1
|
Messina A, Calabrò L, Pugliese L, Lulja A, Sopuch A, Rosalba D, Morenghi E, Hernandez G, Monnet X, Cecconi M. Fluid challenge in critically ill patients receiving haemodynamic monitoring: a systematic review and comparison of two decades. Crit Care 2022; 26:186. [PMID: 35729632 PMCID: PMC9210670 DOI: 10.1186/s13054-022-04056-3] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 06/07/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Introduction
Fluid challenges are widely adopted in critically ill patients to reverse haemodynamic instability. We reviewed the literature to appraise fluid challenge characteristics in intensive care unit (ICU) patients receiving haemodynamic monitoring and considered two decades: 2000–2010 and 2011–2021.
Methods
We assessed research studies and collected data regarding study setting, patient population, fluid challenge characteristics, and monitoring. MEDLINE, Embase, and Cochrane search engines were used. A fluid challenge was defined as an infusion of a definite quantity of fluid (expressed as a volume in mL or ml/kg) in a fixed time (expressed in minutes), whose outcome was defined as a change in predefined haemodynamic variables above a predetermined threshold.
Results
We included 124 studies, 32 (25.8%) published in 2000–2010 and 92 (74.2%) in 2011–2021, overall enrolling 6,086 patients, who presented sepsis/septic shock in 50.6% of cases. The fluid challenge usually consisted of 500 mL (76.6%) of crystalloids (56.6%) infused with a rate of 25 mL/min. Fluid responsiveness was usually defined by a cardiac output/index (CO/CI) increase ≥ 15% (70.9%). The infusion time was quicker (15 min vs 30 min), and crystalloids were more frequent in the 2011–2021 compared to the 2000–2010 period.
Conclusions
In the literature, fluid challenges are usually performed by infusing 500 mL of crystalloids bolus in less than 20 min. A positive fluid challenge response, reported in 52% of ICU patients, is generally defined by a CO/CI increase ≥ 15%. Compared to the 2000–2010 decade, in 2011–2021 the infusion time of the fluid challenge was shorter, and crystalloids were more frequently used.
Collapse
|
2
|
Chabchoub S, Mansouri S, Ben Salah R. Signal processing techniques applied to impedance cardiography ICG signals - a review. J Med Eng Technol 2022; 46:243-260. [PMID: 35040738 DOI: 10.1080/03091902.2022.2026508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Over the last decade, Computer-Aided Diagnosis (CAD) systems have been provided significant research focus by researchers. CAD systems have been developed in order to minimise visual errors, to compensate manual interpretation, and to help medical staff to take decisions swiftly. These systems have been considered as powerful tools for a reliable, automatic, and low-cost monitoring and diagnosis. CAD systems are based on analysis and classification of several physiological signals for detecting and assessing different diseases related to the corresponding organ. The implementation of these systems requires the application of several advanced signal processing techniques. Specifically, in cardiology, CAD systems have achieved promising results in providing an accurate and rapid detection of cardiovascular diseases (CVDs). Particularly, the number of works on signal processing field for impedance cardiography (ICG) signals starts to grow slowly in recent years. This paper presents a review study of signal processing techniques applied to the ICG signal for the denoising, the analysis, the classification and the characterisation purposes. This review is intended to provide researchers with a broad overview of the currently used signal processing techniques for ICG signal analysis, as well as to improve future research by applying other recent advanced methods.
Collapse
Affiliation(s)
- Souhir Chabchoub
- Laboratory of Biophysics and Medical Technologies, University of Tunis El-Manar, ISTMT, Tunis, Tunisia
| | - Sofienne Mansouri
- Laboratory of Biophysics and Medical Technologies, University of Tunis El-Manar, ISTMT, Tunis, Tunisia.,Department of Medical Equipment Technology, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Al-Kharj, Kingdom of Saudi Arabia
| | - Ridha Ben Salah
- Laboratory of Biophysics and Medical Technologies, University of Tunis El-Manar, ISTMT, Tunis, Tunisia
| |
Collapse
|
3
|
Yanase F, Naorungroj T, Cutuli SL, Eastwood GM, Bellomo R. Rapid 500 mL albumin bolus versus rapid 200 mL bolus followed by slower continuous infusion in post-cardiac surgery patients: a pilot before-and-after study. CRIT CARE RESUSC 2021; 23:320-328. [PMID: 38046079 PMCID: PMC10692547 DOI: 10.51893/2021.3.oa9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Objective: To evaluate the haemodynamic effects of rapid fluid bolus therapy (FBT) (500 mL of 4% albumin over several minutes) versus combined FBT (rapid 200 mL FBT followed by a 300 mL infusion over 30 minutes). Design: Single centre, prospective, before-and-after trial. Setting: A tertiary intensive care unit in Australia. Participants: Fifty mechanically ventilated post-cardiac surgery patients. Interventions: Rapid 4% albumin FBT versus combined FBT. Main outcome measures: We recorded haemodynamic parameters from before FBT to 30 minutes after FBT. A mean arterial pressure (MAP) response was defined by a MAP increase > 10%, and a cardiac index (CI) response was defined by a CI increase > 15%. Results: Immediately after rapid FBT versus combined FBT, there was a CI response in 13 patients (52%) compared with five patients (20%) respectively (P = 0.038), and a MAP response in 11 patients (44%) in each group. However, from FBT administration to 30 minutes, there was a time and group interaction such that MAP was higher in the rapid FBT group (P = 0.003), as was the case for central venous pressure (P = 0.002) and mean pulmonary artery pressure (P < 0.001). Body temperature fell immediately and was lower with rapid FBT but became warmer than with combined FBT later (P < 0.001). At 30 minutes, a MAP response was seen in ten patients (40%) compared with nine patients (36%) (P < 0.99) and a CI response was present in eight patients (32%) compared with 11 patients (44%) (P = 0.56) in the rapid versus combined FBT groups respectively. Conclusion: Rapid FBT was superior to combined FBT in terms of mean MAP levels and immediate CI response. However, the number of MAP responders or CI responders was similar at 30 minutes.
Collapse
Affiliation(s)
- Fumitaka Yanase
- Department of Intensive Care, Austin Hospital, Melbourne, Victoria, Australia
- Australian and New Zealand Intensive Care Research Centre (ANZIC-RC), School of Public Health and Preventive Medicine, Monash University, Melbourne, Victoria, Australia
| | - Thummaporn Naorungroj
- Department of Intensive Care, Austin Hospital, Melbourne, Victoria, Australia
- Department of Intensive Care, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Salvatore L. Cutuli
- Department of Intensive Care, Austin Hospital, Melbourne, Victoria, Australia
- Dipartimento di Scienze dell’emergenza, anestesiologiche e della Rianimazione, Fondazione Policlinico Universitario A Gemelli IRCCS, Rome, Italy
| | - Glenn M. Eastwood
- Department of Intensive Care, Austin Hospital, Melbourne, Victoria, Australia
| | - Rinaldo Bellomo
- Department of Intensive Care, Austin Hospital, Melbourne, Victoria, Australia
- Australian and New Zealand Intensive Care Research Centre (ANZIC-RC), School of Public Health and Preventive Medicine, Monash University, Melbourne, Victoria, Australia
- Centre for Integrated Critical Care, School of Medicine, University of Melbourne, Melbourne, Victoria, Australia
| |
Collapse
|
4
|
Harper KL, Silvia PJ, Eddington KM, Sperry SH, Kwapil TR. Conscientiousness and Effort-Related Cardiac Activity in Response to Piece-Rate Cash Incentives. MOTIVATION AND EMOTION 2018; 42:377-385. [PMID: 30220751 DOI: 10.1007/s11031-018-9668-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Although conscientiousness predicts many aspects of motivation, from delay of gratification to higher achievement, its relationship to responses to monetary incentives is surprisingly inconsistent. Several studies have found null or relationships between conscientiousness and behavioral performance in piece-rate, pay-for-performance tasks, in which people earn money for each unit of work completed. In the present study, we examined the role of conscientiousness in effort-related cardiac activity and behavioral performance during a pay-for-performance task. People worked on a self-paced, piece-rate cognitive task in which they earned 1 cent or 5 cents, manipulated within-person, for each correct response. Conscientiousness predicted greater physiological effort (i.e., shorter pre-ejection period [PEP] reactivity) as incentives increased but had no effect on behavioral performance. The findings suggest that conscientiousness is significantly related to effort for piece-rate tasks, and they reinforce a core idea in motivational intensity theory: effort, performance, and persistence are distinct outcomes that often diverge, so drawing conclusions about effort from performance can be complex.
Collapse
|
5
|
Salvi P, Grillo A, Tan I, Simon G, Salvi L, Gao L, Rovina M, Butlin M, Yang Y, Meneghin E, Meng L, Faini A, Barin E, Pini A, Carretta R, Huo Y, Avolio A, Parati G. Systolic time intervals assessed from analysis of the carotid pressure waveform. Physiol Meas 2018; 39:084002. [PMID: 30033934 DOI: 10.1088/1361-6579/aad51b] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The timing of mechanical cardiac events is usually evaluated by conventional echocardiography as an index of cardiac systolic function and predictor of cardiovascular outcomes. We aimed to measure the systolic time intervals, namely the isovolumetric contraction time (ICT) and pre-ejection period (PEP), by arterial tonometry. APPROACH Sixty-two healthy volunteers (age 47 ± 17 years) and 42 patients with heart failure and reduced ejection fraction were enrolled (age 66 ± 14 years). Pulse waves were recorded at the carotid artery by arterial tonometry together with simultaneous aortic transvalvular flow by Doppler-echocardiography, synchronized by electrocardiographic gating. The ICT was determined from the time delay between the electrical R wave and the carotid pressure waveform, after adjustment for the pulse transit time from the aortic valve to the carotid artery site, estimated by an algorithm based on the carotid-femoral pulse wave velocity. The PEP was evaluated by adding the electrical QR duration to the ICT. MAIN RESULTS The ICT derived from carotid pulse wave analysis was closely related to that measured by echocardiography (r = 0.90, p < 0.0001), with homogeneous distribution in Bland-Altman analysis (mean difference and 95% confidence interval = 0.2 from -14.2 to 14.5 ms). ICT and PEP were higher in cardiac patients than in healthy volunteers (p < 0.0001). The ratio between PEP and left ventricular ejection time was related to the ejection fraction measured with echocardiography (r = 0.555, p < 0.0001). SIGNIFICANCE The timing of electro-mechanical cardiac events can be reliably obtained from the carotid pulse waveform and carotid-femoral PWV, evaluated using arterial tonometry. Systolic time intervals assessed with this approach showed good agreement with measurements performed with conventional echocardiography and may represent a promising additional application of arterial tonometry.
Collapse
Affiliation(s)
- Paolo Salvi
- Istituto Auxologico Italiano, IRCCS, Department of Cardiovascular, Neural and Metabolic Sciences, Milan, Italy
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
A mini-fluid challenge of 150 mL predicts fluid responsiveness using Modelflow R pulse contour cardiac output directly after cardiac surgery. J Clin Anesth 2018; 46:17-22. [DOI: 10.1016/j.jclinane.2017.12.022] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 12/01/2017] [Accepted: 12/21/2017] [Indexed: 01/20/2023]
|
7
|
|
8
|
Toscani L, Aya HD, Antonakaki D, Bastoni D, Watson X, Arulkumaran N, Rhodes A, Cecconi M. What is the impact of the fluid challenge technique on diagnosis of fluid responsiveness? A systematic review and meta-analysis. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2017; 21:207. [PMID: 28774325 PMCID: PMC5543539 DOI: 10.1186/s13054-017-1796-9] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2017] [Accepted: 07/12/2017] [Indexed: 12/21/2022]
Abstract
Background The fluid challenge is considered the gold standard for diagnosis of fluid responsiveness. The objective of this study was to describe the fluid challenge techniques reported in fluid responsiveness studies and to assess the difference in the proportion of ‘responders,’ (PR) depending on the type of fluid, volume, duration of infusion and timing of assessment. Methods Searches of MEDLINE and Embase were performed for studies using the fluid challenge as a test of cardiac preload with a description of the technique, a reported definition of fluid responsiveness and PR. The primary outcome was the mean PR, depending on volume of fluid, type of fluids, rate of infusion and time of assessment. Results A total of 85 studies (3601 patients) were included in the analysis. The PR were 54.4% (95% CI 46.9–62.7) where <500 ml was administered, 57.2% (95% CI 52.9–61.0) where 500 ml was administered and 60.5% (95% CI 35.9–79.2) where >500 ml was administered (p = 0.71). The PR was not affected by type of fluid. The PR was similar among patients administered a fluid challenge for <15 minutes (59.2%, 95% CI 54.2–64.1) and for 15–30 minutes (57.7%, 95% CI 52.4–62.4, p = 1). Where the infusion time was ≥30 minutes, there was a lower PR of 49.9% (95% CI 45.6–54, p = 0.04). Response was assessed at the end of fluid challenge, between 1 and 10 minutes, and >10 minutes after the fluid challenge. The proportions of responders were 53.9%, 57.7% and 52.3%, respectively (p = 0.47). Conclusions The PR decreases with a long infusion time. A standard technique for fluid challenge is desirable. Electronic supplementary material The online version of this article (doi:10.1186/s13054-017-1796-9) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Laura Toscani
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK.,Cristo Re Hospital, Via delle Calasanziane 25, 00167, Rome, Italy
| | - Hollmann D Aya
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK. .,Anaesthetic Department, East Surrey Hospital, Surrey & Sussex Healthcare Trust, Canada Avenue, Redhill, Surrey, RH1 5 RH, UK.
| | - Dimitra Antonakaki
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK.,Cardiology Department, Broomfield Hospital, Mid-Essex Healthcare Trust, Court Road, Broomfield, Chelmsford, CM1 7ET, UK
| | - Davide Bastoni
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK.,Dipartimento di Medicina Sperimentale, Azienda Ospedaliero-Universitaria di Parma, Via Gramsci 14, 43126, Parma, Italy
| | - Ximena Watson
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK
| | - Nish Arulkumaran
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK
| | - Andrew Rhodes
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK
| | - Maurizio Cecconi
- General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK
| |
Collapse
|
9
|
Renal systolic time intervals derived from intra-renal artery Doppler as a novel predictor of adverse cardiac outcomes. Sci Rep 2017; 7:43825. [PMID: 28266644 PMCID: PMC5339860 DOI: 10.1038/srep43825] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Accepted: 01/25/2017] [Indexed: 12/28/2022] Open
Abstract
The aim of this study was to evaluate the use of renal systolic time intervals measured by electrocardiographic gated Doppler ultrasonography for predicting adverse cardiac events. This longitudinal observation study enrolled 205 patients. Renal systolic time intervals, including pre-ejection period (PEP) and ejection time (ET), and ratio of renal PEP to ET, were measured by electrocardiographic gated Doppler ultrasound. The 14 adverse cardiac events identified in this population included 9 cardiac deaths and 5 hospitalizations for heart failure during an average follow up of 30.9 months (25th-75th percentile: 30-33 months). Renal PEP (hazard ratio = 1.023, P = 0.001), renal ET (hazard ratio = 0.975, P = 0.001) and renal PEP/ET (per 0.01 unit increase, hazard ratio = 1.060, P < 0.001) were associated with poor cardiac outcomes. The addition of renal PEP/ET to a Cox model containing important clinical variables and renal resistive index further improved the value in predicting adverse cardiac events (Chi-square increase, 9.996; P = 0.002). This study showed that parameters of intra-renal hemodynamics were potential predictors of adverse cardiac outcomes. However, the generalizability of these indicators need to be investigated in future large-scale studies.
Collapse
|
10
|
Systolic Time Intervals and New Measurement Methods. Cardiovasc Eng Technol 2016; 7:118-25. [DOI: 10.1007/s13239-016-0262-1] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2015] [Accepted: 03/29/2016] [Indexed: 10/22/2022]
|