1
|
Sarfaraz S, Khan A, Hameed F, Arshad A, Mutahir Z, Zeeshan R, Ijaz K, Chaudhry AA, Khalid H, Rehman I, Khan AF. Osteogenic and antibacterial scaffolds of silk fibroin/Ce-doped ZnO for bone tissue engineering. INT J POLYM MATER PO 2022. [DOI: 10.1080/00914037.2022.2090938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Affiliation(s)
- Sehrish Sarfaraz
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Islamabad, Pakistan
- Department of Chemistry, COMSATS University Islamabad, Abbottabad, Campus Pakistan
| | - Afsar Khan
- Department of Chemistry, COMSATS University Islamabad, Abbottabad, Campus Pakistan
| | - Fareeha Hameed
- Elettra-Sincrotrone Trieste S.C.p.A, Trieste, Italy
- The ‘Abdus Salam’ International Centre for Theoretical Physics, Trieste, Italy
- Physics Department, Forman Christian College University, Lahore, Pakistan
| | - Aysha Arshad
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Islamabad, Pakistan
| | - Zeeshan Mutahir
- Institute of Biochemistry and Biotechnology, University of the Punjab, Lahore, Pakistan
| | - Rabia Zeeshan
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Islamabad, Pakistan
| | - Kashif Ijaz
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Islamabad, Pakistan
| | - Aqif Anwar Chaudhry
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Islamabad, Pakistan
| | - Hamad Khalid
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Islamabad, Pakistan
| | - Ihteshamur Rehman
- Bioengineering, Engineering Department, Lancaster University, Lancaster, UK
| | - Ather Farooq Khan
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Islamabad, Pakistan
| |
Collapse
|
2
|
Tissue Engineering in Ophthalmology: Implications for Eyelid Reconstruction. Ophthalmic Plast Reconstr Surg 2017; 33:157-162. [PMID: 27749619 DOI: 10.1097/iop.0000000000000792] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
PURPOSE Bioengineering aims to produce functional tissue replacements to repair defects and has been widely investigated over the past few decades. We aimed to review the available literature on the application of tissue engineering in ophthalmology, with a particular focus on ophthalmic plastic surgery and potential applications for eyelid reconstruction. METHODS A literature search was performed on the MEDLINE database using the keywords "bioengineering," "tissue engineering," and "ophthalmology." Articles written in English were included. RESULTS There is a substantial body of work on tissue engineering of the cornea. Other structures in ophthalmology investigated include the conjunctiva, lacrimal gland, and orbital bone. We also discuss the potential application of tissue engineering in eyelid reconstruction. CONCLUSION Tissue engineering represents the future of regenerative and reconstructive medicine, with significant potential applications in ophthalmic plastic surgery.
Collapse
|
3
|
Geven MA, Sprecher C, Guillaume O, Eglin D, Grijpma DW. Micro-porous composite scaffolds of photo-crosslinked poly(trimethylene carbonate) and nano-hydroxyapatite prepared by low-temperature extrusion-based additive manufacturing. POLYM ADVAN TECHNOL 2016. [DOI: 10.1002/pat.3890] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Mike A. Geven
- Department of Biomaterials Science and Technology, MIRA Institute for Biomedical Technology and Technical Medicine; University of Twente; Enschede Overijssel The Netherlands
| | | | | | - David Eglin
- AO Research Institute Davos; Davos Graubünden Switzerland
| | - Dirk W. Grijpma
- Department of Biomaterials Science and Technology, MIRA Institute for Biomedical Technology and Technical Medicine; University of Twente; Enschede Overijssel The Netherlands
- University of Groningen, University Medical Center Groningen, W.J. Kolff Institute; Department of Biomedical Engineering; The Netherlands
| |
Collapse
|
4
|
Salmoria G, Cardenuto M, Roesler C, Zepon K, Kanis L. PCL/Ibuprofen Implants Fabricated by Selective Laser Sintering for Orbital Repair. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.procir.2015.11.013] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
5
|
Geven MA, Varjas V, Kamer L, Wang X, Peng J, Eglin D, Grijpma DW. Fabrication of patient specific composite orbital floor implants by stereolithography. POLYM ADVAN TECHNOL 2015. [DOI: 10.1002/pat.3589] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Mike A. Geven
- MIRA Institute for Biomedical Technology and Technical Medicine; Department of Biomaterials Science and Technology; University of Twente Enschede; The Netherlands
| | | | | | - Xinjiang Wang
- Institute of Orthopaedics; Chinese People's Liberation Army General Hospital (301 Military Hospital); Beijing People's Republic of China
| | - Jiang Peng
- Institute of Orthopaedics; Chinese People's Liberation Army General Hospital (301 Military Hospital); Beijing People's Republic of China
| | | | - Dirk W. Grijpma
- MIRA Institute for Biomedical Technology and Technical Medicine; Department of Biomaterials Science and Technology; University of Twente Enschede; The Netherlands
- University of Groningen, University Medical Center Groningen, W.J. Kolff Institute; Department of Biomedical Engineering; The Netherlands
| |
Collapse
|
6
|
Geven MA, Barbieri D, Yuan H, de Bruijn JD, Grijpma DW. Preparation and mechanical properties of photo-crosslinked poly(trimethylene carbonate) and nano-hydroxyapatite composites. Clin Hemorheol Microcirc 2015; 60:3-11. [DOI: 10.3233/ch-151936] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Mike A. Geven
- MIRA Institute for Biomedical Technology and Technical Medicine, and Department of Biomaterials Science and Technology, University of Twente, Enschede, The Netherlands
| | | | - Huipin Yuan
- XPand Biotechnology BV, Bilthoven, The Netherlands
- MIRA Institute for Biomedical Technology and Technical Medicine, and Department of Tissue Regeneration, University of Twente, Enschede, The Netherlands
| | - Joost D. de Bruijn
- MIRA Institute for Biomedical Technology and Technical Medicine, and Department of Biomaterials Science and Technology, University of Twente, Enschede, The Netherlands
- XPand Biotechnology BV, Bilthoven, The Netherlands
| | - Dirk W. Grijpma
- MIRA Institute for Biomedical Technology and Technical Medicine, and Department of Biomaterials Science and Technology, University of Twente, Enschede, The Netherlands
- University of Groningen, University Medical Center Groningen, W.J. Kolff Institute, Department of Biomedical Engineering, Groningen, The Netherlands
| |
Collapse
|
7
|
Baino F, Vitale-Brovarone C. Bioceramics in ophthalmology. Acta Biomater 2014; 10:3372-97. [PMID: 24879312 DOI: 10.1016/j.actbio.2014.05.017] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2014] [Revised: 05/15/2014] [Accepted: 05/16/2014] [Indexed: 12/21/2022]
Abstract
The benefits of ceramics in biomedical applications have been universally appreciated as they exhibit an extraordinarily broad set of physico-chemical, mechanical and biological properties which can be properly tailored by acting on their composition, porosity and surface texture to increase their versatility and suitability for targeted healthcare applications. Bioceramics have traditionally been used for the repair of hard tissues, such as bone and teeth, mainly due to their suitable strength for load-bearing applications, wear resistance (especially alumina, zirconia and composites thereof) and, in some cases, bone-bonding ability (calcium orthophosphates and bioactive glasses). Bioceramics have been also applied in other medical areas, like ophthalmic surgery; although their use in such a context has been scientifically documented since the late 1700s, the potential and importance of ceramic ocular implants still seem to be underestimated and an exhaustive, critical assessment is currently lacking in the relevant literature. The present review aims to fill this gap by giving a comprehensive picture of the ceramic-based materials and implants that are currently used in ophthalmology and pointing out the strengths and weaknesses of the existing devices. A prospect for future research is also provided, highlighting the potential of new, smart bioceramics able to carry specific added values which could have a significant impact on the treatment of ocular diseases.
Collapse
|
8
|
Baino F, Perero S, Ferraris S, Miola M, Balagna C, Verné E, Vitale-Brovarone C, Coggiola A, Dolcino D, Ferraris M. Biomaterials for orbital implants and ocular prostheses: overview and future prospects. Acta Biomater 2014; 10:1064-87. [PMID: 24342039 DOI: 10.1016/j.actbio.2013.12.014] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2013] [Revised: 11/29/2013] [Accepted: 12/09/2013] [Indexed: 12/21/2022]
Abstract
The removal of an eye is one of the most difficult and dramatic decisions that a surgeon must consider in case of severe trauma or life-threatening diseases to the patient. The philosophy behind the design of orbital implants has evolved significantly over the last 60 years, and the use of ever more appropriate biomaterials has successfully reduced the complication rate and improved the patient's clinical outcomes and satisfaction. This review provides a comprehensive picture of the main advances that have been made in the development of innovative biomaterials for orbital implants and ocular prostheses. Specifically, the advantages, limitations and performance of the existing devices are examined and critically compared, and the potential of new, smart and suitable biomaterials are described and discussed in detail to outline a forecast for future research directions.
Collapse
Affiliation(s)
- Francesco Baino
- Institute of Materials Physics and Engineering, Applied Science and Technology Department, Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino, Italy.
| | - Sergio Perero
- Institute of Materials Physics and Engineering, Applied Science and Technology Department, Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino, Italy; Istituto Superiore Mario Boella, Torino, Italy
| | - Sara Ferraris
- Institute of Materials Physics and Engineering, Applied Science and Technology Department, Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino, Italy
| | - Marta Miola
- Institute of Materials Physics and Engineering, Applied Science and Technology Department, Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino, Italy
| | - Cristina Balagna
- Institute of Materials Physics and Engineering, Applied Science and Technology Department, Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino, Italy
| | - Enrica Verné
- Institute of Materials Physics and Engineering, Applied Science and Technology Department, Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino, Italy
| | - Chiara Vitale-Brovarone
- Institute of Materials Physics and Engineering, Applied Science and Technology Department, Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino, Italy
| | - Andrea Coggiola
- S.O.C. Oculistica, Azienda Ospedaliera Nazionale SS. Antonio e Biagio e Cesare Arrigo, Via Venezia 16, Alessandria, Italy
| | - Daniela Dolcino
- S.O.C. Oculistica, Azienda Ospedaliera Nazionale SS. Antonio e Biagio e Cesare Arrigo, Via Venezia 16, Alessandria, Italy
| | - Monica Ferraris
- Institute of Materials Physics and Engineering, Applied Science and Technology Department, Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino, Italy
| |
Collapse
|
9
|
Kozakiewicz M. Computer-aided orbital wall defects treatment by individual design ultrahigh molecular weight polyethylene implants. J Craniomaxillofac Surg 2013; 42:283-9. [PMID: 23835569 DOI: 10.1016/j.jcms.2013.05.015] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2012] [Revised: 05/22/2013] [Accepted: 05/23/2013] [Indexed: 10/26/2022] Open
Abstract
UNLABELLED Despite of well-known advantages of high molecular weight polyethylene (Medpor, Synpore) in orbital reconstructions, the thickness of those implants significantly exceeds 0.5 mm and precise modification of thickness is limited. The aim of this study was to present the application of a self-developed method of treatment orbital wall fracture by custom implant made of ultrahigh molecular weight polyethylene (UHMW-PE). MATERIAL AND METHOD First, the test of influence of sterilization process upon implant deformation was performed (autoclaving, ethylene oxide, gas plasma, irradiation). Next, ten cases for delayed surgical treatment of orbital fracture were included into this study (7 males, 3 females). Based on CT scan and mirrored technique, a CAD model of virtual implant for repairing orbital wall was made. Then, an implant was manufactured with a computer numerical controlled milling machine from UHMW-PE block, sterilized and used during a surgical procedure. Clinically used implants had thickness from 0.2 to 4.0 mm. RESULTS The best method of sterilization is ethylene oxide process, and the worst is autoclaving. In this series of delayed surgical cases, functional results of orbital surgery are worse than in simpler, early treated cases, but long-term subsidence of diplopia is noticeable [10% poor results]. The results of the treatment depend on the initial level of diplopia where severe initial diplopia to be corrected requires thicker implants (p < 0.01). It also leads to longer surgical procedures (p < 0.01), but prolongation of the surgery had no negative influence upon results of any investigated follow-up examinations. Obviously, the orbital destruction intensity is related to injury-evoked initial diplopia but it also influences whole results of treatment up to 12 months post-op. Interesting result is presented by the relation of maximal implant thickness to 12-month diplopia evaluation. Thicker implants used result in lower residual diplopia (p < 0.05). This is important because of the correlation between the higher orbital destruction intensity with a thicker UHMW-PE implant (p < 0.05) applied in this series. CONCLUSION Patient-specific ultrahigh molecular weight polyethylene implants enable precise reconstructions of orbital wall. One should not be afraid of a significant eye globe reposition caused by these thickness modulated implants, as such repositioning is essential for an efficient correction of enophthalmos.
Collapse
Affiliation(s)
- Marcin Kozakiewicz
- Department of Maxillofacial Surgery (Head: Marcin Kozakiewicz, DDS, PhD), Medical University of Lodz, Zeromskiego 113, Lodz, Poland.
| |
Collapse
|
10
|
Biomaterials and implants for orbital floor repair. Acta Biomater 2011; 7:3248-66. [PMID: 21651997 DOI: 10.1016/j.actbio.2011.05.016] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2011] [Revised: 04/19/2011] [Accepted: 05/16/2011] [Indexed: 11/23/2022]
Abstract
Treatment of orbital floor fractures and defects is often a complex issue. Repair of these injuries essentially aims to restore the continuity of the orbital floor and to provide an adequate support to the orbital content. Several materials and implants have been proposed over the years for orbital floor reconstruction, in the hope of achieving the best clinical outcome for the patient. Autografts have been traditionally considered as the "gold standard" choice due to the absence of an adverse immunological response, but they are available in limited amounts and carry the need for extra surgery. In order to overcome the drawbacks related to autografts, researchers' and surgeons' attention has been progressively attracted by alloplastic materials, which can be commercially produced and easily tailored to fit a wide range of specific clinical needs. In this review the advantages and limitations of the various biomaterials proposed and tested for orbital floor repair are critically examined and discussed. Criteria and guidelines for optimal material/implant choice, as well as future research directions, are also presented, in an attempt to understand whether an ideal biomaterial already exists or a truly functional implant will eventually materialise in the next few years.
Collapse
|
11
|
|
12
|
Yeatts AB, Fisher JP. Tubular perfusion system for the long-term dynamic culture of human mesenchymal stem cells. Tissue Eng Part C Methods 2010; 17:337-48. [PMID: 20929287 DOI: 10.1089/ten.tec.2010.0172] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
In vitro culture techniques must be improved to increase the feasibility of cell-based tissue engineering strategies. To enhance nutrient transport we have developed a novel bioreactor, the tubular perfusion system (TPS), to culture human mesenchymal stem cells (hMSCs) in three-dimensional scaffolds. This system utilizes an elegant design to create a more effective environment for cell culture. In our design, hMSCs in the TPS bioreactor are encapsulated in alginate beads that are tightly packed in a tubular growth chamber. The medium is perfused by a peristaltic pump through the growth chamber and around the tightly packed scaffolds enhancing nutrient transfer while exposing the cells to shear stress. Results demonstrate that bioreactor culture supports early osteoblastic differentiation of hMSCs as shown by alkaline phosphatase gene expression. After 14 and 28 days of culture significant increases in the gene expression levels of osteocalcin, osteopontin, and bone morphogenetic protein-2 were observed with bioreactor culture, and expression of these markers was shown to increase with media flow rate. These results demonstrate the TPS bioreactor as an effective means to culture hMSCs and provide insight to the effect of long-term shear stresses on differentiating hMSCs.
Collapse
Affiliation(s)
- Andrew B Yeatts
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland, USA
| | | |
Collapse
|