS); (LP)
| |
Collapse
|
16
|
Lewis PM, Thomson RH, Rosenfeld JV, Fitzgerald PB. Brain Neuromodulation Techniques. Neuroscientist 2016; 22:406-21. [DOI: 10.1177/1073858416646707] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The modulation of brain function via the application of weak direct current was first observed directly in the early 19th century. In the past 3 decades, transcranial magnetic stimulation and deep brain stimulation have undergone clinical translation, offering alternatives to pharmacological treatment of neurological and neuropsychiatric disorders. Further development of novel neuromodulation techniques employing ultrasound, micro-scale magnetic fields and optogenetics is being propelled by a rapidly improving understanding of the clinical and experimental applications of artificially stimulating or depressing brain activity in human health and disease. With the current rapid growth in neuromodulation technologies and applications, it is timely to review the genesis of the field and the current state of the art in this area.
Collapse
Affiliation(s)
- Philip M. Lewis
- Department of Neurosurgery, Alfred Hospital, Melbourne, Victoria, Australia
- Department of Surgery, Central Clinical School, Monash University, Clayton, Victoria, Australia
- Monash Institute of Medical Engineering, Monash University, Clayton, Victoria, Australia
| | - Richard H. Thomson
- Monash Institute of Medical Engineering, Monash University, Clayton, Victoria, Australia
- Monash Alfred Psychiatry Research Centre, Central Clinical School, Monash University, Melbourne, Victoria, Australia
| | - Jeffrey V. Rosenfeld
- Department of Neurosurgery, Alfred Hospital, Melbourne, Victoria, Australia
- Department of Surgery, Central Clinical School, Monash University, Clayton, Victoria, Australia
- Monash Institute of Medical Engineering, Monash University, Clayton, Victoria, Australia
- F. Edward Hébert School of Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| | - Paul B. Fitzgerald
- Monash Institute of Medical Engineering, Monash University, Clayton, Victoria, Australia
- Monash Alfred Psychiatry Research Centre, Central Clinical School, Monash University, Melbourne, Victoria, Australia
| |
Collapse
|
17
|
Meijs S, Fjorback M, Jensen C, Sørensen S, Rechendorff K, Rijkhoff NJM. Influence of fibrous encapsulation on electro-chemical properties of TiN electrodes. Med Eng Phys 2016; 38:468-76. [PMID: 26997562 DOI: 10.1016/j.medengphy.2016.02.010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2015] [Revised: 02/10/2016] [Accepted: 02/16/2016] [Indexed: 10/22/2022]
Abstract
The aim of this study was to investigate how the electrochemical properties of porous titanium nitride stimulation electrode are affected by fibrous encapsulation in vivo. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry and voltage transient (VT) measurements were performed in vivo and in phosphate buffered saline, where the encapsulation process is absent. EIS was used as a non-invasive measurement to follow the inflammation, healing and encapsulation process. EIS showed that the healing and encapsulation process lasted 3-4 weeks. The VTs increased during the first 3-4 weeks, after which they stabilized. The charge storage capacity (CSC) decreased most during the first 3-4 weeks. The increasing VTs and decreasing CSC during the first 3-4 weeks after implantation of the in vivo electrodes seem related to healing and fibrous encapsulation. It is suggested that the charge injection pathway during the encapsulation process changes, which implies that charge injection limits are underestimated with conventional methods.
Collapse
Affiliation(s)
- Suzan Meijs
- Center for Sensory-Motor Interaction, Aalborg University, Fredrik Bajersvej 7E, 9220 Aalborg, Denmark.
| | - Morten Fjorback
- Neurodan A/S, Aalborg, Denmark; Bang & Olufsen Medicom A/S, Struer, Denmark
| | - Carina Jensen
- Neurodan A/S, Aalborg, Denmark; Aalborg University Hospital, Aalborg, Denmark
| | | | | | - Nico J M Rijkhoff
- Center for Sensory-Motor Interaction, Aalborg University, Fredrik Bajersvej 7E, 9220 Aalborg, Denmark
| |
Collapse
|
18
|
Arreaga-Salas DE, Avendaño-Bolívar A, Simon D, Reit R, Garcia-Sandoval A, Rennaker RL, Voit W. Integration of High-Charge-Injection-Capacity Electrodes onto Polymer Softening Neural Interfaces. ACS APPLIED MATERIALS & INTERFACES 2015; 7:26614-23. [PMID: 26575084 DOI: 10.1021/acsami.5b08139] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Softening neural interfaces are implanted stiff to enable precise insertion, and they soften in physiological conditions to minimize modulus mismatch with tissue. In this work, a high-charge-injection-capacity iridium electrode fabrication process is detailed. For the first time, this process enables integration of iridium electrodes onto softening substrates using photolithography to define all features in the device. Importantly, no electroplated layers are utilized, leading to a highly scalable method for consistent device fabrication. The iridium electrode is metallically bonded to the gold conductor layer, which is covalently bonded to the softening substrate via sulfur-based click chemistry. The resulting shape-memory polymer neural interfaces can deliver more than 2 billion symmetric biphasic pulses (100 μs/phase), with a charge of 200 μC/cm(2) and geometric surface area (GSA) of 300 μm(2). A transfer-by-polymerization method is used in combination with standard semiconductor processing techniques to fabricate functional neural probes onto a thiol-ene-based, thin film substrate. Electrical stability is tested under simulated physiological conditions in an accelerated electrical aging paradigm with periodic measurement of electrochemical impedance spectra (EIS) and charge storage capacity (CSC) at various intervals. Electrochemical characterization and both optical and scanning electron microscopy suggest significant breakdown of the 600 nm-thick parylene-C insulation, although no delamination of the conductors or of the final electrode interface was observed. Minor cracking at the edges of the thin film iridium electrodes was occasionally observed. The resulting devices will provide electrical recording and stimulation of the nervous system to better understand neural wiring and timing, to target treatments for debilitating diseases, and to give neuroscientists spatially selective and specific tools to interact with the body. This approach has uses for cochlear implants, nerve cuff electrodes, penetrating cortical probes, spinal stimulators, blanket electrodes for the gut, stomach, and visceral organs and a host of other custom nerve-interfacing devices.
Collapse
Affiliation(s)
- David E Arreaga-Salas
- Department of Materials Science and Engineering, ‡Department of Bioengineering, and §Department of Mechanical Engineering, The University of Texas at Dallas , 800 West Campbell Road, Richardson, Texas 75080-3021, United States
| | - Adrian Avendaño-Bolívar
- Department of Materials Science and Engineering, ‡Department of Bioengineering, and §Department of Mechanical Engineering, The University of Texas at Dallas , 800 West Campbell Road, Richardson, Texas 75080-3021, United States
| | - Dustin Simon
- Department of Materials Science and Engineering, ‡Department of Bioengineering, and §Department of Mechanical Engineering, The University of Texas at Dallas , 800 West Campbell Road, Richardson, Texas 75080-3021, United States
| | - Radu Reit
- Department of Materials Science and Engineering, ‡Department of Bioengineering, and §Department of Mechanical Engineering, The University of Texas at Dallas , 800 West Campbell Road, Richardson, Texas 75080-3021, United States
| | - Aldo Garcia-Sandoval
- Department of Materials Science and Engineering, ‡Department of Bioengineering, and §Department of Mechanical Engineering, The University of Texas at Dallas , 800 West Campbell Road, Richardson, Texas 75080-3021, United States
| | - Robert L Rennaker
- Department of Materials Science and Engineering, ‡Department of Bioengineering, and §Department of Mechanical Engineering, The University of Texas at Dallas , 800 West Campbell Road, Richardson, Texas 75080-3021, United States
| | - Walter Voit
- Department of Materials Science and Engineering, ‡Department of Bioengineering, and §Department of Mechanical Engineering, The University of Texas at Dallas , 800 West Campbell Road, Richardson, Texas 75080-3021, United States
| |
Collapse
|
19
|
Brunton EK, Winther-Jensen B, Wang C, Yan EB, Hagh Gooie S, Lowery AJ, Rajan R. In vivo comparison of the charge densities required to evoke motor responses using novel annular penetrating microelectrodes. FRONTIERS IN NEUROENGINEERING 2015; 8:5. [PMID: 26029097 PMCID: PMC4429246 DOI: 10.3389/fneng.2015.00005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2015] [Accepted: 04/17/2015] [Indexed: 11/13/2022]
Abstract
Electrodes for cortical stimulation need to deliver current to neural tissue effectively and safely. We have developed electrodes with a novel annular geometry for use in cortical visual prostheses. Here, we explore a critical question on the ideal annulus height to ensure electrical stimulation will be safe and effective. We implanted single electrodes into the motor cortex of anesthetized rats and measured the current required to evoke a motor response to stimulation, and the charge injection capacity (CIC) of the electrodes. We compared platinum iridium (PtIr) electrodes with different annulus heights, with and without a coating of porous titanium nitride (TiN). Threshold charge densities to evoke a motor response ranged from 12 to 36 μC.cm-2.ph-1. Electrodes with larger geometric surface areas (GSAs) required higher currents to evoke responses, but lower charge densities. The addition of a porous TiN coating did not significantly influence the current required to evoke a motor response. The CIC of both electrode types was significantly reduced in vivo compared with in vitro measurements. The measured CIC was 72 and 18 μC.cm-2.ph-1 for electrodes with and without a TiN coating, respectively. These results support the use of PtIr annular electrodes with annulus heights greater than 100 μm (GSA of 38, 000 μm2). However, if the electrodes are coated with porous TiN the annulus height can be reduced to 40 μm (GSA of 16,000 μm2).
Collapse
Affiliation(s)
- Emma K Brunton
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Electrical and Computer Systems Engineering, Monash University Clayton, VIC, Australia ; Department of Physiology, Monash University Clayton, VIC, Australia
| | | | - Chun Wang
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Physiology, Monash University Clayton, VIC, Australia
| | - Edwin B Yan
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Physiology, Monash University Clayton, VIC, Australia
| | - Saman Hagh Gooie
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Physiology, Monash University Clayton, VIC, Australia
| | - Arthur J Lowery
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Electrical and Computer Systems Engineering, Monash University Clayton, VIC, Australia
| | - Ramesh Rajan
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Physiology, Monash University Clayton, VIC, Australia
| |
Collapse
|
20
|
Brunton EK, Winther-Jensen B, Wang C, Yan EB, Hagh Gooie S, Lowery AJ, Rajan R. In vivo comparison of the charge densities required to evoke motor responses using novel annular penetrating microelectrodes. Front Neurosci 2015; 9:265. [PMID: 26283905 PMCID: PMC4518750 DOI: 10.3389/fnins.2015.00265] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2015] [Accepted: 04/17/2015] [Indexed: 11/30/2022] Open
Abstract
Electrodes for cortical stimulation need to deliver current to neural tissue effectively and safely. We have developed electrodes with a novel annular geometry for use in cortical visual prostheses. Here, we explore a critical question on the ideal annulus height to ensure electrical stimulation will be safe and effective. We implanted single electrodes into the motor cortex of anesthetized rats and measured the current required to evoke a motor response to stimulation, and the charge injection capacity (CIC) of the electrodes. We compared platinum iridium (PtIr) electrodes with different annulus heights, with and without a coating of porous titanium nitride (TiN). Threshold charge densities to evoke a motor response ranged from 12 to 36 μC.cm-2.ph-1. Electrodes with larger geometric surface areas (GSAs) required higher currents to evoke responses, but lower charge densities. The addition of a porous TiN coating did not significantly influence the current required to evoke a motor response. The CIC of both electrode types was significantly reduced in vivo compared with in vitro measurements. The measured CIC was 72 and 18 μC.cm-2.ph-1 for electrodes with and without a TiN coating, respectively. These results support the use of PtIr annular electrodes with annulus heights greater than 100 μm (GSA of 38, 000 μm2). However, if the electrodes are coated with porous TiN the annulus height can be reduced to 40 μm (GSA of 16,000 μm2).
Collapse
Affiliation(s)
- Emma K Brunton
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Electrical and Computer Systems Engineering, Monash University Clayton, VIC, Australia ; Department of Physiology, Monash University Clayton, VIC, Australia
| | | | - Chun Wang
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Physiology, Monash University Clayton, VIC, Australia
| | - Edwin B Yan
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Physiology, Monash University Clayton, VIC, Australia
| | - Saman Hagh Gooie
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Physiology, Monash University Clayton, VIC, Australia
| | - Arthur J Lowery
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Electrical and Computer Systems Engineering, Monash University Clayton, VIC, Australia
| | - Ramesh Rajan
- Monash Vision Group, Monash University Clayton, VIC, Australia ; Department of Physiology, Monash University Clayton, VIC, Australia
| |
Collapse
|
21
|
Lewis PM, Ackland HM, Lowery AJ, Rosenfeld JV. Restoration of vision in blind individuals using bionic devices: a review with a focus on cortical visual prostheses. Brain Res 2014; 1595:51-73. [PMID: 25446438 DOI: 10.1016/j.brainres.2014.11.020] [Citation(s) in RCA: 114] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2014] [Revised: 11/05/2014] [Accepted: 11/08/2014] [Indexed: 12/13/2022]
Abstract
The field of neurobionics offers hope to patients with sensory and motor impairment. Blindness is a common cause of major sensory loss, with an estimated 39 million people worldwide suffering from total blindness in 2010. Potential treatment options include bionic devices employing electrical stimulation of the visual pathways. Retinal stimulation can restore limited visual perception to patients with retinitis pigmentosa, however loss of retinal ganglion cells precludes this approach. The optic nerve, lateral geniculate nucleus and visual cortex provide alternative stimulation targets, with several research groups actively pursuing a cortically-based device capable of driving several hundred stimulating electrodes. While great progress has been made since the earliest works of Brindley and Dobelle in the 1960s and 1970s, significant clinical, surgical, psychophysical, neurophysiological, and engineering challenges remain to be overcome before a commercially-available cortical implant will be realized. Selection of candidate implant recipients will require assessment of their general, psychological and mental health, and likely responses to visual cortex stimulation. Implant functionality, longevity and safety may be enhanced by careful electrode insertion, optimization of electrical stimulation parameters and modification of immune responses to minimize or prevent the host response to the implanted electrodes. Psychophysical assessment will include mapping the positions of potentially several hundred phosphenes, which may require repetition if electrode performance deteriorates over time. Therefore, techniques for rapid psychophysical assessment are required, as are methods for objectively assessing the quality of life improvements obtained from the implant. These measures must take into account individual differences in image processing, phosphene distribution and rehabilitation programs that may be required to optimize implant functionality. In this review, we detail these and other challenges facing developers of cortical visual prostheses in addition to briefly outlining the epidemiology of blindness, and the history of cortical electrical stimulation in the context of visual prosthetics.
Collapse
Affiliation(s)
- Philip M Lewis
- Department of Neurosurgery, Alfred Hospital, Melbourne, Australia; Department of Surgery, Monash University, Central Clinical School, Melbourne, Australia; Monash Vision Group, Faculty of Engineering, Monash University, Melbourne, Australia; Monash Institute of Medical Engineering, Monash University, Melbourne, Australia.
| | - Helen M Ackland
- Department of Neurosurgery, Alfred Hospital, Melbourne, Australia; Department of Epidemiology and Preventive Medicine, Monash University, Melbourne, Australia.
| | - Arthur J Lowery
- Monash Vision Group, Faculty of Engineering, Monash University, Melbourne, Australia; Monash Institute of Medical Engineering, Monash University, Melbourne, Australia; Department of Electrical and Computer Systems Engineering, Faculty of Engineering, Monash University, Melbourne, Australia.
| | - Jeffrey V Rosenfeld
- Department of Neurosurgery, Alfred Hospital, Melbourne, Australia; Department of Surgery, Monash University, Central Clinical School, Melbourne, Australia; Monash Vision Group, Faculty of Engineering, Monash University, Melbourne, Australia; Monash Institute of Medical Engineering, Monash University, Melbourne, Australia; F. Edward Hébert School of Medicine, Uniformed Services University of the Health Sciences, Bethesda, USA.
| |
Collapse
|
22
|
Chen KH, Dammann JF, Boback JL, Tenore FV, Otto KJ, Gaunt RA, Bensmaia SJ. The effect of chronic intracortical microstimulation on the electrode-tissue interface. J Neural Eng 2014; 11:026004. [PMID: 24503702 PMCID: PMC8129589 DOI: 10.1088/1741-2560/11/2/026004] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Somatosensation is critical for effective object manipulation, but current upper limb prostheses do not provide such feedback to the user. For individuals who require use of prosthetic limbs, this lack of feedback transforms a mundane task into one that requires extreme concentration and effort. Although vibrotactile motors and sensory substitution devices can be used to convey gross sensations, a direct neural interface is required to provide detailed and intuitive sensory feedback. The viability of intracortical microstimulation (ICMS) as a method to deliver feedback depends in part on the long-term reliability of implanted electrodes used to deliver the stimulation. The objective of the present study is to investigate the effects of chronic ICMS on the electrode-tissue interface. APPROACH We stimulate the primary somatosensory cortex of three Rhesus macaques through chronically implanted electrodes for 4 h per day over a period of six months, with different electrodes subjected to different regimes of stimulation. We measure the impedance and voltage excursion as a function of time and of ICMS parameters. We also test the sensorimotor consequences of chronic ICMS by having animals grasp and manipulate small treats. MAIN RESULTS We show that impedance and voltage excursion both decay with time but stabilize after 10-12 weeks. The magnitude of this decay is dependent on the amplitude of the ICMS and, to a lesser degree, the duration of individual pulse trains. Furthermore, chronic ICMS does not produce any deficits in fine motor control. SIGNIFICANCE The results suggest that chronic ICMS has only a minor effect on the electrode-tissue interface and may thus be a viable means to convey sensory feedback in neuroprosthetics.
Collapse
Affiliation(s)
- Kevin H Chen
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, IL, USA
| | | | | | | | | | | | | |
Collapse
|