• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4624131)   Today's Articles (6043)   Subscriber (49410)
For: Gutmann C, Shaikh N, Shenoy BS, Shaymasunder Bhat N, Keni LG, K N C. Wear estimation of hip implants with varying chamfer geometry at the trunnion junction: a finite element analysis. Biomed Phys Eng Express 2023;9. [PMID: 36716460 DOI: 10.1088/2057-1976/acb710] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Accepted: 01/30/2023] [Indexed: 02/01/2023]
Number Cited by Other Article(s)
1
Amjad M, Badshah S, Ahmad S, Badshah M, Jan S, Yasir M, Akram W, Alam Shah I, Muhammad R, Khan MI, Yasmeen T. Finite element modeling of stress distribution and safety factors in a Ti-27Nb alloy hip implant under real-world physiological loading scenarios. PLoS One 2024;19:e0300270. [PMID: 39106270 DOI: 10.1371/journal.pone.0300270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Accepted: 02/25/2024] [Indexed: 08/09/2024]  Open
2
Fatemi M, Bahrami Z, Bahraminasab M, Nabizadeh Chianeh F. Optimizing functionally graded tibial components for total knee replacements: a finite element analysis and multi-objective optimization study. Comput Methods Biomech Biomed Engin 2024:1-19. [PMID: 38804561 DOI: 10.1080/10255842.2024.2358358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 05/07/2024] [Indexed: 05/29/2024]
3
Dipu MNH, Apu MH, Chowdhury PP. Identification of the effective crane hook's cross-section by incorporating finite element method and programming language. Heliyon 2024;10:e29918. [PMID: 38765096 PMCID: PMC11101710 DOI: 10.1016/j.heliyon.2024.e29918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 03/29/2024] [Accepted: 04/17/2024] [Indexed: 05/21/2024]  Open
4
Bologna FA, Putame G, Audenino AL, Terzini M. Understanding the role of head size and neck length in micromotion generation at the taper junction in total hip arthroplasty. Sci Rep 2024;14:6397. [PMID: 38493233 PMCID: PMC10944531 DOI: 10.1038/s41598-024-57017-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 03/13/2024] [Indexed: 03/18/2024]  Open
5
K N C, Schmidt Genannt Waldschmidt N, Corda JV, Shenoy B S, Shetty S, Keni LG, Bhat N S, Nikam N, Mihcin S. Patient-specific finite element analysis for assessing hip fracture risk in aging populations. Biomed Phys Eng Express 2024;10:035006. [PMID: 38437729 DOI: 10.1088/2057-1976/ad2ff3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Accepted: 03/04/2024] [Indexed: 03/06/2024]
6
Keni LG, Satish Shenoy B, Chethan KN, Hegde P, Prakashini K, Tamagawa M, Zuber M. CFD investigation of multiple peristaltic waves in a 3D unobstructed ureter. Biomed Phys Eng Express 2024;10:025011. [PMID: 38227968 DOI: 10.1088/2057-1976/ad1f02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 01/16/2024] [Indexed: 01/18/2024]
7
Corda JV, K N C, Bhat N S, Shetty S, Shenoy B S, Zuber M. Finite element analysis of elliptical shaped stem profile of hip prosthesis using dynamic loading conditions. Biomed Phys Eng Express 2023;9:065028. [PMID: 37769637 DOI: 10.1088/2057-1976/acfe14] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 09/28/2023] [Indexed: 10/03/2023]
8
Winter P, Fritsch E, Tschernig T, Goebel L, Wolf M, Müller M, Weise JJ, Orth P, Landgraeber S. Accuracy of Personalized Computed Tomographic 3D Templating for Acetabular Cup Placement in Revision Arthroplasty. MEDICINA (KAUNAS, LITHUANIA) 2023;59:1608. [PMID: 37763727 PMCID: PMC10536197 DOI: 10.3390/medicina59091608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 08/29/2023] [Accepted: 09/01/2023] [Indexed: 09/29/2023]
9
Alpkaya AT, Mihcin S. Dynamic computational wear model of PEEK-on-XLPE bearing couple in total hip replacements. Med Eng Phys 2023:104006. [PMID: 37308373 DOI: 10.1016/j.medengphy.2023.104006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 06/02/2023] [Accepted: 06/08/2023] [Indexed: 06/14/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA