1
|
Adenis V, Partouche E, Stahl P, Gnansia D, Huetz C, Edeline JM. Asymmetric pulses delivered by a cochlear implant allow a reduction in evoked firing rate and in spatial activation in the guinea pig auditory cortex. Hear Res 2024; 447:109027. [PMID: 38723386 DOI: 10.1016/j.heares.2024.109027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 04/30/2024] [Accepted: 05/02/2024] [Indexed: 05/25/2024]
Abstract
Despite that fact that the cochlear implant (CI) is one of the most successful neuro-prosthetic devices which allows hearing restoration, several aspects still need to be improved. Interactions between stimulating electrodes through current spread occurring within the cochlea drastically limit the number of discriminable frequency channels and thus can ultimately result in poor speech perception. One potential solution relies on the use of new pulse shapes, such as asymmetric pulses, which can potentially reduce the current spread within the cochlea. The present study characterized the impact of changing electrical pulse shapes from the standard biphasic symmetric to the asymmetrical shape by quantifying the evoked firing rate and the spatial activation in the guinea pig primary auditory cortex (A1). At a fixed charge, the firing rate and the spatial activation in A1 decreased by 15 to 25 % when asymmetric pulses were used to activate the auditory nerve fibers, suggesting a potential reduction of the spread of excitation inside the cochlea. A strong "polarity-order" effect was found as the reduction was more pronounced when the first phase of the pulse was cathodic with high amplitude. These results suggest that the use of asymmetrical pulse shapes in clinical settings can potentially reduce the channel interactions in CI users.
Collapse
Affiliation(s)
- V Adenis
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - E Partouche
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - P Stahl
- Oticon Medical, Vallauris, France
| | | | - C Huetz
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - J-M Edeline
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France.
| |
Collapse
|
2
|
Partouche E, Adenis V, Stahl P, Huetz C, Edeline JM. What Is the Benefit of Ramped Pulse Shapes for Activating Auditory Cortex Neurons? An Electrophysiological Study in an Animal Model of Cochlear Implant. Brain Sci 2023; 13:brainsci13020250. [PMID: 36831793 PMCID: PMC9954719 DOI: 10.3390/brainsci13020250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 01/19/2023] [Accepted: 01/30/2023] [Indexed: 02/04/2023] Open
Abstract
In all commercial cochlear implant (CI) devices, the activation of auditory nerve fibers is performed with rectangular pulses that have two phases of opposite polarity. Recently, several papers proposed that ramped pulse shapes could be an alternative shape for efficiently activating auditory nerve fibers. Here, we investigate whether ramped pulse shapes can activate auditory cortex (ACx) neurons in a more efficient way than the classical rectangular pulses. Guinea pigs were implanted with CI devices and responses of ACx neurons were tested with rectangular pulses and with four ramped pulse shapes, with a first-phase being either cathodic or anodic. The thresholds, i.e., the charge level necessary for obtaining significant cortical responses, were almost systematically lower with ramped pulses than with rectangular pulses. The maximal firing rate (FR) elicited by the ramped pulses was higher than with rectangular pulses. As the maximal FR occurred with lower charge levels, the dynamic range (between threshold and the maximal FR) was not modified. These effects were obtained with cathodic and anodic ramped pulses. By reducing the charge levels required to activate ACx neurons, the ramped pulse shapes should reduce charge consumption and should contribute to more battery-efficient CI devices in the future.
Collapse
Affiliation(s)
- Elie Partouche
- Jean-Marc Edeline Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, Campus CEA Saclay, Route de la Rotonde Bâtiment 151, 91400 Saclay, France
| | - Victor Adenis
- Jean-Marc Edeline Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, Campus CEA Saclay, Route de la Rotonde Bâtiment 151, 91400 Saclay, France
| | - Pierre Stahl
- Departement of Scientific and Clinical Research, Oticon Medical, 06220 Vallauris, France
| | - Chloé Huetz
- Jean-Marc Edeline Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, Campus CEA Saclay, Route de la Rotonde Bâtiment 151, 91400 Saclay, France
| | - Jean-Marc Edeline
- Jean-Marc Edeline Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, Campus CEA Saclay, Route de la Rotonde Bâtiment 151, 91400 Saclay, France
- Correspondence:
| |
Collapse
|
3
|
Souffi S, Varnet L, Zaidi M, Bathellier B, Huetz C, Edeline JM. Reduction in sound discrimination in noise is related to envelope similarity and not to a decrease in envelope tracking abilities. J Physiol 2023; 601:123-149. [PMID: 36373184 DOI: 10.1113/jp283526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 11/08/2022] [Indexed: 11/15/2022] Open
Abstract
Humans and animals constantly face challenging acoustic environments, such as various background noises, that impair the detection, discrimination and identification of behaviourally relevant sounds. Here, we disentangled the role of temporal envelope tracking in the reduction in neuronal and behavioural discrimination between communication sounds in situations of acoustic degradations. By collecting neuronal activity from six different levels of the auditory system, from the auditory nerve up to the secondary auditory cortex, in anaesthetized guinea-pigs, we found that tracking of slow changes of the temporal envelope is a general functional property of auditory neurons for encoding communication sounds in quiet conditions and in adverse, challenging conditions. Results from a go/no-go sound discrimination task in mice support the idea that the loss of distinct slow envelope cues in noisy conditions impacted the discrimination performance. Together, these results suggest that envelope tracking is potentially a universal mechanism operating in the central auditory system, which allows the detection of any between-stimulus difference in the slow envelope and thus copes with degraded conditions. KEY POINTS: In quiet conditions, envelope tracking in the low amplitude modulation range (<20 Hz) is correlated with the neuronal discrimination between communication sounds as quantified by mutual information from the cochlear nucleus up to the auditory cortex. At each level of the auditory system, auditory neurons retain their abilities to track the communication sound envelopes in situations of acoustic degradation, such as vocoding and the addition of masking noises up to a signal-to-noise ratio of -10 dB. In noisy conditions, the increase in between-stimulus envelope similarity explains the reduction in both behavioural and neuronal discrimination in the auditory system. Envelope tracking can be viewed as a universal mechanism that allows neural and behavioural discrimination as long as the temporal envelope of communication sounds displays some differences.
Collapse
Affiliation(s)
- Samira Souffi
- Paris-Saclay Institute of Neuroscience (Neuro-PSI, UMR 9197), CNRS - Université Paris-Saclay, Saclay, France
| | - Léo Varnet
- Laboratoire des systèmes perceptifs, UMR CNRS 8248, Département d'Etudes Cognitives, Ecole Normale Supérieure, Université Paris Sciences & Lettres, Paris, France
| | - Meryem Zaidi
- Paris-Saclay Institute of Neuroscience (Neuro-PSI, UMR 9197), CNRS - Université Paris-Saclay, Saclay, France
| | - Brice Bathellier
- Institut de l'Audition, Institut Pasteur, Université de Paris, INSERM, Paris, France
| | - Chloé Huetz
- Paris-Saclay Institute of Neuroscience (Neuro-PSI, UMR 9197), CNRS - Université Paris-Saclay, Saclay, France
| | - Jean-Marc Edeline
- Paris-Saclay Institute of Neuroscience (Neuro-PSI, UMR 9197), CNRS - Université Paris-Saclay, Saclay, France
| |
Collapse
|
4
|
Partouche E, Adenis V, Gnansia D, Stahl P, Edeline JM. Increased Threshold and Reduced Firing Rate of Auditory Cortex Neurons after Cochlear Implant Insertion. Brain Sci 2022; 12:brainsci12020205. [PMID: 35203968 PMCID: PMC8870646 DOI: 10.3390/brainsci12020205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 01/25/2022] [Accepted: 01/28/2022] [Indexed: 12/10/2022] Open
Abstract
The cochlear implant (CI) is the most successful neuroprosthesis allowing thousands of patients with profound hearing loss to recover speech understanding. Recently, cochlear implants have been proposed to subjects with residual hearing and, in these cases, shorter CIs were implanted. To be successful, it is crucial to preserve the patient’s remaining hearing abilities after the implantation. Here, we quantified the effects of CI insertion on the responses of auditory cortex neurons in anesthetized guinea pigs. The responses of auditory cortex neurons were determined before and after the insertion of a 300 µm diameter CI (six stimulating electrodes, length 6 mm). Immediately after CI insertion there was a 5 to 15 dB increase in the threshold for cortical neurons from the middle to the high frequencies, accompanied by a decrease in the evoked firing rate. Analyzing the characteristic frequency (CF) values revealed that in large number of cases, the CFs obtained after insertion were lower than before. These effects were not detected in the control animals. These results indicate that there is a small but immediate cortical hearing loss after CI insertion, even with short length CIs. Therefore, efforts should be made to minimize the damages during CI insertion to preserve the cortical responses to acoustic stimuli.
Collapse
Affiliation(s)
- Elie Partouche
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, 91400 Saclay, France; (E.P.); (V.A.)
| | - Victor Adenis
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, 91400 Saclay, France; (E.P.); (V.A.)
| | - Dan Gnansia
- Department of Scientific and Clinical Research, Oticon Medical, 06224 Vallauris, France; (D.G.); (P.S.)
| | - Pierre Stahl
- Department of Scientific and Clinical Research, Oticon Medical, 06224 Vallauris, France; (D.G.); (P.S.)
| | - Jean-Marc Edeline
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, 91400 Saclay, France; (E.P.); (V.A.)
- Correspondence:
| |
Collapse
|
5
|
Robustness to Noise in the Auditory System: A Distributed and Predictable Property. eNeuro 2021; 8:ENEURO.0043-21.2021. [PMID: 33632813 PMCID: PMC7986545 DOI: 10.1523/eneuro.0043-21.2021] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 02/17/2021] [Accepted: 02/17/2021] [Indexed: 12/30/2022] Open
Abstract
Background noise strongly penalizes auditory perception of speech in humans or vocalizations in animals. Despite this, auditory neurons are still able to detect communications sounds against considerable levels of background noise. We collected neuronal recordings in cochlear nucleus (CN), inferior colliculus (IC), auditory thalamus, and primary and secondary auditory cortex in response to vocalizations presented either against a stationary or a chorus noise in anesthetized guinea pigs at three signal-to-noise ratios (SNRs; −10, 0, and 10 dB). We provide evidence that, at each level of the auditory system, five behaviors in noise exist within a continuum, from neurons with high-fidelity representations of the signal, mostly found in IC and thalamus, to neurons with high-fidelity representations of the noise, mostly found in CN for the stationary noise and in similar proportions in each structure for the chorus noise. The two cortical areas displayed fewer robust responses than the IC and thalamus. Furthermore, between 21% and 72% of the neurons (depending on the structure) switch categories from one background noise to another, even if the initial assignment of these neurons to a category was confirmed by a severe bootstrap procedure. Importantly, supervised learning pointed out that assigning a recording to one of the five categories can be predicted up to a maximum of 70% based on both the response to signal alone and noise alone.
Collapse
|
6
|
Noise-Sensitive But More Precise Subcortical Representations Coexist with Robust Cortical Encoding of Natural Vocalizations. J Neurosci 2020; 40:5228-5246. [PMID: 32444386 DOI: 10.1523/jneurosci.2731-19.2020] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 05/08/2020] [Accepted: 05/15/2020] [Indexed: 01/30/2023] Open
Abstract
Humans and animals maintain accurate sound discrimination in the presence of loud sources of background noise. It is commonly assumed that this ability relies on the robustness of auditory cortex responses. However, only a few attempts have been made to characterize neural discrimination of communication sounds masked by noise at each stage of the auditory system and to quantify the noise effects on the neuronal discrimination in terms of alterations in amplitude modulations. Here, we measured neural discrimination between communication sounds masked by a vocalization-shaped stationary noise from multiunit responses recorded in the cochlear nucleus, inferior colliculus, auditory thalamus, and primary and secondary auditory cortex at several signal-to-noise ratios (SNRs) in anesthetized male or female guinea pigs. Masking noise decreased sound discrimination of neuronal populations in each auditory structure, but collicular and thalamic populations showed better performance than cortical populations at each SNR. In contrast, in each auditory structure, discrimination by neuronal populations was slightly decreased when tone-vocoded vocalizations were tested. These results shed new light on the specific contributions of subcortical structures to robust sound encoding, and suggest that the distortion of slow amplitude modulation cues conveyed by communication sounds is one of the factors constraining the neuronal discrimination in subcortical and cortical levels.SIGNIFICANCE STATEMENT Dissecting how auditory neurons discriminate communication sounds in noise is a major goal in auditory neuroscience. Robust sound coding in noise is often viewed as a specific property of cortical networks, although this remains to be demonstrated. Here, we tested the discrimination performance of neuronal populations at five levels of the auditory system in response to conspecific vocalizations masked by noise. In each acoustic condition, subcortical neurons better discriminated target vocalizations than cortical ones and in each structure, the reduction in discrimination performance was related to the reduction in slow amplitude modulation cues.
Collapse
|
7
|
The time course of auditory recognition measured with rapid sequences of short natural sounds. Sci Rep 2019; 9:8005. [PMID: 31142750 PMCID: PMC6541711 DOI: 10.1038/s41598-019-43126-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Accepted: 03/25/2019] [Indexed: 11/09/2022] Open
Abstract
Human listeners are able to recognize accurately an impressive range of complex sounds, such as musical instruments or voices. The underlying mechanisms are still poorly understood. Here, we aimed to characterize the processing time needed to recognize a natural sound. To do so, by analogy with the “rapid visual sequential presentation paradigm”, we embedded short target sounds within rapid sequences of distractor sounds. The core hypothesis is that any correct report of the target implies that sufficient processing for recognition had been completed before the time of occurrence of the subsequent distractor sound. We conducted four behavioral experiments using short natural sounds (voices and instruments) as targets or distractors. We report the effects on performance, as measured by the fastest presentation rate for recognition, of sound duration, number of sounds in a sequence, the relative pitch between target and distractors and target position in the sequence. Results showed a very rapid auditory recognition of natural sounds in all cases. Targets could be recognized at rates up to 30 sounds per second. In addition, the best performance was observed for voices in sequences of instruments. These results give new insights about the remarkable efficiency of timbre processing in humans, using an original behavioral paradigm to provide strong constraints on future neural models of sound recognition.
Collapse
|
8
|
Occelli F, Hasselmann F, Bourien J, Eybalin M, Puel J, Desvignes N, Wiszniowski B, Edeline JM, Gourévitch B. Age-related Changes in Auditory Cortex Without Detectable Peripheral Alterations: A Multi-level Study in Sprague–Dawley Rats. Neuroscience 2019; 404:184-204. [DOI: 10.1016/j.neuroscience.2019.02.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Revised: 01/21/2019] [Accepted: 02/01/2019] [Indexed: 01/31/2023]
|
9
|
Oster MM, Werner LA. Infants use onset asynchrony cues in auditory scene analysis. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:2052. [PMID: 30404496 PMCID: PMC6181648 DOI: 10.1121/1.5058397] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 09/01/2018] [Accepted: 09/17/2018] [Indexed: 06/08/2023]
Abstract
This experiment investigated the effect of onset asynchrony on the segregation of concurrent vowels in infants and adults. Two vowels, randomly chosen from seven American-English vowels, were superimposed. Each vowel pair contained one vowel by a male and one by a female talker. A train of such vowel pairs was presented to listeners, who were trained to respond to the male target vowel /i:/ or /u:/. The ability to identify the target vowel was compared among three conditions: synchronous onset, 100-, and 200-ms onset asynchrony. Experiment 1 measured performance, in d', in 7-month-old infants and adults. Infants and adults performed better with asynchronous than synchronous vowel onset, regardless of asynchrony duration. Experiment 2 compared the proportion of 3-month-old infants achieving an 80% correct criterion with and without onset asynchrony. Significantly more infants reached criterion with asynchronous than with synchronous vowel onset. Asynchrony duration did not influence performance. These experiments show that infants, as young as 3 months old, benefit from onset asynchrony.
Collapse
Affiliation(s)
- Monika-Maria Oster
- Department of Speech and Hearing Sciences, University of Washington, 1417 Northeast 42nd Street, Seattle, Washington 98105, USA
| | - Lynne A Werner
- Department of Speech and Hearing Sciences, University of Washington, 1417 Northeast 42nd Street, Seattle, Washington 98105, USA
| |
Collapse
|
10
|
Adenis V, Gourévitch B, Mamelle E, Recugnat M, Stahl P, Gnansia D, Nguyen Y, Edeline JM. ECAP growth function to increasing pulse amplitude or pulse duration demonstrates large inter-animal variability that is reflected in auditory cortex of the guinea pig. PLoS One 2018; 13:e0201771. [PMID: 30071005 PMCID: PMC6072127 DOI: 10.1371/journal.pone.0201771] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2018] [Accepted: 07/21/2018] [Indexed: 12/20/2022] Open
Abstract
Despite remarkable advances made to ameliorate how cochlear implants process the acoustic environment, many improvements can still be made. One of most fundamental questions concerns a strategy to simulate an increase in sound intensity. Psychoacoustic studies indicated that acting on either the current, or the duration of the stimulating pulses leads to perception of changes in how loud the sound is. The present study compared the growth function of electrically evoked Compound Action Potentials (eCAP) of the 8th nerve using these two strategies to increase electrical charges (and potentially to increase the sound intensity). Both with chronically (experiment 1) or acutely (experiment 2) implanted guinea pigs, only a few differences were observed between the mean eCAP amplitude growth functions obtained with the two strategies. However, both in chronic and acute experiments, many animals showed larger increases of eCAP amplitude with current increase, whereas some animals showed larger of eCAP amplitude with duration increase, and other animals show no difference between either approaches. This indicates that the parameters allowing the largest increase in eCAP amplitude considerably differ between subjects. In addition, there was a significant correlation between the strength of neuronal firing rate in auditory cortex and the effect of these two strategies on the eCAP amplitude. This suggests that pre-selecting only one strategy for recruiting auditory nerve fibers in a given subject might not be appropriate for all human subjects.
Collapse
Affiliation(s)
- Victor Adenis
- Paris-Saclay Institute of Neurosciences (Neuro-PSI) Université Paris-Sud, Orsay, France
- CNRS UMR 9197, Orsay, France
- Université Paris-Saclay, Orsay, France
| | - Boris Gourévitch
- Paris-Saclay Institute of Neurosciences (Neuro-PSI) Université Paris-Sud, Orsay, France
- CNRS UMR 9197, Orsay, France
- Université Paris-Saclay, Orsay, France
| | | | | | | | | | - Yann Nguyen
- INSERM UMR-S-1159, Paris, France
- Université Paris-VI, Paris, France
| | - Jean-Marc Edeline
- Paris-Saclay Institute of Neurosciences (Neuro-PSI) Université Paris-Sud, Orsay, France
- CNRS UMR 9197, Orsay, France
- Université Paris-Saclay, Orsay, France
- * E-mail:
| |
Collapse
|
11
|
Aushana Y, Souffi S, Edeline JM, Lorenzi C, Huetz C. Robust Neuronal Discrimination in Primary Auditory Cortex Despite Degradations of Spectro-temporal Acoustic Details: Comparison Between Guinea Pigs with Normal Hearing and Mild Age-Related Hearing Loss. J Assoc Res Otolaryngol 2018; 19:163-180. [PMID: 29302822 PMCID: PMC5878150 DOI: 10.1007/s10162-017-0649-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2017] [Accepted: 12/11/2017] [Indexed: 01/04/2023] Open
Abstract
This study investigated to which extent the primary auditory cortex of young normal-hearing and mild hearing-impaired aged animals is able to maintain invariant representation of critical temporal-modulation features when sounds are submitted to degradations of fine spectro-temporal acoustic details. This was achieved by recording ensemble of cortical responses to conspecific vocalizations in guinea pigs with either normal hearing or mild age-related sensorineural hearing loss. The vocalizations were degraded using a tone vocoder. The neuronal responses and their discrimination capacities (estimated by mutual information) were analyzed at single recording and population levels. For normal-hearing animals, the neuronal responses decreased as a function of the number of the vocoder frequency bands, so did their discriminative capacities at the single recording level. However, small neuronal populations were found to be robust to the degradations induced by the vocoder. Similar robustness was obtained when broadband noise was added to exacerbate further the spectro-temporal distortions produced by the vocoder. A comparable pattern of robustness to degradations in fine spectro-temporal details was found for hearing-impaired animals. However, the latter showed an overall decrease in neuronal discrimination capacities between vocalizations in noisy conditions. Consistent with previous studies, these results demonstrate that the primary auditory cortex maintains robust neural representation of temporal envelope features for communication sounds under a large range of spectro-temporal degradations.
Collapse
Affiliation(s)
- Yonane Aushana
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Orsay, France
- Université Paris-Sud, 91405 Orsay cedex, France
- Université Paris-Saclay, 91405 Orsay cedex, France
| | - Samira Souffi
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Orsay, France
- Université Paris-Sud, 91405 Orsay cedex, France
- Université Paris-Saclay, 91405 Orsay cedex, France
| | - Jean-Marc Edeline
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Orsay, France
- Université Paris-Sud, 91405 Orsay cedex, France
- Université Paris-Saclay, 91405 Orsay cedex, France
| | - Christian Lorenzi
- Laboratoire des Systèmes Perceptifs, UMR CNRS 8248, Département d’Etudes Cognitives, Ecole Normale Supérieure (ENS), Paris Sciences & Lettres Research University, 75005 Paris, France
| | - Chloé Huetz
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Orsay, France
- Université Paris-Sud, 91405 Orsay cedex, France
- Université Paris-Saclay, 91405 Orsay cedex, France
| |
Collapse
|
12
|
Sun W, Barbour DL. Rate, not selectivity, determines neuronal population coding accuracy in auditory cortex. PLoS Biol 2017; 15:e2002459. [PMID: 29091725 PMCID: PMC5683657 DOI: 10.1371/journal.pbio.2002459] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 11/13/2017] [Accepted: 10/11/2017] [Indexed: 11/18/2022] Open
Abstract
The notion that neurons with higher selectivity carry more information about external sensory inputs is widely accepted in neuroscience. High-selectivity neurons respond to a narrow range of sensory inputs, and thus would be considered highly informative by rejecting a large proportion of possible inputs. In auditory cortex, neuronal responses are less selective immediately after the onset of a sound and then become highly selective in the following sustained response epoch. These 2 temporal response epochs have thus been interpreted to encode first the presence and then the content of a sound input. Contrary to predictions from that prevailing theory, however, we found that the neural population conveys similar information about sound input across the 2 epochs in spite of the neuronal selectivity differences. The amount of information encoded turns out to be almost completely dependent upon the total number of population spikes in the read-out window for this system. Moreover, inhomogeneous Poisson spiking behavior is sufficient to account for this property. These results imply a novel principle of sensory encoding that is potentially shared widely among multiple sensory systems.
Collapse
Affiliation(s)
- Wensheng Sun
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri, United States of America
| | - Dennis L. Barbour
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri, United States of America
- * E-mail:
| |
Collapse
|