1
|
Spanaki A, Kabir S, Stephenson N, van Poppel MPM, Benetti V, Simpson J. 3D Approaches in Complex CHD: Where Are We? Funny Printing and Beautiful Images, or a Useful Tool? J Cardiovasc Dev Dis 2022; 9:269. [PMID: 36005432 PMCID: PMC9410138 DOI: 10.3390/jcdd9080269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 08/02/2022] [Accepted: 08/05/2022] [Indexed: 11/16/2022] Open
Abstract
Echocardiography, CT and MRI have a crucial role in the management of congenital heart disease (CHD) patients. All of these modalities can be presented in a 2D or a 3D rendered format. The aim of this paper is to review the key advantages and potential limitations, as well as the future challenges of a 3D approach in each imaging modality. The focus of this review is on anatomic rather than functional assessment. Conventional 2D echocardiography presents limitations when imaging complex lesions, whereas 3D imaging depicts the anatomy in all dimensions. CT and MRI can visualise extracardiac vasculature and guide complex biventricular repair. Three-dimensional printed models can be used in depicting complex intracardiac relationships and defining the surgical strategy in specific lesions. Extended reality imaging retained dynamic cardiac motion holds great potential for planning surgical and catheter procedures. Overall, the use of 3D imaging has resulted in a better understanding of anatomy, with a direct impact on the surgical and catheter approach, particularly in more complex cases.
Collapse
Affiliation(s)
- Adriani Spanaki
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London SE1 7EH, UK
| | - Saleha Kabir
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London SE1 7EH, UK
| | - Natasha Stephenson
- School of Biomedical Engineering & Imaging Sciences, King’s College London, King’s Health Partners, St Thomas’ Hospital, London SE1 7EH, UK
| | - Milou P. M. van Poppel
- School of Biomedical Engineering & Imaging Sciences, King’s College London, King’s Health Partners, St Thomas’ Hospital, London SE1 7EH, UK
| | - Valentina Benetti
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London SE1 7EH, UK
| | - John Simpson
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London SE1 7EH, UK
- School of Biomedical Engineering & Imaging Sciences, King’s College London, King’s Health Partners, St Thomas’ Hospital, London SE1 7EH, UK
| |
Collapse
|
2
|
Arbic N, Venet M, Iriart X, Dragulescu A, Thambo JB, Friedberg MK, Guerra V, Morgan CT, Mertens L, Villemain O. Organization of Pediatric Echocardiography Laboratories: Impact of Sonographers on Clinical, Academic, and Financial Performance. Front Pediatr 2022; 10:891360. [PMID: 35712633 PMCID: PMC9196029 DOI: 10.3389/fped.2022.891360] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 05/10/2022] [Indexed: 11/23/2022] Open
Abstract
Echocardiography has evolved the first-line imaging for diagnosis and management of pediatric and congenital heart disease all over the world. While it recognized as essential component of pediatric cardiac care delivery, organization of pediatric echocardiography services is very heterogeneous across the world, mainly related to significant differences in material and human resources in heterogeneous health care systems. In this paper, we focus on the role of pediatric sonographers, defined as expert technicians in pediatric echocardiography. While in some services sonographers are an essential part of the organizational structure, other laboratories operate only with physicians trained in echocardiography. The impact of sonographers on clinical, academic and financial performance will be discussed. Two organizational models (with and without sonographers) will be compared, and the advantages and disadvantages of each model will be evaluated. Different models of care provision are possible and decisions on organizational models need to be adjusted to the demands and available resources.
Collapse
Affiliation(s)
- Nick Arbic
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Maelys Venet
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Xavier Iriart
- Department of Pediatric and Adult Congenital Cardiology, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Bordeaux, France.,IHU LIRYC Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Bordeaux, France
| | - Andreea Dragulescu
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Jean-Benoit Thambo
- Department of Pediatric and Adult Congenital Cardiology, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Bordeaux, France.,IHU LIRYC Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Bordeaux, France
| | - Mark K Friedberg
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Vitor Guerra
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Conall Thomas Morgan
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Luc Mertens
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Olivier Villemain
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
3
|
Cai W, Wang Y, Gu L, Ji X, Shen Q, Ren X. Detection of 3D Arterial Centerline Extraction in Spiral CT Coronary Angiography. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:2670793. [PMID: 34471506 PMCID: PMC8405334 DOI: 10.1155/2021/2670793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Revised: 08/08/2021] [Accepted: 08/12/2021] [Indexed: 11/17/2022]
Abstract
This paper presents an in-depth study and analysis of the 3D arterial centerline in spiral CT coronary angiography, and constructs its detection and extraction technique. The first time, the distance transform is used to complete the boundary search of the original figure; the second time, the distance transform is used to calculate the value of the distance transform of all voxels, and according to the value of the distance transform, unnecessary voxels are deleted, to complete the initial contraction of the vascular region and reduce the computational consumption in the next process; then, the nonwitnessed voxels are used to construct the maximum inner joint sphere model and find the skeletal voxels that can reflect the shape of the original figure. Finally, the skeletal lines were optimized on these initially extracted skeletal voxels using a dichotomous-like principle to obtain the final coronary artery centerline. Through the evaluation of the experimental results, the algorithm can extract the coronary centerline more accurately. In this paper, the segmentation method is evaluated on the test set data by two kinds of indexes: one is the index of segmentation result evaluation, including dice coefficient, accuracy, specificity, and sensitivity; the other is the index of clinical diagnosis result evaluation, which is to refine the segmentation result for vessel diameter detection. The results obtained in this paper were compared with the physicians' labeling results. In terms of network performance, the Dice coefficient obtained in this paper was 0.89, the accuracy was 98.36%, the sensitivity was 93.36%, and the specificity was 98.76%, which reflected certain advantages in comparison with the advanced methods proposed by previous authors. In terms of clinical evaluation indexes, by performing skeleton line extraction and diameter calculation on the results obtained by the segmentation method proposed in this paper, the absolute error obtained after comparing with the diameter of the labeled image was 0.382 and the relative error was 0.112, which indicates that the segmentation method in this paper can recover the vessel contour more accurately. Then, the results of coronary artery centerline extraction with and without fine branch elimination were evaluated, which proved that the coronary artery centerline has higher accuracy after fine branch elimination. The algorithm is also used to extract the centerline of the complete coronary artery tree, and the results prove that the algorithm has better results for the centerline extraction of the complete coronary vascular tree.
Collapse
Affiliation(s)
- Wenjuan Cai
- Changshu Hospital of Chinese Medicine, Changshu 215516, Jiangsu, China
| | - Yanzhe Wang
- Changshu Hospital of Chinese Medicine, Changshu 215516, Jiangsu, China
| | - Liya Gu
- Changshu Hospital of Chinese Medicine, Changshu 215516, Jiangsu, China
| | - Xuefeng Ji
- Changshu Hospital of Chinese Medicine, Changshu 215516, Jiangsu, China
| | - Qiusheng Shen
- Changshu Hospital of Chinese Medicine, Changshu 215516, Jiangsu, China
| | - Xiaogang Ren
- Changshu Hospital of Chinese Medicine, Changshu 215516, Jiangsu, China
- School of Information and Control Engineering, China University of Mining and Technology, Xuzhou 221116, Jiangsu, China
| |
Collapse
|
4
|
Spatiotemporal registration and fusion of transthoracic echocardiography and volumetric coronary artery tree. Int J Comput Assist Radiol Surg 2021; 16:1493-1505. [PMID: 34101135 DOI: 10.1007/s11548-021-02421-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Accepted: 05/26/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE Cardiac multimodal image fusion can offer an image with various types of information in a single image. Many coronary stenosis, which are anatomically clear, are not functionally significant. The treatment of such kind of stenosis can cause irreversible effects on the patient. Thus, choosing the best treatment planning depend on anatomical and functional information is very beneficial. METHODS An algorithm for the fusion of coronary computed tomography angiography (CCTA) as an anatomical and transthoracic echocardiography (TTE) as a functional modality is presented. CCTA and TTE are temporally registered using manifold learning. A pattern search optimization algorithm, using normalized mutual information, is used to find the best match slice to TTE frame from CCTA volume. By employing a free-form deformation, the heart's non-rigid deformations are modeled. The spatiotemporal registered TTE frame is embedded to achieve the fusion result. RESULTS The accuracy is evaluated on CCTA and TTE data obtained from 10 patients. In temporal registration, mean absolute error of 1.97 [Formula: see text] 1.23 is resulted from comparing the output frame numbers from the algorithm and from manual assignment by an expert. In spatial registration, the accuracy of the similarity between the best match slice from CCTA volume and TTE frame is resulted in 1.82 [Formula: see text] 0.024 mm, 6.74 [Formula: see text] 0.013 mm, and 0.901 [Formula: see text] 0.0548 due to mean absolute distance, Hausdorff distance, and Dice similarity coefficient, respectively. CONCLUSION Without the use of ECG and Optical tracking systems, a semiautomatic framework of spatiotemporal registration and fusion of CCTA volume and TTE frame is presented. The experimental results showed the effectiveness of our proposed method to create complementary information from TTE and CCTA, which may help in the early diagnosis and effective treatment of cardiovascular diseases (CVDs).
Collapse
|
5
|
Takaya Y, Nakayama R, Watanabe N, Toh N, Miyoshi T, Ito H. Fusion imaging of three-dimensional echocardiographic speckle-tracking with cardiac computed tomography for identification of myocardial ischemia. Health Sci Rep 2021; 4:e285. [PMID: 34189272 PMCID: PMC8213415 DOI: 10.1002/hsr2.285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Revised: 03/07/2021] [Accepted: 04/13/2021] [Indexed: 11/05/2022] Open
Affiliation(s)
- Yoichi Takaya
- Department of Cardiovascular MedicineOkayama University Graduate School of Medicine, Dentistry and Pharmaceutical SciencesOkayamaJapan
| | - Rie Nakayama
- Department of Cardiovascular MedicineOkayama University Graduate School of Medicine, Dentistry and Pharmaceutical SciencesOkayamaJapan
| | | | - Norihisa Toh
- Department of Cardiovascular MedicineOkayama University Graduate School of Medicine, Dentistry and Pharmaceutical SciencesOkayamaJapan
| | - Toru Miyoshi
- Department of Cardiovascular MedicineOkayama University Graduate School of Medicine, Dentistry and Pharmaceutical SciencesOkayamaJapan
| | - Hiroshi Ito
- Department of Cardiovascular MedicineOkayama University Graduate School of Medicine, Dentistry and Pharmaceutical SciencesOkayamaJapan
| |
Collapse
|
6
|
Nabeshima Y, Seo Y, Takeuchi M. A review of current trends in three-dimensional analysis of left ventricular myocardial strain. Cardiovasc Ultrasound 2020; 18:23. [PMID: 32591001 PMCID: PMC7320541 DOI: 10.1186/s12947-020-00204-3] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 06/15/2020] [Indexed: 12/19/2022] Open
Abstract
Three-dimensional (3D) left ventricular (LV) myocardial strain measurements using transthoracic 3D echocardiography speckle tracking analysis have several advantages over two-dimensional (2D) LV strain measurements, because 3D strain values are derived from the entire LV myocardium, yielding more accurate estimates of global and regional LV function. In this review article, we summarize the current status of 3D LV myocardial strain. Specifically, we describe how 3D LV strain analysis is performed. Next, we compare characteristics of 2D and 3D strain, and we explain validation of 3D strain measurements, feasibility and measurement differences between 2D and 3D strain, reference values of 3D strain, and its applications in several clinical scenarios. In some parts of this review, we used a meta-analysis to draw reliable conclusions. We also describe the added value of 3D over 2D strain in several specific pathologies and prognoses. Finally, we discuss novel techniques using 3D strain and suggest its future directions.
Collapse
Affiliation(s)
- Yosuke Nabeshima
- Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi, Kitakyushu, 807-8555, Japan.
| | - Yoshihiro Seo
- Department of Cardiology, Graduate School of Medical Sciences, Nagoya City University, Nagoya, Japan
| | - Masaaki Takeuchi
- Department of Laboratory and Transfusion Medicine, School of Medicine, Hospital of University of Occupational and Environmental Health, Kitakyushu, Japan
| |
Collapse
|
7
|
Nudi F, Biondi-Zoccai G, Romagnoli A, Schillaci O, Nudi A, Versaci F. Hybrid anatomo-functional imaging of coronary artery disease: Beneficial irrespective of its core components. J Nucl Cardiol 2019; 26:752-762. [PMID: 30565061 DOI: 10.1007/s12350-018-01562-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2018] [Accepted: 09/19/2018] [Indexed: 02/05/2023]
Abstract
Coronary artery disease (CAD) is the most common and important cause of ischemic heart disease, with major implications on global morbidity and mortality. Non-invasive testing is crucial in the diagnostic and prognostic work-up of patients with or at risk of CAD, and also to guide decision making in terms of pharmacologic and revascularization therapy. The traditional paradigm is to view anatomic (i.e., coronary computed tomography) and functional imaging (e.g., myocardial perfusion scintigraphy) tests as opposing alternatives. Such approach is too reductionist and does not capitalize on the strengths of each type of test while risking to overlook the inherent limitations. The combination of anatomic and functional tests in a logic of hybrid imaging holds the promise of overcoming the limitations inherent to anatomic and functional testing, enabling more accurate diagnosis, prognosis, and guidance for revascularization in patients with CAD.
Collapse
Affiliation(s)
- Francesco Nudi
- Service of Hybrid Cardio Imaging, Madonna Della Fiducia Clinic, Rome, Italy.
- Ostia Radiologica, Rome, Italy.
- Replycare, Viale Africa 36, 00144, Rome, Italy.
| | - Giuseppe Biondi-Zoccai
- Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy
- IRCCS NEUROMED, Pozzilli, Italy
| | | | - Orazio Schillaci
- IRCCS NEUROMED, Pozzilli, Italy
- Department of Nuclear Medicine, Tor Vergata University, Rome, Italy
| | - Alessandro Nudi
- Service of Hybrid Cardio Imaging, Madonna Della Fiducia Clinic, Rome, Italy
- Replycare, Viale Africa 36, 00144, Rome, Italy
| | | |
Collapse
|
8
|
Patel AR, Maffessanti F, Patel MB, Kebed K, Narang A, Singh A, Medvedofsky D, Zaidi SJ, Mediratta A, Goyal N, Kachenoura N, Lang RM, Mor-Avi V. Hemodynamic impact of coronary stenosis using computed tomography: comparison between noninvasive fractional flow reserve and 3D fusion of coronary angiography with stress myocardial perfusion. Int J Cardiovasc Imaging 2019; 35:1733-1743. [PMID: 31073698 DOI: 10.1007/s10554-019-01618-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Accepted: 04/30/2019] [Indexed: 01/06/2023]
Abstract
Vasodilator-stress CT perfusion imaging in addition to CT coronary angiography (CTCA) may provide a single-test alternative to nuclear stress testing, commonly used to assess hemodynamic significance of stenosis. Another alternative is fractional flow reserve (FFR) calculated from cardiac CT images. We studied the concordance between these two approaches and their relationship to outcomes. We prospectively studied 150 patients with chest pain, who underwent CTCA and regadenoson CT. CTCA images were interpreted for presence and severity of stenosis. Fused 3D displays of subendocardial X-ray attenuation with coronary arteries were created to detect stress perfusion defects (SPD) in each coronary territory. In patients with stenosis > 25%, CT-FFR was quantified. Significant stenosis was determined by: (1) combination of stenosis > 50% with an SPD, (2) CT-FFR ≤ 0.80. Patients were followed-up for 36 ± 25 months for death, myocardial infarction or revascularization. After excluding patients with normal arteries and technical/quality issues, in final analysis of 76 patients, CTCA depicted stenosis > 70% in 13/224 arteries, 50-70% in 24, and < 50% in 187. CT-FFR ≤ 0.80 was found in 41/224 arteries, and combination of SPD with > 50% stenosis in 31/224 arteries. Inter-technique agreement was 89%. Despite high incidence of abnormal CT-FFR (30/76 patients), only 7 patients experienced adverse outcomes; 6/7 also had SPDs. Only 1/9 patients with CT-FFR ≤ 0.80 but normal perfusion had an event. Fusion of CTCA and stress perfusion can help determine the hemodynamic impact of stenosis in one test, in good agreement with CT-FFR. Adding stress CT perfusion analysis may help risk-stratify patients with abnormal CT-FFR.
Collapse
Affiliation(s)
- Amit R Patel
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA
| | - Francesco Maffessanti
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA.,Institute of Computational Sciences, Università della Svizzera Italiana, Lugano, Switzerland
| | - Mita B Patel
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA
| | - Kalie Kebed
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA
| | - Akhil Narang
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA
| | - Amita Singh
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA
| | - Diego Medvedofsky
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA
| | - S Javed Zaidi
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA.,Cardiology Department, Advocate Children's Hospital, Chicago, IL, USA
| | - Anuj Mediratta
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA
| | - Neha Goyal
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA
| | - Nadjia Kachenoura
- Laboratoire d'Imagerie Biomédicale, INSERM, CNRS, Sorbonne Université, Paris, France
| | - Roberto M Lang
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA
| | - Victor Mor-Avi
- Department of Medicine, Section of Cardiology, University of Chicago Medical Center, 5758 South Maryland Avenue, M.C. 9067, Chicago, IL, 60637, USA.
| |
Collapse
|
9
|
Narang A, Mor-Avi V, Prado A, Volpato V, Prater D, Tamborini G, Fusini L, Pepi M, Goyal N, Addetia K, Gonçalves A, Patel AR, Lang RM. Machine learning based automated dynamic quantification of left heart chamber volumes. Eur Heart J Cardiovasc Imaging 2019; 20:541-549. [PMID: 30304500 PMCID: PMC6933871 DOI: 10.1093/ehjci/jey137] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Accepted: 09/13/2018] [Indexed: 12/19/2022] Open
Abstract
AIMS Studies have demonstrated the ability of a new automated algorithm for volumetric analysis of 3D echocardiographic (3DE) datasets to provide accurate and reproducible measurements of left ventricular and left atrial (LV, LA) volumes at end-systole and end-diastole. Recently, this methodology was expanded using a machine learning (ML) approach to automatically measure chamber volumes throughout the cardiac cycle, resulting in LV and LA volume-time curves. We aimed to validate ejection and filling parameters obtained from these curves by comparing them to independent well-validated reference techniques. METHODS AND RESULTS We studied 20 patients referred for cardiac magnetic resonance (CMR) examinations, who underwent 3DE imaging the same day. Volume-time curves were obtained for both LV and LA chambers using the ML algorithm (Philips HeartModel), and independently conventional 3DE volumetric analysis (TomTec), and CMR images (slice-by-slice, frame-by-frame manual tracing). Automatically derived LV and LA volumes and ejection/filling parameters were compared against both reference techniques. Minor manual correction of the automatically detected LV and LA borders was needed in 4/20 and 5/20 cases, respectively. Time required to generate volume-time curves was 35 ± 17 s using ML algorithm, 3.6 ± 0.9 min using conventional 3DE analysis, and 96 ± 14 min using CMR. Volume-time curves obtained by all three techniques were similar in shape and magnitude. In both comparisons, ejection/filling parameters showed no significant inter-technique differences. Bland-Altman analysis confirmed small biases, despite wide limits of agreement. CONCLUSION The automated ML algorithm can quickly measure dynamic LV and LA volumes and accurately analyse ejection/filling parameters. Incorporation of this algorithm into the clinical workflow may increase the utilization of 3DE imaging.
Collapse
Affiliation(s)
- Akhil Narang
- Department of Medicine, University of Chicago Medical Center, 5758 South Maryland Ave, MC 9067 Room 5513, Chicago, IL, USA
| | - Victor Mor-Avi
- Department of Medicine, University of Chicago Medical Center, 5758 South Maryland Ave, MC 9067 Room 5513, Chicago, IL, USA
| | - Aldo Prado
- Centro Privado de Cardiologia, Yerba Buena, Virgen de la Merced 550, Tucumán, Argentina
| | - Valentina Volpato
- Department of Medicine, University of Chicago Medical Center, 5758 South Maryland Ave, MC 9067 Room 5513, Chicago, IL, USA
- Department of Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Via Parea 4, Milan, Italy
| | - David Prater
- Philips Healthcare, 3000 Minuteman Road, Andover, MA, USA
| | - Gloria Tamborini
- Department of Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Via Parea 4, Milan, Italy
| | - Laura Fusini
- Department of Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Via Parea 4, Milan, Italy
| | - Mauro Pepi
- Department of Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Via Parea 4, Milan, Italy
| | - Neha Goyal
- Department of Medicine, University of Chicago Medical Center, 5758 South Maryland Ave, MC 9067 Room 5513, Chicago, IL, USA
| | - Karima Addetia
- Department of Medicine, University of Chicago Medical Center, 5758 South Maryland Ave, MC 9067 Room 5513, Chicago, IL, USA
| | | | - Amit R Patel
- Department of Medicine, University of Chicago Medical Center, 5758 South Maryland Ave, MC 9067 Room 5513, Chicago, IL, USA
| | - Roberto M Lang
- Department of Medicine, University of Chicago Medical Center, 5758 South Maryland Ave, MC 9067 Room 5513, Chicago, IL, USA
| |
Collapse
|
10
|
Fusion of Three-Dimensional Echocardiographic Regional Myocardial Strain with Cardiac Computed Tomography for Noninvasive Evaluation of the Hemodynamic Impact of Coronary Stenosis in Patients with Chest Pain. J Am Soc Echocardiogr 2018; 31:664-673. [PMID: 29576220 DOI: 10.1016/j.echo.2018.01.019] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Indexed: 12/31/2022]
Abstract
BACKGROUND Combined evaluation of coronary stenosis and the extent of ischemia is essential in patients with chest pain. Intermediate-grade stenosis on computed tomographic coronary angiography (CTCA) frequently triggers downstream nuclear stress testing. Alternative approaches without stress and/or radiation may have important implications. Myocardial strain measured from echocardiographic images can be used to detect subclinical dysfunction. The authors recently tested the feasibility of fusion of three-dimensional (3D) echocardiography-derived regional resting longitudinal strain with coronary arteries from CTCA to determine the hemodynamic significance of stenosis. The aim of the present study was to validate this approach against accepted reference techniques. METHODS Seventy-eight patients with chest pain referred for CTCA who also underwent 3D echocardiography and regadenoson stress computed tomography were prospectively studied. Left ventricular longitudinal strain data (TomTec) were used to generate fused 3D displays and detect resting strain abnormalities (RSAs) in each coronary territory. Computed tomographic coronary angiographic images were interpreted for the presence and severity of stenosis. Fused 3D displays of subendocardial x-ray attenuation were created to detect stress perfusion defects (SPDs). In patients with stenosis >25% in at least one artery, fractional flow reserve was quantified (HeartFlow). RSA as a marker of significant stenosis was validated against two different combined references: stenosis >50% on CTCA and SPDs seen in the same territory (reference standard A) and fractional flow reserve < 0.80 and SPDs in the same territory (reference standard B). RESULTS Of the 99 arteries with no stenosis >50% and no SPDs, considered as normal, 19 (19%) had RSAs. Conversely, with stenosis >50% and SPDs, RSAs were considerably more frequent (17 of 24 [71%]). The sensitivity, specificity, and accuracy of RSA were 0.71, 0.81, and 0.79, respectively, against reference standard A and 0.83, 0.81, and 0.82 against reference standard B. CONCLUSIONS Fusion of CTCA and 3D echocardiography-derived resting myocardial strain provides combined displays, which may be useful in determination of the hemodynamic or functional impact of coronary abnormalities, without additional ionizing radiation or stress testing.
Collapse
|
11
|
Medvedofsky D, Mor-Avi V, Byku I, Singh A, Weinert L, Yamat M, Kruse E, Ciszek B, Nelson A, Otani K, Takeuchi M, Lang RM. Three-Dimensional Echocardiographic Automated Quantification of Left Heart Chamber Volumes Using an Adaptive Analytics Algorithm: Feasibility and Impact of Image Quality in Nonselected Patients. J Am Soc Echocardiogr 2017; 30:879-885. [PMID: 28688857 DOI: 10.1016/j.echo.2017.05.018] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Indexed: 11/18/2022]
Abstract
BACKGROUND Although 3D echocardiography (3DE) allows accurate and reproducible quantification of cardiac chambers, it has not been integrated into clinical practice because it relies on manual input, which interferes with workflow. A recently developed automated adaptive analytics algorithm for simultaneous quantification of left ventricular and atrial (LV, LA) volumes was found to be accurate and reproducible in patients with good images. We sought to prospectively test its feasibility and accuracy in consecutive patients in relationship with image quality and reader experience. METHODS Three hundred consecutive patients underwent 3DE. Image quality was graded as poor, adequate, or good. Images were analyzed by an expert echocardiographer to obtain LV volumes and ejection fraction (EF) and LA volume using the automated analysis (HeartModel, Philips, Andover, MA) with and without editing the endocardial boundaries and using conventional manual tracing (QLAB, Philips, Andover, MA) blinded to the automated measurements as a reference. In a subgroup of 100 patients, automated analysis was repeated by two readers without 3DE experience. RESULTS Automated analysis failed in 31/300 patients (10%). Patients with poor image quality (n = 72, 24%) showed suboptimal agreement with the reference technique, especially for LVEF. Importantly, patients with adequate (n = 89, 30%) and good (n = 108, 36%) images showed small biases and excellent correlations without border corrections, which were further improved with editing. In contrast, border corrections by inexperienced readers did not improve the agreement with reference values. CONCLUSIONS Automated 3DE analysis allows accurate quantification of left-heart size and function in 66% of consecutive patients, while in the remaining patients, its performance is limited/unreliable due to image quality. Border corrections require 3DE experience to improve the accuracy of the automated measurements. In patients with sufficient image quality, this automated approach has the potential to overcome the workflow limitations of the 3D analysis in clinical practice.
Collapse
Affiliation(s)
- Diego Medvedofsky
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Victor Mor-Avi
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
| | - Isida Byku
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Amita Singh
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Lynn Weinert
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Megan Yamat
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Eric Kruse
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Boguslawa Ciszek
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Alma Nelson
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Kyoko Otani
- University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Masaaki Takeuchi
- University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Roberto M Lang
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| |
Collapse
|
12
|
Delgado V, Gaemperli O, Lombardi M, Kaufmann PA, Bax JJ. The year in cardiology 2016: imaging. Eur Heart J 2017; 38:390-399. [PMID: 28043972 DOI: 10.1093/eurheartj/ehw633] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2016] [Accepted: 12/21/2016] [Indexed: 12/11/2022] Open
Affiliation(s)
- Victoria Delgado
- Heart Lung Centrum, Leiden University Medical Center, Albinusdreef 2, 2300 RC, Leiden, The Netherlands
| | - Oliver Gaemperli
- Cardiac Imaging, University Heart Center, Moussonstrasse 4, CH 8091 Zurich, Switzerland
| | - Massimo Lombardi
- Multimodality Cardiac Imaging Section, IRCCS Policlinico San Donato, Piazza Edmondo Malan, 1, 20097 San Donato Milanese Milan, Italy
| | - Philipp A Kaufmann
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Raemistr 100, 809 1 Zürich, Switzerland
| | - Jeroen J Bax
- Heart Lung Centrum, Leiden University Medical Center, Albinusdreef 2, 2300 RC, Leiden, The Netherlands
| |
Collapse
|