1
|
Assante R, Zampella E, Cantoni V, Green R, D'Antonio A, Mannarino T, Gaudieri V, Nappi C, Buongiorno P, Panico M, Petretta M, Cuocolo A, Acampa W. Prognostic value of myocardial perfusion imaging by cadmium zinc telluride single-photon emission computed tomography in patients with suspected or known coronary artery disease: a systematic review and meta-analysis. Eur J Nucl Med Mol Imaging 2023; 50:3647-3658. [PMID: 37480369 PMCID: PMC10547640 DOI: 10.1007/s00259-023-06344-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 07/13/2023] [Indexed: 07/24/2023]
Abstract
BACKGROUND Aim of this study was to define the prognostic value of stress myocardial perfusion imaging by cadmium zinc telluride (CZT) single-photon emission computed tomography (SPECT) for prediction of adverse cardiovascular events in patients with known or suspected coronary artery disease (CAD). METHODS AND RESULTS Studies published until November 2022 were identified by database search. We included studies using stress myocardial perfusion imaging by CZT-SPECT to evaluate subjects with known or suspected CAD and providing primary data of adverse cardiovascular events. Total of 12 studies were finally included recruiting 36,415 patients. Pooled hazard ratio (HR) for the occurrence of adverse events was 2.17 (95% confidence interval, CI, 1.78-2.65) and heterogeneity was 66.1% (P = 0.001). Five studies reported data on adjusted HR for the occurrence of adverse events. Pooled HR was 1.69 (95% CI, 1.44-1.98) and heterogeneity was 44.9% (P = 0.123). Seven studies reported data on unadjusted HR for the occurrence of adverse events. Pooled HR was 2.72 (95% CI, 2.00-3.70). Nine studies reported data useful to calculate separately the incidence rate of adverse events in patients with abnormal and normal myocardial perfusion. Pooled incidence rate ratio was 2.38 (95% CI, 1.39-4.06) and heterogeneity was 84.6% (P < 0.001). The funnel plot showed no evidence of asymmetry (P = 0.517). At meta-regression analysis, we found an association between HR for adverse events and presence of angina symptoms and family history of CAD. CONCLUSIONS Stress myocardial perfusion imaging by CZT-SPECT is a valuable noninvasive prognostic indicator for adverse cardiovascular events in patients with known or suspected CAD.
Collapse
Affiliation(s)
- Roberta Assante
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Emilia Zampella
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Valeria Cantoni
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Roberta Green
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Adriana D'Antonio
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Teresa Mannarino
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Valeria Gaudieri
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Carmela Nappi
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Pietro Buongiorno
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Mariarosaria Panico
- Institute of Biostructure and Bioimaging, National Council of Research, Naples, Italy
| | | | - Alberto Cuocolo
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Wanda Acampa
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy.
| |
Collapse
|
2
|
Liu L, Dai N, Yin G, Zhang W, Mohammed AQ, Xu S, Lv X, Shi T, Feng C, Mohammed AA, Mareai RM, Xu Y, Yu X, Abdu FA, Yu F, Che W. Prognostic value of combined coronary angiography-derived IMR and myocardial perfusion imaging by CZT SPECT in INOCA. J Nucl Cardiol 2023; 30:684-701. [PMID: 35918592 DOI: 10.1007/s12350-022-03038-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 05/26/2022] [Indexed: 10/16/2022]
Abstract
BACKGROUND A significant proportion of ischemia with non-obstructive coronary artery disease (INOCA) demonstrate coronary microvascular dysfunction (CMD), a condition associated with abnormal myocardial perfusion imaging (MPI) and adverse outcomes. Coronary angiography-derived index of microvascular resistance (caIMR) is a novel non-invasive technique to assess CMD. We aimed to investigate the prognostic value of combined caIMR and MPI by CZT SPECT in INOCA patients. METHODS Consecutive 151 patients with chest pain and < 50% coronary stenosis who underwent coronary angiography and MPI within 3 months were enrolled. caIMR was calculated by computational pressure-flow dynamics. CMD was defined as caIMR ≥ 25. The endpoint was major adverse cardiac events (MACE: cardiovascular death, nonfatal myocardial infarction, revascularization, angina-related rehospitalization, heart failure, and stroke). RESULTS Of all INOCA patients, CMD was present in 93 (61.6%) patients. The prevalence of abnormal MPI was significantly higher in CMD compared with non-CMD patients (40.9% vs 13.8%, P < .001). CMD showed a higher risk of MACE than non-CMD patients. Patients with both CMD and abnormal MPI had the worst prognosis, followed by patients with CMD and normal MPI (log-rank P < .001). Cox regression analysis identified CMD (HR 3.121, 95%CI 1.221-7.974, P = .017) and MPI (HR 2.704, 95%CI 1.030-7.099, P = .043) as predictive of MACE. The prognostic value of INOCA patients enhanced significantly by adding CMD and MPI to the model with clinical risk factors (AUC = 0.777 vs 0.686, P = .030). CONCLUSION caIMR-derived CMD is associated with increased risk of MACE among INOCA patients. Patients with abnormalities on both caIMR and MPI had the worse outcomes.
Collapse
Affiliation(s)
- Lu Liu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Neng Dai
- Department of Cardiology, Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Guoqing Yin
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Wen Zhang
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Abdul-Quddus Mohammed
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Siling Xu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Xian Lv
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Tingting Shi
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Cailin Feng
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Ayman A Mohammed
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Redhwan M Mareai
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Yawei Xu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Xuejing Yu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China.
| | - Fuad A Abdu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China.
| | - Fei Yu
- Department of Nuclear Medicine, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China.
| | - Wenliang Che
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China.
- Department of Cardiology, Shanghai Tenth People's Hospital Chongming Branch, Tongji University School of Medicine, Shanghai, China.
| |
Collapse
|
3
|
Henzlova MJ, Duvall L. Is the CZT technology the future of nuclear cardiology? J Nucl Cardiol 2022; 29:737-740. [PMID: 33128127 DOI: 10.1007/s12350-020-02399-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Accepted: 09/04/2020] [Indexed: 10/23/2022]
|
4
|
Liu L, Abdu FA, Yin G, Xu B, Mohammed AQ, Xu S, Lv X, Luo Y, Zu L, Yang C, Zhang Z, Zhou Y, Cai H, Lv Z, Xu Y, Che W. Prognostic value of myocardial perfusion imaging with D-SPECT camera in patients with ischemia and no obstructive coronary artery disease (INOCA). J Nucl Cardiol 2021; 28:3025-3037. [PMID: 33000403 DOI: 10.1007/s12350-020-02252-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2019] [Accepted: 06/01/2020] [Indexed: 12/21/2022]
Abstract
BACKGROUND Myocardial perfusion imaging (MPI) with a novel D-SPECT camera maintains excellent prognostic value compared to conventional SPECT. However, information about the relationship between D-SPECT MPI and the prognosis in patients with ischemia and no obstructive coronary artery disease (INOCA) is limited. The objective of this study was to evaluate the prognostic value of MPI with D-SPECT in INOCA and obstructive coronary artery disease (CAD) patients. METHODS All consecutive patients with suspected CAD and without prior CAD who underwent D-SPECT MPI and invasive coronary angiography within 3 months were considered. INOCA and obstructive CAD were defined as < 50% and ≥ 50% coronary stenosis, respectively. Patients were followed-up for the occurrence of major adverse cardiac events (MACE: cardiovascular death, nonfatal myocardial infarction, revascularization, stroke, heart failure and angina-related rehospitalization). RESULTS Among 506 patients, 232 (45.8%) were INOCA patients. A total of 33.2% of the INOCA patients had abnormal D-SPECT MPI, whereas 77.7% of the obstructive CAD patients had abnormal D-SPECT MPI. In both groups, patients with abnormal D-SPECT MPI demonstrated higher MACE rates and lower survival free of MACE. In addition, patients with INOCA and abnormal D-SPECT MPI had a poor prognosis similar to that of the obstructive CAD patients. Cox regression analysis showed that the risk-adjusted hazard ratios for abnormal D-SPECT MPI were 2.55 [1.11-5.87] and 2.06 [1.03-4.10] in the INOCA and obstructive CAD patients, respectively. CONCLUSIONS D-SPECT MPI provides excellent prognostic information, with a more severe prognosis in patients with abnormal D-SPECT MPI. INOCA patients with abnormal D-SPECT MPI experience a poor prognosis similar to that of patients with obstructive CAD.
Collapse
Affiliation(s)
- Lu Liu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
- Department of Cardiology, Clinical Medical College of Shanghai Tenth People's Hospital, Nanjing Medical University, Shanghai, China
| | - Fuad A Abdu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Guoqing Yin
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
- Department of Cardiology, Clinical Medical College of Shanghai Tenth People's Hospital, Nanjing Medical University, Shanghai, China
| | - Bin Xu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Abdul-Quddus Mohammed
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Siling Xu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Xian Lv
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Yanru Luo
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Lu Zu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Changrui Yang
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Ziyi Zhang
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Yuxiao Zhou
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Haidong Cai
- Department of Nuclear Medicine, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Zhongwei Lv
- Department of Nuclear Medicine, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China.
| | - Yawei Xu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China.
| | - Wenliang Che
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China.
| |
Collapse
|
5
|
Assante R, Zampella E, Acampa W. Advanced technology in the risk stratification-based strategy: The way forward to keep going. J Nucl Cardiol 2021; 28:2937-2940. [PMID: 32533425 DOI: 10.1007/s12350-020-02198-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Accepted: 05/08/2020] [Indexed: 10/24/2022]
Affiliation(s)
- Roberta Assante
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Emilia Zampella
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Wanda Acampa
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy.
- Institute of Biostructure and Bioimaging, National Council of Research, Naples, Italy.
| |
Collapse
|
6
|
Cantoni V, Green R, Acampa W, Zampella E, Assante R, Nappi C, Gaudieri V, Mannarino T, Cuocolo R, Di Vaia E, Petretta M, Cuocolo A. Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis. J Nucl Cardiol 2021; 28:698-715. [PMID: 31089962 DOI: 10.1007/s12350-019-01747-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Accepted: 04/23/2019] [Indexed: 12/21/2022]
Abstract
BACKGROUND We performed a meta-analysis to compare the diagnostic performance of conventional SPECT (C-SPECT) and cadmium-zinc-telluride (CZT)-SPECT systems in detecting angiographically proven coronary artery disease (CAD). METHODS Studies published between January 2000 and February 2018 were identified by database search. We included studies assessing C-SPECT or CZT-SPECT as a diagnostic test to evaluate patients for the presence of CAD, defined as at least 50% diameter stenosis on invasive coronary angiography. A study was eligible regardless of whether patients were referred for suspected or known CAD. RESULTS We identified 40 eligible articles (25 C-SPECT and 15 CZT-SPECT studies) including 7334 patients (4997 in C-SPECT and 2337 in CZT-SPECT studies). The pooled sensitivity and specificity were 85% and 66% for C-SPECT and 89% and 69% for CZT-SPECT imaging studies. The area under the curve was slightly higher for CZT-SPECT (0.89) compared to C-SPECT (0.83); accordingly, the summary diagnostic OR was 17 for CZT-SPECT and 11 for C-SPECT. The accuracy of the two tests slightly differs between C-SPECT and CZT-SPECT (chi-square 11.28, P < .05). At meta-regression analysis, no significant association between both sensitivity and specificity and demographical and clinical variables considered was found for C-SPECT and CZT-SPECT studies. CONCLUSIONS C-SPECT and CZT-SPECT have good diagnostic performance in detecting angiographic proven CAD, with a slightly higher accuracy for CZT-SPECT. This result supports the use of the novel gamma cameras in clinical routine practices also considering the improvements in acquisition time and radiation exposure reduction.
Collapse
Affiliation(s)
- Valeria Cantoni
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Roberta Green
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Wanda Acampa
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
- Institute of Biostructure and Bioimaging, National Council of Research, Naples, Italy
| | - Emilia Zampella
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Roberta Assante
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Carmela Nappi
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Valeria Gaudieri
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Teresa Mannarino
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Renato Cuocolo
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Eugenio Di Vaia
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Mario Petretta
- Department of Translational Medical Sciences, University Federico II, Naples, Italy
| | - Alberto Cuocolo
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy.
| |
Collapse
|
7
|
Yamada Y, Nakano S, Gatate Y, Okano N, Muramatsu T, Nishimura S, Kuji I, Fukushima K, Matsunari I. Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction. J Nucl Cardiol 2021; 28:187-195. [PMID: 30603890 DOI: 10.1007/s12350-018-01585-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 12/17/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND Simultaneous dual-tracer imaging using isotopes with close photo-peaks may benefit from improved properties of cadmium-zinc-telluride (CZT)-based scanners. METHODS Thirty patients having undergone primary percutaneous coronary intervention for acute myocardial infarction underwent single-(99mTc-tetrofosmin (TF) or 123I-BMIPP first) followed by simultaneous 99mTc-TF /123I-BMIPP dual-tracer imaging using a Discovery NM/CT 670 CZT. The values for the quantitative gated-SPECT (QGS) and the quantitative perfusion SPECT (QPS) were assessed. RESULTS The intra-class correlation (ICC) coefficients between the single- and dual-tracer imaging were high in all the QGS and QPS data (Summed motion score: 0.95, summed thickening score: 0.94, ejection fraction: 0.98, SRS for 99mTc-TF: 0.97/ for 123I-BMIPP: 0.95). Wall motion, wall thickening and rest scores per coronary-territory-based regions were also comparable between the single- and dual imaging (ICC coefficient > 0.91). The interrater concordance in the visual analysis for the infarction and perfusion-metabolism mismatch was significant for the global and regional left ventricle (P < 0.001). CONCLUSION The quantitative/semi-quantitative values for global and regional left-ventricular function, perfusion, and fatty acid metabolism were closely comparable between the dual-tracer imaging and the single-tracer mode. These data suggests the feasibility of the novel CZT-based scanner for the simultaneous 99mTc-TF /123I-BMIPP dual-tracer acquisitions in clinical settings.
Collapse
Affiliation(s)
- Yoshihiro Yamada
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Shintaro Nakano
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan.
| | - Youdou Gatate
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Nanami Okano
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University, Saitama, Japan
| | - Toshihiro Muramatsu
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Shigeyuki Nishimura
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Ichiei Kuji
- Department of Nuclear Medicine International Medical Center, Saitama Medical University, Saitama, Japan
| | - Kenji Fukushima
- Department of Nuclear Medicine International Medical Center, Saitama Medical University, Saitama, Japan
| | - Ichiro Matsunari
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University, Saitama, Japan
| |
Collapse
|
8
|
Nappi C, Gaudieri V, Petretta M. Simultaneous dual-tracer 99mTc-tetrofosmin and 123I-BMIPP acquisition with CZT for ischemic memory: The future approaches to image the past. J Nucl Cardiol 2021; 28:196-198. [PMID: 30701444 DOI: 10.1007/s12350-019-01614-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Accepted: 01/16/2019] [Indexed: 12/01/2022]
Affiliation(s)
- Carmela Nappi
- Department of Advanced Biomedical Sciences, University Federico II, Naples, Italy
| | - Valeria Gaudieri
- Department of Advanced Biomedical Sciences, University Federico II, Naples, Italy
| | - Mario Petretta
- Department of Translational Medical Sciences, University Federico II, Naples, Italy.
| |
Collapse
|
9
|
Gimelli A, Pugliese NR, Buechel RR, Coceani M, Clemente A, Kaufmann PA, Marzullo P. Myocardial perfusion scintigraphy for risk stratification of patients with coronary artery disease: the AMICO registry. Eur Heart J Cardiovasc Imaging 2020; 23:372-380. [PMID: 33247905 DOI: 10.1093/ehjci/jeaa298] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2020] [Accepted: 10/13/2020] [Indexed: 01/20/2023] Open
Abstract
AIMS We assessed the prognostic value of myocardial perfusion scintigraphy (MPS) with cadmium-zinc-telluride in addition to clinical and coronary anatomy analysis. METHODS AND RESULTS We prospectively enrolled 1464 patients (26% females, 69.5 ± 10.4 years) referred for stress-rest MPS. All the patients underwent invasive coronary angiography (1171, 80%) or coronary computed tomography angiography (293, 20%). We defined a composite endpoint of cardiovascular death and non-fatal MI. After an 8-year follow-up, summed stress score (SSS) had the highest accuracy in predicting primary endpoint with a ROC-derived cut-off of SSS >8 (>10% myocardium). SSS >8 portended the lowest survival probability at Kaplan-Meier analysis (P < 0.0001 for the composite endpoint and individual components). The Cox-regression analysis indicated SSS as an independent predictor of the composite endpoint, along with fasting blood glucose and total cholesterol and contrary to coronary anatomy parameters. Patients with SSS >8 treated with optimal medical therapy (OMT) had the largest area of necrosis, the lower ischaemic burden, the most compromised LV systo-diastolic function and the highest LV mass, but received a less aggressive treatment in comparison to early revascularized patients. Survival analysis revealed patients with SSS ≤8 had the greater freedom from events, irrespective of the treatment strategy, while the group with SSS >8 and OMT had the worst outcome, followed by patients with SSS >8 and early revascularization (log-rank test: all P < 0.0001). CONCLUSION MPS-SSS constitutes a strong independent predictor of future adverse events after adjustment for multiple clinical parameters and coronary angiography. In particular, MPS could help risk stratification of patients who did not undergo early revascularization.
Collapse
Affiliation(s)
- Alessia Gimelli
- Fondazione Toscana Gabriele Monasterio, Department of Nuclear Medicine, via Moruzzi n.1 - 56124 - Pisa, Italy
| | - Nicola Riccardo Pugliese
- Department of Clinical and Experimental Medicine, University of Pisa, Via Roma, 67 56126 Pisa, Italy
| | - Ronny R Buechel
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland
| | - Michele Coceani
- Fondazione Toscana Gabriele Monasterio, Department of Nuclear Medicine, via Moruzzi n.1 - 56124 - Pisa, Italy
| | - Alberto Clemente
- Fondazione Toscana Gabriele Monasterio, Department of Nuclear Medicine, via Moruzzi n.1 - 56124 - Pisa, Italy
| | - Philipp A Kaufmann
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland
| | - Paolo Marzullo
- Fondazione Toscana Gabriele Monasterio, Department of Nuclear Medicine, via Moruzzi n.1 - 56124 - Pisa, Italy.,CNR, Institute of Clinical Physiology, via Moruzzi n.1 - 56124 - Pisa, Italy
| |
Collapse
|
10
|
Piekarski E, Manrique A, Rouzet F, Le Guludec D. Current Status of Myocardial Perfusion Imaging With New SPECT/CT Cameras. Semin Nucl Med 2020; 50:219-226. [PMID: 32284108 DOI: 10.1053/j.semnuclmed.2020.02.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Myocardial perfusion imaging (MPI) with Single-Photon Emission Computed Tomography (SPECT) has a major role in the management of coronary artery disease. Recent technological advances regarding SPECT detectors with the use of solid-state detectors has allowed for improved imaging quality since a decade with dramatic dose and/or time reduction of imaging protocols due to improved sensitivity and spatial resolution, and is now performed as a routine exam. Interestingly, this new technology has modified our everyday practice, from acquisition protocols (low dose and ultra-fast protocols) to image semiology. Numerous studies have shown how these technical advances have allowed for improved patient management, with similar or improved diagnostic and prognostic information derived from MPI. These improvements have also led to the straightforward implementation of myocardial blood flow measurement. This article reviews the current status of MPI using new SPECT and SPECT/CT cameras.
Collapse
Affiliation(s)
- Eve Piekarski
- Nuclear Medicine Department, Bichat Hospital, AP-HP, Paris, France; Université de Paris, Paris, France; Laboratory for Vascular Translational Science, INSERM, Paris, France
| | - Alain Manrique
- Normandie Univ, UNICAEN, Caen, France; Médecine Nucléaire, CHU de Caen, Caen, France; GIP Cyceron, Campus Jules Horowitz, Caen, France
| | - François Rouzet
- Nuclear Medicine Department, Bichat Hospital, AP-HP, Paris, France; Université de Paris, Paris, France; Laboratory for Vascular Translational Science, INSERM, Paris, France
| | - Dominique Le Guludec
- Nuclear Medicine Department, Bichat Hospital, AP-HP, Paris, France; Université de Paris, Paris, France; Laboratory for Vascular Translational Science, INSERM, Paris, France.
| |
Collapse
|
11
|
Shortened acquisition time in simultaneous 99mTc-tetrofosmin and 123I-β-methyl-p-iodophenyl pentadecanoic acid dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction. Nucl Med Commun 2020; 40:1130-1137. [PMID: 31524763 DOI: 10.1097/mnm.0000000000001084] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The use of cadmium-zinc-telluride-based scanners may increase the clinical feasibility of simultaneous dual-isotope imaging. In the current study, we sought to investigate a potential acquisition time in simultaneous Tc-tetrofosmin/I-β-methyl-p-iodophenyl pentadecanoic acid dual-isotope imaging using a Discovery NM/CT 670 cadmium-zinc-telluride. METHODS Simultaneous Tc-tetrofosmin/I-β-methyl-p-iodophenyl pentadecanoic acid dual-isotope imaging was performed in 29 patients who had undergone primary percutaneous coronary intervention for acute myocardial infarction. Referenced images with an acquisition time of 65 s/view (16.25 min) were reframed to produce images with acquisition times of 33, 16, and 8 s/view. The values for the quantitative-gated single-photon emission computed tomography (SPECT) and the quantitative perfusion SPECT were compared. RESULTS The quantitative-gated SPECT values for images with 33, 16, and 8 s/views showed good consistency with those for 65 s/view (the lower 95% confidence intervals for the intraclass correlation were ≥0.80). The quantitative perfusion SPECT values for Tc-tetrofosmin images with 33, 16, and 8 s/views also showed good consistency with those for 65 s/view; however, the quantitative perfusion SPECT values for I-β-methyl-p-iodophenyl pentadecanoic acid images with an acquisition time of 8 s/view were not consistent with the reference acquisition time of 65 s/view. CONCLUSIONS The quantitative-gated SPECT and quantitative perfusion SPECT values obtained from images with shorter acquisition times correlated with the values obtained from images with a reference acquisition time of 65 s/view; however, tracer-specific predisposition should be considered. These findings suggest that it is possible to reduce acquisition time when performing simultaneous Tc-tetrofosmin/I-β-methyl-p-iodophenyl pentadecanoic acid dual-tracer imaging with the novel cadmium-zinc-telluride scanner.
Collapse
|
12
|
Slomka PJ, Miller RJ, Hu LH, Germano G, Berman DS. Solid-State Detector SPECT Myocardial Perfusion Imaging. J Nucl Med 2019; 60:1194-1204. [DOI: 10.2967/jnumed.118.220657] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Accepted: 06/18/2019] [Indexed: 02/07/2023] Open
|
13
|
Hyafil F, Gimelli A, Slart RHJA, Georgoulias P, Rischpler C, Lubberink M, Sciagra R, Bucerius J, Agostini D, Verberne HJ. EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras. Eur J Hybrid Imaging 2019; 3:11. [PMID: 34191169 PMCID: PMC8218102 DOI: 10.1186/s41824-019-0058-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 06/10/2019] [Indexed: 01/28/2023] Open
Abstract
An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Discovery NM/CT 570c; General Electric Medical Systems), and the IQ-SPECT (Siemens Healthcare). The increased myocardial count sensitivity of these three cardiac-centered systems has allowed for a decrease in the activities of radiopharmaceuticals injected to patients for myocardial perfusion imaging and, consequently, radiation exposure of patients. When setting up protocols for MPS, the overall objective should be to maintain high diagnostic accuracy of MPS, while injecting the lowest activities reasonably achievable to reduce the level of radiation exposure of patient and staff. These guidelines aim at providing recommendations for acquisition protocols and image interpretation using cardiac-centered cameras. As each imaging system has specific design and features for image acquisition and analysis, these guidelines have been separated into three sections for each gamma camera system. These recommendations have been written by the members of the Cardiovascular Committee of EANM and were based on their own experience with each of these systems and on the existing literature.
Collapse
Affiliation(s)
- Fabien Hyafil
- Department of Nuclear Medicine; Bichat University Hospital, Assistance Publique - Hôpitaux de Paris; Inserm UMR 1148, Paris Diderot-Paris 7 University, 46 rue Henri Huchard, 75018, Paris, France.
| | | | - Riemer H J A Slart
- Medical Imaging Center, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, The Netherlands
- TechMed Centre, Department of Biomedical Photonic Imaging, University of Twente, Enschede, The Netherlands
| | - Panagiotis Georgoulias
- Department of Nuclear Medicine, University of Thessaly, University Hospital of Larissa, Larissa, Greece
| | - Christoph Rischpler
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Mark Lubberink
- Department of Medical Physics and PET Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Roberto Sciagra
- Nuclear Medicine Unit, Department of Experimental and Clinical Biomedical Sciences, University of Florence, Florence, Italy
| | - Jan Bucerius
- Department of Nuclear Medicine, Maastricht University Medical Center and Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
- Department of Nuclear Medicine, University Hospital RWTH Aachen, Aachen, Germany
| | - Denis Agostini
- Department of Nuclear Medicine, CHU Caen Normandy University, Caen, France
| | - Hein J Verberne
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
14
|
Zhang YQ, Jiang YF, Hong L, Chen M, Zhang NN, Yang HJ, Zhou YF. Diagnostic value of cadmium-zinc-telluride myocardial perfusion imaging versus coronary angiography in coronary artery disease: A PRISMA-compliant meta-analysis. Medicine (Baltimore) 2019; 98:e14716. [PMID: 30817614 PMCID: PMC6831125 DOI: 10.1097/md.0000000000014716] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND Rapid progress has been made in research of cadmium-zinc-telluride (CZT) technology in the last few years, which might serve as a new method to diagnose coronary artery disease. However, compared with coronary angiography, the diagnostic value of CZT is still controversial. We aimed to evaluate diagnosis value of coronary angiography versus CZT in coronary artery disease. METHODS We searched the database for eligible researches associated with CZT- myocardial perfusion imaging (MPI) and invasive coronary angiography, extracted the relevant data, and rigorously screened it according to the inclusion and exclusion criteria. The accuracy indicators included sensitivity, specificity, accuracy, positive and negative likelihood ratios. RESULTS According to the inclusion and exclusion criteria, we finally found 20 studies containing 2350 patients in this search. Pooled results showed that sensitivity of CZT-MPI was 0.84% and 95% confidence interval (95% CI): 0.78 to 0.89, specificity was 0.72, 95% CI (0.62-0.76), the specificity was lower apparently. The positive likelihood ratio was 3.0, 95% CI (2.4-3.8), the negative likelihood ratio was 0.22, 95% CI (0.16-0.31), diagnostic odds ratio was 14, 95% CI (7.84-17.42). CONCLUSION This meta-analysis showed that CZT-MPI had satisfactory sensitivity and specificity for diagnosing coronary artery disease. Larger studies are required for further evaluation.
Collapse
|
15
|
Okano N, Osawa I, Tsuchihashi S, Takahashi M, Niitsu M, Matsunari I. High-speed scanning of planar images showing 123I-MIBG uptake using a whole-body CZT camera: a phantom and clinical study. EJNMMI Res 2019; 9:22. [PMID: 30806836 PMCID: PMC6391509 DOI: 10.1186/s13550-019-0491-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2018] [Accepted: 02/11/2019] [Indexed: 11/10/2022] Open
Abstract
Background The heart-to-mediastinum ratio (HMR) obtained in myocardial sympathetic innervation imaging using 123I-metaiodobenzylguanidine (MIBG) is used for heart failure or Lewy body diseases (LBD). Discovery NM/CT 670 CZT, a novel whole-body scanner, enables direct HMR measurements in planar images, in contrast to cardiac-dedicated CZT-based cameras which require specific post-processing reconstruction. We sought to investigate the clinical utility of the Discovery NM/CT 670 CZT for myocardial innervation imaging and the potential time reduction. Results Following preliminary phantom examinations, 123I-MIBG planar imaging was performed in 36 patients with suspected or known LBD to measure HMRs with a collection time of 300 s. Images for different collection times were subsequently reframed using already acquired data, and changes in HMRs were evaluated. The HMRs for patients with versus without clinically diagnosed LBD were 1.63 ± 0.08 versus 2.21 ± 0.08 at early phase (p < 0.001) and 1.54 ± 0.09 versus 2.08 ± 0.09 at delayed phase (p < 0.001). The difference of HMRs (300 s − other collection time) became greater as the collection time became shorter. There was good consistency in HMRs between the 300-s images (reference) and the 200-s (intra-class correlation (ICC) coefficients > 0.99), 100-s (ICC coefficients > 0.97), and 50-s (ICC coefficients > 0.89) images. Conclusions In planar images with a whole-body CZT-based camera, the HMRs of patients with LBD were significantly lower than those without. HMRs with the collection time of 50 s and longer showed good consistency with those of 300 s in the ICC analysis. These findings indicate a clinical utility of this novel scanner for HMR measurements and potential time reductions. Electronic supplementary material The online version of this article (10.1186/s13550-019-0491-z) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Nanami Okano
- Department of Radiology, Saitama Medical University Hospital, 38 Morohongo, Moroyama, Iruma, Saitama, 350-0495, Japan.
| | - Iichiro Osawa
- Department of Radiology, Saitama Medical University Hospital, 38 Morohongo, Moroyama, Iruma, Saitama, 350-0495, Japan
| | - Saki Tsuchihashi
- Department of Radiology, Saitama Medical University Hospital, 38 Morohongo, Moroyama, Iruma, Saitama, 350-0495, Japan
| | - Masafumi Takahashi
- Department of Central Radiological Technology, Saitama Medical University Hospital, Saitama, Japan
| | - Mamoru Niitsu
- Department of Radiology, Saitama Medical University Hospital, 38 Morohongo, Moroyama, Iruma, Saitama, 350-0495, Japan
| | - Ichiro Matsunari
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University Hospital, Saitama, Japan
| |
Collapse
|
16
|
van Dijk JD, Borren NM, Mouden M, van Dalen JA, Ottervanger JP, Jager PL. Effect of a patient-specific minimum activity in stress myocardial perfusion imaging using CZT-SPECT: Prognostic value, radiation dose, and scan outcome. J Nucl Cardiol 2018; 25:26-35. [PMID: 28822102 DOI: 10.1007/s12350-017-1011-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Accepted: 05/31/2017] [Indexed: 10/19/2022]
Abstract
BACKGROUND SPECT Myocardial perfusion imaging (MPI) is associated with a relatively high radiation burden and decreasing image quality in heavy patients. Patient-specific low-activity protocols (PLAPs) are suggested but follow-up data is lacking. Our aim was to compare the use of a standard fixed-activity protocol (FAP) with a PLAP in cadmium zinc telluride (CZT)-SPECT MPI. METHODS We retrospectively included 1255 consecutive patients who underwent CZT-SPECT stress-optional rest MPI. 668 Patients were scanned using FAP (370 MBq) and 587 patients using PLAP (2.25 MBq·kg-1). Percentage of scans interpreted as normal, radiation dose, and 1-year follow-up including hard event rates (all-cause death or non-fatal myocardial infarction) were collected and compared. RESULTS The percentage of scans interpreted as normal was 67% in FAP and 70% in PLAP groups (P = .29). The annualized hard event rates in these patients were 1.0% in the FAP and 0.9% in the PLAP group (P = .86). However, the mean radiation dose decreased by 23% for stress-only and by 15% to 2.6 mSv for stress-optional rest MPI after introduction of the PLAP (p<0.001). CONCLUSIONS Introduction of a patient-specific low-activity protocol does not affect the percentage of scans interpreted as normal or prognosis but significantly lowers the radiation dose for CZT-SPECT MPI.
Collapse
Affiliation(s)
- J D van Dijk
- Department of Nuclear Medicine, Isala Hospital, PO Box 10400, 8000 GK, Zwolle, The Netherlands.
- MIRA: Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands.
| | - N M Borren
- Department of Cardiology, Isala Hospital, Zwolle, The Netherlands
| | - M Mouden
- Department of Cardiology, Isala Hospital, Zwolle, The Netherlands
| | - J A van Dalen
- Department of Medical Physics, Isala Hospital, Zwolle, The Netherlands
| | - J P Ottervanger
- Department of Cardiology, Isala Hospital, Zwolle, The Netherlands
| | - P L Jager
- Department of Nuclear Medicine, Isala Hospital, PO Box 10400, 8000 GK, Zwolle, The Netherlands
| |
Collapse
|
17
|
Taqueti VR, Dorbala S, Wolinsky D, Abbott B, Heller GV, Bateman TM, Mieres JH, Phillips LM, Wenger NK, Shaw LJ. Myocardial perfusion imaging in women for the evaluation of stable ischemic heart disease-state-of-the-evidence and clinical recommendations. J Nucl Cardiol 2017; 24:1402-1426. [PMID: 28585034 PMCID: PMC5942593 DOI: 10.1007/s12350-017-0926-8] [Citation(s) in RCA: 62] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Accepted: 05/15/2017] [Indexed: 12/21/2022]
Abstract
This document from the American Society of Nuclear Cardiology represents an updated consensus statement on the evidence base of stress myocardial perfusion imaging (MPI), emphasizing new developments in single-photon emission tomography (SPECT) and positron emission tomography (PET) in the clinical evaluation of women presenting with symptoms of stable ischemic heart disease (SIHD). The clinical evaluation of symptomatic women is challenging due to their varying clinical presentation, clinical risk factor burden, high degree of comorbidity, and increased risk of major ischemic heart disease events. Evidence is substantial that both SPECT and PET MPI effectively risk stratify women with SIHD. The addition of coronary flow reserve (CFR) with PET improves risk detection, including for women with nonobstructive coronary artery disease and coronary microvascular dysfunction. With the advent of PET with computed tomography (CT), multiparametric imaging approaches may enable integration of MPI and CFR with CT visualization of anatomical atherosclerotic plaque to uniquely identify at-risk women. Radiation dose-reduction strategies, including the use of ultra-low-dose protocols involving stress-only imaging, solid-state detector SPECT, and PET, should be uniformly applied whenever possible to all women undergoing MPI. Appropriate candidate selection for stress MPI and for post-MPI indications for guideline-directed medical therapy and/or invasive coronary angiography are discussed in this statement. The critical need for randomized and comparative trial data in female patients is also emphasized.
Collapse
Affiliation(s)
- Viviany R Taqueti
- Noninvasive Cardiovascular Imaging Program, Departments of Medicine and Radiology, Brigham and Women's Hospital, ASBI-L1 037-G, 75 Francis Street, Boston, MA, 02115, USA.
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| | - Sharmila Dorbala
- Noninvasive Cardiovascular Imaging Program, Departments of Medicine and Radiology, Brigham and Women's Hospital, ASBI-L1 037-G, 75 Francis Street, Boston, MA, 02115, USA
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - David Wolinsky
- Department of Cardiovascular Medicine, Cleveland Clinic Florida, Weston, FL, USA
| | - Brian Abbott
- Warren Alpert Medical School, Brown University, Providence, RI, USA
- Cardiovascular Institute, The Miriam and Newport Hospitals, Providence, RI, USA
| | - Gary V Heller
- Gagnon Cardiovascular Center, Morristown Medical Center, Morristown, NJ, USA
| | - Timothy M Bateman
- Saint Luke's Health System, University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | | | - Lawrence M Phillips
- Leon H. Charney Division of Cardiology, New York University Langone Medical Center, New York University School of Medicine, New York, NY, USA
| | - Nanette K Wenger
- Division of Cardiology, Department of Medicine, Emory University Clinical Cardiovascular Research Institute, Emory University School of Medicine, Atlanta, GA, USA
| | - Leslee J Shaw
- Division of Cardiology, Department of Medicine, Emory University Clinical Cardiovascular Research Institute, Emory University School of Medicine, Atlanta, GA, USA
| |
Collapse
|
18
|
Nudi F, Iskandrian AE, Schillaci O, Peruzzi M, Frati G, Biondi-Zoccai G. Diagnostic Accuracy of Myocardial Perfusion Imaging With CZT Technology: Systemic Review and Meta-Analysis of Comparison With Invasive Coronary Angiography. JACC Cardiovasc Imaging 2017; 10:787-794. [PMID: 28330657 DOI: 10.1016/j.jcmg.2016.10.023] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Revised: 09/29/2016] [Accepted: 10/05/2016] [Indexed: 02/08/2023]
Abstract
OBJECTIVES This study sought to summarize the evidence on stress myocardial perfusion imaging (MPI) using cadmium-zinc-telluride (CZT) technology for the diagnosis of obstructive coronary artery disease (CAD). The CZT cameras are newly introduced, and comparative data with the conventional Anger technology (Anger-MPI) are lacking. BACKGROUND The diagnostic accuracy of Anger-MPI for detection of angiographically significant CAD is well established; however, less evidence is available on the diagnostic accuracy of CZT-MPI. METHODS Clinical studies comparing CZT-MPI and invasive coronary angiography were systematically searched and abstracted. Calculations of diagnostic accuracy, including sensitivity, specificity, likelihood ratios, and diagnostic odds ratio, were obtained with fixed and random effects, reporting point estimates and 95% confidence intervals. RESULTS Based on our search, a total of 16 studies (N = 2,092) were included. The sensitivity of CZT-MPI was 0.84 (95% confidence interval [CI]: 0.78 to 0.89), whereas the specificity of 0.69 (95% CI: 0.62 to 0.76) was significantly reduced. The positive likelihood ratio was 2.73 (95% CI: 2.21 to 3.39), the negative likelihood ratio was 0.24 (95% CI: 0.17 to 0.31), and the diagnostic odds ratio was 11.93 (95% CI: 7.84 to 17.42). At subgroup and meta-regression analyses, the diagnostic accuracy between D-SPECT and Discovery cameras was similar (p = 0.711) and not impacted upon by smaller sample size studies (p = 0.573). CONCLUSIONS CZT-MPI has satisfactory sensitivity for angiographically significant CAD, but its suboptimal specificity warrants further development and research.
Collapse
Affiliation(s)
- Francesco Nudi
- Service of Hybrid Cardio Imaging, Madonna della Fiducia Clinic, Rome, Italy; Ostia Radiologica, Ostia, Italy; Etisan, Rome, Italy
| | - Ami E Iskandrian
- Division of Cardiovascular Disease, University of Alabama at Birmingham, Alabama
| | - Orazio Schillaci
- Department of Nuclear Medicine, Tor Vergata University, Rome, Italy
| | - Mariangela Peruzzi
- Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy
| | - Giacomo Frati
- Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy; Department of AngioCardioNeurology, IRCCS Neuromed, Pozzilli, Italy
| | - Giuseppe Biondi-Zoccai
- Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy; Department of AngioCardioNeurology, IRCCS Neuromed, Pozzilli, Italy.
| |
Collapse
|
19
|
Engbers EM, Timmer JR, Mouden M, Knollema S, Jager PL, Ottervanger JP. Prognostic Value of Myocardial Perfusion Imaging with a Cadmium-Zinc-Telluride SPECT Camera in Patients Suspected of Having Coronary Artery Disease. J Nucl Med 2017; 58:1459-1463. [PMID: 28450561 DOI: 10.2967/jnumed.116.188516] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Accepted: 02/28/2017] [Indexed: 12/21/2022] Open
Abstract
The prognostic value of myocardial perfusion imaging (MPI) with the cadmium-zinc-telluride (CZT) SPECT camera is not well established. Therefore, the aim of the current study was to evaluate the prognostic value of MPI performed with a CZT SPECT camera in a large cohort of patients suspected of having coronary artery disease. Methods: Consecutive symptomatic stable patients (n = 4,057) without a history of coronary artery disease underwent CZT SPECT MPI. During a median follow-up of 2.4 y (25th-75th percentile, 1.7-3.4), patients were monitored for primary (nonfatal myocardial infarction and cardiac mortality) and secondary outcomes (late revascularization [>90 d after scanning] and primary outcome). Results: Patients with normal perfusion demonstrated low annual event rates (primary outcome, 0.2%; secondary outcome, 0.6%). Annual event rates increased with the extent of abnormality of myocardial perfusion. In patients with small ischemic perfusion defects, annual event rates were 0.7% and 2.8% for the primary and secondary outcome, respectively. In patients with moderate or large ischemic perfusion defects, these event rates were 1.2% and 4.3%, respectively. After multivariate analysis, the risk for events was significantly associated with the extent of ischemia (hazard ratio for small ischemic defects: 2.2, 95% confidence interval [CI], 0.9-5.9 and 4.6, 95% CI, 2.8-7.6, for primary and secondary outcomes, respectively; hazard ratio for moderate or large ischemic defects: 4.0, 95% CI, 1.5-10.5 and 12.1, 95% CI, 7.2-20.2, for primary and secondary outcomes, respectively). Conclusion: Our findings show that MPI acquired with a CZT SPECT camera provides excellent prognostic information, with low event rates in patients with normal myocardial perfusion. In patients with abnormal SPECT MPI, the extent of abnormality is independently associated with an increased risk of events.
Collapse
Affiliation(s)
- Elsemiek M Engbers
- Department of Cardiology, Isala, Zwolle, The Netherlands; and .,Department of Nuclear Medicine, Isala, Zwolle, The Netherlands
| | - Jorik R Timmer
- Department of Cardiology, Isala, Zwolle, The Netherlands; and
| | - Mohamed Mouden
- Department of Cardiology, Isala, Zwolle, The Netherlands; and.,Department of Nuclear Medicine, Isala, Zwolle, The Netherlands
| | - Siert Knollema
- Department of Nuclear Medicine, Isala, Zwolle, The Netherlands
| | - Pieter L Jager
- Department of Nuclear Medicine, Isala, Zwolle, The Netherlands
| | | |
Collapse
|
20
|
van Dijk JD, Mouden M, Ottervanger JP, van Dalen JA, Knollema S, Slump CH, Jager PL. Value of attenuation correction in stress-only myocardial perfusion imaging using CZT-SPECT. J Nucl Cardiol 2017; 24:395-401. [PMID: 26780528 PMCID: PMC5413515 DOI: 10.1007/s12350-015-0374-2] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2015] [Revised: 11/30/2015] [Indexed: 11/05/2022]
Abstract
BACKGROUND Attenuation correction (AC) improves the diagnostic outcome of stress-only myocardial perfusion imaging (MPI) using conventional SPECT. Our aim was to determine the value of AC using a cadmium zinc telluride-based (CZT)-SPECT camera. METHODS AND RESULTS We retrospectively included 107 consecutive patients who underwent stress-optional rest MPI CZT-SPECT/CT. Next, we created three types of images for each patient; (1) only displaying reconstructed data without the CT-based AC (NC), (2) only displaying AC, and (3) with both NC and AC (NC + AC). Next, two experienced physicians visually interpreted these 321 randomized images as normal, equivocal, or abnormal. Image outcome was compared with all hard events over a mean follow-up time of 47.7 ± 9.8 months. The percentage of images interpreted as normal increased from 45% using the NC images to 72% using AC and to 67% using NC + AC images (P < .001). Hard event hazard ratios for images interpreted as normal were not different between using NC and AC (1.01, P = .99), or NC and NC + AC images (0.97, P = .97). CONCLUSIONS AC lowers the need for additional rest imaging in stress-first MPI using CZT-SPECT, while long-term patient outcome remained identical. Use of AC reduces the need for additional rest imaging, decreasing the mean effective dose by up to 1.2 mSv.
Collapse
Affiliation(s)
- J D van Dijk
- Department of Nuclear Medicine, Isala Hospital, PO Box 10400, 8000 GK, Zwolle, The Netherlands.
- MIRA: Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands.
| | - M Mouden
- Department of Cardiology, Isala Hospital, Zwolle, The Netherlands
| | - J P Ottervanger
- Department of Cardiology, Isala Hospital, Zwolle, The Netherlands
| | - J A van Dalen
- Department of Medical Physics, Isala Hospital, Zwolle, The Netherlands
| | - S Knollema
- Department of Nuclear Medicine, Isala Hospital, PO Box 10400, 8000 GK, Zwolle, The Netherlands
| | - C H Slump
- MIRA: Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
| | - P L Jager
- Department of Nuclear Medicine, Isala Hospital, PO Box 10400, 8000 GK, Zwolle, The Netherlands
| |
Collapse
|
21
|
Henzlova MJ, Duvall WL. What do we know? What do we need to know? J Nucl Cardiol 2017; 24:252-254. [PMID: 27535415 DOI: 10.1007/s12350-016-0640-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Accepted: 07/29/2016] [Indexed: 10/21/2022]
Affiliation(s)
- Milena J Henzlova
- Division of Cardiology, Mount Sinai Medical Center, New York, NY, USA
| | - W Lane Duvall
- Division of Cardiology, Hartford Hospital, Hartford, CT, USA.
| |
Collapse
|
22
|
|
23
|
Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM). Eur J Nucl Med Mol Imaging 2016; 43:2423-2432. [PMID: 27542010 DOI: 10.1007/s00259-016-3467-5] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2016] [Accepted: 07/11/2016] [Indexed: 10/21/2022]
Abstract
The trade-off between resolution and count sensitivity dominates the performance of standard gamma cameras and dictates the need for relatively high doses of radioactivity of the used radiopharmaceuticals in order to limit image acquisition duration. The introduction of cadmium-zinc-telluride (CZT)-based cameras may overcome some of the limitations against conventional gamma cameras. CZT cameras used for the evaluation of myocardial perfusion have been shown to have a higher count sensitivity compared to conventional single photon emission computed tomography (SPECT) techniques. CZT image quality is further improved by the development of a dedicated three-dimensional iterative reconstruction algorithm, based on maximum likelihood expectation maximization (MLEM), which corrects for the loss in spatial resolution due to line response function of the collimator. All these innovations significantly reduce imaging time and result in a lower patient's radiation exposure compared with standard SPECT. To guide current and possible future users of the CZT technique for myocardial perfusion imaging, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, has decided to examine the current literature regarding procedures and clinical data on CZT cameras. The committee hereby aims 1) to identify the main acquisitions protocols; 2) to evaluate the diagnostic and prognostic value of CZT derived myocardial perfusion, and finally 3) to determine the impact of CZT on radiation exposure.
Collapse
|
24
|
Ben-Haim S, Kennedy J, Keidar Z. Novel Cadmium Zinc Telluride Devices for Myocardial Perfusion Imaging—Technological Aspects and Clinical Applications. Semin Nucl Med 2016; 46:273-85. [DOI: 10.1053/j.semnuclmed.2016.01.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
25
|
Acampa W, Buechel RR, Gimelli A. Low dose in nuclear cardiology: state of the art in the era of new cadmium–zinc–telluride cameras. Eur Heart J Cardiovasc Imaging 2016; 17:591-5. [DOI: 10.1093/ehjci/jew036] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2015] [Accepted: 02/13/2016] [Indexed: 01/22/2023] Open
|
26
|
Chikamori T, Hida S, Tanaka N, Igarashi Y, Yamashita J, Shiba C, Murata N, Hoshino K, Hokama Y, Yamashina A. Diagnostic Performance of a Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography System With Low-Dose Technetium-99m as Assessed by Fractional Flow Reserve. Circ J 2016; 80:1217-24. [DOI: 10.1253/circj.cj-16-0087] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
| | - Satoshi Hida
- Department of Cardiology, Tokyo Medical University
| | - Nobuhiro Tanaka
- Department of Cardiology, Tokyo Medical University Hachioji Medical Center
| | | | | | - Chie Shiba
- Department of Cardiology, Tokyo Medical University
| | | | - Kou Hoshino
- Department of Cardiology, Tokyo Medical University
| | - Yohei Hokama
- Department of Cardiology, Tokyo Medical University Hachioji Medical Center
| | | |
Collapse
|
27
|
Caobelli F, Akin M, Thackeray JT, Brunkhorst T, Widder J, Berding G, Burchert I, Bauersachs J, Bengel FM. Diagnostic accuracy of cadmium-zinc-telluride-based myocardial perfusion SPECT: impact of attenuation correction using a co-registered external computed tomography. Eur Heart J Cardiovasc Imaging 2015; 17:1036-43. [PMID: 26628617 DOI: 10.1093/ehjci/jev312] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2015] [Accepted: 10/29/2015] [Indexed: 11/13/2022] Open
Abstract
INTRODUCTION Computed tomography (CT)-based attenuation correction (AC) improves the accuracy of standard myocardial perfusion SPECT. Most dedicated cadmium-zinc-telluride (CZT) SPECT cameras are not equipped with an integrated CT component. We aimed to determine the impact of AC on diagnostic performance of CZT SPECT using co-registration with an external low-dose CT. METHODS Sixty patients underwent CZT SPECT (GE Discovery 530c) with (99m)Tc-sestamibi at rest and following regadenoson stress. Using commercial software, SPECT images were co-registered with a low-dose CT acquired on a separate system (GE Discovery 670NMCT). Attenuation corrected and non-corrected (NC) images were reconstructed using an iterative algorithm. Accuracy was measured in 44 patients who had undergone invasive angiography within 6 months. Normalcy was compared in the remaining 16 patients who had a low pre-test likelihood (<5%) of coronary artery disease (CAD). RESULTS Summed stress and rest scores were significantly lower in AC images (9 ± 8 vs. 13 ± 9 and 6 ± 7 vs. 10 ± 9, P = 0.01), while summed difference score did not differ. According to angiography, 38 patients had significant CAD in 71 vascular territories. Attenuation correction improved accuracy globally (P = 0.03) and in RCA territory (P = 0.008). Specificity improved both globally (100 vs. 40%, P < 0.05) and in each individual territory (LAD: 63 vs. 36%, LCX: 70 vs. 33%, RCA: 81 vs. 19%, P < 0.01). Normalcy was 100% for AC and 62.5% for NC images (P < 0.05). CONCLUSION Attenuation correction with a co-registered external CT is feasible using CZT cameras and improves diagnostic accuracy mostly by improving specificity over uncorrected images.
Collapse
Affiliation(s)
- Federico Caobelli
- Department of Nuclear Medicine, Hannover Medical School, Carl Neuberg Strasse, 1, 30625 Hannover, Germany
| | - Muharrem Akin
- Department of Clinical Cardiology, Hannover Medical School, Hannover, Germany
| | - James T Thackeray
- Department of Nuclear Medicine, Hannover Medical School, Carl Neuberg Strasse, 1, 30625 Hannover, Germany
| | - Thomas Brunkhorst
- Department of Nuclear Medicine, Hannover Medical School, Carl Neuberg Strasse, 1, 30625 Hannover, Germany
| | - Julian Widder
- Department of Clinical Cardiology, Hannover Medical School, Hannover, Germany
| | - Georg Berding
- Department of Nuclear Medicine, Hannover Medical School, Carl Neuberg Strasse, 1, 30625 Hannover, Germany
| | - Ina Burchert
- Department of Nuclear Medicine, Hannover Medical School, Carl Neuberg Strasse, 1, 30625 Hannover, Germany
| | - Johann Bauersachs
- Department of Clinical Cardiology, Hannover Medical School, Hannover, Germany
| | - Frank M Bengel
- Department of Nuclear Medicine, Hannover Medical School, Carl Neuberg Strasse, 1, 30625 Hannover, Germany
| |
Collapse
|
28
|
Yokota S, Mouden M, Ottervanger JP, Engbers E, Knollema S, Timmer JR, Jager PL. Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT. Eur J Nucl Med Mol Imaging 2015; 43:296-301. [DOI: 10.1007/s00259-015-3192-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2015] [Accepted: 09/04/2015] [Indexed: 10/23/2022]
|
29
|
Liu CJ, Wu YW, Ko KY, Chen YC, Cheng MF, Yen RF, Tzen KY. Incremental Diagnostic Performance of Combined Parameters in the Detection of Severe Coronary Artery Disease Using Exercise Gated Myocardial Perfusion Imaging. PLoS One 2015; 10:e0134485. [PMID: 26230651 PMCID: PMC4521811 DOI: 10.1371/journal.pone.0134485] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Accepted: 07/10/2015] [Indexed: 11/18/2022] Open
Abstract
Purpose Myocardial perfusion imaging (MPI) using gated single-photon emission tomography (gSPECT) may underestimate the severity of coronary artery disease (CAD). This study aimed to evaluate the significance of combined parameters derived from gSPECT, as well as treadmill stress test parameters, in the detection of severe CAD. Methods A total of 211 consecutive patients referred for exercise MPI between June 2011 and June 2013 (who received invasive coronary angiography within six months after MPI) were retrospectively reviewed. Exercise MPI was performed with Bruce protocol and 201Tl injected at peak exercise. Gated SPECT was performed using a cadmium-zinc-telluride camera and processed by QPS/QGS software. Perfusion defect abnormalities such as sum stress score (SSS); sum difference score, algorithm-derived total perfusion deficits, transient ischemic dilatation ratios of end-diastolic volumes and end-systolic volumes, post-stress changes in ejection fraction, and lung/heart ratio (LHR) were calculated. Treadmill parameters, including ST depression (STD) at the 1st and 3rd minutes of recovery stage (1’STD and 3’STD), maximal STD corrected by heart rate increment (ST/HR), heart rate decline in 1st and 3rd minutes of recovery stage, recovery heart rate ratio (HR ratio), systolic and mean blood pressure ratios (SBP ratio and MAP ratio) during recovery phase were recorded. Diagnostic performances of these parameters were analyzed with receiver operating characteristic (ROC) analysis and logistic regression for detection of left main (≥ 50%) or 3-vessel disease (all ≥ 70% luminal stenosis) on invasive angiography. Results Among various MPI and treadmill parameters used for detection of severe CAD, SSS and ST/HR had the highest AUC (0.78, 0.73, p = NS) and best cut-off values (SSS > 6, ST/HR > 17.39 10-2mV/bpm), respectively. By univariate logistic regression, all parameters except 1’HRR, 3’HRR, SBP and MAP ratios increased the odds ratio of severe CAD. Only increased L/H ratio, 3’STD, and HR ratio remained significant after multivariate regression. The predicted values of combined MPI and treadmill parameters (LHR, 3’STD, and HR ratio) gave the best ROC (AUC: 0.91) than any individual parameter or parameter combination. Conclusions Of all treadmill and gSPECT parameters, the combination of MPI and treadmill parameters can offer better diagnostic performance for severe CAD.
Collapse
Affiliation(s)
- Chia-Ju Liu
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Yen-Wen Wu
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
- Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan
- Department of Nuclear Medicine, Far-Eastern Memorial Hospital, New Taipei City, Taiwan
- Cardiology Division of Cardiovascular Medical Center, Far-Eastern Memorial Hospital, New Taipei City, Taiwan
- National Yang-Ming University School of Medicine, Taipei, Taiwan
- * E-mail:
| | - Kuan-Yin Ko
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Yi-Chieh Chen
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Mei-Fang Cheng
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Ruoh-Fang Yen
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Kai-Yuan Tzen
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| |
Collapse
|
30
|
Edvardsen T, Bucciarelli-Ducci C, Saraste A, Pierard LA, Knuuti J, Maurer G, Habib G, Lancellotti P. The year 2014 in the European Heart Journal - Cardiovascular Imaging. Part I. Eur Heart J Cardiovasc Imaging 2015; 16:712-8. [DOI: 10.1093/ehjci/jev150] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
|
31
|
|
32
|
A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism. Heart Vessels 2014; 31:38-45. [DOI: 10.1007/s00380-014-0578-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2014] [Accepted: 08/29/2014] [Indexed: 11/26/2022]
|