Nielsen CG, Grigonyte-Daraskeviciene M, Olsen MT, Møller MH, Nørgaard K, Perner A, Mårtensson J, Pedersen-Bjergaard U, Kristensen PL, Bestle MH. Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review. Intensive Care Med 2024; 50:2005-2018. [PMID: 39417874 DOI: 10.1007/s00134-024-07663-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2024] [Accepted: 09/14/2024] [Indexed: 10/19/2024]
Abstract
PURPOSE Glycemic control poses a challenge in intensive care unit (ICU) patients and dysglycemia is associated with poor outcomes. Continuous glucose monitoring (CGM) has been successfully implemented in the type 1 diabetes out-patient setting and renewed interest has been directed into the transition of CGM into the ICU. This scoping review aimed to provide an overview of CGM accuracy in ICU patients to inform future research and CGM implementation. METHODS We systematically searched PubMed and EMBASE between 5th of December 2023 and 21st of May 2024 and reported findings in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline for scoping reviews (PRISMA-ScR). We assessed studies reporting the accuracy of CGM in the ICU and report study characteristics and accuracy outcomes. RESULTS We identified 2133 studies, of which 96 were included. Most studies were observational (91.7%), conducted in adult patients (74%), in mixed ICUs (47.9%), from 2014 and onward, and assessed subcutaneous CGM systems (80%) using arterial blood samples as reference test (40.6%). Half of the studies (56.3%) mention the use of a prespecified reference test protocol. The mean absolute relative difference (MARD) ranged from 6.6 to 30.5% for all subcutaneous CGM studies. For newer factory calibrated CGM, MARD ranged from 9.7 to 20.6%. MARD for intravenous CGM was 5-14.2% and 6.4-13% for intraarterial CGM. CONCLUSIONS In this scoping review of CGM accuracy in the ICU, we found great diversity in accuracy reporting. Accuracy varied depending on CGM and comparator, and may be better for intravascular CGM and potentially lower during hypoglycemia.
Collapse
Affiliation(s)
- Christian G Nielsen
- Department of Anesthesiology and Intensive Care, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark.
| | | | - Mikkel T Olsen
- Department of Endocrinology and Nephrology, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
| | - Morten H Møller
- Department of Intensive Care, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Kirsten Nørgaard
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Clinical Translational Research, Steno Diabetes Center Copenhagen, Herlev, Denmark
| | - Anders Perner
- Department of Intensive Care, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Johan Mårtensson
- Department of Physiology and Pharmacology, Section of Anesthesia and Intensive Care, Karolinska Institutet, Stockholm, Sweden
- Department of Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden
| | - Ulrik Pedersen-Bjergaard
- Department of Endocrinology and Nephrology, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Peter L Kristensen
- Department of Endocrinology and Nephrology, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Morten H Bestle
- Department of Anesthesiology and Intensive Care, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
2
|
Bellido V, Freckman G, Pérez A, Galindo RJ. Accuracy and Potential Interferences of Continuous Glucose Monitoring Sensors in the Hospital. Endocr Pract 2023; 29:919-927. [PMID: 37369291 DOI: 10.1016/j.eprac.2023.06.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 06/15/2023] [Accepted: 06/19/2023] [Indexed: 06/29/2023]
Abstract
For years, the standard of care for monitoring dysglycemia in hospitalized patients was capillary blood glucose (CBG) testing with point-of-care glucose meters. Recently, there has been a revolution in novel factory-calibrated continuous glucose monitoring (CGM) systems. Newer CGMs are smaller and less expensive, have improved accuracy and longer wear time, and do not require fingerstick CBG for calibration, resulting in increased utilization in ambulatory settings. Consequently, hospitals have noticed increased usability of CGMs among hospitalized patients and expect a progressive continued increase. During the COVID-19 pandemic, there was a critical need for innovative approaches to glycemic monitoring, with several pilot implementation projects using CGM in the intensive care unit and non-intensive care unit settings, further boosting the evidence in this area. Hence, recent guidelines have provided recommendations for the use of CGM in specific hospital scenarios and highlighted the potential of CGM to overcome CBG limitations for glucose monitoring in the inpatient setting. In this review, we provide the following: 1) an up-to-date review of the accuracy of the newer CGMs in hospitalized patients, 2) a discussion of standards for CGM accuracy metrics, 3) a contemporary overview of potential interferences that may cause inaccuracies or poor CGM performance, and 4) required steps for full regulatory approval of CGMs in the hospital and future research steps to advance the field forward.
Collapse
Affiliation(s)
- Virginia Bellido
- Unidad de Gestión Clínica de Endocrinología y Nutrición, Hospital Universitario Virgen del Rocío, Sevilla, Spain, Instituto de Biomedicina de Sevilla (IBiS), Hospital Universitario Virgen del Rocío/CSIC/Universidad de Sevilla, Sevilla, Spain
| | - Guido Freckman
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Antonio Pérez
- Servicio de Endocrinología y Nutrición. Hospital de la Santa Creu i Sant Pau, IIB Sant Pau, Universitat Autònoma de Barcelona. CIBER de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Barcelona, España
| | - Rodolfo J Galindo
- University of Miami Miller School of Medicine, Division of Endocrinology, Diabetes and Metabolism, Miami, Florida.
| |
Collapse
|
3
|
DeJournett J, Nekludov M, DeJournett L, Wallin M. Performance of a closed-loop glucose control system, comprising a continuous glucose monitoring system and an AI-based controller in swine during severe hypo- and hyperglycemic provocations. J Clin Monit Comput 2020; 35:317-325. [PMID: 32006145 PMCID: PMC7943496 DOI: 10.1007/s10877-020-00474-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2019] [Accepted: 01/24/2020] [Indexed: 01/04/2023]
Abstract
Intensive care unit (ICU) patients develop stress induced insulin resistance causing hyperglycemia, large glucose variability and hypoglycemia. These glucose metrics have all been associated with increased rates of morbidity and mortality. The only way to achieve safe glucose control at a lower glucose range (e.g., 4.4–6.6 mmol/L) will be through use of an autonomous closed loop glucose control system (artificial pancreas). Our goal with the present study was to assess the safety and performance of an artificial pancreas system, composed of the EIRUS (Maquet Critical Care AB) continuous glucose monitor (CGM) and novel artificial intelligence-based glucose control software, in a swine model using unannounced hypo- and hyperglycemia challenges. Fourteen piglets (6 control, 8 treated) underwent sequential unannounced hypoglycemic and hyperglycemic challenges with 3 IU of NovoRapid and a glucose infusion at 17 mg/kg/min over the course of 5 h. In the Control animals an experienced ICU physician used every 30-min blood glucose values to maintain control to a range of 4.4–9 mmol/L. In the Treated group the artificial pancreas system attempted to maintain blood glucose control to a range of 4.4–6.6 mmol/L. Five of six Control animals and none of eight Treated animals experienced severe hypoglycemia (< 2.22 mmol/L). The area under the curve 3.5 mmol/L was 28.9 (21.1–54.2) for Control and 4.8 (3.1–5.2) for the Treated animals. The total percent time within tight glucose control range, 4.4–6.6 mmol/L, was 32.8% (32.4–47.1) for Controls and 55.4% (52.9–59.4) for Treated (p < 0.034). Data are median and quartiles. The artificial pancreas system abolished severe hypoglycemia and outperformed the experienced ICU physician in avoiding clinically significant hypoglycemic excursions.
Collapse
Affiliation(s)
- Jeremy DeJournett
- Ideal Medical Technologies, 18 N Kensington Rd, Asheville, NC 28804 USA
| | - Michael Nekludov
- Karolinska University Hospital, Karolinska Universitetssjukhuset, Eugeniavägen 3, 171 76 Solna, Sweden
| | - Leon DeJournett
- Ideal Medical Technologies, 18 N Kensington Rd, Asheville, NC 28804 USA
| | - Mats Wallin
- Maquet Critical Care AB, Röntgenvägen 2, 17154 Solna, Sweden
| |
Collapse
|
4
|
Abstract
OBJECTIVES Tight glycemic control using intermittent blood glucose measurements is associated with a risk of hypoglycemia. Glucose concentrations can now be measured near continuously (every 5-15 min). We assessed the quality and safety of glycemic control guided by a near-continuous glucose monitoring system in ICU patients. DESIGN Prospective, cluster-randomized, crossover study. SETTING Thirty-five-bed medico-surgical department of intensive care with four separate ICUs. PATIENTS Adult patients admitted to the department and expected to stay for at least 3 days were considered for inclusion if they had persistent hyperglycemia (blood glucose > 150 mg/dL) up to 6 hours after admission and/or were receiving insulin therapy. INTERVENTIONS A peripheral venous catheter was inserted in all patients and connected to a continuous glucose monitoring sensor (GlucoClear; Edwards Lifesciences, Irvine, CA). The four ICUs were randomized in pairs in a crossover design to glycemic control using unblinded or blinded continuous glucose monitoring monitors. The insulin infusion rate was adjusted to keep blood glucose between 90 and 150 mg/dL using the blood glucose values displayed on the continuous glucose monitor (continuous glucose monitoring group-unblinded units) or according to intermittent blood glucose readings (intermittent glucose monitoring group-blinded units). MEASUREMENTS AND MAIN RESULTS The quality and safety of glycemic control were assessed using the proportion of time in range, the frequency of blood glucose less than 70 mg/dL, and the time spent with blood glucose less than 70 mg/dL (TB70), using blood glucose values measured by the continuous glucose monitoring device. Seventy-seven patients were enrolled: 39 in the continuous glucose monitoring group and 38 in the intermittent glucose monitoring group. A total of 43,107 blood glucose values were recorded. The time in range was similar in the two groups. The incidence of hypoglycemia (8/39 [20.5%] vs 15/38 [39.5%]) and the TB70 (0.4% ± 0.9% vs 1.6% ± 3.4%; p < 0.05) was lower in the continuous glucose monitoring than in the intermittent glucose monitoring group. CONCLUSIONS Use of a continuous glucose monitoring-based strategy decreased the incidence and severity of hypoglycemia, thus improving the safety of glycemic control.
Collapse
|
5
|
Polderman JAW, Ma XL, Eshuis WJ, Hollmann MW, DeVries JH, Preckel B, Hermanides J. Efficacy of continuous intravenous glucose monitoring in perioperative glycaemic control: a randomized controlled study. Br J Anaesth 2018; 118:264-266. [PMID: 28100531 DOI: 10.1093/bja/aew455] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
6
|
Satyarengga M, Siddiqui T, Spanakis EK. Designing the Glucose Telemetry for Hospital Management: From Bedside to the Nursing Station. Curr Diab Rep 2018; 18:87. [PMID: 30159754 DOI: 10.1007/s11892-018-1067-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE OF THE REVIEW Hospitalized patients with diabetes are monitored with point-of-care glucose testing. Continuous glucose monitoring (CGM) devices represent an alternative way to monitor glucose values; however, the in-hospital CGM use is still considered experimental. Most inpatient studies used "blinded" CGM properties and only few used the real-time/unblinded CGM features. One major limitation of the CGM devices is that they need to be placed at the patients' bedside, limiting any therapeutic interventions. In this article, we review the real-time/unblinded CGM use and share our thoughts about the development of future inpatient CGM systems. RECENT FINDINGS We recently reported that glucose values can be wirelessly transmitted to the nursing station, providing remote continuous glucose monitoring. Future inpatient CGM devices may be utilized for patients at risk for hypoglycemia similarly to the way that we use cardiac telemetry to monitor hospitalized patients who are at increased risk for cardiac arrhythmias.
Collapse
Affiliation(s)
- Medha Satyarengga
- Division of Endocrinology, Diabetes, and Nutrition, University of Maryland School of Medicine, 827 Linden Avenue, Baltimore, MD, 21201, USA
| | - Tariq Siddiqui
- Division of Endocrinology, Diabetes, and Nutrition, University of Maryland School of Medicine, 827 Linden Avenue, Baltimore, MD, 21201, USA
- Division of Endocrinology, Baltimore Veterans Affairs Medical Center, 10 N. Greene Street, Baltimore, MD, 21201, USA
| | - Elias K Spanakis
- Division of Endocrinology, Diabetes, and Nutrition, University of Maryland School of Medicine, 827 Linden Avenue, Baltimore, MD, 21201, USA.
- Division of Endocrinology, Baltimore Veterans Affairs Medical Center, 10 N. Greene Street, Baltimore, MD, 21201, USA.
| |
Collapse
|
7
|
van Steen SCJ, Rijkenberg S, Limpens J, van der Voort PHJ, Hermanides J, DeVries JH. The Clinical Benefits and Accuracy of Continuous Glucose Monitoring Systems in Critically Ill Patients-A Systematic Scoping Review. SENSORS 2017; 17:s17010146. [PMID: 28098809 PMCID: PMC5298719 DOI: 10.3390/s17010146] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 12/15/2016] [Accepted: 01/08/2017] [Indexed: 12/18/2022]
Abstract
Continuous Glucose Monitoring (CGM) systems could improve glycemic control in critically ill patients. We aimed to identify the evidence on the clinical benefits and accuracy of CGM systems in these patients. For this, we performed a systematic search in Ovid MEDLINE, from inception to 26 July 2016. Outcomes were efficacy, accuracy, safety, workload and costs. Our search retrieved 356 articles, of which 37 were included. Randomized controlled trials on efficacy were scarce (n = 5) and show methodological limitations. CGM with automated insulin infusion improved time in target and mean glucose in one trial and two trials showed a decrease in hypoglycemic episodes and time in hypoglycemia. Thirty-two articles assessed accuracy, which was overall moderate to good, the latter mainly with intravascular devices. Accuracy in critically ill children seemed lower than in adults. Adverse events were rare. One study investigated the effect on workload and cost, and showed a significant reduction in both. In conclusion, studies on the efficacy and accuracy were heterogeneous and difficult to compare. There was no consistent clinical benefit in the small number of studies available. Overall accuracy was moderate to good with some intravascular devices. CGM systems seemed however safe, and might positively affect workload and costs.
Collapse
Affiliation(s)
- Sigrid C J van Steen
- Clinical Diabetology, Academic Medical Center, P.O. Box 22660, 1100 DD Amsterdam, The Netherlands.
| | - Saskia Rijkenberg
- Department of Intensive Care Medicine, Onze Lieve Vrouwe Gasthuis, P.O. Box 95500, 1090 HM Amsterdam, The Netherlands.
| | - Jacqueline Limpens
- Medical Library, Academic Medical Center, P.O. Box 22660, 1100 DD Amsterdam, The Netherlands.
| | - Peter H J van der Voort
- Department of Intensive Care Medicine, Onze Lieve Vrouwe Gasthuis, P.O. Box 95500, 1090 HM Amsterdam, The Netherlands.
| | - Jeroen Hermanides
- Department of Anesthesiology, Academic Medical Center, P.O. Box 22660, 1100 DD Amsterdam, The Netherlands.
| | - J Hans DeVries
- Clinical Diabetology, Academic Medical Center, P.O. Box 22660, 1100 DD Amsterdam, The Netherlands.
| |
Collapse
|
8
|
Soto RJ, Hall JR, Brown MD, Taylor JB, Schoenfisch MH. In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility. Anal Chem 2017; 89:276-299. [PMID: 28105839 PMCID: PMC6773264 DOI: 10.1021/acs.analchem.6b04251] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Robert J. Soto
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, NC 27599
| | - Jackson R. Hall
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, NC 27599
| | - Micah D. Brown
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, NC 27599
| | - James B. Taylor
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, NC 27599
| | - Mark H. Schoenfisch
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, NC 27599
| |
Collapse
|
9
|
Righy Shinotsuka C, Brasseur A, Fagnoul D, So T, Vincent JL, Preiser JC. Manual versus Automated moNitoring Accuracy of GlucosE II (MANAGE II). Crit Care 2016; 20:380. [PMID: 27884157 PMCID: PMC5123350 DOI: 10.1186/s13054-016-1547-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Accepted: 10/31/2016] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND Intravascular continuous glucose monitoring (CGM) may facilitate glycemic control in the intensive care unit (ICU). We compared the accuracy of a CGM device (OptiScanner®) with a standard reference method. METHODS Adult patients who had blood glucose (BG) levels >150 mg/dl and required insertion of an arterial and central venous catheter were included. The OptiScanner® was inserted into a multiple-lumen central venous catheter. Patients were treated using a dynamic-scale insulin algorithm to achieve BG values between 80 and 150 mg/dl. The BG values measured by the OptiScanner® were plotted against BG values measured using a reference analyzer. The correlation between the BG values measured using the two methods and the clinical relevance of any differences were assessed using the coefficient of determination (r 2) and the Clarke error grid, respectively; bias was assessed by the mean absolute relative difference (MARD). Three different standards of glucose monitoring were used to assess accuracy. Glycemic control was assessed using the time in range (TIR). Six indices of glycemic variability were calculated. RESULTS The analysis included 929 paired samples from 88 patients, monitored for a total of 2584 hours. Reference BG values ranged between 60 and 484 mg/dl. The r 2 value was 0.89. The percentage of BG values within zones A and B of the Clarke error grid was 99.9%; the MARD was 7.7%. Using the ISO 15197 standard and Food and Drug Administration and consensus standards, respectively, 80.4% of measurements were within 15 mg/dl and 88.2% within 15% of reference values, 40% of measurements were within 7 mg/dl and 72.5% within 10% of reference values, and 65.2% of measurements were within 10 mg/dl and 82.7% within 12.5% of reference values. The TIR was slightly lower with the OptiScanner® than with the reference method. The J-index, standard deviation and maximal glucose change were the indices of glycemic variability least affected by the measurement device. CONCLUSIONS Based on the MARD, the performance of the OptiScanner® is adequate for use in ICU patients. Because recent standards for accuracy were not met, the OptiScanner® should not be used as a sole monitor. The assessment of glycemic variability is influenced by the time interval between BG determinations. TRIAL REGISTRATION Clinicaltrials.gov NCT01720381 . Registered 31 October 2012.
Collapse
Affiliation(s)
- Cláudia Righy Shinotsuka
- Department of Intensive Care, Erasme University Hospital, Université libre de Bruxelles, 808 route de Lennik, Brussels, B-1070 Belgium
| | - Alexandre Brasseur
- Department of Intensive Care, Erasme University Hospital, Université libre de Bruxelles, 808 route de Lennik, Brussels, B-1070 Belgium
| | - David Fagnoul
- Department of Intensive Care, Erasme University Hospital, Université libre de Bruxelles, 808 route de Lennik, Brussels, B-1070 Belgium
| | | | - Jean-Louis Vincent
- Department of Intensive Care, Erasme University Hospital, Université libre de Bruxelles, 808 route de Lennik, Brussels, B-1070 Belgium
| | - Jean-Charles Preiser
- Department of Intensive Care, Erasme University Hospital, Université libre de Bruxelles, 808 route de Lennik, Brussels, B-1070 Belgium
| |
Collapse
|
10
|
Joseph JI, Torjman MC, Strasma PJ. Vascular Glucose Sensor Symposium: Continuous Glucose Monitoring Systems (CGMS) for Hospitalized and Ambulatory Patients at Risk for Hyperglycemia, Hypoglycemia, and Glycemic Variability. J Diabetes Sci Technol 2015; 9:725-38. [PMID: 26078254 PMCID: PMC4525658 DOI: 10.1177/1932296815587938] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Hyperglycemia, hypoglycemia, and glycemic variability have been associated with increased morbidity, mortality, length of stay, and cost in a variety of critical care and non-critical care patient populations in the hospital. The results from prospective randomized clinical trials designed to determine the risks and benefits of intensive insulin therapy and tight glycemic control have been confusing; and at times conflicting. The limitations of point-of-care blood glucose (BG) monitoring in the hospital highlight the great clinical need for an automated real-time continuous glucose monitoring system (CGMS) that can accurately measure the concentration of glucose every few minutes. Automation and standardization of the glucose measurement process have the potential to significantly improve BG control, clinical outcome, safety and cost.
Collapse
Affiliation(s)
- Jeffrey I Joseph
- Sidney Kimmel Medical College of Thomas Jefferson University, Philadelphia, PA, USA
| | - Marc C Torjman
- Sidney Kimmel Medical College of Thomas Jefferson University, Philadelphia, PA, USA
| | | |
Collapse
|
11
|
Bochicchio GV, Hipszer BR, Magee MF, Bergenstal RM, Furnary AP, Gulino AM, Higgins MJ, Simpson PC, Joseph JI. Multicenter Observational Study of the First-Generation Intravenous Blood Glucose Monitoring System in Hospitalized Patients. J Diabetes Sci Technol 2015; 9:739-50. [PMID: 26033922 PMCID: PMC4525650 DOI: 10.1177/1932296815587939] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
BACKGROUND Current methods of blood glucose (BG) monitoring and insulin delivery are labor intensive and commonly fail to achieve the desired level of BG control. There is great clinical need in the hospital for a user-friendly bedside device that can automatically monitor the concentration of BG safely, accurately, frequently, and reliably. METHODS A 100-patient observation study was conducted at 6 US hospitals to evaluate the first generation of the Intravenous Blood Glucose (IVBG) System (Edwards Lifesciences LLC & Dexcom Inc). Device safety, accuracy, and reliability were assessed. A research nurse sampled blood from a vascular catheter every 4 hours for ≤ 72 hours and BG concentration was measured using the YSI 2300 STAT Plus Analyzer (YSI Life Sciences). The IVBG measurements were compared to YSI measurements to calculate point accuracy. RESULTS The IVBG systems logged more than 5500 hours of operation in 100 critical care patients without causing infection or inflammation of a vein. A total of 44135 IVBG measurements were performed in 100 patients with 30231 measurements from the subset of 75 patients used for accuracy analysis. In all, 996 IVBG measurements were time-matched with reference YSI measurements. These pairs had a mean absolute difference (MAD) of 11.61 mg/dl, a mean absolute relative difference (MARD) of 8.23%, 93% met 15/20% accuracy defined by International Organization for Standardization 15197:2003 standard, and 93.2% were in zone A of the Clarke error grid. The IVBG sensors were exposed to more than 200 different medications with no observable effect on accuracy. CONCLUSIONS The IVBG system is an automated and user-friendly glucose monitoring system that provides accurate and frequent BG measurements with great potential to improve the safety and efficacy of insulin therapy and BG control in the hospital, potentially leading to improved clinical outcomes.
Collapse
Affiliation(s)
| | | | - Michelle F Magee
- Georgetown University, Washington Hospital Center, Washington, DC, USA
| | | | - Anthony P Furnary
- Starr-Wood Cardiac Group, Providence Heart and Vascular Institute, Portland, OR, USA
| | | | | | | | | |
Collapse
|
12
|
Frost MC, Meyerhoff ME. Real-Time Monitoring of Critical Care Analytes in the Bloodstream with Chemical Sensors: Progress and Challenges. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2015; 8:171-92. [PMID: 26161973 DOI: 10.1146/annurev-anchem-071114-040443] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We review approaches and challenges in developing chemical sensor-based methods to accurately and continuously monitor levels of key analytes in blood related directly to the status of critically ill hospitalized patients. Electrochemical and optical sensor-based technologies have been pursued to measure important critical care species in blood [i.e., oxygen, carbon dioxide, pH, electrolytes (K(+), Na(+), Cl(-), etc.), glucose, and lactate] in real-time or near real-time. The two main configurations examined to date for achieving this goal have been intravascular catheter sensors and patient attached ex vivo sensors with intermittent blood sampling via an attached indwelling catheter. We discuss the status of these configurations and the main issues affecting the accuracy of the measurements, including cell adhesion and thrombus formation on the surface of the sensors, sensor drift, sensor selectivity, etc. Recent approaches to mitigate these nagging performance issues that have prevented these technologies from clinical use are also discussed.
Collapse
Affiliation(s)
- Megan C Frost
- Department of Biomedical Engineering, Michigan Technological University, Houghton, Michigan 49931-1295;
| | | |
Collapse
|