1
|
de Jong LA, Li X, Emamipour S, van der Werf S, Postma MJ, van Dijk PR, Feenstra TL. Evaluating the Cost-Utility of Continuous Glucose Monitoring in Individuals with Type 1 Diabetes: A Systematic Review of the Methods and Quality of Studies Using Decision Models or Empirical Data. PHARMACOECONOMICS 2024; 42:929-953. [PMID: 38904911 PMCID: PMC11343921 DOI: 10.1007/s40273-024-01388-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 04/22/2024] [Indexed: 06/22/2024]
Abstract
INTRODUCTION This review presents a critical appraisal of differences in the methodologies and quality of model-based and empirical data-based cost-utility studies on continuous glucose monitoring (CGM) in type 1 diabetes (T1D) populations. It identifies key limitations and challenges in health economic evaluations on CGM and opportunities for their improvement. METHODS The review and its documentation adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for systematic reviews. Searches for articles published between January 2000 and January 2023 were conducted using the MEDLINE, Embase, Web of Science, Cochrane Library, and Econlit databases. Published studies using models and empirical data to evaluate the cost utility of all CGM devices used by T1D patients were included in the search. Two authors independently extracted data on interventions, populations, model settings (e.g., perspectives and time horizons), model types and structures, clinical outcomes used to populate the model, validation, and uncertainty analyses. They subsequently met to confirm consensus. Quality was assessed using the Philips checklist for model-based studies and the Consensus Health Economic Criteria (CHEC) checklist for empirical studies. Model validation was assessed using the Assessment of the Validation Status of Health-Economic decision models (AdViSHE) checklist. The extracted data were used to generate summary tables and figures. The study protocol is registered with PROSPERO (CRD42023391284). RESULTS In total, 34 studies satisfied the selection criteria, two of which only used empirical data. The remaining 32 studies applied 10 different models, with a substantial majority adopting the CORE Diabetes Model. Model-based studies often lacked transparency, as their assumptions regarding the extrapolation of treatment effects beyond available evidence from clinical studies and the selection and processing of the input data were not explicitly stated. Initial scores for disagreements concerning checklists were relatively high, especially for the Philips checklist. Following their resolution, overall quality scores were moderate at 56%, whereas model validation scores were mixed. Strikingly, costing approaches differed widely across studies, resulting in little consistency in the elements included in intervention costs. DISCUSSION AND CONCLUSION The overall quality of studies evaluating CGM was moderate. Potential areas of improvement include developing systematic approaches for data selection, improving uncertainty analyses, clearer reporting, and explaining choices for particular modeling approaches. Few studies provided the assurance that all relevant and feasible options had been compared, which is required by decision makers, especially for rapidly evolving technologies such as CGM and insulin administration. High scores for disagreements indicated that several checklists contained questions that were difficult to interpret consistently for quality assessment. Therefore, simpler but comprehensive quality checklists may be needed for model-based health economic evaluation studies.
Collapse
Affiliation(s)
- Lisa A de Jong
- Department of Health Sciences, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Xinyu Li
- Groningen Research Institute of Pharmacy (GRIP), Faculty of Science and Engineering, University of Groningen, Groningen, The Netherlands
| | - Sajad Emamipour
- Department of Clinical Pharmacy and Pharmacology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Sjoukje van der Werf
- Central Medical Library, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Maarten J Postma
- Department of Health Sciences, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
- Department of Economics, Econometrics and Finance, Faculty of Economics and Business, University of Groningen, Groningen, The Netherlands
- Center of Excellence for Pharmaceutical Care Innovation, Universitas Padjadjaran, Bandung, Indonesia
- Department of Pharmacology and Therapy, Faculty of Medicine, Universitas Airlangga, Surabaya, Indonesia
| | - Peter R van Dijk
- Department of Endocrinology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
- Department of Internal Medicine, Diabetes Center, Isala, Zwolle, The Netherlands
| | - Talitha L Feenstra
- Groningen Research Institute of Pharmacy (GRIP), Faculty of Science and Engineering, University of Groningen, Groningen, The Netherlands.
- National Institute for Public Health and the Environment (RIVM), Bilthoven, The Netherlands.
| |
Collapse
|
2
|
Mathieu C, Ahmed W, Gillard P, Cohen O, Vigersky R, de Portu S, Ozdemir Saltik AZ. The Health Economics of Automated Insulin Delivery Systems and the Potential Use of Time in Range in Diabetes Modeling: A Narrative Review. Diabetes Technol Ther 2024; 26:66-75. [PMID: 38377319 DOI: 10.1089/dia.2023.0438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/22/2024]
Abstract
Intensive therapy with exogenous insulin is the treatment of choice for individuals living with type 1 diabetes (T1D) and some with type 2 diabetes, alongside regular glucose monitoring. The development of systems allowing (semi-)automated insulin delivery (AID), by connecting glucose sensors with insulin pumps and algorithms, has revolutionized insulin therapy. Indeed, AID systems have demonstrated a proven impact on overall glucose control, as indicated by effects on glycated hemoglobin (HbA1c), risk of severe hypoglycemia, and quality of life measures. An alternative endpoint for glucose control that has arisen from the use of sensor-based continuous glucose monitoring is the time in range (TIR) measure, which offers an indication of overall glucose control, while adding information on the quality of control with regard to blood glucose level stability. A review of literature on the health-economic value of AID systems was conducted, with a focus placed on the growing place of TIR as an endpoint in studies involving AID systems. Results showed that the majority of economic evaluations of AID systems focused on individuals with T1D and found AID systems to be cost-effective. Most studies incorporated HbA1c, rather than TIR, as a clinical endpoint to determine treatment effects on glucose control and subsequent quality-adjusted life year (QALY) gains. Likely reasons for the choice of HbA1c as the chosen endpoint is the use of this metric in most validated and established economic models, as well as the limited publicly available evidence on appropriate methodologies for TIR data incorporation within conventional economic evaluations. Future studies could include the novel TIR metric in health-economic evaluations as an additional measure of treatment effects and subsequent QALY gains, to facilitate a holistic representation of the impact of AID systems on glycemic control. This would provide decision makers with robust evidence to inform future recommendations for health care interventions.
Collapse
Affiliation(s)
- Chantal Mathieu
- Department of Endocrinology, UZ Gasthuisberg, Leuven, Belgium
| | - Waqas Ahmed
- Covalence Research Ltd, Harpenden, United Kingdom
| | - Pieter Gillard
- Department of Endocrinology, UZ Gasthuisberg, Leuven, Belgium
| | - Ohad Cohen
- Medtronic International Trading Sarl, Tolochenaz, Switzerland
| | | | - Simona de Portu
- Medtronic International Trading Sarl, Tolochenaz, Switzerland
| | | |
Collapse
|
3
|
Bernabe-Ortiz A, Carrillo-Larco RM, Safary E, Vetter B, Lazo-Porras M. Use of continuous glucose monitors in low- and middle-income countries: A scoping review. Diabet Med 2023; 40:e15089. [PMID: 36929661 DOI: 10.1111/dme.15089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 02/21/2023] [Accepted: 03/13/2023] [Indexed: 03/18/2023]
Abstract
AIMS The use of continuous glucose monitors (CGMs) has been shown to have positive impact on diabetes management for people with type 1 diabetes (T1DM), type 2 diabetes (T2DM) and gestational diabetes (GDM) in high-income countries. However, as useful as CGMs are, the experience in low- and middle-income countries (LMICs) is limited and has not been summarized. METHODS A scoping review of the scientific literature was conducted. Medline, Embase, Global Health and Scopus were used to seek original research conducted in LMICs. The search results were screened by two reviewers independently. We included studies assessing health outcomes following the use of CGMs at the individual level (e.g. glycaemic control or complications) and at the health system level (e.g. barriers, facilitators and cost-effectiveness) in English, Portuguese, Spanish and French. Results were summarized narratively. RESULTS From 4772 records found in database search, 27 reports were included; most of them from China (n = 7), Colombia (n = 5) and India (n = 4). Thirteen reports studied T1DM, five T2DM, seven both T1DM and T2DM and two GDM. Seven reports presented results of experimental studies (five randomized trials and two quasi-experimental); two on cost-effective analysis and the remaining 18 were observational. Studies showed that CGMs improved surrogate glycaemic outcomes (HbA1c reduction), hard endpoints (lower hospitalization rates and diabetes complications) and patient-oriented outcomes (quality of life). However, several caveats were identified: mostly observational studies, few participants in trials, short follow-up and focused on surrogate outcomes. CONCLUSIONS The scoping review identified that studies about CGMs in LMICs have several limitations. Stronger study designs, appropriate sample sizes and the inclusion of patient-important outcomes should be considered to inform the evidence about CGMs for the management of people with diabetes in LMICs.
Collapse
Affiliation(s)
- Antonio Bernabe-Ortiz
- CRONICAS Center of Excellence in Chronic Diseases, Universidad Peruana Cayetano Heredia, Lima, Peru
- Universidad Científica del Sur, Lima, Peru
| | - Rodrigo M Carrillo-Larco
- Emory Global Diabetes Research Center, Emory University, Atlanta, Georgia, USA
- Hubert Department of Global Health, Rollins School of Public Health, Emory University, Atlanta, Georgia, USA
| | | | | | - María Lazo-Porras
- CRONICAS Center of Excellence in Chronic Diseases, Universidad Peruana Cayetano Heredia, Lima, Peru
- Division of Tropical and Humanitarian Medicine, University of Geneva and Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
4
|
Sherr JL, Schoelwer M, Dos Santos TJ, Reddy L, Biester T, Galderisi A, van Dyk JC, Hilliard ME, Berget C, DiMeglio LA. ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery. Pediatr Diabetes 2022; 23:1406-1431. [PMID: 36468192 DOI: 10.1111/pedi.13421] [Citation(s) in RCA: 52] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Accepted: 09/24/2022] [Indexed: 12/11/2022] Open
Affiliation(s)
- Jennifer L Sherr
- Department of Pediatrics, Yale School of Medicine, Yale University, New Haven, Connecticut, USA
| | - Melissa Schoelwer
- Center for Diabetes Technology, University of Virginia, Charlottesville, Virginia, USA
| | | | - Leenatha Reddy
- Department of Pediatrics Endocrinology, Rainbow Children's Hospital, Hyderabad, India
| | - Torben Biester
- AUF DER BULT, Hospital for Children and Adolescents, Hannover, Germany
| | - Alfonso Galderisi
- Department of Woman and Child's Health, University of Padova, Padova, Italy
| | | | - Marisa E Hilliard
- Department of Pediatrics, Baylor College of Medicine and Texas Children's Hospital, Houston, Texas, USA
| | - Cari Berget
- Barbara Davis Center, University of Colorado School of Medicine, Aurora, Colorado, USA
| | - Linda A DiMeglio
- Department of Pediatrics, Indiana University School of Medicine, Indianapolis, Indiana, USA
| |
Collapse
|
5
|
Jiao Y, Lin R, Hua X, Churilov L, Gaca MJ, James S, Clarke PM, O'Neal D, Ekinci EI. A systematic review: Cost-effectiveness of continuous glucose monitoring compared to self-monitoring of blood glucose in type 1 diabetes. Endocrinol Diabetes Metab 2022; 5:e369. [PMID: 36112608 PMCID: PMC9659662 DOI: 10.1002/edm2.369] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 08/19/2022] [Accepted: 08/28/2022] [Indexed: 12/15/2022] Open
Abstract
Continuous glucose monitoring (CGM) is rapidly becoming a vital tool in the management of type 1 diabetes. Its use has been shown to improve glycaemic management and reduce the risk of hypoglycaemic events. The cost of CGM remains a barrier to its widespread application. We aimed to identify and synthesize evidence about the cost-effectiveness of utilizing CGM in patients with type 1 diabetes. Studies were identified from MEDLINE, Embase and Cochrane Library from January 2010 to February 2022. Those that assessed the cost-effectiveness of CGM compared to self-monitored blood glucose (SMBG) in patients with type 1 diabetes and reported lifetime incremental cost-effectiveness ratio (ICER) were included. Studies on critically ill or pregnant patients were excluded. Nineteen studies were identified. Most studies compared continuous subcutaneous insulin infusion and SMBG to a sensor-augmented pump (SAP). The estimated ICER range was [$18,734-$99,941] and the quality-adjusted life year (QALY) gain range was [0.76-2.99]. Use in patients with suboptimal management or greater hypoglycaemic risk revealed more homogenous results and lower ICERs. Limited studies assessed CGM in the context of multiple daily injections (MDI) (n = 4), MDI and SMBG versus SAP (n = 2) and three studies included hybrid closed-loop systems. Most studies (n = 17) concluded that CGM is a cost-effective tool. This systematic review suggests that CGM appears to be a cost-effective tool for individuals with type 1 diabetes. Cost-effectiveness is driven by reducing short- and long-term complications. Use in patients with suboptimal management or at risk of severe hypoglycaemia is most cost-effective.
Collapse
Affiliation(s)
- Yuxin Jiao
- Austin HealthHeidelbergVictoriaAustralia
| | - Rose Lin
- Austin HealthHeidelbergVictoriaAustralia
| | - Xinyang Hua
- Centre for Health PolicyMelbourne School of Population and Global HealthUniversity of MelbourneCarltonVictoriaAustralia
| | - Leonid Churilov
- Melbourne Medical SchoolThe University of MelbourneParkvilleVictoriaAustralia
| | - Michele J. Gaca
- Health Sciences LibraryAustin HealthHeidelbergVictoriaAustralia
| | - Steven James
- School of Nursing, Midwifery and ParamedicineUniversity of the Sunshine CoastPetrieQueenslandAustralia
| | - Philip M. Clarke
- Health Economics Research CentreNuffield Department of Population HealthUniversity of OxfordOxfordUK
| | - David O'Neal
- Department of MedicineSt Vincent's Hospital Melbourne, Melbourne Medical School, The University of MelbourneParkvilleVictoriaAustralia
| | - Elif I. Ekinci
- Department of Medicine, Austin HealthMelbourne Medical School, The University of MelbourneParkvilleVictoriaAustralia,Department of EndocrinologyAustin HealthHeidelbergVictoriaAustralia
| |
Collapse
|
6
|
Nagi MA, Dewi PEN, Thavorncharoensap M, Sangroongruangsri S. A Systematic Review on Economic Evaluation Studies of Diagnostic and Therapeutic Interventions in the Middle East and North Africa. APPLIED HEALTH ECONOMICS AND HEALTH POLICY 2022; 20:315-335. [PMID: 34931297 DOI: 10.1007/s40258-021-00703-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 11/22/2021] [Indexed: 06/14/2023]
Abstract
INTRODUCTION Due to the increase in healthcare budget constraint, economic evaluation (EE) evidence is increasingly required to inform resource allocation decisions. This study aimed to systematically review quantity, characteristics, and quality of full EE studies on diagnostic and therapeutic interventions conducted in 26 Middle East and North Africa (MENA) countries. METHODS PubMed and Scopus databases were comprehensively searched to identify the published EE studies in the MENA region. The quality of reviewed studies was evaluated using the Consolidated Health Economic Evaluation Reporting Standards (CHEERS) checklist. RESULTS The search identified 69 studies. The cost-utility approach was adopted in 49 studies (71 %). More than half (38 studies; 55 %) were conducted in Iran and Turkey. Sixteen countries (62 %) did not have any EE studies. The most frequently analyzed therapeutic areas were infectious diseases (19 studies; 28 %), cardiovascular diseases (11 studies; 16 %), and malignancies (10 studies; 14 %). Ten studies (14 %), 46 (67 %), 12 (17 %), and 1 study (1 %) were classified as excellent, high, moderate, and poor quality, respectively. The mean of items reported was 85.10 % (standard deviation 13.32 %). Characterizing heterogeneity, measurement of effectiveness, time horizon, and discount rate were missed in 21 (60 %), 22 (32 %), 20 (29 %) and 15 (25 %) studies, respectively. Data on effectiveness and utility relied primarily on studies conducted outside the region. CONCLUSIONS The quantity of EE studies in the MENA region remains low; however, overall quality is high to excellent. The availability of local data, capacity building, and national guidelines are vital to improve both the quantity and quality of EE studies in the region.
Collapse
Affiliation(s)
- Mouaddh Abdulmalik Nagi
- Doctor of Philosophy Program in Social, Economic, and Administrative Pharmacy, Department of Pharmacy, Faculty of Pharmacy, Mahidol University, Bangkok, Thailand.
- Faculty of Medical Sciences, Aljanad University for Science and Technology, Taiz, Yemen.
| | - Pramitha Esha Nirmala Dewi
- Doctor of Philosophy Program in Social, Economic, and Administrative Pharmacy, Department of Pharmacy, Faculty of Pharmacy, Mahidol University, Bangkok, Thailand
- Department of Pharmacy Profession, Faculty of Medicine and health Sciences, Universitas Muhammadiyah Yogyakarta, Yogyakarta, Indonesia
| | - Montarat Thavorncharoensap
- Social and Administrative Pharmacy Excellence Research (SAPER) Unit, Department of Pharmacy, Faculty of Pharmacy, Mahidol University, Bangkok, 10400, Thailand
| | - Sermsiri Sangroongruangsri
- Social and Administrative Pharmacy Division, Department of Pharmacy, Faculty of Pharmacy, Mahidol University, Bangkok, 10400, Thailand
| |
Collapse
|