1
|
Azrad Leibovitch T, Farah N, Markus A, Mandel Y. A novel GCaMP6f-RCS rat model for studying electrical stimulation in the degenerated retina. Front Cell Dev Biol 2024; 12:1386141. [PMID: 38711618 PMCID: PMC11070775 DOI: 10.3389/fcell.2024.1386141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Accepted: 03/25/2024] [Indexed: 05/08/2024] Open
Abstract
Background: Retinal prostheses aim to restore vision by electrically stimulating the remaining viable retinal cells in Retinal Degeneration (RD) cases. Research in this field necessitates a comprehensive analysis of retinal ganglion cells' (RGCs) responses to assess the obtained visual acuity and quality. Here we present a novel animal model which facilitates the optical recording of RGCs activity in an RD rat. This model can significantly enhance the functional evaluation of vision restoration treatments. Methods: The development of the novel rat model is based on crossbreeding a retinal degenerated Royal College of Surgeons (RCS) rat with a transgenic line expressing the genetic calcium indicator GCaMP6f in the RGCs. Characterization of the model was achieved using Optical Coherence Tomography (OCT) imaging, histology, and electroretinography (ERG) at the ages of 4, 8, and 12 weeks. Additionally, optical recordings of RGCs function in response to ex-vivo subretinal electrical stimulations were performed. Results: Histological investigations confirmed the high expression of GCaMP6f in the RGCs and minimal expression in the inner nuclear layer (INL). OCT imaging and histological studies revealed the expected gradual retinal degeneration, as evident by the decrease in retinal thickness with age and the formation of subretinal debris. This degeneration was further confirmed by ERG recordings, which demonstrated a significant decrease in the b-wave amplitude throughout the degeneration process, culminating in its absence at 12 weeks in the GCaMP6f-RCS rat. Importantly, the feasibility of investigating subretinal stimulation was demonstrated, revealing a consistent increase in activation threshold throughout degeneration. Furthermore, an increase in the diameter of the activated area with increasing currents was observed. The spatial spread of the activation area in the GCaMP6f-RCS rat was found to be smaller and exhibited faster activation dynamics compared with the GCaMP6f-LE strain. Conclusion: This novel animal model offers an opportunity to deepen our understanding of prosthetically induced retinal responses, potentially leading to significant advancements in prosthetic interventions in visual impairments.
Collapse
Affiliation(s)
- Tamar Azrad Leibovitch
- Bar Ilan Institute for Nanotechnology and Advanced Materials (BINA), Bar Ilan University, Ramat Gan, Israel
- Faculty of Life Sciences, School of Optometry and Visual Science, Bar Ilan University, Ramat Gan, Israel
| | - Nairouz Farah
- Bar Ilan Institute for Nanotechnology and Advanced Materials (BINA), Bar Ilan University, Ramat Gan, Israel
- Faculty of Life Sciences, School of Optometry and Visual Science, Bar Ilan University, Ramat Gan, Israel
| | - Amos Markus
- Bar Ilan Institute for Nanotechnology and Advanced Materials (BINA), Bar Ilan University, Ramat Gan, Israel
- Faculty of Life Sciences, School of Optometry and Visual Science, Bar Ilan University, Ramat Gan, Israel
| | - Yossi Mandel
- Bar Ilan Institute for Nanotechnology and Advanced Materials (BINA), Bar Ilan University, Ramat Gan, Israel
- Faculty of Life Sciences, School of Optometry and Visual Science, Bar Ilan University, Ramat Gan, Israel
| |
Collapse
|
2
|
Corna A, Cojocaru AE, Bui MT, Werginz P, Zeck G. Avoidance of axonal stimulation with sinusoidal epiretinal stimulation. J Neural Eng 2024; 21:026036. [PMID: 38547529 DOI: 10.1088/1741-2552/ad38de] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 03/28/2024] [Indexed: 04/11/2024]
Abstract
Objective.Neuromodulation, particularly electrical stimulation, necessitates high spatial resolution to achieve artificial vision with high acuity. In epiretinal implants, this is hindered by the undesired activation of distal axons. Here, we investigate focal and axonal activation of retinal ganglion cells (RGCs) in epiretinal configuration for different sinusoidal stimulation frequencies.Approach.RGC responses to epiretinal sinusoidal stimulation at frequencies between 40 and 100 Hz were tested inex-vivophotoreceptor degenerated (rd10) isolated retinae. Experiments were conducted using a high-density CMOS-based microelectrode array, which allows to localize RGC cell bodies and axons at high spatial resolution.Main results.We report current and charge density thresholds for focal and distal axon activation at stimulation frequencies of 40, 60, 80, and 100 Hz for an electrode size with an effective area of 0.01 mm2. Activation of distal axons is avoided up to a stimulation amplitude of 0.23µA (corresponding to 17.3µC cm-2) at 40 Hz and up to a stimulation amplitude of 0.28µA (14.8µC cm-2) at 60 Hz. The threshold ratio between focal and axonal activation increases from 1.1 for 100 Hz up to 1.6 for 60 Hz, while at 40 Hz stimulation frequency, almost no axonal responses were detected in the tested intensity range. With the use of synaptic blockers, we demonstrate the underlying direct activation mechanism of the ganglion cells. Finally, using high-resolution electrical imaging and label-free electrophysiological axon tracking, we demonstrate the extent of activation in axon bundles.Significance.Our results can be exploited to define a spatially selective stimulation strategy avoiding axonal activation in future retinal implants, thereby solving one of the major limitations of artificial vision. The results may be extended to other fields of neuroprosthetics to achieve selective focal electrical stimulation.
Collapse
Affiliation(s)
- Andrea Corna
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| | | | - Mai Thu Bui
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| | - Paul Werginz
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| | - Günther Zeck
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| |
Collapse
|
3
|
Seo HW, Cha S, Jeong Y, Ahn J, Lee KJ, Kim S, Goo YS. Focal stimulation of retinal ganglion cells using subretinal 3D microelectrodes with peripheral electrodes of opposite current. Biomed Eng Lett 2024; 14:355-365. [PMID: 38374901 PMCID: PMC10874361 DOI: 10.1007/s13534-023-00342-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 10/10/2023] [Accepted: 12/07/2023] [Indexed: 02/21/2024] Open
Abstract
Subretinal prostheses have been developed to stimulate survived retinal ganglion cells (RGCs), indirectly following the physiological visual pathways. However, current spreading from the prosthesis electrode causes the activation of unintended RGCs, thereby limiting the spatial resolution of artificial vision. This study proposes a strategy for focal stimulation of RGCs using a subretinal electrode array, in which six hexagonally arranged peripheral electrodes surround a stimulating electrode. RGCs in an in-vitro condition were subretinally stimulated using a fabricated electrode array coated with iridium oxide, following the three different stimulation configurations (with no peripheral, six electrodes of opposite current, and six ground). In-vitro experiments showed that the stimulation with six electrodes of opposite current was most effective in controlling RGC responses with a high spatial resolution. The results suggest that the effective utilization of return electrodes, such as by applying an opposite current to them, could help reduce current spreading beyond the local area targeted for stimulation and elicit RGC responses only in the vicinity of the stimulating electrode. Supplementary Information The online version contains supplementary material available at 10.1007/s13534-023-00342-3.
Collapse
Affiliation(s)
- Hee Won Seo
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Republic of Korea
| | - Seongkwang Cha
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, Republic of Korea
| | - Yurim Jeong
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, Republic of Korea
| | - Jungryul Ahn
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, Republic of Korea
| | - Kyeong Jae Lee
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Republic of Korea
| | - Sohee Kim
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Republic of Korea
| | - Yong Sook Goo
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, Republic of Korea
| |
Collapse
|
4
|
Richie J, Letner JG, Mclane-Svoboda A, Huan Y, Ghaffari DH, Valle ED, Patel PR, Chiel HJ, Pelled G, Weiland JD, Chestek CA. Fabrication and Validation of Sub-Cellular Carbon Fiber Electrodes. IEEE Trans Neural Syst Rehabil Eng 2024; 32:739-749. [PMID: 38294928 PMCID: PMC10919889 DOI: 10.1109/tnsre.2024.3360866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
Multielectrode arrays for interfacing with neurons are of great interest for a wide range of medical applications. However, current electrodes cause damage over time. Ultra small carbon fibers help to address issues but controlling the electrode site geometry is difficult. Here we propose a methodology to create small, pointed fiber electrodes (SPFe). We compare the SPFe to previously made blowtorched fibers in characterization. The SPFe result in small site sizes [Formula: see text] with consistently sharp points (20.8 ± 7.64°). Additionally, these electrodes were able to record and/or stimulate neurons multiple animal models including rat cortex, mouse retina, Aplysia ganglia and octopus axial cord. In rat cortex, these electrodes recorded significantly higher peak amplitudes than the traditional blowtorched fibers. These SPFe may be applicable to a wide range of applications requiring a highly specific interface with individual neurons.
Collapse
|
5
|
Vėbraitė I, Bar-Haim C, David-Pur M, Hanein Y. Bi-directional electrical recording and stimulation of the intact retina with a screen-printed soft probe: a feasibility study. Front Neurosci 2024; 17:1288069. [PMID: 38264499 PMCID: PMC10804455 DOI: 10.3389/fnins.2023.1288069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Accepted: 12/14/2023] [Indexed: 01/25/2024] Open
Abstract
Introduction Electrophysiological investigations of intact neural circuits are challenged by the gentle and complex nature of neural tissues. Bi-directional electrophysiological interfacing with the retina, in its intact form, is particularly demanding and currently there is no feasible approach to achieve such investigations. Here we present a feasibility study of a novel soft multi-electrode array suitable for bi-directional electrophysiological study of the intact retina. Methods Screen-printed soft electrode arrays were developed and tested. The soft probes were designed to accommodate the curvature of the retina in the eye and offer an opportunity to study the retina in its intact form. Results For the first time, we show both electrical recording and stimulation capabilities from the intact retina. In particular, we demonstrate the ability to characterize retina responses to electrical stimulation and reveal stable, direct, and indirect responses compared with ex-vivo conditions. Discussion These results demonstrate the unique performances of the new probe while also suggesting that intact retinas retain better stability and robustness than ex-vivo retinas making them more suitable for characterizing retina responses to electrical stimulation.
Collapse
Affiliation(s)
- Ieva Vėbraitė
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| | - Chen Bar-Haim
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| | - Moshe David-Pur
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| | - Yael Hanein
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
6
|
Ahn J, Yoo Y, Goo YS. Multiple consecutive-biphasic pulse stimulation improves spatially localized firing of retinal ganglion cells in the degenerate retina. THE KOREAN JOURNAL OF PHYSIOLOGY & PHARMACOLOGY : OFFICIAL JOURNAL OF THE KOREAN PHYSIOLOGICAL SOCIETY AND THE KOREAN SOCIETY OF PHARMACOLOGY 2023; 27:541-553. [PMID: 37884286 PMCID: PMC10613570 DOI: 10.4196/kjpp.2023.27.6.541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 08/08/2023] [Accepted: 08/22/2023] [Indexed: 10/28/2023]
Abstract
Retinal prostheses have shown some clinical success in restoring vision in patients with retinitis pigmentosa. However, the post-implantation visual acuity does not exceed that of legal blindness. The reason for the poor visual acuity might be that (1) degenerate retinal ganglion cells (RGCs) are less responsive to electrical stimulation than normal RGCs, and (2) electrically-evoked RGC spikes show a more widespread not focal response. The single-biphasic pulse electrical stimulation, commonly used in artificial vision, has limitations in addressing these issues. In this study, we propose the benefit of multiple consecutive-biphasic pulse stimulation. We used C57BL/6J mice and C3H/HeJ (rd1) mice for the normal retina and retinal degeneration model. An 8 × 8 multi-electrode array was used to record electrically-evoked RGC spikes. We compared RGC responses when increasing the amplitude of a single biphasic pulse versus increasing the number of consecutive biphasic pulses at the same stimulus charge. Increasing the amplitude of a single biphasic pulse induced more RGC spike firing while the spatial resolution of RGC populations decreased. For multiple consecutive-biphasic pulse stimulation, RGC firing increased as the number of pulses increased, and the spatial resolution of RGC populations was well preserved even up to 5 pulses. Multiple consecutive-biphasic pulse stimulation using two or three pulses in degenerate retinas induced as much RGC spike firing as in normal retinas. These findings suggest that the newly proposed multiple consecutive-biphasic pulse stimulation can improve the visual acuity in prosthesis-implanted patients.
Collapse
Affiliation(s)
- Jungryul Ahn
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju 28644, Korea
| | - Yongseok Yoo
- School of Computer Science and Engineering, Soongsil University, Seoul 06978, Korea
| | - Yong Sook Goo
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju 28644, Korea
| |
Collapse
|
7
|
Kerschensteiner D. Losing, preserving, and restoring vision from neurodegeneration in the eye. Curr Biol 2023; 33:R1019-R1036. [PMID: 37816323 PMCID: PMC10575673 DOI: 10.1016/j.cub.2023.08.044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/12/2023]
Abstract
The retina is a part of the brain that sits at the back of the eye, looking out onto the world. The first neurons of the retina are the rod and cone photoreceptors, which convert changes in photon flux into electrical signals that are the basis of vision. Rods and cones are frequent targets of heritable neurodegenerative diseases that cause visual impairment, including blindness, in millions of people worldwide. This review summarizes the diverse genetic causes of inherited retinal degenerations (IRDs) and their convergence onto common pathogenic mechanisms of vision loss. Currently, there are few effective treatments for IRDs, but recent advances in disparate areas of biology and technology (e.g., genome editing, viral engineering, 3D organoids, optogenetics, semiconductor arrays) discussed here enable promising efforts to preserve and restore vision in IRD patients with implications for neurodegeneration in less approachable brain areas.
Collapse
Affiliation(s)
- Daniel Kerschensteiner
- Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St. Louis, MO 63110, USA; Department of Neuroscience, Washington University School of Medicine, St. Louis, MO 63110, USA; Department of Biomedical Engineering, Washington University School of Medicine, St. Louis, MO 63110, USA.
| |
Collapse
|
8
|
Cha S, Ahn J, Kim SW, Choi KE, Yoo Y, Eom H, Shin D, Goo YS. The Variation of Electrical Pulse Duration Elicits Reliable Network-Mediated Responses of Retinal Ganglion Cells in Normal, Not in Degenerate Primate Retinas. Bioengineering (Basel) 2023; 10:1135. [PMID: 37892865 PMCID: PMC10604198 DOI: 10.3390/bioengineering10101135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 09/22/2023] [Accepted: 09/25/2023] [Indexed: 10/29/2023] Open
Abstract
This study aims to investigate the efficacy of electrical stimulation by comparing network-mediated RGC responses in normal and degenerate retinas using a N-methyl-N-nitrosourea (MNU)-induced non-human primate (NHPs) retinitis pigmentosa (RP) model. Adult cynomolgus monkeys were used for normal and outer retinal degeneration (RD) induced by MNU. The network-mediated RGC responses were recorded from the peripheral retina mounted on an 8 × 8 multielectrode array (MEA). The amplitude and duration of biphasic current pulses were modulated from 1 to 50 μA and 500 to 4000 μs, respectively. The threshold charge density for eliciting a network-mediated RGC response was higher in the RD monkeys than in the normal monkeys (1.47 ± 0.13 mC/cm2 vs. 1.06 ± 0.09 mC/cm2, p < 0.05) at a 500 μs pulse duration. The monkeys required a higher charge density than rodents among the RD models (monkeys; 1.47 ± 0.13 mC/cm2, mouse; 1.04 ± 0.09 mC/cm2, and rat; 1.16 ± 0.16 mC/cm2, p < 0.01). Increasing the pulse amplitude and pulse duration elicited more RGC spikes in the normal primate retinas. However, only pulse amplitude variation elicited more RGC spikes in degenerate primate retinas. Therefore, the pulse strategy for primate RD retinas should be optimized, eventually contributing to retinal prosthetics. Given that RD NHP RGCs are not sensitive to pulse duration, using shorter pulses may potentially be a more charge-effective approach for retinal prosthetics.
Collapse
Affiliation(s)
- Seongkwang Cha
- Department of Physiology, College of Medicine, Chungbuk National University, Cheongju 28644, Republic of Korea; (S.C.); (J.A.)
| | - Jungryul Ahn
- Department of Physiology, College of Medicine, Chungbuk National University, Cheongju 28644, Republic of Korea; (S.C.); (J.A.)
| | - Seong-Woo Kim
- Horang-I Eye Center, Seoul 07999, Republic of Korea;
| | - Kwang-Eon Choi
- Department of Ophthalmology, College of Medicine, Korea University, Seoul 08308, Republic of Korea;
| | - Yongseok Yoo
- School of Computer Science and Engineering, Soongsil University, Seoul 06978, Republic of Korea;
| | - Heejong Eom
- Laboratory Animal Center, Osong Medical Innovation Foundation, Cheongju 28160, Republic of Korea; (H.E.); (D.S.)
| | - Donggwan Shin
- Laboratory Animal Center, Osong Medical Innovation Foundation, Cheongju 28160, Republic of Korea; (H.E.); (D.S.)
| | - Yong Sook Goo
- Department of Physiology, College of Medicine, Chungbuk National University, Cheongju 28644, Republic of Korea; (S.C.); (J.A.)
| |
Collapse
|
9
|
Shpun G, Farah N, Chemla Y, Markus A, Leibovitch TA, Lasnoy E, Gerber D, Zalevsky Z, Mandel Y. Optimizing the fabrication of a 3D high-resolution implant for neural stimulation. J Biol Eng 2023; 17:55. [PMID: 37620951 PMCID: PMC10463680 DOI: 10.1186/s13036-023-00370-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Accepted: 07/24/2023] [Indexed: 08/26/2023] Open
Abstract
BACKGROUND Tissue-integrated micro-electronic devices for neural stimulation hold great potential in restoring the functionality of degenerated organs, specifically, retinal prostheses, which are aimed at vision restoration. The fabrication process of 3D polymer-metal devices with high resolution and a high aspect-ratio (AR) is very complex and faces many challenges that impair its functionality. APPROACH Here we describe the optimization of the fabrication process of a bio-functionalized 3D high-resolution 1mm circular subretinal implant composed of SU-8 polymer integrated with dense gold microelectrodes (23μm pitch) passivated with 3D micro-well-like structures (20μm diameter, 3μm resolution). The main challenges were overcome by step-by-step planning and optimization while utilizing a two-step bi-layer lift-off process; bio-functionalization was carried out by N2 plasma treatment and the addition of a bio-adhesion molecule. MAIN RESULTS In-vitro and in-vivo investigations, including SEM and FIB cross section examinations, revealed a good structural design, as well as a good long-term integration of the device in the rat sub-retinal space and cell migration into the wells. Moreover, the feasibility of subretinal neural stimulation using the fabricated device was demonstrated in-vitro by electrical activation of rat's retina. CONCLUSIONS The reported process and optimization steps described here in detail can aid in designing and fabricating retinal prosthetic devices or similar neural implants.
Collapse
Affiliation(s)
- Gal Shpun
- The Alexander Kofkin Faculty of Engineering, Bar Ilan University, 5290002, Ramat Gan, Israel
- Faculty of Life Sciences, School of Optometry & Visual Science, Bar Ilan University, 5290002, Ramat Gan, Israel
- Bar Ilan Institute for Nanotechnology & Advanced Materials (BINA), Bar Ilan University, 5290002, Ramat Gan, Israel
| | - Nairouz Farah
- Faculty of Life Sciences, School of Optometry & Visual Science, Bar Ilan University, 5290002, Ramat Gan, Israel
- Bar Ilan Institute for Nanotechnology & Advanced Materials (BINA), Bar Ilan University, 5290002, Ramat Gan, Israel
| | - Yoav Chemla
- Faculty of Life Sciences, School of Optometry & Visual Science, Bar Ilan University, 5290002, Ramat Gan, Israel
- Bar Ilan Institute for Nanotechnology & Advanced Materials (BINA), Bar Ilan University, 5290002, Ramat Gan, Israel
| | - Amos Markus
- Faculty of Life Sciences, School of Optometry & Visual Science, Bar Ilan University, 5290002, Ramat Gan, Israel
- Bar Ilan Institute for Nanotechnology & Advanced Materials (BINA), Bar Ilan University, 5290002, Ramat Gan, Israel
| | - Tamar Azrad Leibovitch
- Faculty of Life Sciences, School of Optometry & Visual Science, Bar Ilan University, 5290002, Ramat Gan, Israel
- Bar Ilan Institute for Nanotechnology & Advanced Materials (BINA), Bar Ilan University, 5290002, Ramat Gan, Israel
| | - Erel Lasnoy
- Faculty of Life Sciences, School of Optometry & Visual Science, Bar Ilan University, 5290002, Ramat Gan, Israel
- Bar Ilan Institute for Nanotechnology & Advanced Materials (BINA), Bar Ilan University, 5290002, Ramat Gan, Israel
| | - Doron Gerber
- Bar Ilan Institute for Nanotechnology & Advanced Materials (BINA), Bar Ilan University, 5290002, Ramat Gan, Israel
| | - Zeev Zalevsky
- The Alexander Kofkin Faculty of Engineering, Bar Ilan University, 5290002, Ramat Gan, Israel
- Bar Ilan Institute for Nanotechnology & Advanced Materials (BINA), Bar Ilan University, 5290002, Ramat Gan, Israel
| | - Yossi Mandel
- Faculty of Life Sciences, School of Optometry & Visual Science, Bar Ilan University, 5290002, Ramat Gan, Israel.
- Bar Ilan Institute for Nanotechnology & Advanced Materials (BINA), Bar Ilan University, 5290002, Ramat Gan, Israel.
- The Gonda Multidisciplinary Brain Research Center, Bar-Ilan University, Ramat Gan, Israel.
| |
Collapse
|
10
|
Palanker D. Electronic Retinal Prostheses. Cold Spring Harb Perspect Med 2023; 13:a041525. [PMID: 36781222 PMCID: PMC10411866 DOI: 10.1101/cshperspect.a041525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2023]
Abstract
Retinal prostheses are a promising means for restoring sight to patients blinded by photoreceptor atrophy. They introduce visual information by electrical stimulation of the surviving inner retinal neurons. Subretinal implants target the graded-response secondary neurons, primarily the bipolar cells, which then transfer the information to the ganglion cells via the retinal neural network. Therefore, many features of natural retinal signal processing can be preserved in this approach if the inner retinal network is retained. Epiretinal implants stimulate primarily the ganglion cells, and hence should encode the visual information in spiking patterns, which, ideally, should match the target cell types. Currently, subretinal arrays are being developed primarily for restoration of central vision in patients impaired by age-related macular degeneration (AMD), while epiretinal implants-for patients blinded by retinitis pigmentosa, where the inner retina is less preserved. This review describes the concepts and technologies, preclinical characterization of prosthetic vision and clinical outcomes, and provides a glimpse into future developments.
Collapse
Affiliation(s)
- Daniel Palanker
- Department of Ophthalmology and Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305, USA
| |
Collapse
|
11
|
Ahn J, Jeong Y, Cha S, Lee JY, Yoo Y, Goo YS. High amplitude pulses on the same charge condition efficiently elicit bipolar cell-mediated retinal ganglion cell responses in the degenerate retina. Biomed Eng Lett 2023; 13:129-140. [PMID: 37124107 PMCID: PMC10130300 DOI: 10.1007/s13534-023-00260-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 12/19/2022] [Accepted: 01/09/2023] [Indexed: 02/01/2023] Open
Abstract
Retinal pigmentosa (RP) patients lose vision due to the loss of photoreceptors. Retinal prostheses bypass the dead photoreceptors by electrically stimulating surviving retinal neurons, such as bipolar cells or retinal ganglion cells (RGCs). In previous studies, stimulus charge has been mainly optimized to maximize the RGC response to electrical stimulation. This study aimed to investigate the effect of amplitude and duration even under the same charge condition on eliciting RGC spikes in the wild-type and degenerate retinas. Wild-type (WT) Sprague-Dawley rats were used as the normal retinal model, and Pde6b knockout rats were used as a retinal degeneration (RD) model. Electrically-evoked RGC spikes were recorded from isolated rat retinas using an 8 × 8 multielectrode array. The same charge was maintained (10 or 20 nC), and electrical stimulation was applied to WT and RD retinas, adjusting the amplitude and duration of the 1st phase of biphasic pulses. In the pulse modulation of the 1st phase, high amplitude (short duration) pulses induced more RGC spikes than low amplitude (long duration) pulses. Both WT and RD retinas showed a significant reduction in the number of RGC spikes upon stimulation with lower amplitude (longer duration) pulses. In clinical trials where stimulus charges are delivered to the degenerate retina of blind patients, high amplitude (short duration) pulses would help elicit more RGC spikes.
Collapse
Affiliation(s)
- Jungryul Ahn
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, South Korea
| | - Yurim Jeong
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, South Korea
| | - Seongkwang Cha
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, South Korea
| | - Joo Yong Lee
- Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| | - Yongseok Yoo
- School of Computer Science and Engineering, Soongsil University, Seoul, South Korea
| | - Yong Sook Goo
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, South Korea
| |
Collapse
|
12
|
Begeng JM, Tong W, Rosal BD, Ibbotson M, Kameneva T, Stoddart PR. Activity of Retinal Neurons Can Be Modulated by Tunable Near-Infrared Nanoparticle Sensors. ACS NANO 2023; 17:2079-2088. [PMID: 36724043 DOI: 10.1021/acsnano.2c07663] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The vision of patients rendered blind by photoreceptor degeneration can be partially restored by exogenous stimulation of surviving retinal ganglion cells (RGCs). Whereas conventional electrical stimulation techniques have failed to produce naturalistic visual percepts, nanoparticle-based optical sensors have recently received increasing attention as a means to artificially stimulate the RGCs. In particular, nanoparticle-enhanced infrared neural modulation (NINM) is a plasmonically mediated photothermal neuromodulation technique that has a demonstrated capacity for both stimulation and inhibition, which is essential for the differential modulation of ON-type and OFF-type RGCs. Gold nanorods provide tunable absorption through the near-infrared wavelength window, which reduces interference with any residual vision. Therefore, NINM may be uniquely well-suited to retinal prosthesis applications but, to our knowledge, has not previously been demonstrated in RGCs. In the present study, NINM laser pulses of 100 μs, 500 μs and 200 ms were applied to RGCs in explanted rat retinae, with single-cell responses recorded via patch-clamping. The shorter laser pulses evoked robust RGC stimulation by capacitive current generation, while the long laser pulses are capable of inhibiting spontaneous action potentials by thermal block. Importantly, an implicit bias toward OFF-type inhibition is observed, which may have important implications for the feasibility of future high-acuity retinal prosthesis design based on nanoparticle sensors.
Collapse
Affiliation(s)
- James M Begeng
- School of Science, Computing and Engineering Technologies, Swinburne University of Technology, John Street, Hawthorn, VictoriaAustralia3122
- The Australian College of Optometry, The National Vision Research Institute, 386 Cardigan Street, Carlton, VictoriaAustralia3053
| | - Wei Tong
- The Australian College of Optometry, The National Vision Research Institute, 386 Cardigan Street, Carlton, VictoriaAustralia3053
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Melbourne, Victoria, Australia3010
- School of Physics, The University of Melbourne, Parkville, Melbourne, Victoria, Australia3010
| | - Blanca Del Rosal
- School of Science, RMIT University, Melbourne, Victoria, Australia3000
| | - Michael Ibbotson
- The Australian College of Optometry, The National Vision Research Institute, 386 Cardigan Street, Carlton, VictoriaAustralia3053
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Melbourne, Victoria, Australia3010
| | - Tatiana Kameneva
- School of Science, Computing and Engineering Technologies, Swinburne University of Technology, John Street, Hawthorn, VictoriaAustralia3122
| | - Paul R Stoddart
- School of Science, Computing and Engineering Technologies, Swinburne University of Technology, John Street, Hawthorn, VictoriaAustralia3122
| |
Collapse
|
13
|
Carleton M, Oesch NW. Differences in the spatial fidelity of evoked and spontaneous signals in the degenerating retina. Front Cell Neurosci 2022; 16:1040090. [PMID: 36419935 PMCID: PMC9676928 DOI: 10.3389/fncel.2022.1040090] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Accepted: 10/20/2022] [Indexed: 07/01/2024] Open
Abstract
Vision restoration strategies aim to reestablish vision by replacing the function of lost photoreceptors with optoelectronic hardware or through gene therapy. One complication to these approaches is that retinal circuitry undergoes remodeling after photoreceptor loss. Circuit remodeling following perturbation is ubiquitous in the nervous system and understanding these changes is crucial for treating neurodegeneration. Spontaneous oscillations that arise during retinal degeneration have been well-studied, however, other changes in the spatiotemporal processing of evoked and spontaneous activity have received less attention. Here we use subretinal electrical stimulation to measure the spatial and temporal spread of both spontaneous and evoked activity during retinal degeneration. We found that electrical stimulation synchronizes spontaneous oscillatory activity, over space and through time, thus leading to increased correlations in ganglion cell activity. Intriguingly, we found that spatial selectivity was maintained in rd10 retina for evoked responses, with spatial receptive fields comparable to wt retina. These findings indicate that different biophysical mechanisms are involved in mediating feed forward excitation, and the lateral spread of spontaneous activity in the rd10 retina, lending support toward the possibility of high-resolution vision restoration.
Collapse
Affiliation(s)
- Maya Carleton
- Department of Psychology, University of California, San Diego, La Jolla, CA, United States
| | - Nicholas W. Oesch
- Department of Psychology, University of California, San Diego, La Jolla, CA, United States
- Department of Ophthalmology, University of California, San Diego, La Jolla, CA, United States
- The Neurosciences Graduate Program, University of California, San Diego, La Jolla, CA, United States
| |
Collapse
|
14
|
Caravaca-Rodriguez D, Gaytan SP, Suaning GJ, Barriga-Rivera A. Implications of Neural Plasticity in Retinal Prosthesis. Invest Ophthalmol Vis Sci 2022; 63:11. [PMID: 36251317 DOI: 10.1167/iovs.63.11.11] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Retinal degenerative diseases such as retinitis pigmentosa cause a progressive loss of photoreceptors that eventually prevents the affected person from perceiving visual sensations. The absence of a visual input produces a neural rewiring cascade that propagates along the visual system. This remodeling occurs first within the retina. Then, subsequent neuroplastic changes take place at higher visual centers in the brain, produced by either the abnormal neural encoding of the visual inputs delivered by the diseased retina or as the result of an adaptation to visual deprivation. While retinal implants can activate the surviving retinal neurons by delivering electric current, the unselective activation patterns of the different neural populations that exist in the retinal layers differ substantially from those in physiologic vision. Therefore, artificially induced neural patterns are being delivered to a brain that has already undergone important neural reconnections. Whether or not the modulation of this neural rewiring can improve the performance for retinal prostheses remains a critical question whose answer may be the enabler of improved functional artificial vision and more personalized neurorehabilitation strategies.
Collapse
Affiliation(s)
- Daniel Caravaca-Rodriguez
- Department of Applied Physics III, Technical School of Engineering, Universidad de Sevilla, Sevilla, Spain
| | - Susana P Gaytan
- Department of Physiology, Universidad de Sevilla, Sevilla, Spain
| | - Gregg J Suaning
- School of Biomedical Engineering, University of Sydney, Sydney, Australia
| | - Alejandro Barriga-Rivera
- Department of Applied Physics III, Technical School of Engineering, Universidad de Sevilla, Sevilla, Spain.,School of Biomedical Engineering, University of Sydney, Sydney, Australia
| |
Collapse
|
15
|
Wang BY, Chen ZC, Bhuckory M, Kochnev Goldstein A, Palanker D. Pixel size limit of the PRIMA implants: from humans to rodents and back. J Neural Eng 2022; 19:10.1088/1741-2552/ac8e31. [PMID: 36044878 PMCID: PMC9527086 DOI: 10.1088/1741-2552/ac8e31] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 08/31/2022] [Indexed: 11/11/2022]
Abstract
Objective.Retinal prostheses aim at restoring sight in patients with retinal degeneration by electrically stimulating the inner retinal neurons. Clinical trials with patients blinded by atrophic age-related macular degeneration using the PRIMA subretinal implant, a 2 × 2 mm array of 100µm-wide photovoltaic pixels, have demonstrated a prosthetic visual acuity closely matching the pixel size. Further improvement in resolution requires smaller pixels, which, with the current bipolar design, necessitates more intense stimulation.Approach.We examine the lower limit of the pixel size for PRIMA implants by modeling the electric field, leveraging the clinical benchmarks, and using animal data to assess the stimulation strength and contrast of various patterns. Visually evoked potentials measured in Royal College of Surgeons rats with photovoltaic implants composed of 100µm and 75µm pixels were compared to clinical thresholds with 100µm pixels. Electrical stimulation model calibrated by the clinical and rodent data was used to predict the performance of the implant with smaller pixels.Main results.PRIMA implants with 75µm bipolar pixels under the maximum safe near-infrared (880 nm) illumination of 8 mW mm-2with 30% duty cycle (10 ms pulses at 30 Hz) should provide a similar perceptual brightness as with 100µm pixels under 3 mW mm-2irradiance, used in the current clinical trials. Contrast of the Landolt C pattern scaled down to 75µm pixels is also similar under such illumination to that with 100µm pixels, increasing the maximum acuity from 20/420 to 20/315.Significance.Computational modeling defines the minimum pixel size of the PRIMA implants as 75µm. Increasing the implant width from 2 to 3 mm and reducing the pixel size from 100 to 75µm will nearly quadrupole the number of pixels, which should be very beneficial for patients. Smaller pixels of the same bipolar flat geometry would require excessively intense illumination, and therefore a different pixel design should be considered for further improvement in resolution.
Collapse
Affiliation(s)
- Bing-Yi Wang
- Department of Physics, Stanford University, Stanford, CA, United States of America
| | - Zhijie Charles Chen
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America
| | - Mohajeet Bhuckory
- Department of Ophthalmology, Stanford University, Stanford, CA, United States of America
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | - Anna Kochnev Goldstein
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America
| | - Daniel Palanker
- Department of Ophthalmology, Stanford University, Stanford, CA, United States of America
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| |
Collapse
|
16
|
Haq W, Basavaraju S, Speck A, Zrenner E. Nature-inspired saccadic-like electrical stimulation paradigm promotes sustained retinal ganglion cell responses by spatiotemporally alternating activation of contiguous multi-electrode patterns. J Neural Eng 2022; 19. [PMID: 36066085 DOI: 10.1088/1741-2552/ac8ad0] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 08/18/2022] [Indexed: 11/12/2022]
Abstract
Objective. Retinal electrical stimulation using multi-electrode arrays (MEAs) aims to restore visual object perception in blind patients. However, the rate and duration of the artificial visual sensations are limited due to the rapid response decay of the stimulated neurons. Hence, we investigated a novel nature-inspired saccadic-like stimulation paradigm (biomimetic) to evoke sustained retinal responses. For implementation, the macroelectrode was replaced by several contiguous microelectrodes and activated non-simultaneously but alternating topologically.Approach.MEAs with hexagonally arranged electrodes were utilized to simulate and record mouse retinal ganglion cells (RGCs). Two shapes were presented electrically using MEAs: a 6e-hexagon (six hexagonally arranged 10µm electrodes; 6e-hexagon diameter: 80µm) and a double-bar (180µm spaced, 320µm in length). Electrodes of each shape were activated in three different modes (simultaneous, circular, and biomimetic ('zig-zag')), stimulating at different frequencies (1-20 Hz).Main results.The biomimetic stimulation generated enhanced RGC responses increasing the activity rate by 87.78%. In the spatiotemporal context, the electrical representation of the 6e-hexagon produced sustained and local RGC responses (∼130µm corresponding to ∼2.5° of the human visual angle) for up to 90 s at 10 Hz stimulation and resolved the electrically presented double-bar. In contrast, during conventional simultaneous stimulation, the responses were poor and declined within seconds. Similarly, the applicability of the biomimetic mode for retinal implants (7 × 8 pixels) was successfully demonstrated. An object shape impersonating a smile was presented electrically, and the recorded data were used to emulate the implant's performance. The spatiotemporal pixel mapping of the activity produced a complete retinal image of the smile.Significance.The application of electrical stimulation in the biomimetic mode produced locally enhanced RGC responses with significantly reduced fading effects and yielded advanced spatiotemporal performance reflecting the presented electrode shapes in the mapped activity imprint. Therefore, it is likely that the RGC responses persist long enough to evoke visual perception and generate a seamless image, taking advantage of the flicker fusion. Hence, replacing the implant's macroelectrodes with microelectrodes and their activation in a topologically alternating biomimetic fashion may overcome the patient's perceptual image fading, thereby enhancing the spatiotemporal characteristics of artificial vision.
Collapse
Affiliation(s)
- Wadood Haq
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| | - Sunetra Basavaraju
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| | - Achim Speck
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| | - Eberhart Zrenner
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| |
Collapse
|
17
|
Roh H, Otgondemberel Y, Im M. Short pulses of epiretinal prostheses evoke network-mediated responses in retinal ganglion cells by stimulating presynaptic neurons. J Neural Eng 2022; 19. [PMID: 36055185 DOI: 10.1088/1741-2552/ac8ed7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 09/02/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Microelectronic retinal implant aims to restore functional vision with electric stimulation. Short pulses are generally known to directly activate retinal ganglion cells (RGCs) with a notion of one or two spike(s) per pulse. In the present work, we systematically explore network-mediated responses that arise from various short pulses in both normal and degenerate retinas. APPROACH Cell-attached patch clamping was used to record spiking responses of RGCs in wild-type (C57BL/6J) and retinal degeneration (rd10) mice. Alpha RGCs of the mouse retinas were targeted by their large soma sizes and classified by their responses to spot flashes. Then, RGCs were electrically stimulated by various conditions such as duration (100-460 μs), count (1-10), amplitude (100-400 μA), and repeating frequency (10-40 Hz) of short pulses. Also, their responses were compared with each own response to a single 4-ms-long pulse which is known to evoke strong indirect responses. MAIN RESULTS Short pulses evoked strong network-mediated responses not only in both ON and OFF types of RGCs in the healthy retinas but also in RGCs of the severely degenerate retina. However, the spike timing consistency across repeats not decreased significantly in the rd10 RGCs compared to the healthy ON and OFF RGCs. Network-mediated responses of ON RGCs were highly dependent on the current amplitude of stimuli but much less on the pulse count and the repetition frequency. In contrast, responses of OFF RGCs were more influenced by the number of stimuli than the current amplitude. SIGNIFICANCE Our results demonstrate that short pulses also elicit indirect responses by activating presynaptic neurons. In the case of the commercial retinal prostheses using repeating short pulses, there is a possibility that the performance of clinical devices is highly related to the preserved retinal circuits. Therefore, examination of surviving retinal neurons in patients would be necessary to improve the efficacy of retinal prostheses.
Collapse
Affiliation(s)
- Hyeonhee Roh
- Korea Institute of Science and Technology (KIST), 5 Hwarang-ro 14-gil, Seongbuk-gu, Seoul, 02792, Korea (the Republic of)
| | - Yanjinsuren Otgondemberel
- Brain Science Institute, Korea Institute of Science and Technology (KIST), 5 Hwarang-ro 14-gil, Seongbuk-gu, Seoul, 02792, Korea (the Republic of)
| | - Maesoon Im
- Brain Science Institute, Center for BioMicrosystems, Korea Institute of Science and Technology, 5 Hwarang-ro 14-gil, Seongbuk-gu, L7325B, Seoul, Seoul, Seoul, 02792, Korea (the Republic of)
| |
Collapse
|
18
|
Li W, Haji Ghaffari D, Misra R, Weiland JD. Retinal ganglion cell desensitization is mitigated by varying parameter constant excitation pulse trains. Front Cell Neurosci 2022; 16:897146. [PMID: 36035262 PMCID: PMC9407683 DOI: 10.3389/fncel.2022.897146] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Accepted: 07/15/2022] [Indexed: 11/20/2022] Open
Abstract
Retinal prostheses partially restore vision in patients blinded by retinitis pigmentosa (RP) and age-related macular degeneration (AMD). One issue that limits the effectiveness of retinal stimulation is the desensitization of the retina response to repeated pulses. Rapid fading of percepts is reported in clinical studies. We studied the retinal output evoked by fixed pulse trains vs. pulse trains that have variable parameters pulse-to-pulse. We used the current clamp to record RGC spiking in the isolated mouse retina. Trains of biphasic current pulses at different frequencies and amplitudes were applied. The main results we report are: (1) RGC desensitization was induced by increasing stimulus frequency, but was unrelated to stimulus amplitude. Desensitization persisted when the 20 Hz stimulation pulses were applied to the retinal ganglion cells at 65 μA, 85 μA, and 105 μA. Subsequent pulses in the train evoked fewer spikes. There was no obvious desensitization when 2 Hz stimulation pulse trains were applied. (2) Blocking inhibitory GABAA receptor increased spontaneous activity but did not reduce desensitization. (3) Pulse trains with constant charge or excitation (based on strength-duration curves) but varying pulse width, amplitude, and shape increased the number of evoked spikes/pulse throughout the pulse train. This suggests that retinal desensitization can be partially overcome by introducing variability into each pulse.
Collapse
Affiliation(s)
- Wennan Li
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States
| | - Dorsa Haji Ghaffari
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States
| | - Rohit Misra
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States
| | - James D. Weiland
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States
- Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, MI, United States
- Biointerfaces Institute, University of Michigan, Ann Arbor, MI, United States
- *Correspondence: James D. Weiland
| |
Collapse
|
19
|
Cha S, Ahn J, Jeong Y, Lee YH, Kim HK, Lee D, Yoo Y, Goo YS. Stage-Dependent Changes of Visual Function and Electrical Response of the Retina in the rd10 Mouse Model. Front Cell Neurosci 2022; 16:926096. [PMID: 35936494 PMCID: PMC9345760 DOI: 10.3389/fncel.2022.926096] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Accepted: 06/23/2022] [Indexed: 12/28/2022] Open
Abstract
One of the critical prerequisites for the successful development of retinal prostheses is understanding the physiological features of retinal ganglion cells (RGCs) in the different stages of retinal degeneration (RD). This study used our custom-made rd10 mice, C57BL/6-Pde6bem1(R560C)Dkl/Korl mutated on the Pde6b gene in C57BL/6J mouse with the CRISPR/Cas9-based gene-editing method. We selected the postnatal day (P) 45, P70, P140, and P238 as representative ages for RD stages. The optomotor response measured the visual acuity across degeneration stages. At P45, the rd10 mice exhibited lower visual acuity than wild-type (WT) mice. At P140 and older, no optomotor response was observed. We classified RGC responses to the flashed light into ON, OFF, and ON/OFF RGCs via in vitro multichannel recording. With degeneration, the number of RGCs responding to the light stimulation decreased in all three types of RGCs. The OFF response disappeared faster than the ON response with older postnatal ages. We elicited RGC spikes with electrical stimulation and analyzed the network-mediated RGC response in the rd10 mice. Across all postnatal ages, the spikes of rd10 RGCs were less elicited by pulse amplitude modulation than in WT RGCs. The ratio of RGCs showing multiple peaks of spike burst increased in older ages. The electrically evoked RGC spikes by the pulse amplitude modulation differ across postnatal ages. Therefore, degeneration stage-dependent stimulation strategies should be considered for developing retinal prosthesis and successful vision restoration.
Collapse
Affiliation(s)
- Seongkwang Cha
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, South Korea
| | - Jungryul Ahn
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, South Korea
| | - Yurim Jeong
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, South Korea
| | - Yong Hee Lee
- Department of Biochemistry, Chungbuk National University School of Medicine, Cheongju, South Korea
| | - Hyong Kyu Kim
- Department of Microbiology, Chungbuk National University School of Medicine, Cheongju, South Korea
| | - Daekee Lee
- Department of Life Science, Ewha Womans University, Seoul, South Korea
| | - Yongseok Yoo
- Department of Electronics Engineering, Incheon National University, Incheon, South Korea
- *Correspondence: Yongseok Yoo,
| | - Yong Sook Goo
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, South Korea
- Yong Sook Goo,
| |
Collapse
|
20
|
Ahn J, Cha S, Choi KE, Kim SW, Yoo Y, Goo YS. Correlated Activity in the Degenerate Retina Inhibits Focal Response to Electrical Stimulation. Front Cell Neurosci 2022; 16:889663. [PMID: 35602554 PMCID: PMC9114441 DOI: 10.3389/fncel.2022.889663] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Accepted: 04/13/2022] [Indexed: 11/24/2022] Open
Abstract
Retinal prostheses have shown some clinical success in patients with retinitis pigmentosa and age-related macular degeneration. However, even after the implantation of a retinal prosthesis, the patient’s visual acuity is at best less than 20/420. Reduced visual acuity may be explained by a decrease in the signal-to-noise ratio due to the spontaneous hyperactivity of retinal ganglion cells (RGCs) found in degenerate retinas. Unfortunately, abnormal retinal rewiring, commonly observed in degenerate retinas, has rarely been considered for the development of retinal prostheses. The purpose of this study was to investigate the aberrant retinal network response to electrical stimulation in terms of the spatial distribution of the electrically evoked RGC population. An 8 × 8 multielectrode array was used to measure the spiking activity of the RGC population. RGC spikes were recorded in wild-type [C57BL/6J; P56 (postnatal day 56)], rd1 (P56), rd10 (P14 and P56) mice, and macaque [wild-type and drug-induced retinal degeneration (RD) model] retinas. First, we performed a spike correlation analysis between RGCs to determine RGC connectivity. No correlation was observed between RGCs in the control group, including wild-type mice, rd10 P14 mice, and wild-type macaque retinas. In contrast, for the RD group, including rd1, rd10 P56, and RD macaque retinas, RGCs, up to approximately 400–600 μm apart, were significantly correlated. Moreover, to investigate the RGC population response to electrical stimulation, the number of electrically evoked RGC spikes was measured as a function of the distance between the stimulation and recording electrodes. With an increase in the interelectrode distance, the number of electrically evoked RGC spikes decreased exponentially in the control group. In contrast, electrically evoked RGC spikes were observed throughout the retina in the RD group, regardless of the inter-electrode distance. Taken together, in the degenerate retina, a more strongly coupled retinal network resulted in the widespread distribution of electrically evoked RGC spikes. This finding could explain the low-resolution vision in prosthesis-implanted patients.
Collapse
Affiliation(s)
- Jungryul Ahn
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, South Korea
| | - Seongkwang Cha
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, South Korea
| | - Kwang-Eon Choi
- Department of Ophthalmology, Korea University College of Medicine, Seoul, South Korea
| | - Seong-Woo Kim
- Department of Ophthalmology, Korea University College of Medicine, Seoul, South Korea
- *Correspondence: Seong-Woo Kim,
| | - Yongseok Yoo
- Department of Electronics Engineering, Incheon National University, Incheon, South Korea
- Yongseok Yoo,
| | - Yong Sook Goo
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, South Korea
- Yong Sook Goo,
| |
Collapse
|
21
|
Raghuram V, Werginz P, Fried SI, Timko BP. Morphological Factors that Underlie Neural Sensitivity to Stimulation in the Retina. ADVANCED NANOBIOMED RESEARCH 2022; 1. [PMID: 35399546 DOI: 10.1002/anbr.202100069] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Retinal prostheses are a promising therapeutic intervention for patients afflicted by outer retinal degenerative diseases like retinitis pigmentosa and age-related macular degeneration. While significant advances in the development of retinal implants have been made, the quality of vision elicited by these devices remains largely sub-optimal. The variability in the responses produced by retinal devices is most likely due to the differences between the natural cell type-specific signaling that occur in the healthy retina vs. the non-specific activation of multiple cell types arising from artificial stimulation. In order to replicate these natural signaling patterns, stimulation strategies must be capable of preferentially activating specific RGC types. To design more selective stimulation strategies, a better understanding of the morphological factors that underlie the sensitivity to prosthetic stimulation must be developed. This review will focus on the role that different anatomical components play in driving the direct activation of RGCs by extracellular stimulation. Briefly, it will (1) characterize the variability in morphological properties of α-RGCs, (2) detail the influence of morphology on the direct activation of RGCs by electric stimulation, and (3) describe some of the potential biophysical mechanisms that could explain differences in activation thresholds and electrically evoked responses between RGC types.
Collapse
Affiliation(s)
- Vineeth Raghuram
- Boston VA Healthcare System, 150 S Huntington Ave, Boston, MA 02130, USA.,Dept. of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, MA 02155, USA.,Dept. of Neurosurgery, Massachusetts General Hospital - Harvard Medical School, 50 Blossom Street, Boston, MA, 02114
| | - Paul Werginz
- Institute for Analysis and Scientific Computing, Vienna University of Technology, Wiedner Hauptstrasse 8-10, Vienna, Austria.,Dept. of Neurosurgery, Massachusetts General Hospital - Harvard Medical School, 50 Blossom Street, Boston, MA, 02114
| | - Shelley I Fried
- Boston VA Healthcare System, 150 S Huntington Ave, Boston, MA 02130, USA.,Dept. of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, MA 02155, USA.,Dept. of Neurosurgery, Massachusetts General Hospital - Harvard Medical School, 50 Blossom Street, Boston, MA, 02114
| | - Brian P Timko
- Dept. of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, MA 02155, USA
| |
Collapse
|
22
|
Cha S, Choi KE, Ahn J, Yoo M, Jeong Y, Kim SW, Goo YS. Electrical response of retinal ganglion cells in an N-methyl-N-nitrosourea-induced retinal degeneration porcine model. Sci Rep 2021; 11:24135. [PMID: 34921172 PMCID: PMC8683404 DOI: 10.1038/s41598-021-03439-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 12/02/2021] [Indexed: 12/28/2022] Open
Abstract
Retinal prosthesis is regarded as the treatment for vision restoration in the blind with retinal degeneration (RD) due to the loss of photoreceptors. A strategy for retinal prosthesis is to electrically activate surviving neurons. The retina’s response to electrical stimulation in a larger RD model has not been studied yet. Therefore, in this study, we investigated electrically evoked retinal responses in a previously validated N-methyl-N-nitrosourea (MNU)-induced porcine RD model. Electrically evoked responses were evaluated based on the number of retinal ganglion cell (RGC) spikes via multichannel recordings. Stimulation pulses were applied to degenerative and wild-type retinas with pulse modulation. Compared to wild-type retinas, degenerative retinas showed higher threshold values of pulse amplitude and pulse duration. The rate of increase in the number of RGC spikes relative to stimulus intensity was lower in degenerative retinas than in normal retinas. In severely degenerated retinas, few RGCs showed electrically evoked spikes. Our results suggest that the degenerative porcine retina requires a higher charge than the normal porcine retina. In the early stage of RD, it is easier to induce RGC spikes through electrical stimulation using retinal prosthesis; however, when the degeneration is severe, there may be difficulty recovering patient vision.
Collapse
Affiliation(s)
- Seongkwang Cha
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, 28644, Korea
| | - Kwang-Eon Choi
- Department of Ophthalmology, Korea University College of Medicine, Seoul, 08308, Korea
| | - Jungryul Ahn
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, 28644, Korea
| | - Minsu Yoo
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, 28644, Korea
| | - Yurim Jeong
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, 28644, Korea
| | - Seong-Woo Kim
- Department of Ophthalmology, Korea University College of Medicine, Seoul, 08308, Korea.
| | - Yong Sook Goo
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju, 28644, Korea.
| |
Collapse
|
23
|
Paknahad J, Kosta P, Bouteiller JMC, Humayun MS, Lazzi G. Mechanisms underlying activation of retinal bipolar cells through targeted electrical stimulation: a computational study. J Neural Eng 2021; 18. [PMID: 34826830 DOI: 10.1088/1741-2552/ac3dd8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Accepted: 11/26/2021] [Indexed: 11/12/2022]
Abstract
Objective. Retinal implants have been developed to electrically stimulate healthy retinal neurons in the progressively degenerated retina. Several stimulation approaches have been proposed to improve the visual percept induced in patients with retinal prostheses. We introduce a computational model capable of simulating the effects of electrical stimulation on retinal neurons. Leveraging this computational platform, we delve into the underlying mechanisms influencing the sensitivity of retinal neurons' response to various stimulus waveforms.Approach. We implemented a model of spiking bipolar cells (BCs) in the magnocellular pathway of the primate retina, diffuse BC subtypes (DB4), and utilized our multiscale admittance method (AM)-NEURON computational platform to characterize the response of BCs to epiretinal electrical stimulation with monophasic, symmetric, and asymmetric biphasic pulses.Main results. Our investigations yielded four notable results: (a) the latency of BCs increases as stimulation pulse duration lengthens; conversely, this latency decreases as the current amplitude increases. (b) Stimulation with a long anodic-first symmetric biphasic pulse (duration > 8 ms) results in a significant decrease in spiking threshold compared to stimulation with similar cathodic-first pulses (from 98.2 to 57.5µA). (c) The hyperpolarization-activated cyclic nucleotide-gated channel was a prominent contributor to the reduced threshold of BCs in response to long anodic-first stimulus pulses. (d) Finally, extending the study to asymmetric waveforms, our results predict a lower BCs threshold using asymmetric long anodic-first pulses compared to that of asymmetric short cathodic-first stimulation.Significance. This study predicts the effects of several stimulation parameters on spiking BCs response to electrical stimulation. Of importance, our findings shed light on mechanisms underlying the experimental observations from the literature, thus highlighting the capability of the methodology to predict and guide the development of electrical stimulation protocols to generate a desired biological response, thereby constituting an ideal testbed for the development of electroceutical devices.
Collapse
Affiliation(s)
- Javad Paknahad
- Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA, United States of America.,Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA, United States of America
| | - Pragya Kosta
- Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA, United States of America
| | - Jean-Marie C Bouteiller
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America
| | - Mark S Humayun
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America.,Department of Ophthalmology, University of Southern California, Los Angeles, CA, United States of America
| | - Gianluca Lazzi
- Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA, United States of America.,Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA, United States of America.,Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America.,Department of Ophthalmology, University of Southern California, Los Angeles, CA, United States of America
| |
Collapse
|
24
|
Roh H, Yoon YJ, Park JS, Kang DH, Kwak SM, Lee BC, Im M. Fabrication of High-Density Out-of-Plane Microneedle Arrays with Various Heights and Diverse Cross-Sectional Shapes. NANO-MICRO LETTERS 2021; 14:24. [PMID: 34888758 PMCID: PMC8656445 DOI: 10.1007/s40820-021-00778-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Accepted: 11/16/2021] [Indexed: 06/01/2023]
Abstract
Out-of-plane microneedle structures are widely used in various applications such as transcutaneous drug delivery and neural signal recording for brain machine interface. This work presents a novel but simple method to fabricate high-density silicon (Si) microneedle arrays with various heights and diverse cross-sectional shapes depending on photomask pattern designs. The proposed fabrication method is composed of a single photolithography and two subsequent deep reactive ion etching (DRIE) steps. First, a photoresist layer was patterned on a Si substrate to define areas to be etched, which will eventually determine the final location and shape of each individual microneedle. Then, the 1st DRIE step created deep trenches with a highly anisotropic etching of the Si substrate. Subsequently, the photoresist was removed for more isotropic etching; the 2nd DRIE isolated and sharpened microneedles from the predefined trench structures. Depending on diverse photomask designs, the 2nd DRIE formed arrays of microneedles that have various height distributions, as well as diverse cross-sectional shapes across the substrate. With these simple steps, high-aspect ratio microneedles were created in the high density of up to 625 microneedles mm-2 on a Si wafer. Insertion tests showed a small force as low as ~ 172 µN/microneedle is required for microneedle arrays to penetrate the dura mater of a mouse brain. To demonstrate a feasibility of drug delivery application, we also implemented silk microneedle arrays using molding processes. The fabrication method of the present study is expected to be broadly applicable to create microneedle structures for drug delivery, neuroprosthetic devices, and so on.
Collapse
Affiliation(s)
- Hyeonhee Roh
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, South Korea
- Division of Electrical Engineering, College of Engineering, Korea University, Seoul, 02841, South Korea
| | - Young Jun Yoon
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, South Korea
| | - Jin Soo Park
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, South Korea
- Division of Electrical Engineering, College of Engineering, Korea University, Seoul, 02841, South Korea
| | - Dong-Hyun Kang
- Micro/Nano Fabrication Center, KIST, Seoul, 02792, South Korea
| | - Seung Min Kwak
- Micro/Nano Fabrication Center, KIST, Seoul, 02792, South Korea
| | - Byung Chul Lee
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, South Korea
| | - Maesoon Im
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, South Korea.
- Division of Bio-Medical Science & Technology, KIST School, University of Science & Technology (UST), Seoul, 02792, South Korea.
| |
Collapse
|
25
|
Tandon P, Bhaskhar N, Shah N, Madugula S, Grosberg L, Fan VH, Hottowy P, Sher A, Litke AM, Chichilnisky EJ, Mitra S. Automatic Identification of Axon Bundle Activation for Epiretinal Prosthesis. IEEE Trans Neural Syst Rehabil Eng 2021; 29:2496-2502. [PMID: 34784278 PMCID: PMC8860174 DOI: 10.1109/tnsre.2021.3128486] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Objective: Retinal prostheses must be able to activate cells in a selective way in order to restore high-fidelity vision. However, inadvertent activation of far-away retinal ganglion cells (RGCs) through electrical stimulation of axon bundles can produce irregular and poorly controlled percepts, limiting artificial vision. In this work, we aim to provide an algorithmic solution to the problem of detecting axon bundle activation with a bi-directional epiretinal prostheses. Methods: The algorithm utilizes electrical recordings to determine the stimulation current amplitudes above which axon bundle activation occurs. Bundle activation is defined as the axonal stimulation of RGCs with unknown soma and receptive field locations, typically beyond the electrode array. The method exploits spatiotemporal characteristics of electrically-evoked spikes to overcome the challenge of detecting small axonal spikes. Results: The algorithm was validated using large-scale, single-electrode and short pulse, ex vivo stimulation and recording experiments in macaque retina, by comparing algorithmically and manually identified bundle activation thresholds. For 88% of the electrodes analyzed, the threshold identified by the algorithm was within ±10% of the manually identified threshold, with a correlation coefficient of 0.95. Conclusion: This works presents a simple, accurate and efficient algorithm to detect axon bundle activation in epiretinal prostheses. Significance: The algorithm could be used in a closed-loop manner by a future epiretinal prosthesis to reduce poorly controlled visual percepts associated with bundle activation. Activation of distant cells via axonal stimulation will likely occur in other types of retinal implants and cortical implants, and the method may therefore be broadly applicable.
Collapse
|
26
|
Vilkhu RS, Madugula SS, Grosberg LE, Gogliettino AR, Hottowy P, Dabrowski W, Sher A, Litke AM, Mitra S, Chichilnisky EJ. Spatially patterned bi-electrode epiretinal stimulation for axon avoidance at cellular resolution. J Neural Eng 2021; 18. [PMID: 34710857 DOI: 10.1088/1741-2552/ac3450] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 10/28/2021] [Indexed: 11/12/2022]
Abstract
Objective.Epiretinal prostheses are designed to restore vision to people blinded by photoreceptor degenerative diseases by stimulating surviving retinal ganglion cells (RGCs), which carry visual signals to the brain. However, inadvertent stimulation of RGCs at their axons can result in non-focal visual percepts, limiting the quality of artificial vision. Theoretical work has suggested that axon activation can be avoided with current stimulation designed to minimize the second spatial derivative of the induced extracellular voltage along the axon. However, this approach has not been verified experimentally at the resolution of single cells.Approach.In this work, a custom multi-electrode array (512 electrodes, 10μm diameter, 60μm pitch) was used to stimulate and record RGCs in macaque retinaex vivoat single-cell, single-spike resolution. RGC activation thresholds resulting from bi-electrode stimulation, which consisted of bipolar currents simultaneously delivered through two electrodes straddling an axon, were compared to activation thresholds from traditional single-electrode stimulation.Main results.On average, across three retinal preparations, the bi-electrode stimulation strategy reduced somatic activation thresholds (∼21%) while increasing axonal activation thresholds (∼14%), thus favoring selective somatic activation. Furthermore, individual examples revealed rescued selective activation of somas that was not possible with any individual electrode.Significance.This work suggests that a bi-electrode epiretinal stimulation strategy can reduce inadvertent axonal activation at cellular resolution, for high-fidelity artificial vision.
Collapse
Affiliation(s)
- Ramandeep S Vilkhu
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America
| | - Sasidhar S Madugula
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | - Lauren E Grosberg
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | - Alex R Gogliettino
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | - Pawel Hottowy
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow 30-059, Poland
| | - Wladyslaw Dabrowski
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow 30-059, Poland
| | - Alexander Sher
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA, United States of America
| | - Alan M Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA, United States of America
| | - Subhasish Mitra
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America
| | - E J Chichilnisky
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| |
Collapse
|
27
|
Damle S, Carleton M, Kapogianis T, Arya S, Cavichini-Corderio M, Freeman WR, Lo YH, Oesch NW. Minimizing Iridium Oxide Electrodes for High Visual Acuity Subretinal Stimulation. eNeuro 2021; 8:ENEURO.0506-20.2021. [PMID: 34799411 PMCID: PMC8704424 DOI: 10.1523/eneuro.0506-20.2021] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 10/28/2021] [Accepted: 11/15/2021] [Indexed: 11/21/2022] Open
Abstract
Vision loss from diseases of the outer retina, such as age-related macular degeneration, is among the leading causes of irreversible blindness in the world today. The goal of retinal prosthetics is to replace the photo-sensing function of photoreceptors lost in these diseases with optoelectronic hardware to electrically stimulate patterns of retinal activity corresponding to vision. To enable high-resolution retinal prosthetics, the scale of stimulating electrodes must be significantly decreased from current designs; however, this reduces the amount of stimulating current that can be delivered. The efficacy of subretinal stimulation at electrode sizes suitable for high visual acuity retinal prosthesis are not well understood, particularly within the safe charge injection limits of electrode materials. Here, we measure retinal ganglion cell (RGC) responses in a mouse model of blindness to evaluate the stimulation efficacy of 10, 20, and 30 μm diameter iridium oxide electrodes within the electrode charge injection limits, focusing on measures of charge threshold and dynamic range. Stimulation thresholds were lower for smaller electrodes, but larger electrodes could elicit a greater dynamic range of spikes and recruited more ganglion cells within charge injection limits. These findings suggest a practical lower limit for planar electrode size and indicate strategies for maximizing stimulation thresholds and dynamic range.
Collapse
Affiliation(s)
- Samir Damle
- Department of Bioengineering, University of California San Diego, La Jolla, CA 92093
| | - Maya Carleton
- Department of Psychology, University of California San Diego, La Jolla, CA 92093
| | - Theodoros Kapogianis
- Department of Psychology, University of California San Diego, La Jolla, CA 92093
| | - Shaurya Arya
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA 92161
| | - Melina Cavichini-Corderio
- Jacobs Retina Center at Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA 92093
| | - William R Freeman
- Jacobs Retina Center at Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA 92093
| | - Yu-Hwa Lo
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA 92161
| | - Nicholas W Oesch
- Department of Psychology, University of California San Diego, La Jolla, CA 92093
- Jacobs Retina Center at Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA 92093
| |
Collapse
|
28
|
Li W, Xu Z, Wang H, Wu T. The Effect of Electrical Stimulation on the Response of Mouse Retinal Ganglion Cells. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:5704-5708. [PMID: 34892416 DOI: 10.1109/embc46164.2021.9630580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Retinal prostheses can restore the basic visual function of patients with retinal degeneration, which relies on effective electrical stimulation to evoke the physiological activities of retinal ganglion cells (RGCs). Current electrical stimulation strategies suffer from unstable effects and insufficient stimulation positions. Therefore, it is crucial to determine the optimal parameters for precise and safe electrical stimulation. Biphasic voltages (cathode-first) with a pulse width of 25 ms and different amplitudes were used to ex vivo stimulate RGCs of three wild-type (WT) mice using a commercial microelectrode array (MEA) recording system. Based on a facile and efficient spike sorting method, comprehensive statistics of RGCs response types were performed, and the influence of electrical stimulation on RGCs response status was analyzed. There were three types of RGCs response measured from the retinas of three WT mice, and the proportions were calculated to be 91.5%, 3.11% and 5.39%, respectively. This work can provide an in-depth understanding of the internal effects of electrical stimulation and RGCs response, with the potential as a useful guidance for optimizing parameters of electrical stimulation strategies in retinal prostheses.
Collapse
|
29
|
Moleirinho S, Whalen AJ, Fried SI, Pezaris JS. The impact of synchronous versus asynchronous electrical stimulation in artificial vision. J Neural Eng 2021; 18. [PMID: 33900206 DOI: 10.1088/1741-2552/abecf1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Accepted: 03/09/2021] [Indexed: 11/12/2022]
Abstract
Visual prosthesis devices designed to restore sight to the blind have been under development in the laboratory for several decades. Clinical translation continues to be challenging, due in part to gaps in our understanding of critical parameters such as how phosphenes, the electrically-generated pixels of artificial vision, can be combined to form images. In this review we explore the effects that synchronous and asynchronous electrical stimulation across multiple electrodes have in evoking phosphenes. Understanding how electrical patterns influence phosphene generation to control object binding and perception of visual form is fundamental to creation of a clinically successful prosthesis.
Collapse
Affiliation(s)
- Susana Moleirinho
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America
| | - Andrew J Whalen
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America
| | - Shelley I Fried
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America.,Boston VA Healthcare System, Boston, MA, United States of America
| | - John S Pezaris
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America
| |
Collapse
|
30
|
Hadjinicolaou AE, Meffin H, Maturana MI, Cloherty SL, Ibbotson MR. Prosthetic vision: devices, patient outcomes and retinal research. Clin Exp Optom 2021; 98:395-410. [DOI: 10.1111/cxo.12342] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 07/06/2015] [Accepted: 08/04/2015] [Indexed: 12/11/2022] Open
Affiliation(s)
- Alex E Hadjinicolaou
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
| | - Hamish Meffin
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
| | - Matias I Maturana
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- Department of Electrical and Electronic Engineering, The University of Melbourne, Parkville, Victoria, Australia,
| | - Shaun L Cloherty
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
- Department of Electrical and Electronic Engineering, The University of Melbourne, Parkville, Victoria, Australia,
| | - Michael R Ibbotson
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
| |
Collapse
|
31
|
Li W, Qin S, Lu Y, Wang H, Xu Z, Wu T. A facile and comprehensive algorithm for electrical response identification in mouse retinal ganglion cells. PLoS One 2021; 16:e0246547. [PMID: 33705406 PMCID: PMC7951861 DOI: 10.1371/journal.pone.0246547] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Accepted: 01/20/2021] [Indexed: 12/01/2022] Open
Abstract
Retinal prostheses can restore the basic visual function of patients with retinal degeneration, which relies on effective electrical stimulation to evoke the physiological activities of retinal ganglion cells (RGCs). Current electrical stimulation strategies have defects such as unstable effects and insufficient stimulation positions, therefore, it is crucial to determine the optimal pulse parameters for precise and safe electrical stimulation. Biphasic voltages (cathode-first) with a pulse width of 25 ms and different amplitudes were used to ex vivo stimulate RGCs of three wild-type (WT) mice using a commercial microelectrode array (MEA) recording system. An algorithm is developed to automatically realize both spike-sorting and electrical response identification for the spike signals recorded. Measured from three WT mouse retinas, the total numbers of RGC units and responsive RGC units were 1193 and 151, respectively. In addition, the optimal pulse amplitude range for electrical stimulation was determined to be 0.43 V-1.3 V. The processing results of the automatic algorithm we proposed shows high consistency with those using traditional manual processing. We anticipate the new algorithm can not only speed up the elaborate electrophysiological data processing, but also optimize pulse parameters for the electrical stimulation strategy of neural prostheses.
Collapse
Affiliation(s)
- Wanying Li
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Shan Qin
- Shenzhen Shekou People’s Hospital, Shenzhen, China
| | - Yijie Lu
- Shenzhen Aier Eye Hospital, Shenzhen, China
| | - Hao Wang
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Zhen Xu
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- * E-mail: (TZW); (ZX)
| | - Tianzhun Wu
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- * E-mail: (TZW); (ZX)
| |
Collapse
|
32
|
Chenais NAL, Airaghi Leccardi MJI, Ghezzi D. Naturalistic spatiotemporal modulation of epiretinal stimulation increases the response persistence of retinal ganglion cell. J Neural Eng 2021; 18. [DOI: 10.1088/1741-2552/abcd6f] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Accepted: 11/24/2020] [Indexed: 12/24/2022]
|
33
|
Kang JH, Jang YJ, Kim T, Lee BC, Lee SH, Im M. Electric Stimulation Elicits Heterogeneous Responses in ON but Not OFF Retinal Ganglion Cells to Transmit Rich Neural Information. IEEE Trans Neural Syst Rehabil Eng 2021; 29:300-309. [PMID: 33395394 DOI: 10.1109/tnsre.2020.3048973] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Retinal implants electrically stimulate surviving retinal neurons to restore vision in people blinded by outer retinal degeneration. Although the healthy retina is known to transmit a vast amount of visual information to the brain, it has not been studied whether prosthetic vision contains a similar amount of information. Here, we assessed the neural information transmitted by population responses arising in brisk transient (BT) and brisk sustained (BS) subtypes of ON and OFF retinal ganglion cells (RGCs) in the rabbit retina. To correlate the response heterogeneity and the information transmission, we first quantified the cell-to-cell heterogeneity by calculating the spike time tiling coefficient (STTC) across spiking patterns of RGCs in each type. Then, we computed the neural information encoded by the RGC population in a given type. In responses to light stimulation, spiking activities were more heterogeneous in OFF than ON RGCs (STTCAVG = 0.36, 0.45, 0.77 and 0.55 for OFF BT, OFF BS, ON BT, and ON BS, respectively). Interestingly, however, in responses to electric stimulation, both BT and BS subtypes of OFF RGCs showed remarkably homogeneous spiking patterns across cells (STTCAVG = 0.93 and 0.82 for BT and BS, respectively), whereas the two subtypes of ON RGCs showed slightly increased populational heterogeneity compared to light-evoked responses (STTCAVG = 0.71 and 0.63 for BT and BS, respectively). Consequently, the neural information encoded by the electrically-evoked responses of a population of 15 RGCs was substantially lower in the OFF than the ON pathway: OFF BT and BS cells transmit only ~23% and ~53% of the neural information transmitted by their ON counterparts. Together with previously-reported natural spiking activities in ON RGCs, the higher neural information may make ON responses more recognizable, eliciting the biased percepts of bright phosphenes.
Collapse
|
34
|
Paknahad J, Loizos K, Humayun M, Lazzi G. Targeted Stimulation of Retinal Ganglion Cells in Epiretinal Prostheses: A Multiscale Computational Study. IEEE Trans Neural Syst Rehabil Eng 2020; 28:2548-2556. [PMID: 32991284 PMCID: PMC7737501 DOI: 10.1109/tnsre.2020.3027560] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Retinal prostheses aim at restoring partial sight to patients that are blind due to retinal degenerative diseases by electrically stimulating the surviving healthy retinal neurons. Ideally, the electrical stimulation of the retina is intended to induce localized, focused, percepts only; however, some epiretinal implant subjects have reported seeing elongated phosphenes in a single electrode stimulation due to the axonal activation of retinal ganglion cells (RGCs). This issue can be addressed by properly devising stimulation waveforms so that the possibility of inducing axonal activation of RGCs is minimized. While strategies to devise electrical stimulation waveforms to achieve a focal RGCs response have been reported in literature, the underlying mechanisms are not well understood. This article intends to address this gap; we developed morphologically and biophysically realistic computational models of two classified RGCs: D1-bistratified and A2-monostratified. Computational results suggest that the sodium channel band (SOCB) is less sensitive to modulations in stimulation parameters than the distal axon (DA), and DA stimulus threshold is less sensitive to physiological differences among RGCs. Therefore, over a range of RGCs distal axon diameters, short-pulse symmetric biphasic waveforms can enhance the stimulation threshold difference between the SOCB and the DA. Appropriately designed waveforms can avoid axonal activation of RGCs, implying a consequential reduction of undesired strikes in the visual field.
Collapse
|
35
|
Shah NP, Chichilnisky EJ. Computational challenges and opportunities for a bi-directional artificial retina. J Neural Eng 2020; 17:055002. [PMID: 33089827 DOI: 10.1088/1741-2552/aba8b1] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
A future artificial retina that can restore high acuity vision in blind people will rely on the capability to both read (observe) and write (control) the spiking activity of neurons using an adaptive, bi-directional and high-resolution device. Although current research is focused on overcoming the technical challenges of building and implanting such a device, exploiting its capabilities to achieve more acute visual perception will also require substantial computational advances. Using high-density large-scale recording and stimulation in the primate retina with an ex vivo multi-electrode array lab prototype, we frame several of the major computational problems, and describe current progress and future opportunities in solving them. First, we identify cell types and locations from spontaneous activity in the blind retina, and then efficiently estimate their visual response properties by using a low-dimensional manifold of inter-retina variability learned from a large experimental dataset. Second, we estimate retinal responses to a large collection of relevant electrical stimuli by passing current patterns through an electrode array, spike sorting the resulting recordings and using the results to develop a model of evoked responses. Third, we reproduce the desired responses for a given visual target by temporally dithering a diverse collection of electrical stimuli within the integration time of the visual system. Together, these novel approaches may substantially enhance artificial vision in a next-generation device.
Collapse
Affiliation(s)
- Nishal P Shah
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America. Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America. Department of Neurosurgery, Stanford University, Stanford, CA, United States of America. Author to whom any correspondence should be addressed
| | | |
Collapse
|
36
|
Song X, Guo T, Shivdasani MN, Dokos S, Lovell NH, Li X, Qiu S, Li T, Zheng S, Li L. Creation of virtual channels in the retina using synchronous and asynchronous stimulation - a modelling study. J Neural Eng 2020; 17. [PMID: 33086210 DOI: 10.1088/1741-2552/abc3a9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 10/21/2020] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Implantable retinal prostheses aim to provide artificial vision to those suffering from retinal degenerative diseases by electrically stimulating the remaining retinal neurons using a multi-electrode array. The spatial resolution of these devices can be improved by creation of so-called virtual channels (VCs) that are commonly achieved through synchronized stimulation of multiple electrodes. It is largely unclear though if VCs can be created using asynchronous stimulation, which was the primary aim of this study. APPROACH A computational model of multi-layered retina and epi-retinal dual-electrode stimulation was developed to simulate the neural activity of populations of retinal ganglion cells (RGCs) using the VC strategy under both synchronous and asynchronous stimulation conditions. MAIN RESULTS Our simulation suggests that VCs can be created using asynchronous stimulation. VC performance under both synchronous and asynchronous stimulation conditions can be improved by optimizing stimulation parameters such as current intensity, current ratio (α) between two electrodes, electrode spacing and the stimulation waveform. In particular, two VC performance measures; (1) linear displacement of the centroid of RGC activation, and (2) the RGC activation size consistency as a function of different current ratios α, have comparable performance under asynchronous and synchronous stimulation with appropriately selected stimulation parameters. SIGNIFICANCE Our findings support the possibility of creating VCs in the retina under both synchronous and asynchronous stimulation conditions. The results provide theoretical evidence for future retinal prosthesis designs with higher spatial resolution and power efficiency whilst reducing the number of current sources required to achieve these outcomes.
Collapse
Affiliation(s)
- Xiaoyu Song
- , Shanghai Jiao Tong University, Shanghai, 200240, CHINA
| | - Tianruo Guo
- GSBME, UNSW, Sydney, New South Wales, 2052, AUSTRALIA
| | - Mohit N Shivdasani
- Graduate School of Biomedical Engineering, University of New South Wales, Lower Ground, Samuels Building (F25), Kensington, New South Wales, AUSTRALIA
| | - Socrates Dokos
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney 2052, New South Wales, Sydney, New South Wales, 2052, AUSTRALIA
| | - Nigel H Lovell
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Sydney, 2052, AUSTRALIA
| | - Xinxin Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, CHINA
| | - Shirong Qiu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, CHINA
| | - Tong Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, CHINA
| | - Shiwei Zheng
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, CHINA
| | - Liming Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, Shanghai, CHINA
| |
Collapse
|
37
|
Yoon YJ, Lee JI, Jang YJ, An S, Kim JH, Fried SI, Im M. Retinal Degeneration Reduces Consistency of Network-Mediated Responses Arising in Ganglion Cells to Electric Stimulation. IEEE Trans Neural Syst Rehabil Eng 2020; 28:1921-1930. [PMID: 32746297 PMCID: PMC7518787 DOI: 10.1109/tnsre.2020.3003345] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Retinal prostheses use periodic repetition of electrical stimuli to form artificial vision. To enhance the reliability of evoked visual percepts, repeating stimuli need to evoke consistent spiking activity in individual retinal ganglion cells (RGCs). However, it is not well known whether outer retinal degeneration alters the consistency of RGC responses. Hence, here we systematically investigated the trial-to-trial variability in network-mediated responses as a function of the degeneration level. We patch-clamp recorded spikes in ON and OFF types of alpha RGCs from r d10 mice at four different postnatal days (P15, P19, P31, and P60), representing distinct stages of degeneration. To assess the consistency of responses, we analyzed variances in spike count and timing across repeats of the same stimulus delivered multiple times. We found the trial-to-trial variability of network-mediated responses increased considerably as the disease progressed. Compared to responses taken before degeneration onset, those of degenerate retinas showed up to ~70% higher variability (Fano Factor) in spike counts (p < 0.001) and ~95% lower correlation level in spike timing (p < 0.001). These results indicate consistency weakens significantly in electrically-evoked network-mediated responses and therefore raise concerns about the ability of microelectronic retinal implants to elicit consistent visual percepts at advanced stages of retinal degeneration.
Collapse
|
38
|
Shivdasani MN, Evans M, Burns O, Yeoh J, Allen PJ, Nayagam DAX, Villalobos J, Abbott CJ, Luu CD, Opie NL, Sabu A, Saunders AL, McPhedran M, Cardamone L, McGowan C, Maxim V, Williams RA, Fox KE, Cicione R, Garrett DJ, Ahnood A, Ganesan K, Meffin H, Burkitt AN, Prawer S, Williams CE, Shepherd RK. In vivo feasibility of epiretinal stimulation using ultrananocrystalline diamond electrodes. J Neural Eng 2020; 17:045014. [PMID: 32659750 DOI: 10.1088/1741-2552/aba560] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
OBJECTIVE Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing Nitrogen incorporated ultrananocrystalline (N-UNCD) diamond electrodes. APPROACH A prototype implant containing up to twenty-five 120 × 120 µm N-UNCD electrodes was implanted into 16 anaesthetised cats and attached to the retina either using a single tack or via magnetic coupling with a suprachoroidally placed magnet. Multiunit responses to retinal stimulation using charge-balanced biphasic current pulses were recorded acutely in the visual cortex using a multichannel planar array. Several stimulus parameters were varied including; the stimulating electrode, stimulus polarity, phase duration, return configuration and the number of electrodes stimulated simultaneously. MAIN RESULTS The rigid nature of the device and its form factor necessitated complex surgical procedures. Surgeries were considered successful in 10/16 animals and cortical responses to single electrode stimulation obtained in eight animals. Clinical imaging and histological outcomes showed severe retinal trauma caused by the device in situ in many instances. Cortical measures were found to significantly depend on the surgical outcomes of individual experiments, phase duration, return configuration and the number of electrodes stimulated simultaneously, but not stimulus polarity. Cortical thresholds were also found to increase over time within an experiment. SIGNIFICANCE The study successfully demonstrated that an epiretinal prosthesis containing diamond electrodes could produce cortical activity with high precision, albeit only in a small number of cases. Both surgical approaches were highly challenging in terms of reliable and consistent attachment to and stabilisation against the retina, and often resulted in severe retinal trauma. There are key challenges (device form factor and attachment technique) to be resolved for such a device to progress towards clinical application, as current surgical techniques are unable to address these issues.
Collapse
Affiliation(s)
- Mohit N Shivdasani
- Graduate School of Biomedical Engineering, University of New South Wales, Kensington, NSW 2033, Australia. The Bionics Institute of Australia, East Melbourne, VIC 3002, Australia
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
39
|
Haji Ghaffari D, Finn KE, Jeganathan VSE, Patel U, Wuyyuru V, Roy A, Weiland JD. The effect of waveform asymmetry on perception with epiretinal prostheses. J Neural Eng 2020; 17:045009. [PMID: 32590371 DOI: 10.1088/1741-2552/aba07e] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Objective Retinal prosthetic implants have helped improve vision in patients blinded by photoreceptor degeneration. Retinal implant users report improvements in light perception and performing visual tasks, but their ability to perceive shapes and letters is limited due to the low precision of retinal activation, which is exacerbated by axonal stimulation and high perceptual thresholds. A previous in vitro study in our lab used calcium imaging to measure the spatial activity of mouse retinal ganglion cells (RGCs) in response to electrical stimulation. Based on this study, symmetric anodic-first (SA) stimulation effectively avoided axonal activation and asymmetric anodic-first stimulation (AA) with duration ratios (ratio of the anodic to cathodic phase) greater than 10 reduced RGC activation thresholds significantly. Applying these novel stimulation strategies in clinic may increase perception precision and improve the overall patient outcomes. Approach We combined human subject testing and computational modeling to further examine the effect of SA and AA stimuli on perception shapes and thresholds for epiretinal stimulation of RGCs. Main results Threshold measurement in three Argus II participants indicated that AA stimulation could increase perception probabilities compared to a standard symmetric cathodic-first (SC) pulse, and this effect can be intensified by addition of an interphae gap (IPG). Our in silico RGC model predicts lower thresholds with AA and asymmetric cathodic-first (AC) stimuli compared to a SC pulse. This effect was more pronounced at shorter pulse widths. The most effective pulse for threshold reduction with short pulse durations (≤0.12 ms) was AA stimulation with small duration ratios (≤5) and long IPGs (≥2 ms). For the 0.5 ms pulse duration, SC stimulation with IPGs longer than 0.5 ms, or asymmetric stimuli with large duration ratios (≥20) were most effective in threshold reduction. Phosphene shape analysis did not reveal a significant change in percept elongation with SA stimulation. However, there was a significant increase in percept size (P < 0.01) with AA stimulation compared to the standard pulse in one participant. Significane Including asymmetric waveform capability will provide more flexible options for optimization and personalized fitting of retinal implants.
Collapse
Affiliation(s)
- Dorsa Haji Ghaffari
- Department of Biomedical Engineering, Michigan Engineering, University of Michigan, Ann Arbor, MI 48109, United States of America. Biointerfaces Institute, University of Michigan, Ann Arbor, MI 48109, United States of America
| | | | | | | | | | | | | |
Collapse
|
40
|
Werginz P, Wang BY, Chen ZC, Palanker D. On optimal coupling of the 'electronic photoreceptors' into the degenerate retina. J Neural Eng 2020; 17:045008. [PMID: 32613948 PMCID: PMC10948023 DOI: 10.1088/1741-2552/aba0d2] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Objective To restore sight in atrophic age-related macular degeneration, the lost photoreceptors can be replaced with electronic implants, which replicate their two major functions: (1) converting light into an electric signal, and (2) transferring visual information to the secondary neurons in the retinal neural network—the bipolar cells (BC). We study the selectivity of BC activation by subretinal implants and dynamics of their response to pulsatile waveforms in order to optimize the electrical stimulation scheme such that retinal signal processing with 'electronic photoreceptors' remains as close to natural as possible. Approach A multicompartmental model of a BC was implemented to simulate responses of the voltage-gated calcium channels and subsequent synaptic vesicle release under continuous and pulsatile stimuli. We compared the predicted response under various frequencies, pulse durations, and alternating gratings to the corresponding experimental measurements. In addition, electric field was computed for various electrode configurations in a 3-d finite element model to assess the stimulation selectivity via spatial confinement of the field. Main results The modeled BC-mediated retinal responses were, in general, in good agreement with previously published experimental results. Kinetics of the calcium pumps and of the neurotransmitter release in ribbon synapses, which underpin the BC's temporal filtering and rectifying functions, allow mimicking the natural BC response with high frequency pulsatile stimulation, thereby preserving features of the retinal signal processing, such as flicker fusion, adaptation to static stimuli and non-linear summation of subunits in receptive field. Selectivity of the BC stimulation while avoiding direct activation of the downstream neurons (amacrine and ganglion cells—RGCs) is improved with local return electrodes. Significance If the retinal neural network is preserved to a large extent in age-related macular degeneration, selective stimulation of BCs with proper spatial and temporal modulation of the extracellular electric field may retain many features of the natural retinal signal processing and hence allow highly functional restoration of sight.
Collapse
Affiliation(s)
- Paul Werginz
- Institute for Analysis and Scientific Computing, Vienna University of Technology, Vienna, Austria. Author to whom any correspondence should be adressed
| | | | | | | |
Collapse
|
41
|
Abstract
OBJECTIVE Avoidance of the adverse electrochemical reactions at the electrode-electrolyte interface defines the voltage safety window and limits the charge injection capacity (CIC) of an electrode material. For an electrode that is not ideally capacitive, the CIC depends on the waveform of the stimulus. We study the modeling of the charge injection dynamics to optimize the waveforms for efficient neural stimulation within the electrochemical safety limits. APPROACH The charge injection dynamics at the electrode-electrolyte interface is typically characterized by the electrochemical impedance spectrum, and is often approximated by discrete-element circuit models. We compare the modeling of the complete circuit, including a non-linear driver such as a photodiode, based on the harmonic-balance (HB) analysis with the analysis based on various - (discrete-element) approximations. To validate the modeling results, we performed experiments with iridium-oxide electrodes driven by a current source with diodes in parallel, which mimics a photovoltaic circuit. MAIN RESULTS Application of HB analysis based on a full impedance spectrum eliminates the complication of finding the discrete-element circuit model in traditional approaches. HB-based results agree with the experimental data better than the discrete-element circuit. HB technique can be applied not only to demonstrate the circuit response to periodic stimulation, but also to describe the initial transient behavior when a burst waveform is applied. SIGNIFICANCE HB-based circuit analysis accurately describes the dynamics of electrode-electrolyte interfaces and driving circuits for all pulsing schemes. This allows optimizing the stimulus waveform to maximize the CIC, based on the impedance spectrum alone.
Collapse
Affiliation(s)
- Zhijie Charles Chen
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | - Bing-Yi Wang
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
- Department of Physics, Stanford University, Stanford, CA, United States of America
| | - Daniel Palanker
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
- Department of Ophthalmology, Stanford University, Stanford, CA, United States of America
| |
Collapse
|
42
|
Im M, Kim SW. Neurophysiological and medical considerations for better-performing microelectronic retinal prostheses. J Neural Eng 2020; 17:033001. [PMID: 32329755 DOI: 10.1088/1741-2552/ab8ca9] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Maesoon Im
- Center for BioMicrosystems, Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, Republic of Korea. Division of Bio-Medical Science & Technology, KIST School, University of Science and Technology (UST), Seoul, Republic of Korea
| | | |
Collapse
|
43
|
Seo HW, Kim N, Kim S. Fabrication of Subretinal 3D Microelectrodes with Hexagonal Arrangement. MICROMACHINES 2020; 11:mi11050467. [PMID: 32365472 PMCID: PMC7281732 DOI: 10.3390/mi11050467] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2020] [Revised: 04/26/2020] [Accepted: 04/27/2020] [Indexed: 02/01/2023]
Abstract
This study presents the fabrication of three-dimensional (3D) microelectrodes for subretinal stimulation, to accommodate adjacent return electrodes surrounding a stimulating electrode. For retinal prosthetic devices, the arrangement of return electrodes, the electrode size and spacing should be considered together, to reduce the undesired dissipation of electric currents. Here, we applied the hexagonal arrangement to the microelectrode array for the localized activation of retinal cells and better visual acuity. To provide stimuli more efficiently to non-spiking neurons, a 3D structure was created through a customized pressing process, utilizing the elastic property of the materials used in the fabrication processes. The diameter and pitch of the Pt-coated electrodes were 150 μm and 350 μm, respectively, and the height of the protruded electrodes was around 20 μm. The array consisted of 98 hexagonally arranged electrodes, supported by a flexible and transparent polydimethylsiloxane (PDMS) base, with a thickness of 140 μm. Also, the array was coated with 2 μm-thick parylene-C, except the active electrode sites, for more focused stimulation. Finally, the electrochemical properties of the fabricated microelectrodes were characterized, resulting in the mean impedance of 384.87 kΩ at 1 kHz and the charge storage capacity (CSC) of 2.83 mC·cm−2. The fabricated microelectrodes are to be combined with an integrated circuit (IC) for additional in vitro and in vivo experiments.
Collapse
Affiliation(s)
| | | | - Sohee Kim
- Correspondence: ; Tel.: +82-53-785-6217
| |
Collapse
|
44
|
Chen J, Poulaki V, Kim SJ, Eldred WD, Kane S, Gingerich M, Shire DB, Jensen R, DeWalt G, Kaplan HJ, Rizzo JF. Implantation and Extraction of Penetrating Electrode Arrays in Minipig Retinas. Transl Vis Sci Technol 2020; 9:19. [PMID: 32821491 PMCID: PMC7401973 DOI: 10.1167/tvst.9.5.19] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Accepted: 12/31/2019] [Indexed: 12/12/2022] Open
Abstract
Purpose This work was motivated by the goals of demonstrating methods to fabricate and implant large numbers of penetrating arrays into the retina and the feasibility of extraction. Methods Arrays of inactive, three-dimensional (3D) SU-8 structures were microfabricated onto 13-µm polyimide substrates. Standard vitreoretinal surgical techniques were used with an ab externo approach for subretinal implantation of arrays in 12 mini-pigs. In the first three surgeries, different post-geometries were explored, while a preferred design (128-µm tall, 30-µm diameter, 200-µm spacing) was used for the remaining nine implantations. Two arrays were extracted. Funduscopy, optical coherence tomography (OCT) and immunohistochemistry of the retinae were performed. The unoperated eyes and tissue far from implantation served as controls. A thirteenth pig was implanted with a planar array. Results Ten implant surgeries had no significant complication, and two arrays were successfully extracted. One retinal tear occurred after implantation due to too long posts in an early surgery. In “successful” cases, OCT showed close apposition of the arrays to the retina and integration of the posts, the tops of which were positioned at the junction of the inner plexiform and ganglion cells, without significant gliosis. Conclusions These results provide a proof-of-concept that relatively large numbers of 3D posts can be implanted into, and extracted from, the retina of mini-pigs. Our surgical numbers were relatively small, especially for the extractions, and our conclusions must be viewed with that limitation. Our methods are applicable for human surgeries. Translational Relevance This study provides results of implantation and extraction of relatively large numbers of 3D posts from the retina of minipig eyes. If similar technology were used in humans, a 3D array of this type should lower perceptual thresholds, provide safer long-term stimulation, and perhaps provide better perceptual outcomes.
Collapse
Affiliation(s)
- Jinghua Chen
- Department of Ophthalmology, University of Florida, College of Medicine, Gainesville, FL, USA
| | - Vasiliki Poulaki
- Boston VA Healthcare System, Ophthalmology, Jamaica Plain, Boston, MA, USA
| | - Seong-Joon Kim
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| | | | | | | | | | - Ralph Jensen
- Boston VA Healthcare System, Ophthalmology, Jamaica Plain, Boston, MA, USA
| | - Gloria DeWalt
- Department of Biology, Boston University, Boston, MA, USA
| | - Henry J Kaplan
- Department of Ophthalmology and Visual Sciences, University of Louisville, Louisville, KY, USA
| | - Joseph F Rizzo
- Department of Ophthalmology, Harvard Medical School and the Massachusetts Eye and Ear, Boston, MA, USA
| |
Collapse
|
45
|
Yang JW, Yu ZY, Cheng SJ, Chung JHY, Liu X, Wu CY, Lin SF, Chen GY. Graphene Oxide-Based Nanomaterials: An Insight into Retinal Prosthesis. Int J Mol Sci 2020; 21:E2957. [PMID: 32331417 PMCID: PMC7216005 DOI: 10.3390/ijms21082957] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Revised: 04/17/2020] [Accepted: 04/20/2020] [Indexed: 12/27/2022] Open
Abstract
Retinal prosthesis has recently emerged as a treatment strategy for retinopathies, providing excellent assistance in the treatment of age-related macular degeneration (AMD) and retinitis pigmentosa. The potential application of graphene oxide (GO), a highly biocompatible nanomaterial with superior physicochemical properties, in the fabrication of electrodes for retinal prosthesis, is reviewed in this article. This review integrates insights from biological medicine and nanotechnology, with electronic and electrical engineering technological breakthroughs, and aims to highlight innovative objectives in developing biomedical applications of retinal prosthesis.
Collapse
Affiliation(s)
- Jia-Wei Yang
- Department of Electrical and Computer Engineering, College of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu 300, Taiwan; (J.-W.Y.); (S.-J.C.); (S.-F.L.)
- Institute of Biomedical Engineering, College of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu 300, Taiwan;
| | - Zih-Yu Yu
- Institute of Biomedical Engineering, College of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu 300, Taiwan;
| | - Sheng-Jen Cheng
- Department of Electrical and Computer Engineering, College of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu 300, Taiwan; (J.-W.Y.); (S.-J.C.); (S.-F.L.)
- Institute of Biomedical Engineering, College of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu 300, Taiwan;
| | - Johnson H. Y. Chung
- ARC Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, University of Wollongong, Wollongong, NSW 2500, Australia; (J.H.Y.C.); (X.L.)
| | - Xiao Liu
- ARC Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, University of Wollongong, Wollongong, NSW 2500, Australia; (J.H.Y.C.); (X.L.)
| | - Chung-Yu Wu
- Department of Electrical Engineering, National Chiao Tung University, Hsinchu, 300, Taiwan;
| | - Shien-Fong Lin
- Department of Electrical and Computer Engineering, College of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu 300, Taiwan; (J.-W.Y.); (S.-J.C.); (S.-F.L.)
- Institute of Biomedical Engineering, College of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu 300, Taiwan;
| | - Guan-Yu Chen
- Department of Electrical and Computer Engineering, College of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu 300, Taiwan; (J.-W.Y.); (S.-J.C.); (S.-F.L.)
- Institute of Biomedical Engineering, College of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu 300, Taiwan;
- Department of Biological Science and Technology, National Chiao Tung University, Hsinchu 300, Taiwan
| |
Collapse
|
46
|
Tong W, Meffin H, Garrett DJ, Ibbotson MR. Stimulation Strategies for Improving the Resolution of Retinal Prostheses. Front Neurosci 2020; 14:262. [PMID: 32292328 PMCID: PMC7135883 DOI: 10.3389/fnins.2020.00262] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 03/09/2020] [Indexed: 12/17/2022] Open
Abstract
Electrical stimulation using implantable devices with arrays of stimulating electrodes is an emerging therapy for neurological diseases. The performance of these devices depends greatly on their ability to activate populations of neurons with high spatiotemporal resolution. To study electrical stimulation of populations of neurons, retina serves as a useful model because the neural network is arranged in a planar array that is easy to access. Moreover, retinal prostheses are under development to restore vision by replacing the function of damaged light sensitive photoreceptors, which makes retinal research directly relevant for curing blindness. Here we provide a progress review on stimulation strategies developed in recent years to improve the resolution of electrical stimulation in retinal prostheses. We focus on studies performed with explanted retinas, in which electrophysiological techniques are the most advanced. We summarize achievements in improving the spatial and temporal resolution of electrical stimulation of the retina and methods to selectively stimulate neurons with different visual functions. Future directions for retinal prostheses development are also discussed, which could provide insights for other types of neuromodulatory devices in which high-resolution electrical stimulation is required.
Collapse
Affiliation(s)
- Wei Tong
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia
- Department of Optometry and Vision Sciences, Melbourne School of Health Sciences, The University of Melbourne, Melbourne, VIC, Australia
- School of Physics, The University of Melbourne, Melbourne, VIC, Australia
| | - Hamish Meffin
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia
- Department of Optometry and Vision Sciences, Melbourne School of Health Sciences, The University of Melbourne, Melbourne, VIC, Australia
- Department of Biomedical Engineering, The University of Melbourne, Melbourne, VIC, Australia
| | - David J. Garrett
- School of Physics, The University of Melbourne, Melbourne, VIC, Australia
| | - Michael R. Ibbotson
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia
- Department of Optometry and Vision Sciences, Melbourne School of Health Sciences, The University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
47
|
Höfling L, Oesterle J, Berens P, Zeck G. Probing and predicting ganglion cell responses to smooth electrical stimulation in healthy and blind mouse retina. Sci Rep 2020; 10:5248. [PMID: 32251331 PMCID: PMC7090015 DOI: 10.1038/s41598-020-61899-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 02/19/2020] [Indexed: 11/14/2022] Open
Abstract
Retinal implants are used to replace lost photoreceptors in blind patients suffering from retinopathies such as retinitis pigmentosa. Patients wearing implants regain some rudimentary visual function. However, it is severely limited compared to normal vision because non-physiological stimulation strategies fail to selectively activate different retinal pathways at sufficient spatial and temporal resolution. The development of improved stimulation strategies is rendered difficult by the large space of potential stimuli. Here we systematically explore a subspace of potential stimuli by electrically stimulating healthy and blind mouse retina in epiretinal configuration using smooth Gaussian white noise delivered by a high-density CMOS-based microelectrode array. We identify linear filters of retinal ganglion cells (RGCs) by fitting a linear-nonlinear-Poisson (LNP) model. Our stimulus evokes spatially and temporally confined spiking responses in RGC which are accurately predicted by the LNP model. Furthermore, we find diverse shapes of linear filters in the linear stage of the model, suggesting diverse preferred electrical stimuli of RGCs. The linear filter base identified by our approach could provide a starting point of a model-guided search for improved stimuli for retinal prosthetics.
Collapse
Affiliation(s)
- Larissa Höfling
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany
- Graduate Training Centre of Neuroscience, University of Tübingen, Tübingen, Germany
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
- Centre for Integrative Neuroscience, University of Tübingen, Tübingen, Germany
| | - Jonathan Oesterle
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
| | - Philipp Berens
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
- Bernstein Center for Computational Neuroscience, University of Tübingen, Tübingen, Germany
- Department of Computer Science, University of Tübingen, Tübingen, Germany
| | - Günther Zeck
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany.
- Bernstein Center for Computational Neuroscience, University of Tübingen, Tübingen, Germany.
| |
Collapse
|
48
|
Hart WL, Richardson RT, Kameneva T, Thompson AC, Wise AK, Fallon JB, Stoddart PR, Needham K. Combined optogenetic and electrical stimulation of auditory neurons increases effective stimulation frequency-an in vitro study. J Neural Eng 2020; 17:016069. [PMID: 31923907 DOI: 10.1088/1741-2552/ab6a68] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
OBJECTIVE The performance of neuroprostheses, including cochlear and retinal implants, is currently constrained by the spatial resolution of electrical stimulation. Optogenetics has improved the spatial control of neurons in vivo but lacks the fast-temporal dynamics required for auditory and retinal signalling. The objective of this study is to demonstrate that combining optical and electrical stimulation in vitro could address some of the limitations associated with each of the stimulus modes when used independently. APPROACH The response of murine auditory neurons expressing ChR2-H134 to combined optical and electrical stimulation was characterised using whole cell patch clamp electrophysiology. MAIN RESULTS Optogenetic costimulation produces a three-fold increase in peak firing rate compared to optical stimulation alone and allows spikes to be evoked by combined subthreshold optical and electrical inputs. Subthreshold optical depolarisation also facilitated spiking in auditory neurons for periods of up to 30 ms without evidence of wide-scale Na+ inactivation. SIGNIFICANCE These findings may contribute to the development of spatially and temporally selective optogenetic-based neuroprosthetics and complement recent developments in 'fast opsins'.
Collapse
Affiliation(s)
- William L Hart
- ARC Training Centre in Biodevices, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| | - Rachael T Richardson
- The Bionics Institute, East Melbourne, VIC 3002, Australia
- Department of Surgery (Otolaryngology), University of Melbourne, The Royal Victorian Eye and Ear Hospital, East Melbourne, VIC 3002, Australia
- Medical Bionics Department, University of Melbourne, East Melbourne, VIC 3002, Australia
| | - Tatiana Kameneva
- Swinburne University of Technology, Hawthorn VIC 3122, Australia
| | | | - Andrew K Wise
- The Bionics Institute, East Melbourne, VIC 3002, Australia
- Department of Surgery (Otolaryngology), University of Melbourne, The Royal Victorian Eye and Ear Hospital, East Melbourne, VIC 3002, Australia
- Medical Bionics Department, University of Melbourne, East Melbourne, VIC 3002, Australia
| | - James B Fallon
- The Bionics Institute, East Melbourne, VIC 3002, Australia
- Department of Surgery (Otolaryngology), University of Melbourne, The Royal Victorian Eye and Ear Hospital, East Melbourne, VIC 3002, Australia
- Medical Bionics Department, University of Melbourne, East Melbourne, VIC 3002, Australia
| | - Paul R Stoddart
- ARC Training Centre in Biodevices, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| | - Karina Needham
- Department of Surgery (Otolaryngology), University of Melbourne, The Royal Victorian Eye and Ear Hospital, East Melbourne, VIC 3002, Australia
- Author to whom any correspondence should be addressed
| |
Collapse
|
49
|
Abstract
Developments of new strategies to restore vision and improving on current strategies by harnessing new advancements in material and electrical sciences, and biological and genetic-based technologies are of upmost health priorities around the world. Federal and private entities are spending billions of dollars on visual prosthetics technologies. This review describes the most current and state-of-the-art bioengineering technologies to restore vision. This includes a thorough description of traditional electrode-based visual prosthetics that have improved substantially since early prototypes. Recent advances in molecular and synthetic biology have transformed vision-assisted technologies; For example, optogenetic technologies that introduce light-responsive proteins offer excellent resolution but cortical applications are restricted by fiber implantation and tissue damage. Other stimulation modalities, such as magnetic fields, have been explored to achieve non-invasive neuromodulation. Miniature magnetic coils are currently being developed to activate select groups of neurons. Magnetically-responsive nanoparticles or exogenous proteins can significantly enhance the coupling between external electromagnetic devices and any neurons affiliated with these modifications. The need to minimize cytotoxic effects for nanoparticle-based therapies will likely restrict the number of usable materials. Nevertheless, advances in identifying and utilizing proteins that respond to magnetic fields may lead to non-invasive, cell-specific stimulation and may overcome many of the limitations that currently exist with other methods. Finally, sensory substitution systems also serve as viable visual prostheses by converting visual input to auditory and somatosensory stimuli. This review also discusses major challenges in the field and offers bioengineering strategies to overcome those.
Collapse
Affiliation(s)
- Alexander Farnum
- Department of Biomedical Engineering, College of Engineering, Michigan State University, East Lansing, MI, United States
- Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI, United States
| | - Galit Pelled
- Department of Biomedical Engineering, College of Engineering, Michigan State University, East Lansing, MI, United States
- Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI, United States
- Department of Radiology, College of Human Medicine, Michigan State University, East Lansing, MI, United States
| |
Collapse
|
50
|
Damle S, Liu YH, Arya S, Oesch NW, Lo YH. Vertically integrated photo junction-field-effect transistor pixels for retinal prosthesis. BIOMEDICAL OPTICS EXPRESS 2020; 11:55-67. [PMID: 32010499 PMCID: PMC6968743 DOI: 10.1364/boe.11.000055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Revised: 11/20/2019] [Accepted: 11/24/2019] [Indexed: 06/10/2023]
Abstract
Optoelectronic retinal prostheses transduce light into electrical current for neural stimulation. We introduce a novel optoelectronic pixel architecture consisting of a vertically integrated photo junction-field-effect transistor (Photo-JFET) and neural stimulating electrode. Experimental measurements demonstrate that optically addressed Photo-JFET pixels utilize phototransistive gain to produce a broad range of neural stimulation current and can effectively stimulate retinal neurons in vitro. The compact nature of the Photo-JFET pixel can enable high resolution retinal prostheses with the smallest reported optoelectronic pixel size to help restore high visual acuity in patients with degenerative retinal diseases.
Collapse
Affiliation(s)
- Samir Damle
- Department of Bioengineering, University of California San Diego, 9500 Gilman Drive La Jolla, CA 92093, USA
| | - Yu-Hsin Liu
- Nanovision Biosciences, Inc., 3366 N. Torrey Pines Court, Suite 220, La Jolla, CA 92037, USA
| | - Shaurya Arya
- Department of Electrical and Computer Engineering, University of California San Diego, Engineer Ln, La Jolla, CA 92161, USA
| | - Nicholas W. Oesch
- Department of Psychology, University of California San Diego, 9500 Gilman Drive, CA 92093, USA
- Jacobs Retina Center at Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, 9415 Campus Point Drive San Diego, CA 92093, USA
| | - Yu-Hwa Lo
- Jacobs Retina Center at Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, 9415 Campus Point Drive San Diego, CA 92093, USA
| |
Collapse
|