1
|
Aly M, Dadak R, Lin C, Kumar K. Postoperative lingual nerve injury following airway management: A literature review. J Perioper Pract 2024:17504589241270238. [PMID: 39189112 DOI: 10.1177/17504589241270238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/28/2024]
Abstract
Postoperative lingual nerve injury is a rare but serious complication following airway management and can lead to significant discomfort and disability. This literature review explores the aetiology, clinical presentation, management strategies and potential preventive measures for lingual nerve injuries associated with airway management during surgery. A search of PubMed, MEDLINE, EMBASE Science Direct, Cochrane library and Web of Science databases was done since inception to January 2024, including any observational studies and clinical trials describing patients diagnosed with lingual nerve injury following airway instrumentation. Multiple risk factors for lingual nerve injury were identified. Anaesthesia factors include difficulty with intubation and use of laryngeal mask airway. Surgical factors are long duration of operation and surgery of the head and neck. Patient factor includes female sex. Anaesthetists should proactively inform patients about the potential for this nerve injury and control modifiable risk factors to mitigate the risk of injury.
Collapse
Affiliation(s)
- Mohamed Aly
- Schulich School of Medicine and Dentistry, The University of Western Ontario, London, ON, Canada
| | - Rohan Dadak
- Michael G. DeGroote School of Medicine, McMaster University, Hamilton, ON, Canada
| | - Cheng Lin
- Schulich School of Medicine and Dentistry, The University of Western Ontario, London, ON, Canada
- London Health Sciences Centre, London, ON, Canada
| | - Kamal Kumar
- Schulich School of Medicine and Dentistry, The University of Western Ontario, London, ON, Canada
- London Health Sciences Centre, London, ON, Canada
| |
Collapse
|
2
|
Węgiel A, Zielinska N, Głowacka M, Olewnik Ł. Hypoglossal Nerve Neuropathies-Analysis of Causes and Anatomical Background. Biomedicines 2024; 12:864. [PMID: 38672218 PMCID: PMC11048189 DOI: 10.3390/biomedicines12040864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 04/08/2024] [Accepted: 04/09/2024] [Indexed: 04/28/2024] Open
Abstract
The hypoglossal nerve is the last, and often neglected, cranial nerve. It is mainly responsible for motor innervation of the tongue and therefore the process of chewing and articulation. However, tumors, aneurysms, dissections, trauma, and various iatrogenic factors such as complications after surgeries, radiotherapy, or airway management can result in dysfunction. Correct differential diagnosis and suitable treatment require a thorough knowledge of the anatomical background of the region. This review presents the broad spectrum of hypoglossal neuropathies, paying particular attention to these with a compressive background. As many of these etiologies are not common and can be easily overlooked without prior preparation, it is important to have a comprehensive understanding of the special relations and characteristic traits of these medical conditions, as well as the most common concomitant disorders and morphological traits, influencing the clinical image. Due to the diverse etiology of hypoglossal neuropathies, specialists from many different medical branches might expect to encounter patients presenting such symptoms.
Collapse
Affiliation(s)
- Andrzej Węgiel
- Department of Anatomical Dissection and Donation, Medical University of Lodz, 90-647 Lodz, Poland; (A.W.); (N.Z.)
| | - Nicol Zielinska
- Department of Anatomical Dissection and Donation, Medical University of Lodz, 90-647 Lodz, Poland; (A.W.); (N.Z.)
| | - Mariola Głowacka
- Nursing Department, Masovian Academy in Płock, 09-402 Płock, Poland;
| | - Łukasz Olewnik
- Department of Clinical Anatomy, Masovian Academy in Płock, 09-402 Płock, Poland
| |
Collapse
|
3
|
Prim T, Brogly N, Guasch E, Díez J, Gilsanz F. Efficacy and safety of three inflation methods of the laryngeal mask airway Ambu® Auraonce™: a randomized controlled study. J Clin Monit Comput 2024; 38:37-45. [PMID: 37540323 DOI: 10.1007/s10877-023-01061-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 07/20/2023] [Indexed: 08/05/2023]
Abstract
The laryngeal mask airway (LMA) is commonly used for airway management. Cuff hyperinflation has been associated with complications, poor ventilation and increased risk of gastric insufflation. This study was designed to determine the best cuff inflation method of AuraOnce™ LMA during bronchoscopy and EBUS (Endobronquial Ultrasound Bronchoscopy) procedure. We designed a Randomized controlled, doble-blind, clinical trial to compare the efficacy and safety of three cuff inflation methods of AuraOnce™ LMA. 210 consenting patients scheduled for EBUS procedure under general anesthesia, using AuraOnce™ LMA were randomized into three groups depending on cuff insufflation: residual volume (RV), half of the maximum volume (MV), unchanged volume (NV). Parameters regarding intracuff pressure (IP), airway leak pressure (OLP), leakage volume (LV) were assessed, as well as postoperative complications (PC). 201 (95.7%) patients completed the study. Mean IP differed between groups (MV: 59.4 ± 32.4 cm H2O; RV: 75.1 ± 21.1 cm H2O; NV: 83.1 ± 25.5 cmH20; P < 0.01). The incidence of IP > 60 cmH2O was lower in the MV group compared to the other two (MV: 20/65(30.8%); RV:47/69 (68.1%); NV 48/67 (71.6%); p < 0.01). The insertion success rate was 89,6% (180/201) at first attempt, with no difference between groups (p = 0.38). No difference between groups was found either for OLP (p = 0.53), LV (p = 0.26) and PC (p = 0.16). When a cuff manometer is not available, a partial inflation of AuraOnce™ LMA cuff using MV method allows to control intracuff pressure, with no significant changes of OLP and LV compared to RV and NV insufflation method.Registration clinical trial: NCT04769791.
Collapse
Affiliation(s)
- Teresa Prim
- Department of Anesthesiology and Reanimation Surgical Intensive Care, Hospital Universitario La Paz /Cantoblanco/Carlos III, Madrid, Spain.
| | - Nicolas Brogly
- Department of Anesthesiology and Reanimation Surgical Intensive Care, Hospital Universitario La Paz /Cantoblanco/Carlos III, Madrid, Spain
| | - Emilia Guasch
- Department of Anesthesiology and Reanimation Surgical Intensive Care, Hospital Universitario La Paz /Cantoblanco/Carlos III, Madrid, Spain
| | - Jesús Díez
- Department of Biostatistics, Hospital Universitario La Paz, Pº de la Castellana, 261, Madrid, 28046, Spain
| | - Fernando Gilsanz
- Department of Surgery, Universidad Autónoma de Madrid, Calle del Arzobispo Morcillo, 4, Madrid, 28029, Spain
| |
Collapse
|
4
|
Sotis CL, Jafari H, Solano JJ, Fishman I. Transient Hypoglossal and Lingual Nerve Injury Following the Use of I-gel Supraglottic Airway: A Case Report. Cureus 2023; 15:e47509. [PMID: 38021847 PMCID: PMC10664044 DOI: 10.7759/cureus.47509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/23/2023] [Indexed: 12/01/2023] Open
Abstract
Injury to the hypoglossal and/or lingual nerve is a rare occurrence with the use of a laryngeal mask airway (LMA) or supraglottic airway (SGA) device. There has been one prior report of a lingual and hypoglossal nerve injury with the i-gel™ SGA. We are describing the second reported hypoglossal and lingual transient nerve injury in a male patient while using an i-gel™ SGA. Although excessive cuff pressure has been cited as a possible cause, the i-gel™ does not have a cuff. This report highlights that hypoglossal nerve injury can still occur, even with the use of a cuffless LMA such as the i-gel™ SGA.
Collapse
Affiliation(s)
- Claudia L Sotis
- Surgical Services, West Palm Beach Veterans Affairs Medical Center, West Palm Beach, USA
| | - Hosseinali Jafari
- Surgical Services, West Palm Beach Veterans Affairs Medical Center, West Palm Beach, USA
| | - Joshua J Solano
- Emergency Medicine, Florida Atlantic University, Boca Raton, USA
| | - Irina Fishman
- Surgical Services, West Palm Beach Veterans Affairs Medical Center, West Palm Beach, USA
| |
Collapse
|
5
|
Castillo-Monzón CG, Gaszyński T, Marroquín-Valz HA, Orozco-Montes J, Ratajczyk P. Supraglottic Airway Devices with Vision Guided Systems: Third Generation of Supraglottic Airway Devices. J Clin Med 2023; 12:5197. [PMID: 37629238 PMCID: PMC10455808 DOI: 10.3390/jcm12165197] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 07/31/2023] [Accepted: 08/05/2023] [Indexed: 08/27/2023] Open
Abstract
Supraglottic airway devices are currently widely used for airway management both for anaesthesia and emergency medicine. First-generation SADs only had a ventilation channel and did not provide protection from possible aspiration of gastric content if regurgitation occurred. Second-generation SADs are equipped with a gastric channel to allow the insertion of a gastric catheter and suctioning of gastric content. Additionally, the seal was improved by a change in the shape of the cuff. Some second-generation SADs were also designed to allow for intubation through the lumen using fiberscopes. Although the safety and efficacy of use of SADs are very high, there are still some issues in terms of providing an adequate seal and protection from possible complications related to misplacement of SAD. New SADs which allow users to choose the insertion scope and control the position of SAD can overcome those problems. Additionally, the Video Laryngeal Mask Airway may serve as an endotracheal intubation device, offering a good alternative to fibre-optic intubation through second-generation SADs. In this narrative review, we provide knowledge of the use of video laryngeal mask airways and the possible advantages of introducing them into daily clinical practice.
Collapse
Affiliation(s)
- Caridad G. Castillo-Monzón
- Service of Anaesthesiology, Reanimation and Pain Therapy, University General Hospital of Cartagena, 30202 Murcia, Spain;
| | - Tomasz Gaszyński
- Department of Anaesthesiology and Intensive Therapy, Medical University of Lodz, 90-154 Lodz, Poland;
| | | | - Javier Orozco-Montes
- Service of Anaesthesiology, Reanimation and Pain Therapy, University General Hospital of Cartagena, 30202 Murcia, Spain;
| | - Pawel Ratajczyk
- Department of Anaesthesiology and Intensive Therapy, Medical University of Lodz, 90-154 Lodz, Poland;
| |
Collapse
|
6
|
Xian L, Yuan J, Li H, Gao Z, He J, Deng H. Unilateral sublingual nerve paralysis after laryngeal mask airway in a patient with congenital heart disease: a case report. J Int Med Res 2023; 51:3000605231190899. [PMID: 37561563 PMCID: PMC10416657 DOI: 10.1177/03000605231190899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Accepted: 07/10/2023] [Indexed: 08/11/2023] Open
Abstract
Laryngeal masks are widely used by anesthesiologists in clinical practice because of their advantages of no tracheal injury, minimal airway stimulation, limited airway tissue invasion, and easy implantation and airway establishment. We herein describe a patient with congenital heart disease who developed unilateral sublingual nerve paralysis after application of a laryngeal mask airway. The patient reported perioral numbness and exhibited unclear speech and slight right deviation of the tip of the tongue after surgery. On physical examination, the patient had normal muscle strength, symmetrical frontal lines, normal occlusion, and a normal nasolabial groove. We performed head computed tomography and computed tomography angiography to rule out cerebrovascular disease, and no abnormalities were found. The patient's imaging findings and clinical symptoms suggested unilateral right sublingual nerve palsy. After active treatment, the patient's symptoms improved by 75% on the third postoperative day and by 90% on the fifth postoperative day. Despite the extremely low incidence of sublingual nerve palsy after application of a laryngeal mask airway, anesthesiologists should be aware of this complication. Although the nerve palsy can resolve spontaneously, the nerve damage may be permanent.
Collapse
Affiliation(s)
- Li Xian
- Department of Anesthesiology, No. 363 Hospital, Sichuan Province, Chengdu, China
| | - Jinlong Yuan
- Department of Anesthesiology, No. 363 Hospital, Sichuan Province, Chengdu, China
| | - Hong Li
- Department of Anesthesiology, No. 363 Hospital, Sichuan Province, Chengdu, China
| | - Zhiyong Gao
- Department of Anesthesiology, No. 363 Hospital, Sichuan Province, Chengdu, China
| | - Jing He
- Department of Nursing, No. 363 Hospital, Sichuan Province, Chengdu, China
| | - Haijun Deng
- Department of Nursing, No. 363 Hospital, Sichuan Province, Chengdu, China
| |
Collapse
|
7
|
Shah V, Sharma KS, Kulkarni AP. Does Baska mask deserve its own niche among extraglottic airway devices? A prospective, single-arm study. Indian J Anaesth 2023; 67:603-608. [PMID: 37601937 PMCID: PMC10436717 DOI: 10.4103/ija.ija_997_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 07/10/2022] [Accepted: 03/26/2023] [Indexed: 08/22/2023] Open
Abstract
Background and Aims A variety of extraglottic airway devices (EADs) are available. Main concerns with EADs are protection against aspiration and ability to ventilate patients with high airway pressures. Baska mask meets these criteria and is the only third-generation device available for clinical use. Methods After institutional ethics committee approval and informed consent were obtained, this prospective study was performed in 100 adult patients undergoing surface surgeries at a tertiary referral centre. The primary outcome was the success rate of insertion, while the secondary outcomes were the sealing pressure, stability of the device and the perioperative complications of Baska mask. We then compared it with other currently used EADs. Results The first attempt at insertion and overall success rates, showed values of 81% and 98%, respectively. Insertion was quick (median 12; interquartile range [IQR] 9-15 s). The mask sealing pressure, was 35 cmH2O (median [IQR 20-50 cmH2O]). Also, the mask remained stable in 95% of patients intraoperatively. Sore throat and dysphagia were seen in 37% and 24% of patients, respectively. No patient had laryngospasm or desaturation at any time. It compared favourably well with other EADs, while achieving higher sealing pressures. Conclusion We found that the Baska mask performs well with excellent first attempt at insertion and overall success rates, higher sealing pressures and minimal complications compared to currently used EADs in clinical anaesthesia.
Collapse
Affiliation(s)
- Vinisha Shah
- Department of Anaesthesia, NH-SRCC Children’s Hospital, Mumbai, Maharashtra, India
| | - Kailash S. Sharma
- Department of Anaesthesia, Critical Care and Pain, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai Maharashtra, India
| | - Atul P. Kulkarni
- Division of Critical Care Medicine, Department of Anaesthesia, Critical Care and Pain, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, Maharashtra, India
| |
Collapse
|
8
|
Gómez-Ríos MÁ, López T, Sastre JA, Gaszyński T, Van Zundert AAJ. Video laryngeal masks in airway management. Expert Rev Med Devices 2022; 19:847-858. [DOI: 10.1080/17434440.2022.2142558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Affiliation(s)
- Manuel Á. Gómez-Ríos
- Anesthesiology and Perioperative Medicine. Complejo Hospitalario Universitario de A Coruña, Galicia, Spain
| | - Teresa López
- Anesthesiology and Perioperative Medicine. Complejo Asistencial Universitario de Salamanca, Salamanca, Spain
| | - José Alfonso Sastre
- Anesthesiology and Perioperative Medicine. Complejo Asistencial Universitario de Salamanca, Salamanca, Spain
| | - Tomasz Gaszyński
- Department of Anesthesiology and Intensive Therapy Medical University of Lodz, Poland
| | - André A. J. Van Zundert
- Professor & Chairman Discipline of Anesthesiology, The University of Queensland
- Faculty of Medicine & Biomedical Sciences, Brisbane, QLD, Australia
- Chair, University of Queensland Burns, Trauma & Critical Care Research Centre
- Chair, RBWH/University of Queensland Centre for Excellence & Innovation in Anaesthesia
| |
Collapse
|
9
|
Wang ZY, Liu WZ, Wang FQ, Chen YZ, Huang T, Yuan HS, Cheng Y. Lingual nerve injury caused by laryngeal mask airway during percutaneous nephrolithotomy: A case report. World J Clin Cases 2021; 9:11095-11101. [PMID: 35047623 PMCID: PMC8678870 DOI: 10.12998/wjcc.v9.i35.11095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Revised: 08/07/2021] [Accepted: 10/27/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Lingual nerve injury (LNI) is a rare complication following the use of laryngeal mask airway (LMA). The occurrence of this unexpected complication causes uncomfortable symptoms in patients and worsens their quality of life. We present an unusual case of LNI caused by the use of an LMA in percutaneous nephrolithotomy (PCNL).
CASE SUMMARY A 49-year-old man presented to our hospital with a 3-year history of intermittent left lower back pain. Abdominal computed tomography showed a 25 mm × 20 mm stone in the left renal pelvis. PCNL surgery using LMA was performed to remove the renal stone. The patient reported numbness on the tip of his tongue after the operation, but there were no signs of swelling or trauma. The patient was diagnosed with LNI after other possible causes were ruled out. The symptom of numbness eventually improved after conservative medical therapy for 1 wk. The patient completely recovered 3 wk after surgery.
CONCLUSION This is the first case report describing LNI with the use of LMA in PCNL. In our case, an inappropriate LMA size, intraoperative movement, and a specific surgical position might be potential causes of this rare complication.
Collapse
Affiliation(s)
- Zheng-Yi Wang
- Medical College, Ningbo University, Ningbo 315211, Zhejiang Province, China
| | - Wan-Zhang Liu
- Department of Urology, Ningbo First Hospital, The Affiliated Hospital of Ningbo University, Ningbo 315010, Zhejiang Province, China
| | - Feng-Qi Wang
- Medical College, Ningbo University, Ningbo 315211, Zhejiang Province, China
| | - Ying-Zhi Chen
- Medical College, Ningbo University, Ningbo 315211, Zhejiang Province, China
| | - Ting Huang
- Department of Urology, Ningbo First Hospital, The Affiliated Hospital of Ningbo University, Ningbo 315010, Zhejiang Province, China
| | - He-Sheng Yuan
- Department of Urology, Ningbo First Hospital, The Affiliated Hospital of Ningbo University, Ningbo 315010, Zhejiang Province, China
| | - Yue Cheng
- Department of Urology, Ningbo First Hospital, The Affiliated Hospital of Ningbo University, Ningbo 315010, Zhejiang Province, China
| |
Collapse
|
10
|
Wang MH, Zhang DS, Zhou W, Tian SP, Zhou TQ, Sui W, Zhang Z. Effects of Peak Inspiratory Pressure-Guided Setting of Intracuff Pressure for Laryngeal Mask Airway Supreme™ Use during Laparoscopic Cholecystectomy: A Randomized Controlled Trial. J INVEST SURG 2020; 34:1137-1144. [PMID: 32354298 DOI: 10.1080/08941939.2020.1761487] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
PURPOSE To determine the effects of peak inspiratory pressure (PIP)-guided intracuff pressure (ICP) modulation of laryngeal mask airway (LMA) Supreme™ during laparoscopic cholecystectomy. METHODS Totally 120 patients were randomly divided using computer-generated numbers into a control group (n = 60; ICP, 60 cmH2O) and a PIP group (n = 60), in which ICP was increased with 5 cmH2O each time from PIP level until no air leaks from the oropharynx. PIP, ICP, cuff volume (CV), oropharyngeal leak pressure (OLP) and leak fraction (LF) were recorded before and after pneumoperitoneum establishment. Postoperative pharyngolaryngeal complications (sore throat, dysphagia, pharyngeal hematoma, and dysphonia) were also recorded. RESULTS Demographic data were similar in the two groups. The CV and ICP before and after pneumoperitoneum were significantly lower in the PIP group (CV: 15.6 ± 2.3 mL and 21.0 ± 2.6 mL; ICP: 14.3 ± 2.9 cmH2O and 20.5 ± 3.4 cmH2O) than in the control group (CV: 33.0 ± 2.8 mL and 32.8 ± 1.9 mL; ICP: 60.0 ± 0.1 cmH2O and 60.0 ± 0.1 cmH2O) (P < 0.05). Although OLP was lower in the PIP group (P < 0.05), the LF was similar in the two groups (P > 0.05). There were fewer postoperative pharyngolaryngeal complications in the PIP group (P < 0.05). CONCLUSIONS Compared with a fixed ICP of 60 cmH2O, PIP-guided ICP modulation during LMA Supreme™ use provided effective airway sealing at a lower CV and ICP, and produced fewer postoperative pharyngolaryngeal complications in patients undergoing laparoscopic cholecystectomy.
Collapse
Affiliation(s)
- Mao-Hua Wang
- Department of Anesthesiology, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, China
| | - Dong-Sheng Zhang
- Department of Anesthesiology, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, China
| | - Wei Zhou
- Department of Anesthesiology, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, China
| | - Shun-Ping Tian
- School of Medicine, Yangzhou University, Yangzhou, China
| | - Tian-Qi Zhou
- Preventive Health Care Office, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, China
| | - Wei Sui
- Department of Anesthesiology, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, China
| | - Zhuan Zhang
- Department of Anesthesiology, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, China
| |
Collapse
|
11
|
Yoo S, Park SK, Kim WH, Hur M, Bahk JH, Lim YJ, Kim JT. Influence of head and neck position on performance of the Ambu® AuraGain™ laryngeal mask: a randomized crossover study. Minerva Anestesiol 2019; 85:133-138. [DOI: 10.23736/s0375-9393.18.12579-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
12
|
Ipsilateral hypoglossal nerve palsy following left hemithyroidectomy: Case report and review of literature. Int J Surg Case Rep 2018; 51:5-7. [PMID: 30121396 PMCID: PMC6098235 DOI: 10.1016/j.ijscr.2018.07.044] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2018] [Accepted: 07/30/2018] [Indexed: 11/20/2022] Open
Abstract
INTRODUCTION Hypoglossal nerve palsy (HNP) is a rare complication of airway management. Multiple factors have been postulated to contribute to its occurrence. Herein, we present a case of ipsilateral HNP following left hemithyroidectomy. CASE PRESENTATION A 47-year-old women presented complaining of left thyroid swelling for 1 year with no symptoms of compression or hormonal impairment. Ultrasound of the neck showed a 3 × 2 cm nodule in the left thyroid lobe without lymphadenopathy. Fine-needle aspiration revealed a follicular neoplasm. Left hemithyroidectomy was carried out uneventfully. Three hours postoperatively, the patient started to complaint of dysarthria, dysphagia and odynophagia with clinical sign of tongue deviation to the left side. Head and neck CT ruled out mass effect or ischemic event, and the diagnosis of left HNP was established. Four months postoperatively, the palsy was completely resolved. Histopathology examination of the thyroid nodule showed follicular adenoma, and no further intervention was provided. DISCUSSION Few cases of HNP are reported in the literature following oropharyngeal manipulation. Factors such as the type of surgery, position changes, and intubation characteristics have been linked to the incidence of HNP. Most of the cases recovered spontaneously, indicating a neuro-paxic type of injury. One case of HNP was reported following robotic total thyroidectomy, which was referred to as iatrogenic complication, and resulted in permanent paralysis. We believe that our case is the only reported case of transient ipsilateral HNP following a conventional left hemithyroidectomy. CONCLUSION Strap muscles retraction and neck extension during thyroidectomy could predispose to HNP.
Collapse
|
13
|
Garg J, Liew GHC, Khan SA. Greater palatine nerve neuropraxia after laryngeal mask insertion: A rare occurrence. Indian J Anaesth 2017; 61:930-932. [PMID: 29217860 PMCID: PMC5703008 DOI: 10.4103/ija.ija_364_17] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
With the more frequent use of the laryngeal mask airway (LMA) over endotracheal tubes for general anaesthesia, various cranial nerve injuries have been reported recently. We report a rare occurrence of greater palatine nerve (GPN) palsy subsequent to the use of LMA Supreme™ in a young female scheduled for hand surgery. Although the exact mechanism of a nerve injury is still a matter of further research, we postulate pressure neuropraxia of GPN as a causative factor in the development of numbness over the hard palate after the removal of LMA in the post operative period.
Collapse
Affiliation(s)
- Jyoti Garg
- Department of Anesthesia and Intensive Care, Sengkang General Hospital, Singapore
| | | | - Shariq Ali Khan
- Department of Anesthesia and Intensive Care, Singapore General Hospital, Singapore
| |
Collapse
|
14
|
|
15
|
Ueshima H, Okumura N, Otake H. Lingual nerve palsy after i-gel ® use. J Anesth 2016; 30:1095. [PMID: 27535141 DOI: 10.1007/s00540-016-2239-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2016] [Accepted: 08/12/2016] [Indexed: 02/07/2023]
Affiliation(s)
- Hironobu Ueshima
- Department of Anesthesiology, Showa University Hospital, Tokyo, Japan.
| | - Noriko Okumura
- Department of Anesthesiology, Showa University Hospital, Tokyo, Japan
| | - Hiroshi Otake
- Department of Anesthesiology, Showa University Hospital, Tokyo, Japan
| |
Collapse
|
16
|
Li BB, Yan J, Zhou HG, Hao J, Liu AJ, Ma ZL. Application of Minimum Effective Cuff Inflating Volume for Laryngeal Mask Airway and its Impact on Postoperative Pharyngeal Complications. Chin Med J (Engl) 2016; 128:2570-6. [PMID: 26415792 PMCID: PMC4736869 DOI: 10.4103/0366-6999.166034] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND High intracuff pressure can cause severe pharyngeal complications including sore throat or hoarseness after laryngeal mask airway (LMA) removal postoperatively. Though the application of minimum effective cuff inflating volume is suggested to maintain airway sealing and adequacy of ventilation for patients receiving general anesthesia with LMA at lower level of the intracuff pressure, it is currently not a standard care in most of the anesthetic departments. In this study, the minimum effective cuff inflating volume was determined for classic LMA Well Lead™ (Well Lead Medical Co., Ltd., China) and its impact on postoperative pharyngeal complications was also explored. METHODS Patients with American Society of Anesthesiologists physical status (I-III) undergoing the short-duration urological surgery were recruited in this trial. First, the minimum effective cuff inflating volume was determined for size 4 or 5 LMA Well Lead in the study 1. Immediately following placement and confirmation of ideal LMA position, the cuff was inflated with 5, 7, 10 ml of air and up to 30 ml at 5 ml increment. The intracuff pressure, oropharyngeal leak pressure (OLP), and inspiratory peak airway pressure under positive pressure ventilation at the corresponding cuff volume as indicated above were recorded. Second, the enrolled patients were randomly allocated into minimum effective cuff inflating volume group (MC) and routine care (RC) group in the study 2. The minimum effective cuff inflating volume was applied and maintained in MC group, whereas the cuff volume was inflated with half of the maximum cuff inflating volume recommended by manufacturer in RC group throughout the surgical procedure and stay in postanesthesia care unit prior to LMA removal. The incidence of pharyngeal complications at 0, 2, 24, and 48 h after removal of LMA and other intra-operative adverse events were also documented. RESULTS The intracuff pressure varied with the cuff inflating volume in a positive linear correlation manner (Y = 11.68X - 42.1, r(2) = 0.9191) under the range of 5-30 ml for size 4 LMA. In similar with size 4 LMA, the data were also showed the linear relationship between the intracuff pressure and the cuff inflating volume (Y = 7.39X - 10.9, r(2) = 0.8855) for size 5 LMA. The minimal effective cuff inflating volume for size 4 or 5 LMA was 7-9 ml in combination of considering OLP needed to maintain airway sealing during intermittently positive pressure ventilation. The intracuff pressure in MC group was lower compared with RC group (63.0 ± 3.7 vs. 126.4 ± 24.0 cmH2O for size 4 LMA; 55.6 ± 2.4 vs. 138.5± 26.8 cmH2O for size 5 LMA; P < 0.0001). The incidence of pharyngeal adverse events was lower in MC group versus the RC group at 2, 24 h after LMA removal. CONCLUSIONS The relationship between the cuff inflating volume and the intracuff pressure for size 4 or 5 LMA Well Lead(TM) is in a linear correlation manner at the range of 5-30 ml. The minimal cuff inflating volume is adequate for satisfactory airway sealing and consequently associated with lower incidence of postoperative pharyngeal complications for LMA Well Lead.™.
Collapse
Affiliation(s)
| | | | | | | | | | - Zheng-Liang Ma
- Department of Anesthesiology, The Affiliated Drum Tower Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu 210008, China
| |
Collapse
|
17
|
Comparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study. Anesthesiol Res Pract 2015; 2015:971059. [PMID: 26697064 PMCID: PMC4678238 DOI: 10.1155/2015/971059] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2015] [Revised: 11/13/2015] [Accepted: 11/17/2015] [Indexed: 11/17/2022] Open
Abstract
Introduction. This study compared streamlined liner of the pharynx airway (SLIPA) and I-gel noninflatable, single-use, supraglottic airway device (SAD) performance in anesthetized, paralyzed adults. Methods. Eighty adults (ASA physical statuses I–III) who were undergoing elective procedures under general anesthesia with an SAD were enrolled in this prospective, randomized, single-blind study. Subjects were randomly and evenly assigned to the SLIPA or I-gel group for intraoperative airway management. Ease and number of insertions, insertion time, oropharyngeal sealing pressure, hemodynamic response, oxygen saturation (SpO2), end-tidal CO2 (EtCO2), and peri- and postoperative complications were examined. Results. The SLIPA and I-gel devices were successfully inserted in 100% and 95% of subjects, respectively. In two I-gel subjects (5%), ventilation was not possible after two attempts, but a size 55 SLIPA was successfully inserted in both cases. Forty-two and 38 patients were ultimately included in the SLIPA and I-gel groups, respectively. Insertion time was significantly shorter with the SLIPA (11.19 ± 3.03 s) than with the I-gel (15.05 ± 6.37 s, P = 0.003). Oropharyngeal sealing pressure was significantly higher in SLIPA (28.76 ± 3.11 cmH2O) than in I-gel (25.9 ± 3.65 cmH2O) subjects (P = 0.001). Blood staining occurred more frequently in SLIPA (n = 8, 19.0%) than in I-gel (n = 5, 13.2%) patients (P < 0.01). Heart rate, mean arterial blood pressure, SpO2, and EtCO2 were not significantly different between groups. Conclusion. Although blood staining incidence was higher, SLIPA insertion was easier and faster than I-gel insertion. The SLIPA provided better airway sealing pressure. Both devices had similar mechanical ventilation and oxygenation characteristics and comparable hemodynamic stability. Both noninflatable SADs are useful, but SLIPA rapid insertion and good airway sealing make it an effective alternative to the I-gel.
Collapse
|
18
|
Yurtlu BS, Hanci V, Köksal B, Okyay D, Ayoğlu H, Turan IÖ. [Impact of the practising anesthesiologist team member on the laryngeal mask cuff pressures and adverse event rate]. Rev Bras Anestesiol 2015; 65:455-60. [PMID: 26655709 DOI: 10.1016/j.bjan.2013.03.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2012] [Accepted: 03/20/2013] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVE We have planned to evaluate the laryngeal mask cuff pressures (LMcp) inflated by anesthesia workers of several seniority, without using manometer. METHODS 180 patients scheduled to have short duration surgery with laryngeal mask were included in the study. Five anesthesia specialists (Group S), 10 residents (Group R) and 6 technicians (Group T) inflated the LMc; thereafter LMcp were measured with pressure manometer. Participants have repeated this practice in at least five different cases. LMcp higher than 60cm H2O at the initial placement or intraoperative period were adjusted to normal range. Sore throat was questioned postoperatively. Groups were compared in terms of mean LMcp and occupational experience. RESULTS At the settlement of LM, LMcp pressures within the normal range were determined in 26 (14.4%) cases. Mean LMcp after LM placement in Group S, R and T were 101.2±14.0, 104.3±20.5cm H2O and 105.2±18.4cm H2O respectively (p>0.05). Mean LMcp values in all measurement time periods within the groups were above the normal limit (60cm H2O). When groups were compared in terms of LMcp, no difference has been found among pressure values. Occupational experience was 14.2±3.9; 3.3±1.1 and 6.6±3.8 years for specialists, residents and technicians respectively and measured pressure values were not different in regard of occupational experience. Seven (3.9%) patients had sore throat at the 24th hour interview. CONCLUSION Considering lower possibility of normal adjustment of LMcp and ineffectiveness of occupational experience to obtain normal pressure values, it is suitable that all anesthesia practitioners should adjust LMcp with manometer.
Collapse
Affiliation(s)
- Bülent Serhan Yurtlu
- Departamento de Anestesia e Reanimação, Faculdade de Medicina, Zonguldak Karaelmas University, Zonguldak, Turquia.
| | - Volkan Hanci
- Departamento de Anestesia e Reanimação, Faculdade de Medicina, Zonguldak Karaelmas University, Zonguldak, Turquia
| | - Bengü Köksal
- Departamento de Anestesia e Reanimação, Faculdade de Medicina, Zonguldak Karaelmas University, Zonguldak, Turquia
| | - Dilek Okyay
- Departamento de Anestesia e Reanimação, Faculdade de Medicina, Zonguldak Karaelmas University, Zonguldak, Turquia
| | - Hilal Ayoğlu
- Departamento de Anestesia e Reanimação, Faculdade de Medicina, Zonguldak Karaelmas University, Zonguldak, Turquia
| | - Işıl Özkoçak Turan
- Departamento de Anestesia e Reanimação, Faculdade de Medicina, Zonguldak Karaelmas University, Zonguldak, Turquia
| |
Collapse
|
19
|
Michalek P, Donaldson W, Vobrubova E, Hakl M. Complications Associated with the Use of Supraglottic Airway Devices in Perioperative Medicine. BIOMED RESEARCH INTERNATIONAL 2015; 2015:746560. [PMID: 26783527 PMCID: PMC4691459 DOI: 10.1155/2015/746560] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2015] [Accepted: 11/24/2015] [Indexed: 12/15/2022]
Abstract
Supraglottic airway devices are routinely used for airway maintenance in elective surgical procedures where aspiration is not a significant risk and also as rescue devices in difficult airway management. Some devices now have features mitigating risk of aspiration, such as drain tubes or compartments to manage regurgitated content. Despite this, the use of these device may be associated with various complications including aspiration. This review highlights the types and incidence of these complications. They include regurgitation and aspiration of gastric contents, compression of vascular structures, trauma, and nerve injury. The incidence of such complications is quite low, but as some carry with them a significant degree of morbidity the need to follow manufacturers' advice is underlined. The incidence of gastric content aspiration associated with the devices is estimated to be as low as 0.02% with perioperative regurgitation being significantly higher but underreported. Other serious, but extremely rare, complications include pharyngeal rupture, pneumomediastinum, mediastinitis, or arytenoid dislocation. Mild short-lasting adverse effects of the devices have significantly higher incidence than serious complications and involve postoperative sore throat, dysphagia, pain on swallowing, or hoarseness. Devices may have deleterious effect on cervical mucosa or vasculature depending on their cuff volume and pressure.
Collapse
Affiliation(s)
- Pavel Michalek
- Department of Anaesthesia and Intensive Medicine, 1st Medical Faculty, Charles University in Prague and General University Hospital, U Nemocnice 2, 120 21 Prague, Czech Republic
- University of East Anglia, Norwich Research Park, Norwich, Norfolk NR4 7TJ, UK
| | - William Donaldson
- Department of Anaesthetics, Antrim Area Hospital, Bush Road, Antrim BT41 4RD, UK
| | - Eliska Vobrubova
- Department of Anaesthesia and Intensive Medicine, 1st Medical Faculty, Charles University in Prague and General University Hospital, U Nemocnice 2, 120 21 Prague, Czech Republic
| | - Marek Hakl
- Department of Anaesthesia and Intensive Medicine, St. Anne University Hospital, Pekarska 53, 656 91 Brno, Czech Republic
| |
Collapse
|
20
|
Yurtlu BS, Hanci V, Köksal B, Okyay D, Ayoğlu H, Turan IÖ. Impact of the practising anesthesiologist team member on the laryngeal mask cuff pressures and adverse event rate. Braz J Anesthesiol 2015; 65:455-60. [PMID: 26614141 DOI: 10.1016/j.bjane.2013.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2012] [Accepted: 03/20/2013] [Indexed: 11/25/2022] Open
Abstract
OBJECTIVE We have planned to evaluate the laryngeal mask cuff pressures (LMcp) inflated by anesthesia workers of several seniority, without using manometer. METHODS 180 patients scheduled to have short duration surgery with laryngeal mask were included in the study. Five anesthesia specialists (Group S), 10 residents (Group R) and 6 technicians (Group T) inflated the LMc; thereafter LMcp were measured with pressure manometer. Participants have repeated this practice in at least five different cases. LMcp higher than 60 cm H2O at the initial placement or intraoperative period were adjusted to normal range. Sore throat was questioned postoperatively. Groups were compared in terms of mean LMcp and occupational experience. RESULTS At the settlement of LM, LMcp pressures within the normal range were determined in 26 (14.4%) cases. Mean LMcp after LM placement in Group S, R and T were 101.2 ± 14.0, 104.3 ± 20.5 cm H2O and 105.2 ± 18.4 cm H2O respectively (p > 0.05). Mean LMcp values in all measurement time periods within the groups were above the normal limit (60 cm H2O). When groups were compared in terms of LMcp, no difference has been found among pressure values. Occupational experience was 14.2 ± 3.9; 3.3 ± 1.1 and 6.6 ± 3.8 years for specialists, residents and technicians respectively and measured pressure values were not different in regard of occupational experience. Seven (3.9%) patients had sore throat at the 24th hour interview. CONCLUSION Considering lower possibility of normal adjustment of LMcp and ineffectiveness of occupational experience to obtain normal pressure values, it is suitable that all anesthesia practitioners should adjust LMcp with manometer.
Collapse
Affiliation(s)
- Bülent Serhan Yurtlu
- Anesthesiology and Reanimation Department, Faculty of Medicine, Zonguldak Karaelmas University, Zonguldak, Turkey.
| | - Volkan Hanci
- Anesthesiology and Reanimation Department, Faculty of Medicine, Zonguldak Karaelmas University, Zonguldak, Turkey
| | - Bengü Köksal
- Anesthesiology and Reanimation Department, Faculty of Medicine, Zonguldak Karaelmas University, Zonguldak, Turkey
| | - Dilek Okyay
- Anesthesiology and Reanimation Department, Faculty of Medicine, Zonguldak Karaelmas University, Zonguldak, Turkey
| | - Hilal Ayoğlu
- Anesthesiology and Reanimation Department, Faculty of Medicine, Zonguldak Karaelmas University, Zonguldak, Turkey
| | - Işıl Özkoçak Turan
- Anesthesiology and Reanimation Department, Faculty of Medicine, Zonguldak Karaelmas University, Zonguldak, Turkey
| |
Collapse
|
21
|
Abstract
The professional singer comes to the day of surgery with a measure of anxiety about the effects of anesthesia or surgery on his or her voice. A detailed informed consent should be obtained to discuss and document risks, as well as set realistic expectations for recovery. The smallest endotracheal tube possible should be used to intubate in the least traumatic way. Movement of the tube should be minimized, both during anesthesia, as well as in emergence. Postoperative care may be coordinated with an otolaryngologist and speech language pathologist as the singer plans a return to performance.
Collapse
Affiliation(s)
- Ryan K Meacham
- Department of Otolaryngology, Oregon Health Sciences University, Portland, OR, USA.
| | - Joshua Schindler
- Department of Otolaryngology, Oregon Health Sciences University, Portland, OR, USA
| |
Collapse
|
22
|
Shah AC, Barnes C, Spiekerman CF, Bollag LA. Hypoglossal nerve palsy after airway management for general anesthesia: an analysis of 69 patients. Anesth Analg 2015; 120:105-120. [PMID: 25625257 DOI: 10.1213/ane.0000000000000495] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Isolated hypoglossal nerve palsy (HNP), or neurapraxia, a rare postoperative complication after airway management, causes ipsilateral tongue deviation, dysarthria, and dysphagia. We reviewed the pathophysiological causes of hypoglossal nerve injury and discuss the associated clinical and procedural characteristics of affected patients. Furthermore, we identified procedural factors potentially affecting HNP recovery duration and propose several measures that may reduce the risk of HNP. While HNP can occur after a variety of surgeries, most cases in the literature were reported after orthopedic and otolaryngology operations, typically in males. The diagnosis is frequently missed by the anesthesia care team in the recovery room due to the delayed symptomatic onset and often requires neurology and otolaryngology evaluations to exclude serious etiologies. Signs and symptoms are self-limited, with resolution occurring within 2 months in 50% of patients, and 80% resolving within 4 months. Currently, there are no specific preventive or therapeutic recommendations. We found 69 cases of HNP after procedural airway management reported in the literature from 1926 to 2013.
Collapse
Affiliation(s)
- Aalap C Shah
- From the Department of Anesthesiology and Pain Medicine, University of Washington, Seattle, Washington; and Institute for Translational Health Sciences, University of Washington, Seattle, Washington
| | | | | | | |
Collapse
|
23
|
Thiruvenkatarajan V, Van Wijk RM, Rajbhoj A. Cranial nerve injuries with supraglottic airway devices: a systematic review of published case reports and series. Anaesthesia 2014; 70:344-59. [DOI: 10.1111/anae.12917] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/22/2014] [Indexed: 12/12/2022]
Affiliation(s)
- V. Thiruvenkatarajan
- Department of Anaesthesia; The Queen Elizabeth Hospital; Woodville South Australia Australia
- Discipline of Acute Care Medicine; The University of Adelaide; Adelaide South Australia Australia
| | - R. M. Van Wijk
- Department of Anaesthesia; The Queen Elizabeth Hospital; Woodville South Australia Australia
- Discipline of Acute Care Medicine; The University of Adelaide; Adelaide South Australia Australia
| | - A. Rajbhoj
- Department of Anaesthesia; The Queen Elizabeth Hospital; Woodville South Australia Australia
- Discipline of Acute Care Medicine; The University of Adelaide; Adelaide South Australia Australia
| |
Collapse
|
24
|
Unilateral hypoglossal nerve palsy after use of the laryngeal mask airway supreme. Case Rep Anesthesiol 2014; 2014:369563. [PMID: 25254120 PMCID: PMC4164424 DOI: 10.1155/2014/369563] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2014] [Accepted: 08/25/2014] [Indexed: 12/27/2022] Open
Abstract
Purpose. Hypoglossal nerve palsy after use of the laryngeal mask airway (LMA) is an exceptionally rare complication. We present the first case of unilateral hypoglossal nerve palsy after use of the LMA Supreme. Clinical Features. A healthy 67-year-old female was scheduled for a hallux valgus correction under general anesthesia combined with femoral and sciatic nerve blocks. A size 4 LMA Supreme was inserted successfully at the first attempt and the cuff was inflated with air at an intracuff pressure of 60 cmH2O using cuff pressure gauge. Anesthesia was maintained with oxygen, nitrous oxide (67%), and sevoflurane under spontaneous breathing. The surgery was uneventful and the duration of anesthesia was two hours. The LMA was removed as the patient woke and there were no immediate postoperative complications. The next morning, the patient complained of dysarthria and dysphasia. These symptoms were considered to be caused by the LMA compressing the nerve against the hyoid bone. Conservative treatment was chosen and the paralysis recovered completely after 5 months. Conclusion. Hypoglossal nerve injury may occur despite correct positioning of the LMA under the appropriate intracuff pressure. A follow-up period of at least 6 months should be taken into account for the recovery.
Collapse
|
25
|
Saraçoğlu A, Dal D, Pehlivan G, Göğüş FY. The Professional Experience of Anaesthesiologists in Proper Inflation of Laryngeal Mask and Endotracheal Tube Cuff. Turk J Anaesthesiol Reanim 2014; 42:234-8. [PMID: 27366428 DOI: 10.5152/tjar.2014.87487] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2013] [Accepted: 10/21/2013] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE Cuffs inflated to inappropriately high pressures cause ischemia, reducing tracheal mucosal blood flow, while cuffs inflated at lower pressure than necessary give rise to inadequate ventilation, aspiration of gastric contents, or extubation due to air leakage. In this study, we aimed to investigate the effect of the experience of anaesthesia staff on endotracheal tube and laryngeal mask airway cuff inflation. METHODS The study included 348 elective patients scheduled to undergo surgery under general anaesthesia, with 34 anaesthesia technicians, 16 anaesthesia residents, and 12 anaesthesiologists with different years of professional experience. The participants were told to inflate the cuff balloon with air to the level of the pressure that was appropriate for them. No information was provided to the participants about the values of the cuff pressure pending the completion of all measurements. After placement of the laryngeal mask airway and endotracheal tube, the success of the procedure was checked by monitoring square-wave capnograph tracing and thoracoabdominal motion. Each participant performed the procedures on three patients, and the mean cuff pressures were measured. RESULTS There was no significant correlation between duration of experience of technicians, residents, and experts in using laryngeal mask airway pressure (r=-0.192/p=0.278, r=0.225/p=0.402, r=-0.476/p=0.118, respectively) and endotracheal tube (r=-0.306/p=0.079, r=-0.060/p=0.826, r=-0.478/0.116, respectively). CONCLUSION It has been concluded that professional experience does not contribute to achieving normal cuff pressure without monitoring. Introduction of the cuff manometer into routine anaesthesia practice will be useful, irrespective of anaesthesiologists' experience.
Collapse
Affiliation(s)
- Ayten Saraçoğlu
- Department of Anaesthesiology, Marmara University Faculty of Medicine, İstanbul, Turkey
| | - Didem Dal
- Department of Anaesthesiology, Marmara University Faculty of Medicine, İstanbul, Turkey
| | - Gökhan Pehlivan
- Department of Anaesthesiology, Marmara University Faculty of Medicine, İstanbul, Turkey
| | - Fevzi Yılmaz Göğüş
- Department of Anaesthesiology, Marmara University Faculty of Medicine, İstanbul, Turkey
| |
Collapse
|
26
|
Pariente L, Camarena P, Koo M, Sabaté A, Armengol J. [Hypoglossal nerve neuropraxia after shoulder hemiarthroplasty]. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 2014; 61:277-280. [PMID: 23787368 DOI: 10.1016/j.redar.2013.04.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2013] [Revised: 04/11/2013] [Accepted: 04/17/2013] [Indexed: 06/02/2023]
Abstract
We report a case of hypoglossal nerve damage after shoulder hemiarthroplasty with the patient in "beach chair" position, performed with general anesthesia with orotracheal intubation, and without complications. An ultrasound-guided interscalene block was previously performed in an alert patient. After the intervention, the patient showed clinical symptomatology compatible with paralysis of the right hypoglossal nerve that completely disappeared after 4 weeks. Mechanisms such as hyperextension of the neck during intubation, endotracheal tube cuff pressure, excessive hyperextension, or head lateralization during surgery have been described as causes of this neurological damage. We discuss the causes, the associated factors and suggest preventive measures.
Collapse
Affiliation(s)
- L Pariente
- Servicio de Anestesiología y Reanimación, Hospital Universitario de Bellvitge, Institut d'Investigació Biomèdica de Bellvitge (IDIBELL), L'Hospitalet de Llobregat, Barcelona, España.
| | - P Camarena
- Servicio de Anestesiología y Reanimación, Hospital Universitario de Bellvitge, Institut d'Investigació Biomèdica de Bellvitge (IDIBELL), L'Hospitalet de Llobregat, Barcelona, España
| | - M Koo
- Servicio de Anestesiología y Reanimación, Hospital Universitario de Bellvitge, Institut d'Investigació Biomèdica de Bellvitge (IDIBELL), L'Hospitalet de Llobregat, Barcelona, España
| | - A Sabaté
- Servicio de Anestesiología y Reanimación, Hospital Universitario de Bellvitge, Institut d'Investigació Biomèdica de Bellvitge (IDIBELL), L'Hospitalet de Llobregat, Barcelona, España
| | - J Armengol
- Servicio de Traumatología y Ortopedia, Hospital Universitario de Bellvitge, Institut d'Investigació Biomèdica de Bellvitge (IDIBELL), L'Hospitalet de Llobregat, Barcelona, España
| |
Collapse
|
27
|
Lingual nerve injury following use of a supraglottic airway device. Br J Oral Maxillofac Surg 2014; 52:279-80. [DOI: 10.1016/j.bjoms.2013.11.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2013] [Accepted: 11/08/2013] [Indexed: 11/23/2022]
|
28
|
Thiruvenkatarajan V, Van Wijk RM, Elhalawani I, Barnes AM. Lingual nerve neuropraxia following use of the Laryngeal Mask Airway Supreme. J Clin Anesth 2014; 26:65-8. [DOI: 10.1016/j.jclinane.2013.10.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2012] [Revised: 10/24/2013] [Accepted: 10/29/2013] [Indexed: 12/19/2022]
|
29
|
Peirovifar A, Eydi M, Mirinejhad MM, Mahmoodpoor A, Mohammadi A, Golzari SE. Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation. Pak J Med Sci 2013; 29:601-5. [PMID: 24353586 PMCID: PMC3809272 DOI: 10.12669/pjms.292.2980] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2012] [Revised: 12/22/2012] [Accepted: 12/25/2012] [Indexed: 12/13/2022] Open
Abstract
OBJECTIVE To compare the postoperative complications between Laryngeal Mask Airway (LMA) and endotracheal tube (ETT) during low-flow anesthesia with controlled ventilation. METHODOLOGY Eighty adult Patients with ASA class I or II were randomly allocated into two forty-patient groups (ETT or LMA). Cuff pressure was monitored during anesthesia. After high uptake period, fresh gas flow (FGF) was decreased to 1 lit/min and isoflurane set to 1%. Monitoring during anesthesia included non-invasive blood pressure, ECG, ETCO2 and pulse oximetry. System leakage (>100 ml/min), rebreathing and any attempt to increase FGF to overcome the leak were monitored during anesthesia. Later, patients were extubated and transferred to Post Anesthesia Care Unit (PACU). In PACU, the incidence of sore throat, cough, difficulty in swallowing and shivering was monitored for all patients. RESULTS Leakage was observed in two and three cases in ETT and LMA groups respectively (P>0.05). Postoperative cough, sore throat and difficulty in swallowing were significantly less in LMA than ETT group. No significant difference was observed regarding ETCo2 values between 2 groups. CONCLUSION If careful measures regarding insertion techniques, correct LMA position and routine monitoring of LMA cuff pressure are taken, LMA can be used as a safe alternative with lower incidence of post operation complication compared with ETT during low-flow controlled anesthesia with modern anesthetic machines.
Collapse
Affiliation(s)
- Ali Peirovifar
- Ali Peirovifar, Associate Professor of Anesthesiology, Fellowship of Critical Care Medicine, Faculty of Medicine, Anesthesiology Research Team, Department of Anesthesiology, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mahmood Eydi
- Mahmood Eydi, Associate Professor of Anesthesiology, Faculty of Medicine, Anesthesiology Research Team, Department of Anesthesiology, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mir Mousa Mirinejhad
- Mir Mousa Mirinejhad, Associate Professor of Anesthesiology, Fellowship of cardiovascular anesthesia, Faculty of Medicine, Anesthesiology Research Team, Department of Anesthesiology, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Ata Mahmoodpoor
- Ata Mahmoodpoor, Assistant Professor of Anesthesiology, Fellowship of Critical Care Medicine, Faculty of Medicine, Anesthesiology Research Team, Department of Anesthesiology, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Afsaneh Mohammadi
- Afsaneh Mohammadi, Medicine student, Faculty of Medicine, Anesthesiology Research Team, Department of Anesthesiology, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Samad Ej Golzari
- Samad EJ Golzari, Physical Medicine and Rehabilitation Research Center, Students' Research Committee, Anesthesiology Research Team, Department of Anesthesiology, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
30
|
Sharma B, Gupta R, Sehgal R, Koul A, Sood J. ProSeal™ laryngeal mask airway cuff pressure changes with and without use of nitrous oxide during laparoscopic surgery. J Anaesthesiol Clin Pharmacol 2013; 29:47-51. [PMID: 23493234 PMCID: PMC3590541 DOI: 10.4103/0970-9185.105795] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Background: The ProSeal™ laryngeal mask (PLMA) is increasingly being used as an airway device for laparoscopic surgery. Its silicone cuff allows diffusion of nitrous oxide, carbon dioxide and other gases with resultant rise in its intracuff pressure during anesthesia. The present study was designed to investigate the intracuff pressure changes during anesthesia with and without nitrous oxide in patients undergoing laparoscopic surgery lasting up to two hours. Materials and Methods: One hundred patients, American Society of Anesthesiologists physical status 2 and 3, undergoing general anesthesia with muscle paralysis, were randomized into two groups of 50 patients each to receive an anesthetic gas mixture containing either oxygen and nitrous oxide (group N) or oxygen and air (group A). Following insertion of an appropriate size PLMA, its cuff was inflated with air to an intracuff pressure of 45 mm Hg. The cuff pressure was measured every 10 minutes for the entire course of anesthesia. The position of the device was also assessed fiberoptically and postoperative airway complications were recorded. Results: The maximum intracuff pressure recorded in group N was 103 ± 4.7 mm Hg vs. 45.5 ± 1.5 mm Hg in group A. The percentage rise in cuff pressure every 10 minutes was also highly significant (P < 0.001) being maximum in first 10 min in group N. The incidence of postoperative airway complications was comparable between the two groups. Conclusion: The results of this study demonstrate that the intracuff pressure of the PLMA increases progressively over time when the breathing gas mixture contains nitrous oxide.
Collapse
Affiliation(s)
- Bimla Sharma
- Department of Anaesthesiology, Pain and Perioperative Medicine, Sir Ganga Ram Hospital, Old Rajinder Nagar, New Delhi, India
| | | | | | | | | |
Collapse
|
31
|
Cook T, MacDougall-Davis S. Complications and failure of airway management. Br J Anaesth 2012; 109 Suppl 1:i68-i85. [DOI: 10.1093/bja/aes393] [Citation(s) in RCA: 269] [Impact Index Per Article: 22.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
|
32
|
RUJIROJINDAKUL P, PRECHAWAI C, WATANAYOMNAPORN E. Tongue numbness following laryngeal mask airway Supreme™ and i-gel™ insertion: two case reports. Acta Anaesthesiol Scand 2012; 56:1200-3. [PMID: 22524512 DOI: 10.1111/j.1399-6576.2012.02695.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/24/2012] [Indexed: 12/26/2022]
Abstract
We present two cases of transient lingual nerve injury that were associated with the use of a laryngeal mask airway Supreme™ (The Laryngeal Mask Company, Singapore) during lumbar discectomy in a 43-year-old female and i-gel™ (Intersurgical, Berkshire, UK) during ovum pick up in a 33-year-old female. They presented with numbness at the tip of their tongues and spontaneously and fully recovered 2 weeks after their operations.
Collapse
Affiliation(s)
- P. RUJIROJINDAKUL
- Department of Anaesthesiology; Faculty of Medicine, Prince of Songkla University; Songkhla; Thailand
| | - C. PRECHAWAI
- Department of Anaesthesiology; Faculty of Medicine, Prince of Songkla University; Songkhla; Thailand
| | - E. WATANAYOMNAPORN
- Department of Anaesthesiology; Faculty of Medicine, Prince of Songkla University; Songkhla; Thailand
| |
Collapse
|
33
|
|
34
|
Teoh PF, Seet E, Macachor J, Chia N. Accuracy of ProSeal™ Laryngeal Mask Airway Intracuff Pressure Estimation using Finger Palpation technique – A Prospective, Observational Study. Anaesth Intensive Care 2012; 40:467-71. [DOI: 10.1177/0310057x1204000312] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The incidence of pharyngolaryngeal adverse events associated with laryngeal mask airways can be reduced by the use of manometry to limit the laryngeal mask airway intracuff pressures. We conducted a prospective, observational study in 80 patients undergoing general anaesthesia with the ProSeal™ laryngeal mask airway to determine the accuracy of a finger palpation technique compared to actual readings obtained from a handheld manometer by different anaesthesia personnel. The strength of association of estimated versus actual intracuff pressures, R, for nurse anaesthesia assistants, junior anaesthetists and senior anaesthetists were 0.21 (weak), 0.35 (moderate) and 0.78 (strong) respectively. Subgroup analysis showed that anaesthetists with more than three years of experience were more accurate than those with less than three years of experience. The actual versus estimated intracuff pressures were 4±17 vs 19±27 cmH2O ( P value <0.001) respectively. In all groups, the palpation technique tended to underestimate the actual intracuff pressure by a mean of 10.3 cmH2O. Palpation accuracy decreased when actual intracuff pressures were >80 cmH2O. These findings suggest that cuff pressure manometry should be recommended as standard of care with the use of laryngeal mask airways.
Collapse
Affiliation(s)
- P. F. Teoh
- Department of Anaesthesia and Surgical Intensive Care, Khoo Teck Puat Hospital, Republic of Singapore
| | - E. Seet
- Department of Anaesthesia and Surgical Intensive Care, Khoo Teck Puat Hospital, Republic of Singapore
| | - J. Macachor
- Department of Anaesthesia and Surgical Intensive Care, Khoo Teck Puat Hospital, Republic of Singapore
| | - N. Chia
- Department of Anaesthesia and Surgical Intensive Care, Khoo Teck Puat Hospital, Republic of Singapore
| |
Collapse
|
35
|
Lingual Nerve Paralysis After Endobronchial Ultrasound Utilizing Laryngeal Mask Airway. J Bronchology Interv Pulmonol 2012. [DOI: 10.1097/lbr.0b013e318241414a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
36
|
Abdellatif AA, Ali MA. Comparison of streamlined liner of the pharynx airway (SLIPA™) with the laryngeal mask airway Proseal™ for lower abdominal laparoscopic surgeries in paralyzed, anesthetized patients. Saudi J Anaesth 2011; 5:270-6. [PMID: 21957405 PMCID: PMC3168343 DOI: 10.4103/1658-354x.84100] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Context: Supraglottic airway devices have been used as an alternative to tracheal intubation during laparoscopic surgery. Aims: The study was designed to compare the efficacy of Streamlined Liner of the Pharynx Airway (SLIPA) for positive pressure ventilation and postoperative complications with the Laryngeal Mask Airway ProSeal (PLMA) for patients undergoing lower abdominal laparoscopies under general anesthesia with controlled ventilation. Settings and Design: Prospective, crossover randomized controlled trial performed on patients undergoing lower abdominal laparoscopic surgeries. Methods: A total of 120 patients undergoing lower abdominal laparoscopic surgeries were randomly allocated into two equal groups; PLMA and SLIPA groups. Number of intubation attempts, insertion time, ease of insertion, and fiberoptic bronchoscopic view were recorded. Lung mechanics data were collected 5 minutes after securing the airway, then after abdominal insufflation. Blood traces and regurgitation were checked for; postoperative sore throat and other complications were recorded. Statistical Analysis: Arithmetic mean and standard deviation values were calculated and statistical analyses were performed for each group. Independent sample t-test was used to compare continuous variables exhibiting normal distribution, and Chi-squared test for noncontinuous variables. P value <0.05 was considered significant. Results: Insertion time, first insertion success rate, and ease of insertion were comparable in both groups. Fiberoptic bronchoscopic view was significantly better and epiglottic downfolding was significantly lower in SLIPA group. Sealing pressure and lung mechanics were similar. Gastric distension was not observed in both groups. Postoperative sore throat was significantly higher in PACU in PLMA group. Blood traces on the device were significantly more in SLIPA group. Conclusions: SLIPA can be used as a useful alternative to PLMA in patients undergoing lower abdominal laparoscopic surgery with muscle relaxant and controlled ventilation.
Collapse
|
37
|
Chen WH, Yin HL, Lui CC, Lin HS. Isolated numbness of the tip of the tongue in hemispheric stroke. ACTA ACUST UNITED AC 2011; 111:e11-4. [PMID: 21497526 DOI: 10.1016/j.tripleo.2011.01.043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2010] [Revised: 01/26/2011] [Accepted: 01/29/2011] [Indexed: 10/18/2022]
Abstract
Although the somatosensory afferent of the tip of the tongue runs proximal and parallel along the spinothalamocortical and trigeminothalamocortical pathway up to the sensory cortex, central involvement has been rarely described in cases of nongustatory sensory disturbance at the tip of the tongue. In a hypertensive woman who experienced an acute onset of an isolated numbness at the tip of her tongue, recent small infarctions were found at the postcentral gyrus of the right parietal lobe. Thus, central involvement should not be neglected in the case of sensory disturbance at the tip of tongue.
Collapse
Affiliation(s)
- Wei-Hsi Chen
- Department of Neurology, Chang Gung Memorial Hospital-Kaohsiung Medical Center and College of Medicine, Chang Gung University, Kaohsiung, Taiwan
| | | | | | | |
Collapse
|
38
|
Hanumanthaiah D, Masud S, Ranganath A. Inferior alveolar nerve injury with laryngeal mask airway: a case report. J Med Case Rep 2011; 5:122. [PMID: 21447166 PMCID: PMC3073919 DOI: 10.1186/1752-1947-5-122] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2010] [Accepted: 03/29/2011] [Indexed: 11/24/2022] Open
Abstract
INTRODUCTION The incidence of damage to the individual cranial nerves and their branches associated with laryngeal mask airway use is low; there have been case reports of damage to the lingual nerve, hypoglossal nerve and recurrent laryngeal nerve. To the best of our knowledge we present the first reported case of inferior alveolar nerve injury associated with laryngeal mask airway use. CASE PRESENTATION A 35-year-old Caucasian man presented to our facility for elective anterior cruciate ligament repair. He had no background history of any significant medical problems. He opted for general anesthesia over a regional technique. He was induced with fentanyl and propofol and a size 4 laryngeal mask airway was inserted without any problems. His head was in a neutral position during the surgery. After surgery in the recovery room, he complained of numbness in his lower lip. He also developed extensive scabbing of the lower lip on the second day after surgery. The numbness and scabbing started improving after a week, with complete recovery after two weeks. CONCLUSION We report the first case of vascular occlusion and injury to the inferior alveolar nerve, causing scabbing and numbness of the lower lip, resulting from laryngeal mask airway use. This is an original case report mostly of interest for anesthetists who use the laryngeal mask airway in day-to-day practice. Excessive inflation of the laryngeal mask airway cuff could have led to this complication. Despite the low incidence of cranial nerve injury associated with the use of the laryngeal mask airway, vigilant adherence to evidence-based medicine techniques and recommendations from the manufacturer's instructions can prevent such complications.
Collapse
Affiliation(s)
| | - Sarmad Masud
- Department of Anaesthesia, Our Lady of Lourdes Hospital, Drogheda, Ireland
| | - Anil Ranganath
- Department of Anaesthesia, Cork University Hospital, Cork, Ireland
| |
Collapse
|
39
|
Renes SH, Zwart R, Scheffer GJ, Renes S. Lingual nerve injury following the use of an i-gel laryngeal mask. Anaesthesia 2011; 66:226-7. [DOI: 10.1111/j.1365-2044.2011.06636.x] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
40
|
Rokamp KZ, Secher NH, Møller AM, Nielsen HB. Tracheal tube and laryngeal mask cuff pressure during anaesthesia - mandatory monitoring is in need. BMC Anesthesiol 2010; 10:20. [PMID: 21129183 PMCID: PMC3016349 DOI: 10.1186/1471-2253-10-20] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2010] [Accepted: 12/03/2010] [Indexed: 02/20/2023] Open
Abstract
Background To prevent endothelium and nerve lesions, tracheal tube and laryngeal mask cuff pressure is to be maintained at a low level and yet be high enough to secure air sealing. Method In a prospective quality-control study, 201 patients undergoing surgery during anaesthesia (without the use of nitrous oxide) were included for determination of the cuff pressure of the tracheal tubes and laryngeal masks. Results In the 119 patients provided with a tracheal tube, the median cuff pressure was 30 (range 8 - 100) cm H2O and the pressure exceeded 30 cm H2O (upper recommended level) for 54 patients. In the 82 patients provided with a laryngeal mask, the cuff pressure was 95 (10 - 121) cm H2O and above 60 cm H2O (upper recommended level) for 56 patients and in 34 of these patients, the pressure exceeded the upper cuff gauge limit (120 cm H2O). There was no association between cuff pressure and age, body mass index, type of surgery, or time from induction of anaesthesia to the time the cuff pressure was measured. Conclusion For maintenance of epithelia flow and nerve function and at the same time secure air sealing, this evaluation indicates that the cuff pressure needs to be checked as part of the procedures involved in induction of anaesthesia and eventually checked during surgery.
Collapse
Affiliation(s)
- Kim Z Rokamp
- Department of Anaesthesia, University of Copenhagen, Herlev Hospital, Herlev Ringvej 7, DK-2730 Herlev, Denmark.
| | | | | | | |
Collapse
|
41
|
Woo YC, Cha SM, Kang H, Baek CW, Jung YH, Kim JY, Koo GH, Park SG, Kim SD. Less perilaryngeal gas leakage with SLIPATM than with LMA-ProSealTM in paralyzed patients. Can J Anaesth 2010; 58:48-54. [DOI: 10.1007/s12630-010-9412-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2010] [Accepted: 10/18/2010] [Indexed: 11/30/2022] Open
|
42
|
Application of the Laryngeal Mask Airway for Anesthesia in Three Chimpanzees and One Gibbon. J Zoo Wildl Med 2010; 41:535-7. [DOI: 10.1638/2009-0120.1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
43
|
Choi YM, Cha SM, Kang H, Baek CW, Jung YH, Woo YC, Kim JY, Koo GH, Park SG. The clinical effectiveness of the streamlined liner of pharyngeal airway (SLIPA) compared with the laryngeal mask airway ProSeal during general anesthesia. Korean J Anesthesiol 2010; 58:450-7. [PMID: 20532053 PMCID: PMC2881520 DOI: 10.4097/kjae.2010.58.5.450] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2010] [Revised: 03/03/2010] [Accepted: 03/12/2010] [Indexed: 11/23/2022] Open
Abstract
Background The aim of this study was to compare the streamlined liner of the pharynx airway (SLIPA), a new supraglottic airway device (SGA), with the laryngeal mask airway ProSeal™ (PLMA) during general anesthesia. Methods Sixty patients were randomly allocated to two groups; a PLMA group (n = 30) or a SLIPA group (n = 30). Ease of use, first insertion success rate, hemodynamic responses to insertion, ventilatory efficiency and positioning confirmed by fiberoptic bronchoscopy were assessed. Lung mechanics data were collected with side stream spirometry at 10 minutes after insertion. We also compared the incidence of blood stain, incidence and severity of postoperative sore throat and other complications. Results First attempt success rates were 93.3% and 73.3%, and mean insertion time was 7.3 sec and 10.5 sec in PLMA and SLIPA. There was a significant rise in all of hemodynamic response from the pre-insertion value at one minute following insertion of SLIPA. But, insertion of PLMA was no significant rise in hemodynamic response. There was no statistically significant difference in the mean maximum sealing pressure, gas leakage, lung mechanics data, gastric distension, postoperative sore throat and other complication between the two groups. Blood stain were noted on the surface of the device in 40% (n = 12) in the SLIPA vs. 6.7% (n = 2) in the PLMA. Conclusions The SLIPA is a useful alternative to the PLMA and have comparable efficacy and complication rates. If we acquire the skill to use, SLIPA may be considered as primary SGA devices during surgery under general anesthesia.
Collapse
Affiliation(s)
- Yun Mi Choi
- Department of Anesthesiology and Pain Medicine, College of Medicine, Chung-Ang University, Seoul, Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Tan BH, Chen FG, Liu EHC. An Evaluation of the Laryngeal Mask Airway Supreme™ in 100 Patients. Anaesth Intensive Care 2010; 38:550-4. [DOI: 10.1177/0310057x1003800322] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The Laryngeal Mask Airway (LMA) Supreme™ is a new supraglottic airway incorporating features of the LMA Proseal™, LMA Fastrach™ and LMA Unique™. We evaluated the LMA Supreme in 100 patients with normal airways having elective surgery. Our success rates of insertion and ventilation were 96% at the first attempt and 100% after two attempts. The median time to successful placement was 15 seconds (interquartile range 12 to 18 seconds). Forty-five patients breathed spontaneously and 55 patients had controlled ventilation. The incidence of blood staining on removal was 7% and 7% of patients had mild sore throat one hour postoperatively. One patient who had been placed in the left lateral position during surgery had left lingual nerve palsy postoperatively, which recovered completely after one month. Our findings suggest that in patients with normal airways, the LMA Supreme is easy to insert and provides a satisfactory airway with adequate seal pressures for ventilation.
Collapse
Affiliation(s)
- B. H. Tan
- Department of Anaesthesia, National University Health System, Singapore
- (Anaesthesia), Anaesthesia Associate Consultant
| | - F. G. Chen
- Department of Anaesthesia, National University Health System, Singapore
- Senior Consultant and Head of Department
| | - E. H. C. Liu
- Department of Anaesthesia, National University Health System, Singapore
| |
Collapse
|
45
|
Bakker EJ, Valkenburg M, Galvin EM. Pilot study of the air-Q intubating laryngeal airway in clinical use. Anaesth Intensive Care 2010; 38:346-8. [PMID: 20369770 DOI: 10.1177/0310057x1003800217] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The air-Q Intubating Laryngeal Airway (ILA) is a newly introduced extraglottic airway device. In this pilot study, we evaluated its use as a routine airway device during positive pressure ventilation. Ease of endotracheal intubation through the device was also assessed. Fifty-nine ASA I and II patients undergoing elective surgery received an air-Q ILA and an endotracheal tube where indicated. Insertion, ventilation and intubation characteristics were noted, as well as throat morbidity and occurrence of adverse events. An air-Q ILA was successfully inserted in 100% of patients. Mean leak pressure was 19 +/- 5 cmH2O. Endotracheal intubation was indicated in 19 patients and successful in 58% on the first attempt and 74% in total. Ten percent of the study patients were noted to have dysphagia. One patient was diagnosed with bilateral lingual nerve injury but made a complete recovery in four weeks. The air-Q ILA is an adequate extraglottic airway device in terms of insertion and ventilation. However the proposed advantage of ease of endotracheal intubation requires further investigation.
Collapse
Affiliation(s)
- E J Bakker
- Department ofAnesthesiology, Erasmus University Medical Center, Rotterdam, The Netherlands
| | | | | |
Collapse
|
46
|
Course and distribution of the lingual nerve in the ventral tongue region: anatomical considerations for frenectomy. J Craniofac Surg 2010; 20:1359-63. [PMID: 19816256 DOI: 10.1097/scs.0b013e3181ae42fa] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
The aim of this study was to elucidate the sublingual and intralingual courses of the lingual nerve (LN) in the ventral tongue region, providing a clinical guide for safe surgical procedures such as frenectomy. We evaluated 16 specimens (32 sides) by gross observation after detailed dissections, and a further 6 specimens were examined after Sihler staining. All specimens were harvested from embalmed Korean cadavers. We classified the innervation patterns of the LN into 5 types and confirmed the distribution of the LN in the tip of the tongue. The classification of the LN was made with reference to a line formed by the interlacing of the styloglossus and genioglossus muscles. Based on the course of LN and the presence of a tiny twig (twigs directly innervating the ventral mucosa of the tongue, TM) directly innervating the sublingual mucosa, the course of the LN was classified as being straight, curved, or vertical and with or without the TM. Straight, curved, and vertical courses without the TM were seen in 9.4%, 46.9%, and 18.8% of the cases, respectively. Straight and curved courses with the TM were observed in 6.3% and 18.8% of the cases, respectively. Sihler staining revealed that the tongue tip is innervated by the LN. These findings indicate that surgical manipulations at the ventral tongue region might damage the LN and result in numbness of the tongue tip, and provide a useful anatomic reference for various surgical procedures involving the ventral tongue region.
Collapse
|
47
|
|
48
|
Foley E, Mc Dermott TED, Shanahan E, Phelan D. Transient isolated lingual nerve neuropraxia associated with general anaesthesia and laryngeal mask use: two case reports and a review of the literature. Ir J Med Sci 2009; 179:297-300. [PMID: 19437092 DOI: 10.1007/s11845-009-0347-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2008] [Accepted: 04/16/2009] [Indexed: 12/01/2022]
Abstract
BACKGROUND Transient, isolated lingual nerve neuropraxia is a rare complication following general anaesthesia. Reports implicate airway manipulation and we describe two new cases associated with laryngeal mask airway (LMA) and review the related English language literature. RESULTS Unilateral numbness and loss of taste on the anterior tongue were the characteristic symptoms. Collation of literature data (median and range) with that from the new cases showed: patient age was 38 (20-61) years and female to male ratio was 1.2:1. Surgery time was 62.5 (20-150) min and symptom duration was 28 (7-120) days. CONCLUSION Lingual neuropraxias reported have been transient and patients can be advised, despite disturbing symptoms, that recovery is anticipated in about 1 month. Lingual neuropraxia reports are becoming more frequent, perhaps associated with increasing LMA use. Research is recommended as modification to LMA cuff volume, pressure and/or position within the oral cavity might ameliorate the entity.
Collapse
Affiliation(s)
- E Foley
- Department of Anaesthesia and Intensive Care, Mater Hospital, Dublin, Ireland.
| | | | | | | |
Collapse
|
49
|
Jeon IS, Kim SB, Lee DG, Park JG, Bae SC. Bilateral symmetric lacerations of the soft palate after general anesthesia using the laryngeal mask airway ProSeal(TM): A case report. Korean J Anesthesiol 2009; 56:438-442. [PMID: 30625767 DOI: 10.4097/kjae.2009.56.4.438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
ProSeal(TM) laryngeal mask airway (PLMA) was developed to be more effective especially with glottic airway sealing and is suppose to be an improved device over the classic laryngeal mask airway (cLMA). The PLMA's cuff is bulkier, softer, and more pliable than the cLMA. We reviewed a case were a patient had hand surgery under general anesthesia using the PLMA. After having the hand surgery, the patient suffered from dyspnea and had difficulty with their respirations at a supine position. The problems with dyspnea and respiration after surgery resulted because of difficulties from inserting PLMA No.5 into the patient. We suspect from this case that the problems in dyspnea and respiration were due to the folded cuff and incomplete placement of the PLMA, which resulted in lacerations of the mucosa in the soft palate of the patient. In this paper, we considered the probable causes for lacerations of the mucosa in the soft palate and reviewed all of the relevant literature, especially about the proper placement of the PLMA.
Collapse
Affiliation(s)
- In Suk Jeon
- Department of Anesthesiology and Pain Medicine, College of Medicine, Soonchunhyang University, Gumi, Korea.
| | - Sang Baek Kim
- Department of Anesthesiology and Pain Medicine, College of Medicine, Soonchunhyang University, Gumi, Korea.
| | - Dong Gi Lee
- Department of Anesthesiology and Pain Medicine, College of Medicine, Soonchunhyang University, Gumi, Korea.
| | - Jin Gue Park
- Department of Anesthesiology and Pain Medicine, College of Medicine, Soonchunhyang University, Gumi, Korea.
| | - Sang Cheul Bae
- Department of Anesthesiology and Pain Medicine, College of Medicine, Soonchunhyang University, Gumi, Korea.
| |
Collapse
|
50
|
Mun CS, Kim HT, Heo HE, Lee JH, Kwon YE. Unilateral vocal cord palsy occurred after difficult endotracheal intubation using intubating laryngeal mask airway: A case report. Korean J Anesthesiol 2009; 56:200-203. [PMID: 30625722 DOI: 10.4097/kjae.2009.56.2.200] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Airway management is important during general anesthesia. Difficulties with a direct laryngoscopy can be managed successfully in a routine manner using a laryngeal mask airway. A 65-year-old woman was scheduled to undergo gynecologic surgery. After injecting the intravenous induction agents and muscle relaxants, intubation was attempted with a direct laryngoscope. However, the vocal cords could not be observed with only the epiglottis being slightly visible. Although intubation was re-attempted by another anesthesiologist, it failed. Intubation was successfully performed via an intubating laryngeal mask airway (ILMA) after additional 100% oxygen mask ventilation. We report a case of vocal cord palsy subsequent to tracheal extubation after endotracheal intubation via ILMA.
Collapse
Affiliation(s)
- Cheol Sin Mun
- Department of Anesthesiology and Pain Medicine, Presbyterian Medical Center, Jeonju, Korea.
| | - Hyung Tae Kim
- Department of Anesthesiology and Pain Medicine, Presbyterian Medical Center, Jeonju, Korea.
| | - Hyeon Eon Heo
- Department of Anesthesiology and Pain Medicine, Presbyterian Medical Center, Jeonju, Korea.
| | - Jun Hak Lee
- Department of Anesthesiology and Pain Medicine, Presbyterian Medical Center, Jeonju, Korea.
| | - Young Eun Kwon
- Department of Anesthesiology and Pain Medicine, Presbyterian Medical Center, Jeonju, Korea.
| |
Collapse
|