Ke WR, Chang RYK, Kwok PCL, Tang P, Chen L, Chen D, Chan HK. Administration of dry powders during respiratory supports. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:596. [PMID: 33987294 DOI: 10.21037/atm-20-3946] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Inhaled drugs are routinely used for the treatment of respiratory-supported patients. To date, pressurized metered dose inhalers and nebulizers are the two platforms routinely employed in the clinical setting. The scarce utilization of the dry powder inhaler (DPI) platform is partly due to the lack of in vivo data that proves optimal delivery and drug efficacy are achievable. Additionally, fitting a DPI in-line to the respiratory circuit is not as straightforward as with the other aerosol delivery platforms. Importantly, there is a common misconception that the warm and humidified inspiratory air in respiratory supports, even for a short exposure, will deteriorate powder formulation compromising its delivery and efficacy. However, some recent studies have dispelled this myth, showing successful delivery of dry powders through the humidified circuit of respiratory supports. Compared with other aerosol delivery devices, the use of DPIs during respiratory supports possesses unique advantages such as rapid delivery and high dose. In this review, we presented in vitro studies showing various setups employing commercial DPIs and effects of ventilator parameters on the aerosol delivery. Inclusion of novel DPIs was also made to illustrate characteristics of an ideal inhaler that would give high lung dose with low powder deposition loss in tracheal tubes and respiratory circuits. Clinical trials are urgently needed to confirm the benefits of administration of dry powders in ventilated patients, thus enabling translation of powder delivery into practice.
Collapse
Affiliation(s)
- Wei-Ren Ke
- Advanced Drug Delivery Group, School of Pharmacy, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Rachel Yoon Kyung Chang
- Advanced Drug Delivery Group, School of Pharmacy, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Philip Chi Lip Kwok
- Advanced Drug Delivery Group, School of Pharmacy, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Patricia Tang
- Advanced Drug Delivery Group, School of Pharmacy, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Lan Chen
- Hangzhou Chance Pharmaceuticals, Hangzhou, China
| | - Donghao Chen
- Hangzhou Chance Pharmaceuticals, Hangzhou, China
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, School of Pharmacy, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| |
Collapse
|
2
|
Bass K, Farkas D, Hassan A, Bonasera S, Hindle M, Longest PW. High-Efficiency Dry Powder Aerosol Delivery to Children: Review and Application of New Technologies. JOURNAL OF AEROSOL SCIENCE 2021; 153:105692. [PMID: 33716317 PMCID: PMC7945982 DOI: 10.1016/j.jaerosci.2020.105692] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
While dry powder aerosol formulations offer a number of advantages, their use in children is often limited due to poor lung delivery efficiency and difficulties with consistent dry powder inhaler (DPI) usage. Both of these challenges can be attributed to the typical use of adult devices in pediatric subjects and a lack of pediatric-specific DPI development. In contrast, a number of technologies have recently been developed or progressed that can substantially improve the efficiency and reproducibility of DPI use in children including: (i) nose-to-lung administration with small particles, (ii) active positive-pressure devices, (iii) structures to reduce turbulence and jet momentum, and (iv) highly dispersible excipient enhanced growth particle formulations. In this study, these technologies and their recent development are first reviewed in depth. A case study is then considered in which these technologies are simultaneously applied in order to enable the nose-to-lung administration of dry powder aerosol to children with cystic fibrosis (CF). Using a combination of computational fluid dynamics (CFD) analysis and realistic in vitro experiments, device performance, aerosol size increases and lung delivery efficiency are considered for pediatric-CF subjects in the age ranges of 2-3, 5-6 and 9-10 years old. Results indicate that a new 3D rod array structure significantly improves performance of a nasal cannula reducing interface loss by a factor of 1.5-fold and produces a device emitted mass median aerodynamic diameter (MMAD) of 1.67 μm. For all ages considered, approximately 70% of the loaded dose reaches the lower lung beyond the lobar bronchi. Moreover, significant and rapid size increase of the aerosol is observed beyond the larynx and illustrates the potential for targeting lower airway deposition. In conclusion, concurrent CFD and realistic in vitro analysis indicates that a combination of multiple new technologies can be implemented to overcome obstacles that currently limit the use of DPIs in children as young as two years of age.
Collapse
Affiliation(s)
- Karl Bass
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA
| | - Dale Farkas
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA
| | - Amr Hassan
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| | - Serena Bonasera
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| | - P. Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| |
Collapse
|
3
|
Advancement of a Positive-Pressure Dry Powder Inhaler for Children: Use of a Vertical Aerosolization Chamber and Three-Dimensional Rod Array Interface. Pharm Res 2020; 37:177. [PMID: 32862295 DOI: 10.1007/s11095-020-02889-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 07/22/2020] [Indexed: 12/18/2022]
Abstract
PURPOSE Available dry powder inhalers (DPIs) have very poor lung delivery efficiencies in children. The objective of this study was to advance and experimentally test a positive-pressure air-jet DPI for children based on the use of a vertical aerosolization chamber and new patient interfaces that contain a three-dimensional (3D) rod array structure. METHODS Aerosolization performance of different air-jet DPI designs was first evaluated based on a 10 mg powder fill mass of a spray-dried excipient enhanced growth (EEG) formulation. Devices were actuated with positive pressure using flow rate (10-20 L/min) and inhaled volume (750 ml) conditions consistent with a 5-year-old child. Devices with best performance were connected to different mouthpiece designs to determine the effect on aerosolization and tested for aerosol penetration through a realistic pediatric in vitro mouth-throat model. RESULTS Use of the new vertical aerosolization chamber resulted in high quality aerosol formation. Inclusion of a 3D rod array structure in the mouthpiece further reduced aerosol size by approximately 20% compared to conditions without a rod array, and effectively dissipated the turbulent jet leaving the device. Best case device and mouthpiece combinations produced < 2% mouth-throat depositional loss and > 70% lung delivery efficiency based on loaded dose. CONCLUSIONS In conclusion, use of a 3D rod array in the MP of a positive-pressure air-jet DPI was found to reduce aerosol size by 20%, not significantly increase MP depositional loss, reduce mouth-throat deposition by 6.4-fold and enable lung delivery efficiency as high as 73.4% of loaded dose based on pediatric test conditions.
Collapse
|
4
|
Farkas D, Hindle M, Bonasera S, Bass K, Longest W. Development of an Inline Dry Powder Inhaler for Oral or Trans-Nasal Aerosol Administration to Children. J Aerosol Med Pulm Drug Deliv 2019; 33:83-98. [PMID: 31464559 DOI: 10.1089/jamp.2019.1540] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Background: Dry powder inhalers (DPIs) offer a number of advantages, such as rapid delivery of high-dose inhaled medications; however, DPI use in children is often avoided due to low lung delivery efficiency and difficulty in operating the device. The objective of this study was to develop a high-efficiency inline DPI for administering aerosol therapy to children with the option of using either an oral or trans-nasal approach. Methods: An inline DPI was developed that consisted of hollow inlet and outlet capillaries, a powder chamber, and a nasal or oral interface. A ventilation bag or compressed air was used to actuate the device and simultaneously provide a full deep inspiration consistent with a 5-year-old child. The powder chamber was partially filled with a model spray-dried excipient enhanced growth powder formulation with a mass of 10 mg. Device aerosolization was characterized with cascade impaction, and aerosol transmissions through oral and nasal in vitro models were assessed. Results: Best device performance was achieved when all actuation air passed through the powder chamber (no bypass flow) resulting in an aerosol mean mass median aerodynamic diameter (MMAD) <1.75 μm and a fine particle fraction (<5 μm) ≥90% based on emitted dose. Actuation with the ventilation bag enabled lung delivery efficiency through the nasal and oral interfaces to a tracheal filter of 60% or greater, based on loaded dose. In both oral and nose-to-lung (N2L) administrations, extrathoracic depositional losses were <10%. Conclusion: In conclusion, this study has proposed and initially developed an efficient inline DPI for delivering spray-dried formulations to children using positive pressure operation. Actuation of the device with positive pressure enabled effective N2L aerosol administration with a DPI, which may be beneficial for subjects who are too young to use a mouthpiece or to simultaneously treat the nasal and lung airways of older children.
Collapse
Affiliation(s)
- Dale Farkas
- Department of Mechanical and Nuclear Engineering and Virginia Commonwealth University, Richmond, Virginia
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Serena Bonasera
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Karl Bass
- Department of Mechanical and Nuclear Engineering and Virginia Commonwealth University, Richmond, Virginia
| | - Worth Longest
- Department of Mechanical and Nuclear Engineering and Virginia Commonwealth University, Richmond, Virginia.,Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| |
Collapse
|
5
|
Farkas D, Hindle M, Longest PW. Efficient Nose-to-Lung Aerosol Delivery with an Inline DPI Requiring Low Actuation Air Volume. Pharm Res 2018; 35:194. [PMID: 30132207 DOI: 10.1007/s11095-018-2473-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Accepted: 08/03/2018] [Indexed: 11/28/2022]
Abstract
PURPOSE To demonstrate efficient aerosol delivery through an in vitro nasal model using a dry powder inhaler (DPI) requiring low actuation air volumes (LV) applied during low-flow nasal cannula (LFNC) therapy. METHODS A previously developed LV-DPI was connected to a LFNC system with 4 mm diameter tubing. System connections and the nasal cannula interface were replaced with streamlined components. To simulate nasal respiration, an in vitro nasal model was connected to a downstream lung simulator that produced either passive or deep nasal respiration. Performance of a commercial mesh nebulizer system was also considered. RESULTS For the optimized system, steady state cannula emitted dose was 75% of the capsule loaded dose. With cyclic nasal breathing, delivery efficiency to the tracheal filter was 53-55% of the loaded dose, which was just under the design target of 60%. Compared with a commercially available mesh nebulizer, the optimal LV-DPI was 40-fold more efficient and 150 times faster in terms of delivering aerosol to the lungs. CONCLUSIONS The optimized LV-DPI system is capable of high efficiency lung delivery of powder aerosols through a challenging nasal cannula interface.
Collapse
Affiliation(s)
- Dale Farkas
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015 Richmond, Virginia, 23284-3015, USA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University Richmond, Virginia, USA
| | - P Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015 Richmond, Virginia, 23284-3015, USA. .,Department of Pharmaceutics, Virginia Commonwealth University Richmond, Virginia, USA.
| |
Collapse
|
6
|
Application of an inline dry powder inhaler to deliver high dose pharmaceutical aerosols during low flow nasal cannula therapy. Int J Pharm 2018; 546:1-9. [PMID: 29733972 DOI: 10.1016/j.ijpharm.2018.05.011] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Revised: 04/30/2018] [Accepted: 05/04/2018] [Indexed: 11/21/2022]
Abstract
Inline dry powder inhalers (DPIs) offer a potentially effective option to deliver high dose inhaled medications simultaneously with mechanical ventilation. The objective of this study was to develop an inline DPI that is actuated using a low volume of air (LV-DPI) to efficiently deliver pharmaceutical aerosols during low flow nasal cannula (LFNC) therapy. A characteristic feature of the new inline LV-DPIs was the use of hollow capillary tubes that both pierced the capsule and provided a pathway for inlet air and exiting aerosol. Aerosolization characteristics, LFNC depositional losses and emitted dose (ED) were determined using 10 mg powder masses of a small-particle excipient enhanced growth (EEG) formulation. While increasing the number of inlet capillaries from one to three did not improve performance, retracting the inlet and outlet capillaries did improve ED by over 30%. It was theorized that high quality performance requires both high turbulent energy to deaggregate the powder and high wall shear stresses to minimize capsule retention. Best case performance included a device ED of approximately 85% (of loaded dose) and device emitted mass median aerodynamic diameter of 1.77 µm. Maximum ED through the LFNC system and small diameter (4 mm) nasal cannula was approximately 65% of the loaded dose. Potential applications of this device include the delivery of high dose inhaled medications such as surfactants, antibiotics, mucolytics, and anti-inflammatories.
Collapse
|
7
|
Kadrichu N, Daniher D. Improvement of an In Vitro Model to Assess Delivered Dose and Particle Size for a Vibrating Mesh Nebulizer During Mechanical Ventilation. J Aerosol Med Pulm Drug Deliv 2018; 31:94-102. [DOI: 10.1089/jamp.2017.1372] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|