1
|
Grimaudo V, Lopez DM, Prone G, Lüthi T, Flisch A, López AC, Grozovski V, Tulej M, Riedo A, Zboray R, Lörtscher E, Broekmann P, Wurz P. Quantitative laser-matter interaction: a 3D study of UV-fs-laser ablation on single crystalline Ru(0001). OPTICS EXPRESS 2023; 31:17964-17986. [PMID: 37381517 DOI: 10.1364/oe.485713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Accepted: 04/28/2023] [Indexed: 06/30/2023]
Abstract
Laser ablation is nowadays an extensively applied technology to probe the chemical composition of solid materials. It allows for precise targeting of micrometer objects on and in samples, and enables chemical depth profiling with nanometer resolution. An in-depth understanding of the 3D geometry of the ablation craters is crucial for precise calibration of the depth scale in chemical depth profiles. Herein we present a comprehensive study on laser ablation processes using a Gaussian-shaped UV-femtosecond irradiation source and present how the combination of three different imaging methods (scanning electron microscopy, interferometric microscopy, and X-ray computed tomography) can provide accurate information on the crater's shapes. Crater analysis by applying X-ray computed tomography is of considerable interest because it allows the imaging of an array of craters in one step with sub-µm accuracy and is not limited to the aspect ratio of the crater. X-ray computed tomography thereby complements the analysis of laser ablation craters. The study investigates the effect of laser pulse energy and laser burst count on a single crystal Ru(0001) sample. Single crystals ensure that there is no dependence on the grain orientations during the laser ablation process. An array of 156 craters of different dimensions ranging from <20 nm to ∼40 µm in depth were created. For each individually applied laser pulse, we measured the number of ions generated in the ablation plume with our laser ablation ionization mass spectrometer. We show to which extent the combination of these four techniques reveals valuable information on the ablation threshold, the ablation rate, and the limiting ablation depth. The latter is expected to be a consequence of decreasing irradiance upon increasing crater surface area. The ion signal generated was found to be proportional to the volume ablated up to the certain depth, which enables in-situ depth calibration during the measurement.
Collapse
|
2
|
Towards In-Situ Geochemical Analysis of Planetary Rocks and Soils by Laser Ablation/Ionisation Time-of-Flight Mass Spectrometry. UNIVERSE 2022. [DOI: 10.3390/universe8080410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Spectroscopic instruments were a part of payloads on orbiter and lander missions and delivered vast data sets to explore minerals, elements and molecules on air-less rocky planets, asteroids and comets on global and local scales. To answer current space science questions, the chemical composition of planetary rocks and soils at grain scale is required, as well as measurements of element (isotope) concentrations down to the part per million or lower. Only mass spectrometric methods equipped with laser sampling ion sources can deliver the necessary information. Laser sampling techniques can reduce the dimensions of the investigated sample material down to micrometre scale, allowing for the composition analysis of grain-sized objects or thin mineral layers with sufficiently high spatial resolution, such that important geological processes can be recognised and studied as they progressed in time. We describe the performance characteristics, when applied to meteorite and geological samples, of a miniaturised laser ablation/ionisation mass spectrometer (named LMS) system that has been developed in our group. The main advantages of the LMS instrument over competing techniques are illustrated by examples of high spatial (lateral and vertical) resolution studies in different meteorites, terrestrial minerals and fossil-like structures in ancient rocks for most elements of geochemical interest. Top-level parameters, such as dimension, weight, and power consumption of a possible flight design of the LMS system are presented as well.
Collapse
|
3
|
Instrumentation for Detecting Sulphur Isotopes as Biosignatures on Europa and Ganymede by Forthcoming Missions. UNIVERSE 2022. [DOI: 10.3390/universe8070357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
Abstract
There has been remarkable progress in identifying a certain type of biosignature, both from the point of view of the payloads of forthcoming missions, and from the point of view of biogeochemistry. This progress has been due to the evolution of miniaturized mass spectrometry that can be used, under certain circumstances and for certain samples, to distinguish between putatively abiotic and biotic sulphur isotopes. These specific types of biosignatures are discussed in the context of Europa and Ganymede. Such instruments are sufficiently precise to differentiate between abiotic and biotic signatures. We reflect on new possibilities that will be available during this decade for exploring the nearest ocean worlds: Europa and Ganymede. We review arguments that point out the presence of intriguing sulphur patches on Europa’s icy surface that were discovered by the Galileo mission. These patches lead to a “sulphur dilemma”, which suggests not to focus future measurements exclusively on organics. We comment on the possibility of measurements of sulphur isotopes, as one kind of biosignature, to be complemented with additional biosignatures, in order to fully test biogenicity. These suggestions are intended to point out the best use of the available spacecrafts’ payloads during the planning of the forthcoming Jovian missions.
Collapse
|
4
|
Lukmanov RA, Tulej M, Wiesendanger R, Riedo A, Grimaudo V, Ligterink NFW, de Koning C, Neubeck A, Wacey D, Wurz P. Multiwavelength Ablation/Ionization and Mass Spectrometric Analysis of 1.88 Ga Gunflint Chert. ASTROBIOLOGY 2022; 22:369-386. [PMID: 35196459 DOI: 10.1089/ast.2019.2201] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The investigation of chemical composition on planetary bodies without significant sample processing is of importance for nearly every mission aimed at robotic exploration. Moreover, it is a necessary tool to achieve the longstanding goal of finding evidence of life beyond Earth, for example, possibly preserved microbial remains within martian sediments. Our Laser Ablation Ionization Mass Spectrometer (LIMS) is a compact time-of-flight mass spectrometer intended to investigate the elemental, isotope, and molecular composition of a wide range of solid samples, including e.g., low bulk density organic remains in microfossils. Here, we present an overview of the instrument and collected chemical spectrometric data at the micrometer level from a Precambrian chert sample (1.88 Ga Gunflint Formation, Ontario, Canada), which is considered to be a martian analogue. Data were collected from two distinct zones-a silicified host area and a carbon-bearing microfossil assemblage zone. We performed these measurements using an ultrafast pulsed laser system (pulse width of ∼180 fs) with multiple wavelengths (infrared [IR]-775 nm, ultraviolet [UV]-387 nm, UV-258 nm) and using a pulsed high voltage on the mass spectrometer to reveal small organic signals. We investigated (1) the chemical composition of the sample and (2) the different laser wavelengths' performance to provide chemical depth profiles in silicified media. Our key findings are as follows: (1) microfossils from the Gunflint chert reveal a distinct chemical composition compared with the host mineralogy (we report the identification of 24 elements in the microfossils); (2) detection of the pristine composition of microfossils and co-occurring fine chemistry (rare earth elements) requires utilization of the depth profiling measurement protocol; and (3) our results show that, for analysis of heterogeneous material from siliciclastic deposits, siliceous sinters, and cherts, the most suitable wavelength for laser ablation/Ionization is UV-258 nm.
Collapse
Affiliation(s)
- Rustam A Lukmanov
- Space Research & Planetary Sciences (WP), Physics Institute, University of Bern, Bern, Switzerland
| | - Marek Tulej
- Space Research & Planetary Sciences (WP), Physics Institute, University of Bern, Bern, Switzerland
| | - Reto Wiesendanger
- Space Research & Planetary Sciences (WP), Physics Institute, University of Bern, Bern, Switzerland
| | - Andreas Riedo
- Space Research & Planetary Sciences (WP), Physics Institute, University of Bern, Bern, Switzerland
| | - Valentine Grimaudo
- Space Research & Planetary Sciences (WP), Physics Institute, University of Bern, Bern, Switzerland
| | - Niels F W Ligterink
- Space Research & Planetary Sciences (WP), Physics Institute, University of Bern, Bern, Switzerland
| | - Coenraad de Koning
- Space Research & Planetary Sciences (WP), Physics Institute, University of Bern, Bern, Switzerland
| | - Anna Neubeck
- Department of Earth Sciences, Uppsala University, Uppsala, Sweden
| | - David Wacey
- Centre for Microscopy, Characterization and Analysis, The University of Western Australia, Perth, Australia
| | - Peter Wurz
- Space Research & Planetary Sciences (WP), Physics Institute, University of Bern, Bern, Switzerland
| |
Collapse
|
5
|
Azov VA, Mueller L, Makarov AA. LASER IONIZATION MASS SPECTROMETRY AT 55: QUO VADIS? MASS SPECTROMETRY REVIEWS 2022; 41:100-151. [PMID: 33169900 DOI: 10.1002/mas.21669] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 10/09/2020] [Accepted: 10/12/2020] [Indexed: 06/11/2023]
Abstract
Laser ionization mass spectrometry (LIMS) was one of the first practical methods developed for in situ analysis of the surfaces of solid samples. This review will encompass several aspects related to this analytical method. First, we will discuss the process of laser ionization, the influence of the laser type on its performance, and imaging capabilities of this method. In the second chapter, we will follow the historic development of LIMS instrumentation. After a brief overview of the first-generation instruments developed in 1960-1990 years, we will discuss in detail more recent designs, which appeared during the last 2-3 decades. In the last part of our review, we will cover the recent applications of LIMS for surface analysis. These applications include various types of analyses of solid inorganic, organic, and heterogeneous samples, often in combination with depth profiling and imaging capability.
Collapse
Affiliation(s)
- Vladimir A Azov
- Department of Chemistry, University of the Free State, Bloemfontein, South Africa
| | | | - Alexander A Makarov
- Thermo Fisher Scientific GmbH, Bremen, Germany
- Biomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
6
|
Lukmanov RA, Riedo A, Wacey D, Ligterink NFW, Grimaudo V, Tulej M, de Koning C, Neubeck A, Wurz P. On Topological Analysis of fs-LIMS Data. Implications for in Situ Planetary Mass Spectrometry. Front Artif Intell 2021; 4:668163. [PMID: 34497998 PMCID: PMC8419467 DOI: 10.3389/frai.2021.668163] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Accepted: 08/05/2021] [Indexed: 11/17/2022] Open
Abstract
In this contribution, we present results of non-linear dimensionality reduction and classification of the fs laser ablation ionization mass spectrometry (LIMS) imaging dataset acquired from the Precambrian Gunflint chert (1.88 Ga) using a miniature time-of-flight mass spectrometer developed for in situ space applications. We discuss the data generation, processing, and analysis pipeline for the classification of the recorded fs-LIMS mass spectra. Further, we define topological biosignatures identified for Precambrian Gunflint microfossils by projecting the recorded fs-LIMS intensity space into low dimensions. Two distinct subtypes of microfossil-related spectra, a layer of organic contamination and inorganic quartz matrix were identified using the fs-LIMS data. The topological analysis applied to the fs-LIMS data allows to gain additional knowledge from large datasets, formulate hypotheses and quickly generate insights from spectral data. Our contribution illustrates the utility of applying spatially resolved mass spectrometry in combination with topology-based analytics in detecting signatures of early (primitive) life. Our results indicate that fs-LIMS, in combination with topological methods, provides a powerful analytical framework and could be applied to the study of other complex mineralogical samples.
Collapse
Affiliation(s)
- Rustam A Lukmanov
- Space Research and Planetary Sciences (WP), University of Bern, Bern, Switzerland
| | - Andreas Riedo
- Space Research and Planetary Sciences (WP), University of Bern, Bern, Switzerland
| | - David Wacey
- Centre for Microscopy, Characterisation and Analysis, The University of Western Australia, Perth, WA, Australia
| | - Niels F W Ligterink
- Space Research and Planetary Sciences (WP), University of Bern, Bern, Switzerland
| | - Valentine Grimaudo
- Space Research and Planetary Sciences (WP), University of Bern, Bern, Switzerland
| | - Marek Tulej
- Space Research and Planetary Sciences (WP), University of Bern, Bern, Switzerland
| | - Coenraad de Koning
- Space Research and Planetary Sciences (WP), University of Bern, Bern, Switzerland
| | - Anna Neubeck
- Department of Earth Sciences, Uppsala University, Uppsala, Sweden
| | - Peter Wurz
- Space Research and Planetary Sciences (WP), University of Bern, Bern, Switzerland
| |
Collapse
|
7
|
Riedo A, Lukmanov R, Grimaudo V, de Koning C, Ligterink NFW, Tulej M, Wurz P. Improved plasma stoichiometry recorded by laser ablation ionization mass spectrometry using a double-pulse femtosecond laser ablation ion source. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9094. [PMID: 33821534 DOI: 10.1002/rcm.9094] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 03/01/2021] [Accepted: 03/23/2021] [Indexed: 06/12/2023]
Abstract
RATIONALE Femtosecond (fs) laser ablation ion sources have allowed for improved measurement capabilities and figures of merit of laser ablation based spectroscopic and mass spectrometric measurement techniques. However, in comparison to longer pulse laser systems, the ablation plume from fs lasers is observed to be colder, which favors the formation of polyatomic species. Such species can limit the analytical capabilities of a system due to isobaric interferences. In this contribution, a double-pulse femtosecond (DP-fs) laser ablation ion source is coupled to our miniature Laser Ablation Ionization Mass Spectrometry (LIMS) system and its impact on the recorded stoichiometry of the generated plasma is analyzed in detail. METHODS A DP-fs laser ablation ion source (temporal delays of +300 to - 300 ps between pulses) is connected to our miniature LIMS system. The first pulse is used for material removal from the sample surface and the second for post-ionization of the ablation plume. To characterize the performance, parametric double- and single-pulse studies (temporal delays, variation of the pulse energy, voltage applied on detector system) were conducted on three different NIST SRM alloy samples (SRM 661, 664 and 665). RESULTS At optimal instrument settings for both the double-pulse laser ablation ion source and the detector voltage, relative sensitivity coefficients were observed to be closer (factor of ~2) to 1 compared with single-pulse measurements. Furthermore, the optimized settings worked for all three samples, meaning no further optimization was necessary when changing to another alloy sample material during this study. CONCLUSIONS The application of a double-pulse femtosecond laser ablation ion source resulted in the recording of improved stoichiometry of the generated plasma using our LIMS measurement technique. This is of great importance for the quantitative chemical analysis of more complex solid materials, e.g., geological samples or metal alloys, especially when aiming for standard-free quantification procedures for the determination of the chemical composition.
Collapse
Affiliation(s)
- Andreas Riedo
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, Bern, 3012, Switzerland
| | - Rustam Lukmanov
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, Bern, 3012, Switzerland
| | - Valentine Grimaudo
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, Bern, 3012, Switzerland
| | - Coenraad de Koning
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, Bern, 3012, Switzerland
| | - Niels F W Ligterink
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, Bern, 3012, Switzerland
| | - Marek Tulej
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, Bern, 3012, Switzerland
| | - Peter Wurz
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, Bern, 3012, Switzerland
| |
Collapse
|
8
|
Current Progress in Femtosecond Laser Ablation/Ionisation Time-of-Flight Mass Spectrometry. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11062562] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The last decade witnessed considerable progress in the development of laser ablation/ionisation time-of-flight mass spectrometry (LI-TOFMS). The improvement of both the laser ablation ion sources employing femtosecond lasers and the method of ion coupling with the mass analyser led to highly sensitive element and isotope measurements, minimisation of matrix effects, and reduction of various fractionation effects. This improvement of instrumental performance can be attributed to the progress in laser technology and accompanying commercialisation of fs-laser systems, as well as the availability of fast electronics and data acquisition systems. Application of femtosecond laser radiation to ablate the sample causes negligible thermal effects, which in turn allows for improved resolution of chemical surface imaging and depth profiling. Following in the footsteps of its predecessor ns-LIMS, fs-LIMS, which employs fs-laser ablation ion sources, has been developed in the last two decades as an important method of chemical analysis and will continue to improve its performance in subsequent decades. This review discusses the background of fs-laser ablation, overviews the most relevant instrumentation and emphasises their performance figures, and summarizes the studies on several applications, including geochemical, semiconductor, and bio-relevant materials. Improving the chemical analysis is expected by the implementation of laser pulse sequences or pulse shaping methods and shorter laser wavelengths providing current progress in mass resolution achieved in fs-LIMS. In parallel, advancing the methods of data analysis has the potential of making this technique very attractive for 3D chemical analysis with micrometre lateral and sub-micrometre vertical resolution.
Collapse
|
9
|
Tulej M, Neubeck A, Riedo A, Lukmanov R, Grimaudo V, Ligterink NFW, Ivarsson M, Bach W, de Koning C, Wurz P. Isotope abundance ratio measurements using femtosecond laser ablation ionization mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4660. [PMID: 33006261 DOI: 10.1002/jms.4660] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 09/07/2020] [Accepted: 09/15/2020] [Indexed: 06/11/2023]
Abstract
Accurate isotope ratio measurements are of high importance in various scientific fields, ranging from radio isotope geochronology of solids to studies of element isotopes fractionated by living organisms. Instrument limitations, such as unresolved isobaric inferences in the mass spectra, or cosampling of the material of interest together with the matrix material may reduce the quality of isotope measurements. Here, we describe a method for accurate isotope ratio measurements using our laser ablation ionization time-of-flight mass spectrometer (LIMS) that is designed for in situ planetary research. The method is based on chemical depth profiling that allows for identifying micrometer scale inclusions embedded in surrounding rocks with different composition inside the bulk of the sample. The data used for precise isotope measurements are improved using a spectrum cleaning procedure that ensures removal of low quality spectra. Furthermore, correlation of isotopes of an element is used to identify and reject the data points that, for example, do not belong to the species of interest. The measurements were conducted using IR femtosecond laser irradiation focused on the sample surface to a spot size of ~12 μm. Material removal was conducted for a predefined number of laser shots, and time-of-flight mass spectra were recorded for each of the ablated layers. Measurements were conducted on NIST SRM 986 Ni isotope standard, trevorite mineral, and micrometer-sized inclusions embedded in aragonite. Our measurements demonstrate that element isotope ratios can be measured with accuracies and precision at the permille level, exemplified by the analysis of B, Mg, and Ni element isotopes. The method applied will be used for in situ investigation of samples on planetary surfaces, for accurate quantification of element fractionation induced by, for example, past or present life or by geochemical processes.
Collapse
Affiliation(s)
- Marek Tulej
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Bern, Switzerland
| | - Anna Neubeck
- Department of Geological Sciences, Uppsala University, Uppsala, Sweden
| | - Andreas Riedo
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Bern, Switzerland
| | - Rustam Lukmanov
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Bern, Switzerland
| | - Valentine Grimaudo
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Bern, Switzerland
| | | | - Magnus Ivarsson
- Department of Biology, University of Southern Denmark, Odense, Denmark
- Department of Paleobiology, Swedish Museum of Natural History, Stockholm, Sweden
| | - Wolfgang Bach
- Department of Geosciences, University of Bremen, Bremen, Germany
| | - Coenraad de Koning
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Bern, Switzerland
| | - Peter Wurz
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Bern, Switzerland
| |
Collapse
|
10
|
Riedo A, de Koning C, Stevens AH, Cockell CS, McDonald A, López AC, Grimaudo V, Tulej M, Wurz P, Ehrenfreund P. The Detection of Elemental Signatures of Microbes in Martian Mudstone Analogs Using High Spatial Resolution Laser Ablation Ionization Mass Spectrometry. ASTROBIOLOGY 2020; 20:1224-1235. [PMID: 33001758 DOI: 10.1089/ast.2019.2087] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The detection and identification of biosignatures on planetary bodies such as Mars in situ is extremely challenging. Current knowledge from space exploration missions suggests that a suite of complementary instruments is required in situ for a successful identification of past or present life. For future exploration missions, new and innovative instrumentation capable of high spatial resolution chemical (elemental and isotope) analysis of solids with improved measurement capabilities is of considerable interest because a multitude of potential signatures of extinct or extant life have dimensions on the micrometer scale. The aim of this study is to extend the current measurement capabilities of a miniature laser ablation ionization mass spectrometer (LIMS) designed for space exploration missions to detect signatures of microbial life. In total, 14 martian mudstone analogue samples were investigated regarding their elemental composition. Half the samples were artificially inoculated with a low number density of microbes, and half were used as abiotic controls. The samples were treated in a number of ways. Some were cultured anaerobically and some aerobically; some abiotic samples were incubated with water, and some remained dry. Some of the samples were exposed to a large dose of γ radiation, and some were left un-irradiated. While no significant elemental differences were observed between the applied sample treatments, the instrument showed the capability to detect biogenic element signatures of the inoculated microbes by monitoring biologically relevant elements, such as hydrogen, carbon, sulfur, iron, and so on. When an enrichment in carbon was measured in the samples but no simultaneous increase in other biologically relevant elements was detected, it suggests, for example, a carbon-containing inclusion; when the enrichment was in carbon and in bio-relevant elements, it suggests the presences of microbes. This study presents first results on the detection of biogenic element patterns of microbial life using a miniature LIMS system designed for space exploration missions.
Collapse
Affiliation(s)
- Andreas Riedo
- Laboratory for Astrophysics, Leiden Observatory, Leiden University, Leiden, The Netherlands
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Coen de Koning
- Laboratory for Astrophysics, Leiden Observatory, Leiden University, Leiden, The Netherlands
| | - Adam H Stevens
- School of Physics and Astronomy, UK Centre for Astrobiology, University of Edinburgh, Edinburgh, United Kingdom
| | - Charles S Cockell
- School of Physics and Astronomy, UK Centre for Astrobiology, University of Edinburgh, Edinburgh, United Kingdom
| | - Alison McDonald
- School of Engineering, Bioimaging Facility, University of Edinburgh, Edinburgh, United Kingdom
| | - Alena Cedeño López
- Department of Chemistry and Biochemistry, University of Bern, Bern, Switzerland
| | - Valentine Grimaudo
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Marek Tulej
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Peter Wurz
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Pascale Ehrenfreund
- Laboratory for Astrophysics, Leiden Observatory, Leiden University, Leiden, The Netherlands
- Space Policy Institute, George Washington University, Washington, DC, USA
| |
Collapse
|
11
|
Grimaudo V, Tulej M, Riedo A, Lukmanov R, Ligterink NFW, de Koning C, Wurz P. UV post-ionization laser ablation ionization mass spectrometry for improved nm-depth profiling resolution on Cr/Ni reference standard. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8803. [PMID: 32246868 DOI: 10.1002/rcm.8803] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 03/30/2020] [Accepted: 03/30/2020] [Indexed: 06/11/2023]
Abstract
RATIONALE Laser ablation combined with mass spectrometry forms a promising tool for chemical depth profiling of solids. At irradiations near the ablation threshold, high depth resolutions are achieved. However, at these conditions, a large fraction of ablated species is neutral and therefore invisible to the instrument. To compensate for this effect, an additional ionization step can be introduced. METHODS Double-pulse laser ablation is frequently used in material sciences to produce shallow craters. We apply double-pulse UV femtosecond (fs) Laser Ablation Ionization Mass Spectrometry to investigate the depth profiling performance. The first pulse energy is set to gentle ablation conditions, whereas the second pulse is applied at a delay and a pulse energy promoting the highest possible ion yield. RESULTS The experiments were performed on a Cr/Ni multi-layered standard. For a mean ablation rate of ~3 nm/pulse (~72 nJ/pulse), a delay of ~73 ps provided optimal results. By further increasing the energy of the second pulse (5-30% higher with respect to the first pulse) an enhancement of up to 15 times the single pulse intensity was achieved. These conditions resulted in mean depth resolutions of ~37 and ~30 nm for the Cr and Ni layers, respectively. CONCLUSIONS It is demonstrated on the thin-film standard that the double-pulse excitation scheme substantially enhances the chemical depth profiling resolution of LIMS with respect to the single-pulse scheme. The post-ionization allows for extraordinarily low ablation rates and for quantitative and stoichiometric analysis of nm-thick films/coatings.
Collapse
Affiliation(s)
- Valentine Grimaudo
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Switzerland
| | - Marek Tulej
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Switzerland
| | - Andreas Riedo
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Switzerland
| | - Rustam Lukmanov
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Switzerland
| | | | - Coenraad de Koning
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Switzerland
| | - Peter Wurz
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Switzerland
| |
Collapse
|
12
|
Ligterink NFW, Grimaudo V, Moreno-García P, Lukmanov R, Tulej M, Leya I, Lindner R, Wurz P, Cockell CS, Ehrenfreund P, Riedo A. ORIGIN: a novel and compact Laser Desorption - Mass Spectrometry system for sensitive in situ detection of amino acids on extraterrestrial surfaces. Sci Rep 2020; 10:9641. [PMID: 32541786 PMCID: PMC7296031 DOI: 10.1038/s41598-020-66240-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 05/14/2020] [Indexed: 11/17/2022] Open
Abstract
For the last four decades space exploration missions have searched for molecular life on planetary surfaces beyond Earth. Often pyrolysis gas chromatography mass spectrometry has been used as payload on such space exploration missions. These instruments have relatively low detection sensitivity and their measurements are often undermined by the presence of chloride salts and minerals. Currently, ocean worlds in the outer Solar System, such as the icy moons Europa and Enceladus, represent potentially habitable environments and are therefore prime targets for the search for biosignatures. For future space exploration missions, novel measurement concepts, capable of detecting low concentrations of biomolecules with significantly improved sensitivity and specificity are required. Here we report on a novel analytical technique for the detection of extremely low concentrations of amino acids using ORIGIN, a compact and lightweight laser desorption ionization - mass spectrometer designed and developed for in situ space exploration missions. The identified unique mass fragmentation patterns of amino acids coupled to a multi-position laser scan, allows for a robust identification and quantification of amino acids. With a detection limit of a few fmol mm-2, and the possibility for sub-fmol detection sensitivity, this measurement technique excels current space exploration systems by three orders of magnitude. Moreover, our detection method is not affected by chemical alterations through surface minerals and/or salts, such as NaCl that is expected to be present at the percent level on ocean worlds. Our results demonstrate that ORIGIN is a promising instrument for the detection of signatures of life and ready for upcoming space missions, such as the Europa Lander.
Collapse
Affiliation(s)
| | - Valentine Grimaudo
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Pavel Moreno-García
- Interfacial Electrochemistry Group, Department of Chemistry and Biochemistry, University of Bern, Bern, Switzerland
| | - Rustam Lukmanov
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Marek Tulej
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Ingo Leya
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Robert Lindner
- Life Support and Physical Sciences Instrumentation Section, European Space Agency, ESTEC, Bern, The Netherlands
| | - Peter Wurz
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Charles S Cockell
- School of Physics and Astronomy, UK Centre for Astrobiology, University of Edinburgh, Edinburgh, United Kingdom
| | - Pascale Ehrenfreund
- Laboratory for Astrophysics, Leiden Observatory, Leiden University, Leiden, The Netherlands
- Space Policy Institute, George Washington University, 20052, Washington, DC, USA
| | - Andreas Riedo
- Laboratory for Astrophysics, Leiden Observatory, Leiden University, Leiden, The Netherlands
| |
Collapse
|
13
|
Stevens AH, McDonald A, de Koning C, Riedo A, Preston LJ, Ehrenfreund P, Wurz P, Cockell CS. Detectability of biosignatures in a low-biomass simulation of martian sediments. Sci Rep 2019; 9:9706. [PMID: 31273294 PMCID: PMC6609699 DOI: 10.1038/s41598-019-46239-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Accepted: 06/18/2019] [Indexed: 01/19/2023] Open
Abstract
Discovery of a remnant habitable environment by the Mars Science Laboratory in the sedimentary record of Gale Crater has reinvigorated the search for evidence of martian life. In this study, we used a simulated martian mudstone material, based on data from Gale Crater, that was inoculated and cultured over several months and then dried and pressed. The simulated mudstone was analysed with a range of techniques to investigate the detectability of biosignatures. Cell counting and DNA extraction showed a diverse but low biomass microbial community that was highly dispersed. Pellets were analysed with bulk Elemental Analysis – Isotope Ratio Mass Spectrometry (EA-IRMS), high-resolution Laser-ablation Ionisation Mass Spectrometry (LIMS), Raman spectroscopy and Fourier Transform InfraRed (FTIR) spectroscopy, which are all techniques of relevance to current and future space missions. Bulk analytical techniques were unable to differentiate between inoculated samples and abiotic controls, despite total levels of organic carbon comparable with that of the martian surface. Raman spectroscopy, FTIR spectroscopy and LIMS, which are high sensitivity techniques that provide chemical information at high spatial resolution, retrieved presumptive biosignatures but these remained ambiguous and the sedimentary matrix presented challenges for all techniques. This suggests challenges for detecting definitive evidence for life, both in the simulated lacustrine environment via standard microbiological techniques and in the simulated mudstone via analytical techniques with relevance to robotic missions. Our study suggests that multiple co-incident high-sensitivity techniques that can scan the same micrometre-scale spots are required to unambiguously detect biosignatures, but the spatial coverage of these techniques needs to be high enough not to miss individual cellular-scale structures in the matrix.
Collapse
Affiliation(s)
- Adam H Stevens
- UK Centre for Astrobiology, School of Physics and Astronomy, University of Edinburgh, Edinburgh, UK.
| | - Alison McDonald
- School of Engineering, Bioimaging Facility, University of Edinburgh, Edinburgh, UK
| | - Coen de Koning
- Sackler Laboratory for Astrophysics, Leiden Observatory, Leiden University, Leiden, The Netherlands
| | - Andreas Riedo
- Sackler Laboratory for Astrophysics, Leiden Observatory, Leiden University, Leiden, The Netherlands.,Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Louisa J Preston
- Dept. of Earth and Planetary Sciences, Birkbeck, University of London, London, UK
| | - Pascale Ehrenfreund
- Sackler Laboratory for Astrophysics, Leiden Observatory, Leiden University, Leiden, The Netherlands
| | - Peter Wurz
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Charles S Cockell
- UK Centre for Astrobiology, School of Physics and Astronomy, University of Edinburgh, Edinburgh, UK
| |
Collapse
|
14
|
Wiesendanger R, Wacey D, Tulej M, Neubeck A, Ivarsson M, Grimaudo V, Moreno-García P, Cedeño-López A, Riedo A, Wurz P. Chemical and Optical Identification of Micrometer-Sized 1.9 Billion-Year-Old Fossils by Combining a Miniature Laser Ablation Ionization Mass Spectrometry System with an Optical Microscope. ASTROBIOLOGY 2018; 18:1071-1080. [PMID: 30095994 DOI: 10.1089/ast.2017.1780] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The recognition of biosignatures on planetary bodies requires the analysis of the putative microfossil with a set of complementary analytical techniques. This includes localized elemental and isotopic analysis of both, the putative microfossil and its surrounding host matrix. If the analysis can be performed with spatial resolution at the micrometer level and ppm detection sensitivities, valuable information on the (bio)chemical and physical processes that influenced the sample material can be gained. Our miniaturized laser ablation ionization mass spectrometry (LIMS)-time-of-flight mass spectrometer instrument is a valid candidate for performing the required chemical analysis in situ. However, up until now it was limited by the spatial accuracy of the sampling. In this contribution, we introduce a newly developed microscope system with micrometer accuracy for Ultra High Vacuum application, which allows a significant increase in the measurement capabilities of our miniature LIMS system. The new enhancement allows identification and efficient and accurate sampling of features of micrometer-sized fossils in a host matrix. The performance of our system is demonstrated by the identification and chemical analysis of signatures of micrometer-sized fossil structures in the 1.9 billion-year-old Gunflint chert.
Collapse
Affiliation(s)
- Reto Wiesendanger
- 1 Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
- 2 Microsystems for Space Technologies Laboratory, Ecole Polytechnique Fédérale, Lausanne, Neuchâtel, Switzerland
| | - David Wacey
- 3 Centre for Microscopy Characterisation and Analysis, The University of Western Australia, Perth, Australia
| | - Marek Tulej
- 1 Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| | - Anna Neubeck
- 4 Department of Geological Sciences, Stockholm University, Stockholm, Sweden
| | - Magnus Ivarsson
- 5 Department of Paleobiology, Nordic Centre for Earth Evolution, Swedish Museum of Natural History, Stockholm, Sweden
- 6 Department of Biology, University of Southern Denmark, Odense, Denmark
| | - Valentine Grimaudo
- 7 Department of Chemistry and Biochemistry, Interfacial Electrochemistry Group, University of Bern , Bern, Switzerland
| | - Pavel Moreno-García
- 7 Department of Chemistry and Biochemistry, Interfacial Electrochemistry Group, University of Bern , Bern, Switzerland
| | - Alena Cedeño-López
- 7 Department of Chemistry and Biochemistry, Interfacial Electrochemistry Group, University of Bern , Bern, Switzerland
| | - Andreas Riedo
- 8 Sackler Laboratory for Astrophysics, Leiden Observatory, Leiden University , The Netherlands
| | - Peter Wurz
- 1 Space Research and Planetary Sciences, Physics Institute, University of Bern, Bern, Switzerland
| |
Collapse
|
15
|
Grimaudo V, Moreno-García P, Cedeño López A, Riedo A, Wiesendanger R, Tulej M, Gruber C, Lörtscher E, Wurz P, Broekmann P. Depth Profiling and Cross-Sectional Laser Ablation Ionization Mass Spectrometry Studies of Through-Silicon-Vias. Anal Chem 2018; 90:5179-5186. [DOI: 10.1021/acs.analchem.7b05313] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Affiliation(s)
- Valentine Grimaudo
- Department of Chemistry and Biochemistry, University of Bern, Freiestrasse 3, 3012 Bern, Switzerland
| | - Pavel Moreno-García
- Department of Chemistry and Biochemistry, University of Bern, Freiestrasse 3, 3012 Bern, Switzerland
| | - Alena Cedeño López
- Department of Chemistry and Biochemistry, University of Bern, Freiestrasse 3, 3012 Bern, Switzerland
| | - Andreas Riedo
- Sackler Laboratory for Astrophysics, Leiden University, Niels Bohrweg 2, 2333 CA Leiden, The Netherlands
| | - Reto Wiesendanger
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland
| | - Marek Tulej
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland
| | - Cynthia Gruber
- IBM Research - Zürich, Science and Technology Department, Säumerstrasse 4, 8803 Rüschlikon, Switzerland
| | - Emanuel Lörtscher
- IBM Research - Zürich, Science and Technology Department, Säumerstrasse 4, 8803 Rüschlikon, Switzerland
| | - Peter Wurz
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland
| | - Peter Broekmann
- Department of Chemistry and Biochemistry, University of Bern, Freiestrasse 3, 3012 Bern, Switzerland
| |
Collapse
|
16
|
Combining Anisotropic Etching and PDMS Casting for Three-Dimensional Analysis of Laser Ablation Processes. Anal Chem 2018; 90:2692-2700. [DOI: 10.1021/acs.analchem.7b04539] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
17
|
Chela-Flores J. Instrumentation for Testing Whether the Icy Moons of the Gas and Ice Giants Are Inhabited. ASTROBIOLOGY 2017; 17:958-961. [PMID: 29019413 DOI: 10.1089/ast.2016.1621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Evidence of life beyond Earth may be closer than we think, given that the forthcoming missions to the jovian system will be equipped with instruments capable of probing Europa's icy surface for possible biosignatures, including chemical biomarkers, despite the strong radiation environment. Geochemical biomarkers may also exist beyond Europa on icy moons of the gas giants. Sulfur is proposed as a reliable geochemical biomarker for approved and forthcoming missions to the outer solar system. Key Words: JUICE mission-Clipper mission-Geochemical biomarkers-Europa-Moons of the ice giants-Geochemistry-Mass spectrometry. Astrobiology 17, 958-961.
Collapse
Affiliation(s)
- Julian Chela-Flores
- 1 The Abdus Salam International Centre for Theoretical Physics , Trieste, Italy
- 2 IDEA, Fundacion Instituto de Estudios Avanzados Caracas , República Bolivariana de Venezuela
| |
Collapse
|
18
|
Meyer S, Riedo A, Neuland MB, Tulej M, Wurz P. Fully automatic and precise data analysis developed for time-of-flight mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2017; 52:580-590. [PMID: 28666311 DOI: 10.1002/jms.3964] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Revised: 06/22/2017] [Accepted: 06/22/2017] [Indexed: 06/07/2023]
Abstract
Scientific objectives of current and future space missions are focused on the investigation of the origin and evolution of the solar system with the particular emphasis on habitability and signatures of past and present life. For in situ measurements of the chemical composition of solid samples on planetary surfaces, the neutral atmospheric gas and the thermal plasma of planetary atmospheres, the application of mass spectrometers making use of time-of-flight mass analysers is a technique widely used. However, such investigations imply measurements with good statistics and, thus, a large amount of data to be analysed. Therefore, faster and especially robust automated data analysis with enhanced accuracy is required. In this contribution, an automatic data analysis software, which allows fast and precise quantitative data analysis of time-of-flight mass spectrometric data, is presented and discussed in detail. A crucial part of this software is a robust and fast peak finding algorithm with a consecutive numerical integration method allowing precise data analysis. We tested our analysis software with data from different time-of-flight mass spectrometers and different measurement campaigns thereof. The quantitative analysis of isotopes, using automatic data analysis, yields results with an accuracy of isotope ratios up to 100 ppm for a signal-to-noise ratio (SNR) of 104 . We show that the accuracy of isotope ratios is in fact proportional to SNR-1 . Furthermore, we observe that the accuracy of isotope ratios is inversely proportional to the mass resolution. Additionally, we show that the accuracy of isotope ratios is depending on the sample width Ts by Ts0.5 . Copyright © 2017 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Stefan Meyer
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Sidlerstrasse 5, 3012, Bern, Switzerland
| | - Andreas Riedo
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Sidlerstrasse 5, 3012, Bern, Switzerland
- Sackler Laboratory for Astrophysics, Leiden Observatory, Leiden University, Niels Bohrweg 2, 2333 CA, Leiden, The Netherlands
| | - Maike B Neuland
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Sidlerstrasse 5, 3012, Bern, Switzerland
- Solar System Physics and Space Technology, Swedish Institute of Space Physics, IRF, Rymdcampus1, SE-981 28, Kiruna, Sweden
| | - Marek Tulej
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Sidlerstrasse 5, 3012, Bern, Switzerland
| | - Peter Wurz
- Space Research and Planetary Sciences, Physics Institute, University of Bern, Sidlerstrasse 5, 3012, Bern, Switzerland
| |
Collapse
|
19
|
Riedo A, Tulej M, Rohner U, Wurz P. High-speed microstrip multi-anode multichannel plate detector system. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2017; 88:045114. [PMID: 28456239 DOI: 10.1063/1.4981813] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
High-speed detector systems with high dynamic range and pulse width characteristics in the sub-nanosecond regime are mandatory for high resolution and highly sensitive time-of-flight mass spectrometers. Typically, for a reasonable detector area, an impedance-matched anode design is necessary to transmit the registered signal fast and distortion-free from the anode to the signal acquisition system. In this report, a high-speed microstrip multi-anode multichannel plate detector is presented and discussed. The anode consists of four separate active concentric anode segments allowing a simultaneous readout of signal with a dynamic range of about eight orders of magnitude. The impedance matched anode segments show pulse width of about 250 ps, measured at full width at half maximum, and rise time of ∼170 ps, measured with an oscilloscope with a sampling rate of 20 GS/s and 4 GHz analogue bandwidth. The usage of multichannel plates as signal amplifier allowed the design of a lightweight, low power consuming, and compact detector system, suitable, e.g., for the integration into space instrumentation or portable systems where size, weight, and power consumption are limited parameters.
Collapse
Affiliation(s)
- Andreas Riedo
- Leiden Observatory, Sackler Laboratory for Astrophysics, Leiden University, Leiden, The Netherlands
| | - Marek Tulej
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Bern, Switzerland
| | - Urs Rohner
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Bern, Switzerland
| | - Peter Wurz
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Bern, Switzerland
| |
Collapse
|