1
|
Bosch-Rué E, Zhang Q, Truskey GA, Olmos Buitrago J, M Bosch B, Pérez RA. Development of small tissue engineered blood vessels and their clinical and research applications. Biofabrication 2025; 17:032005. [PMID: 40341214 DOI: 10.1088/1758-5090/add626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Accepted: 05/08/2025] [Indexed: 05/10/2025]
Abstract
Since the first tissue engineered blood vessel (TEBV) was developed, different approaches, biomaterial scaffolds and cell sources have been used to obtain an engineered vessel as much similar as native vessels in terms of structure, functionality and mechanical properties. At the same time, diverse needs to obtain a functional TEBV have emerged, such as for blood vessel replacement for cardiovascular diseases (CVDs) to be used as artery bypass, to vascularize tissue engineered constructs, or even to model vascular diseases or drug testing. In this review, after briefly describing the native structure and function of arteries, we will give an overview of different biomaterials, cells and methods that have been used during the last years for the development of small TEBV (1-6 mm diameter). The importance of perfusing the TEBV to acquire functionality and maturation will be also discussed. Finally, we will center the review on TEBV applications beyond their use as vascular graft for CVDs.
Collapse
Affiliation(s)
- Elia Bosch-Rué
- Bioengineering Institute of Technology (BIT), Universitat Internacional de Catalunya (UIC), Sant Cugat del Vallès, 08195 Barcelona, Spain
- Bioengineering Department, Universitat Internacional de Catalunya (UIC), Sant Cugat del Vallès, 08195 Barcelona, Spain
| | - Qiao Zhang
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, United States of America
| | - George A Truskey
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, United States of America
| | - Jenifer Olmos Buitrago
- Bioengineering Institute of Technology (BIT), Universitat Internacional de Catalunya (UIC), Sant Cugat del Vallès, 08195 Barcelona, Spain
- Bioengineering Department, Universitat Internacional de Catalunya (UIC), Sant Cugat del Vallès, 08195 Barcelona, Spain
| | - Begoña M Bosch
- Bioengineering Institute of Technology (BIT), Universitat Internacional de Catalunya (UIC), Sant Cugat del Vallès, 08195 Barcelona, Spain
- Bioengineering Department, Universitat Internacional de Catalunya (UIC), Sant Cugat del Vallès, 08195 Barcelona, Spain
| | - Román A Pérez
- Bioengineering Institute of Technology (BIT), Universitat Internacional de Catalunya (UIC), Sant Cugat del Vallès, 08195 Barcelona, Spain
- Bioengineering Department, Universitat Internacional de Catalunya (UIC), Sant Cugat del Vallès, 08195 Barcelona, Spain
| |
Collapse
|
2
|
Hayam R, Hamias S, Skitel Moshe M, Davidov T, Yen FC, Baruch L, Machluf M. Porcine Bone Extracellular Matrix Hydrogel as a Promising Graft for Bone Regeneration. Gels 2025; 11:173. [PMID: 40136879 PMCID: PMC11942433 DOI: 10.3390/gels11030173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2025] [Revised: 02/18/2025] [Accepted: 02/24/2025] [Indexed: 03/27/2025] Open
Abstract
Bone defects resulting from trauma, tumors, or congenital conditions pose significant challenges for natural healing and often require grafting solutions. While autografts remain the gold standard, their limitations, such as restricted availability and donor site complications, underscore the need for alternative approaches. The present research investigates the potential of porcine-derived bone extracellular matrix (pbECM) hydrogel as a highly promising bioactive scaffold for bone regeneration, comparing it to the human-derived bECM (hbECM). Porcine and human cancellous bones were decellularized and characterized in terms of their composition and structure. Further, the ECMs were processed into hydrogels, and their rheological properties and cytocompatibility were studied in vitro while their biocompatibility was studied in vivo using a mouse model. The potential of the pbECM hydrogel as a bone graft was evaluated in vivo using a rat femoral defect model. Our results demonstrated the excellent preservation of essential ECM components in both the pbECM and hbECM with more than 90% collagen out of all proteins. Rheological analyses revealed the superior mechanical properties of the pbECM hydrogel compared to the hbECM, with an approximately 10-fold higher storage modulus and a significantly later deformation point. These stronger gel properties of the pbECM were attributed to the higher content of structural proteins and residual minerals. Both the pbECM and hbECM effectively supported mesenchymal stem cell adhesion, viability, and proliferation, achieving a 20-fold increase in cell number within 10 days and highlighting their strong bioactive potential. In vivo, pbECM hydrogels elicited a minimal immunogenic response. Most importantly, when implanted in a rat femoral defect model, pbECM hydrogel had significantly enhanced bone regeneration through graft integration, stem cell recruitment, and differentiation. New bone formation was observed at an average of 50% of the defect volume, outperforming the commercial demineralized bone matrix (DBM), in which the new bone filled only 35% of the defect volume. These results position pbECM hydrogel as a highly effective and biocompatible scaffold for bone tissue engineering, offering a promising alternative to traditional grafting methods and paving the way for future clinical applications in bone repair.
Collapse
Affiliation(s)
- Rotem Hayam
- Faculty of Biotechnology & Food Engineering, Technion—Israel Institute of Technology (IIT), Haifa 3200003, Israel; (R.H.); (S.H.); (T.D.); (F.-C.Y.); (L.B.)
| | - Shani Hamias
- Faculty of Biotechnology & Food Engineering, Technion—Israel Institute of Technology (IIT), Haifa 3200003, Israel; (R.H.); (S.H.); (T.D.); (F.-C.Y.); (L.B.)
| | - Michal Skitel Moshe
- The Interdisciplinary Program for Biotechnology, Technion—Israel Institute of Technology, Haifa 3200003, Israel;
| | - Tzila Davidov
- Faculty of Biotechnology & Food Engineering, Technion—Israel Institute of Technology (IIT), Haifa 3200003, Israel; (R.H.); (S.H.); (T.D.); (F.-C.Y.); (L.B.)
| | - Feng-Chun Yen
- Faculty of Biotechnology & Food Engineering, Technion—Israel Institute of Technology (IIT), Haifa 3200003, Israel; (R.H.); (S.H.); (T.D.); (F.-C.Y.); (L.B.)
| | - Limor Baruch
- Faculty of Biotechnology & Food Engineering, Technion—Israel Institute of Technology (IIT), Haifa 3200003, Israel; (R.H.); (S.H.); (T.D.); (F.-C.Y.); (L.B.)
| | - Marcelle Machluf
- Faculty of Biotechnology & Food Engineering, Technion—Israel Institute of Technology (IIT), Haifa 3200003, Israel; (R.H.); (S.H.); (T.D.); (F.-C.Y.); (L.B.)
| |
Collapse
|
3
|
Wang T, Liao S, Lu P, He Z, Cheng S, Wang T, Cheng Z, An Y, Wang M, Shu C. Improved porosity promotes reendothelialization and smooth muscle remodeling in decellularized tissue-engineered vascular grafts. Mater Today Bio 2025; 30:101402. [PMID: 39790489 PMCID: PMC11714392 DOI: 10.1016/j.mtbio.2024.101402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2024] [Revised: 12/06/2024] [Accepted: 12/10/2024] [Indexed: 01/12/2025] Open
Abstract
Decellularized tissue-engineered vascular grafts (dTEVGs) exhibit superior biocompatibility, anti-infection properties and repair potential, contributing to better patency and making them a more ideal choice for arteriovenous grafts (AVGs) in hemodialysis compared to chemically synthesized grafts. However, the unsatisfactory reendothelialization and smooth muscle remodeling of current dTEVGs limit their advantages. In this study, we investigated the use of elastase to improve the porosity of elastic fiber layers in dTEVGs, aiming to promote cell infiltration and achieve superior reendothelialization and smooth muscle remodeling. Our findings revealed that elastase treatment induced scattered cracks and holes in the elastic fiber layers of dTEVGs. Porous dTEVGs demonstrated increased cell infiltration in rat subcutaneous tissue. In the rat AVG models, mildly elastase-treated dTEVGs significantly improved cell infiltration and graft remodeling, including adequate smooth muscle cell (SMC) repopulation, impressive reendothelization and regeneration of the extracellular matrix, without stenosis, dilation or disintegration of the grafts. This study demonstrates that porous dTEVGs promote reendothelization, smooth muscle remodeling and extracellular matrix regeneration while retaining a stable graft structure, enhancing durability and puncture resistance in hemodialysis.
Collapse
Affiliation(s)
- Tun Wang
- Department of Vascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, China
- Institute of Vascular Diseases, Central South University, Changsha, 410011, China
| | - Sheng Liao
- Department of Vascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, China
- Institute of Vascular Diseases, Central South University, Changsha, 410011, China
| | - Peng Lu
- Department of Vascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, China
- Institute of Vascular Diseases, Central South University, Changsha, 410011, China
| | - Zhenyu He
- Department of Vascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, China
- Institute of Vascular Diseases, Central South University, Changsha, 410011, China
| | - Siyuan Cheng
- Department of Vascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, China
- Institute of Vascular Diseases, Central South University, Changsha, 410011, China
| | - Tianjian Wang
- Department of Vascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, China
- Institute of Vascular Diseases, Central South University, Changsha, 410011, China
| | - Zibo Cheng
- Department of Vascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, China
- Institute of Vascular Diseases, Central South University, Changsha, 410011, China
| | - Yangyang An
- Department of Vascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, China
- Institute of Vascular Diseases, Central South University, Changsha, 410011, China
| | - Mo Wang
- Department of Vascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, China
- Institute of Vascular Diseases, Central South University, Changsha, 410011, China
| | - Chang Shu
- Department of Vascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, China
- Institute of Vascular Diseases, Central South University, Changsha, 410011, China
- Center of Vascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100037, China
| |
Collapse
|
4
|
Lorentz KL, Marini AX, Bruk LA, Gupta P, Mandal BB, DiLeo MV, Weinbaum JS, Little SR, Vorp DA. Mesenchymal Stem Cell-Conditioned Media-Loaded Microparticles Enhance Acute Patency in Silk-Based Vascular Grafts. Bioengineering (Basel) 2024; 11:947. [PMID: 39329689 PMCID: PMC11428691 DOI: 10.3390/bioengineering11090947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Revised: 08/10/2024] [Accepted: 09/10/2024] [Indexed: 09/28/2024] Open
Abstract
Coronary artery disease leads to over 360,000 deaths annually in the United States, and off-the-shelf bypass graft options are currently limited and/or have high failure rates. Tissue-engineered vascular grafts (TEVGs) present an attractive option, though the promising mesenchymal stem cell (MSC)-based implants face uncertain regulatory pathways. In this study, "artificial MSCs" (ArtMSCs) were fabricated by encapsulating MSC-conditioned media (CM) in poly(lactic-co-glycolic acid) microparticles. ArtMSCs and control microparticles (Blank-MPs) were incubated over 7 days to assess the release of total protein and the vascular endothelial growth factor (VEGF-A); releasates were also assessed for cytotoxicity and promotion of smooth muscle cell (SMC) proliferation. Each MP type was loaded in previously published "lyogel" silk scaffolds and implanted as interposition grafts in Lewis rats for 1 or 8 weeks. Explanted grafts were assessed for patency and cell content. ArtMSCs had a burst release of protein and VEGF-A. CM increased proliferation in SMCs, but not after encapsulation. TEVG explants after 1 week had significantly higher patency rates with ArtMSCs compared to Blank-MPs, but similar to unseeded lyogel grafts. ArtMSC explants had lower numbers of infiltrating macrophages compared to Blank-MP explants, suggesting a modulation of inflammatory response by the ArtMSCs. TEVG explants after 8 weeks showed no significant difference in patency among the three groups. The ArtMSC explants showed higher numbers of SMCs and endothelial cells within the neotissue layer of the graft compared to Blank-MP explants. In sum, while the ArtMSCs had positive effects acutely, efficacy was lost in the longer term; therefore, further optimization is needed.
Collapse
Affiliation(s)
- Katherine L Lorentz
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261, USA
| | - Ande X Marini
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261, USA
| | - Liza A Bruk
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261, USA
| | - Prerak Gupta
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261, USA
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| | - Biman B Mandal
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
- Jyoti and Bhupat Mehta School of Health Sciences and Technology, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| | - Morgan V DiLeo
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261, USA
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA 15213, USA
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219, USA
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, PA 15261, USA
- Clinical & Translational Sciences Institute, University of Pittsburgh, Pittsburgh, PA 15213, USA
| | - Justin S Weinbaum
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261, USA
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219, USA
- Department of Pathology, University of Pittsburgh, Pittsburgh, PA 15260, USA
| | - Steven R Little
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261, USA
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219, USA
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, PA 15261, USA
- Department of Pathology, University of Pittsburgh, Pittsburgh, PA 15260, USA
- Department of Immunology, University of Pittsburgh, Pittsburgh, PA 15213, USA
- Department of Pharmaceutical Sciences, University of Pittsburgh, Pittsburgh, PA 15213, USA
| | - David A Vorp
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261, USA
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219, USA
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, PA 15261, USA
- Clinical & Translational Sciences Institute, University of Pittsburgh, Pittsburgh, PA 15213, USA
- Department of Surgery, University of Pittsburgh, Pittsburgh, PA 15213, USA
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, PA 15261, USA
- Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, PA 15213, USA
- Magee Women's Research Institute, Pittsburgh, PA 15213, USA
| |
Collapse
|
5
|
Kang C, Yang H. The journey of decellularized vessel: from laboratory to operating room. Front Bioeng Biotechnol 2024; 12:1413518. [PMID: 38983603 PMCID: PMC11231200 DOI: 10.3389/fbioe.2024.1413518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2024] [Accepted: 06/05/2024] [Indexed: 07/11/2024] Open
Abstract
Over the past few decades, there has been a remarkable advancement in the field of transplantation. But the shortage of donors is still an urgent problem that requires immediate attention. As with xenotransplantation, bioengineered organs are promising solutions to the current shortage situation. And decellularization is a unique technology in organ-bioengineering. However, at present, there is no unified decellularization method for different tissues, and there is no gold-standard for evaluating decellularization efficiency. Meanwhile, recellularization, re-endothelialization and modification are needed to form transplantable organs. With this mind, we can start with decellularization and re-endothelialization or modification of small blood vessels, which would serve to address the shortage of small-diameter vessels while simultaneously gathering the requisite data and inspiration for further recellularization of the whole organ-scale vascular network. In this review, we collect the related experiments of decellularization and post-decellularization approaches of small vessels in recent years. Subsequently, we summarize the experience in relation to the decellularization and post-decellularization combinations, and put forward obstacle we face and possible solutions.
Collapse
Affiliation(s)
- Chenbin Kang
- School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Hongji Yang
- Organ Transplant Center, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China
- Clinical Immunology Translational Medicine Key Laboratory of Sichuan Province and Organ Transplantation Center, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China
| |
Collapse
|
6
|
Jia H, Chang Y, Song J. The pig as an optimal animal model for cardiovascular research. Lab Anim (NY) 2024; 53:136-147. [PMID: 38773343 DOI: 10.1038/s41684-024-01377-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 04/22/2024] [Indexed: 05/23/2024]
Abstract
Cardiovascular disease is a worldwide health problem and a leading cause of morbidity and mortality. Preclinical cardiovascular research using animals is needed to explore potential targets and therapeutic options. Compared with rodents, pigs have many advantages, with their anatomy, physiology, metabolism and immune system being more similar to humans. Here we present an overview of the available pig models for cardiovascular diseases, discuss their advantages over other models and propose the concept of standardized models to improve translation to the clinical setting and control research costs.
Collapse
Affiliation(s)
- Hao Jia
- Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Centre, National Centre for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yuan Chang
- Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Centre, National Centre for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jiangping Song
- Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Centre, National Centre for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
- Sanya Institute of China Agricultural University, Sanya, China.
| |
Collapse
|
7
|
Ding H, Hou X, Gao Z, Guo Y, Liao B, Wan J. Challenges and Strategies for Endothelializing Decellularized Small-Diameter Tissue-Engineered Vessel Grafts. Adv Healthc Mater 2024; 13:e2304432. [PMID: 38462702 DOI: 10.1002/adhm.202304432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 02/26/2024] [Indexed: 03/12/2024]
Abstract
Vascular diseases are the leading cause of ischemic necrosis in tissues and organs, necessitating using vascular grafts to restore blood supply. Currently, small vessels for coronary artery bypass grafts are unavailable in clinical settings. Decellularized small-diameter tissue-engineered vessel grafts (SD-TEVGs) hold significant potential. However, they face challenges, as simple implantation of decellularized SD-TEVGs in animals leads to thrombosis and calcification due to incomplete endothelialization. Consequently, research and development focus has shifted toward enhancing the endothelialization process of decellularized SD-TEVGs. This paper reviews preclinical studies involving decellularized SD-TEVGs, highlighting different strategies and their advantages and disadvantages for achieving rapid endothelialization of these vascular grafts. Methods are analyzed to improve the process while addressing potential shortcomings. This paper aims to contribute to the future commercial viability of decellularized SD-TEVGs.
Collapse
Affiliation(s)
- Heng Ding
- Department of Cardiovascular Surgery, The Affiliated Hospital, Southwest Medical University, Metabolic Vascular Diseases Key Laboratory of Sichuan Province, Key Laboratory of cardiovascular remodeling and dysfunction, Luzhou, Sichuan, 646000, China
- Nanjing Medical University, Nanjing, 211166, P. R. China
| | - Xiaojie Hou
- Department of Cardiovascular Surgery and Cardiovascular Surgery Research Laboratory, West China Hospital, Sichuan University, Chengdu, Sichuan, 610041, China
| | - Zhen Gao
- Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, 100069, China
| | - Yingqiang Guo
- Department of Cardiovascular Surgery and Cardiovascular Surgery Research Laboratory, West China Hospital, Sichuan University, Chengdu, Sichuan, 610041, China
| | - Bin Liao
- Department of Cardiovascular Surgery, The Affiliated Hospital, Southwest Medical University, Metabolic Vascular Diseases Key Laboratory of Sichuan Province, Key Laboratory of cardiovascular remodeling and dysfunction, Luzhou, Sichuan, 646000, China
- Key Laboratory of Medical Electrophysiology, Ministry of Education & Medical Electrophysiological Key Laboratory of Sichuan Province, (Collaborative Innovation Center for Prevention of Cardiovascular Diseases), Institute of Cardiovascular Research, Southwest Medical University, Luzhou, Sichuan, 646000, China
| | - Juyi Wan
- Department of Cardiovascular Surgery, The Affiliated Hospital, Southwest Medical University, Metabolic Vascular Diseases Key Laboratory of Sichuan Province, Key Laboratory of cardiovascular remodeling and dysfunction, Luzhou, Sichuan, 646000, China
- Key Laboratory of Medical Electrophysiology, Ministry of Education & Medical Electrophysiological Key Laboratory of Sichuan Province, (Collaborative Innovation Center for Prevention of Cardiovascular Diseases), Institute of Cardiovascular Research, Southwest Medical University, Luzhou, Sichuan, 646000, China
| |
Collapse
|
8
|
Yan H, Cheng Q, Si J, Wang S, Wan Y, Kong X, Wang T, Zheng W, Rafique M, Li X, He J, Midgley AC, Zhu Y, Wang K, Kong D. Functionalization of in vivo tissue-engineered living biotubes enhance patency and endothelization without the requirement of systemic anticoagulant administration. Bioact Mater 2023; 26:292-305. [PMID: 36950151 PMCID: PMC10027480 DOI: 10.1016/j.bioactmat.2023.03.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 02/19/2023] [Accepted: 03/05/2023] [Indexed: 03/18/2023] Open
Abstract
Vascular regeneration and patency maintenance, without anticoagulant administration, represent key developmental trends to enhance small-diameter vascular grafts (SDVG) performance. In vivo engineered autologous biotubes have emerged as SDVG candidates with pro-regenerative properties. However, mechanical failure coupled with thrombus formation hinder translational prospects of biotubes as SDVGs. Previously fabricated poly(ε-caprolactone) skeleton-reinforced biotubes (PBs) circumvented mechanical issues and achieved vascular regeneration, but orally administered anticoagulants were required. Here, highly efficient and biocompatible functional modifications were introduced to living cells on PB lumens. The 1,2-dimyristoyl-sn-glycero-3-phosphoethanolamine-N-methoxy (DMPE)-PEG-conjugated anti-coagulant bivalirudin (DPB) and DMPE-PEG-conjugated endothelial progenitor cell (EPC)-binding TPS-peptide (DPT) modifications possessed functionality conducive to promoting vascular graft patency. Co-modification of DPB and DPT swiftly attained luminal saturation without influencing cell viability. DPB repellent of non-specific proteins, DPB inhibition of thrombus formation, and DPB protection against functional masking of DPT's EPC-capture by blood components, which promoted patency and rapid endothelialization in rat and canine artery implantation models without anticoagulant administration. This strategy offers a safe, facile, and fast technical approach to convey additional functionalization to living cells within tissue-engineered constructs.
Collapse
Affiliation(s)
- Hongyu Yan
- Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
- Department of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 200233, China
| | - Quhan Cheng
- Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Jianghua Si
- Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Songdi Wang
- Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Ye Wan
- Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Xin Kong
- Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Ting Wang
- Tianjin Key Laboratory of Urban Transport Emission Research, College of Environmental Science and Engineering, Nankai University, Tianjin, 300071, China
| | - Wenting Zheng
- State Key Laboratory of Experimental Hematology, National Clinical Research Center for Blood Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, 300020, China
| | - Muhammad Rafique
- Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Xiaofeng Li
- Department of Vascular Surgery, Tianjin First Central Hospital, Nankai University, Tianjin, 300192, China
| | - Ju He
- Department of Vascular Surgery, Tianjin First Central Hospital, Nankai University, Tianjin, 300192, China
| | - Adam C. Midgley
- Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
- Corresponding author.
| | - Yi Zhu
- Department of Physiology and Pathophysiology, Tianjin Medical University, Tianjin, 300070, China
| | - Kai Wang
- Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
- Corresponding author.
| | - Deling Kong
- Key Laboratory of Bioactive Materials for the Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| |
Collapse
|
9
|
Afzal Z, Huguet EL. Bioengineering liver tissue by repopulation of decellularised scaffolds. World J Hepatol 2023; 15:151-179. [PMID: 36926238 PMCID: PMC10011915 DOI: 10.4254/wjh.v15.i2.151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 11/22/2022] [Accepted: 02/15/2023] [Indexed: 02/24/2023] Open
Abstract
Liver transplantation is the only curative therapy for end stage liver disease, but is limited by the organ shortage, and is associated with the adverse consequences of immunosuppression. Repopulation of decellularised whole organ scaffolds with appropriate cells of recipient origin offers a theoretically attractive solution, allowing reliable and timely organ sourcing without the need for immunosuppression. Decellularisation methodologies vary widely but seek to address the conflicting objectives of removing the cellular component of tissues whilst keeping the 3D structure of the extra-cellular matrix intact, as well as retaining the instructive cell fate determining biochemicals contained therein. Liver scaffold recellularisation has progressed from small rodent in vitro studies to large animal in vivo perfusion models, using a wide range of cell types including primary cells, cell lines, foetal stem cells, and induced pluripotent stem cells. Within these models, a limited but measurable degree of physiologically significant hepatocyte function has been reported with demonstrable ammonia metabolism in vivo. Biliary repopulation and function have been restricted by challenges relating to the culture and propagations of cholangiocytes, though advances in organoid culture may help address this. Hepatic vasculature repopulation has enabled sustainable blood perfusion in vivo, but with cell types that would limit clinical applications, and which have not been shown to have the specific functions of liver sinusoidal endothelial cells. Minority cell groups such as Kupffer cells and stellate cells have not been repopulated. Bioengineering by repopulation of decellularised scaffolds has significantly progressed, but there remain significant experimental challenges to be addressed before therapeutic applications may be envisaged.
Collapse
Affiliation(s)
- Zeeshan Afzal
- Department of Surgery, Addenbrookes Hospital, NIHR Comprehensive Biomedical Research and Academic Health Sciences Centre; Cambridge University Hospitals NHS Foundation Trust, Cambridge CB2 0QQ, United Kingdom
| | - Emmanuel Laurent Huguet
- Department of Surgery, Addenbrookes Hospital, NIHR Comprehensive Biomedical Research and Academic Health Sciences Centre; Cambridge University Hospitals NHS Foundation Trust, Cambridge CB2 0QQ, United Kingdom
| |
Collapse
|
10
|
Tan W, Boodagh P, Selvakumar PP, Keyser S. Strategies to counteract adverse remodeling of vascular graft: A 3D view of current graft innovations. Front Bioeng Biotechnol 2023; 10:1097334. [PMID: 36704297 PMCID: PMC9871289 DOI: 10.3389/fbioe.2022.1097334] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Accepted: 12/23/2022] [Indexed: 01/11/2023] Open
Abstract
Vascular grafts are widely used for vascular surgeries, to bypass a diseased artery or function as a vascular access for hemodialysis. Bioengineered or tissue-engineered vascular grafts have long been envisioned to take the place of bioinert synthetic grafts and even vein grafts under certain clinical circumstances. However, host responses to a graft device induce adverse remodeling, to varied degrees depending on the graft property and host's developmental and health conditions. This in turn leads to invention or failure. Herein, we have mapped out the relationship between the design constraints and outcomes for vascular grafts, by analyzing impairment factors involved in the adverse graft remodeling. Strategies to tackle these impairment factors and counteract adverse healing are then summarized by outlining the research landscape of graft innovations in three dimensions-cell technology, scaffold technology and graft translation. Such a comprehensive view of cell and scaffold technological innovations in the translational context may benefit the future advancements in vascular grafts. From this perspective, we conclude the review with recommendations for future design endeavors.
Collapse
Affiliation(s)
- Wei Tan
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, United States,*Correspondence: Wei Tan,
| | - Parnaz Boodagh
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, United States
| | | | - Sean Keyser
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, United States
| |
Collapse
|
11
|
Perdreau E, Jalal Z, Walton RD, Sigler M, Cochet H, Naulin J, Quesson B, Bernus O, Thambo JB. Assessment of Nit-Occlud atrial septal defect occluder device healing process using micro-computed tomography imaging. PLoS One 2023; 18:e0284471. [PMID: 37093832 PMCID: PMC10124873 DOI: 10.1371/journal.pone.0284471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Accepted: 04/01/2023] [Indexed: 04/25/2023] Open
Abstract
After percutaneous implantation of a cardiac occluder, a complex healing process leads to the device coverage within several months. An incomplete device coverage increases the risk of device related complications such as thrombosis or endocarditis. We aimed to assess the device coverage process of atrial septal defect (ASD) occluders in a chronic sheep model using micro-computed tomography (micro-CT). After percutaneous creation of an ASD, 8 ewes were implanted with a 16-mm Nit-Occlud ASD-R occluder (PFM medical, Cologne, Germany) and were followed for 1 month (N = 3) and 3 months (N = 5). After heart explant, the device coverage was assessed using micro-CT (resolution of 41.7 μm) and was compared to histological analysis. The micro-CT image reconstruction was performed in 2D and 3D allowing measurement of the coverage thickness and surface for each device. Macroscopic assessment of devices showed that the coverage was complete for the left-side disk in all cases. Yet incomplete coverage of the right-side disk was observed in 5 of the 8 cases. 2D and 3D micro-CT analysis allowed an accurate evaluation of device coverage of each disk and was overall well correlated to histology sections. Surface calculation from micro-CT images of the 8 cases showed that the median surface of coverage was 93±8% for the left-side disk and 55±31% for the right-side disk. The assessment of tissue reactions, including endothelialisation, after implantation of an ASD occluder can rely on in vitro micro-CT analysis. The translation to clinical practice is challenging but the potential for individual follow-up is shown, to avoid thrombotic or infective complications.
Collapse
Affiliation(s)
- Elodie Perdreau
- Electrophysiology and Heart Modeling Institute, IHU Liryc, Fondation Bordeaux Université, Pessac-Bordeaux, France
- U1045, Centre de recherche Cardio-Thoracique de Bordeaux, Université de Bordeaux, Bordeaux, France
- U1045, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France
| | - Zakaria Jalal
- Electrophysiology and Heart Modeling Institute, IHU Liryc, Fondation Bordeaux Université, Pessac-Bordeaux, France
- U1045, Centre de recherche Cardio-Thoracique de Bordeaux, Université de Bordeaux, Bordeaux, France
- U1045, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France
- Congenital and Pediatric Cardiology Unit, Bordeaux University Hospital, Pessac, France
| | - Richard D Walton
- Electrophysiology and Heart Modeling Institute, IHU Liryc, Fondation Bordeaux Université, Pessac-Bordeaux, France
- U1045, Centre de recherche Cardio-Thoracique de Bordeaux, Université de Bordeaux, Bordeaux, France
- U1045, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France
| | - Matthias Sigler
- Pediatric Cardiology and Intensive Care Medicine, Georg-August University Hospital, Göttingen, Germany
| | - Hubert Cochet
- Electrophysiology and Heart Modeling Institute, IHU Liryc, Fondation Bordeaux Université, Pessac-Bordeaux, France
- U1045, Centre de recherche Cardio-Thoracique de Bordeaux, Université de Bordeaux, Bordeaux, France
- U1045, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France
- Cardiothoracic Pole, Bordeaux University Hospital, Pessac, France
| | - Jérôme Naulin
- Electrophysiology and Heart Modeling Institute, IHU Liryc, Fondation Bordeaux Université, Pessac-Bordeaux, France
- U1045, Centre de recherche Cardio-Thoracique de Bordeaux, Université de Bordeaux, Bordeaux, France
- U1045, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France
| | - Bruno Quesson
- Electrophysiology and Heart Modeling Institute, IHU Liryc, Fondation Bordeaux Université, Pessac-Bordeaux, France
- U1045, Centre de recherche Cardio-Thoracique de Bordeaux, Université de Bordeaux, Bordeaux, France
- U1045, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France
| | - Olivier Bernus
- Electrophysiology and Heart Modeling Institute, IHU Liryc, Fondation Bordeaux Université, Pessac-Bordeaux, France
- U1045, Centre de recherche Cardio-Thoracique de Bordeaux, Université de Bordeaux, Bordeaux, France
- U1045, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France
| | - Jean-Benoît Thambo
- Electrophysiology and Heart Modeling Institute, IHU Liryc, Fondation Bordeaux Université, Pessac-Bordeaux, France
- U1045, Centre de recherche Cardio-Thoracique de Bordeaux, Université de Bordeaux, Bordeaux, France
- U1045, INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France
- Congenital and Pediatric Cardiology Unit, Bordeaux University Hospital, Pessac, France
| |
Collapse
|
12
|
Wong V, Gada S, Singh M, Merna N. The Development of Small-Caliber Vascular Grafts Using Human Umbilical Artery: An Evaluation of Methods. Tissue Eng Part C Methods 2023; 29:1-10. [PMID: 36322709 DOI: 10.1089/ten.tec.2022.0144] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Due to the prevalence of cardiovascular disease in the United States, small-caliber vascular grafts for coronary bypass surgery continue to be in high demand. Human umbilical arteries, an underutilized resource, were decellularized using zwitterionic (3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate [CHAPS]) and ionic (sodium dodecyl sulfate [SDS]) detergents and evaluated as potential vascular grafts. Vessels were tested for decellularization efficacy, mechanical integrity, and recellularization potential. Hematoxylin and eosin staining and DNA quantification revealed moderate to successful removal of cells in both conditions. While CHAPS-decellularized vessels displayed collagen structure most similar to intact tissue, both CHAPS- and SDS-decellularized vessels demonstrated burst pressures lower than that of intact tissue. Alcian Blue staining and sulfated glycosaminoglycan (sGAG) quantification indicated the preservation of sGAG content after both decellularization pathways. Both conditions were also capable of recellularization with human umbilical vein endothelial cells, and the use of a basic fibroblast growth factor treatment did not have a significant effect on the density of adhered cells after 5 days. Whole CHAPS-decellularized vessels were successfully recellularized. Additionally, an evaluation of the effects of freeze-thaw cycles was performed. In summary, human umbilical arteries present a promising alternative for small-caliber vascular grafts due to their high availability and ability to be decellularized and recellularized for safe and successful implantation. Impact Statement Coronary heart disease accounts for one of nine deaths in the United States each year. Bypass surgery has been shown to decrease the risk of heart attack; however, many patients do not have a suitable saphenous vein, which is required to redirect blood flow around their blocked arteries. In this study, we evaluate decellularized umbilical artery as a potential small-diameter vascular graft based on its mechanical properties and its recellularization potential.
Collapse
Affiliation(s)
- Vanessa Wong
- Bioengineering Program, Fred DeMatteis School of Engineering and Applied Science, Hofstra University, Hempstead, New York, USA
| | - Sheykha Gada
- Bioengineering Program, Fred DeMatteis School of Engineering and Applied Science, Hofstra University, Hempstead, New York, USA
| | - Melanie Singh
- Bioengineering Program, Fred DeMatteis School of Engineering and Applied Science, Hofstra University, Hempstead, New York, USA
| | - Nick Merna
- Bioengineering Program, Fred DeMatteis School of Engineering and Applied Science, Hofstra University, Hempstead, New York, USA
| |
Collapse
|
13
|
Jenndahl L, Österberg K, Bogestål Y, Simsa R, Gustafsson-Hedberg T, Stenlund P, Petronis S, Krona A, Fogelstrand P, Strehl R, Håkansson J. Personalized tissue-engineered arteries as vascular graft transplants: A safety study in sheep. Regen Ther 2022; 21:331-341. [PMID: 36110971 PMCID: PMC9463533 DOI: 10.1016/j.reth.2022.08.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 07/04/2022] [Accepted: 08/09/2022] [Indexed: 11/23/2022] Open
Abstract
Patients with cardiovascular disease often need replacement or bypass of a diseased blood vessel. With disadvantages of both autologous blood vessels and synthetic grafts, tissue engineering is emerging as a promising alternative of advanced therapy medicinal products for individualized blood vessels. By reconditioning of a decellularized blood vessel with the recipient’s own peripheral blood, we have been able to prevent rejection without using immunosuppressants and prime grafts for efficient recellularization in vivo. Recently, decellularized veins reconditioned with autologous peripheral blood were shown to be safe and functional in a porcine in vivo study as a potential alternative for vein grafting. In this study, personalized tissue engineered arteries (P-TEA) were developed using the same methodology and evaluated for safety in a sheep in vivo model of carotid artery transplantation. Five personalized arteries were transplanted to carotid arteries and analyzed for safety and patency as well as with histology after four months in vivo. All grafts were fully patent without any occlusion or stenosis. The tissue was well cellularized with a continuous endothelial cell layer covering the luminal surface, revascularized adventitia with capillaries and no sign of rejection or infection. In summary, the results indicate that P-TEA is safe to use and has potential as clinical grafts. Safety and functionality evaluation of a tissue engineered ATMP in a sheep model of carotid transplantation. Efficient cellularization of a personalized tissue engineered artery in vivo. Personalized tissue engineered artery fully patent after four months in vivo.
Collapse
Affiliation(s)
- Lachmi Jenndahl
- VERIGRAFT AB, Arvid Wallgrensbacke 20, 413 46, Göteborg, Sweden
| | - Klas Österberg
- Sahlgrenska Academy, Institution of Medicine, Department of Molecular and Clinical Medicine, Blå Stråket 5 B Wallenberg Laboratory, 41345 Gothenburg, Sweden
| | - Yalda Bogestål
- RISE Research Institutes of Sweden, Materials and Production, Brinellgatan 4, 504 62 Borås, Sweden
| | - Robin Simsa
- VERIGRAFT AB, Arvid Wallgrensbacke 20, 413 46, Göteborg, Sweden.,Department of Molecular and Clinical Medicine/Wallenberg Laboratory, University of Gothenburg and Sahlgrenska University Hospital, Gothenburg, Sweden
| | | | - Patrik Stenlund
- RISE Research Institutes of Sweden, Materials and Production, Brinellgatan 4, 504 62 Borås, Sweden
| | - Sarunas Petronis
- RISE Research Institutes of Sweden, Materials and Production, Brinellgatan 4, 504 62 Borås, Sweden
| | - Annika Krona
- RISE Research Institutes of Sweden, Agriculture and Food, Box 5401, 402 29 Gothenburg, Sweden
| | - Per Fogelstrand
- Department of Molecular and Clinical Medicine/Wallenberg Laboratory, University of Gothenburg and Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Raimund Strehl
- VERIGRAFT AB, Arvid Wallgrensbacke 20, 413 46, Göteborg, Sweden
| | - Joakim Håkansson
- RISE Research Institutes of Sweden, Materials and Production, Brinellgatan 4, 504 62 Borås, Sweden.,Gothenburg University, Department of Laboratory Medicine, Institute of Biomedicine, Gothenburg, Sweden
| |
Collapse
|
14
|
Wang X, Chan V, Corridon PR. Decellularized blood vessel development: Current state-of-the-art and future directions. Front Bioeng Biotechnol 2022; 10:951644. [PMID: 36003539 PMCID: PMC9394443 DOI: 10.3389/fbioe.2022.951644] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 07/14/2022] [Indexed: 12/31/2022] Open
Abstract
Vascular diseases contribute to intensive and irreversible damage, and current treatments include medications, rehabilitation, and surgical interventions. Often, these diseases require some form of vascular replacement therapy (VRT) to help patients overcome life-threatening conditions and traumatic injuries annually. Current VRTs rely on harvesting blood vessels from various regions of the body like the arms, legs, chest, and abdomen. However, these procedures also produce further complications like donor site morbidity. Such common comorbidities may lead to substantial pain, infections, decreased function, and additional reconstructive or cosmetic surgeries. Vascular tissue engineering technology promises to reduce or eliminate these issues, and the existing state-of-the-art approach is based on synthetic or natural polymer tubes aiming to mimic various types of blood vessel. Burgeoning decellularization techniques are considered as the most viable tissue engineering strategy to fill these gaps. This review discusses various approaches and the mechanisms behind decellularization techniques and outlines a simplified model for a replacement vascular unit. The current state-of-the-art method used to create decellularized vessel segments is identified. Also, perspectives on future directions to engineer small- (inner diameter >1 mm and <6 mm) to large-caliber (inner diameter >6 mm) vessel substitutes are presented.
Collapse
Affiliation(s)
- Xinyu Wang
- Biomedical Engineering and Healthcare Engineering Innovation Center, Khalifa University, Abu Dhabi, United Arab Emirates
- Department of Immunology and Physiology, College of Medicine and Health Sciences, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Vincent Chan
- Biomedical Engineering and Healthcare Engineering Innovation Center, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Peter R Corridon
- Department of Immunology and Physiology, College of Medicine and Health Sciences, Khalifa University, Abu Dhabi, United Arab Emirates
- Center for Biotechnology, Khalifa University, Abu Dhabi, United Arab Emirates
| |
Collapse
|
15
|
Blume C, Kraus X, Heene S, Loewner S, Stanislawski N, Cholewa F, Blume H. Vascular implants - new aspects for in situ tissue engineering. Eng Life Sci 2022; 22:344-360. [PMID: 35382534 PMCID: PMC8961049 DOI: 10.1002/elsc.202100100] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 12/10/2021] [Accepted: 12/19/2021] [Indexed: 12/12/2022] Open
Abstract
Conventional synthetic vascular grafts require ongoing anticoagulation, and autologous venous grafts are often not available in elderly patients. This review highlights the development of bioartificial vessels replacing brain-dead donor- or animal-deriving vessels with ongoing immune reactivity. The vision for such bio-hybrids exists in a combination of biodegradable scaffolds and seeding with immune-neutral cells, and here different cells sources such as autologous progenitor cells or stem cells are relevant. This kind of in situ tissue engineering depends on a suitable bioreactor system with elaborate monitoring systems, three-dimensional (3D) visualization and a potential of cell conditioning into the direction of the targeted vascular cell phenotype. Necessary bioreactor tools for dynamic and pulsatile cultivation are described. In addition, a concept for design of vasa vasorum is outlined, that is needed for sustainable nutrition of the wall structure in large caliber vessels. For scaffold design and cell adhesion additives, different materials and technologies are discussed. 3D printing is introduced as a relatively new field with promising prospects, for example, to create complex geometries or micro-structured surfaces for optimal cell adhesion and ingrowth in a standardized and custom designed procedure. Summarizing, a bio-hybrid vascular prosthesis from a controlled biotechnological process is thus coming more and more into view. It has the potential to withstand strict approval requirements applied for advanced therapy medicinal products.
Collapse
Affiliation(s)
- Cornelia Blume
- Institute for Technical ChemistryLeibniz University HannoverHannoverGermany
| | - Xenia Kraus
- Institute for Technical ChemistryLeibniz University HannoverHannoverGermany
| | - Sebastian Heene
- Institute for Technical ChemistryLeibniz University HannoverHannoverGermany
| | - Sebastian Loewner
- Institute for Technical ChemistryLeibniz University HannoverHannoverGermany
| | - Nils Stanislawski
- Institute for Microelectronic SystemsLeibniz University HannoverHannoverGermany
| | - Fabian Cholewa
- Institute for Microelectronic SystemsLeibniz University HannoverHannoverGermany
| | - Holger Blume
- Institute for Microelectronic SystemsLeibniz University HannoverHannoverGermany
| |
Collapse
|
16
|
Durán-Rey D, Crisóstomo V, Sánchez-Margallo JA, Sánchez-Margallo FM. Systematic Review of Tissue-Engineered Vascular Grafts. Front Bioeng Biotechnol 2021; 9:771400. [PMID: 34805124 PMCID: PMC8595218 DOI: 10.3389/fbioe.2021.771400] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 10/18/2021] [Indexed: 01/01/2023] Open
Abstract
Pathologies related to the cardiovascular system are the leading causes of death worldwide. One of the main treatments is conventional surgery with autologous transplants. Although donor grafts are often unavailable, tissue-engineered vascular grafts (TEVGs) show promise for clinical treatments. A systematic review of the recent scientific literature was performed using PubMed (Medline) and Web of Science databases to provide an overview of the state-of-the-art in TEVG development. The use of TEVG in human patients remains quite restricted owing to the presence of vascular stenosis, existence of thrombi, and poor graft patency. A total of 92 original articles involving human patients and animal models were analyzed. A meta-analysis of the influence of the vascular graft diameter on the occurrence of thrombosis and graft patency was performed for the different models analyzed. Although there is no ideal animal model for TEVG research, the murine model is the most extensively used. Hybrid grafting, electrospinning, and cell seeding are currently the most promising technologies. The results showed that there is a tendency for thrombosis and non-patency in small-diameter grafts. TEVGs are under constant development, and research is oriented towards the search for safe devices.
Collapse
Affiliation(s)
- David Durán-Rey
- Laparoscopy Unit, Jesús Usón Minimally Invasive Surgery Centre, Cáceres, Spain
| | - Verónica Crisóstomo
- Cardiovascular Unit, Jesús Usón Minimally Invasive Surgery Centre, Cáceres, Spain.,Centro de Investigacion Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Instituto de Salud Carlos III, Madrid, Spain
| | - Juan A Sánchez-Margallo
- Bioengineering and Health Technologies Unit, Jesús Usón Minimally Invasive Surgery Centre, Cáceres, Spain
| | - Francisco M Sánchez-Margallo
- Centro de Investigacion Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Instituto de Salud Carlos III, Madrid, Spain.,Scientific Direction, Jesús Usón Minimally Invasive Surgery Centre, Cáceres, Spain
| |
Collapse
|
17
|
Rodriguez-Soto MA, Suarez Vargas N, Riveros A, Camargo CM, Cruz JC, Sandoval N, Briceño JC. Failure Analysis of TEVG's I: Overcoming the Initial Stages of Blood Material Interaction and Stabilization of the Immune Response. Cells 2021; 10:3140. [PMID: 34831361 PMCID: PMC8625197 DOI: 10.3390/cells10113140] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 10/28/2021] [Accepted: 11/06/2021] [Indexed: 12/16/2022] Open
Abstract
Vascular grafts (VG) are medical devices intended to replace the function of a diseased vessel. Current approaches use non-biodegradable materials that struggle to maintain patency under complex hemodynamic conditions. Even with the current advances in tissue engineering and regenerative medicine with the tissue engineered vascular grafts (TEVGs), the cellular response is not yet close to mimicking the biological function of native vessels, and the understanding of the interactions between cells from the blood and the vascular wall with the material in operative conditions is much needed. These interactions change over time after the implantation of the graft. Here we aim to analyze the current knowledge in bio-molecular interactions between blood components, cells and materials that lead either to an early failure or to the stabilization of the vascular graft before the wall regeneration begins.
Collapse
Affiliation(s)
- Maria A. Rodriguez-Soto
- Department of Biomedical Engineering, Universidad de los Andes, Bogotá 111711, Colombia; (N.S.V.); (A.R.); (C.M.C.); (J.C.C.)
| | - Natalia Suarez Vargas
- Department of Biomedical Engineering, Universidad de los Andes, Bogotá 111711, Colombia; (N.S.V.); (A.R.); (C.M.C.); (J.C.C.)
| | - Alejandra Riveros
- Department of Biomedical Engineering, Universidad de los Andes, Bogotá 111711, Colombia; (N.S.V.); (A.R.); (C.M.C.); (J.C.C.)
| | - Carolina Muñoz Camargo
- Department of Biomedical Engineering, Universidad de los Andes, Bogotá 111711, Colombia; (N.S.V.); (A.R.); (C.M.C.); (J.C.C.)
| | - Juan C. Cruz
- Department of Biomedical Engineering, Universidad de los Andes, Bogotá 111711, Colombia; (N.S.V.); (A.R.); (C.M.C.); (J.C.C.)
| | - Nestor Sandoval
- Department of Congenital Heart Disease and Cardiovascular Surgery, Fundación Cardio Infantil Instituto de Cardiología, Bogotá 111711, Colombia;
| | - Juan C. Briceño
- Department of Biomedical Engineering, Universidad de los Andes, Bogotá 111711, Colombia; (N.S.V.); (A.R.); (C.M.C.); (J.C.C.)
- Department of Research, Fundación Cardio Infantil Instituto de Cardiología, Bogotá 111711, Colombia
| |
Collapse
|
18
|
Kimicata M, Mahadik B, Fisher JP. Long-Term Sustained Drug Delivery via 3D Printed Masks for the Development of a Heparin-Loaded Interlayer in Vascular Tissue Engineering Applications. ACS APPLIED MATERIALS & INTERFACES 2021; 13:50812-50822. [PMID: 34670077 DOI: 10.1021/acsami.1c16938] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Current approaches in small-diameter vascular grafts for coronary artery bypass surgeries fail to address physiological variations along the graft that contribute to thrombus formation and ultimately graft failure. We present an innovative interlayer drug delivery system that can be utilized for the sustained delivery of heparin through a graft with a high degree of temporal and spatial control. A heparin-loaded gelatin methacrylate (gelMA) interlayer sits within a biohybrid composed of decellularized bovine pericardium (dECM) and poly(propylene fumarate) (PPF), and its UV crosslinking is controlled via three-dimensional (3D) printed shadow masks. The masks can be readily designed to modulate the incident light intensity on the graft, enabling us to control the resultant gelMA crosslinking and properties. A high heparin loading efficiency was obtained in gelMA and was independent of crosslinking. We achieved sustained heparin release over the course of 2 weeks within the biohybrid material using the 3D printed mask patterns. High doses of heparin were observed to have detrimental effects on endothelial cell function. However, when exposed to heparin in a slower, more sustained manner consistent with the masks, endothelial cells behave similarly to untreated cells. Further, slower release profiles cause significantly more release of tissue factor pathway inhibitor, an anticoagulant, than a faster release profile. The heparin-loaded gelMA interlayer we have developed is a useful tool for the temporal and spatial control of heparin release that supports endothelial function and promotes an antithrombotic environment.
Collapse
Affiliation(s)
- Megan Kimicata
- Department of Materials Science and Engineering, University of Maryland, 3121 A. James Clark Hall, College Park, Maryland 20742, United States
- NIBIB/NIH Center for Engineering Complex Tissues, University of Maryland, 3121 A. James Clark Hall, College Park, Maryland 20742, United States
| | - Bhushan Mahadik
- NIBIB/NIH Center for Engineering Complex Tissues, University of Maryland, 3121 A. James Clark Hall, College Park, Maryland 20742, United States
- Fischell Department of Bioengineering, University of Maryland, 3121 A. James Clark Hall, College Park, Maryland 20742, United States
| | - John P Fisher
- NIBIB/NIH Center for Engineering Complex Tissues, University of Maryland, 3121 A. James Clark Hall, College Park, Maryland 20742, United States
- Fischell Department of Bioengineering, University of Maryland, 3121 A. James Clark Hall, College Park, Maryland 20742, United States
| |
Collapse
|
19
|
Håkansson J, Simsa R, Bogestål Y, Jenndahl L, Gustafsson-Hedberg T, Petronis S, Strehl R, Österberg K. Individualized tissue-engineered veins as vascular grafts: A proof of concept study in pig. J Tissue Eng Regen Med 2021; 15:818-830. [PMID: 34318614 DOI: 10.1002/term.3233] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 05/22/2021] [Accepted: 07/22/2021] [Indexed: 11/06/2022]
Abstract
Personalized tissue engineered vascular grafts are a promising advanced therapy medicinal product alternative to autologous or synthetic vascular grafts utilized in blood vessel bypass or replacement surgery. We hypothesized that an individualized tissue engineered vein (P-TEV) would make the body recognize the transplanted blood vessel as autologous, decrease the risk of rejection and thereby avoid lifelong treatment with immune suppressant medication as is standard with allogenic organ transplantation. To individualize blood vessels, we decellularized vena cava from six deceased donor pigs and tested them for cellular removal and histological integrity. A solution with peripheral blood from the recipient pigs was used for individualized reconditioning in a perfusion bioreactor for seven days prior to transplantation. To evaluate safety and functionality of the individualized vascular graft in vivo, we transplanted reconditioned porcine vena cava into six pigs and analyzed histology and patency of the graft at different time points, with three pigs at the final endpoint 4-5 weeks after surgery. Our results showed that the P-TEV was fully patent in all animals, did not induce any occlusion or stenosis formation and we did not find any signs of rejection. The P-TEV showed rapid recellularization in vivo with the luminal surface covered with endothelial cells. In summary, the results indicate that P-TEV is functional and have potential for use as clinical transplant grafts.
Collapse
Affiliation(s)
- Joakim Håkansson
- Chemistry, Biomaterials and Textiles, RISE Research Institutes of Sweden, Borås, Sweden.,Laboratory Medicine, Biomedicine, Gothenburg University, Gothenburg, Sweden
| | | | - Yalda Bogestål
- Chemistry, Biomaterials and Textiles, RISE Research Institutes of Sweden, Borås, Sweden
| | | | | | - Sarunas Petronis
- Chemistry, Biomaterials and Textiles, RISE Research Institutes of Sweden, Borås, Sweden
| | | | - Klas Österberg
- Molecular and Clinical Medicine, Sahlgrenska Academy, Gothenburg, Sweden
| |
Collapse
|
20
|
Seiffert N, Tang P, Keshi E, Reutzel-Selke A, Moosburner S, Everwien H, Wulsten D, Napierala H, Pratschke J, Sauer IM, Hillebrandt KH, Struecker B. In vitro recellularization of decellularized bovine carotid arteries using human endothelial colony forming cells. J Biol Eng 2021; 15:15. [PMID: 33882982 PMCID: PMC8059238 DOI: 10.1186/s13036-021-00266-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Accepted: 04/07/2021] [Indexed: 01/14/2023] Open
Abstract
BACKGROUND Many patients suffering from peripheral arterial disease (PAD) are dependent on bypass surgery. However, in some patients no suitable replacements (i.e. autologous or prosthetic bypass grafts) are available. Advances have been made to develop autologous tissue engineered vascular grafts (TEVG) using endothelial colony forming cells (ECFC) obtained by peripheral blood draw in large animal trials. Clinical translation of this technique, however, still requires additional data for usability of isolated ECFC from high cardiovascular risk patients. Bovine carotid arteries (BCA) were decellularized using a combined SDS (sodium dodecyl sulfate) -free mechanical-osmotic-enzymatic-detergent approach to show the feasibility of xenogenous vessel decellularization. Decellularized BCA chips were seeded with human ECFC, isolated from a high cardiovascular risk patient group, suffering from diabetes, hypertension and/or chronic renal failure. ECFC were cultured alone or in coculture with rat or human mesenchymal stromal cells (rMSC/hMSC). Decellularized BCA chips were evaluated for biochemical, histological and mechanical properties. Successful isolation of ECFC and recellularization capabilities were analyzed by histology. RESULTS Decellularized BCA showed retained extracellular matrix (ECM) composition and mechanical properties upon cell removal. Isolation of ECFC from the intended target group was successfully performed (80% isolation efficiency). Isolated cells showed a typical ECFC-phenotype. Upon recellularization, co-seeding of patient-isolated ECFC with rMSC/hMSC and further incubation was successful for 14 (n = 9) and 23 (n = 5) days. Reendothelialization (rMSC) and partial reendothelialization (hMSC) was achieved. Seeded cells were CD31 and vWF positive, however, human cells were detectable for up to 14 days in xenogenic cell-culture only. Seeding of ECFC without rMSC was not successful. CONCLUSION Using our refined decellularization process we generated easily obtainable TEVG with retained ECM- and mechanical quality, serving as a platform to develop small-diameter (< 6 mm) TEVG. ECFC isolation from the cardiovascular risk target group is possible and sufficient. Survival of diabetic ECFC appears to be highly dependent on perivascular support by rMSC/hMSC under static conditions. ECFC survival was limited to 14 days post seeding.
Collapse
Affiliation(s)
- Nicolai Seiffert
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Department of Surgery, Campus Charité Mitte
- Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany.,Department for Trauma and Orthopedic Surgery, Vivantes-Hospital Spandau, Berlin, Germany
| | - Peter Tang
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Department of Surgery, Campus Charité Mitte
- Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Eriselda Keshi
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Department of Surgery, Campus Charité Mitte
- Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Anja Reutzel-Selke
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Department of Surgery, Campus Charité Mitte
- Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Simon Moosburner
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Department of Surgery, Campus Charité Mitte
- Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Hannah Everwien
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Department of Surgery, Campus Charité Mitte
- Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany.,Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Dag Wulsten
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany.,Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Hendrik Napierala
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Department of Surgery, Campus Charité Mitte
- Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Johann Pratschke
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Department of Surgery, Campus Charité Mitte
- Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Igor M Sauer
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Department of Surgery, Campus Charité Mitte
- Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany.
| | - Karl H Hillebrandt
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Department of Surgery, Campus Charité Mitte
- Campus Virchow-Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany.,Berlin Institute of Health at Charité - Universitätsmedizin Berlin, BIH Academy, Clinician Scientist Program, Charitéplatz 1, 10117, Berlin, Germany
| | - Benjamin Struecker
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin, BIH Academy, Clinician Scientist Program, Charitéplatz 1, 10117, Berlin, Germany.,Department of General, Visceral and Transplant Surgery, University Hospital Münster, Münster, Germany
| |
Collapse
|
21
|
Kobayashi M, Ohara M, Hashimoto Y, Nakamura N, Fujisato T, Kimura T, Kishida A. In vitro evaluation of surface biological properties of decellularized aorta for cardiovascular use. J Mater Chem B 2021; 8:10977-10989. [PMID: 33174886 DOI: 10.1039/d0tb01830a] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The aim of this study was to determine an in vitro evaluation method that could directly predict in vivo performance of decellularized tissue for cardiovascular use. We hypothesized that key factors for in vitro evaluation would be found by in vitro assessment of decellularized aortas that previously showed good performance in vivo, such as high patency. We chose porcine aortas, decellularized using three different decellularization methods: sodium dodecyl-sulfate (SDS), freeze-thawing, and high-hydrostatic pressurization (HHP). Immunohistological staining, a blood clotting test, scanning electron microscopy (SEM) analysis, and recellularization of endothelial cells were used for the in vitro evaluation. There was a significant difference in the remaining extracellular matrix (ECM) components, ECM structure, and the luminal surface structure between the three decellularized aortas, respectively, resulting in differences in the recellularization of endothelial cells. On the other hand, there was no difference observed in the blood clotting test. These results suggested that the blood clotting test could be a key evaluation method for the prediction of in vivo performance. In addition, evaluation of the luminal surface structure and the recellularization experiment should be packaged as an in vitro evaluation because the long-term patency was probably affected. The evaluation approach in this study may be useful to establish regulations and a quality management system for a cardiovascular prosthesis.
Collapse
Affiliation(s)
- Mako Kobayashi
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-surugadai, Chiyoda-ku, Tokyo 101-0062, Japan.
| | - Masako Ohara
- Department of Bioscience and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-ku, Saitama-shi, Saitama 337-8570, Japan
| | - Yoshihide Hashimoto
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-surugadai, Chiyoda-ku, Tokyo 101-0062, Japan.
| | - Naoko Nakamura
- Department of Bioscience and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-ku, Saitama-shi, Saitama 337-8570, Japan
| | - Toshiya Fujisato
- Department of Biomedical Engineering, Osaka Institute of Technology, 5-16-1 Omiya, Asahi-ku, Osaka 535-8585, Japan
| | - Tsuyoshi Kimura
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-surugadai, Chiyoda-ku, Tokyo 101-0062, Japan.
| | - Akio Kishida
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-surugadai, Chiyoda-ku, Tokyo 101-0062, Japan.
| |
Collapse
|
22
|
Fang S, Ellman DG, Andersen DC. Review: Tissue Engineering of Small-Diameter Vascular Grafts and Their In Vivo Evaluation in Large Animals and Humans. Cells 2021; 10:713. [PMID: 33807009 PMCID: PMC8005053 DOI: 10.3390/cells10030713] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 03/10/2021] [Accepted: 03/15/2021] [Indexed: 12/15/2022] Open
Abstract
To date, a wide range of materials, from synthetic to natural or a mixture of these, has been explored, modified, and examined as small-diameter tissue-engineered vascular grafts (SD-TEVGs) for tissue regeneration either in vitro or in vivo. However, very limited success has been achieved due to mechanical failure, thrombogenicity or intimal hyperplasia, and improvements of the SD-TEVG design are thus required. Here, in vivo studies investigating novel and relative long (10 times of the inner diameter) SD-TEVGs in large animal models and humans are identified and discussed, with emphasis on graft outcome based on model- and graft-related conditions. Only a few types of synthetic polymer-based SD-TEVGs have been evaluated in large-animal models and reflect limited success. However, some polymers, such as polycaprolactone (PCL), show favorable biocompatibility and potential to be further modified and improved in the form of hybrid grafts. Natural polymer- and cell-secreted extracellular matrix (ECM)-based SD-TEVGs tested in large animals still fail due to a weak strength or thrombogenicity. Similarly, native ECM-based SD-TEVGs and in-vitro-developed hybrid SD-TEVGs that contain xenogeneic molecules or matrix seem related to a harmful graft outcome. In contrast, allogeneic native ECM-based SD-TEVGs, in-vitro-developed hybrid SD-TEVGs with allogeneic banked human cells or isolated autologous stem cells, and in-body tissue architecture (IBTA)-based SD-TEVGs seem to be promising for the future, since they are suitable in dimension, mechanical strength, biocompatibility, and availability.
Collapse
Affiliation(s)
- Shu Fang
- Laboratory of Molecular and Cellular Cardiology, Department of Clinical Biochemistry and Pharmacology, Odense University Hospital, J. B. Winsløwsvej 25, 5000 Odense C, Denmark; (D.G.E.); (D.C.A.)
- The Danish Regenerative Center, Odense University Hospital, J. B. Winsløwsvej 4, 5000 Odense C, Denmark
- Institute of Clinical Research, University of Southern Denmark, J. B. Winsløwsvej 19, 5000 Odense C, Denmark
| | - Ditte Gry Ellman
- Laboratory of Molecular and Cellular Cardiology, Department of Clinical Biochemistry and Pharmacology, Odense University Hospital, J. B. Winsløwsvej 25, 5000 Odense C, Denmark; (D.G.E.); (D.C.A.)
- Institute of Clinical Research, University of Southern Denmark, J. B. Winsløwsvej 19, 5000 Odense C, Denmark
| | - Ditte Caroline Andersen
- Laboratory of Molecular and Cellular Cardiology, Department of Clinical Biochemistry and Pharmacology, Odense University Hospital, J. B. Winsløwsvej 25, 5000 Odense C, Denmark; (D.G.E.); (D.C.A.)
- The Danish Regenerative Center, Odense University Hospital, J. B. Winsløwsvej 4, 5000 Odense C, Denmark
- Institute of Clinical Research, University of Southern Denmark, J. B. Winsløwsvej 19, 5000 Odense C, Denmark
| |
Collapse
|
23
|
Allen KB, Adams JD, Badylak SF, Garrett HE, Mouawad NJ, Oweida SW, Parikshak M, Sultan PK. Extracellular Matrix Patches for Endarterectomy Repair. Front Cardiovasc Med 2021; 8:631750. [PMID: 33644135 PMCID: PMC7904872 DOI: 10.3389/fcvm.2021.631750] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 01/25/2021] [Indexed: 12/15/2022] Open
Abstract
Patch repair is the preferred method for arteriotomy closure following femoral or carotid endarterectomy. Choosing among available patch options remains a clinical challenge, as current evidence suggests roughly comparable outcomes between autologous grafts and synthetic and biologic materials. Biologic patches have potential advantages over other materials, including reduced risk for infection, mitigation of an excessive foreign body response, and the potential to remodel into healthy, vascularized tissue. Here we review the use of decellularized extracellular matrix (ECM) for cardiovascular applications, particularly endarterectomy repair, and the capacity of these materials to remodel into native, site-appropriate tissues. Also presented are data from two post-market observational studies of patients undergoing iliofemoral and carotid endarterectomy patch repair as well as one histologic case report in a challenging iliofemoral endarterectomy repair, all with the use of small intestine submucosa (SIS)-ECM. In alignment with previously reported studies, high patency was maintained, and adverse event rates were comparable to previously reported rates of patch angioplasty. Histologic analysis from one case identified constructive remodeling of the SIS-ECM, consistent with the histologic characteristics of the endarterectomized vessel. These clinical and histologic results align with the biologic potential described in the academic ECM literature. To our knowledge, this is the first histologic demonstration of SIS-ECM remodeling into site-appropriate vascular tissues following endarterectomy. Together, these findings support the safety and efficacy of SIS-ECM for patch repair of femoral and carotid arteriotomy.
Collapse
Affiliation(s)
- Keith B Allen
- St. Luke's Hospital of Kansas City, St. Luke's Mid America Heart Institute, Kansas City, MO, United States
| | - Joshua D Adams
- Carilion Clinic Aortic and Endovascular Surgery, Roanoke, VA, United States
| | - Stephen F Badylak
- Department of Bioengineering, Department of Surgery, McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, United States
| | - H Edward Garrett
- Cardiovascular Surgery Clinic, University of Tennessee, Memphis, Memphis, TN, United States
| | | | | | | | | |
Collapse
|
24
|
Cai Q, Liao W, Xue F, Wang X, Zhou W, Li Y, Zeng W. Selection of different endothelialization modes and different seed cells for tissue-engineered vascular graft. Bioact Mater 2021; 6:2557-2568. [PMID: 33665496 PMCID: PMC7887299 DOI: 10.1016/j.bioactmat.2020.12.021] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 12/09/2020] [Accepted: 12/21/2020] [Indexed: 02/06/2023] Open
Abstract
Tissue-engineered vascular grafts (TEVGs) have enormous potential for vascular replacement therapy. However, thrombosis and intimal hyperplasia are important problems associated with TEVGs especially small diameter TEVGs (<6 mm) after transplantation. Endothelialization of TEVGs is a key point to prevent thrombosis. Here, we discuss different types of endothelialization and different seed cells of tissue-engineered vascular grafts. Meanwhile, endothelial heterogeneity is also discussed. Based on it, we provide a new perspective for selecting suitable types of endothelialization and suitable seed cells to improve the long-term patency rate of tissue-engineered vascular grafts with different diameters and lengths. The material, diameter and length of tissue-engineered vascular graft are all key factors affecting its long-term patency. Endothelialization strategies should consider the different diameters and lengths of tissue-engineered vascular grafts. Cell heterogeneity and tissue heterogeneity should be considered in the application of seed cells.
Collapse
Affiliation(s)
- Qingjin Cai
- Department of Cell Biology, Third Military Medical University, Chongqing, 400038, China
| | - Wanshan Liao
- Department of Cell Biology, Third Military Medical University, Chongqing, 400038, China
| | - Fangchao Xue
- Department of Cell Biology, Third Military Medical University, Chongqing, 400038, China
| | - Xiaochen Wang
- Department of Cell Biology, Third Military Medical University, Chongqing, 400038, China
| | - Weiming Zhou
- Department of Cell Biology, Third Military Medical University, Chongqing, 400038, China
| | - Yanzhao Li
- State Key Laboratory of Trauma, Burn and Combined Injury, Chongqing, China
| | - Wen Zeng
- Department of Cell Biology, Third Military Medical University, Chongqing, 400038, China.,State Key Laboratory of Trauma, Burn and Combined Injury, Chongqing, China.,Departments of Neurology, Southwest Hospital, Third Military Medical University, Chongqing, China
| |
Collapse
|
25
|
Rousselle SD. Digital 3D Topographic Microscopy: Bridging the Gaps Between Macroscopy, Microscopy and Scanning Electron Microscopy. Toxicol Pathol 2020; 49:963-970. [PMID: 33371801 DOI: 10.1177/0192623320979908] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Re-endothelialization of vascular lumen after endovascular procedures is a critical healing milestone and is subjected to routine pathological evaluation during preclinical safety assessment of new cardiovascular devices. Gross evaluation, microscopic evaluation, and scanning electron microscopy (SEM) are the methods of choice for evaluation of vascular surfaces. In this article, we present a new digital imaging approach of surface topography herein referred to as topographical digital microscopy (TDM) that is able to meet the objectives of endovascular healing assessment in a single instrumental platform combined with the same sample preparation techniques as for histology or SEM. This platform is taking advantage of digitally managed illumination, X-Y stitching, and Z-stacking to enable direct optical imaging of tissue surfaces at levels of details ranging from the macroscopic to the cellular level. This technique is enabled by advances in digital optical microscopy and provides images in color and 3 dimensions that can help in the analysis, especially in distinguishing biologically meaningful observations from technical preparation artifacts and in visualizing surface topography.
Collapse
|
26
|
Kimicata M, Swamykumar P, Fisher JP. Extracellular Matrix for Small-Diameter Vascular Grafts. Tissue Eng Part A 2020; 26:1388-1401. [PMID: 33231135 PMCID: PMC7759287 DOI: 10.1089/ten.tea.2020.0201] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 11/11/2020] [Indexed: 01/15/2023] Open
Abstract
To treat coronary heart disease, coronary artery bypass grafts are used to divert blood flow around blockages in the coronary arteries. Autologous grafts are the gold standard of care, but they are characterized by their lack of availability, low quality, and high failure rates. Alternatively, tissue-engineered small-diameter vascular grafts made from synthetic or natural polymers have not demonstrated adequate results to replace autologous grafts; synthetic grafts result in a loss of patency due to thrombosis and intimal hyperplasia, whereas scaffolds from natural polymers are generally unable to support the physiological conditions. Extracellular matrix (ECM) from a variety of sources, including cell-derived, 2D, and cannular tissues, has become an increasingly useful tool for this application. The current review examines the ECM-based methods that have recently been investigated in the field and comments on their viability for clinical applications.
Collapse
Affiliation(s)
- Megan Kimicata
- Department of Materials Science and Engineering, University of Maryland, College Park, Maryland, USA
- Center for Engineering Complex Tissues, and University of Maryland, College Park, Maryland, USA
| | - Prateek Swamykumar
- Center for Engineering Complex Tissues, and University of Maryland, College Park, Maryland, USA
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland, USA
| | - John P. Fisher
- Center for Engineering Complex Tissues, and University of Maryland, College Park, Maryland, USA
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland, USA
| |
Collapse
|
27
|
Jafarihaghighi F, Ardjmand M, Mirzadeh A, Hassani MS, Parizi SS. Current challenges and future trends in manufacturing small diameter artificial vascular grafts in bioreactors. Cell Tissue Bank 2020; 21:377-403. [PMID: 32415569 DOI: 10.1007/s10561-020-09837-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Accepted: 05/09/2020] [Indexed: 01/17/2023]
Abstract
Cardiovascular diseases are a leading cause of death. Vascular surgery is mainly used to solve this problem. However, the generation of a functional and suitable substitute for small diameter (< 6 mm) displacement is challengeable. Moreover, synthetic prostheses, made of polyethylene terephthalate and extended polytetrafluoroethylene show have shown insufficient performance. Therefore, the challenges dominating the use of autografts have prevented their efficient use. Tissue engineering is highlighted in regenerative medicine perhaps in aiming to address the issue of end-stage organ failure. While organs and complex tissues require the vascular supply to support the graft survival and render the bioartificial organ role, vascular tissue engineering has shown to be a hopeful method for cell implantation by the production of tissues in vitro. Bioreactors are a salient point in vascular tissue engineering due to the capability for reproducible and controlled variations showing a new horizon in blood vessel substitution. This review strives to display the overview of current concepts in the development of small-diameter by using bioreactors. In this work, we show a critical look at different factors for developing small-diameter and give suggestions for future studies.
Collapse
Affiliation(s)
- Farid Jafarihaghighi
- Department of Chemical Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran
| | - Mehdi Ardjmand
- Department of Chemical Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran.
| | - Abolfazl Mirzadeh
- Department of Biochemistry and Molecular Biology, Bio21 Molecular Science and Biotechnology Institute, University of Melbourne, Parkville, VIC, 3052, Australia
| | - Mohammad Salar Hassani
- Department of Chemical Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran
| | - Shahriar Salemi Parizi
- Department of Chemical Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran
- Young Researchers and Elite Club, South Tehran Branch, Islamic Azad University, Tehran, Iran
| |
Collapse
|
28
|
Davidov T, Efraim Y, Dahan N, Baruch L, Machluf M. Porcine arterial ECM hydrogel: Designing an in vitro angiogenesis model for long-term high-throughput research. FASEB J 2020; 34:7745-7758. [PMID: 32337805 DOI: 10.1096/fj.202000264] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Accepted: 03/23/2020] [Indexed: 12/11/2022]
Abstract
The field of angiogenesis research provides deep understanding regarding this important process, which plays fundamental roles in tissue development and different abnormalities. In vitro models offer the advantages of low-cost high-throughput research of angiogenesis while sparing animal lives, and enabling the use of human cells. Nevertheless, prevailing in vitro models lack stability and are limited to a few days' assays. This study, therefore, examines the hypothesis that closely mimicking the vascular microenvironment can more reliably support longer angiogenesis processes in vitro. To this end, porcine arterial extracellular matrix (paECM)- a key component of blood vessels-was isolated and processed into a thermally induced hydrogel and characterized in terms of composition, structure, and mechanical properties, thus confirming the preservation of important characteristics of arterial extracellular matrix. This unique hydrogel was further tailored into a three-dimensional model of angiogenesis using endothelial cells and supporting cells, in a configuration that allows high-throughput quantitative analysis of cell viability and proliferation, cell migration, and apoptosis, thus revealing the advantages of paECM over frequently used biomaterials. Markedly, when applied with well-known effectors of angiogenesis, the model measures reflected the expected response, hence validating its efficacy and establishing its potential as a promising tool for the research of angiogenesis.
Collapse
Affiliation(s)
- Tzila Davidov
- Faculty of Biotechnology & Food Engineering, Technion - Israel Institute of Technology, Haifa, Israel
| | - Yael Efraim
- Faculty of Biotechnology & Food Engineering, Technion - Israel Institute of Technology, Haifa, Israel
| | - Nitsan Dahan
- Infrastructure Unit, Life Science and Engineering Center, Technion - Israel Institute of Technology, Haifa, Israel
| | - Limor Baruch
- Faculty of Biotechnology & Food Engineering, Technion - Israel Institute of Technology, Haifa, Israel
| | - Marcelle Machluf
- Faculty of Biotechnology & Food Engineering, Technion - Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
29
|
Matsushita H, Inoue T, Abdollahi S, Yeung E, Ong CS, Lui C, Pitaktong I, Nelson K, Johnson J, Hibino N. Corrugated nanofiber tissue-engineered vascular graft to prevent kinking for arteriovenous shunts in an ovine model. JVS Vasc Sci 2020; 1:100-108. [PMID: 34617042 PMCID: PMC8489245 DOI: 10.1016/j.jvssci.2020.03.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Accepted: 03/25/2020] [Indexed: 01/14/2023] Open
Abstract
Objective Prosthetic grafts are often needed in open vascular procedures. However, the smaller diameter prosthetic grafts (<6 mm) have low patency and often result in complications from infection. Tissue-engineered vascular grafts (TEVGs) are a promising replacement for small diameter prosthetic grafts. TEVGs start as a biodegradable scaffold to promote autologous cell proliferation and functional neotissue regeneration. Owing to the limitations of graft materials; however, most TEVGs are rigid and easily kinked when implanted in limited spaces, which precludes clinical application. We have developed a novel corrugated nanofiber graft to prevent kinking. Methods TEVGs with corrugated walls (5-mm internal diameter by 10 cm length) were created by electrospinning a blend of poly-ε-caprolactone and poly(L-lactide-co-caprolactone). The biodegradable grafts were then implanted between the carotid artery and the external jugular vein in a U-shape using an ovine model. TEVGs were implanted on both the left and right side of a sheep (n = 4, grafts = 8). The grafts were explanted 1 month after implantation and inspected with mechanical and histologic analyses. Graft patency was confirmed by measuring graft diameter and blood flow velocity using ultrasound, which was performed on day 4 and every following week after implantation. Results All sheep survived postoperatively except for one sheep that died of acute heart failure 2 weeks after implantation. The graft patency rate was 87.5% (seven grafts out of eight) with one graft becoming occluded in the early phase after implantation. There was no significant kinking of the grafts. Overall, endothelial cells were observed in the grafts 1 month after the surgeries without graft rupture, calcification, or aneurysmal change. Conclusions Our novel corrugated nanofiber vascular graft displayed neotissue formation without kinking in large animal model. This basic science research article reported tissue-engineered vascular grafts for arteriovenous shunt procedures. Nanofibrous grafts were electrospun with polyglycolic acid and poly-ε-caprolactone with a corrugated wall design to prevent graft kinking. The tissue-engineered vascular grafts were then implanted in U-shape between the carotid artery and the external jugular vein of an ovine model. This graft had 87.5% patency rate and did not display significant kinking. Overall, re-endothelialization was observed in the grafts one month after the surgeries without graft rupture, calcification or aneurysmal change. This graft is a promising alternative to small diameter prosthetic grafts.
Collapse
Affiliation(s)
| | - Takahiro Inoue
- Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, Md
| | - Sara Abdollahi
- Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, Md
| | - Enoch Yeung
- Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, Md
| | - Chin Siang Ong
- Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, Md
| | - Cecillia Lui
- Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, Md
| | - Isaree Pitaktong
- Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, Md
| | | | | | - Narutoshi Hibino
- Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, Md
| |
Collapse
|
30
|
Endothelialization of arterial vascular grafts by circulating monocytes. Nat Commun 2020; 11:1622. [PMID: 32238801 PMCID: PMC7113268 DOI: 10.1038/s41467-020-15361-2] [Citation(s) in RCA: 67] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Accepted: 03/05/2020] [Indexed: 12/15/2022] Open
Abstract
Recently our group demonstrated that acellular tissue engineered vessels (A-TEVs) comprised of small intestinal submucosa (SIS) immobilized with heparin and vascular endothelial growth factor (VEGF) could be implanted into the arterial system of a pre-clinical ovine animal model, where they endothelialized within one month and remained patent. Here we report that immobilized VEGF captures blood circulating monocytes (MC) with high specificity under a range of shear stresses. Adherent MC differentiate into a mixed endothelial (EC) and macrophage (Mφ) phenotype and further develop into mature EC that align in the direction of flow and produce nitric oxide under high shear stress. In-vivo, newly recruited cells on the vascular lumen express MC markers and at later times they co-express MC and EC-specific proteins and maintain graft patency. This novel finding indicates that the highly prevalent circulating MC contribute directly to the endothelialization of acellular vascular grafts under the right chemical and biomechanical cues. Acellular tissue engineered vessels functionalised with VEGF are coated with a layer of endothelial cells after in vivo implantation, but the source of the cells are unknown. Here the authors provide evidence that monocytes expressing VEGF receptors can transdifferentiate into endothelial cells via a macrophage intermediate.
Collapse
|
31
|
Kiros S, Lin S, Xing M, Mequanint K. Embryonic Mesenchymal Multipotent Cell Differentiation on Electrospun Biodegradable Poly(ester amide) Scaffolds for Model Vascular Tissue Fabrication. Ann Biomed Eng 2020; 48:980-991. [PMID: 31062257 DOI: 10.1007/s10439-019-02276-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2019] [Accepted: 04/22/2019] [Indexed: 12/17/2022]
Abstract
Vascular differentiation of stem cells and matrix component production on electrospun tubular scaffolds is desirable to engineer blood vessels. The mouse embryonic multipotent mesenchymal progenitor cell line (10T1/2) provides an excellent tool for tissue engineering since it shares similar differentiation characteristics with mesenchymal stem cells. Although 10T1/2 cells have been widely studied in the context of skeletal tissue engineering, their differentiation to smooth muscle lineage is less known. In this study, we fabricated tubular electrospun poly(ester amide) (PEA) fibers from L-phenylalanine-derived biodegradable biomaterials and investigated cell-scaffold interactions as well as their differentiation into vascular smooth muscle cell and subsequent elastin expression. PEA scaffolds fabricated under different collector speeds did not have an impact on the fiber directionality/orientation. 10T1/2 cytocompatibility and proliferation studies showed that PEA fibres were not cytotoxic and were able to support proliferation for 14 days. Furthermore, cells were observed infiltrating the fibrous scaffolds despite the small pore sizes (~ 5 µm). Vascular differentiation studies of 10T1/2 cells using qPCR, Western blot, and immunostaining showed a TGFβ1-induced upregulation of vascular smooth muscle cell (VSMC)-specific markers smooth muscle alpha-actin (SM-α-actin) and smooth muscle myosin heavy chain (SM-MHC). Differentiated 10T1/2 cells produced both elastin and fibrillin-1 suggesting the potential of fibrous PEA scaffolds to fabricate model vascular tissues.
Collapse
Affiliation(s)
- Sarah Kiros
- School of Biomedical Engineering, University of Western Ontario, London, ON, N6A 5B9, Canada
| | - Shigang Lin
- Department of Chemical & Biochemical Engineering, University of Western Ontario, London, ON, N6A 5B9, Canada
| | - Malcolm Xing
- Department of Mechanical Engineering, University of Manitoba, 66 Chancellors Circle, Winnipeg, R3T 2N2, Canada
| | - Kibret Mequanint
- School of Biomedical Engineering, University of Western Ontario, London, ON, N6A 5B9, Canada.
- Department of Chemical & Biochemical Engineering, University of Western Ontario, London, ON, N6A 5B9, Canada.
| |
Collapse
|
32
|
Van de Walle AB, Moore MC, McFetridge PS. Sequential adaptation of perfusion and transport conditions significantly improves vascular construct recellularization and biomechanics. J Tissue Eng Regen Med 2020; 14:510-520. [PMID: 32012480 DOI: 10.1002/term.3015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 12/25/2019] [Accepted: 01/10/2020] [Indexed: 12/31/2022]
Abstract
Recellularization of ex vivo-derived scaffolds remains a significant hurdle primarily due to the scaffolds subcellular pore size that restricts initial cell seeding to the scaffolds periphery and inhibits migration over time. With the aim to improve cell migration, repopulation, and graft mechanics, the effects of a four-step culture approach were assessed. Using an ex vivo-derived vein as a model scaffold, human smooth muscle cells were first seeded onto its ablumen (Step 1: 3 hr) and an aggressive 0-100% nutrient gradient (lumenal flow under hypotensive pressure) was created to initiate cell migration across the scaffold (Step 2: Day 0 to 19). The effects of a prolonged aggressive nutrient gradient created by this single lumenal flow was then compared with a dual flow (lumenal and ablumenal) in Step 3 (Day 20 to 30). Analyses showed that a single lumenal flow maintained for 30 days resulted in a higher proportion of cells migrating across the scaffold toward the vessel lumen (nutrient source), with improved distribution. In Step 4 (Day 31 to 45), the transition from hypotensive pressure (12/8 mmHg) to normotensive (arterial-like) pressure (120/80 mmHg) was assessed. It demonstrated that recellularized scaffolds exposed to arterial pressures have increased glycosaminoglycan deposition, physiological modulus, and Young's modulus. By using this stepwise conditioning, the challenging recellularization of a vein-based scaffold and its positive remodeling toward arterial biomechanics were obtained.
Collapse
Affiliation(s)
- Aurore B Van de Walle
- Laboratoire Matière et Systèmes, Complexes MSC, UMR 7057, CNRS & University Paris Diderot, Paris, France.,J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL
| | - Marc C Moore
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL.,Stephenson School of Biomedical Engineering, Carson Engineering Center, University of Oklahoma, Norman, OK
| | - Peter S McFetridge
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL
| |
Collapse
|
33
|
Assessment of the healing process after percutaneous implantation of a cardiovascular device: a systematic review. Int J Cardiovasc Imaging 2019; 36:385-394. [PMID: 31745743 DOI: 10.1007/s10554-019-01734-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Accepted: 11/10/2019] [Indexed: 01/16/2023]
Abstract
The healing process, occurring after intra-cardiac and intra-vascular device implantation, starts with fibrin condensation and attraction of inflammatory cells, followed by the formation of fibrous tissue that slowly covers the device. The duration of this process is variable and may be incomplete, which can lead to thrombus formation, dislodgement of the device or stenosis. To better understand this process and the neotissue formation, animal models were developed: small (rats and rabbits) and large (sheep, pigs, dogs and baboons) animal models for intra-vascular device implantation; sheep and pigs for intra-cardiac device implantation. After intra-vascular and intra-cardiac device implantation in these animal models, in vitro techniques, i.e. histology, which is the gold standard and scanning electron microscopy, were used to assess the device coverage, characterize the cell constitution and detect complications such as thrombosis. In humans, optical coherence tomography and intra-vascular ultrasounds are both invasive modalities used after stent implantation to assess the structure of the vessels, atheroma plaque and complications. Non-invasive techniques (computed tomography and magnetic resonance imaging) are in development in humans and animal models for tissue characterization (fibrosis), device remodeling evaluation and device implantation complications (thrombosis and stenosis). This review aims to (1) present the experimental models used to study this process on cardiac devices; (2) focus on the in vitro techniques and invasive modalities used currently in humans for intra-vascular and intra-cardiac devices and (3) assess the future developments of non-invasive techniques in animal models and humans for intra-cardiac devices.
Collapse
|
34
|
Tomášek P, Tonar Z, Grajciarová M, Kural T, Turek D, Horáková J, Pálek R, Eberlová L, Králíčková M, Liška V. Histological mapping of porcine carotid arteries - An animal model for the assessment of artificial conduits suitable for coronary bypass grafting in humans. Ann Anat 2019; 228:151434. [PMID: 31704146 DOI: 10.1016/j.aanat.2019.151434] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 09/12/2019] [Accepted: 10/11/2019] [Indexed: 11/16/2022]
Abstract
BACKGROUND Using animal models in experimental medicine requires mapping of their anatomical variability. Porcine common carotid arteries (CCA) are often preferred for the preclinical testing of vascular grafts due to their anatomical and physiological similarity to human small-diameter arteries. Comparing the microscopic structure of animal model organs to their human counterparts reveals the benefits and limitations of translational medicine. METHODS Using quantitative histology and stereology, we performed an extensive mapping of the regional proximodistal differences in the fractions of elastin, collagen, and smooth muscle actin as well as the intima-media and wall thicknesses among 404 segments (every 1 cm) of porcine CCAs collected from male and female pigs (n = 21). We also compared the microscopic structure of porcine CCAs with segments of human coronary arteries and one of the preferred arterial conduits used for the coronary artery bypass grafting (CABG), namely, the internal thoracic artery (ITA) (n = 21 human cadavers). RESULTS The results showed that the histological structure of left and right porcine CCA can be considered equivalent, provided that gross anatomical variations of the regular branching patterns are excluded. The proximal elastic carotid (51.2% elastin, 4.2% collagen, and 37.2% actin) transitioned to more muscular middle segments (23.5% elastin, 4.9% collagen, 54.3% actin) at the range of 2-3 centimeters and then to even more muscular distal segments (17.2% elastin, 4.9% collagen, 64.0% actin). The resulting morphometric data set shows the biological variability of the artery and is made available for biomechanical modeling and for performing a power analysis and calculating the minimum number of samples per group when planning further experiments with this widely used large animal model. CONCLUSIONS Comparison of porcine carotids with human coronary arteries and ITA revealed the benefits and the limitations of using porcine CCAs as a valid model for testing bioengineered small-diameter CABG vascular conduits. Morphometry of human coronary arteries and ITA provided more realistic data for tailoring multilayered artificial vascular prostheses and the ranges of values within which the conduits should be tested in the future. Despite their limitations, porcine CCAs remain a widely used and well-characterized large animal model that is available for a variety of experiments in vascular surgery.
Collapse
Affiliation(s)
- Petr Tomášek
- Department of Histology and Embryology and Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Karlovarska 48, 301 66 Pilsen, Czech Republic; Department of Forensic Medicine, Second Faculty of Medicine, Charles University and Na Bulovce Hospital, Budinova 2, 180 81 Prague, Czech Republic
| | - Zbyněk Tonar
- Department of Histology and Embryology and Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Karlovarska 48, 301 66 Pilsen, Czech Republic.
| | - Martina Grajciarová
- Department of Histology and Embryology and Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Karlovarska 48, 301 66 Pilsen, Czech Republic
| | - Tomáš Kural
- Department of Histology and Embryology and Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Karlovarska 48, 301 66 Pilsen, Czech Republic
| | - Daniel Turek
- First Faculty of Medicine, Charles University in Prague, Katerinska 32, 121 08 Prague 2, Czech Republic; Department of Cardiac Surgery, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague, Czech Republic
| | - Jana Horáková
- Department of Nonwovens and Nanofibrous Materials, Faculty of Textile Engineering, Technical University of Liberec, Studentska 2, 461 17 Liberec, Czech Republic
| | - Richard Pálek
- Department of Surgery and Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Husova 3, 306 05 Pilsen, Czech Republic
| | - Lada Eberlová
- Department of Anatomy, Faculty of Medicine in Pilsen, Charles University, Karlovarska 48, 301 66 Pilsen, Czech Republic
| | - Milena Králíčková
- Department of Histology and Embryology and Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Karlovarska 48, 301 66 Pilsen, Czech Republic
| | - Václav Liška
- Department of Surgery and Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Husova 3, 306 05 Pilsen, Czech Republic
| |
Collapse
|
35
|
Ilanlou S, Khakbiz M, Amoabediny G, Mohammadi J. Preclinical studies of acellular extracellular matrices as small-caliber vascular grafts. Tissue Cell 2019; 60:25-32. [DOI: 10.1016/j.tice.2019.07.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2019] [Revised: 07/28/2019] [Accepted: 07/30/2019] [Indexed: 01/09/2023]
|
36
|
Inglis S, Schneider KH, Kanczler JM, Redl H, Oreffo ROC. Harnessing Human Decellularized Blood Vessel Matrices and Cellular Construct Implants to Promote Bone Healing in an Ex Vivo Organotypic Bone Defect Model. Adv Healthc Mater 2019; 8:e1800088. [PMID: 29756272 DOI: 10.1002/adhm.201800088] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 04/10/2018] [Indexed: 12/17/2022]
Abstract
Decellularized matrices offer a beneficial substitute for biomimetic scaffolds in tissue engineering. The current study examines the potential of decellularized placental vessel sleeves (PVS) as a periosteal protective sleeve to enhance bone regeneration in embryonic day 18 chick femurs contained within the PVS and cultured organotypically over a 10 day period. The femurs are inserted into decellularized biocompatibility-tested PVS and maintained in an organotypic culture for a period of 10 days. In femurs containing decellularized PVS, a significant increase in bone volume (p < 0.001) is evident, demonstrated by microcomputed tomography (µCT) compared to femurs without PVS. Histological and immunohistological analyses reveal extensive integration of decellularized PVS with the bone periosteum, and enhanced conservation of bone architecture within the PVS. In addition, the expressions of hypoxia inducible factor-1 alpha (HIF-1α), type II collagen (COL-II), and proteoglycans are observed, indicating a possible repair mechanism via a cartilaginous stage of the bone tissue within the sleeve. The use of decellularized matrices like PVS offers a promising therapeutic strategy in surgical tissue replacement, promoting biocompatibility and architecture of the tissue as well as a factor-rich niche environment with negligible immunogenicity.
Collapse
Affiliation(s)
- Stefanie Inglis
- Bone and Joint Research GroupCentre for Human Development, Stem Cells and RegenerationInstitute of Developmental SciencesSouthampton General HospitalUniversity of Southampton Southampton SO16 6YD UK
| | - Karl Heinrich Schneider
- Center of Biomedical ResearchMedical University of ViennaLudwig Boltzmann Cluster for Cardiovascular Researchp.A.KIM II/Klinische Abteilung für Kardiologie Währinger Gürtel 18‐20 1090 Vienna Austria
| | - Janos M. Kanczler
- Bone and Joint Research GroupCentre for Human Development, Stem Cells and RegenerationInstitute of Developmental SciencesSouthampton General HospitalUniversity of Southampton Southampton SO16 6YD UK
| | - Heinz Redl
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology/AUVA ResearchCenter and Austrian Cluster for Tissue Regeneration Donaueschingenstrasse 13 1200 Vienna Austria
| | - Richard O. C. Oreffo
- Bone and Joint Research GroupCentre for Human Development, Stem Cells and RegenerationInstitute of Developmental SciencesSouthampton General HospitalUniversity of Southampton Southampton SO16 6YD UK
| |
Collapse
|
37
|
Skovrind I, Harvald EB, Juul Belling H, Jørgensen CD, Lindholt JS, Andersen DC. Concise Review: Patency of Small-Diameter Tissue-Engineered Vascular Grafts: A Meta-Analysis of Preclinical Trials. Stem Cells Transl Med 2019; 8:671-680. [PMID: 30920771 PMCID: PMC6591545 DOI: 10.1002/sctm.18-0287] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Accepted: 03/04/2019] [Indexed: 12/13/2022] Open
Abstract
Several patient groups undergoing small‐diameter (<6 mm) vessel bypass surgery have limited autologous vessels for use as grafts. Tissue‐engineered vascular grafts (TEVG) have been suggested as an alternative, but the ideal TEVG remains to be generated, and a systematic overview and meta‐analysis of clinically relevant studies is lacking. We systematically searched PubMed and Embase databases for (pre)clinical trials and identified three clinical and 68 preclinical trials ([>rabbit]; 873 TEVGs) meeting the inclusion criteria. Preclinical trials represented low to medium risk of bias, and binary logistic regression revealed that patency was significantly affected by recellularization, TEVG length, TEVG diameter, surface modification, and preconditioning. In contrast, scaffold types were less important. The patency was 63.5%, 89%, and 100% for TEVGs with a median diameter of 3 mm, 4 mm, and 5 mm, respectively. In the group of recellularized TEVGs, patency was not improved by using smooth muscle cells in addition to endothelial cells nor affected by the endothelial origin, but seems to benefit from a long‐term (46–240 hours) recellularization time. Finally, data showed that median TEVG length (5 cm) and median follow‐up (56 days) used in preclinical settings are relatively inadequate for direct clinical translation. In conclusion, our data imply that future studies should consider a TEVG design that at least includes endothelial recellularization and bioreactor preconditioning, and we suggest that more standard guidelines for testing and reporting TEVGs in large animals should be considered to enable interstudy comparisons and favor a robust and reproducible outcome as well as clinical translation.
Collapse
Affiliation(s)
- Ida Skovrind
- Laboratory of Molecular and Cellular Cardiology, Department of Clinical Biochemistry and Pharmacology, Odense University Hospital, Odense C, Denmark.,Department of Cardiovascular and Renal Research, University of Southern Denmark, Odense C, Denmark
| | - Eva Bang Harvald
- Laboratory of Molecular and Cellular Cardiology, Department of Clinical Biochemistry and Pharmacology, Odense University Hospital, Odense C, Denmark.,Center for Vascular Regeneration, Odense University Hospital, Odense C, Denmark.,Department of Cardiovascular and Renal Research, University of Southern Denmark, Odense C, Denmark
| | - Helene Juul Belling
- Laboratory of Molecular and Cellular Cardiology, Department of Clinical Biochemistry and Pharmacology, Odense University Hospital, Odense C, Denmark.,Department of Cardiovascular and Renal Research, University of Southern Denmark, Odense C, Denmark
| | | | - Jes Sanddal Lindholt
- Department of Cardiac, Thoracic, and Vascular Surgery, Odense University Hospital, Odense C, Denmark
| | - Ditte Caroline Andersen
- Laboratory of Molecular and Cellular Cardiology, Department of Clinical Biochemistry and Pharmacology, Odense University Hospital, Odense C, Denmark.,Center for Vascular Regeneration, Odense University Hospital, Odense C, Denmark.,Department of Cardiovascular and Renal Research, University of Southern Denmark, Odense C, Denmark.,Clinical Institute, University of Southern Denmark, Odense C, Denmark
| |
Collapse
|
38
|
Smith RJ, Yi T, Nasiri B, Breuer CK, Andreadis ST. Implantation of VEGF-functionalized cell-free vascular grafts: regenerative and immunological response. FASEB J 2019; 33:5089-5100. [PMID: 30629890 DOI: 10.1096/fj.201801856r] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Recently, our group demonstrated that immobilized VEGF can capture flowing endothelial cells (ECs) from the blood in vitro and promote endothelialization and patency of acellular tissue-engineered vessels (A-TEVs) into the arterial system of an ovine animal model. Here, we demonstrate implantability of submillimeter diameter heparin and VEGF-decorated A-TEVs in a mouse model and discuss the cellular and immunologic response. At 1 mo postimplantation, the graft lumen was fully endothelialized, as shown by expression of EC markers such as CD144, eNOS, CD31, and VEGFR2. Interestingly, the same cells coexpressed leukocyte/macrophage (Mϕ) markers CD14, CD16, VEGFR1, CD38, and EGR2. Notably, there was a stark difference in the cellular makeup between grafts containing VEGF and those containing heparin alone. In VEGF-containing grafts, infiltrating monocytes (MCs) converted into anti-inflammatory M2-Mϕs, and the grafts developed well-demarcated luminal and medial layers resembling those of native arteries. In contrast, in grafts containing only heparin, MCs converted primarily into M1-Mϕs, and the endothelial and smooth muscle layers were not well defined. Our results indicate that VEGF may play an important role in regulating A-TEV patency and regeneration, possibly by regulating the inflammatory response to the implants.-Smith, R. J., Jr., Yi, T., Nasiri, B., Breuer, C. K., Andreadis, S. T. Implantation of VEGF-functionalized cell-free vascular grafts: regenerative and immunological response.
Collapse
Affiliation(s)
- Randall J Smith
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Amherst, New York, USA
| | - Tai Yi
- Nationwide Children's Hospital, Columbus, Ohio, USA
| | - Bita Nasiri
- Department of Chemical and Biological Engineering, University at Buffalo, State University of New York, Amherst, New York, USA; and
| | | | - Stelios T Andreadis
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Amherst, New York, USA.,Department of Chemical and Biological Engineering, University at Buffalo, State University of New York, Amherst, New York, USA; and.,Center of Excellence in Bioinformatics and Life Sciences, University at Buffalo, State University of New York, Amherst, New York, USA
| |
Collapse
|
39
|
Radke D, Jia W, Sharma D, Fena K, Wang G, Goldman J, Zhao F. Tissue Engineering at the Blood-Contacting Surface: A Review of Challenges and Strategies in Vascular Graft Development. Adv Healthc Mater 2018; 7:e1701461. [PMID: 29732735 PMCID: PMC6105365 DOI: 10.1002/adhm.201701461] [Citation(s) in RCA: 158] [Impact Index Per Article: 22.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 02/09/2018] [Indexed: 12/14/2022]
Abstract
Tissue engineered vascular grafts (TEVGs) are beginning to achieve clinical success and hold promise as a source of grafting material when donor grafts are unsuitable or unavailable. Significant technological advances have generated small-diameter TEVGs that are mechanically stable and promote functional remodeling by regenerating host cells. However, developing a biocompatible blood-contacting surface remains a major challenge. The TEVG luminal surface must avoid negative inflammatory responses and thrombogenesis immediately upon implantation and promote endothelialization. The surface has therefore become a primary focus for research and development efforts. The current state of TEVGs is herein reviewed with an emphasis on the blood-contacting surface. General vascular physiology and developmental challenges and strategies are briefly described, followed by an overview of the materials currently employed in TEVGs. The use of biodegradable materials and stem cells requires careful control of graft composition, degradation behavior, and cell recruitment ability to ensure that a physiologically relevant vessel structure is ultimately achieved. The establishment of a stable monolayer of endothelial cells and the quiescence of smooth muscle cells are critical to the maintenance of patency. Several strategies to modify blood-contacting surfaces to resist thrombosis and control cellular recruitment are reviewed, including coatings of biomimetic peptides and heparin.
Collapse
Affiliation(s)
- Daniel Radke
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI 49931, U.S
| | - Wenkai Jia
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI 49931, U.S
| | - Dhavan Sharma
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI 49931, U.S
| | - Kemin Fena
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI 49931, U.S
| | - Guifang Wang
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI 49931, U.S
| | - Jeremy Goldman
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI 49931, U.S
| | - Feng Zhao
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI 49931, U.S
| |
Collapse
|
40
|
Archer BJ, Uberruck T, Mack JJ, Youssef K, Jarenwattananon NN, Rall D, Wypysek D, Wiese M, Blumich B, Wessling M, Iruela-Arispe ML, Bouchard LS. Noninvasive Quantification of Cell Density in Three-Dimensional Gels by MRI. IEEE Trans Biomed Eng 2018; 66:821-830. [PMID: 30028689 DOI: 10.1109/tbme.2018.2857443] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
OBJECTIVE For tissue engineering, there is a need for quantitative methods to map cell density inside three-dimensional (3-D) bioreactors to assess tissue growth over time. The current cell mapping methods in 2-D cultures are based on optical microscopy. However, optical methods fail in 3-D due to increased opacity of the tissue. We present an approach for measuring the density of cells embedded in a hydrogel to generate quantitative maps of cell density in a living, 3-D tissue culture sample. METHODS Quantification of cell density was obtained by calibrating the 1H T2, magnetization transfer (MT) and diffusion-weighted nuclear magnetic resonance (NMR) signals to samples of known cell density. Maps of cell density were generated by weighting NMR images by these parameters post-calibration. RESULTS The highest sensitivity weighting arose from MT experiments, which yielded a limit of detection (LOD) of [Formula: see text] cells/mL/ √{Hz} in a 400 MHz (9.4 T) magnet. CONCLUSION This mapping technique provides a noninvasive means of visualizing cell growth within optically opaque bioreactors. SIGNIFICANCE We anticipate that such readouts of tissue culture growth will provide valuable feedback for controlled cell growth in bioreactors.
Collapse
|
41
|
In Vivo Performance of Decellularized Vascular Grafts: A Review Article. Int J Mol Sci 2018; 19:ijms19072101. [PMID: 30029536 PMCID: PMC6073319 DOI: 10.3390/ijms19072101] [Citation(s) in RCA: 98] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 07/16/2018] [Accepted: 07/16/2018] [Indexed: 12/12/2022] Open
Abstract
Due to poor vessel quality in patients with cardiovascular diseases, there has been an increased demand for small-diameter tissue-engineered blood vessels that can be used as replacement grafts in bypass surgery. Decellularization techniques to minimize cellular inflammation have been applied in tissue engineering research for the development of small-diameter vascular grafts. The biocompatibility of allogenic or xenogenic decellularized matrices has been evaluated in vitro and in vivo. Both short-term and long-term preclinical studies are crucial for evaluation of the in vivo performance of decellularized vascular grafts. This review offers insight into the various preclinical studies that have been performed using decellularized vascular grafts. Different strategies, such as surface-modified, recellularized, or hybrid vascular grafts, used to improve neoendothelialization and vascular wall remodeling, are also highlighted. This review provides information on the current status and the future development of decellularized vascular grafts.
Collapse
|
42
|
Colunga T, Dalton S. Building Blood Vessels with Vascular Progenitor Cells. Trends Mol Med 2018; 24:630-641. [PMID: 29802036 PMCID: PMC6050017 DOI: 10.1016/j.molmed.2018.05.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Revised: 05/02/2018] [Accepted: 05/03/2018] [Indexed: 12/20/2022]
Abstract
Vascular progenitor cells have been identified from perivascular cell fractions and peripheral blood and bone marrow mononuclear fractions. These vascular progenitors share the ability to generate some of the vascular lineages, including endothelial cells, smooth muscle cells, and pericytes. The potential therapeutic uses for vascular progenitor cells are broad and relate to stroke, ischemic disease, and to the engineering of whole organs and tissues that require a vascular component. This review summarizes the best-characterized sources of vascular progenitor cells and discusses advances in 3D printing and electrospinning using blended polymers for the creation of biomimetic vascular grafts. These advances are pushing the field of regenerative medicine closer to the creation of small-diameter vascular grafts with long-term clinical utility.
Collapse
Affiliation(s)
- Thomas Colunga
- Center for Molecular Medicine, University of Georgia, 325 Riverbend Road, Athens, GA 30605, USA; Department of Biochemistry and Molecular Biology, University of Georgia, 325 Riverbend Road, Athens, GA 30605, USA
| | - Stephen Dalton
- Center for Molecular Medicine, University of Georgia, 325 Riverbend Road, Athens, GA 30605, USA; Department of Biochemistry and Molecular Biology, University of Georgia, 325 Riverbend Road, Athens, GA 30605, USA.
| |
Collapse
|
43
|
Schneider KH, Enayati M, Grasl C, Walter I, Budinsky L, Zebic G, Kaun C, Wagner A, Kratochwill K, Redl H, Teuschl AH, Podesser BK, Bergmeister H. Acellular vascular matrix grafts from human placenta chorion: Impact of ECM preservation on graft characteristics, protein composition and in vivo performance. Biomaterials 2018; 177:14-26. [PMID: 29885585 DOI: 10.1016/j.biomaterials.2018.05.045] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2018] [Revised: 05/18/2018] [Accepted: 05/26/2018] [Indexed: 02/06/2023]
Abstract
Small diameter vascular grafts from human placenta, decellularized with either Triton X-100 (Triton) or SDS and crosslinked with heparin were constructed and characterized. Graft biochemical properties, residual DNA, and protein composition were evaluated to compare the effect of the two detergents on graft matrix composition and structural alterations. Biocompatibility was tested in vitro by culturing the grafts with primary human macrophages and in vivo by subcutaneous implantation of graft conduits (n = 7 per group) into the flanks of nude rats. Subsequently, graft performance was evaluated using an aortic implantation model in Sprague Dawley rats (one month, n = 14). In situ graft imaging was performed using MRI angiography. Retrieved specimens were analyzed by electromyography, scanning electron microscopy, histology and immunohistochemistry to evaluate cell migration and the degree of functional tissue remodeling. Both decellularization methods resulted in grafts of excellent biocompatibility in vitro and in vivo, with low immunogenic potential. Proteomic data revealed removal of cytoplasmic proteins with relative enrichment of ECM proteins in decelluarized specimens of both groups. Noteworthy, LC-Mass Spectrometry analysis revealed that 16 proteins were exclusively preserved in Triton decellularized specimens in comparison to SDS-treated specimens. Aortic grafts showed high patency rates, no signs of thrombus formation, aneurysms or rupture. Conduits of both groups revealed tissue-specific cell migration indicative of functional remodeling. This study strongly suggests that decellularized allogenic grafts from the human placenta have the potential to be used as vascular replacement materials. Both detergents produced grafts with low residual immunogenicity and appropriate mechanical properties. Observed differences in graft characteristics due to preservation method had no impact on successful in vivo performance in the rodent model.
Collapse
Affiliation(s)
- Karl H Schneider
- Ludwig Boltzmann Cluster for Cardiovascular Research, Vienna, Austria; Center for Biomedical Research Medical University of Vienna, Vienna, Austria; Austrian Cluster for Tissue Regeneration, Vienna, Austria
| | - Marjan Enayati
- Ludwig Boltzmann Cluster for Cardiovascular Research, Vienna, Austria; Center for Biomedical Research Medical University of Vienna, Vienna, Austria
| | - Christian Grasl
- Center for Biomedical Research Medical University of Vienna, Vienna, Austria; Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Ingrid Walter
- Department of Pathobiology, University of Veterinary Medicine Vienna, Vienna, Austria
| | - Lubos Budinsky
- Preclinical Imaging Laboratory, Division of Molecular and Gender Imaging, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Gabriel Zebic
- Center for Biomedical Research Medical University of Vienna, Vienna, Austria
| | - Christoph Kaun
- Division of Internal Medicine II, Medical University of Vienna, Vienna, Austria
| | - Anja Wagner
- Department of Pediatric and Adolescent Medicine, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory for Molecular Stress Research in Peritoneal Dialysis, Vienna, Austria
| | - Klaus Kratochwill
- Department of Pediatric and Adolescent Medicine, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory for Molecular Stress Research in Peritoneal Dialysis, Vienna, Austria
| | - Heinz Redl
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology in AUVA Trauma Center, Vienna, Austria; Austrian Cluster for Tissue Regeneration, Vienna, Austria
| | - Andreas H Teuschl
- Department of Biochemical Engineering, University of Applied Sciences Technikum Wien, Vienna, Austria; Austrian Cluster for Tissue Regeneration, Vienna, Austria; City of Vienna Competence Team Siganltransduction, Vienna, Austria
| | - Bruno K Podesser
- Ludwig Boltzmann Cluster for Cardiovascular Research, Vienna, Austria; Center for Biomedical Research Medical University of Vienna, Vienna, Austria; Austrian Cluster for Tissue Regeneration, Vienna, Austria
| | - Helga Bergmeister
- Ludwig Boltzmann Cluster for Cardiovascular Research, Vienna, Austria; Center for Biomedical Research Medical University of Vienna, Vienna, Austria; Austrian Cluster for Tissue Regeneration, Vienna, Austria.
| |
Collapse
|
44
|
van Steenberghe M, Schubert T, Bouzin C, Caravaggio C, Guiot Y, Xhema D, Gianello P. Enhanced Vascular Biocompatibility and Remodeling of Decellularized and Secured Xenogeneic/Allogeneic Matrices in a Porcine Model. Eur Surg Res 2018; 59:58-71. [PMID: 29621750 DOI: 10.1159/000487591] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Accepted: 02/12/2018] [Indexed: 01/13/2023]
Abstract
BACKGROUND/PURPOSE Calcifications and absence of growth potential are the major drawbacks of glutaraldehyde-treated prosthesis. Decellularized and secured xeno-/allogeneic matrices were assessed in a preclinical porcine model for biocompatibility and vascular remodeling in comparison to glutaraldehyde-fixed bovine pericardium (GBP; control). METHODS Native human (fascia lata, pericardium) and porcine tissues (peritoneum) were used and treated. In vitro, biopsies were performed before and after treatment to assess decellularization (hematoxylin and eosin/DAPI). In vivo, each decellularized and control tissue sample was implanted subcutaneously in 4 mini-pigs. In addition, 9 mini-pigs received a patch or a tubularized prosthesis interposition on the carotid artery or abdominal aorta of decellularized (D) human fascia lata (DHFL; n = 4), human pericardium (DHP; n = 9), porcine peritoneum (DPPt; n = 7), and control tissue (GBP: n = 3). Arteries were harvested after 1 month and subcutaneous samples after 15-30 days. Tissues were processed for hematoxylin and eosin/von Kossa staining and immunohistochemistry for CD31, alpha-smooth muscle actin, CD3, and CD68. Histomorphometry was achieved by point counting. RESULTS A 95% decellularization was confirmed for DHP and DPPt, and to a lower degree for DHFL. In the subcutaneous protocol, CD3 infiltration was significantly higher at day 30 in GBP and DHFL, and CD68 infiltration was significantly higher for GBP (p < 0.05). In intravascular study, no deaths, aneurysms, or pseudoaneurysms were observed. Inflammatory reaction was significantly higher for DHFL and GBP (p < 0.05), while it was lower and comparable for DHP/DPPt. DHP and DPPt showed deeper recellularization, and a new arterial wall was characterized. CONCLUSIONS In a preclinical model, DPPt and DHP offered better results than conventional commercialized GBP for biocompatibility and vascular remodeling.
Collapse
Affiliation(s)
- Mathieu van Steenberghe
- Pôle de Chirurgie Expérimentale et Transplantation (CHEX), Institut de Recherche Expérimentale et Clinique, Secteur des Sciences de la Santé, Université Catholique de Louvain, Brussels, Belgium
| | - Thomas Schubert
- Pôle de Chirurgie Expérimentale et Transplantation (CHEX), Institut de Recherche Expérimentale et Clinique, Secteur des Sciences de la Santé, Université Catholique de Louvain, Brussels, Belgium.,Banque de Tissus, Unité de Thérapie Cellulaire et Tissulaire de L'Appareil Locomoteur, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| | - Caroline Bouzin
- IREC Imaging Platform (2IP), Institut de Recherche Expérimentale et Clinique, Secteur des Sciences de la Santé, Université Catholique de Louvain, Brussels, Belgium
| | - Carlo Caravaggio
- Service de Chirurgie Vasculaire, Site Notre-Dame, Centre Hospitalier de Wallonie Picarde (CHwapi), Tournai, Belgium
| | - Yves Guiot
- Service d'Anatomopathologie, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| | - Daela Xhema
- Pôle de Chirurgie Expérimentale et Transplantation (CHEX), Institut de Recherche Expérimentale et Clinique, Secteur des Sciences de la Santé, Université Catholique de Louvain, Brussels, Belgium
| | - Pierre Gianello
- Pôle de Chirurgie Expérimentale et Transplantation (CHEX), Institut de Recherche Expérimentale et Clinique, Secteur des Sciences de la Santé, Université Catholique de Louvain, Brussels, Belgium
| |
Collapse
|
45
|
Chi Ting Au-Yeung G, Sarig U, Sarig H, Bogireddi H, Bronshtein T, Baruch L, Spizzichino A, Bortman J, Freddy BYC, Machluf M, Venkatraman SS. Restoring the biophysical properties of decellularized patches through recellularization. Biomater Sci 2018; 5:1183-1194. [PMID: 28513656 DOI: 10.1039/c7bm00208d] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Various extracellular matrix (ECM) scaffolds, isolated through decellularization, were suggested as ideal biomimetic materials for 'Functional tissue engineering' (FTE). The decellularization process comprises a compromise between damaging and preserving the ultrastructure and composition of ECM-previously shown to affect cell survival, proliferation, migration, organization, differentiation and maturation. Inversely, the effects of cells on the ECM constructs' biophysical properties, under physiological-like conditions, remain still largely unknown. We hypothesized that by re-cellularizing porcine cardiac ECM (pcECM, as a model scaffold) some of the original biophysical properties of the myocardial tissue can be restored, which are related to the scaffold's surface and the bulk modifications consequent to cellularization. We performed a systematic biophysical assessment of pcECM scaffolds seeded with human mesenchymal stem cells (MSCs), a common multipotent cell source in cardiac regenerative medicine. We report a new type of FTE study in which cell interactions with a composite-scaffold were evaluated from the perspective of their contribution to the biophysical properties of the construct surface (FTIR, WETSEM™) and bulk (DSC, TGA, and mechanical testing). The results obtained were compared with acellular pcECM and native ventricular tissue serving as negative and positive controls, respectively. MSC recellularization resulted in an inter-fiber plasticization effect, increased protein density, masking of acylated glycosaminoglycans (GAGs) and active pcECM remodelling which further stabilized the reseeded construct and increased its denaturation resistance. The systematic approach presented herein, therefore, identifies cells as "biological plasticizers" and yields important methodologies, understanding, and data serving both as a reference as well as possible 'design criteria' for future studies in FTE.
Collapse
Affiliation(s)
- Gigi Chi Ting Au-Yeung
- NTU-Technion Biomedical labs, School of Materials and Science Engineering, Nanyang Technological University, Singapore.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|