Bass K, Momin MAM, Howe C, Aladwani G, Strickler S, Kolanjiyil AV, Hindle M, DiBlasi RM, Longest W. Characterizing the Effects of Nasal Prong Interfaces on Aerosol Deposition in a Preterm Infant Nasal Model. AAPS PharmSciTech 2022; 23:114. [PMID: 35441324 DOI: 10.1208/s12249-022-02259-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 03/20/2022] [Indexed: 11/30/2022] Open
Abstract
The objective of this study was to characterize the effects of multiple nasal prong interface configurations on nasal depositional loss of pharmaceutical aerosols in a preterm infant nose-throat (NT) airway model. Benchmark in vitro experiments were performed in which a spray-dried powder formulation was delivered to a new preterm NT model with a positive-pressure infant air-jet dry powder inhaler using single- and dual-prong interfaces. These results were used to develop and validate a computational fluid dynamics (CFD) model of aerosol transport and deposition in the NT geometry. The validated CFD model was then used to explore the NT depositional characteristic of multiple prong types and configurations. The CFD model highlighted a turbulent jet effect emanating from the prong(s). Analysis of NT aerosol deposition efficiency curves for a characteristic particle size and delivery flowrate (3 µm and 1.4 L/min (LPM)) revealed little difference in NT aerosol deposition fraction (DF) across the prong insertion depths of 2-5 mm (DF = 16-24%) with the exception of a single prong with 5-mm insertion (DF = 36%). Dual prongs provided a modest reduction in deposition vs. a single aerosol delivery prong at the same flow for insertion depths < 5 mm. The presence of the prongs increased nasal depositional loss by absolute differences in the range of 20-70% compared with existing correlations for ambient aerosols. In conclusion, the use of nasal prongs was shown to have a significant impact on infant NT aerosol depositional loss prompting the need for prong design alterations to improve lung delivery efficiency.
Collapse
|
2
|
Longest W, Spence B, Hindle M. Devices for Improved Delivery of Nebulized Pharmaceutical Aerosols to the Lungs. J Aerosol Med Pulm Drug Deliv 2019; 32:317-339. [PMID: 31287369 DOI: 10.1089/jamp.2018.1508] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Nebulizers have a number of advantages for the delivery of inhaled pharmaceutical aerosols, including the use of aqueous formulations and the ability to deliver process-sensitive proteins, peptides, and biological medications. A frequent disadvantage of nebulized aerosols is poor lung delivery efficiency, which wastes valuable medications, increases delivery times, and may increase side effects of the medication. A focus of previous development efforts and previous nebulizer reviews, has been an improvement of the underlying nebulization technology controlling the breakup of a liquid into droplets. However, for a given nebulization technology, a wide range of secondary devices and strategies can be implemented to significantly improve lung delivery efficiency of the aerosol. This review focuses on secondary devices and technologies that can be implemented to improve the lung delivery efficiency of nebulized aerosols and potentially target the region of drug delivery within the lungs. These secondary devices may (1) modify the aerosol size distribution, (2) synchronize aerosol delivery with inhalation, (3) reduce system depositional losses at connection points, (4) improve the patient interface, or (5) guide patient inhalation. The development of these devices and technologies is also discussed, which often includes the use of computational fluid dynamic simulations, three-dimensional printing and rapid prototype device and airway model construction, realistic in vitro experiments, and in vivo analysis. Of the devices reviewed, the implementation of streamlined components may be the most direct and lowest cost approach to enhance aerosol delivery efficiency within nonambulatory nebulizer systems. For applications involving high-dose medications or precise dose administration, the inclusion of active devices to control aerosol size, guide inhalation, and synchronize delivery with inhalation hold considerable promise.
Collapse
Affiliation(s)
- Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia.,Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Benjamin Spence
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| |
Collapse
|
3
|
Ghosh S, Pleasants RA, Ohar JA, Donohue JF, Drummond MB. Prevalence and factors associated with suboptimal peak inspiratory flow rates in COPD. Int J Chron Obstruct Pulmon Dis 2019; 14:585-595. [PMID: 30880948 PMCID: PMC6402615 DOI: 10.2147/copd.s195438] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose Adequate peak inspiratory flow rate (PIFR) is required for drug dispersion with dry powder inhalers (DPIs). Prevalence of PIFR discordance (suboptimal PIFR with prescribed inhalers) and factors influencing device-specific PIFR are unclear in COPD. The objective of this study was to determine the prevalence of PIFR discordance and associated clinical factors in a stable COPD population. Patients and methods An observational, single-center, cohort study was conducted including 66 outpatients with COPD. PIFR was measured using the In-Check™ Dial with applied resistance of prescribed inhalers. Participants were defined as discordant if measured PIFR was <30 L/min and <60 L/min for high and low–medium resistance devices, respectively, using an inspiratory effort the participant normally used with their prescribed DPI. Results The median age of the COPD participants was 69.4 years, 92% were white and 47% were female. A total of 48% were using low–medium resistance DPIs (Diskus®/Ellipta®) and 76% used high-resistance DPI (Handihaler®). A total of 40% of COPD participants were discordant to prescribed inhalers. Female gender was the only factor consistently associated with lower PIFR. Shorter height was associated with reduced PIFR for low–medium resistance (r=0.44; P=0.01), but not high resistance (r=0.20; P=0.16). There was no correlation between PIFR by In-Check™ dial and PIFR measured by standard spirometer. Conclusion PIFR is reduced in stable COPD patients, with female gender being the only factor consistently associated with reduced PIFR. Discordance with prescribed inhalers was seen in 40% of COPD patients, suggesting that many COPD patients do not generate adequate inspiratory force to overcome prescribed DPIs resistance in the course of normal use.
Collapse
Affiliation(s)
- Sohini Ghosh
- Division of Pulmonary Diseases and Critical Medicine, Department of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA,
| | | | - Jill A Ohar
- Department of Medicine, Section of Pulmonary, Critical Care, Allergy, and Immunology, School of Medicine, Wake Forest University, Winston-Salem, NC, USA
| | - James F Donohue
- Division of Pulmonary Diseases and Critical Medicine, Department of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA,
| | - M Bradley Drummond
- Division of Pulmonary Diseases and Critical Medicine, Department of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA,
| |
Collapse
|
4
|
Longest PW, Bass K, Dutta R, Rani V, Thomas ML, El-Achwah A, Hindle M. Use of computational fluid dynamics deposition modeling in respiratory drug delivery. Expert Opin Drug Deliv 2019; 16:7-26. [PMID: 30463458 PMCID: PMC6529297 DOI: 10.1080/17425247.2019.1551875] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Accepted: 11/20/2018] [Indexed: 10/27/2022]
Abstract
INTRODUCTION Respiratory drug delivery is a surprisingly complex process with a number of physical and biological challenges. Computational fluid dynamics (CFD) is a scientific simulation technique that is capable of providing spatially and temporally resolved predictions of many aspects related to respiratory drug delivery from initial aerosol formation through respiratory cellular drug absorption. AREAS COVERED This review article focuses on CFD-based deposition modeling applied to pharmaceutical aerosols. Areas covered include the development of new complete-airway CFD deposition models and the application of these models to develop a next-generation of respiratory drug delivery strategies. EXPERT OPINION Complete-airway deposition modeling is a valuable research tool that can improve our understanding of pharmaceutical aerosol delivery and is already supporting medical hypotheses, such as the expected under-treatment of the small airways in asthma. These complete-airway models are also being used to advance next-generation aerosol delivery strategies, like controlled condensational growth. We envision future applications of CFD deposition modeling to reduce the need for human subject testing in developing new devices and formulations, to help establish bioequivalence for the accelerated approval of generic inhalers, and to provide valuable new insights related to drug dissolution and clearance leading to microdosimetry maps of drug absorption.
Collapse
Affiliation(s)
- P. Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, USA
| | - Karl Bass
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Rabijit Dutta
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Vijaya Rani
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Morgan L. Thomas
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Ahmad El-Achwah
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, USA
| |
Collapse
|
5
|
Martin AR, Moore CP, Finlay WH. Models of deposition, pharmacokinetics, and intersubject variability in respiratory drug delivery. Expert Opin Drug Deliv 2018; 15:1175-1188. [PMID: 30388902 DOI: 10.1080/17425247.2018.1544616] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
INTRODUCTION Aerosol drug delivery to the lungs via inhalation is widely used in the treatment of respiratory diseases. The deposition pattern of inhaled particles within the airways of the respiratory tract is key in determining the initial delivered dose. Thereafter, dose-dependent processes including drug release or dissolution, clearance, and absorption influence local and systemic exposure to inhaled drugs over time. AREAS COVERED Empirical correlations, numerical simulation, and in vitro airway geometries that permit improved prediction of extrathoracic and lung deposition fractions in a variety of age groups and breathing conditions are described. Efforts to link deposition models with pharmacokinetic models predicting lung and systemic exposure to inhaled drugs over time are then reviewed. Finally, new methods to predict intersubject variability in extrathoracic deposition, capturing variability in both size and shape of the upper airways, are highlighted. EXPERT OPINION Recent work has been done to expand in vitro deposition experiments to a wide range of age groups and breathing conditions, to link regional lung deposition models with pharmacokinetic models, and to improve prediction of intersubject variability. These efforts are improving predictive understanding of respiratory drug delivery, and will aid the development of new inhaled drugs and delivery devices.
Collapse
Affiliation(s)
- Andrew R Martin
- a Department of Mechanical Engineering , University of Alberta , Edmonton , AB , Canada
| | - Charles P Moore
- a Department of Mechanical Engineering , University of Alberta , Edmonton , AB , Canada
| | - Warren H Finlay
- a Department of Mechanical Engineering , University of Alberta , Edmonton , AB , Canada
| |
Collapse
|
6
|
Longest PW, Tian G, Khajeh-Hosseini-Dalasm N, Hindle M. Validating Whole-Airway CFD Predictions of DPI Aerosol Deposition at Multiple Flow Rates. J Aerosol Med Pulm Drug Deliv 2016; 29:461-481. [PMID: 27082824 PMCID: PMC5220557 DOI: 10.1089/jamp.2015.1281] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2015] [Accepted: 02/05/2016] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND The objective of this study was to compare aerosol deposition predictions of a new whole-airway CFD model with available in vivo data for a dry powder inhaler (DPI) considered across multiple inhalation waveforms, which affect both the particle size distribution (PSD) and particle deposition. METHODS The Novolizer DPI with a budesonide formulation was selected based on the availability of 2D gamma scintigraphy data in humans for three different well-defined inhalation waveforms. Initial in vitro cascade impaction experiments were conducted at multiple constant (square-wave) particle sizing flow rates to characterize PSDs. The whole-airway CFD modeling approach implemented the experimentally determined PSDs at the point of aerosol formation in the inhaler. Complete characteristic airway geometries for an adult were evaluated through the lobar bronchi, followed by stochastic individual pathway (SIP) approximations through the tracheobronchial region and new acinar moving wall models of the alveolar region. RESULTS It was determined that the PSD used for each inhalation waveform should be based on a constant particle sizing flow rate equal to the average of the inhalation waveform's peak inspiratory flow rate (PIFR) and mean flow rate [i.e., AVG(PIFR, Mean)]. Using this technique, agreement with the in vivo data was acceptable with <15% relative differences averaged across the three regions considered for all inhalation waveforms. Defining a peripheral to central deposition ratio (P/C) based on alveolar and tracheobronchial compartments, respectively, large flow-rate-dependent differences were observed, which were not evident in the original 2D in vivo data. CONCLUSIONS The agreement between the CFD predictions and in vivo data was dependent on accurate initial estimates of the PSD, emphasizing the need for a combination in vitro-in silico approach. Furthermore, use of the AVG(PIFR, Mean) value was identified as a potentially useful method for characterizing a DPI aerosol at a constant flow rate.
Collapse
Affiliation(s)
- P. Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Geng Tian
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia
| | | | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| |
Collapse
|
7
|
Ruzycki CA, Javaheri E, Finlay WH. The use of computational fluid dynamics in inhaler design. Expert Opin Drug Deliv 2013; 10:307-23. [PMID: 23289401 DOI: 10.1517/17425247.2013.753053] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
INTRODUCTION Computational fluid dynamics (CFD) has recently seen increased use in the design of pharmaceutical inhalers. The use of CFD in the design of inhalers is made difficult by the complex nature of aerosol generation. At present, CFD has provided valuable insight into certain aspects of inhaler performance, though limitations in computational power have prevented the full implementation of numerical methods in the design of inhalers. AREAS COVERED This review examines the application of CFD in the design of aerosol drug delivery technologies with a focus on pressurized metered-dose inhalers (pMDI), nebulizers and dry powder inhalers (DPIs). Challenges associated with the application of CFD in inhaler design are discussed along with relevant investigations in the literature. Discussions of discrete element modeling (DEM) and the simulation of pharmaceutical aerosol dispersion are included. EXPERT OPINION The extreme complexity of coupled fluid and aerosol dynamics associated with aerosol generation has somewhat limited the use of CFD in inhaler design. Combined CFD--DEM simulations provide a useful tool in the design of DPIs, though aerosol generation in pMDIs and nebulizers has eluded CFD modeling. The most beneficial use of CFD typically occurs when concurrent CFD and experimental analyses are performed, significantly enhancing the knowledge provided by experiment alone.
Collapse
Affiliation(s)
- Conor A Ruzycki
- University of Alberta, Department of Mechanical Engineering , Edmonton, Alberta T6G 2G8, Canada
| | | | | |
Collapse
|
8
|
Martin AR, Katz IM, Lipsitz Y, Terzibachi K, Caillibotte G, Texereau J. Methods for evaluation of helium/oxygen delivery through non-rebreather facemasks. Med Gas Res 2012; 2:31. [PMID: 23244700 PMCID: PMC3557179 DOI: 10.1186/2045-9912-2-31] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2012] [Accepted: 12/12/2012] [Indexed: 11/10/2022] Open
Abstract
UNLABELLED BACKGROUND Inhalation of low-density helium/oxygen mixtures has been used both to lower the airway resistance and work of breathing of patients with obstructive lung disease and to transport pharmaceutical aerosols to obstructed lung regions. However, recent clinical investigations have highlighted the potential for entrainment of room air to dilute helium/oxygen mixtures delivered through non-rebreather facemasks, thereby increasing the density of the inhaled gas mixture and limiting intended therapeutic effects. This article describes the development of benchtop methods using face models for evaluating delivery of helium/oxygen mixtures through facemasks. METHODS Four face models were used: a flat plate, a glass head manikin, and two face manikins normally used in life support training. A mechanical test lung and ventilator were employed to simulate spontaneous breathing during delivery of 78/22 %vol helium/oxygen through non-rebreather facemasks. Based on comparison of inhaled helium concentrations with available clinical data, one face model was selected for measurements made during delivery of 78/22 or 65/35 %vol helium/oxygen through three different masks as tidal volume varied between 500 and 750 ml, respiratory rate between 14 and 30 breaths/min, the inspiratory/expiratory ratio between 1/2 and 1/1, and the supply gas flow rate between 4 and 15 l/min. Inhaled helium concentrations were measured both with a thermal conductivity analyzer and using a novel flow resistance method. RESULTS Face models borrowed from life support training provided reasonably good agreement with available clinical data. After normalizing for the concentration of helium in the supply gas, no difference was noted in the extent of room air entrainment when delivering 78/22 versus 65/35 %vol helium/oxygen. For a given mask fitted to the face in a reproducible manner, delivered helium concentrations were primarily determined by the ratio of supply gas flow rate to simulated patient minute ventilation, with the inspiratory/expiratory ratio playing a secondary role. However, the functional dependence of helium concentration on these two ratios depended on the mask design. CONCLUSIONS Large differences in mask performance were identified. With continued refinement, the availability of reliable benchtop methods is expected to assist in the development and selection of patient interfaces for delivery of helium/oxygen and other medical gases.
Collapse
Affiliation(s)
- Andrew R Martin
- Delaware Research and Technology Center, American Air Liquide, Newark, DE, 19702, USA.
| | | | | | | | | | | |
Collapse
|
9
|
Longest PW, Tian G, Walenga RL, Hindle M. Comparing MDI and DPI aerosol deposition using in vitro experiments and a new stochastic individual path (SIP) model of the conducting airways. Pharm Res 2012; 29:1670-88. [PMID: 22290350 DOI: 10.1007/s11095-012-0691-y] [Citation(s) in RCA: 110] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2011] [Accepted: 01/19/2012] [Indexed: 12/26/2022]
Abstract
PURPOSE Deposition characteristics of MDI and DPI aerosols were compared throughout the conducting airways for the first time using a combination of in vitro experiments and a newly developed stochastic individual path (SIP) model for different inhalation profiles. METHODS In vitro experiments were used to determine initial particle distribution profiles and to validate computational fluid dynamics (CFD) model results for a MDI and DPI delivering the same dose of drug in a geometry of the mouth-throat and tracheobronchial airways. The validated CFD model was then used to predict the transport and deposition of the drug using correct and incorrect inhalation profiles for each inhaler. RESULTS The MDI delivered approximately two times more drug to the tracheobronchial region compared with the DPI for both correct and incorrect inhalation profiles. Errors in inhalation reduced the deposited tracheobronchial dose by approximately 30% for both inhalers. The DPI delivered the largest dose to the mouth-throat (~70%) and the MDI delivered the largest dose to the alveolar airways (~50%). CONCLUSIONS The developed in silico model provides new insights into the lung delivery of pharmaceutical aerosols and can be applied in future studies in combination with pharmacokinetic analysis to establish bioequivalence between devices.
Collapse
Affiliation(s)
- P Worth Longest
- Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, Virginia 23284-3015, USA.
| | | | | | | |
Collapse
|
10
|
Developing an efficient and reliable dry powder inhaler for pulmonary drug delivery – A review for multidisciplinary researchers. Med Eng Phys 2012; 34:409-27. [DOI: 10.1016/j.medengphy.2011.12.025] [Citation(s) in RCA: 123] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2011] [Revised: 11/15/2011] [Accepted: 12/30/2011] [Indexed: 11/18/2022]
|
11
|
Longest PW, Holbrook LT. In silico models of aerosol delivery to the respiratory tract - development and applications. Adv Drug Deliv Rev 2012; 64:296-311. [PMID: 21640772 PMCID: PMC3258464 DOI: 10.1016/j.addr.2011.05.009] [Citation(s) in RCA: 115] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2011] [Revised: 05/12/2011] [Accepted: 05/19/2011] [Indexed: 10/18/2022]
Abstract
This review discusses the application of computational models to simulate the transport and deposition of inhaled pharmaceutical aerosols from the site of particle or droplet formation to deposition within the respiratory tract. Traditional one-dimensional (1-D) whole-lung models are discussed briefly followed by a more in-depth review of three-dimensional (3-D) computational fluid dynamics (CFD) simulations. The review of CFD models is organized into sections covering transport and deposition within the inhaler device, the extrathoracic (oral and nasal) region, conducting airways, and alveolar space. For each section, a general review of significant contributions and advancements in the area of simulating pharmaceutical aerosols is provided followed by a more in-depth application or case study that highlights the challenges, utility, and benefits of in silico models. Specific applications presented include the optimization of an existing spray inhaler, development of charge-targeted delivery, specification of conditions for optimal nasal delivery, analysis of a new condensational delivery approach, and an evaluation of targeted delivery using magnetic aerosols. The review concludes with recommendations on the need for more refined model validations, use of a concurrent experimental and CFD approach for developing aerosol delivery systems, and development of a stochastic individual path (SIP) model of aerosol transport and deposition throughout the respiratory tract.
Collapse
Affiliation(s)
- P Worth Longest
- Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, United States.
| | | |
Collapse
|
12
|
Verbanck S, Kalsi HS, Biddiscombe MF, Agnihotri V, Belkassem B, Lacor C, Usmani OS. Inspiratory and expiratory aerosol deposition in the upper airway. Inhal Toxicol 2011; 23:104-11. [PMID: 21309663 DOI: 10.3109/08958378.2010.547535] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Aerosol deposition efficiency (DE) in the extrathoracic airways during mouth breathing is currently documented only for the inspiratory phase of respiration, and there is a need for quantification of expiratory DE. Our aim was to study both inspiratory and expiratory DE in a realistic upper airway geometry. This was done experimentally on a physical upper airway cast by scintigraphy, and numerically by computational fluid dynamic simulations using a Reynolds Averaged Navier?Stokes (RANS) method with a k-? SST turbulence model coupled with a stochastic Lagrangian approach. Experiments and simulations were carried out for particle sizes (3 and 6 μm) and flow rates (30 and 60 L/min) spanning the ranges of Stokes (Stk) and Reynolds (Re) number pertinent to therapeutic and environmental aerosols. We showed that inspiratory total deposition data obtained by scintigraphy fell onto a previously published deposition curve representative of a range of upper airway geometries. We also found that expiratory and inspiratory DE curves were almost identical. Finally, DE in different compartments of the upper airway model showed a very different distribution pattern of aerosol deposition during inspiration and expiration, with preferential deposition in oral and pharyngeal compartments, respectively. These compartmental deposition patterns were very consistent and only slightly dependent on particle size or flow rate. Total deposition for inspiration and expiration was reasonably well-mimicked by the RANS simulation method we employed, and more convincingly so in the upper range of the Stk and Re number. However, compartmental deposition patterns showed discrepancies between experiments and RANS simulations, particularly during expiration.
Collapse
Affiliation(s)
- S Verbanck
- Respiratory Division, University Hospital UZ Brussel, Brussels, Belgium.
| | | | | | | | | | | | | |
Collapse
|
13
|
Watts AB, McConville JT, Williams RO. Current therapies and technological advances in aqueous aerosol drug delivery. Drug Dev Ind Pharm 2008; 34:913-22. [PMID: 18663654 DOI: 10.1080/03639040802144211] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Recent advances in aerosolization technology have led to renewed interest in pulmonary delivery of a variety of drugs. Pressurized metered dose inhalers (pMDIs) and dry powder inhalers (DPIs) have experienced success in recent years; however, many limitations are presented by formulation difficulties, inefficient delivery, and complex device designs. Simplification of the formulation process as well as adaptability of new devices has led many in the pharmaceutical industry to reconsider aerosolization in an aqueous carrier. In the acute care setting, breath-enhanced air-jet nebulizers are controlling and minimizing the amount of wasted medication, while producing a high percentage of respirable droplets. Vibrating mesh nebulizers offer advantages in higher respirable fractions (RFs) and slower velocity aerosols when compared with air-jet nebulizers. Vibrating mesh nebulizers incorporating formulation and patient adaptive components provide improvements to continuous nebulization technology by generating aerosol only when it is most likely to reach the deep lung. Novel innovations in generation of liquid aerosols are now being adapted for propellant-free pulmonary drug delivery to achieve unprecedented control over dose delivered and are leading the way for the adaptation of systemic drugs for delivery via the pulmonary route. Devices designed for the metered dose delivery of insulin, morphine, sildenafil, triptans, and various peptides are all currently under investigation for pulmonary delivery to treat nonrespiratory diseases. Although these devices are currently still in clinical testing (with the exception of the Respimat), metered dose liquid inhalers (MDLIs) have already shown superior outcomes to current pulmonary and systemic delivery methods.