1
|
Microscopic characterisation of local strain field in healing tissue in the central third defect of mouse patellar tendon at early-phase of healing. J Mech Behav Biomed Mater 2021; 123:104702. [PMID: 34365097 DOI: 10.1016/j.jmbbm.2021.104702] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 06/26/2021] [Accepted: 07/03/2021] [Indexed: 11/20/2022]
Abstract
Tendons exhibit a hierarchical collagen structure, wherein higher-level components, such as collagen fibres and fascicles, are elongated, slid, and rotated during macroscopic stretching. These mechanical behaviours of collagen fibres play important roles in stimulating tenocytes, imposing stretching, compression, and shear deformation. It was hypothesised that a lack of local fibre behaviours in healing tendon tissue may result in a limited application of mechanical stimuli to cells within the tissue, leading to incomplete recovery of tissue structure and functions in regenerated tendons. Therefore, the present study aimed to measure the microscopic strain field in the healing tendon tissue. A central third defect was created in the patellar tendon of mice, and the regenerated tissue in the defect was examined by tensile testing, collagen fibre analysis, and local strain measurement using confocal microscopy at 3 and 6 weeks after surgery. Healing tissue at 3 weeks exhibited a significantly lower strength and disorganised collagen fibre structure compared with the normal tendon. These characteristics at 6 weeks remained significantly different from those of the normal tendon. Moreover, the magnitude of local shear strain in the healing tissue under 4% tissue strain was significantly smaller than that in the normal tendon. Differences in the local strain field may be reflected in the cell nuclear shape and possibly the amount of mechanical stimuli applied to the cells during tendon deformation. Accordingly, restoration of a normal local mechanical environment in the healing tissue may be key to a better healing outcome of tendon injury.
Collapse
|
2
|
Wunderli SL, Widmer J, Amrein N, Foolen J, Silvan U, Leupin O, Snedeker JG. Minimal mechanical load and tissue culture conditions preserve native cell phenotype and morphology in tendon-a novel ex vivo mouse explant model. J Orthop Res 2018; 36:1383-1390. [PMID: 28980724 DOI: 10.1002/jor.23769] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Accepted: 09/27/2017] [Indexed: 02/04/2023]
Abstract
Appropriate mechanical load is essential for tendon homeostasis and optimal tissue function. Due to technical challenges in achieving physiological mechanical loads in experimental tendon model systems, the research community still lacks well-characterized models of tissue homeostasis and physiological relevance. Toward this urgent goal, we present and characterize a novel ex vivo murine tail tendon explant model. Mouse tail tendon fascicles were extracted and cultured for 6 days in a load-deprived environment or in a custom-designed bioreactor applying low magnitude mechanical load (intermittent cycles to 1% strain, at 1 Hz) in serum-free tissue culture. Cells remained viable, as did collagen structure and mechanical properties in all tested conditions. Cell morphology in mechanically loaded tendon explants approximated native tendon, whereas load-deprived tendons lost their native cell morphology. These losses were reflected in altered gene expression, with mechanical loading tending to maintain tendon specific and matrix remodeling genes phenotypic of native tissue. We conclude from this study that ex vivo load deprivation of murine tendon in minimal culture medium results in a degenerative-like phenotype. We further conclude that onset of tissue degeneration can be suppressed by low-magnitude mechanical loading. Thus a minimal explant culture model featuring serum-free medium with low mechanical loads seems to provide a useful foundation for further investigations. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1383-1390, 2018.
Collapse
Affiliation(s)
- Stefania L Wunderli
- University Hospital Balgrist, University of Zurich, Balgrist Campus, Lengghalde 5, Zürich, CH-8008, Switzerland.,Institute for Biomechanics, ETH Zurich, Switzerland
| | - Jonas Widmer
- University Hospital Balgrist, University of Zurich, Balgrist Campus, Lengghalde 5, Zürich, CH-8008, Switzerland.,Institute for Biomechanics, ETH Zurich, Switzerland
| | - Niklaus Amrein
- University Hospital Balgrist, University of Zurich, Balgrist Campus, Lengghalde 5, Zürich, CH-8008, Switzerland.,Institute for Biomechanics, ETH Zurich, Switzerland
| | - Jasper Foolen
- University Hospital Balgrist, University of Zurich, Balgrist Campus, Lengghalde 5, Zürich, CH-8008, Switzerland.,Institute for Biomechanics, ETH Zurich, Switzerland
| | - Unai Silvan
- University Hospital Balgrist, University of Zurich, Balgrist Campus, Lengghalde 5, Zürich, CH-8008, Switzerland.,Institute for Biomechanics, ETH Zurich, Switzerland
| | - Olivier Leupin
- Novartis Institutes for BioMedical Research (NIBR), Basel, Switzerland
| | - Jess G Snedeker
- University Hospital Balgrist, University of Zurich, Balgrist Campus, Lengghalde 5, Zürich, CH-8008, Switzerland.,Institute for Biomechanics, ETH Zurich, Switzerland
| |
Collapse
|
3
|
Snedeker JG, Foolen J. Tendon injury and repair - A perspective on the basic mechanisms of tendon disease and future clinical therapy. Acta Biomater 2017; 63:18-36. [PMID: 28867648 DOI: 10.1016/j.actbio.2017.08.032] [Citation(s) in RCA: 212] [Impact Index Per Article: 30.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 08/16/2017] [Accepted: 08/25/2017] [Indexed: 12/16/2022]
Abstract
Tendon is an intricately organized connective tissue that efficiently transfers muscle force to the bony skeleton. Its structure, function, and physiology reflect the extreme, repetitive mechanical stresses that tendon tissues bear. These mechanical demands also lie beneath high clinical rates of tendon disorders, and present daunting challenges for clinical treatment of these ailments. This article aims to provide perspective on the most urgent frontiers of tendon research and therapeutic development. We start by broadly introducing essential elements of current understanding about tendon structure, function, physiology, damage, and repair. We then introduce and describe a novel paradigm explaining tendon disease progression from initial accumulation of damage in the tendon core to eventual vascular recruitment from the surrounding synovial tissues. We conclude with a perspective on the important role that biomaterials will play in translating research discoveries to the patient. STATEMENT OF SIGNIFICANCE Tendon and ligament problems represent the most frequent musculoskeletal complaints for which patients seek medical attention. Current therapeutic options for addressing tendon disorders are often ineffective, and the need for improved understanding of tendon physiology is urgent. This perspective article summarizes essential elements of our current knowledge on tendon structure, function, physiology, damage, and repair. It also describes a novel framework to understand tendon physiology and pathophysiology that may be useful in pushing the field forward.
Collapse
|
4
|
How High Glucose Levels Affect Tendon Homeostasis. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2016; 920:191-8. [PMID: 27535261 DOI: 10.1007/978-3-319-33943-6_18] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Among the many factors playing a role in tendon disease, unregulated biochemical reactions between glucose and the collagen extracellular matrix are coming increasingly into focus. We have shown that formation of advanced glycation end-products that cross-link the collagen extracellular matrix can drastically affect cellular level mechanical properties of the matrix, and in turn affect cell-level biomechanical stimuli during physiological loading of the tissue. We suggest that these may adversely affect tendon cell response to matrix damage, as well as the quality of the consequent repair. If such mechanical feedback loops are altered, the ability of tendon cells to maintain tissue in a functional, healthy state may be compromised. Although key foundational elements of biochemical, biomechanical, and biological understanding are now in place, the full extent of how these aspects interact, including the precise mechanisms by which advanced glycation end-products pathologically disrupt connective tissue homeostasis and damage repair, are only beginning to be adequately appreciated.
Collapse
|
5
|
Li Y, Würgler-Hauri CC, Schuppisser MC, Gerber C, Snedeker JG. Endoscopic functional imaging of partial tendon tears--proof of concept and intraoperative feasibility. J Biomech Eng 2013; 135:041007. [PMID: 24177265 DOI: 10.1115/1.4023702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2012] [Accepted: 02/22/2013] [Indexed: 11/08/2022]
Abstract
The ability to quantify the biomechanical integrity of tendons could provide useful information for both clinical diagnostics and for clinical follow-up in tracking functional recovery of the injured tissue. This study develops and characterizes a functional endoscopy approach for intraoperative quantification of tendon tear severity using both ex vivo and in vivo experimental models. We first verified the accuracy of endoscopic strain (i.e., tissue stretch) imaging in an ex vivo tear model by comparing endoscopic measurements against gold standard measurements with research grade optics. We then tested in vivo feasibility by endoscopically quantifying altered tissue strain distributions in a rat supraspinatus model of partial tendon tear. The endoscopic method was able to achieve diagnostically relevant levels of accuracy compared to research grade optics (mean error = 26.2 ± 19.1%), and tissue strain analysis could sensitively discern torn tendon subregions. Applying this approach to free-hand in vivo endoscopic strain measurements, we were similarly able to discern functional changes in partially torn tendons (average maximum principal strains surrounding the lesion: 5.1 ± 2.9% versus intact controls: 1.9 ± 1.4%; p = 0.023). These findings indicate that the functional endoscopic assessment of tendon mechanical integrity is not only possible but could potentially offer intraoperative arthroscopic guidance for management of tendon tears in man.
Collapse
|
6
|
Thorpe CT, Birch HL, Clegg PD, Screen HRC. The role of the non-collagenous matrix in tendon function. Int J Exp Pathol 2013; 94:248-59. [PMID: 23718692 DOI: 10.1111/iep.12027] [Citation(s) in RCA: 130] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2013] [Accepted: 04/16/2013] [Indexed: 01/26/2023] Open
Abstract
Tendon consists of highly ordered type I collagen molecules that are grouped together to form subunits of increasing diameter. At each hierarchical level, the type I collagen is interspersed with a predominantly non-collagenous matrix (NCM) (Connect. Tissue Res., 6, 1978, 11). Whilst many studies have investigated the structure, organization and function of the collagenous matrix within tendon, relatively few have studied the non-collagenous components. However, there is a growing body of research suggesting the NCM plays an important role within tendon; adaptations to this matrix may confer the specific properties required by tendons with different functions. Furthermore, age-related alterations to non-collagenous proteins have been identified, which may affect tendon resistance to injury. This review focuses on the NCM within the tensional region of developing and mature tendon, discussing the current knowledge and identifying areas that require further study to fully understand structure-function relationships within tendon. This information will aid in the development of appropriate techniques for tendon injury prevention and treatment.
Collapse
Affiliation(s)
- Chavaunne T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London E1 4NS, UK.
| | | | | | | |
Collapse
|
7
|
Li Y, Fessel G, Georgiadis M, Snedeker JG. Advanced glycation end-products diminish tendon collagen fiber sliding. Matrix Biol 2013; 32:169-77. [DOI: 10.1016/j.matbio.2013.01.003] [Citation(s) in RCA: 141] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2012] [Revised: 01/07/2013] [Accepted: 01/07/2013] [Indexed: 12/29/2022]
|
8
|
Duncan NA, Bruehlmann SB, Hunter CJ, Shao X, Kelly EJ. In situ cell-matrix mechanics in tendon fascicles and seeded collagen gels: implications for the multiscale design of biomaterials. Comput Methods Biomech Biomed Engin 2012; 17:39-47. [PMID: 23237459 DOI: 10.1080/10255842.2012.742075] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Designing biomaterials to mimic and function within the complex mechanobiological conditions of connective tissues requires a detailed understanding of the micromechanical environment of the cell. The objective of our study was to measure the in situ cell-matrix strains from applied tension in both tendon fascicles and cell-seeded type I collagen scaffolds using laser scanning confocal microscopy techniques. Tendon fascicles and collagen gels were fluorescently labelled to simultaneously visualise the extracellular matrix and cell nuclei under applied tensile strains of 5%. There were significant differences observed in the micromechanics at the cell-matrix scale suggesting that the type I collagen scaffold did not replicate the pattern of native tendon strains. In particular, although the overall in situ tensile strains in the matrix were quite similar (∼2.5%) between the tendon fascicles and the collagen scaffolds, there were significant differences at the cell-matrix boundary with visible shear across cell nuclei of >1 μm measured in native tendon which was not observed at all in the collagen scaffolds. Similarly, there was significant non-uniformity of intercellular strains with relative sliding observed between cell rows in tendon which again was not observed in the collagen scaffolds where the strain environment was much more uniform. If the native micromechanical environment is not replicated in biomaterial scaffolds, then the cells may receive incorrect or mixed mechanical signals which could affect their biosynthetic response to mechanical load in tissue engineering applications. This study highlights the importance of considering the microscale mechanics in the design of biomaterial scaffolds and the need to incorporate such features in computational models of connective tissues.
Collapse
Affiliation(s)
- Neil A Duncan
- a McCaig Institute for Bone and Joint Health, University of Calgary , 2500 University Drive, NW, Calgary AB Canada T2N 1N4
| | | | | | | | | |
Collapse
|
9
|
Human bone marrow mesenchymal stem cells: a systematic reappraisal via the genostem experience. Stem Cell Rev Rep 2011; 7:32-42. [PMID: 20198518 DOI: 10.1007/s12015-010-9125-6] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Genostem (acronym for "Adult mesenchymal stem cells engineering for connective tissue disorders. From the bench to the bed side") has been an European consortium of 30 teams working together on human bone marrow Mesenchymal Stem Cell (MSC) biological properties and repair capacity. Part of Genostem activity has been dedicated to the study of basic issues on undifferentiated MSCs properties and on signalling pathways leading to the differentiation into 3 of the connective tissue lineages, osteoblastic, chondrocytic and tenocytic. We have evidenced that native bone marrow MSCs and stromal cells, forming the niche of hematopoietic stem cells, were the same cellular entity located abluminally from marrow sinus endothelial cells. We have also shown that culture-amplified, clonogenic and highly-proliferative MSCs were bona fide stem cells, sharing with other stem cell types the major attributes of self-renewal and of multipotential priming to the lineages to which they can differentiate (osteoblasts, chondrocytes, adipocytes and vascular smooth muscle cells/pericytes). Extensive transcription profiling and in vitro and in vivo assays were applied to identify genes involved in differentiation. Thus we have described novel factors implicated in osteogenesis (FHL2, ITGA5, Fgf18), chondrogenesis (FOXO1A) and tenogenesis (Smad8). Another part of Genostem activity has been devoted to studies of the repair capacity of MSCs in animal models, a prerequisite for future clinical trials. We have developed novel scaffolds (chitosan, pharmacologically active microcarriers) useful for the repair of both bone and cartilage. Finally and most importantly, we have shown that locally implanted MSCs effectively repair bone, cartilage and tendon.
Collapse
|
10
|
Li Y, Snedeker JG. Elastography: modality-specific approaches, clinical applications, and research horizons. Skeletal Radiol 2011; 40:389-97. [PMID: 20352427 DOI: 10.1007/s00256-010-0918-0] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2010] [Revised: 02/24/2010] [Accepted: 02/24/2010] [Indexed: 02/02/2023]
Abstract
Manual palpation has been used for centuries to provide a relative indication of tissue health and disease. Engineers have sought to make these assessments increasingly quantitative and accessible within daily clinical practice. Since many of the developed techniques involve image-based quantification of tissue deformation in response to an applied force (i.e., "elastography"), such approaches fall squarely within the domain of the radiologist. While commercial elastography analysis software is becoming increasingly available for clinical use, the internal workings of these packages often remain a "black box," with limited guidance on how to usefully apply the methods toward a meaningful diagnosis. The purpose of the present review article is to introduce some important approaches to elastography that have been developed for the most widely used clinical imaging modalities (e.g., ultrasound, MRI), to provide a basic sense of the underlying physical principles, and to discuss both current and potential (musculoskeletal) applications. The article also seeks to provide a perspective on emerging approaches that are rapidly developing in the research laboratory (e.g., optical coherence tomography, fibered confocal microscopy), and which may eventually gain a clinical foothold.
Collapse
Affiliation(s)
- Yufei Li
- Department of Orthopaedics, University Hospital Balgrist, Forchstrasse 340, 8008, Zurich, Switzerland
| | | |
Collapse
|
11
|
Abstract
Stem cells always balance between self-renewal and differentiation. Hence, stem cell culture parameters are critical and need to be continuously refined according to progress in our stem cell biology understanding and the latest technological developments. In the past few years, major efforts have been made to define more precisely the medium composition in which stem cells grow or differentiate. This led to the progressive replacement of ill-defined additives such as serum or feeder cell layers by recombinant cytokines or growth factors. Another example is the control of the oxygen pressure. For many years cell cultures have been done under atmospheric oxygen pressure which is much higher than the one experienced by stem cells in vivo. A consequence of cell metabolism is that cell culture conditions are constantly changing. Therefore, the development of high sensitive monitoring processes and control algorithms is required for ensuring cell culture medium homeostasis. Stem cells also sense the physical constraints of their microenvironment. Rigidity, stiffness, and geometry of the culture substrate influence stem cell fate. Hence, nanotopography is probably as important as medium formulation in the optimization of stem cell culture conditions. Recent advances include the development of synthetic bioinformative substrates designed at the micro- and nanoscale level. On going research in many different fields including stem cell biology, nanotechnology, and bioengineering suggest that our current way to culture cells in Petri dish or flasks will soon be outdated as flying across the Atlantic Ocean in the Lindbergh's plane.
Collapse
Affiliation(s)
- Boudewijn van der Sanden
- INSERM U836, Grenoble Institut des Neurosciences, Université Joseph Fourier, CHU Michallon, 38042 Grenoble, France
| | | | | | | |
Collapse
|