1
|
Abbott JR, Jeakle EN, Haghighi P, Usoro JO, Sturgill BS, Wu Y, Geramifard N, Radhakrishna R, Patnaik S, Nakajima S, Hess J, Mehmood Y, Devata V, Vijayakumar G, Sood A, Doan Thai TT, Dogra K, Hernandez-Reynoso AG, Pancrazio JJ, Cogan SF. Planar amorphous silicon carbide microelectrode arrays for chronic recording in rat motor cortex. Biomaterials 2024; 308:122543. [PMID: 38547834 PMCID: PMC11065583 DOI: 10.1016/j.biomaterials.2024.122543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 03/05/2024] [Accepted: 03/19/2024] [Indexed: 04/21/2024]
Abstract
Chronic implantation of intracortical microelectrode arrays (MEAs) capable of recording from individual neurons can be used for the development of brain-machine interfaces. However, these devices show reduced recording capabilities under chronic conditions due, at least in part, to the brain's foreign body response (FBR). This creates a need for MEAs that can minimize the FBR to possibly enable long-term recording. A potential approach to reduce the FBR is the use of MEAs with reduced cross-sectional geometries. Here, we fabricated 4-shank amorphous silicon carbide (a-SiC) MEAs and implanted them into the motor cortex of seven female Sprague-Dawley rats. Each a-SiC MEA shank was 8 μm thick by 20 μm wide and had sixteen sputtered iridium oxide film (SIROF) electrodes (4 per shank). A-SiC was chosen as the fabrication base for its high chemical stability, good electrical insulation properties, and amenability to thin film fabrication. Electrochemical analysis and neural recordings were performed weekly for 4 months. MEAs were characterized pre-implantation in buffered saline and in vivo using electrochemical impedance spectroscopy and cyclic voltammetry at 50 mV/s and 50,000 mV/s. Neural recordings were analyzed for single unit activity. At the end of the study, animals were sacrificed for immunohistochemical analysis. We observed statistically significant, but small, increases in 1 and 30 kHz impedance values and 50,000 mV/s charge storage capacity over the 16-week implantation period. Slow sweep 50 mV/s CV and 1 Hz impedance did not significantly change over time. Impedance values increased from 11.6 MΩ to 13.5 MΩ at 1 Hz, 1.2 MΩ-2.9 MΩ at 1 kHz, and 0.11 MΩ-0.13 MΩ at 30 kHz over 16 weeks. The median charge storage capacity of the implanted electrodes at 50 mV/s was 58.1 mC/cm2 on week 1 and 55.9 mC/cm2 on week 16, and at 50,000 mV/s, 4.27 mC/cm2 on week 1 and 5.93 mC/cm2 on week 16. Devices were able to record neural activity from 92% of all active channels at the beginning of the study, At the study endpoint, a-SiC devices were still recording single-unit activity on 51% of electrochemically active electrode channels. In addition, we observed that the signal-to-noise ratio experienced a small decline of -0.19 per week. We also classified observed units as fast and slow repolarizing based on the trough-to-peak time. Although the overall presence of single units declined, fast and slow repolarizing units declined at a similar rate. At recording electrode depth, immunohistochemistry showed minimal tissue response to the a-SiC devices, as indicated by statistically insignificant differences in activated glial cell response between implanted brains slices and contralateral sham slices at 150 μm away from the implant location, as evidenced by GFAP staining. NeuN staining revealed the presence of neuronal cell bodies close to the implantation site, again statistically not different from a contralateral sham slice. These results warrant further investigation of a-SiC MEAs for future long-term implantation neural recording studies.
Collapse
Affiliation(s)
- Justin R Abbott
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Eleanor N Jeakle
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Pegah Haghighi
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Joshua O Usoro
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Brandon S Sturgill
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Yupeng Wu
- Department of Materials Science and Engineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Negar Geramifard
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Rahul Radhakrishna
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Sourav Patnaik
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Shido Nakajima
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Jordan Hess
- School of Behavioral and Brain Sciences, The University of Texas at Dallas, Richardson, TX, United States
| | - Yusef Mehmood
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Veda Devata
- Department of Chemistry and Biochemistry, The University of Texas at Dallas, Richardson, TX, United States
| | - Gayathri Vijayakumar
- School of Behavioral and Brain Sciences, The University of Texas at Dallas, Richardson, TX, United States
| | - Armaan Sood
- School of Behavioral and Brain Sciences, The University of Texas at Dallas, Richardson, TX, United States
| | - Teresa Thuc Doan Thai
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Komal Dogra
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Ana G Hernandez-Reynoso
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Joseph J Pancrazio
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Stuart F Cogan
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States.
| |
Collapse
|
2
|
Shen K, Chen O, Edmunds JL, Piech DK, Maharbiz MM. Translational opportunities and challenges of invasive electrodes for neural interfaces. Nat Biomed Eng 2023; 7:424-442. [PMID: 37081142 DOI: 10.1038/s41551-023-01021-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 02/15/2023] [Indexed: 04/22/2023]
Abstract
Invasive brain-machine interfaces can restore motor, sensory and cognitive functions. However, their clinical adoption has been hindered by the surgical risk of implantation and by suboptimal long-term reliability. In this Review, we highlight the opportunities and challenges of invasive technology for clinically relevant electrophysiology. Specifically, we discuss the characteristics of neural probes that are most likely to facilitate the clinical translation of invasive neural interfaces, describe the neural signals that can be acquired or produced by intracranial electrodes, the abiotic and biotic factors that contribute to their failure, and emerging neural-interface architectures.
Collapse
Affiliation(s)
- Konlin Shen
- University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering, Berkeley, CA, USA.
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA, USA.
| | - Oliver Chen
- Department of Electrical Engineering and Computer Science, University of California, Berkeley, CA, USA
| | - Jordan L Edmunds
- Department of Electrical Engineering and Computer Science, University of California, Berkeley, CA, USA
| | - David K Piech
- University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering, Berkeley, CA, USA
| | - Michel M Maharbiz
- Department of Electrical Engineering and Computer Science, University of California, Berkeley, CA, USA
- Department of Bioengineering, University of California, Berkeley, CA, USA
- Chan-Zuckerberg Biohub, San Francisco, CA, USA
| |
Collapse
|
3
|
Mariello M, Kim K, Wu K, Lacour SP, Leterrier Y. Recent Advances in Encapsulation of Flexible Bioelectronic Implants: Materials, Technologies, and Characterization Methods. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2201129. [PMID: 35353928 DOI: 10.1002/adma.202201129] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 03/13/2022] [Indexed: 06/14/2023]
Abstract
Bioelectronic implantable systems (BIS) targeting biomedical and clinical research should combine long-term performance and biointegration in vivo. Here, recent advances in novel encapsulations to protect flexible versions of such systems from the surrounding biological environment are reviewed, focusing on material strategies and synthesis techniques. Considerable effort is put on thin-film encapsulation (TFE), and specifically organic-inorganic multilayer architectures as a flexible and conformal alternative to conventional rigid cans. TFE is in direct contact with the biological medium and thus must exhibit not only biocompatibility, inertness, and hermeticity but also mechanical robustness, conformability, and compatibility with the manufacturing of microfabricated devices. Quantitative characterization methods of the barrier and mechanical performance of the TFE are reviewed with a particular emphasis on water-vapor transmission rate through electrical, optical, or electrochemical principles. The integrability and functionalization of TFE into functional bioelectronic interfaces are also discussed. TFE represents a must-have component for the next-generation bioelectronic implants with diagnostic or therapeutic functions in human healthcare and precision medicine.
Collapse
Affiliation(s)
- Massimo Mariello
- Laboratory for Processing of Advanced Composites (LPAC), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, CH-1015, Switzerland
| | - Kyungjin Kim
- Bertarelli Foundation Chair in Neuroprosthetic Technology, Laboratory for Soft Bioelectronic Interfaces, Institute of Electrical and MicroEngineering, Institute of Bioengineering, Centre for Neuroprosthetics, École Polytechnique Fédérale de Lausanne, Geneva, Switzerland
| | - Kangling Wu
- Bertarelli Foundation Chair in Neuroprosthetic Technology, Laboratory for Soft Bioelectronic Interfaces, Institute of Electrical and MicroEngineering, Institute of Bioengineering, Centre for Neuroprosthetics, École Polytechnique Fédérale de Lausanne, Geneva, Switzerland
| | - Stéphanie P Lacour
- Bertarelli Foundation Chair in Neuroprosthetic Technology, Laboratory for Soft Bioelectronic Interfaces, Institute of Electrical and MicroEngineering, Institute of Bioengineering, Centre for Neuroprosthetics, École Polytechnique Fédérale de Lausanne, Geneva, Switzerland
| | - Yves Leterrier
- Laboratory for Processing of Advanced Composites (LPAC), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, CH-1015, Switzerland
| |
Collapse
|
4
|
Balakrishnan G, Song J, Mou C, Bettinger CJ. Recent Progress in Materials Chemistry to Advance Flexible Bioelectronics in Medicine. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2106787. [PMID: 34751987 PMCID: PMC8917047 DOI: 10.1002/adma.202106787] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 10/15/2021] [Indexed: 05/09/2023]
Abstract
Designing bioelectronic devices that seamlessly integrate with the human body is a technological pursuit of great importance. Bioelectronic medical devices that reliably and chronically interface with the body can advance neuroscience, health monitoring, diagnostics, and therapeutics. Recent major efforts focus on investigating strategies to fabricate flexible, stretchable, and soft electronic devices, and advances in materials chemistry have emerged as fundamental to the creation of the next generation of bioelectronics. This review summarizes contemporary advances and forthcoming technical challenges related to three principal components of bioelectronic devices: i) substrates and structural materials, ii) barrier and encapsulation materials, and iii) conductive materials. Through notable illustrations from the literature, integration and device fabrication strategies and associated challenges for each material class are highlighted.
Collapse
Affiliation(s)
| | - Jiwoo Song
- Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA
| | - Chenchen Mou
- Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA
| | | |
Collapse
|
5
|
Vėbraitė I, Hanein Y. Soft Devices for High-Resolution Neuro-Stimulation: The Interplay Between Low-Rigidity and Resolution. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 3:675744. [PMID: 35047928 PMCID: PMC8757739 DOI: 10.3389/fmedt.2021.675744] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Accepted: 05/14/2021] [Indexed: 12/27/2022] Open
Abstract
The field of neurostimulation has evolved over the last few decades from a crude, low-resolution approach to a highly sophisticated methodology entailing the use of state-of-the-art technologies. Neurostimulation has been tested for a growing number of neurological applications, demonstrating great promise and attracting growing attention in both academia and industry. Despite tremendous progress, long-term stability of the implants, their large dimensions, their rigidity and the methods of their introduction and anchoring to sensitive neural tissue remain challenging. The purpose of this review is to provide a concise introduction to the field of high-resolution neurostimulation from a technological perspective and to focus on opportunities stemming from developments in materials sciences and engineering to reduce device rigidity while optimizing electrode small dimensions. We discuss how these factors may contribute to smaller, lighter, softer and higher electrode density devices.
Collapse
Affiliation(s)
- Ieva Vėbraitė
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Yael Hanein
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
6
|
Nguyen CK, Abbott JR, Negi S, Cogan SF. Evaluation of Amorphous Silicon Carbide on Utah Electrode Arrays by Thermal Accelerated Aging . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:6623-6626. [PMID: 34892626 DOI: 10.1109/embc46164.2021.9629701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Long-term microelectrode arrays (MEAs) are essential devices for studying neural activity and stimulating neurons for treating neurological disorders or for recording neural activity to control prosthesis. However, practical use of MEAs is impeded by unreliable chronic stability inside the host body. We are proposing to implement amorphous silicon carbide (a-SiC) as a replacement for the current standard practice of using Parylene-C encapsulation on commercial Utah electrode arrays (UEAs) manufactured by Blackrock Neurotech. By using thermal accelerated aging (TAA), we can theoretically evaluate the lifetime stabilities in comparatively short time. After 255 days at 87°C in phosphate-buffered saline (PBS), a device has theoretically reached ~22 years at 37°C in PBS. We report on a study of an a-SiC UEA using stability criteria of impedance (Z1kHz < 70 kΩ) and cathodal charge storage capacity (CSCc > 10 mC/cm2). At 255 days, no total electrode failures have been observed.Clinical Relevance- This research demonstrates the suitability of a-SiC to encapsulate MEAs during under long-term stability in saline environments.
Collapse
|
7
|
Kuliasha CA, Judy JW. The Materials Science Foundation Supporting the Microfabrication of Reliable Polyimide-Metal Neuroelectronic Interfaces. ADVANCED MATERIALS TECHNOLOGIES 2021; 6:2100149. [PMID: 34632047 PMCID: PMC8494240 DOI: 10.1002/admt.202100149] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Indexed: 05/24/2023]
Abstract
Thin-film polyimide-metal neuroelectronic interfaces hold the potential to alleviate many neurological disorders. However, their long-term reliability is challenged by an aggressive implant environment that causes delamination and degradation of critical materials, resulting in a degradation or complete loss of implant function. Herein, a rigorous and in-depth analysis is presented on the fabrication and modification of critical materials in these thin-film neural interfaces. Special attention is given to improving the interfacial adhesion between thin films and processing modifications to maximize device reliability. Fundamental material analyses are performed on the polyimide substrate and adhesion-promotion candidates, including amorphous silicon carbide (a-SiC:H), amorphous carbon, and silane coupling agents. Basic fabrication rules are identified to markedly improve polyimide self-adhesion, including optimizing the polyimide-cure profile and maximizing high-energy surface activation. In general, oxide-forming materials are identified as poor adhesive aids to polyimide without targeted modifications. Methods are identified to incorporate effective a-SiC:H interfacial layers to improve metal adherence to polyimide, in addition to examples of alloying between adjacent material layers that can impact the trace resistivity and long-term reliability of the thin-film interfaces. The provided rationale and consequences of key decisions made should promote more reproducible science using robust and reliable neuroelectronic technology.
Collapse
Affiliation(s)
- Cary A Kuliasha
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL 32611, USA
| | - Jack W Judy
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL 32611, USA
| |
Collapse
|
8
|
Evaluation methods for long-term reliability of polymer-based implantable biomedical devices. Biomed Eng Lett 2021; 11:97-105. [PMID: 34150346 DOI: 10.1007/s13534-021-00188-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Revised: 03/24/2021] [Accepted: 04/05/2021] [Indexed: 01/04/2023] Open
Abstract
Long-term reliability of implantable biomedical devices is a critical issue for their practical usefulness and successful translation into clinical application. Reliability is particularly of great concern for recently demonstrated devices based on new materials typically relying on polymeric thin films and microfabrication process. While reliability testing protocol has been well-established for traditional metallic packages, common evaluation methods for polymer-based microdevices has yet to be agreed upon, even though various testing methods have been proposed. This article is aiming to summarize the evaluation methods on long-term reliability of emerging biomedical implants based on polymeric thin-films in terms of their theories and implementation with specific focus on difference from the traditional metallic packages.
Collapse
|
9
|
Intracellular detection and communication of a wireless chip in cell. Sci Rep 2021; 11:5967. [PMID: 33727598 PMCID: PMC7966781 DOI: 10.1038/s41598-021-85268-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 02/22/2021] [Indexed: 12/16/2022] Open
Abstract
The rapid growth and development of technology has had significant implications for healthcare, personalized medicine, and our understanding of biology. In this work, we leverage the miniaturization of electronics to realize the first demonstration of wireless detection and communication of an electronic device inside a cell. This is a significant forward step towards a vision of non-invasive, intracellular wireless platforms for single-cell analyses. We demonstrate that a 25 \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\upmu $$\end{document}μm wireless radio frequency identification (RFID) device can not only be taken up by a mammalian cell but can also be detected and specifically identified externally while located intracellularly. The S-parameters and power delivery efficiency of the electronic communication system is quantified before and after immersion in a biological environment; the results show distinct electrical responses for different RFID tags, allowing for classification of cells by examining the electrical output noninvasively. This versatile platform can be adapted for realization of a broad modality of sensors and actuators. This work precedes and facilitates the development of long-term intracellular real-time measurement systems for personalized medicine and furthering our understanding of intrinsic biological behaviors. It helps provide an advanced technique to better assess the long-term evolution of cellular physiology as a result of drug and disease stimuli in a way that is not feasible using current methods.
Collapse
|
10
|
Abstract
The lifetime of neural implants is strongly dependent on packaging due to the aqueous and biochemically aggressive nature of the body. Over the last decade, there has been a drive towards neuromodulatory implants which are wireless and approaching millimeter-scales with increasing electrode count. A so-far unrealized goal for these new types of devices is an in-vivo lifetime comparable to a sizable fraction of a healthy patient's lifetime (>10-20 years). Existing, approved medical implants commonly encapsulate components in metal enclosures (e.g. titanium) with brazed ceramic inserts for electrode feedthrough. It is unclear how amenable the traditional approach is to the simultaneous goals of miniaturization, increased channel count, and wireless communication. Ceramic materials have also played a significant role in traditional medical implants due to their dielectric properties, corrosion resistance, biocompatibility, and high strength, but are not as commonly used for housing materials due to their brittleness and the difficulty they present in creating complex housing geometries. However, thin-film technology has opened new opportunities for ceramics processing. Thin films derived largely from the semiconductor industry can be deposited and patterned in new ways, have conductivities which can be altered during manufacturing to provide conductors as well as insulators, and can be used to fabricate flexible substrates. In this review, we give an overview of packaging for neural implants, with an emphasis on how ceramic materials have been utilized in medical device packaging, as well as how ceramic thin-film micromachining and processing may be further developed to create truly reliable, miniaturized, neural implants.
Collapse
Affiliation(s)
- Konlin Shen
- University of California, Berkeley-University of California, San Francisco Graduate Program in Bioengineering, Berkeley, CA, United States of America
| | | |
Collapse
|
11
|
Huang TW, Kamins T, Chen ZC, Wang BY, Bhuckory M, Galambos L, Ho E, Ling T, Afshar S, Shin A, Zuckerman V, Harris JS, Mathieson K, Palanker D. Vertical-junction photodiodes for smaller pixels in retinal prostheses. J Neural Eng 2021; 18. [PMID: 33592588 DOI: 10.1088/1741-2552/abe6b8] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 02/16/2021] [Indexed: 01/27/2023]
Abstract
Objective.To restore central vision in patients with atrophic age-related macular degeneration, we replace the lost photoreceptors with photovoltaic pixels, which convert light into current and stimulate the secondary retinal neurons. Clinical trials demonstrated prosthetic acuity closely matching the sampling limit of the 100 μm pixels, and hence smaller pixels are required for improving visual acuity. However, with smaller flat bipolar pixels, the electric field penetration depth and the photodiode responsivity significantly decrease, making the device inefficient. Smaller pixels may be enabled by (1) increasing the diode responsivity using vertical p-n junctions and (2) directing the electric field in tissue vertically. Here, we demonstrate such novel photodiodes and test the retinal stimulation in a vertical electric field.Approach.Arrays of silicon photodiodes of 55, 40, 30, and 20 μm in width, with vertical p-n junctions, were fabricated. The electric field in the retina was directed vertically using a common return electrode at the edge of the devices. Optical and electronic performance of the diodes was characterized in-vitro, and retinal stimulation threshold measured by recording the visually evoked potentials (VEPs) in rats with retinal degeneration.Main results.The photodiodes exhibited sufficiently low dark current (<10 pA) and responsivity at 880 nm wavelength as high as 0.51 A/W, with 85% internal quantum efficiency, independent of pixel size. Field mapping in saline demonstrated uniformity of the pixel performance in the array. The full-field stimulation threshold was as low as 0.057±0.029 mW/mm2with 10 ms pulses, independent of pixel size.Significance.Photodiodes with vertical p-n junctions demonstrated excellent charge collection efficiency independent of pixel size, down to 20 μm. Vertically-oriented electric field provides a stimulation threshold that is independent of pixel size. These results are the first steps in validation of scaling down the photovoltaic pixels for subretinal stimulation.
Collapse
Affiliation(s)
- Tiffany W Huang
- Electrical Engineering, Stanford University, 450 Serra Mall, Stanford, California, 94305, UNITED STATES
| | - Theodore Kamins
- Electrical Engineering, Stanford University, 450 Serra Mall, Stanford, California, 94305, UNITED STATES
| | - Zhijie Charles Chen
- Electrical Engineering, Stanford University, 452 Lomita Mall, Rm 136, Stanford, California, 94305-6104, UNITED STATES
| | - Bing-Yi Wang
- Physics, Stanford University, 450 Serra Mall, Stanford, 94305, UNITED STATES
| | - Mohajeet Bhuckory
- Ophthalmology, Stanford University, 450 Serra Mall, Stanford, California, 94305, UNITED STATES
| | - Ludwig Galambos
- Electrical Engineering, Stanford University, 450 Serra Mall, Stanford, California, 94305, UNITED STATES
| | - Elton Ho
- Physics, Stanford University, 452 Lomita Mall, Stanford, California, 94305, UNITED STATES
| | - Tong Ling
- Ophthalmology, Hansen Experimental Physics Laboratory, Stanford University, 450 Serra Mall, Stanford, California, 94305, UNITED STATES
| | - Sean Afshar
- Electrical Engineering, Stanford University, 450 Serra Mall, Stanford, California, 94305-6104, UNITED STATES
| | - Andrew Shin
- Materials Science and Engineering, Stanford University, 420 Via Palou Mall, Stanford, California, 94305, UNITED STATES
| | - Valentina Zuckerman
- Hansen Experimental Physics Laboratory, Stanford University, 450 Serra Mall, Stanford, California, 94305, UNITED STATES
| | - James S Harris
- Electrical Engineering, Stanford University, 450 Serra Mall, Stanford, California, 94305, UNITED STATES
| | - Keith Mathieson
- Institute of Photonics, University of Strathclyde, 16 Richmond St, Glasgow, G1 1XQ, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Daniel Palanker
- Ophthalmology, Hansen Experimental Physics Laboratory, Stanford University, 452 Lomita Mall, Stanford, California, 94305, UNITED STATES
| |
Collapse
|
12
|
Silicon Carbide and MRI: Towards Developing a MRI Safe Neural Interface. MICROMACHINES 2021; 12:mi12020126. [PMID: 33530350 PMCID: PMC7911642 DOI: 10.3390/mi12020126] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 01/22/2021] [Accepted: 01/23/2021] [Indexed: 12/11/2022]
Abstract
An essential method to investigate neuromodulation effects of an invasive neural interface (INI) is magnetic resonance imaging (MRI). Presently, MRI imaging of patients with neural implants is highly restricted in high field MRI (e.g., 3 T and higher) due to patient safety concerns. This results in lower resolution MRI images and, consequently, degrades the efficacy of MRI imaging for diagnostic purposes in these patients. Cubic silicon carbide (3C-SiC) is a biocompatible wide-band-gap semiconductor with a high thermal conductivity and magnetic susceptibility compatible with brain tissue. It also has modifiable electrical conductivity through doping level control. These properties can improve the MRI compliance of 3C-SiC INIs, specifically in high field MRI scanning. In this work, the MRI compliance of epitaxial SiC films grown on various Si wafers, used to implement a monolithic neural implant (all-SiC), was studied. Via finite element method (FEM) and Fourier-based simulations, the specific absorption rate (SAR), induced heating, and image artifacts caused by the portion of the implant within a brain tissue phantom located in a 7 T small animal MRI machine were estimated and measured. The specific goal was to compare implant materials; thus, the effect of leads outside the tissue was not considered. The results of the simulations were validated via phantom experiments in the same 7 T MRI system. The simulation and experimental results revealed that free-standing 3C-SiC films had little to no image artifacts compared to silicon and platinum reference materials inside the MRI at 7 T. In addition, FEM simulations predicted an ~30% SAR reduction for 3C-SiC compared to Pt. These initial simulations and experiments indicate an all-SiC INI may effectively reduce MRI induced heating and image artifacts in high field MRI. In order to evaluate the MRI safety of a closed-loop, fully functional all-SiC INI as per ISO/TS 10974:2018 standard, additional research and development is being conducted and will be reported at a later date.
Collapse
|
13
|
Bio-Compatibility and Bio-Insulation of Implantable Electrode Prosthesis Ameliorated by A-174 Silane Primed Parylene-C Deposited Embedment. MICROMACHINES 2020; 11:mi11121064. [PMID: 33266050 PMCID: PMC7761135 DOI: 10.3390/mi11121064] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 11/24/2020] [Accepted: 11/29/2020] [Indexed: 11/16/2022]
Abstract
Microelectrodes for pain management, neural prosthesis or assistances have a huge medical demand, such as the application of pain management chip or retinal prosthesis addressed on age-related macular degeneration (AMD) and the retinitis pigmentosa (RP). Due to lifelong implanted in human body and direct adhesion of neural tissues, the electrodes and associated insulation materials should possess an ideal bio-compatibility, including non-cytotoxicity and no safety concern elicited by immune responses. Our goal intended to develop retinal prosthesis, an electrical circuit chip used for assisting neural electrons transmission on retina and ameliorating the retinal disability. Therefore, based on the ISO 10993 guidance for implantable medical devices, the electrode prosthesis with insulation material has to conduct bio-compatibility assessment including cytotoxicity, hemolysis, (skin) irritation and pathological implantation examinations. In this study, we manufactured inter-digitated electrode (IDE) chips mimic the electrode prosthesis through photolithography. The titanium and platinum composites were deposited onto a silicon wafer to prepare an electric circuit to mimic the electrode used in retinal prosthesis manufacture, which further be encapsulated to examine the bio-compatibility in compliance with ISO 10993 and ASTM guidance specifically for implantable medical devices. Parylene-C, polyimide and silicon carbide were selected as materials for electrode encapsulation in comparison. Our data revealed parylene-C coating showed a significant excellence on bio-insulation and bio-compatibility specifically addressed on implantable neuron stimulatory devices and provided an economic procedure to package the electrode prosthesis. Therefore, parylene C encapsulation should serve as a consideration for future application on retinal prosthesis manufacture and examination.
Collapse
|
14
|
Shire DB, Gingerich MD, Wong PI, Skvarla M, Cogan SF, Chen J, Wang W, Rizzo JF. Micro-Fabrication of Components for a High-Density Sub-Retinal Visual Prosthesis. MICROMACHINES 2020; 11:mi11100944. [PMID: 33086504 PMCID: PMC7603138 DOI: 10.3390/mi11100944] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2020] [Revised: 10/10/2020] [Accepted: 10/13/2020] [Indexed: 01/30/2023]
Abstract
We present a retrospective of unique micro-fabrication problems and solutions that were encountered through over 10 years of retinal prosthesis product development, first for the Boston Retinal Implant Project initiated at the Massachusetts Institute of Technology and at Harvard Medical School’s teaching hospital, the Massachusetts Eye and Ear—and later at the startup company Bionic Eye Technologies, by some of the same personnel. These efforts culminated in the fabrication and assembly of 256+ channel visual prosthesis devices having flexible multi-electrode arrays that were successfully implanted sub-retinally in mini-pig animal models as part of our pre-clinical testing program. We report on the processing of the flexible multi-layered, planar and penetrating high-density electrode arrays, surgical tools for sub-retinal implantation, and other parts such as coil supports that facilitated the implantation of the peri-ocular device components. We begin with an overview of the implantable portion of our visual prosthesis system design, and describe in detail the micro-fabrication methods for creating the parts of our system that were assembled outside of our hermetically-sealed electronics package. We also note the unique surgical challenges that sub-retinal implantation of our micro-fabricated components presented, and how some of those issues were addressed through design, materials selection, and fabrication approaches.
Collapse
Affiliation(s)
- Douglas B. Shire
- Bionic Eye Technologies, Inc., Ithaca, NY 14850, USA; (M.D.G.); (P.I.W.)
- Correspondence: ; Tel.: +1-607-339-7085
| | | | - Patricia I. Wong
- Bionic Eye Technologies, Inc., Ithaca, NY 14850, USA; (M.D.G.); (P.I.W.)
| | - Michael Skvarla
- Cornell NanoScale Science and Technology Facility, Ithaca, NY 14853, USA;
| | - Stuart F. Cogan
- Department of Bioengineering, University of Texas, Dallas, Richardson, TX 75080, USA;
| | - Jinghua Chen
- Department of Ophthalmology, University of Florida, Gainesville, FL 32611, USA;
| | - Wei Wang
- Department of Ophthalmology, University of Louisville, Louisville, KY 40292, USA;
| | | |
Collapse
|
15
|
Stability Performance Analysis of Various Packaging Materials and Coating Strategies for Chronic Neural Implants under Accelerated, Reactive Aging Tests. MICROMACHINES 2020; 11:mi11090810. [PMID: 32858951 PMCID: PMC7570179 DOI: 10.3390/mi11090810] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 08/21/2020] [Accepted: 08/23/2020] [Indexed: 12/13/2022]
Abstract
Reliable packaging for implantable neural prosthetic devices in body fluids is a long-standing challenge for devices’ chronic applications. This work studied the stability of Parylene C (PA), SiO2, and Si3N4 packages and coating strategies on tungsten wires using accelerated, reactive aging tests in three solutions: pH 7.4 phosphate-buffered saline (PBS), PBS + 30 mM H2O2, and PBS + 150 mM H2O2. Different combinations of coating thicknesses and deposition methods were studied at various testing temperatures. Analysis of the preliminary data shows that the pinholes/defects, cracks, and interface delamination are the main attributes of metal erosion and degradation in reactive aging solutions. Failure at the interface of package and metal is the dominating factor in the wire samples with open tips.
Collapse
|
16
|
Yang W, Gong Y, Li W. A Review: Electrode and Packaging Materials for Neurophysiology Recording Implants. Front Bioeng Biotechnol 2020; 8:622923. [PMID: 33585422 PMCID: PMC7873964 DOI: 10.3389/fbioe.2020.622923] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 12/10/2020] [Indexed: 01/28/2023] Open
Abstract
To date, a wide variety of neural tissue implants have been developed for neurophysiology recording from living tissues. An ideal neural implant should minimize the damage to the tissue and perform reliably and accurately for long periods of time. Therefore, the materials utilized to fabricate the neural recording implants become a critical factor. The materials of these devices could be classified into two broad categories: electrode materials as well as packaging and substrate materials. In this review, inorganic (metals and semiconductors), organic (conducting polymers), and carbon-based (graphene and carbon nanostructures) electrode materials are reviewed individually in terms of various neural recording devices that are reported in recent years. Properties of these materials, including electrical properties, mechanical properties, stability, biodegradability/bioresorbability, biocompatibility, and optical properties, and their critical importance to neural recording quality and device capabilities, are discussed. For the packaging and substrate materials, different material properties are desired for the chronic implantation of devices in the complex environment of the body, such as biocompatibility and moisture and gas hermeticity. This review summarizes common solid and soft packaging materials used in a variety of neural interface electrode designs, as well as their packaging performances. Besides, several biopolymers typically applied over the electrode package to reinforce the mechanical rigidity of devices during insertion, or to reduce the immune response and inflammation at the device-tissue interfaces are highlighted. Finally, a benchmark analysis of the discussed materials and an outlook of the future research trends are concluded.
Collapse
Affiliation(s)
- Weiyang Yang
- Microtechnology Lab, Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, United States
| | - Yan Gong
- Microtechnology Lab, Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, United States
| | - Wen Li
- Microtechnology Lab, Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, United States
| |
Collapse
|
17
|
Ho E, Lei X, Flores T, Lorach H, Huang T, Galambos L, Kamins T, Harris J, Mathieson K, Palanker D. Characteristics of prosthetic vision in rats with subretinal flat and pillar electrode arrays. J Neural Eng 2019; 16:066027. [PMID: 31341094 PMCID: PMC7192047 DOI: 10.1088/1741-2552/ab34b3] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Objective Retinal prostheses aim to restore sight by electrically stimulating the surviving retinal neurons. In clinical trials of the current retinal implants, prosthetic visual acuity does not exceed 20/550. However, to provide meaningful restoration of central vision in patients blinded by age-related macular degeneration (AMD), prosthetic acuity should be at least 20/200, necessitating a pixel pitch of about 50 μm or lower. With such small pixels, stimulation thresholds are high due to limited penetration of electric field into tissue. Here, we address this challenge with our latest photovoltaic arrays and evaluate their performance in vivo. Approach We fabricated photovoltaic arrays with 55 and 40 μm pixels (a) in flat geometry, and (b) with active electrodes on 10 μm tall pillars. The arrays were implanted subretinally into rats with degenerate retina. Stimulation thresholds and grating acuity were evaluated using measurements of the visually evoked potentials (VEP). Main results With 55 μm pixels, we measured grating acuity of 48 ± 11 μm, which matches the linear pixel pitch of the hexagonal array. This geometrically corresponds to a visual acuity of 20/192 in a human eye, matching the threshold of legal blindness in the US (20/200). With pillar electrodes, the irradiance threshold was nearly halved, and duration threshold reduced by more than three-fold, compared to flat pixels. With 40 μm pixels, VEP was too low for reliable measurements of the grating acuity, even with pillar electrodes. Significance While being helpful for treating a complete loss of sight, current prosthetic technologies are insufficient for addressing the leading cause of untreatable visual impairment—AMD. Subretinal photovoltaic arrays may provide sufficient visual acuity for restoration of central vision in patients blinded by AMD.
Collapse
Affiliation(s)
- Elton Ho
- Department of Physics, Stanford University, Stanford, CA 94305, United States of America. Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305, United States of America
| | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Deku F, Cohen Y, Joshi-Imre A, Kanneganti A, Gardner TJ, Cogan SF. Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording. J Neural Eng 2019; 15:016007. [PMID: 28952963 DOI: 10.1088/1741-2552/aa8f8b] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVE Foreign body response to indwelling cortical microelectrodes limits the reliability of neural stimulation and recording, particularly for extended chronic applications in behaving animals. The extent to which this response compromises the chronic stability of neural devices depends on many factors including the materials used in the electrode construction, the size, and geometry of the indwelling structure. Here, we report on the development of microelectrode arrays (MEAs) based on amorphous silicon carbide (a-SiC). APPROACH This technology utilizes a-SiC for its chronic stability and employs semiconductor manufacturing processes to create MEAs with small shank dimensions. The a-SiC films were deposited by plasma enhanced chemical vapor deposition and patterned by thin-film photolithographic techniques. To improve stimulation and recording capabilities with small contact areas, we investigated low impedance coatings on the electrode sites. The assembled devices were characterized in phosphate buffered saline for their electrochemical properties. MAIN RESULTS MEAs utilizing a-SiC as both the primary structural element and encapsulation were fabricated successfully. These a-SiC MEAs had 16 penetrating shanks. Each shank has a cross-sectional area less than 60 µm2 and electrode sites with a geometric surface area varying from 20 to 200 µm2. Electrode coatings of TiN and SIROF reduced 1 kHz electrode impedance to less than 100 kΩ from ~2.8 MΩ for 100 µm2 Au electrode sites and increased the charge injection capacities to values greater than 3 mC cm-2. Finally, we demonstrated functionality by recording neural activity from basal ganglia nucleus of Zebra Finches and motor cortex of rat. SIGNIFICANCE The a-SiC MEAs provide a significant advancement in the development of microelectrodes that over the years has relied on silicon platforms for device manufacture. These flexible a-SiC MEAs have the potential for decreased tissue damage and reduced foreign body response. The technique is promising and has potential for clinical translation and large scale manufacturing.
Collapse
Affiliation(s)
- Felix Deku
- Department of Bioengineering, University of Texas at Dallas, 800 W. Campbell Road, Richardson, TX 75080, United States of America
| | | | | | | | | | | |
Collapse
|
19
|
Park JH, Song Z, Lee GY, Jeong SM, Kang MJ, Pyun JC. Hypersensitive electrochemical immunoassays based on highly N-doped silicon carbide (SiC) electrode. Anal Chim Acta 2019; 1073:30-38. [DOI: 10.1016/j.aca.2019.04.054] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 04/22/2019] [Accepted: 04/23/2019] [Indexed: 12/20/2022]
|
20
|
Schöler M, Brecht C, Wellmann PJ. Annealing-Induced Changes in the Nature of Point Defects in Sublimation-Grown Cubic Silicon Carbide. MATERIALS 2019; 12:ma12152487. [PMID: 31390722 PMCID: PMC6695932 DOI: 10.3390/ma12152487] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 07/15/2019] [Accepted: 08/02/2019] [Indexed: 11/16/2022]
Abstract
In recent years, cubic silicon carbide (3C-SiC) has gained increasing interest as semiconductor material for energy saving and optoelectronic applications, such as intermediate-band solar cells, photoelectrochemical water splitting, and quantum key distribution, just to name a few. All these applications critically depend on further understanding of defect behavior at the atomic level and the possibility to actively control distinct defects. In this work, dopants as well as intrinsic defects were introduced into the 3C-SiC material in situ during sublimation growth. A series of isochronal temperature treatments were performed in order to investigate the temperature-dependent annealing behavior of point defects. The material was analyzed by temperature-dependent photoluminescence (PL) measurements. In our study, we found a variation in the overall PL intensity which can be considered as an indication of annealing-induced changes in structure, composition or concentration of point defects. Moreover, a number of dopant-related as well as intrinsic defects were identified. Among these defects, there were strong indications for the presence of the negatively charged nitrogen vacancy complex (NC–VSi)−, which is considered a promising candidate for spin qubits.
Collapse
Affiliation(s)
- Michael Schöler
- Crystal Growth Lab, Materials Department 6 (i-meet), Friedrich-Alexander University Erlangen-Nürnberg (FAU), Martensstr. 7, D-91058 Erlangen, Germany
| | - Clemens Brecht
- Crystal Growth Lab, Materials Department 6 (i-meet), Friedrich-Alexander University Erlangen-Nürnberg (FAU), Martensstr. 7, D-91058 Erlangen, Germany
| | - Peter J Wellmann
- Crystal Growth Lab, Materials Department 6 (i-meet), Friedrich-Alexander University Erlangen-Nürnberg (FAU), Martensstr. 7, D-91058 Erlangen, Germany.
| |
Collapse
|
21
|
Ahn SH, Jeong J, Kim SJ. Emerging Encapsulation Technologies for Long-Term Reliability of Microfabricated Implantable Devices. MICROMACHINES 2019; 10:E508. [PMID: 31370259 PMCID: PMC6723304 DOI: 10.3390/mi10080508] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Revised: 07/20/2019] [Accepted: 07/29/2019] [Indexed: 01/11/2023]
Abstract
The development of reliable long-term encapsulation technologies for implantable biomedical devices is of paramount importance for the safe and stable operation of implants in the body over a period of several decades. Conventional technologies based on titanium or ceramic packaging, however, are not suitable for encapsulating microfabricated devices due to their limited scalability, incompatibility with microfabrication processes, and difficulties with miniaturization. A variety of emerging materials have been proposed for encapsulation of microfabricated implants, including thin-film inorganic coatings of Al2O3, HfO2, SiO2, SiC, and diamond, as well as organic polymers of polyimide, parylene, liquid crystal polymer, silicone elastomer, SU-8, and cyclic olefin copolymer. While none of these materials have yet been proven to be as hermetic as conventional metal packages nor widely used in regulatory approved devices for chronic implantation, a number of studies have demonstrated promising outcomes on their long-term encapsulation performance through a multitude of fabrication and testing methodologies. The present review article aims to provide a comprehensive, up-to-date overview of the long-term encapsulation performance of these emerging materials with a specific focus on publications that have quantitatively estimated the lifetime of encapsulation technologies in aqueous environments.
Collapse
Affiliation(s)
- Seung-Hee Ahn
- Department of Electrical and Computer Engineering, Seoul National University, Seoul 08826, Korea
| | - Joonsoo Jeong
- Department of Biomedical Engineering, School of Medicine, Pusan National University, Yangsan 50612, Korea.
| | - Sung June Kim
- Department of Electrical and Computer Engineering, Seoul National University, Seoul 08826, Korea.
- Institute of Aging, College of Medicine, Seoul National University, Seoul 08826, Korea.
| |
Collapse
|
22
|
Joshi-Imre A, Black BJ, Abbott J, Kanneganti A, Rihani R, Chakraborty B, Danda VR, Maeng J, Sharma R, Rieth L, Negi S, Pancrazio JJ, Cogan SF. Chronic recording and electrochemical performance of amorphous silicon carbide-coated Utah electrode arrays implanted in rat motor cortex. J Neural Eng 2019; 16:046006. [DOI: 10.1088/1741-2552/ab1bc8] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
23
|
Deku F, Mohammed S, Joshi-Imre A, Maeng J, Danda V, Gardner TJ, Cogan SF. Effect of oxidation on intrinsic residual stress in amorphous silicon carbide films. J Biomed Mater Res B Appl Biomater 2018; 107:1654-1661. [PMID: 30321479 DOI: 10.1002/jbm.b.34258] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Revised: 08/26/2018] [Accepted: 09/16/2018] [Indexed: 11/11/2022]
Abstract
The change in residual stress in plasma enhanced chemical vapor deposition amorphous silicon carbide (a-SiC:H) films exposed to air and wet ambient environments is investigated. A close relationship between stress change and deposition condition is identified from mechanical and chemical characterization of a-SiC:H films. Evidence of amorphous silicon carbide films reacting with oxygen and water vapor in the ambient environment are presented. The effect of deposition parameters on oxidation and stress variation in a-SiC:H film is studied. It is found that the films deposited at low temperature or power are susceptible to oxidation and undergo a notable increase in compressive stress over time. Furthermore, the films deposited at sufficiently high temperature (≥325 C) and power density (≥0.2 W cm-2 ) do not exhibit pronounced oxidation or temporal stress variation. These results serve as the basis for developing amorphous silicon carbide based dielectric encapsulation for implantable medical devices. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1654-1661, 2019.
Collapse
Affiliation(s)
- Felix Deku
- Department of Bioengineering, University of Texas at Dallas, Richardson, Texas
| | - Shakil Mohammed
- Department of Materials Science and Engineering, University of Texas at Dallas, Richardson, Texas
| | | | - Jimin Maeng
- Department of Bioengineering, University of Texas at Dallas, Richardson, Texas
| | - Vindhya Danda
- Department of Bioengineering, University of Texas at Dallas, Richardson, Texas
| | - Timothy J Gardner
- Department of Biology and Department of Biomedical Engineering, Boston University, Boston, Massachusetts
| | - Stuart F Cogan
- Department of Bioengineering, University of Texas at Dallas, Richardson, Texas
| |
Collapse
|
24
|
Bernardin EK, Frewin CL, Everly R, Ul Hassan J, Saddow SE. Demonstration of a Robust All-Silicon-Carbide Intracortical Neural Interface. MICROMACHINES 2018; 9:E412. [PMID: 30424345 PMCID: PMC6187288 DOI: 10.3390/mi9080412] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 08/11/2018] [Accepted: 08/12/2018] [Indexed: 01/09/2023]
Abstract
Intracortical neural interfaces (INI) have made impressive progress in recent years but still display questionable long-term reliability. Here, we report on the development and characterization of highly resilient monolithic silicon carbide (SiC) neural devices. SiC is a physically robust, biocompatible, and chemically inert semiconductor. The device support was micromachined from p-type SiC with conductors created from n-type SiC, simultaneously providing electrical isolation through the resulting p-n junction. Electrodes possessed geometric surface area (GSA) varying from 496 to 500 K μm². Electrical characterization showed high-performance p-n diode behavior, with typical turn-on voltages of ~2.3 V and reverse bias leakage below 1 nArms. Current leakage between adjacent electrodes was ~7.5 nArms over a voltage range of -50 V to 50 V. The devices interacted electrochemically with a purely capacitive relationship at frequencies less than 10 kHz. Electrode impedance ranged from 675 ± 130 kΩ (GSA = 496 µm²) to 46.5 ± 4.80 kΩ (GSA = 500 K µm²). Since the all-SiC devices rely on the integration of only robust and highly compatible SiC material, they offer a promising solution to probe delamination and biological rejection associated with the use of multiple materials used in many current INI devices.
Collapse
Affiliation(s)
- Evans K Bernardin
- Department of Biomedical Engineering, University of South Florida, Tampa, FL 33620, USA.
| | - Christopher L Frewin
- Department of Bioengineering, University of Texas at Dallas, Dallas, TX 75080, USA.
| | - Richard Everly
- Nanotechnology Research and Education Center @ USF, Tampa, FL 33617, USA.
| | - Jawad Ul Hassan
- Department of Physics, Chemistry and Biology (IFM), Linköping University, SE-581 83 Linköping, Sweden.
| | - Stephen E Saddow
- Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA.
| |
Collapse
|
25
|
Won SM, Song E, Zhao J, Li J, Rivnay J, Rogers JA. Recent Advances in Materials, Devices, and Systems for Neural Interfaces. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2018; 30:e1800534. [PMID: 29855089 DOI: 10.1002/adma.201800534] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 02/28/2018] [Indexed: 06/08/2023]
Abstract
Technologies capable of establishing intimate, long-lived optical/electrical interfaces to neural systems will play critical roles in neuroscience research and in the development of nonpharmacological treatments for neurological disorders. The development of high-density interfaces to 3D populations of neurons across entire tissue systems in living animals, including human subjects, represents a grand challenge for the field, where advanced biocompatible materials and engineered structures for electrodes and light emitters will be essential. This review summarizes recent progress in these directions, with an emphasis on the most promising demonstrated concepts, materials, devices, and systems. The article begins with an overview of electrode materials with enhanced electrical and/or mechanical performance, in forms ranging from planar films, to micro/nanostructured surfaces, to 3D porous frameworks and soft composites. Subsequent sections highlight integration with active materials and components for multiplexed addressing, local amplification, wireless data transmission, and power harvesting, with multimodal operation in soft, shape-conformal systems. These advances establish the foundations for scalable architectures in optical/electrical neural interfaces of the future, where a blurring of the lines between biotic and abiotic systems will catalyze profound progress in neuroscience research and in human health/well-being.
Collapse
Affiliation(s)
- Sang Min Won
- Department of Electrical and Computer Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Urbana, IL, 61801, USA
| | - Enming Song
- Department of Materials Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Northwestern University, Evanston, IL, 60208, USA
| | - Jianing Zhao
- Department of Mechanical Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Urbana, IL, 61801, USA
| | - Jinghua Li
- Department of Materials Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Northwestern University, Evanston, IL, 60208, USA
| | - Jonathan Rivnay
- Department of Biomedical Engineering, Simpson Querrey Institute for Nanobiotechnology, Northwestern University, Evanston, IL, 60208, USA
| | - John A Rogers
- Center for Bio-Integrated Electronics, Department of Materials Science and Engineering, Biomedical Engineering, Chemistry, Mechanical Engineering, Electrical Engineering and Computer Science, and Neurological Surgery, Simpson Querrey Institute for Nano/biotechnology, McCormick School of Engineering and Feinberg School of Medicine, Northwestern University, Evanston, IL, 60208, USA
| |
Collapse
|
26
|
Ferlauto L, Airaghi Leccardi MJI, Chenais NAL, Gilliéron SCA, Vagni P, Bevilacqua M, Wolfensberger TJ, Sivula K, Ghezzi D. Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis. Nat Commun 2018; 9:992. [PMID: 29520006 PMCID: PMC5843635 DOI: 10.1038/s41467-018-03386-7] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Accepted: 02/08/2018] [Indexed: 01/18/2023] Open
Abstract
Retinal prostheses have been developed to fight blindness in people affected by outer retinal layer dystrophies. To date, few hundred patients have received a retinal implant. Inspired by intraocular lenses, we have designed a foldable and photovoltaic wide-field epiretinal prosthesis (named POLYRETINA) capable of stimulating wireless retinal ganglion cells. Here we show that within a visual angle of 46.3 degrees, POLYRETINA embeds 2215 stimulating pixels, of which 967 are in the central area of 5 mm, it is foldable to allow implantation through a small scleral incision, and it has a hemispherical shape to match the curvature of the eye. We demonstrate that it is not cytotoxic and respects optical and thermal safety standards; accelerated ageing shows a lifetime of at least 2 years. POLYRETINA represents significant progress towards the improvement of both visual acuity and visual field with the same device, a current challenging issue in the field.
Collapse
Affiliation(s)
- Laura Ferlauto
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics, Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Marta Jole Ildelfonsa Airaghi Leccardi
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics, Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Naïg Aurelia Ludmilla Chenais
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics, Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Samuel Charles Antoine Gilliéron
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics, Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Paola Vagni
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics, Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Michele Bevilacqua
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics, Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Thomas J Wolfensberger
- Department of Ophthalmology, University of Lausanne, Hôpital Ophtalmique Jules-Gonin, Fondation Asile des Aveugles, Lausanne, Switzerland
| | - Kevin Sivula
- Laboratory for Molecular Engineering of Optoelectronic Nanomaterials, Institute of Chemical Sciences and Engineering, School of Basic Science, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Diego Ghezzi
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics, Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
| |
Collapse
|
27
|
Pancrazio JJ, Deku F, Ghazavi A, Stiller AM, Rihani R, Frewin CL, Varner VD, Gardner TJ, Cogan SF. Thinking Small: Progress on Microscale Neurostimulation Technology. Neuromodulation 2017; 20:745-752. [PMID: 29076214 PMCID: PMC5943060 DOI: 10.1111/ner.12716] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Revised: 08/28/2017] [Accepted: 09/19/2017] [Indexed: 01/08/2023]
Abstract
OBJECTIVES Neural stimulation is well-accepted as an effective therapy for a wide range of neurological disorders. While the scale of clinical devices is relatively large, translational, and pilot clinical applications are underway for microelectrode-based systems. Microelectrodes have the advantage of stimulating a relatively small tissue volume which may improve selectivity of therapeutic stimuli. Current microelectrode technology is associated with chronic tissue response which limits utility of these devices for neural recording and stimulation. One approach for addressing the tissue response problem may be to reduce physical dimensions of the device. "Thinking small" is a trend for the electronics industry, and for implantable neural interfaces, the result may be a device that can evade the foreign body response. MATERIALS AND METHODS This review paper surveys our current understanding pertaining to the relationship between implant size and tissue response and the state-of-the-art in ultrasmall microelectrodes. A comprehensive literature search was performed using PubMed, Web of Science (Clarivate Analytics), and Google Scholar. RESULTS The literature review shows recent efforts to create microelectrodes that are extremely thin appear to reduce or even eliminate the chronic tissue response. With high charge capacity coatings, ultramicroelectrodes fabricated from emerging polymers, and amorphous silicon carbide appear promising for neurostimulation applications. CONCLUSION We envision the emergence of robust and manufacturable ultramicroelectrodes that leverage advanced materials where the small cross-sectional geometry enables compliance within tissue. Nevertheless, future testing under in vivo conditions is particularly important for assessing the stability of thin film devices under chronic stimulation.
Collapse
Affiliation(s)
- Joseph J. Pancrazio
- Department of Bioengineering, 800 W. Campbell Road, BSB 13.633, The University of Texas at Dallas, Richardson, TX, 75080, USA
| | - Felix Deku
- Department of Bioengineering, 800 W. Campbell Road, BSB 13.633, The University of Texas at Dallas, Richardson, TX, 75080, USA
| | - Atefeh Ghazavi
- Department of Bioengineering, 800 W. Campbell Road, BSB 13.633, The University of Texas at Dallas, Richardson, TX, 75080, USA
| | - Allison M. Stiller
- Department of Bioengineering, 800 W. Campbell Road, BSB 13.633, The University of Texas at Dallas, Richardson, TX, 75080, USA
| | - Rashed Rihani
- Department of Bioengineering, 800 W. Campbell Road, BSB 13.633, The University of Texas at Dallas, Richardson, TX, 75080, USA
| | - Christopher L. Frewin
- Department of Bioengineering, 800 W. Campbell Road, BSB 13.633, The University of Texas at Dallas, Richardson, TX, 75080, USA
| | - Victor D. Varner
- Department of Bioengineering, 800 W. Campbell Road, BSB 13.633, The University of Texas at Dallas, Richardson, TX, 75080, USA
| | | | - Stuart F. Cogan
- Department of Bioengineering, 800 W. Campbell Road, BSB 13.633, The University of Texas at Dallas, Richardson, TX, 75080, USA
| |
Collapse
|
28
|
Daschner R, Greppmaier U, Kokelmann M, Rudorf S, Rudorf R, Schleehauf S, Wrobel WG. Laboratory and clinical reliability of conformally coated subretinal implants. Biomed Microdevices 2017; 19:7. [PMID: 28124761 PMCID: PMC5269461 DOI: 10.1007/s10544-017-0147-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Despite recent developments and new treatments in ophthalmology there is nothing available to cure retinal degenerations like Retinitis Pigmentosa (RP) yet. One of the most advanced approaches to treat people that have gone blind due to RP is to replace the function of the degenerated photoreceptors by a microelectronic neuroprosthetic device. Basically, this subretinal active implant transforms the incoming light into electric pulses to stimulate the remaining cells of the retina. The functional time of such devices is a crucial aspect. In this paper the laboratory and clinical reliability of the two active subretinal implants Alpha IMS and Alpha AMS is presented. Based on clinical data the median operating life of the Alpha AMS is estimated to be 3.3 years with a one-sided lower 75 % confidence level of 2.0 years. This data shows a significant improvement of the device lifetime compared to the previous device Alpha IMS which shows a median lifetime of 0.6 years with a lower confidence bound (75 %) of 0.5 years. The results are in good agreement with laboratory data from accelerated aging tests of the implant components, showing an estimated median lifetime for Alpha IMS components of 0.7 years compared to the improved lifetime of Alpha AMS of 4.7 years.
Collapse
Affiliation(s)
- Renate Daschner
- Retina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany.
| | - Udo Greppmaier
- Retina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany
| | - Martin Kokelmann
- Retina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany
| | - Sandra Rudorf
- Retina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany
| | - Ralf Rudorf
- Retina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany
| | | | - Walter G Wrobel
- Retina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany
| |
Collapse
|