Cabezudo Ballesteros S, Sanabria Carretero P, Reinoso Barbero F. Review of electrical impedance tomography in the pediatric patient. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 2024; 71:479-485. [PMID: 38458492 DOI: 10.1016/j.redare.2024.03.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 08/28/2023] [Indexed: 03/10/2024]
Abstract
Electrical impedance tomography (EIT) is a new method of monitoring non-invasive mechanical ventilation, at the bedside and useful in critically ill patients. It allows lung monitoring of ventilation and perfusion, obtaining images that provide information on lung function. It is based on the physical principle of impedanciometry or the body's ability to conduct an electrical current. Various studies have shown its usefulness both in adults and in pediatrics in respiratory distress syndrome, pneumonia and atelectasis in addition to pulmonary thromboembolism and pulmonary hypertension by also providing information on pulmonary perfusion, and may be very useful in perioperative medicine; especially in pediatrics avoiding repetitive imaging tests with ionizing radiation.
Collapse
Affiliation(s)
| | - P Sanabria Carretero
- Servicio de Anestesia y Reanimación, Hospital Universitario La Paz, Madrid, Spain
| | - F Reinoso Barbero
- Servicio de Anestesia y Reanimación, Hospital Universitario La Paz, Madrid, Spain
| |
Collapse
|
2
|
Franchineau G, Jonkman AH, Piquilloud L, Yoshida T, Costa E, Rozé H, Camporota L, Piraino T, Spinelli E, Combes A, Alcala GC, Amato M, Mauri T, Frerichs I, Brochard LJ, Schmidt M. Electrical Impedance Tomography to Monitor Hypoxemic Respiratory Failure. Am J Respir Crit Care Med 2024; 209:670-682. [PMID: 38127779 DOI: 10.1164/rccm.202306-1118ci] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 12/20/2023] [Indexed: 12/23/2023] Open
Abstract
Hypoxemic respiratory failure is one of the leading causes of mortality in intensive care. Frequent assessment of individual physiological characteristics and delivery of personalized mechanical ventilation (MV) settings is a constant challenge for clinicians caring for these patients. Electrical impedance tomography (EIT) is a radiation-free bedside monitoring device that is able to assess regional lung ventilation and changes in aeration. With real-time tomographic functional images of the lungs obtained through a thoracic belt, clinicians can visualize and estimate the distribution of ventilation at different ventilation settings or following procedures such as prone positioning. Several studies have evaluated the performance of EIT to monitor the effects of different MV settings in patients with acute respiratory distress syndrome, allowing more personalized MV. For instance, EIT could help clinicians find the positive end-expiratory pressure that represents a compromise between recruitment and overdistension and assess the effect of prone positioning on ventilation distribution. The clinical impact of the personalization of MV remains to be explored. Despite inherent limitations such as limited spatial resolution, EIT also offers a unique noninvasive bedside assessment of regional ventilation changes in the ICU. This technology offers the possibility of a continuous, operator-free diagnosis and real-time detection of common problems during MV. This review provides an overview of the functioning of EIT, its main indices, and its performance in monitoring patients with acute respiratory failure. Future perspectives for use in intensive care are also addressed.
Collapse
Affiliation(s)
- Guillaume Franchineau
- Service de Medecine Intensive Reanimation, Centre Hospitalier Intercommunal de Poissy-Saint-Germain-en-Laye, Poissy, France
| | - Annemijn H Jonkman
- Department of Intensive Care Medicine, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Lise Piquilloud
- Adult Intensive Care Unit, Lausanne University Hospital and Lausanne University, Lausanne, Switzerland
| | - Takeshi Yoshida
- Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Eduardo Costa
- Pulmonary Division, Cardiopulmonary Department, Heart Institute, University of São Paulo, São Paulo, Brazil
| | - Hadrien Rozé
- Department of Thoraco-Abdominal Anesthesiology and Intensive Care, Bordeaux University Hospital, University of Bordeaux, Bordeaux, France
- Réanimation Polyvalente, Centre Hospitalier Côte Basque, Bayonne, France
| | - Luigi Camporota
- Health Centre for Human and Applied Physiological Sciences, Department of Adult Critical Care, Guy's and St Thomas' National Health Service Foundation Trust, London, United Kingdom
| | - Thomas Piraino
- Keenan Research Centre for Biomedical Science, Li Ka Shing Knowledge Institute, Unity Health Toronto, Toronto, Ontario, Canada
- Division of Critical Care, Department of Anesthesia, McMaster University, Hamilton, Ontario, Canada
| | - Elena Spinelli
- Department of Anesthesia, Critical Care and Emergency, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Alain Combes
- Sorbonne Université, Groupe de Recherche Clinique 30, Réanimation et Soins Intensifs du Patient en Insuffisance Respiratoire Aigüe, UMRS_1166-ICAN, Institute of Cardiometabolism and Nutrition, Service de Médecine Intensive - Réanimation, Assistance Publique-Hôpitaux de Paris (APHP) Hôpital Pitié-Salpêtrière, Paris, France
| | - Glasiele C Alcala
- Pulmonary Division, Cardiopulmonary Department, Heart Institute, University of São Paulo, São Paulo, Brazil
| | - Marcelo Amato
- Pulmonary Division, Cardiopulmonary Department, Heart Institute, University of São Paulo, São Paulo, Brazil
| | - Tommaso Mauri
- Department of Anesthesia, Critical Care and Emergency, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
- Department of Pathophysiology and Transplants, University of Milan, Milan, Italy
| | - Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Centre of Schleswig-Holstein Campus Kiel, Kiel, Germany; and
| | - Laurent J Brochard
- Keenan Research Centre for Biomedical Science, Li Ka Shing Knowledge Institute, Unity Health Toronto, Toronto, Ontario, Canada
- Interdepartmental Division of Critical Care, University of Toronto, Toronto, Ontario, Canada
| | - Matthieu Schmidt
- Sorbonne Université, Groupe de Recherche Clinique 30, Réanimation et Soins Intensifs du Patient en Insuffisance Respiratoire Aigüe, UMRS_1166-ICAN, Institute of Cardiometabolism and Nutrition, Service de Médecine Intensive - Réanimation, Assistance Publique-Hôpitaux de Paris (APHP) Hôpital Pitié-Salpêtrière, Paris, France
| |
Collapse
|
3
|
Heines SJH, Becher TH, van der Horst ICC, Bergmans DCJJ. Clinical Applicability of Electrical Impedance Tomography in Patient-Tailored Ventilation: A Narrative Review. Tomography 2023; 9:1903-1932. [PMID: 37888742 PMCID: PMC10611090 DOI: 10.3390/tomography9050150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 10/05/2023] [Accepted: 10/16/2023] [Indexed: 10/28/2023] Open
Abstract
Electrical Impedance Tomography (EIT) is a non-invasive bedside imaging technique that provides real-time lung ventilation information on critically ill patients. EIT can potentially become a valuable tool for optimising mechanical ventilation, especially in patients with acute respiratory distress syndrome (ARDS). In addition, EIT has been shown to improve the understanding of ventilation distribution and lung aeration, which can help tailor ventilatory strategies according to patient needs. Evidence from critically ill patients shows that EIT can reduce the duration of mechanical ventilation and prevent lung injury due to overdistension or collapse. EIT can also identify the presence of lung collapse or recruitment during a recruitment manoeuvre, which may guide further therapy. Despite its potential benefits, EIT has not yet been widely used in clinical practice. This may, in part, be due to the challenges associated with its implementation, including the need for specialised equipment and trained personnel and further validation of its usefulness in clinical settings. Nevertheless, ongoing research focuses on improving mechanical ventilation and clinical outcomes in critically ill patients.
Collapse
Affiliation(s)
- Serge J. H. Heines
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
| | - Tobias H. Becher
- Department of Anesthesiology and Intensive Care Medicine, Campus Kiel, University Medical Centre Schleswig-Holstein, 24118 Kiel, Germany;
| | - Iwan C. C. van der Horst
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, 6229 HX Maastricht, The Netherlands
| | - Dennis C. J. J. Bergmans
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
- School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, 6229 ER Maastricht, The Netherlands
| |
Collapse
|
4
|
Jiang H, Han Y, Zheng X, Fang Q. Roles of electrical impedance tomography in lung transplantation. Front Physiol 2022; 13:986422. [PMID: 36407002 PMCID: PMC9669435 DOI: 10.3389/fphys.2022.986422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 10/25/2022] [Indexed: 11/06/2022] Open
Abstract
Lung transplantation is the preferred treatment method for patients with end-stage pulmonary disease. However, several factors hinder the progress of lung transplantation, including donor shortages, candidate selection, and various postoperative complications. Electrical impedance tomography (EIT) is a functional imaging tool that can be used to evaluate pulmonary ventilation and perfusion at the bedside. Among patients after lung transplantation, monitoring the graft’s pulmonary function is one of the most concerning issues. The feasible application of EIT in lung transplantation has been reported over the past few years, and this technique has gained increasing interest from multidisciplinary researchers. Nevertheless, physicians still lack knowledge concerning the potential applications of EIT in lung transplantation. We present an updated review of EIT in lung transplantation donors and recipients over the past few years, and discuss the potential use of ventilation- and perfusion-monitoring-based EIT in lung transplantation.
Collapse
Affiliation(s)
| | | | - Xia Zheng
- *Correspondence: Xia Zheng, ; Qiang Fang,
| | - Qiang Fang
- *Correspondence: Xia Zheng, ; Qiang Fang,
| |
Collapse
|
5
|
The anatomical landmarks for positioning of double lumen endotracheal tube using flexible bronchoscopy: A prospective observational study. Heliyon 2022; 8:e11779. [DOI: 10.1016/j.heliyon.2022.e11779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 09/14/2022] [Accepted: 11/14/2022] [Indexed: 11/22/2022] Open
|
6
|
Rauseo M, Spinelli E, Sella N, Slobod D, Spadaro S, Longhini F, Giarratano A, Gilda C, Mauri T, Navalesi P. Expert opinion document: "Electrical impedance tomography: applications from the intensive care unit and beyond". JOURNAL OF ANESTHESIA, ANALGESIA AND CRITICAL CARE (ONLINE) 2022; 2:28. [PMID: 37386674 DOI: 10.1186/s44158-022-00055-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Accepted: 06/01/2022] [Indexed: 07/01/2023]
Abstract
Mechanical ventilation is a life-saving technology, but it can also inadvertently induce lung injury and increase morbidity and mortality. Currently, there is no easy method of assessing the impact that ventilator settings have on the degree of lung inssflation. Computed tomography (CT), the gold standard for visually monitoring lung function, can provide detailed regional information of the lung. Unfortunately, it necessitates moving critically ill patients to a special diagnostic room and involves exposure to radiation. A technique introduced in the 1980s, electrical impedance tomography (EIT) can non-invasively provide similar monitoring of lung function. However, while CT provides information on the air content, EIT monitors ventilation-related changes of lung volume and changes of end expiratory lung volume (EELV). Over the past several decades, EIT has moved from the research lab to commercially available devices that are used at the bedside. Being complementary to well-established radiological techniques and conventional pulmonary monitoring, EIT can be used to continuously visualize the lung function at the bedside and to instantly assess the effects of therapeutic maneuvers on regional ventilation distribution. EIT provides a means of visualizing the regional distribution of ventilation and changes of lung volume. This ability is particularly useful when therapy changes are intended to achieve a more homogenous gas distribution in mechanically ventilated patients. Besides the unique information provided by EIT, its convenience and safety contribute to the increasing perception expressed by various authors that EIT has the potential to be used as a valuable tool for optimizing PEEP and other ventilator settings, either in the operative room and in the intensive care unit. The effects of various therapeutic interventions and applications on ventilation distribution have already been assessed with the help of EIT, and this document gives an overview of the literature that has been published in this context.
Collapse
Affiliation(s)
- Michela Rauseo
- Department of Anesthesia and Intensive Care Medicine, University of Foggia, Policlinico Riuniti di Foggia, Foggia, Italy.
| | - Elena Spinelli
- Department of Anesthesia, Critical Care and Emergency, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Ca' Granda Ospedale Maggiore Policlinico Milan, Milano, Italy
| | - Nicolò Sella
- Instiute of Anesthesia and Intensive Care, Padua University Hospital, Padova, Italy
| | - Douglas Slobod
- Department of Anesthesia, Critical Care and Emergency, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Ca' Granda Ospedale Maggiore Policlinico Milan, Milano, Italy
- Department of Critical Care Medicine, McGill University, Montreal, Quebec, Canada
| | - Savino Spadaro
- Anesthesia and Intensive Care Unit, Department of Translational Medicine, University of Ferrara, Ferrara, Italy
| | - Federico Longhini
- Anesthesia and Intensive Care Unit, Department of Medical and Surgical Sciences, "Magna Graecia" University, "Mater Domini" University Hospital, Catanzaro, Italy
| | - Antonino Giarratano
- Department of Surgical, Oncological and Oral Science (Di.Chir.On.S.), Section of Anaesthesia, Analgesia, Intensive Care and Emergency, Policlinico Paolo Giaccone, University of Palermo, Palermo, Italy
| | - Cinnella Gilda
- Department of Anesthesia and Intensive Care Medicine, University of Foggia, Policlinico Riuniti di Foggia, Foggia, Italy
| | - Tommaso Mauri
- Department of Anesthesia, Critical Care and Emergency, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Ca' Granda Ospedale Maggiore Policlinico Milan, Milano, Italy
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Paolo Navalesi
- Instiute of Anesthesia and Intensive Care, Padua University Hospital, Padova, Italy
- Department of Medicine - DIMED, University of Padua, Padova, Italy
| |
Collapse
|
7
|
Tracheobronchial Foreign Body Aspiration Diagnosed with Electrical Impedance Tomography. Case Rep Pediatr 2021; 2021:9951838. [PMID: 34765264 PMCID: PMC8577950 DOI: 10.1155/2021/9951838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Accepted: 09/24/2021] [Indexed: 11/24/2022] Open
Abstract
Background Foreign body aspiration (FBA) in children has a high morbidity, and early diagnosis is the key for preventing acute and chronic respiratory complications. To diagnose FBA, commonly used imaging modalities have limited negative predictive value, and rigid bronchoscopy remains as the gold standard. We present a case where the diagnosis of FBA was made in a novel way with electrical impedance tomography (EIT). Case Presentation. A 19-month-old previously healthy boy was admitted with a clinical diagnosis of respiratory failure secondary to bronchiolitis. Chest X-ray showed bilateral lung hyperinflation. He enrolled in a research study which used EIT to measure the effects of high flow nasal cannula (HFNC) on minute ventilation in children with bronchiolitis. On initiation, the patient had near-normal right lung ventilation (98%) and near-absent left lung ventilation (2%). We discontinued the study and alerted the medical team that we suspected FBA. Further imaging (lateral decubitus films and lung ultrasounds) was also obtained, but was not diagnostic. Rigid bronchoscopy was performed and showed a peanut occluding the left mainstem bronchus (LMB). The peanut was removed followed by complete resolution of the patient's symptoms. Conclusions We believe this is the first reported case of FBA diagnosed via EIT. EIT has been shown to be a useful but underutilized technology for diagnosing respiratory disease. While FBA remains a relatively common cause of morbidity and mortality in children less than age four, early diagnosis remains difficult and requires vigilance. This case illustrates the challenges of relying on chest films and ultrasound to assist with diagnosis and suggests that EIT in combination with a thorough history and physical exam can be used to confirm the presence of FBA.
Collapse
|
8
|
Son E, Jang J, Cho WH, Kim D, Yeo HJ. Successful lung transplantation after prone positioning in an ineligible donor: a case report. Gen Thorac Cardiovasc Surg 2021; 69:1352-1355. [PMID: 34159516 PMCID: PMC8218964 DOI: 10.1007/s11748-021-01676-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Accepted: 06/18/2021] [Indexed: 11/25/2022]
Abstract
Atelectasis is a reversible factor in hypoxemia among brain-dead donors. In ineligible donors, prone positioning reverses atelectasis and improves oxygenation. We present a successful lung transplantation after salvaging a previously unviable lung. A 37-year-old woman presented with acute pontine hemorrhage that progressed to brain death. The initial partial pressure of oxygen (PaO2)/fraction of inspired oxygen (FiO2) ratio of the donor’s lung was 342 mmHg. The PaO2/FiO2 ratio dropped to 49 mmHg due to atelectasis. There was no improvement despite recruitment maneuvers, bronchoscopy, and chest percussion. After placing the donor in the prone position for four hours, electrical impedance tomography showed improved atelectasis. The donor did not experience hemodynamic instability. The lung was transplanted into a patient with Kartagener’s syndrome with situs inversus. The surgical procedure was uneventful. He was successfully weaned from the mechanical ventilator on the second-day post-transplantation and was discharged from the hospital after 4 weeks.
Collapse
Affiliation(s)
- Eunjeong Son
- Department of Internal Medicine, Division of Pulmonary, Allergy, and Critical Care Medicine, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea
| | - Jinook Jang
- Department of Internal Medicine, Division of Pulmonary, Allergy, and Critical Care Medicine, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea
| | - Woo Hyun Cho
- Department of Internal Medicine, Division of Pulmonary, Allergy, and Critical Care Medicine, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea
| | - Dohyung Kim
- Department of Thoracic and Cardiovascular Surgery, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea
| | - Hye Ju Yeo
- Department of Internal Medicine, Division of Pulmonary, Allergy, and Critical Care Medicine, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea. .,Department of Pulmonology and Critical Care Medicine, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Geumo-ro 20, Beomeo-ri, Mulgeum-eup, Yangsan, Gyeongsangnam, 626-770, Republic of Korea.
| |
Collapse
|
9
|
Burey J, Guitard PG, Girard N, Cassiau F, Veber B, Clavier T. Impact of nursing care on lung functional residual capacity in acute respiratory distress syndrome patients. Nurs Crit Care 2021; 27:652-657. [PMID: 33860610 DOI: 10.1111/nicc.12630] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 03/19/2021] [Accepted: 03/22/2021] [Indexed: 12/30/2022]
Abstract
BACKGROUND The respiratory consequences of daily nursing care interventions in patients with acute respiratory distress syndrome (ARDS) are not clearly established. AIMS AND OBJECTIVES The main objective of this study was to assess the feasibility of alveolar collapse analysis by the measurement of lung impedance distribution technique during nursing care in patients with ARDS. DESIGN Prospective observational pilot physiologic study in a surgical intensive care unit of a tertiary care hospital including adult intubated patients with moderate-to-severe ARDS. METHODS Each patient was monitored for 12 hours using a chest impedance device. Daily care interventions studied were as follows: endotracheal suctioning, mouth care, bed-bathing, and blood sampling. The primary endpoint was the variation in end-expiratory lung impedance (reflecting functional residual capacity) before and 1, 5, 15, and 30 minutes after nursing care interventions. Data are presented as median (interquartile-range). RESULTS One hundred and eight events were collected in 18 patients. Endotracheal suctioning (n = 42), mouth care (n = 26), and bed-bathing (n = 23) induced a significant decrease in lung impedance after care: endotracheal suctioning (-40.0 [-53.8; -28.6]% at 1 minute [P < .001], -10.4 [-27.9; 1.8]% at 30 minutes [P = .03]; mouth care -17.9 [-45.4; -14.6]% at 1 minute [P < .001], -10.4 [-21.3; 3.4]% at 30 minutes [P = .01]; bed-bathing -40.2 [-53.5; -14.3]% at 1 minute [P < .001], -10.6 [-36.4; 1.6]% at 30 minutes [P = .01]). Blood sampling (n = 17) did not induce significant changes in lung impedance. CONCLUSIONS The lung impedance distribution technique during nursing care appears feasible in the majority of patients with ARDS. Some daily nursing care in ARDS patients (including bed-bathing and mouth care) resulted in a prolonged decrease in lung functional residual capacity and therefore could be associated with pulmonary de-recruitment. RELEVANCE TO CLINICAL PRACTICE A caregiver who has to assess the functional residual capacity of these patients should probably be informed of the schedules of the nursing care interventions.
Collapse
Affiliation(s)
- Julien Burey
- Department of Anesthesiology and Critical Care, Rouen University Hospital, Rouen, France
| | - Pierre-Gildas Guitard
- Department of Anesthesiology and Critical Care, Rouen University Hospital, Rouen, France
| | - Noémie Girard
- Gynecologic Cancer & Reconstructive Surgery unit, Department of surgery, Institut Curie, Paris, France
| | - Florence Cassiau
- Department of Anesthesiology and Critical Care, Rouen University Hospital, Rouen, France
| | - Benoît Veber
- Department of Anesthesiology and Critical Care, Rouen University Hospital, Rouen, France
| | - Thomas Clavier
- Department of Anesthesiology and Critical Care, Rouen University Hospital, Rouen, France.,Normandie Univ, UNIROUEN, INSERM U1096, Rouen, France
| |
Collapse
|
10
|
Lehmann M, Oehler B, Zuber J, Malzahn U, Walles T, Muellenbach RM, Roewer N, Kredel M. Redistribution of pulmonary ventilation after lung surgery detected with electrical impedance tomography. Acta Anaesthesiol Scand 2020; 64:517-525. [PMID: 31830306 DOI: 10.1111/aas.13525] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 10/09/2019] [Accepted: 11/04/2019] [Indexed: 12/25/2022]
Abstract
BACKGROUND Regional ventilation of the lung can be visualized by pulmonary electrical impedance tomography (EIT). The aim of this study was to examine the post-operative redistribution of regional ventilation after lung surgery dependent on the side of surgery and its association with forced vital capacity. METHODS In this prospective, observational cohort study 13 patients undergoing right and 13 patients undergoing left-sided open or video-thoracoscopic procedures have been investigated. Pre-operative measurements with EIT and spirometry were compared with data obtained 3 days post-operation. The center of ventilation (COV) within a 32 × 32 pixel matrix was calculated from EIT data. The transverse axis coordinate of COV, COVx (left/right), was modified to COVx' (ipsilateral/contralateral). Thus, COVx' shows a negative change if ventilation shifts contralateral independent of the side of surgery. This enabled testing with two-way ANOVA for repeated measurements (side, time). RESULTS The perioperative shift of COVx' was dependent on the side of surgery (P = .007). Ventilation shifted away from the side of surgery after the right-sided surgery (COVx'-1.97 pixel matrix points, P < .001), but not after the left-sided surgery (COVx'-0.61, P = .425). The forced vital capacity (%predicted) decreased from 94 (83-109)% (median [quartiles]; [left-sided]) and 89 (80-97)% (right-sided surgery) to 61 (59-66)% and 62 (40-72)% (P < .05), respectively. The perioperative changes in forced vital capacity (%predicted) were weakly associated with the shift of COVx'. CONCLUSION Only after right-sided lung surgery, EIT showed reduced ventilation on the side of surgery while vital capacity was markedly reduced in both groups.
Collapse
Affiliation(s)
- Martin Lehmann
- Department of Anaesthesia and Critical Care University Hospital of Würzburg Würzburg Germany
| | - Beatrice Oehler
- Wolfson Centre for Age-Related Diseases King's College London London UK
| | - Jonas Zuber
- Department of Anesthesia, General Intensive Care and Pain Management Medical University of Vienna Vienna Austria
| | - Uwe Malzahn
- Clinical Trials Center Würzburg University Hospital of Würzburg Würzburg Germany
| | - Thorsten Walles
- Department of Thoracic Surgery Magdeburg University Medicine Magdeburg Germany
| | - Ralf M. Muellenbach
- Department of Anesthesiology, Critical Care Medicine, Emergency Medicine and Pain Therapy ECMO Center Campus Kassel of the University of Southampton Kassel Germany
| | - Norbert Roewer
- Department of Anaesthesia and Critical Care University Hospital of Würzburg Würzburg Germany
| | - Markus Kredel
- Department of Anaesthesia and Critical Care University Hospital of Würzburg Würzburg Germany
| |
Collapse
|
11
|
Zhao Z, Chang MY, Frerichs I, Zhang JH, Chang HT, Gow CH, Möller K. Regional air trapping in acute exacerbation of obstructive lung diseases measured with electrical impedance tomography: a feasibility study. Minerva Anestesiol 2019; 86:172-180. [PMID: 31808658 DOI: 10.23736/s0375-9393.19.13732-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
BACKGROUND Since bronchial abnormalities often exhibit spatial non-uniformity which may be not correctly assessed by conventional global lung function measures, regional information may help to characterize the disease progress. We hypothesized that regional air trapping during mechanical ventilation could be characterized by regional end-expiratory flow (EEF) derived from electrical impedance tomography (EIT). METHODS Twenty-five patients suffering from chronic obstructive pulmonary disease (COPD grade 3 or 4) or severe asthma with acute exacerbation were examined prospectively. Patients were ventilated under assist-control mode. EIT measurements were conducted before and one hour after inhaled combined corticosteroid and long-acting β2 agonist, on two consecutive days. Regional EEF was calculated as derivative of relative impedance for every image pixel in the lung regions. The results were normalized to global flow values measured by the ventilator. RESULTS Regional and global EEF were highly correlated (P<0.00001) and regional effects of medication and disease progression were visible in the regional EEF maps. The sums of regional EEF in lung regions were 3.8 [2.0, 5.1] and 3.6 [1.9, 4.5] L/min in COPD patients before and after medication (median [lower, upper quartiles]; P=0.37). The corresponding values in asthma patients were 3.0 [2.5, 4.2] and 2.2 [1.7, 3.2] L/min (P<0.05). Histograms of regional EEF showed high spatial heterogeneity of EEF before medication. After one day of treatment, the histograms exhibited less heterogeneous and a decrease in EEF level. CONCLUSIONS Regional EEF characterizes air trapping and intrinsic PEEP, which could provide diagnostic information for monitoring the disease progress during treatment.
Collapse
Affiliation(s)
- Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.,Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Mei-Yun Chang
- Department of Internal Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Inéz Frerichs
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Center of Schleswig-Holstein Campus, Kiel, Germany
| | - Jia-Hao Zhang
- Department of Internal Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Hou-Tai Chang
- Department of Internal Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Chien-Hung Gow
- Department of Internal Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan - .,Department of Healthcare Information and Management, Ming-Chuan University, Taoyuan, Taiwan
| | - Knut Möller
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| |
Collapse
|
12
|
Lumb AB, Savic L, Horsford MR, Hodgson SR. Effects of tracheal intubation and tracheal tube position on regional lung ventilation: an observational study. Anaesthesia 2019; 75:359-365. [PMID: 32022912 DOI: 10.1111/anae.14919] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/17/2019] [Indexed: 11/30/2022]
Abstract
Anaesthesia and positive pressure ventilation cause ventral redistribution of regional ventilation, potentially caused by the tracheal tube. We used electrical impedance tomography to map regional ventilation during anaesthesia in 10 patients with and without a tracheal tube. We recorded impedance data in subjects who were awake, during bag-mask ventilation, with the tracheal tube positioned normally, rotated 90° to each side and advanced until in an endobronchial position. We recorded the following measurements: ventilation of the right lung (proportion, %); centre of ventilation (100% = entirely ventral); global inhomogeneity (0% = homogenous); and regional ventilation delay, an index of temporal heterogeneity. We compared the results using Student's t-tests. Relative to subjects who were awake, anaesthesia with bag-mask ventilation reduced right-sided ventilation by 5.6% (p = 0.002), reduced regional ventilation delay by 1.6% (p = 0.025), and moved the centre of ventilation ventrally from 51.4% to 58.2% (p = 0.0001). Tracheal tube ventilation caused a further centre of ventilation increase of 1.3% (p = 0.009). With the tube near the carina, right-sided ventilation increased by 3.2% (p = 0.031) and regional ventilation delay by 2.8% (p = 0.049). Tube rotation caused a 1.6% increase in right-sided ventilation compared with normal position (p = 0.043 left and p = 0.031 right). Global inhomogeneity remained mostly unchanged. Ventral ventilation with positive pressure ventilation occurred with bag-mask ventilation, but was exacerbated by a tracheal tube. Tube position influenced ventilation of the right and left lungs, while ventilation overall remained homogenous. Tube rotation in either direction resulted in ventilation patterns being closer to when awake than either bag-mask ventilation or a normally positioned tube. These results suggest that even ideal tube positioning cannot avoid the ventral shift in ventilation.
Collapse
Affiliation(s)
- A B Lumb
- Department of Anaesthesia, St James's University Hospital, Leeds, UK.,Leeds Institute of Biological and Clinical Sciences, University of Leeds, UK
| | - L Savic
- Department of Anaesthesia, St James's University Hospital, Leeds, UK
| | - M R Horsford
- Leeds Institute of Biological and Clinical Sciences, University of Leeds, UK
| | - S R Hodgson
- Leeds Institute of Biological and Clinical Sciences, University of Leeds, UK
| |
Collapse
|
13
|
Spinelli E, Mauri T, Fogagnolo A, Scaramuzzo G, Rundo A, Grieco DL, Grasselli G, Volta CA, Spadaro S. Electrical impedance tomography in perioperative medicine: careful respiratory monitoring for tailored interventions. BMC Anesthesiol 2019; 19:140. [PMID: 31390977 PMCID: PMC6686519 DOI: 10.1186/s12871-019-0814-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Accepted: 07/29/2019] [Indexed: 01/26/2023] Open
Abstract
BACKGROUND Electrical impedance tomography (EIT) is a non-invasive radiation-free monitoring technique that provides images based on tissue electrical conductivity of the chest. Several investigations applied EIT in the context of perioperative medicine, which is not confined to the intraoperative period but begins with the preoperative assessment and extends to postoperative follow-up. MAIN BODY EIT could provide careful respiratory monitoring in the preoperative assessment to improve preparation for surgery, during anaesthesia to guide optimal ventilation strategies and to monitor the hemodynamic status and in the postoperative period for early detection of respiratory complications. Moreover, EIT could further enhance care of patients undergoing perioperative diagnostic procedures. This narrative review summarizes the latest evidence on the application of this technique to the surgical patient, focusing also on possible future perspectives. CONCLUSIONS EIT is a promising technique for the perioperative assessment of surgical patients, providing tailored adaptive respiratory and haemodynamic monitoring. Further studies are needed to address the current technological limitations, confirm the findings and evaluate which patients can benefit more from this technology.
Collapse
Affiliation(s)
- Elena Spinelli
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Tommaso Mauri
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Alberto Fogagnolo
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Gaetano Scaramuzzo
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Annalisa Rundo
- UOC Anestesia e Rianimazione, Polo ospedaliero Belcolle ASL, Viterbo, Italy
| | - Domenico Luca Grieco
- Department of Anesthesiology and Intensive Care Medicine, Catholic University of the Sacred Heart, Fondazione "Policlinico Universitario A. Gemelli", Rome, Italy
| | - Giacomo Grasselli
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Carlo Alberto Volta
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Savino Spadaro
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy.
| |
Collapse
|
14
|
Electrical Impedance Tomography for Cardio-Pulmonary Monitoring. J Clin Med 2019; 8:jcm8081176. [PMID: 31394721 PMCID: PMC6722958 DOI: 10.3390/jcm8081176] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 08/05/2019] [Accepted: 08/06/2019] [Indexed: 12/14/2022] Open
Abstract
Electrical impedance tomography (EIT) is a bedside monitoring tool that noninvasively visualizes local ventilation and arguably lung perfusion distribution. This article reviews and discusses both methodological and clinical aspects of thoracic EIT. Initially, investigators addressed the validation of EIT to measure regional ventilation. Current studies focus mainly on its clinical applications to quantify lung collapse, tidal recruitment, and lung overdistension to titrate positive end-expiratory pressure (PEEP) and tidal volume. In addition, EIT may help to detect pneumothorax. Recent studies evaluated EIT as a tool to measure regional lung perfusion. Indicator-free EIT measurements might be sufficient to continuously measure cardiac stroke volume. The use of a contrast agent such as saline might be required to assess regional lung perfusion. As a result, EIT-based monitoring of regional ventilation and lung perfusion may visualize local ventilation and perfusion matching, which can be helpful in the treatment of patients with acute respiratory distress syndrome (ARDS).
Collapse
|
15
|
Zhao Z, Yun PJ, Kuo YL, Fu F, Dai M, Frerichs I, Möller K. Comparison of different functional EIT approaches to quantify tidal ventilation distribution. Physiol Meas 2018; 39:01NT01. [DOI: 10.1088/1361-6579/aa9eb4] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
16
|
Santos SA, Wembers CC, Horst K, Pfeifer R, Simon TP, Pape HC, Hildebrand F, Czaplik M, Leonhardt S, Teichmann D. Monitoring lung contusion in a porcine polytrauma model using EIT: an application study. Physiol Meas 2017. [DOI: 10.1088/1361-6579/aa7985] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
17
|
Hochhausen N, Dohmeier H, Rossaint R, Czaplik M. Monitoring of cardiac output and lung ventilation by Electrical Impedance Tomography in a porcine model of acute lung injury. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2017:352-355. [PMID: 29059883 DOI: 10.1109/embc.2017.8036835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Adequate medical treatment of the Acute Respiratory Distress Syndrome is still challenging since patient-individual aspects have to be taken into account. Lung protective ventilation and hemodynamic stability have always been two of the most crucial aims of intensive care therapy. For both aspects, a continuous - preferably non-invasive - monitoring is desirable that is available at the bedside. Unfortunately, there is no technique clinically established yet, that provides both measurement of cardiac stroke volume and ventilation dynamics in real-time. Electrical Impedance Tomography (EIT) is a promising technique to close this gap. The aim of the study was to investigate if stroke volume can be estimated by a self-developed software using EIT-based image analysis. In addition, two EIT-derived parameters, namely Global Inhomogeneity Index (GII) and Impedance Ratio (IR), were calculated to evaluate homogeneity of air distribution. Experimental acute lung injury (ALI) was provoked in seven female pigs (German Landrace) by lipopolysaccharide (LPS). All animals suffered from experimental ALI 3 to 4 hours after LPS infusion. At defined time points, respiratory and hemodynamic parameters, blood gas analyses and EIT-recordings were performed. Eight hours after ALI, animals were euthanized. Stroke volume, derived from pulmonary artery catheter (PAC), decreased continuously up to four hours after ALI. Then, stroke volume increased slightly. Stroke volume, derived from the self-developed tool, showed the same characteristics (p=0.047, r = 0.365). In addition to the GII and IR individually, both classified scores showed a high correlation with the Horowitz Index, defined as paO2/FiO2. To conclude, EIT-derived measures enabled a reliable estimation of cardiac stroke volume and regional distribution of ventilation.
Collapse
|
18
|
Kobylianskii J, Murray A, Brace D, Goligher E, Fan E. Electrical impedance tomography in adult patients undergoing mechanical ventilation: A systematic review. J Crit Care 2016; 35:33-50. [PMID: 27481734 DOI: 10.1016/j.jcrc.2016.04.028] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Revised: 04/25/2016] [Accepted: 04/27/2016] [Indexed: 01/20/2023]
Abstract
PURPOSE The purpose of the study is to systematically review and summarize current literature concerning the validation and application of electrical impedance tomography (EIT) in mechanically ventilated adult patients. MATERIALS AND METHODS An electronic search of MEDLINE, EMBASE, CINAHL, Cochrane Central Register of Controlled Trials, and the Web of Science was performed up to June 2014. Studies investigating the use of EIT in an adult human patient population treated with mechanical ventilation (MV) were included. Data extracted included study objectives, EIT details, interventions, MV protocol, validation and comparators, population characteristics, and key findings. RESULTS Of the 67 included studies, 35 had the primary objective of validating EIT measures including regional ventilation distribution, lung volume, regional respiratory mechanics, and nonventilatory parameters. Thirty-two studies had the primary objective of applying EIT to monitor the response to therapeutic MV interventions including change in ventilation mode, patient repositioning, endotracheal suctioning, recruitment maneuvers, and change in positive end-expiratory pressure. CONCLUSIONS In adult patients, EIT has been successfully validated for assessing ventilation distribution, measuring changes in lung volume, studying regional respiratory mechanics, and investigating nonventilatory parameters. Electrical impedance tomography has also been demonstrated to be useful in monitoring regional respiratory system changes during MV interventions, although existing literature lacks clinical outcome evidence.
Collapse
Affiliation(s)
- Jane Kobylianskii
- School of Medicine, Queen's University, Kingston, Canada; Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
| | - Alistair Murray
- Schulich School of Medicine & Dentistry, Western University, London, Canada; Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
| | - Debbie Brace
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
| | - Ewan Goligher
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
| | - Eddy Fan
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada.
| |
Collapse
|
19
|
Jamshed N, Ozair FF, Ekka M, Aggarwal P. Does chest radiograph confirm tracheal intubation? Am J Emerg Med 2014; 32:96-7. [DOI: 10.1016/j.ajem.2013.10.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2013] [Accepted: 10/05/2013] [Indexed: 12/01/2022] Open
|
20
|
STEINMANN D, ENGEHAUSEN M, STILLER B, GUTTMANN J. Electrical impedance tomography for verification of correct endotracheal tube placement in paediatric patients: a feasibility study. Acta Anaesthesiol Scand 2013; 57:881-7. [PMID: 23750708 DOI: 10.1111/aas.12143] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/14/2013] [Indexed: 10/26/2022]
Abstract
BACKGROUND Endotracheal tubes (ETTs) are frequently used in paediatric anaesthesia. Correct placement is crucial. The aim of this study was to evaluate electrical impedance tomography (EIT) for guiding and confirmation of paediatric ETT placement. In a retrospective analysis of stored EIT data, distribution of ventilation between left and right lung was used to verify correct paediatric ETT placement. METHODS Left and right lung ventilation was studied by EIT in 18 paediatric patients (median age: 53 months) requiring anaesthesia and endotracheal intubation. EIT was recorded before induction of anaesthesia, during mask ventilation, during ETT placement (including deliberate mainstem intubation), and after ETT repositioning according to the formula: ETT intubation depth (cm) = 3× ETT internal diameter (mm) or the mainstem intubation method (withdrawing the ETT 2 cm). Final ETT position was confirmed by fluoroscopy. RESULTS Following deliberate mainstem intubation, distribution of ventilation to the right lung was unequivocally demonstrated by EIT. Homogeneous distribution of ventilation between left and right lung monitored with EIT correlated in each patient with correct endotracheal ETT placement. The distribution of left and right lung ventilation differed significantly (P < 0.05) between the initial two-lung ventilation and subsequent right one-lung ventilation, and between right one-lung and subsequent two-lung ventilation according to auscultation and the final ETT position, respectively. In one patient, ETT was misplaced within the oesophagus which was also obvious from the EIT record. CONCLUSION This study demonstrates that EIT enables non-invasive recognition of correct ETT placement. Homogeneous right-left-lung ventilation is an indicator for correct ETT placement.
Collapse
Affiliation(s)
- D. STEINMANN
- Department of Occupational Medicine; University Medical Center Freiburg; Freiburg; Germany
| | - M. ENGEHAUSEN
- Department of Anaesthesia and Critical Care Medicine; Ortenau Clinical Center; Offenburg; Germany
| | - B. STILLER
- Department of Congenital Heart Disease; University Heart Center Freiburg; Freiburg; Germany
| | - J. GUTTMANN
- Department of Anaesthesia and Critical Care Medicine; University Medical Center Freiburg; Freiburg; Germany
| |
Collapse
|
21
|
Schmölzer GM, Bhatia R, Davis PG, Tingay DG. A comparison of different bedside techniques to determine endotracheal tube position in a neonatal piglet model. Pediatr Pulmonol 2013; 48:138-45. [PMID: 22615185 DOI: 10.1002/ppul.22580] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2012] [Accepted: 03/06/2012] [Indexed: 12/22/2022]
Abstract
RATIONALE Endotracheal tube (ETT) malposition is common and an increasing number of non-invasive techniques to aid rapid identification of tube position are available. Electrical impedance tomography (EIT) is advocated as a tool to monitor ventilation. OBJECTIVE This study aimed to compare EIT with five other non-invasive techniques for identifying ETT position in a piglet model. METHODOLOGY Six saline lavage surfactant-depleted piglets were studied. Periods of ventilation with ETT placed in the oesophagus or a main bronchus (MB) were compared with an appropriately placed mid-tracheal ETT. Colorimetric end-tidal CO(2) (Pedi-Cap®), SpO(2) and heart rate, tidal volume (${\rm V}_{{\rm T}_{{\rm ao}} } $) using a hot-wire anemometer at the airway opening, tidal volume using respiratory inductive plethysmography (${\rm V}_{{\rm T}_{{\rm RIP}} } $) and regional tidal ventilation within each hemithorax (EIT) were measured. RESULTS Oesophageal ventilation: Pedi-Cap® demonstrated absence of color change. ${\rm V}_{{\rm T}_{{\rm ao}} } $, ${\rm V}_{{\rm T}_{{\rm RIP}} } $, and EIT correctly demonstrated no tidal ventilation. SpO(2) decreased from mean (SD) 96 (2)% to 74 (12)% (P < 0.05; Bonferroni post-test), without heart rate change. MB ventilation: SpO(2) , heart rate and Pedi-Cap® were unchanged compared with mid-tracheal position. ${\rm V}_{{\rm T}_{{\rm ao}} } $ and ${\rm V}_{{\rm T}_{{\rm RIP}} } $ decreased from a mean (SD) 10.8 (5.6) ml/kg and 14.6 (6.2) ml/kg to 5.5 (1.9) ml/kg and 6.4 (2.6) ml/kg (both P < 0.05; Bonferroni post-test). EIT identified the side of MB ventilation, with a mean (SD) 95 (3)% reduction in tidal volume in the unventilated lung. CONCLUSIONS EIT not only correctly identified oesophageal ventilation but also localized the side of MB ventilation. At present, no one technique is without limitations and clinicians should utilize a combination in addition to clinical judgement.
Collapse
Affiliation(s)
- Georg M Schmölzer
- Neonatal Research, Murdoch Childrens Research Institute, Melbourne, Australia.
| | | | | | | |
Collapse
|
22
|
Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring? Intensive Care Med 2012; 38:1917-29. [DOI: 10.1007/s00134-012-2684-z] [Citation(s) in RCA: 87] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2011] [Accepted: 08/08/2012] [Indexed: 01/08/2023]
|
23
|
Vogt B, Pulletz S, Elke G, Zhao Z, Zabel P, Weiler N, Frerichs I. Spatial and temporal heterogeneity of regional lung ventilation determined by electrical impedance tomography during pulmonary function testing. J Appl Physiol (1985) 2012; 113:1154-61. [PMID: 22898553 DOI: 10.1152/japplphysiol.01630.2011] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Electrical impedance tomography (EIT) is a functional imaging modality capable of tracing continuously regional pulmonary gas volume changes. The aim of our study was to determine if EIT was able to assess spatial and temporal heterogeneity of ventilation during pulmonary function testing in 14 young (37 ± 10 yr, mean age ± SD) and 12 elderly (71 ± 9 yr) subjects without lung disease and in 33 patients with chronic obstructive pulmonary disease (71 ± 9 yr). EIT and spirometry examinations were performed during tidal breathing and a forced vital capacity (FVC) maneuver preceded by full inspiration to total lung capacity. Regional inspiratory vital capacity (IVC); FVC; forced expiratory volume in 1 s (FEV(1)); FEV(1)/FVC; times required to expire 25%, 50%, 75%, and 90% of FVC (t(25), t(50), t(75), t(90)); and tidal volume (V(T)) were determined in 912 EIT image pixels in the chest cross section. Coefficients of variation (CV) were calculated from all pixel values of IVC, FVC, FEV(1), and V(T) to characterize the ventilation heterogeneity. The highest values were found in patients, and no differences existed between the healthy young and elderly subjects. Receiver-operating characteristics curves showed that CV of regional IVC, FVC, FEV(1), and V(T) discriminated the young and elderly subjects from the patients. Frequency distributions of pixel FEV(1)/FVC, t(25), t(50), t(75), and t(90) identified the highest ventilation heterogeneity in patients but distinguished also the healthy young from the elderly subjects. These results indicate that EIT may provide additional information during pulmonary function testing and identify pathologic and age-related spatial and temporal heterogeneity of regional lung function.
Collapse
Affiliation(s)
- Barbara Vogt
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Arnold-Heller-Strasse 3, Kiel, Germany
| | | | | | | | | | | | | |
Collapse
|
24
|
Leonhardt S, Pikkemaat R, Stenqvist O, Lundin S. Electrical Impedance Tomography for hemodynamic monitoring. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2012:122-125. [PMID: 23365847 DOI: 10.1109/embc.2012.6345886] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Electrical Impedance Tomography (EIT) is a known technique to monitor impedance changes in a cross-section of a body segment, which recently gained increasing interest for regional ventilation monitoring. In this paper, we focus on hemodynamic monitoring using EIT. Past and ongoing research activities to obtain cardiac related signals and regional perfusion information from EIT image streams are summarized. Finally, we present some preliminary results on stroke volume estimation using EIT.
Collapse
Affiliation(s)
- Steffen Leonhardt
- Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, D-52074 Aachen, Germany
| | | | | | | |
Collapse
|
25
|
de Bellis M, Accardo R, Di Maio M, Lamanna C, Rossi GB, Pace MC, Romano V, Rocco G. Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery?☆. Eur J Cardiothorac Surg 2011; 40:912-6. [DOI: 10.1016/j.ejcts.2011.01.070] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2010] [Revised: 01/25/2011] [Accepted: 01/31/2011] [Indexed: 11/28/2022] Open
|
26
|
Abstract
PURPOSE OF REVIEW Electrical impedance tomography (EIT) is an attractive method of monitoring patients during mechanical ventilation because it can provide a noninvasive continuous image of pulmonary impedance, which indicates the distribution of ventilation. This article will discuss ongoing research on EIT, with a focus on methodological aspects and limitations and novel approaches in terms of pathophysiology, diagnosis and therapeutic advancements. RECENT FINDINGS EIT enables the detection of regional distribution of alveolar ventilation and, thus, the quantification of local inhomogeneities in lung mechanics. By detecting recruitment and derecruitment, a positive end-expiratory pressure level at which tidal ventilation is relatively homogeneous in all lung regions can be defined. Additionally, different approaches to characterize the temporal local behaviour of lung tissue during ventilation have been proposed, which adds important information. SUMMARY There is growing evidence that supports EIT usage as a bedside measure to individually optimize ventilator settings in critically ill patients in order to prevent ventilator-induced lung injury. A standardization of current approaches to analyse and interpret EIT data is required in order to facilitate the clinical implementation.
Collapse
|
27
|
Corley A, Caruana LR, Barnett AG, Tronstad O, Fraser JF. Oxygen delivery through high-flow nasal cannulae increase end-expiratory lung volume and reduce respiratory rate in post-cardiac surgical patients. Br J Anaesth 2011; 107:998-1004. [PMID: 21908497 DOI: 10.1093/bja/aer265] [Citation(s) in RCA: 296] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND High-flow nasal cannulae (HFNCs) create positive oropharyngeal airway pressure, but it is unclear how their use affects lung volume. Electrical impedance tomography allows the assessment of changes in lung volume by measuring changes in lung impedance. Primary objectives were to investigate the effects of HFNC on airway pressure (P(aw)) and end-expiratory lung volume (EELV) and to identify any correlation between the two. Secondary objectives were to investigate the effects of HFNC on respiratory rate, dyspnoea, tidal volume, and oxygenation; and the interaction between BMI and EELV. METHODS Twenty patients prescribed HFNC post-cardiac surgery were investigated. Impedance measures, P(aw), ratio, respiratory rate, and modified Borg scores were recorded first on low-flow oxygen and then on HFNC. RESULTS A strong and significant correlation existed between P(aw) and end-expiratory lung impedance (EELI) (r=0.7, P<0.001). Compared with low-flow oxygen, HFNC significantly increased EELI by 25.6% [95% confidence interval (CI) 24.3, 26.9] and P(aw) by 3.0 cm H(2)O (95% CI 2.4, 3.7). Respiratory rate reduced by 3.4 bpm (95% CI 1.7, 5.2) with HFNC use, tidal impedance variation increased by 10.5% (95% CI 6.1, 18.3), and ratio improved by 30.6 mm Hg (95% CI 17.9, 43.3). A trend towards HFNC improving subjective dyspnoea scoring (P=0.023) was found. Increases in EELI were significantly influenced by BMI, with larger increases associated with higher BMIs (P<0.001). CONCLUSIONS This study suggests that HFNCs reduce respiratory rate and improve oxygenation by increasing both EELV and tidal volume and are most beneficial in patients with higher BMIs.
Collapse
Affiliation(s)
- A Corley
- Critical Care Research Group, The Prince Charles Hospital and University of Queensland, Rode Rd, Chermside, QLD 4032, Australia.
| | | | | | | | | |
Collapse
|
28
|
Reifferscheid F, Elke G, Pulletz S, Gawelczyk B, Lautenschläger I, Steinfath M, Weiler N, Frerichs I. Regional ventilation distribution determined by electrical impedance tomography: reproducibility and effects of posture and chest plane. Respirology 2011; 16:523-31. [PMID: 21261780 DOI: 10.1111/j.1440-1843.2011.01929.x] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND AND OBJECTIVE Reliable assessment of regional lung ventilation and good reproducibility of electrical impedance tomography (EIT) data are the prerequisites for the future application of EIT in a clinical setting. The aims of our study were to determine (i) the reproducibility of repeated EIT measurements and (ii) the effect of the studied transverse chest plane on ventilation distribution in different postures. METHODS Ten healthy adult subjects were studied in three postures on two separate days. EIT and spirometric data were obtained during tidal breathing and slow vital capacity (VC) manoeuvres. EIT data were acquired in two chest planes at 13 scans/s. Reproducibility of EIT findings was assessed by Bland-Altman analysis and Pearson correlation in 16 regions of interest in each plane. Regional ventilation distribution during tidal breathing and deep expiration was determined as fractional ventilation in four quadrants of the studied chest cross-sections. RESULTS Our study showed a good reproducibility of EIT measurements repeated after an average time interval of 8 days. Global tidal volumes and VCs determined by spirometry on separate days were not significantly different. Regional ventilation in chest quadrants assessed by EIT was also unaffected. Posture exerted a significant effect on ventilation distribution among the chest quadrants during spontaneous breathing and deep expiration in both planes. The spatial distribution patterns in the two planes were not identical. CONCLUSIONS We conclude that regional EIT ventilation findings are reproducible and recommend that the EIT examination location on the chest is carefully chosen especially during repeated measurements and follow-up.
Collapse
Affiliation(s)
- Florian Reifferscheid
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein-Campus Kiel, Kiel, Germany
| | | | | | | | | | | | | | | |
Collapse
|
29
|
Riera J, Riu PJ, Casan P, Masclans JR. [Electrical impedance tomography in acute lung injury]. Med Intensiva 2011; 35:509-17. [PMID: 21680060 DOI: 10.1016/j.medin.2011.05.005] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2011] [Revised: 05/01/2011] [Accepted: 05/03/2011] [Indexed: 01/18/2023]
Abstract
Electrical impedance tomography has been described as a new method of monitoring critically ill patients on mechanical ventilation. It has recently gained special interest because of its applicability for monitoring ventilation and pulmonary perfusion. Its bedside and continuous implementation, and the fact that it is a non-ionizing and non-invasive technique, makes it an extremely attractive measurement tool. Likewise, given its ability to assess the regional characteristics of lung structure, it could be considered an ideal monitoring tool in the heterogeneous lung with acute lung injury. This review explains the physical concept of bioimpedance and its clinical application, and summarizes the scientific evidence published to date with regard to the implementation of electrical impedance tomography as a method for monitoring ventilation and perfusion, mainly in the patient with acute lung injury, and other possible applications of the technique in the critically ill patient. The review also summarizes the limitations of the technique and its potential areas of future development.
Collapse
Affiliation(s)
- J Riera
- Servicio de Medicina Intensiva, Hospital Universitario Vall d'Hebron, Vall d'Hebron Institut de Recerca, Universitat Autònoma de Barcelona, Barcelona, España.
| | | | | | | |
Collapse
|
30
|
|
31
|
Current World Literature. Curr Opin Anaesthesiol 2010; 23:116-20. [DOI: 10.1097/aco.0b013e3283357df6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
32
|
Evaluation of an electrical impedance tomography-based global inhomogeneity index for pulmonary ventilation distribution. Intensive Care Med 2009; 35:1900-6. [DOI: 10.1007/s00134-009-1589-y] [Citation(s) in RCA: 142] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2009] [Accepted: 06/25/2009] [Indexed: 10/20/2022]
|
33
|
|
34
|
Costa ELV, Gonzalez Lima R, Amato MBP. Electrical Impedance Tomography. Intensive Care Med 2009. [DOI: 10.1007/978-0-387-92278-2_38] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|