1
|
Mokryk I, Nechai I, Stetsyuk I, Malova N, Demyanchuk V, Todurov B. Complete Aortic Valve Reconstruction with Autologous Pericardium: Analysis of Mid-Term Results of Single-Center Experience with AVNeo Procedure. Ann Thorac Cardiovasc Surg 2024; 30:24-00067. [PMID: 39198196 PMCID: PMC11357901 DOI: 10.5761/atcs.oa.24-00067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Accepted: 07/17/2024] [Indexed: 09/01/2024] Open
Abstract
PURPOSE Aortic valve neocuspidization (AVNeo) is a relatively recent advancement in surgical AV replacement. Data on its performance beyond the short term are limited. We assessed the mid-term outcomes in patients undergoing AVNeo, focusing on feasibility, perioperative details, and its role in AV pathology treatment. METHODS Sixty-five consecutive patients underwent AVNeo between December 2016 and February 2018. Clinical data were prospectively collected and retrospectively analyzed. Tricuspid reconstruction with autologous pericardium was performed in all cases. Echocardiographic follow-up was conducted post-discharge, at 6 and 12 months, and annually thereafter. RESULTS The mean age was 62.6 ± 18.7 years. AVNeo was feasible in all cases. Concomitant procedures were performed in 43 (66.2%) patients. Mean bypass and cross-clamp times were 119.2 ± 30.3 and 87.1 ± 22.9 minutes, respectively. Postoperative transvalvular hemodynamics was excellent. There was one (1.5%) in-hospital death. Follow-up (mean 66.72 ± 12.77 months) was complete in 58 patients (89.2%). There were no detected valve-related or thromboembolic events. Transvalvular hemodynamic parameters were stable during the observation period: peak pressure gradient at discharge and follow-up was 15.3 ± 4.6 mmHg and 15.01 ± 6.3 mmHg, respectively (ρ = 0.346). CONCLUSIONS AVNeo demonstrated the feasibility and favorable mid-term outcomes. Studies with longer-term observation are warranted to evaluate its durability.
Collapse
Affiliation(s)
- Igor Mokryk
- Department of Adult Cardiac Surgery, Heart Institute Ministry of Healthcare of Ukraine, Kyiv, Ukraine
| | - Illia Nechai
- Department of Adult Cardiac Surgery, Heart Institute Ministry of Healthcare of Ukraine, Kyiv, Ukraine
| | - Ihor Stetsyuk
- Department of Adult Cardiac Surgery, Heart Institute Ministry of Healthcare of Ukraine, Kyiv, Ukraine
| | - Nataliia Malova
- Department of Adult Cardiac Surgery, Heart Institute Ministry of Healthcare of Ukraine, Kyiv, Ukraine
| | - Vitaly Demyanchuk
- Department of Adult Cardiac Surgery, Heart Institute Ministry of Healthcare of Ukraine, Kyiv, Ukraine
| | - Borys Todurov
- Department of Adult Cardiac Surgery, Heart Institute Ministry of Healthcare of Ukraine, Kyiv, Ukraine
| |
Collapse
|
2
|
Gonzalez-Barbeito M, Arribas Leal JM, Jimenez Alfaro L, Calderon Romero MP, Carnero M, Sarralde JA, Vazquez A, Canovas Lopez SJ, Aldamiz-Echevarria G, Gutierrez F, Fernandez AL, Bautista-Hernandez V. Outcomes of rapid deployment aortic valve replacement with concomitant cardiac procedures. J Thorac Dis 2023; 15:5605-5612. [PMID: 37969290 PMCID: PMC10636483 DOI: 10.21037/jtd-23-191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 09/08/2023] [Indexed: 11/17/2023]
Abstract
Background Rapid deployment aortic valve replacement (RD-AVR) has been recently introduced with encouraging results. Outcomes of isolated RD-AVR include good hemodynamic profile, facilitation of minimally invasive techniques, and reduction of surgical times. However, role of this prosthesis in concomitant surgery is not well known. Methods In 2016, we formed a registry to monitor the introduction of this prosthesis, RApid Deployment Aortic Replacement (RADAR). We aim to report mid-term outcomes focusing on patients who had RD-AVR combined with other surgical procedures. Results Between July 2012 and February 2021, 370 patients were included in this registry (mean age, 75.8±8.0 years; 64.32% male; mean EuroSCORE II, 3.5±2.8). Of these, 128 (34.59%) had concomitant procedures including myocardial revascularization surgery in 69 patients (53.91%), surgery on the ascending aorta in 34 (26.56%), and procedures on other valves in 10 patients (7.81%). There were no significant differences between the isolated AVR and concomitant AVR groups in postoperative complications, in-hospital mortality (4.72% vs. 3.32%, P=0.524), or hemodynamic behavior of these prostheses. Three-year survival was 83.73% and 89.89% in the isolated and concomitant AVR group respectively. There was no difference in survival between the two groups (log-rank test, P=0.4124). Conclusions Our results support the safety and efficacy of the Edwards INTUITY valve system even in complex aortic valve disease with additional cardiac procedures. RD-AVR could become a useful tool for concomitant surgeries where surgical times are expected to be prolonged.
Collapse
Affiliation(s)
| | - Jose M. Arribas Leal
- Department of Cardiac Surgery, Hospital Clínico Universitario Virgen de la Arrixaca, Instituto Murciano de Investigaciones Biomédicas, Murcia, Spain
| | - Luis Jimenez Alfaro
- Department of Cardiac Surgery, Hospital Universitario de Navarra, Pamplona, Spain
| | - Maria P. Calderon Romero
- Department of Cardiac Surgery, Fundación Jiménez Díaz/Clínica Nuestra Señora de la Concepción, Madrid, Spain
| | - Manuel Carnero
- Department of Cardiac Surgery, Hospital Clínico de San Carlos, Madrid, Spain
| | - Jose A. Sarralde
- Department of Cardiac Surgery, Hospital Universitario Marqués de Valdecilla, Santander, Spain
| | - Alejandro Vazquez
- Department of Cardiac Surgery, Hospital Universitario y Politécnico La Fe, Valencia, Spain
| | - Sergio J. Canovas Lopez
- Department of Cardiac Surgery, Hospital Clínico Universitario Virgen de la Arrixaca, Instituto Murciano de Investigaciones Biomédicas, Murcia, Spain
| | - Gonzalo Aldamiz-Echevarria
- Department of Cardiac Surgery, Fundación Jiménez Díaz/Clínica Nuestra Señora de la Concepción, Madrid, Spain
| | - Francisco Gutierrez
- Department of Cardiac Surgery, Hospital Universitario Marqués de Valdecilla, Santander, Spain
| | - Angel L. Fernandez
- Department of Cardiac Surgery, Hospital Clínico Universitario de Santiago, Universidad de Santiago de Compostela, Galicia, Spain
| | - Victor Bautista-Hernandez
- William E. De Bakey Department of Surgery, Baylor College of Medicine/Christus Health Santa Rosa, San Antonio, TX, USA
| |
Collapse
|
3
|
Schlömicher M, Useini D, Haldenwang PL, Naraghi H, Moustafine V, Bechtel M, Strauch JT. Outcomes in Patients with Left Bundle Branch Block after Rapid Deployment Aortic Valve Replacement. Thorac Cardiovasc Surg 2023; 71:528-534. [PMID: 35108737 DOI: 10.1055/s-0042-1742361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
OBJECTIVES Increased rates of postoperative left bundle branch block (LBBB) and permanent pacemaker implantation (PPI) frequently occur after implantation of rapid deployment valves. The impact of LBBB on follow-up outcomes remains controversial. So far, no data regarding long-term outcomes exist. AIM The aim of this study was to analyze the impact of LBBB on postoperative outcomes after rapid deployment aortic valve replacement (RDAVR). METHODS A total of 620 consecutive patients without preexisting LBBB or PPI who underwent rapid deployment AVR between March 2012 and September 2019 were included. New-onset LBBB was defined as any new LBBB that persisted at hospital discharge. The median follow-up time for clinical data was 1.7 years post-RDAVR. RESULTS At discharge, new-onset LBBB was seen in 109 patients (17.5%). There were no differences between the LBBB groups and no-LBBB groups regarding baseline characteristics. At a median follow-up of 1.7 years, no difference was found between LBBB groups and no-LBBB groups concerning all-cause mortality (12.8 vs. 11.7%; hazard ratio [HR]: 1.08; 95% confidence interval [CI]: 0.74-1.53; p = 0.54). Nevertheless, new-onset LBBB was associated with significant higher pacemaker implantation rates at follow-up (10.1 vs. 6.3%; HR: 3.58; 95% CI: 1.89-6.81 p < 0.001). CONCLUSION After a median follow-up of 1.7 years, new-onset LBBB was not associated with increased mortality. Nevertheless, higher pacemaker implantation rates were observed in patients with new-onset LBBB after RDAVR.
Collapse
Affiliation(s)
- Markus Schlömicher
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Dritan Useini
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Peter Lukas Haldenwang
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Hamid Naraghi
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Vadim Moustafine
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Matthias Bechtel
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Justus Thomas Strauch
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| |
Collapse
|
4
|
Yun T, Kim KH, Sohn SH, Kang Y, Kim JS, Choi JW. Rapid-Deployment Aortic Valve Replacement in a Real-World All-Comers Population. Thorac Cardiovasc Surg 2023; 71:511-518. [PMID: 36216332 DOI: 10.1055/s-0042-1757241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
BACKGROUND This study was conducted to evaluate the mid-term outcomes of rapid-deployment aortic valve replacement (AVR) using Edwards Intuity. METHODS A total of 215 patients underwent rapid-deployment AVR using Edwards Intuity at our institution. The median follow-up duration was 22 months (interquartile range, 8-36). Primary outcomes were overall survival, cumulative incidence of cardiac death, and major adverse cardiac events. Secondary outcomes were early and 1-year hemodynamic performances of the bioprosthetic valve. RESULTS The mean age was 68.6 ± 10.5 years, and EuroSCORE II was 3.09 ± 4.5. The study population included 113 patients (52.6%) with bicuspid valves (24 patients with type 0 bicuspid valves), 20 patients (9.3%) with pure aortic regurgitation, and 3 patients (1.4%) with infective endocarditis. Isolated AVR was performed in 70 patients (32.4%) and concomitant procedures were performed in 146 patients (67.6%), including aorta surgery (42.3%) and mitral valve procedure (22.3%). Operative mortality was 2.8%. Complete atrioventricular block occurred in 12 patients, but most of them were transient and only 3 patients received permanent pacemaker implantation before discharge. Overall survival at 3 years was 92.3%. Early hemodynamic data showed mean pressure gradients of 15.5 ± 5.0 and 12.7 ± 4.2 mm Hg in the 19 and 21 mm valve, respectively. One-year hemodynamics were also excellent with mean pressure gradients of 14.7 ± 5.3 and 10.7 ± 3.6 mm Hg in the 19 and 21 mm valve, respectively. CONCLUSION Based on a real-world all-comers population, rapid-deployment AVR using Edwards Intuity could be performed for various indications, including bicuspid valve, pure aortic regurgitation, and infective endocarditis, and the clinical and hemodynamic outcomes were excellent.
Collapse
Affiliation(s)
- Taeyoung Yun
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Kyung Hwan Kim
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Suk Ho Sohn
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Yoonjin Kang
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Ji Seong Kim
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Jae Woong Choi
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
5
|
Sohn SH, Kim KH, Kang Y, Kim JS, Choi JW, Hwang HY. Rapid deployment versus its conventional counterpart in aortic valve replacement: comparison of early hemodynamic outcomes. J Thorac Dis 2023; 15:3673-3684. [PMID: 37559609 PMCID: PMC10407519 DOI: 10.21037/jtd-23-318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Accepted: 06/09/2023] [Indexed: 08/11/2023]
Abstract
BACKGROUND Edwards Intuity is designed for rapid deployment based on the structure of Magna Ease. This study was conducted to compare early hemodynamic performance between the two valves. METHODS Patients who underwent aortic valve replacement (AVR) using Edwards Intuity or Carpentier-Edwards PERIMOUNT Magna Ease in our institution from June 2016 to July 2021 were enrolled. Intuity valve was used in 215 patients, and Magna Ease valve was used in 198 patients, respectively. Early postoperative echocardiographic data were available in 99.0% (409/413) of the patients. The transvalvular mean pressure gradient, effective orifice area, and effective orifice area index were compared between the valves stratified by prosthesis size. RESULTS There were no differences in the proportion of female patients or body surface area between the groups. Mean pressure gradient on early postoperative echocardiography was significantly lower in Intuity valve than Magna Ease valve for 19, 21, 23, and 25 mm valves (15.5±5.0 vs. 20.8±9.1 mmHg, P=0.004; 12.7±4.2 vs. 15.6±5.3 mmHg, P=0.001; 11.5±3.3 vs. 13.4±5.8 mmHg, P=0.034; and 9.9±3.1 vs. 12.3±4.0 mmHg, P=0.029; respectively). Effective orifice area was larger in Intuity valve than Magna Ease valve for 19 mm valve (1.45±0.38 vs. 1.19±0.28 cm2, P=0.002), and effective orifice area index was also larger in Intuity valve than Magna Ease valve for 19 mm valve (0.96±0.26 vs. 0.80±0.20 cm2/m2, P=0.005). Early clinical outcomes, including operative mortality and postoperative complications, demonstrated no significant differences between the groups. CONCLUSIONS Edwards Intuity demonstrated superior early hemodynamic performance compared with Magna Ease in a size-by-size comparison, and this superiority was more definite for small prostheses.
Collapse
|
6
|
Laufer G. The 10 Commandments of Rapid Deployment Intuity Valve Implantation. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2023; 18:316-319. [PMID: 37615164 DOI: 10.1177/15569845231191770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Affiliation(s)
- Günther Laufer
- Department of Cardiac Surgery, Medical University of Vienna, Austria
| |
Collapse
|
7
|
Sakata T, De La Pena C, Ohira S. Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special Considerations. Vasc Health Risk Manag 2023; 19:169-180. [PMID: 37016696 PMCID: PMC10066891 DOI: 10.2147/vhrm.s374410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Accepted: 03/07/2023] [Indexed: 03/30/2023] Open
Abstract
Sutureless or rapid deployment valves in the setting of aortic valve replacement (AVR) is an emerging surgical technique using the transcatheter valve technology, which may lead to reduction in cross-clamp time and potentially better hemodynamics compared to a stented bioprosthetic valve. The absence of subannular pledgets results to excellent hemodynamic performance with reduced turbulent flow and larger effective orifice area. However, complications from both surgical and transcatheter AVR may still occur and impact survival. The incidence of paravalvular leakage and permanent pacemaker implantation are not low. Although technical modifications can improve these outcomes, there is a learning curve effect. Therefore, technical and anatomical considerations as well as better patient selection are paramount for better outcomes. In this review, we discuss the use of sutureless or rapid deployment valves in setting of (1) complex procedures, (2) minimally invasive AVR, and (3) small aortic annulus. The advantage of sutureless or rapid deployment valves in terms of mortality remains to be clarified; therefore, it is necessary to accumulate long-term outcomes in an appropriate patient cohort.
Collapse
Affiliation(s)
- Tomoki Sakata
- Cardiovascular Research Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Corazon De La Pena
- Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, Valhalla, NY, USA
| | - Suguru Ohira
- Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, Valhalla, NY, USA
- Correspondence: Suguru Ohira, Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, 100 Woods Road, Macy Pavilion, Valhalla, NY, 10595, USA, Tel +1 404 234 5433, Email
| |
Collapse
|
8
|
Dokollari A, Torregrossa G, Sicouri S, Veshti A, Margaryan R, Cameli M, Mandoli GE, Maccherini M, Montesi G, Cabrucci F, Coku L, Arora R, Li QR, Bonacchi M, Gelsomino S. Pearls, pitfalls, and surgical indications of the Intuity TM heart valve: A rapid deployment bioprosthesis. A systematic review of the literature. J Card Surg 2022; 37:5411-5417. [PMID: 36403259 DOI: 10.1111/jocs.17231] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 10/27/2022] [Accepted: 10/31/2022] [Indexed: 11/21/2022]
Abstract
OBJECTIVES To highlight short- and long-term clinical outcomes of the Intuity TM rapid deployment prosthesis for surgical aortic valve replacement. METHODS We reviewed on PubMed/MEDLINE, Embase, SciELO, LILACS, CCTR/CENTRAL, and Google Scholar for clinical trials, retrospective clinical studies, meta-analysis, and gray literature. RESULTS Fourty-five clinical studies with 12.714 patients were included in the analysis. Thirty-day mortality ranged from 3.8% for Intuity and 3.9% for transcatheter aortic valve replacement (TAVR). The incidence of paravalvular leak (PVL) (Intuity 0% and TAVR 2.17%), permanent pacemaker implantation (Intuity 11.11% and TAVR 12.5%), stroke (Intuity 2.2% and TAVR 2.6%), myocardial infarction (MI) (Intuity 0% and TAVR 1%), were all higher in the TAVR group. Compared to other sutured bioprosthesis (SB), mortality ranged from 0% to 3.9% for Intuity and 0%-6.9% for SB. Long-term cardiac mortality ranged from 0.9% to 1.55% for Intuity and 1.4%-3.3% for the Perceval valve. The incidence of PVL (Intuity 0.24%-0.7% and Perceval 0%-1%), endocarditis (Intuity 0.2%-0.7% and Perceval 1.6%-6.6%), stroke (Intuity 0.36%-1.4% and Perceval 0%-0.8%), MI (Intuity 0.07%-0.26%), and SVD (Intuity 0.12%-0.7% and Perceval 0%) were comparable. Compared to standard full sternotomy (SFS), minimally invasive surgery (MINV) mortality ranged from 0% to 4.3% for MINV and 0%-2.1% for SFS. Hospital costs outcomes ranged from $37,187-$44,368 for the Intuity, $69,389 for TAVR, and $13,543 for SB. Intuity short-term mortality ranged between 0.9% and 12.4% while long-term mortality ranged between 2.6% and 20%. CONCLUSIONS This manuscript provides a 360° overview of the current rapid deployments, sutureless, and TAVR prosthesis.
Collapse
Affiliation(s)
- Aleksander Dokollari
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA.,Department of Cardiothoracic Surgery, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Gianluca Torregrossa
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA.,Department of Cardiothoracic Surgery, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Serge Sicouri
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Altin Veshti
- Department of Cardiac Surgery, Mother Teresa Hospital, University of Tirana, Tirana, Albania
| | - Rafik Margaryan
- Department of Adult Cardiac Surgery, G. Pasquinucci Heart Hospital, Fondazione CNR-G. Monasterio, Massa, Italy
| | - Matteo Cameli
- Department of Experimental and Clinical Medicine, Cardiac Surgery Unit, University of Florence, Firenze, Italy
| | - Giulia Elena Mandoli
- Department of Experimental and Clinical Medicine, Cardiac Surgery Unit, University of Florence, Firenze, Italy
| | - Massimo Maccherini
- Department of Experimental and Clinical Medicine, Cardiac Surgery Unit, University of Florence, Firenze, Italy
| | - Gianfranco Montesi
- Department of Experimental and Clinical Medicine, Cardiac Surgery Unit, University of Florence, Firenze, Italy
| | - Francesco Cabrucci
- Department of Cardiac Surgery/Cardiology, University of Siena, Siena, Italy
| | - Lindita Coku
- Department of Cardiac Surgery, Appalachian Regional Health, University of Kentucky, Hazard, Kentucky, USA
| | - Rakesh Arora
- Department of Surgery, Section of Cardiac Surgery, Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Qiao Ri Li
- 2010 Vision Associates, Toronto, Ontario, Canada
| | - Massimo Bonacchi
- Department of Cardiac Surgery/Cardiology, University of Siena, Siena, Italy
| | - Sandro Gelsomino
- Department of Cardiac Surgery, CARIM Maastricht Medical University, Maastricht, Netherlands
| |
Collapse
|
9
|
Laufer G, Strauch JT, Terp KA, Salinas M, Arribas JM, Massetti M, Andreas M, Young CP. Real-world 6-month outcomes of minimally invasive aortic valve replacement with the EDWARDS INTUITY Elite valve system. Interact Cardiovasc Thorac Surg 2022; 35:6565358. [PMID: 35394527 PMCID: PMC9631962 DOI: 10.1093/icvts/ivac083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 02/18/2021] [Accepted: 04/01/2022] [Indexed: 11/20/2022] Open
Affiliation(s)
- Günther Laufer
- Department of Cardiac Surgery, Medical University of Vienna/Cardiac Surgery , Vienna, Austria
| | - Justus T Strauch
- Department of Cardiothoracic Surgery, University Hospital Bergmannsheil Bochum , Bochum, Germany
| | - Kim A Terp
- Department of Cardiac Surgery, Aarhus University Hospital Skejby , Aarhus, Denmark
| | - Marco Salinas
- Department of Cardiac Surgery, Ospedale Del Cuore G.Pasquinucci , Massa, Italy
| | - Jose M Arribas
- Department of Cardiac Surgery, Hospital Clínico Universitario Virgen de la Arrixaca , El Palmar, Murcia, Spain
| | - Massimo Massetti
- Department of Cardiovascular Sciences, Catholic University of Sacred Heart—Rome , Rome, Italy
| | - Martin Andreas
- Department of Cardiac Surgery, Medical University of Vienna , Vienna, Austria
| | | |
Collapse
|
10
|
Amabile A, Krane M, Dufendach K, Baird CW, Ganjoo N, Eckstein FS, Albertini A, Gruber PJ, Mumtaz MA, Bacha EA, Benedetto U, Chikwe J, Geirsson A, Holfeld J, Iida Y, Lange R, Morell VO, Chu D. Standardized Aortic Valve Neocuspidization for Treatment of Aortic Valve Diseases. Ann Thorac Surg 2022; 114:1108-1117. [PMID: 35439450 DOI: 10.1016/j.athoracsur.2022.03.067] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 03/04/2022] [Accepted: 03/20/2022] [Indexed: 12/31/2022]
Abstract
BACKGROUND Aortic valve replacement is the traditional surgical treatment for aortic valve diseases, yet standardized aortic valve neocuspidization (AVNeo) is a promising alternative that is gaining popularity. The purpose of this article is to review the available published literature of AVNeo using glutaraldehyde-treated autologous pericardium, also known as the Ozaki procedure, including indications, outcomes, potential benefits, and modes of failure for the reconstructed valve. METHODS A comprehensive literature search was performed using keywords related to aortic valve repair, AVNeo, or Ozaki procedure. All articles describing performance of AVNeo were reviewed. RESULTS Reported early mortality after AVNeo varies from 0% to 5.88%. The largest cohort of patients in the literature includes 850 patients with an inhospital mortality rate of 1.88%. Cumulative incidence of aortic valve reoperation was 4.2% in the largest series. Reoperation was uncommon and mainly due to infective endocarditis or degeneration of the reconstructed valve (most commonly due to aortic valve regurgitation, rather than stenosis). CONCLUSIONS Aortic valve neocuspidization is a versatile and standardized alternative to aortic valve replacement with a biological prosthesis. Early to midterm outcomes from a number of centers are excellent and demonstrate the safety and durability of the procedure. Long-term outcomes and clinical trial data are necessary to determine which patients benefit the most from this procedure.
Collapse
Affiliation(s)
- Andrea Amabile
- Division of Cardiac Surgery, Department of Surgery, Yale University School of Medicine, New Haven, Connecticut
| | - Markus Krane
- Division of Cardiac Surgery, Department of Surgery, Yale University School of Medicine, New Haven, Connecticut
| | - Keith Dufendach
- Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania
| | - Christopher W Baird
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts
| | - Nikhil Ganjoo
- Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania
| | - Friedrich S Eckstein
- Department of Cardiac Surgery, University Hospital Basel, University of Basel, Switzerland
| | - Alberto Albertini
- Cardiovascular Surgery Department, Maria Cecilia Hospital GVM Care and Research, Cotignola, Revenna, Italy
| | - Peter J Gruber
- Division of Cardiac, Thoracic, and Vascular Surgery, Section of Pediatric and Congenital Heart Surgery, Columbia University Medical Center/New York-Presbyterian Hospital, New York, New York
| | - Mubashir A Mumtaz
- University of Pittsburgh Medical Center Heart and Vascular Institute, Pittsburgh, Pennsylvania
| | - Emile A Bacha
- Division of Cardiac, Thoracic, and Vascular Surgery, Section of Pediatric and Congenital Heart Surgery, Columbia University Medical Center/New York-Presbyterian Hospital, New York, New York
| | - Umberto Benedetto
- Department of Cardiac Surgery, University Chieti-Pescara, Chieti, Italy
| | - Joanna Chikwe
- Department of Cardiac Surgery, Cedars-Sinai Medical Center, Smidt Heart Institute, Los Angeles, California
| | - Arnar Geirsson
- Division of Cardiac Surgery, Department of Surgery, Yale University School of Medicine, New Haven, Connecticut
| | - Johannes Holfeld
- Department of Cardiac Surgery, Innsbruck Medical University, Innsbruck, Austria
| | - Yasunori Iida
- Department of Cardiovascular Surgery, Saiseikai Yokohamashi Tobu Hospital, Yokohama, Japan
| | - Rüdiger Lange
- Department of Cardiovascular Surgery, German Heart Center, Munich, Germany
| | - Victor O Morell
- Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania; University of Pittsburgh Medical Center Heart and Vascular Institute, Pittsburgh, Pennsylvania
| | - Danny Chu
- Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania; University of Pittsburgh Medical Center Heart and Vascular Institute, Pittsburgh, Pennsylvania.
| |
Collapse
|
11
|
Coti I, Werner P, Kaider A, Mach M, Kocher A, Laufer G, Andreas M. Rapid-deployment aortic valve replacement for patients with bicuspid aortic valve: a single-centre experience. Eur J Cardiothorac Surg 2022; 62:6514631. [DOI: 10.1093/ejcts/ezac017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 10/18/2021] [Accepted: 01/07/2022] [Indexed: 11/14/2022] Open
Abstract
Abstract
OBJECTIVES
The benefit of rapid-deployment aortic valve replacement (RD-AVR) in patients with a bicuspid aortic valve (BAV) is controversial due to aortic root asymmetry and potential increased risk for valve dislocation and paravalvular leak. This study aimed to analyse the outcomes of surgical aortic valve replacement with a rapid-deployment bioprosthesis in patients with a BAV.
METHODS
Between May 2010 and December 2020, all consecutive patients who underwent RD-AVR at the Medical University of Vienna were included in our institutional database. Assessment of preoperative characteristics, operative outcomes, long-term survival and clinical events was performed. The outcomes of patients presenting with a native BAV were compared with a control group of patients with native tricuspid valve (TAV); reoperative aortic valve replacements were excluded.
RESULTS
Out of 816 patients, who underwent RD-AVR at our institution, 107 patients with a BAV, mean age 68 (standard deviation: 8) years, were compared with a control group of 690 patients with a TAV, mean age 74 (standard deviation: 7) years; patients presenting with a BAV were significantly younger than patients with a TAV (P < 0.001). Concomitant procedures were performed in 44 (41.1%) patients in the BAV group and in 339 (49.1%) patients in the TAV group (P = 0.123); surgery of the ascending aorta was necessary in 24 (22.4%) in the BAV group, compared with 29 (4.2%) in the control group (P < 0.001). The 5-year cumulative incidence of moderate-to-severe paravalvular regurgitation in the BAV group was 10.7% [95% confidence interval (CI): 4.2–20.7%] and 3.9% (95% CI: 2.4–6.1%) in the TAV group (P = 0.057). Reoperation with valve explantation due to non-structural valve dysfunction at 5 years was 2.8% (95% CI: 0.5–8.8%) in the BAV group, compared to 1.9% (95% CI: 1.0–3.2%) in the TAV cohort (P = 0.89). The overall long-term survival rate in the BAV group was 92% (95% CI: 81–97%) at 5 years and 88% (95% CI: 73–95%), at 10 years, significantly better compared to the TAV group (log-rank test P = 0.002).
CONCLUSIONS
RD-AVR can be performed in patients with a BAV with convincingly medical outcomes. However, a trend to increased frequency of moderate–severe paravalvular regurgitation was observed at long-term follow-up. Consequently, a different surgical approach, compared to tricuspid valves, with distinctly specific technical- and anatomical considerations and requirements, is recommended.
Collapse
Affiliation(s)
- Iuliana Coti
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Paul Werner
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Alexandra Kaider
- Center for Medical Statistics, Informatics, and Intelligent Systems, Medical University of Vienna, Vienna, Austria
| | - Markus Mach
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Alfred Kocher
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Guenther Laufer
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Martin Andreas
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
12
|
Hori D, Yamamoto T, Kusadokoro S, Fujimori T, Mieno MN, Kimura N, Yamaguchi A. Evaluation of oversizing in association with conduction disorder after implantation of a rapid deployment valve. J Artif Organs 2021; 25:238-244. [PMID: 34727259 DOI: 10.1007/s10047-021-01301-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Accepted: 10/21/2021] [Indexed: 10/19/2022]
Abstract
Rapid deployment valve has expanded surgical indication for high-risk patients with aortic stenosis despite its accommodated risk for conduction disorder (CD). The purpose of this study was to evaluate the degree of oversizing in association with postoperative CD. During June 2019 to September 2021, 25 patients underwent aortic valve replacement with Edwards INTUITY. Device size selection was evaluated intraoperatively using provided sizers. Oversizing was evaluated retrospectively by measuring the difference of the dimension of the annulus and left ventricular outflow tract (LVOT) compared to the dimensions of the device used by preoperative-computed tomography. Although there was no incidence of pacemaker implantation, seven patients (28.0%) experienced CD after surgery. There was no difference in device area and annulus area (CD: - 37 ± 22.7 mm2 vs. no CD: - 56 ± 63.6 mm2, p = 0.47), and device circumference and annulus circumference (CD: - 4.4 ± 2.77 mm vs. no CD: - 6.9 ± 5.60 mm, p = 0.26) in patients with and without CD. However, there was a significant difference in area of the device skirt and sub-annular area at the LVOT (CD: 114 ± 28.4 mm2 vs. no CD: - 8 ± 80.0 mm2, p < 0.001), and circumference of device skirt and the LVOT (CD: 3.9 ± 2.08 mm vs. no CD: - 4.6 ± 5.24 mm, p < 0.001) between the two groups. Receiver operating characteristic curve analysis showed that an area difference of 77.7 mm2 and circumference difference of 0.91 mm at LVOT were associated with postoperative CD with specificities of 0.83, 0.78 and sensitivity of 1.0, 1.0, respectively. Preoperative measurement of the LVOT may be useful in evaluating the risk of postoperative CD in patients receiving rapid deployment valve.
Collapse
Affiliation(s)
- Daijiro Hori
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan.
| | - Takahiro Yamamoto
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan
| | - Sho Kusadokoro
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan
| | - Tomonari Fujimori
- Department of Medical Informatics, Center for Information, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke-shi, Tochigi, 329-0498, Japan
| | - Makiko Naka Mieno
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan
| | - Naoyuki Kimura
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan
| | - Atsushi Yamaguchi
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan
| |
Collapse
|
13
|
Woo HS, Hwang HY, Kim HJ, Kim JB, Lee S, Lim C, Chang BC, Lee NR, Suh Y, Choi JW. Changes in the Prosthesis Types Used for Aortic Valve Replacement after the Introduction of Sutureless and Rapid Deployment Valves in Korea: A Nationwide Population-Based Cohort Study. J Chest Surg 2021; 54:369-376. [PMID: 34493693 PMCID: PMC8548199 DOI: 10.5090/jcs.21.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 06/26/2021] [Accepted: 07/14/2021] [Indexed: 11/16/2022] Open
Abstract
Background Sutureless and rapid deployment valves for aortic valve replacement (AVR) were introduced in Korea in December 2016. This study evaluated changing trends in the prosthetic valves used for AVR in Korea after the introduction of sutureless and rapid deployment valves. Methods From December 2016 to December 2018, 4,899 patients underwent AVR in Korea. After applying the exclusion criteria, 4,872 patients were analyzed to determine changes in the type of prosthetic valve used for AVR. The study period was divided into 5 groups corresponding to 5-month intervals. Results The total number of AVR cases was 194.88±28.78 per month during the study period. Mechanical valves were used in approximately 27% to 33% of cases, and the proportion of mechanical valve use showed a tendency to decrease, with marginal significance overall (p=0.078) and significant decreases in patients less than 60 years of age and in men (p=0.013 and p=0.023, respectively). The use of sutureless valves increased from 13.4% to 25.8% of cases (p<0.001), especially in elderly patients (>70 years) and those requiring concomitant surgery. In a comparison between sutureless and rapid deployment valves, the use of Perceval S valves (a type of sutureless valve), gradually increased (p<0.001). Conclusion After the introduction of sutureless and rapid deployment valves in Korea, the rate of use of these new valves remarkably increased, especially in elderly patients and those requiring concomitant surgery. Further studies should investigate the clinical outcomes of these new prostheses.
Collapse
Affiliation(s)
- Hyeok Sang Woo
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul, Korea
| | - Ho Young Hwang
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul, Korea
| | - Ho Jin Kim
- Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Joon Bum Kim
- Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Sak Lee
- Department of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Seoul, Korea
| | - Cheong Lim
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea
| | - Byung-Cheul Chang
- Department of Thoracic and Cardiovascular Surgery, CHA Bundang Medical Center, CHA University, Seongnam, Korea
| | - Na Rae Lee
- National Evidence-based Healthcare Collaborating Agency, Seoul, Korea
| | - Youshin Suh
- National Evidence-based Healthcare Collaborating Agency, Seoul, Korea
| | - Jae Woong Choi
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul, Korea
| |
Collapse
|
14
|
Wiedemann D, Laufer G, Coti I, Mahr S, Scherzer S, Haberl T, Kocher A, Andreas M. Anterior Right Thoracotomy for Rapid-Deployment Aortic Valve Replacement. Ann Thorac Surg 2021; 112:564-571. [DOI: 10.1016/j.athoracsur.2020.09.023] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 09/13/2020] [Accepted: 09/16/2020] [Indexed: 11/25/2022]
|
15
|
Coti I, Maierhofer U, Rath C, Werner P, Loewe C, Kocher A, Laufer G, Andreas M. Effect of conventional and rapid-deployment aortic valve replacement on the distance from the aortic annulus to coronary arteries. Interact Cardiovasc Thorac Surg 2021; 32:196-203. [PMID: 33236042 DOI: 10.1093/icvts/ivaa247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 08/25/2020] [Accepted: 09/27/2020] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES This study aimed to compare the effect of surgical aortic valve replacement (SAVR) on coronary height in patients undergoing SAVR with rapid-deployment or SAVR with several standard sutured bioprostheses. This study may identify patients at higher risk of coronary obstruction during valve-in-valve procedures. METHODS We analysed 112 patients [mean age 71 (9 SD) years] who underwent SAVR with either a rapid-deployment aortic bioprosthesis (EDWARDS INTUITY Elite Valve) or other standard sutured biological valves. The coronary heights were assessed by computed tomography scan with the Philips 3D HeartNavigator system. RESULTS Two groups of patients were analysed: 51 (45.5%) patients implanted with an RD-AVR, which is a supra-annular valve that requires 3 anchoring sutures without the use of pledgets, and 61 (54.5%) patients implanted with a conventional supra-annular sutured bioprosthesis. The mean right and left coronary artery-to-annulus (RCAA and LCAA) heights at baseline were 16.9 (4.6 SD) and 14.2 (4.0 SD) mm in the standard sutured group and 16.3 (3.5 SD) and 12.8 (2.9 SD) mm in the RD-AVR group, respectively; a significantly shorter distance was observed for the left coronary artery in the rapid-deployment group (P = 0.420 for RCAA height and P = 0.044 for LCAA). Postoperatively, the mean RCAA and LCAA heights were significantly decreased in both groups compared to baseline. A mean of 11.5 (4.8 SD) mm for the RCAA and 7.9 (4.3 SD) mm for the LCAA in the standard sutured group as well as 14.4 (3.9 SD) mm for the RCAA and 9.0 (3.1 SD) mm for the LCAA in the RD-AVR group were observed (P < 0.001 for RCAA and LCAA in both the sutured and rapid-deployment groups). Despite the significant difference in the mean distance from the left coronary artery to annulus between the groups at baseline, the postoperative mean distance of the LCAA to the sewing ring was still higher in the RD-AVR group. CONCLUSIONS A significantly shorter coronary artery-to-aortic annulus distance for both the right and left main coronary arteries was observed after AVR with different conventional sutured supra-annular bioprostheses compared to AVR with rapid-deployment valves. These findings might be relevant for bioprosthesis selection, especially for young patients.
Collapse
Affiliation(s)
- Iuliana Coti
- Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Udo Maierhofer
- Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Claus Rath
- Division of Anatomy, Center for Anatomy and Cell Biology, Medical University of Vienna, Vienna, Austria
| | - Paul Werner
- Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Christian Loewe
- Division of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Alfred Kocher
- Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Guenther Laufer
- Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Martin Andreas
- Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
16
|
Werner P, Gritsch J, Scherzer S, Gross C, Russo M, Coti I, Kocher A, Laufer G, Andreas M. Structural valve deterioration after aortic valve replacement with the Trifecta valve. Interact Cardiovasc Thorac Surg 2021; 32:39-46. [PMID: 33221889 DOI: 10.1093/icvts/ivaa236] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 08/24/2020] [Accepted: 09/16/2020] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES Despite promising short- and mid-term results for durability of the Trifecta valve, contradictory reports of early structural valve deterioration (SVD) do exist. We investigated the incidence of SVD after surgical aortic valve replacement (SAVR) with the Trifecta in our single-centre experience. METHODS Data of 347 consecutive patients (mean age 71.6 ± 9.5 years, 63.4% male) undergoing SAVR with the Trifecta between 2011 and 2017 were analysed. Clinical and echocardiographic reports were obtained with a median follow-up of 41 months (1114 patient years). RESULTS Isolated SAVR was performed in 122 patients (35.2%), whereas 225 patients (64.8%) underwent concomitant procedures. The median EuroSCORE II was 4.0 (0.9; 7.1) and 30-day mortality was 3.7% (n = 13). Kaplan-Meier estimates for the freedom of overall mortality at 1, 5 and 7 years were 88.7 ± 1.7%, 73.7 ± 2.6% and 64.7 ± 4.2%, respectively. SVD was observed in 25 patients (7.2%) with a median time to first diagnosis of 73 months. Freedom of SVD was 92.5 ± 0.9% at 5 years and 65.5 ± 7.1% at 7 years. Thirteen patients underwent reintervention for SVD (6 re-SAVR, 7 valve-in-valve), resulting in a freedom of reintervention for the SVD of 98.5 ± 1.1% at 5 years and 76.9 ± 6.9% at 7 years. CONCLUSIONS We herein report one of the highest rates of SVD after SAVR with the Trifecta. These data indicate that the durability of the prosthesis decreases at intermediate to long-term follow-up, leading to considerable rates of reintervention due to SVD.
Collapse
Affiliation(s)
- Paul Werner
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Jasmin Gritsch
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Sabine Scherzer
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Christoph Gross
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Marco Russo
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Iuliana Coti
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Alfred Kocher
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Guenther Laufer
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Martin Andreas
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
17
|
Arribas-Leal JM, Rivera-Caravaca JM, Aranda-Domene R, Moreno-Moreno JA, Espinosa-Garcia D, Jimenez-Aceituna A, Perez-Andreu J, Taboada-Martin R, Saura-Espin DR, Canovas-Lopez SJ. Mid-term outcomes of rapid deployment aortic prostheses in patients with small aortic annulus. Interact Cardiovasc Thorac Surg 2021; 33:695-701. [PMID: 34179967 DOI: 10.1093/icvts/ivab175] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 04/21/2021] [Accepted: 05/12/2021] [Indexed: 12/21/2022] Open
Abstract
OBJECTIVES The Edwards Intuity valve is a rapid deployment aortic prosthesis that favours less invasive approaches. However, evidence about the clinical behaviour of their smaller sizes is scarce. Herein, we studied haemodynamic behaviours and clinical outcomes of small Intuity prostheses (19-21 mm) in comparison to larger Intuity prostheses (>21 mm). METHODS This is an observational study including patients implanted with an Edwards Intuity rapid deployment aortic prosthesis. Patients with prosthesis sizes 19-21 and >21 mm were included. Baseline and perioperative variables, as well as adverse events during the follow-up were recorded and compared between groups. RESULTS A total of 122 patients (37% female, mean age 75 ± 4.5 years) were included, of whom 54 (45%) were implanted with a small prosthesis and 68 (55%) with a prosthesis >21 mm. There were no significant differences between patients with small Intuity prostheses and patients with larger prostheses regarding in-hospital mortality (2% vs 4%, P = 0.43) or mortality during the follow-up (3.41 vs 2.45 per 100 patients-years; P = 0.58). Survival in the small Intuity valve group was 95% at 1 year and 83% at 6 years, whereas in the larger Intuity valve group was 96% at 1 year and 78% at 6 years. The presence of a small prosthesis did not influence mid-term survival (log-rank P-value = 0.62). CONCLUSIONS This study showed good clinical performance of Intuity aortic prostheses with appropriate mid-term survival in patients with the small aortic annulus. Thus, the Edwards Intuity rapid deployment aortic prosthesis may be considered as a potential option in patients with the small aortic annulus.
Collapse
Affiliation(s)
- José M Arribas-Leal
- Cardiovascular Surgery Service, Virgen de la Arrixaca University Hospital, Instituto Murciano de Investigación Biosanitaria (IMIB-Arrixaca), Murcia, Spain
| | - José Miguel Rivera-Caravaca
- Department of Cardiology, Virgen de la Arrixaca University Hospital, University of Murcia, Instituto Murciano de Investigación Biosanitaria (IMIB-Arrixaca), CIBERCV, Murcia, Spain
| | - Ramón Aranda-Domene
- Cardiovascular Surgery Service, Virgen de la Arrixaca University Hospital, Instituto Murciano de Investigación Biosanitaria (IMIB-Arrixaca), Murcia, Spain
| | - José A Moreno-Moreno
- Cardiovascular Surgery Service, Virgen de la Arrixaca University Hospital, Instituto Murciano de Investigación Biosanitaria (IMIB-Arrixaca), Murcia, Spain
| | - Dolores Espinosa-Garcia
- Department of Cardiology, Virgen de la Arrixaca University Hospital, University of Murcia, Instituto Murciano de Investigación Biosanitaria (IMIB-Arrixaca), CIBERCV, Murcia, Spain
| | - Antonio Jimenez-Aceituna
- Cardiovascular Surgery Service, Virgen de la Arrixaca University Hospital, Instituto Murciano de Investigación Biosanitaria (IMIB-Arrixaca), Murcia, Spain
| | - Joaquín Perez-Andreu
- Cardiovascular Surgery Service, Virgen de la Arrixaca University Hospital, Instituto Murciano de Investigación Biosanitaria (IMIB-Arrixaca), Murcia, Spain
| | - Rubén Taboada-Martin
- Cardiovascular Surgery Service, Virgen de la Arrixaca University Hospital, Instituto Murciano de Investigación Biosanitaria (IMIB-Arrixaca), Murcia, Spain
| | - Daniel R Saura-Espin
- Department of Cardiology, Virgen de la Arrixaca University Hospital, University of Murcia, Instituto Murciano de Investigación Biosanitaria (IMIB-Arrixaca), CIBERCV, Murcia, Spain
| | - Sergio J Canovas-Lopez
- Cardiovascular Surgery Service, Virgen de la Arrixaca University Hospital, Instituto Murciano de Investigación Biosanitaria (IMIB-Arrixaca), Murcia, Spain
| |
Collapse
|
18
|
Andreas M, Berretta P, Solinas M, Santarpino G, Kappert U, Fiore A, Glauber M, Misfeld M, Savini C, Mikus E, Villa E, Phan K, Fischlein T, Meuris B, Martinelli G, Teoh K, Mignosa C, Shrestha M, Carrel TP, Yan T, Laufer G, Di Eusanio M. Minimally invasive access type related to outcomes of sutureless and rapid deployment valves. Eur J Cardiothorac Surg 2021; 58:1063-1071. [PMID: 32588056 PMCID: PMC7577292 DOI: 10.1093/ejcts/ezaa154] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2019] [Revised: 04/01/2020] [Accepted: 04/03/2020] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES Minimally invasive surgical techniques with optimal outcomes are of paramount importance. Sutureless and rapid deployment aortic valves are increasingly implanted via minimally invasive approaches. We aimed to analyse the procedural outcomes of a full sternotomy (FS) compared with those of minimally invasive cardiac surgery (MICS) and further assess MICS, namely ministernotomy (MS) and anterior right thoracotomy (ART). METHODS We selected all isolated aortic valve replacements in the Sutureless and Rapid Deployment Aortic Valve Replacement International Registry (SURD-IR, n = 2257) and performed propensity score matching to compare aortic valve replacement through FS or MICS (n = 508/group) as well as through MS and ART accesses (n = 569/group). RESULTS Postoperative mortality was 1.6% in FS and MICS patients who had a mean logistic EuroSCORE of 11%. Cross-clamp and cardiopulmonary bypass (CPB) times were shorter in the FS group than in the MICS group (mean difference 3.2 and 9.2 min; P < 0.001). Patients undergoing FS had a higher rate of acute kidney injury (5.6% vs 2.8%; P = 0.012). Direct comparison of MS and ART revealed longer mean cross-clamp and CPB times (12 and 16.7 min) in the ART group (P < 0.001). The postoperative outcome revealed a higher stroke rate (3.2% vs 1.2%; P = 0.043) as well as a longer postoperative intensive care unit [2 (1-3) vs 1 (1-3) days; P = 0.009] and hospital stay [11 (8-16) vs 8 (7-12) days; P < 0.001] in the MS group than in the ART group. CONCLUSIONS According to this non-randomized international registry, FS resulted in a higher rate of acute kidney injury. The ART access showed a lower stroke rate than MS and a shorter hospital stay than all other accesses. All these findings may be related to underlying patient risk factors.
Collapse
Affiliation(s)
- Martin Andreas
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Paolo Berretta
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ospedali Riuniti, Ancona, Italy
| | | | - Giuseppe Santarpino
- Città di Lecce Hospital, GVM Care & Research, Cotignola, Italy.,Cardiovascular Center, Paracelsus Medical University, Nuremberg, Germany
| | - Utz Kappert
- Department of Cardiac Surgery, University Heart Centre Dresden, Dresden, Germany
| | - Antonio Fiore
- Department of Cardiac Surgery, Henri Mondor University Hospital, Assistance Publique-Hôpitaux de Paris, Créteil, France
| | - Mattia Glauber
- Istituto Clinico Sant'Ambrogio, Clinical & Research Hospitals IRCCS Gruppo San Donato, Milan, Italy
| | - Martin Misfeld
- University Clinic for Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany.,Department of Cardiothoracic Surgery, The Royal Prince Alfred Hospital, Sydney, Australia
| | - Carlo Savini
- Cardiac Surgery Department, Sant'Orsola Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Elisa Mikus
- Cardiovascular Surgery Unit, Maria Cecilia Hospital GVM Care & Research, Cotignola, Italy
| | - Emmanuel Villa
- Cardiac Surgery Unit, Poliambulanza Foundation Hospital, Brescia, Italy
| | - Kevin Phan
- The Collaborative Research (CORE) Group, Sydney, Australia
| | - Theodor Fischlein
- Cardiovascular Center, Paracelsus Medical University, Nuremberg, Germany
| | - Bart Meuris
- Cardiac Surgery, Gasthuisberg, Cardiale Heelkunde, Leuven, Belgium
| | | | - Kevin Teoh
- Southlake Regional Health Centre, Newmarket, ON, Canada
| | - Carmelo Mignosa
- Department for the Treatment and Study of Cardiothoracic Diseases, Cardiothoracic Transplantation IRCCS-ISMETT, Palermo, Italy
| | - Malakh Shrestha
- Division of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Thierry P Carrel
- Department of Cardiovascular Surgery, University Hospital, University of Bern, Bern, Switzerland
| | - Tristan Yan
- Department of Cardiothoracic Surgery, The Royal Prince Alfred Hospital, Sydney, Australia.,The Collaborative Research (CORE) Group, Sydney, Australia
| | - Guenther Laufer
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Marco Di Eusanio
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ospedali Riuniti, Ancona, Italy.,The Collaborative Research (CORE) Group, Sydney, Australia
| |
Collapse
|
19
|
Herry M, Laghlam D, Touboul O, Nguyen LS, Estagnasié P, Brusset A, Squara P. Pacemaker implantation after aortic valve replacement: rapid-deployment Intuity® compared to conventional bioprostheses. Eur J Cardiothorac Surg 2021; 58:335-342. [PMID: 32215660 PMCID: PMC7373323 DOI: 10.1093/ejcts/ezaa068] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 02/03/2020] [Accepted: 02/05/2020] [Indexed: 02/06/2023] Open
Affiliation(s)
- Morgane Herry
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Driss Laghlam
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Olivier Touboul
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Lee S Nguyen
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Philippe Estagnasié
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Alain Brusset
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Pierre Squara
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
- Corresponding author. Department of Cardiology and Critical Care, CERIC, Clinique Ambroise Paré, 27 Boulevard Victor Hugo, 92200 Neuilly-sur-Seine, France. Tel: +33-6-07370425; e-mail: (P. Squara)
| |
Collapse
|
20
|
Klop IDG, Kougioumtzoglou AM, Kloppenburg GTL, van Putte BP, Sprangers MAG, Klein P, Nieuwkerk PT. Short-term outcome of the intuity rapid deployment prosthesis: a systematic review and meta-analysis. Interact Cardiovasc Thorac Surg 2021; 31:427-436. [PMID: 32910171 DOI: 10.1093/icvts/ivaa131] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 05/15/2020] [Accepted: 06/17/2020] [Indexed: 01/18/2023] Open
Abstract
OBJECTIVES Limited access aortic valve replacement is an alternative approach for the treatment of calcified aortic valve disease. To facilitate limited access aortic valve replacement, rapid deployment valve prostheses have been developed aiming to reduce surgical impact. This systematic review gives an overview of current literature regarding the INTUITY or INTUITY Elite rapid deployment biological valve prosthesis. METHODS Cochrane, Embase and MEDLINE were searched to identify relevant studies. All studies reporting on patients who underwent isolated or combined surgical aortic valve replacement with the INTUITY or INTUITY Elite valve prosthesis were considered eligible. Primary end points were technical success rate, 30-day mortality, cerebrovascular accident, paravalvular leak and permanent pacemaker implantation. Secondary end points included procedural data such as aortic cross-clamping time, cardiopulmonary bypass time and procedural approach. RESULTS A total of 16 articles fulfilled the inclusion and exclusion criteria and comprised 4.184 patients. Thirty-day mortality was 2.7% (1.9-3.7%), cerebrovascular accident 2.6% (1.4-4.7%), permanent pacemaker implantation 7.9% (6.6-9.5%) and severe postoperative paravalvular leak requiring a reintervention 3.3% (1.7-6.1%). Technical success rate varied between 93.9% and 100%. Conventional median sternotomy was most commonly performed, ranging from 21.7% to 89.6%. Upper hemi-sternotomy was performed more often than anterior right thoracotomy, ranging from 10.4% to 63.3% and 2.2% to 26.1%. The mean transvalvular pressure gradient ranged between 9.0 and 10.3 mmHg at 1 year postoperatively. CONCLUSIONS This review demonstrates that the technical success rate of the INTUITY or INTUITY Elite rapid deployment valve system is high, also in limited access aortic valve replacement. Mortality and cerebrovascular accident rates are low, but the need for postoperative permanent pacemaker implantation and reintervention rate for paravalvular leakage is increased.
Collapse
Affiliation(s)
| | - Athiná M Kougioumtzoglou
- Department of Cardiothoracic Surgery, Amsterdam University Medical Centers, Academic Medical Center, Amsterdam, Netherlands
| | | | - Bart P van Putte
- Department of Cardiothoracic Surgery, St. Antonius Ziekenhuis, Nieuwegein, Netherlands.,Department of Cardiothoracic Surgery, Amsterdam University Medical Centers, Academic Medical Center, Amsterdam, Netherlands
| | - Mirjam A G Sprangers
- Department of Psychology, Amsterdam University Medical Centers, Academic Medical Center, University of Amsterdam, Amsterdam Public Health Research Institute, Amsterdam, Netherlands
| | - Patrick Klein
- Department of Cardiothoracic Surgery, St. Antonius Ziekenhuis, Nieuwegein, Netherlands
| | - Pythia T Nieuwkerk
- Department of Psychology, Amsterdam University Medical Centers, Academic Medical Center, University of Amsterdam, Amsterdam Public Health Research Institute, Amsterdam, Netherlands
| |
Collapse
|
21
|
Sohn SH, Kim KH, Kang Y, Kim JS, Choi JW. Recovery from Conduction Abnormalities after Aortic Valve Replacement using Edwards Intuity. Ann Thorac Surg 2021; 112:1356-1362. [PMID: 33905729 DOI: 10.1016/j.athoracsur.2021.04.036] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 03/31/2021] [Accepted: 04/05/2021] [Indexed: 11/15/2022]
Abstract
PURPOSE This study investigated the incidences of various conduction abnormalities after rapid-deployment aortic valve replacement(RDAVR) using Edwards Intuity and the temporal changes of these abnormalities during the postoperative course. DESCRIPTION We modified the procedure by placing additional anchoring sutures and using a 5-mm videoscope to achieve 'complete annulus fitting'. Direct visual inspection by videoscopy inside and outside the valve guaranteed 'complete annulus fitting'. EVALUATION Overall 167 patients who underwent RDAVR during the study period were included in the analysis of postoperative conduction abnormalities. After RDAVR, third-degree atrioventricular block occurred in 18 patients(10.8%), but 15 patients recovered to sinus rhythm at median postoperative 10 days. Left or right bundle branch block occurred in 67 patients(40.1%), but 44 patients returned to their original rhythm at median postoperative 12 days. Delayed-onset conduction abnormalities occurred in 35 patients(21.0%) at median postoperative day 4, but they spontaneously regressed in 28 patients. CONCLUSIONS The incidence of conduction abnormalities after RDAVR was high, but most of these abnormalities spontaneously recovered. These good results may be attributed to our implantation technique.
Collapse
Affiliation(s)
- Suk Ho Sohn
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Kyung Hwan Kim
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
| | - Yoonjin Kang
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Ji Seong Kim
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Jae Woong Choi
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
22
|
Yamamoto T, Endo D, Yamaoka H, Matsushita S, Kajimoto K, Asai T, Amano A. A new technique that prevents paravalvular leakage after aortic valve replacement using a rapid-deployment valve system. J Card Surg 2021; 36:2225-2232. [PMID: 33783050 DOI: 10.1111/jocs.15513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 01/31/2021] [Indexed: 12/01/2022]
Abstract
BACKGROUND We report our 1-year single-center experience of a new technique of aortic valve replacement using a rapid-deployment valve (RD-AVR) to avoid postoperative complications. We also report the unexpected pitfalls and handling techniques that we have seen in past cases. METHODS We performed aortic valve replacement on 38 patients between May 2019 and April 2020. Their mean age was 74 years. The primary outcomes were in-hospital mortality and short-term results during a 1-year follow-up period, while the secondary outcomes were related to prosthetic valve function, especially paravalvular leakage (PVL). We further analyzed the relationship between the new technique and its outcomes. RESULTS The mean operative time was 196 min. There were no in-hospital deaths, and the mean duration of postoperative hospital stay was 11.8 days. Valvular measurements using three-dimensional computed tomography were larger and more accurate than those measured using ultrasonic echocardiography. Postoperative RD-AVR prosthetic valve function was excellent. However, PVL occurred in four cases 1 week and 1 year postoperatively and regurgitation did not improve. A gap associated with PVL was identified below the right-noncoronary commissure. To prevent PVL, we additionally stitched this gap in the later 18 cases; there was no case of PVL and no new pacemaker implantation in these cases. CONCLUSIONS PVL is more likely to occur if there is a gap below the R-N commissure, especially in cases with a large annulus; therefore, applying an additional stitch to the R-N commissure is extremely useful.
Collapse
Affiliation(s)
- Taira Yamamoto
- Department of Cardiovascular Surgery, Juntendo University, Tokyo, Japan
| | - Daisuke Endo
- Department of Cardiovascular Surgery, Juntendo University, Tokyo, Japan
| | - Hironobu Yamaoka
- Department of Cardiovascular Surgery, Edogawa Hospital, Tokyo, Japan
| | | | - Kan Kajimoto
- Department of Cardiovascular Surgery, Juntendo University, Tokyo, Japan
| | - Tohru Asai
- Department of Cardiovascular Surgery, Juntendo University, Tokyo, Japan
| | - Atsushi Amano
- Department of Cardiovascular Surgery, Juntendo University, Tokyo, Japan
| |
Collapse
|
23
|
Arribas JM, Rivera-Caravaca JM, Moreno JA, Aranda R, Masso J, Jiménez A, Pérez-Andreu J, Taboada R, Fernández M, Aguilar JM, García-Puente JJ, Lorenzo M, Gutiérrez F, de la Morena G, Jara R, Cánovas SJ. Experiencia de 7 años con la protesis aortica de rápido despliegue Edwards Intuity. CIRUGIA CARDIOVASCULAR 2021. [DOI: 10.1016/j.circv.2020.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
24
|
Useini D, Beluli B, Christ H, Schlömicher M, Ewais E, Haldenwang P, Patsalis P, Moustafine V, Bechtel M, Strauch J. Transcatheter aortic valve replacement using the SAPIEN 3 valve versus surgical aortic valve replacement using the rapid deployment INTUITY valve: Midterm outcomes. J Card Surg 2021; 36:610-617. [PMID: 33386755 DOI: 10.1111/jocs.15275] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2020] [Revised: 11/18/2020] [Accepted: 12/16/2020] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Little data have been published on the midterm effect of transapical/transfemoral-transcatheter aortic valve replacement (TA-/TF-TAVR) using the Edwards SAPIEN 3 valve (S3). We aimed to compare the outcomes after TA-/TF-TAVR utilizing the S3 (TA-/TF-S3) valve with those after surgical aortic valve replacement utilizing the rapid deployment Edwards INTUITY valve (RD-SAVR). METHODS Between March 2012 and April 2018, 122 patients with aortic stenosis underwent TA-S3, 77 patients underwent TF-S3 and 182 patients underwent RD-SAVR through partial sternotomy at our institution. We conducted clinical and echocardiographic midterm follow-ups. The primary outcomes of the study were the incidence of new pacemakers permanent pacemaker implantation (PPI), the occurrence of paravalvular leakage (PVL) and the hemodynamic performance of the valves. RESULTS All study groups were at intermediate surgical risk. The 30-day all-cause mortality and stroke rates in the TA-S3, TF-S3, and RD-SAVR groups were 4.1% and 1.6%, 3.9% and 2.6%, and 3.8% and 2.2%, respectively. The RD-SAVR group had significantly smaller PVL and PPI rates than did the TA-/TF-S3 group (p < .0001). At the discharge, the one-year postprocedure mean gradients were 9 ± 5.1/10 ± 4.5 mmHg, 11 ± 4.1/12 ± 3.8 mmHg, and 10.1 ± 4.3/10.4 ± 2.6 mmHg in the TA-S3, TF-S3, and RD-SAVR groups, respectively. Midterm valve thrombosis, Re-TAVR/SVAR were low and similar among the study groups, whereas endocarditis was higher in the TAVR group. CONCLUSION RD-SAVR was superior to TA-/TF-S3 in the PVL and PPI rates. We observed similar early outcomes and valve hemodynamics. The endocarditis was higher in the TAVR group.
Collapse
Affiliation(s)
- Dritan Useini
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Blerta Beluli
- Department of Internal Medicine, St. Anna Hospital, Herne, Germany
| | - Hildegard Christ
- Department of Medical Statistics, Institute of Medical Statistics and Computational Biology (IMSB), University Hospital of Cologne, Cologne, Germany
| | - Markus Schlömicher
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Elias Ewais
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Peter Haldenwang
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Polykarpos Patsalis
- Department of Cardiology and Angiology, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Vadim Moustafine
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Matthias Bechtel
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Justus Strauch
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| |
Collapse
|
25
|
Carrel T, Heinisch PP. History, development and clinical perspectives of sutureless and rapid deployment surgical aortic valve replacement. Ann Cardiothorac Surg 2020; 9:375-385. [PMID: 33102176 DOI: 10.21037/acs-2020-surd-18] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Degenerative aortic stenosis is the most frequent valvular heart disease in industrialized countries. Conservative treatment may beneficially influence symptoms but is never successful. Surgical aortic valve replacement (SAVR) was the only recognized treatment option to provide substantially prolonged survival until 2008. Operative mortality of isolated SAVR has been reported as low as 0.5% to 1% in experienced institutions, while long-term survival is close to that observed in a control healthy population of similar age. A multitude of studies have demonstrated the beneficial effects of SAVR with regard to improvement in quality of life and physical performance in the majority of symptomatic patients. In the last decade, transcatheter aortic valve implantation (TAVI) has emerged as an equal treatment modality, first in patients with high surgical risk and more recently in patients with intermediate and low surgical risk. Paravalvular regurgitation and the higher rate of pacemaker implantation remain points of consideration. Additionally, the long-term durability of TAVI devices and occurrence of stroke late after TAVI require additional analyses. Sutureless (SU-SAVR) and rapid deployment valve (R-SAVR) were designed to simplify and accelerate a conventional or less invasive surgical procedure while allowing complete excision of the calcified native valve. From 3 different implants tested more than 10 to 15 years ago, only two are available on the market today: the Perceval® valve from Liva Nova and the Intuity® sutureless prosthesis from Edwards Lifesciences. There has been extensive experience with these two devices in previous years and the results obtained are comparable to those observed following the use of conventional implants. The sutureless devices may be of particular interest for more complex and combined surgical procedures. This review summarizes the sutureless (SU-SAVR) and rapid deployment valve technologies and presents a clinical outlook for the patient population managed with these devices.
Collapse
Affiliation(s)
- Thierry Carrel
- Department for Cardiovascular Surgery, University Hospital and University of Bern, Bern, Switzerland
| | - Paul Philipp Heinisch
- Department for Cardiovascular Surgery, University Hospital and University of Bern, Bern, Switzerland
| |
Collapse
|
26
|
Schlömicher M, Bechtel M, Useini D, Naraghi H, Haldenwang PL, Moustafine V, Strauch JT. Single-Center Outcomes with Rapid Deployment Aortic Valve Replacement. Thorac Cardiovasc Surg 2020; 69:405-411. [PMID: 32674180 DOI: 10.1055/s-0040-1713660] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVES Rapid-deployment valves can reduce procedural times and may facilitate minimally invasive surgery. In our institution, more than 500 patients underwent rapid deployment aortic valve replacement (AVR). METHODS A total of 510 patients underwent rapid deployment AVR between March 2012 and September 2017, of whom 270 patients underwent isolated AVR and 240 underwent AVR with concomitant procedures. The cumulative follow-up time was 1,444 patient-years, the median follow-up time 2.8 years, respectively RESULTS: An early all-cause mortality of 3.5% (n = 18) was seen with a cumulative survival of 91.9 ± 2.2% after 12 months. Mean cross-clamp times were 37 ± 19 minutes for isolated AVR and 93 ± 29 minutes for AVR with concomitant procedures. The rate of new pacemaker implantation was 7.8% (n = 40). No case of structural degeneration occurred in the follow-up. Three (0.6%) cases of endocarditis were registered. CONCLUSIONS Rapid deployment AVR can be performed safely with low complication rates and good hemodynamic results. Therefore, the relevance in aortic valve surgery can be stressed.
Collapse
Affiliation(s)
- Markus Schlömicher
- Department of Cardiothoracic Surgery, Ruhr University Hospital Bergmannsheil, Bochum, Germany
| | - Matthias Bechtel
- Department of Cardiothoracic Surgery, Ruhr University Hospital Bergmannsheil, Bochum, Germany
| | - Dritan Useini
- Department of Cardiothoracic Surgery, Ruhr University Hospital Bergmannsheil, Bochum, Germany
| | - Hamid Naraghi
- Department of Cardiothoracic Surgery, Ruhr University Hospital Bergmannsheil, Bochum, Germany
| | - Peter Lukas Haldenwang
- Department of Cardiothoracic Surgery, Ruhr University Hospital Bergmannsheil, Bochum, Germany
| | - Vadim Moustafine
- Department of Cardiothoracic Surgery, Ruhr University Hospital Bergmannsheil, Bochum, Germany
| | - Justus T Strauch
- Department of Cardiothoracic Surgery, Ruhr University Hospital Bergmannsheil, Bochum, Germany
| |
Collapse
|
27
|
Di Eusanio M, Berretta P. The sutureless and rapid-deployment aortic valve replacement international registry: lessons learned from more than 4,500 patients. Ann Cardiothorac Surg 2020; 9:289-297. [PMID: 32832410 PMCID: PMC7415696 DOI: 10.21037/acs-2020-surd-21] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 04/28/2020] [Indexed: 01/04/2023]
Abstract
The treatment options for patients with aortic valve disease have considerably expanded over the last decade. The remarkable advances in catheter-based technology, the popularizing of minimally invasive (MI) surgery, and the introduction of new valve technologies, such as sutureless and rapid-deployment (SURD) valves have led to a paradigm shift in the management of aortic valve pathologies. Yet, given their recent introduction, the current evidence on sutureless and rapid-deployment aortic valve replacement (SURD-AVR) has been limited thus far. The Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry (SURD-IR) was established in 2015 by a consortium of 18 research centers to assess safety, efficacy, short- and long-term outcomes of SURD-AVR interventions. The present keynote lecture aims to assess and comment on the real-world evidence for SURD-AVR surgery generated from the SURD-IR.
Collapse
Affiliation(s)
- Marco Di Eusanio
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy
| | - Paolo Berretta
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy
| |
Collapse
|
28
|
Williams ML, Flynn CD, Mamo AA, Tian DH, Kappert U, Wilbring M, Folliguet T, Fiore A, Miceli A, D'Onofrio A, Cibin G, Gerosa G, Glauber M, Fischlein T, Pollari F. Long-term outcomes of sutureless and rapid-deployment aortic valve replacement: a systematic review and meta-analysis. Ann Cardiothorac Surg 2020; 9:265-279. [PMID: 32832408 DOI: 10.21037/acs-2020-surd-25] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Background Sutureless and rapid-deployment aortic valve replacement (SURD-AVR) has become a prominent area of research as the medical community evaluate its place amongst other aortic valve interventions. The main advantages of SURD-AVR established to date are the reduced cross-clamp and cardiopulmonary bypass (CPB) times, as well as facilitating minimally invasive surgery in high-risk surgical patients. This current systematic review and meta-analysis, to our knowledge, is the first focusing on long-term outcomes regarding safety, efficacy and durability of SURD-AVR from available current literature. Methods A literature search via six electronic databases was performed from their inception to November 2019. Inclusion criteria for this systematic review included survival and postoperative echocardiographic outcomes greater than five years in patients who underwent SURD-AVR with either Perceval or Intuity valves. Studies were identified and data extracted by two independent reviewers. Long-term survival outcomes were aggregated using digitized Kaplan-Meier curves where available. Results After applying predefined inclusion and exclusion criteria, four studies were identified for review. All four studies were observational and in total reported data for 1,998 patients. Almost half (42.4%) of patients underwent SURD-AVR via full sternotomy, with almost one third (30.1%) also undergoing concomitant cardiac procedures. Aggregate overall survival rates at 1-, 2-, 3-, and 5-year follow-up were 94.9%, 91.2%, 89.0%, and 84.2%, respectively. Incidence of strokes (4.8%), severe paravalvular leaks (PVLs) (1.5%) and permanent pacemaker (PPM) insertion (8.2%) at up to 5-year follow-up were acceptable. At 5-year follow-up hemodynamic outcomes were also acceptable for mean pressure gradient (MPG) (range, 8.8-13.6 mmHg), peak pressure gradient (PPG) (range, 18.9-21.1 mmHg) and effective orifice area (EOA) (range, 1.5-1.8 cm2). Conclusions Evaluation of the evidence reporting long-term outcomes of SURD-AVR suggests that it is a safe procedure for AVR with low rates of complications. Long-term outcomes presented in this review show that not only does SURD-AVR have acceptable survival rates, but also good hemodynamic performance at 5-year follow-up.
Collapse
Affiliation(s)
- Michael L Williams
- Department of Cardiothoracic Surgery, Royal Prince Alfred Hospital, Sydney, Australia.,The Collaborative Research (CORE) Group, Macquarie University, Sydney, Australia.,The Baird Institute of Applied Heart & Lung Surgical Research, Sydney, Australia.,The University of Sydney, Sydney, Australia
| | - Campbell D Flynn
- The Collaborative Research (CORE) Group, Macquarie University, Sydney, Australia.,Department of Cardiothoracic Surgery, Epworth Hospital, Richmond, Melbourne, Australia
| | - Andrew A Mamo
- Department of Cardiology, Prince of Wales Hospital, Sydney, Australia
| | - David H Tian
- The Collaborative Research (CORE) Group, Macquarie University, Sydney, Australia.,Department of Anaesthesia and Perioperative Medicine, Westmead Hospital, Sydney, Australia
| | - Utz Kappert
- Department of Cardiac Surgery, University Heart Center Dresden, Dresden, Germany
| | - Manuel Wilbring
- Department of Cardiac Surgery, University Heart Center Dresden, Dresden, Germany
| | - Thierry Folliguet
- Department of Cardiac Surgery, Henri Mondor University Hospital, Assistance Publique-Hôpitaux de Paris, Créteil, France
| | - Antonio Fiore
- Department of Cardiac Surgery, Henri Mondor University Hospital, Assistance Publique-Hôpitaux de Paris, Créteil, France
| | - Antonio Miceli
- Minimally Invasive Cardiac Surgery, Istituto Clinico Sant'Ambrogio, Milano, Italy
| | | | - Giorgia Cibin
- Division of Cardiac Surgery, University of Padova, Padova, Italy
| | - Gino Gerosa
- Division of Cardiac Surgery, University of Padova, Padova, Italy
| | - Mattia Glauber
- Minimally Invasive Cardiac Surgery Department, Istituto Clinico Sant'Ambrogio - Gruppo San Donato, Milano, Italy
| | - Theodor Fischlein
- Cardiac Surgery, Paracelsus Medical University - Klinikum Nürnberg, Nuremberg, Germany
| | - Francesco Pollari
- Cardiac Surgery, Paracelsus Medical University - Klinikum Nürnberg, Nuremberg, Germany
| |
Collapse
|
29
|
Coti I, Haberl T, Scherzer S, Werner P, Shabanian S, Kocher A, Laufer G, Andreas M. Outcome of rapid deployment aortic valves: long-term experience after 700 implants. Ann Cardiothorac Surg 2020; 9:314-321. [PMID: 32832413 DOI: 10.21037/acs.2020.04.01] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Background The Edwards Intuity Valve System is a bioprosthesis with a balloon-expandable stent frame which enables rapid-deployment (RD). We aimed to analyze our single-center long-term experience with a follow-up until 9 years after aortic valve replacement (AVR) with this bioprosthesis. Methods Between May 2010 and May 2019, 700 consecutive patients with severe aortic stenosis or combined aortic valve disease, implanted with a RD valve at our institution, were included in a prospective database. Median follow-up was 19 months and the total accumulated follow-up was 2,140 patient-years. Pre-operative characteristics, operative parameters, survival rates, valve-related adverse events and valve hemodynamics were assessed. Results Mean age was 74±8 years, 45% female. Concomitant procedures were performed in 339 (48.4%) patients. In case of isolated AVR (361/700), a minimally invasive surgical (MIS) approach was conducted in 283 patients (78.4%). Cardio-pulmonary bypass (CPB) and cross-clamp times for isolated AVR were 107.7±28.2 and 73.8±21.3 minutes for MIS approaches and 92.8±28.8 and 57.5±20.6 minutes for full sternotomy (P<0.001), respectively. Mean gradients at discharge, 1, 3 and 5 years were 13±5, 11±4, 12±5 and 13±8 mmHg. New early pacemaker implantation was required in 8.9% of patients. Re-intervention or re-operation with valve explantation for structural degeneration, non-structural dysfunction or endocarditis, occurred in 21 cases (3%). Thirty-day mortality was 0.7% (5/700) and overall survival at 1, 3 and 5 years was 98%, 91% and 76%. Conclusions We report excellent long-term results in this updated single center experience for RD aortic valves regarding durability, safety and hemodynamic performance.
Collapse
Affiliation(s)
- Iuliana Coti
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Haberl
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Sabine Scherzer
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Paul Werner
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Shiva Shabanian
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Alfred Kocher
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Guenther Laufer
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Martin Andreas
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
30
|
Krane M, Boehm J, Prinzing A, Ziegelmueller J, Holfeld J, Lange R. Excellent Hemodynamic Performance After Aortic Valve Neocuspidization Using Autologous Pericardium. Ann Thorac Surg 2020; 111:126-133. [PMID: 32540439 DOI: 10.1016/j.athoracsur.2020.04.108] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Revised: 03/27/2020] [Accepted: 04/20/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND Aortic valve neocuspidization (AVNeo) for trileaflet aortic valve reconstruction using autologous pericardium (Ozaki procedure) offers an alternative treatment modality to overcome drawbacks of conventional prosthetic aortic valve replacement. METHODS Between October 2016 and April 2019, 103 patients underwent surgery. Mean follow-up was 426 ± 270 days. Aortic stenosis was the leading diagnosis in 80 patients (77.7%) and aortic regurgitation in 23 (22.3%), respectively. Mean age was 54.0 ± 16.4 years (range, 13.8-78.5). A bicuspid valve was found in 81 patients (78.6%). Transthoracic echocardiography was performed at discharge and at 6 to 12 months after surgery. During AVNeo surgery valve sizing for an Abbott/St Jude Trifecta bioprosthesis (virtually implanted Trifecta bioprosthesis; St Jude Medical, St Paul, MN) was performed to compare pressure gradients and effective orifice area with published data. RESULTS Trileaflet aortic valve reconstruction was achieved in all patients. In 38 patients neocommissures were created (36.9%). Mean cross-clamp time was 135 ± 20 minutes. Four patients underwent reoperation; the overall freedom from reoperation was 96.1%. Echocardiographic 6- to 12-months follow-up after surgery was available in 93.8% of patients and did not show any change in hemodynamic parameters compared with discharge. Comparison between AVNeo and virtually implanted Trifecta Bioprosthesis revealed a significantly lower mean pressure gradient (8.5 ± 3.7 mm Hg vs 10.2 ± 2.0 mm Hg, P < .001) and higher mean effective orifice area (2.2 ± 0.7 cm2 vs 2.1 ± 0.4 cm2, P = .037) for AVNeo. CONCLUSIONS AVNeo shows low reoperation rates after surgery within the first 2 years. The hemodynamic performance is excellent, and the effective orifice area and mean pressure gradient remain stable within the first year.
Collapse
Affiliation(s)
- Markus Krane
- Department of Cardiovascular Surgery, German Heart Center Munich, Technical University Munich, Munich, Germany; Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Center, Technical University Munich, Munich, Germany; DZHK (German Center for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany
| | - Johannes Boehm
- Department of Cardiovascular Surgery, German Heart Center Munich, Technical University Munich, Munich, Germany; Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Center, Technical University Munich, Munich, Germany.
| | - Anatol Prinzing
- Department of Cardiovascular Surgery, German Heart Center Munich, Technical University Munich, Munich, Germany; Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Center, Technical University Munich, Munich, Germany
| | - Johannes Ziegelmueller
- Department of Cardiovascular Surgery, German Heart Center Munich, Technical University Munich, Munich, Germany; Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Center, Technical University Munich, Munich, Germany
| | - Johannes Holfeld
- Department of Cardiac Surgery, Medical University of Innsbruck, Innsbruck, Austria
| | - Rüdiger Lange
- Department of Cardiovascular Surgery, German Heart Center Munich, Technical University Munich, Munich, Germany; Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Center, Technical University Munich, Munich, Germany; DZHK (German Center for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany
| |
Collapse
|
31
|
Coti I, Haberl T, Scherzer S, Shabanian S, Binder T, Kocher A, Laufer G, Andreas M. Rapid-Deployment Aortic Valves for Patients With a Small Aortic Root: A Single-Center Experience. Ann Thorac Surg 2020; 110:1549-1556. [PMID: 32205113 DOI: 10.1016/j.athoracsur.2020.02.030] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 11/28/2019] [Accepted: 02/04/2020] [Indexed: 11/24/2022]
Abstract
BACKGROUND Aortic valve replacement in patients with a small aortic root is a matter of concern in terms of prosthesis-patient mismatch. We evaluated the survival and hemodynamic performance after implantation of a small rapid-deployment aortic valve (EDWARDS INTUITY valve system sizes 19 and 21 mm). METHODS Between May 2010 and November 2018, 659 consecutive patients with severe aortic stenosis who received a rapid-deployment valve were included in a prospective and ongoing database. A small aortic bioprosthesis (sizes 19 mm and 21 mm) was implanted in 217 (32.9%) patients (mean age 74.9 ± 7.9 years, 85.3% women). Preoperative characteristics, operative parameters, and postoperative outcomes were assessed. RESULTS Mean gradients at discharge and 1 year were 14.8 ± 5.6 mm Hg and 13.6 ± 4.9 mm Hg, respectively. Mean effective orifice area and the indexed effective orifice area at discharge were 1.55 ± 0.36 cm2 and 0.87 ± 0.22 cm2/m2, respectively, and prosthesis-patient mismatch occurred in 77 (35.5%) patients (25.8% moderate and 9.7% severe). Perioperative mortality was 1.8% (n = 4 of 217) and overall survival at 1 year and 5 years was 91% and 79%, respectively. The presence of any prosthesis-patient mismatch degree did not have a significant influence on overall survival (hazard ratio, 0.95; 95% confidence interval, 0.75-1.19; P = .638). At the last follow-up, mean New York Heart Association functional class was 1.5 ± 0.7 vs 2.8 ± 0.6 at baseline (P < .001). CONCLUSIONS Surgical aortic valve replacement with rapid-deployment valves has shown improved results concerning hemodynamic performance, with decreased rates of prosthesis-patient mismatch. We observed excellent early-term and midterm survival and a significant improvement in functional class in this subgroup of patients with a small annulus.
Collapse
Affiliation(s)
- Iuliana Coti
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Haberl
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Sabine Scherzer
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Shiva Shabanian
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Binder
- Division of Cardiology, Department of Internal Medicine II, Medical University of Vienna, Vienna, Austria
| | - Alfred Kocher
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Guenther Laufer
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Martin Andreas
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria.
| |
Collapse
|
32
|
Useini D, Beluli B, Schlömicher M, Haldenwang P, Bechtel M, Strauch J. Valve-in-Valve After Edwards INTUITY Valve Implantation in Small Aortic Annulus. Ann Thorac Surg 2020; 110:e189-e192. [PMID: 32114049 DOI: 10.1016/j.athoracsur.2020.01.029] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2019] [Accepted: 01/10/2020] [Indexed: 11/24/2022]
Abstract
The Edwards INTUITY aortic valve has in recent years played a significant role in facilitating surgical aortic valve replacement. Owing to the excellent hemodynamic characteristics and relatively new usage of this bioprosthetic aortic valve, the structural valve deterioration is an extremely rare complication; therefore, the treatment options of degenerated INTUITY valve with stenotic features have not been studied. We report the feasibility and safety of transcatheter valve-in-valve treatment for degenerated, stenotic INTUITY valve using the balloon expanding transcatheter aortic valve SAPIEN 3 in a small aortic annulus.
Collapse
Affiliation(s)
- Dritan Useini
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany.
| | - Blerta Beluli
- Department of Internal Medicine, St. Anna Hospital, Herne, Germany
| | - Markus Schlömicher
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Peter Haldenwang
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Matthias Bechtel
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Justus Strauch
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| |
Collapse
|
33
|
Coti I, Schukro C, Drevinja F, Haberl T, Kaider A, Kocher A, Laufer G, Andreas M. Conduction disturbances following surgical aortic valve replacement with a rapid-deployment bioprosthesis. J Thorac Cardiovasc Surg 2020; 162:803-811. [PMID: 32204909 DOI: 10.1016/j.jtcvs.2020.01.083] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 01/12/2020] [Accepted: 01/19/2020] [Indexed: 12/14/2022]
Abstract
BACKGROUND The implantation of rapid-deployment aortic valves may interfere with the conduction system of the heart. This study evaluates the occurrence and predictive factors of conduction anomalies in patients undergoing surgical aortic valve replacement (SAVR) with a rapid-deployment balloon-expandable bioprosthesis in a single-center, real-world experience. METHODS Between May 2010 and April 2019, 700 consecutive patients were included in a prospective, ongoing database with a longitudinal follow-up preoperatively, at discharge, and at 3 months, 1 year, 3 years, and 5 years postoperatively. Thirty-seven patients (5.3%) had a permanent pacemaker at baseline and were excluded from further analysis, leaving 663 patients for analysis. Assessment of conduction anomalies was performed by electrocardiography (ECG) monitoring and repeated 12-lead ECG during the hospital stay and at postoperative follow-ups. RESULTS Preoperatively, 126 patients (19.0%) presented with different conduction disturbances. New permanent pacemaker implantation (PPI) occurred in 61 patients during the first 14 days (cumulative incidence, 9.4%). The indication for PPI was complete atrioventricular block in 47 cases (77%). Preoperative conduction anomalies, such as right bundle branch block, as well as operative characteristics (concomitant procedures) were found to be independent predictors for new PPI. One-year survival was 98% in patients with new early PPI and 96% in those without new early PPI (P = .60). CONCLUSIONS The PPI rate was in the range of previous reports for rapid-deployment prostheses. PPI did not have a significant influence on short- to intermediate-term survival. Case selection with exclusion of patients presenting with baseline conduction disturbances may decrease the rate of new PPIs after SAVR with rapid-deployment balloon-expandable bioprostheses.
Collapse
Affiliation(s)
- Iuliana Coti
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Christoph Schukro
- Division of Cardiology, Department of Internal Medicine II, Medical University of Vienna, Vienna, Austria
| | - Fitim Drevinja
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Haberl
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Alexandra Kaider
- Center for Medical Statistics, Informatics, and Intelligent Systems, Medical University of Vienna, Vienna, Austria
| | - Alfred Kocher
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Guenther Laufer
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Martin Andreas
- Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria.
| |
Collapse
|
34
|
Chen J, Yang J, Zhang L, Ma W, Lu S, Wang C, Hong T. Optimizations of stent and tissue leaflets in a new surgical bovine pericardial valve. J Thorac Dis 2020; 11:4855-4858. [PMID: 31903276 DOI: 10.21037/jtd.2019.10.32] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Jinmiao Chen
- Department of Cardiac Surgery, Zhongshan Hospital, Fudan University, Shanghai 200032, China.,Shanghai Engineering Research Center of Heart Valve, Shanghai 200032, China.,Shanghai Institute of Cardiovascular Disease, Shanghai 200032, China
| | - Jun Yang
- Shanghai Cingular Biotech Corporation, Shanghai 201318, China
| | - Li Zhang
- Shanghai Cingular Biotech Corporation, Shanghai 201318, China
| | - Wenrui Ma
- Department of Cardiac Surgery, Zhongshan Hospital, Fudan University, Shanghai 200032, China.,Shanghai Engineering Research Center of Heart Valve, Shanghai 200032, China.,Shanghai Institute of Cardiovascular Disease, Shanghai 200032, China
| | - Shuyang Lu
- Department of Cardiac Surgery, Zhongshan Hospital, Fudan University, Shanghai 200032, China.,Shanghai Engineering Research Center of Heart Valve, Shanghai 200032, China.,Shanghai Institute of Cardiovascular Disease, Shanghai 200032, China
| | - Chunsheng Wang
- Department of Cardiac Surgery, Zhongshan Hospital, Fudan University, Shanghai 200032, China.,Shanghai Engineering Research Center of Heart Valve, Shanghai 200032, China.,Shanghai Institute of Cardiovascular Disease, Shanghai 200032, China
| | - Tao Hong
- Department of Cardiac Surgery, Zhongshan Hospital, Fudan University, Shanghai 200032, China.,Shanghai Engineering Research Center of Heart Valve, Shanghai 200032, China.,Shanghai Institute of Cardiovascular Disease, Shanghai 200032, China
| |
Collapse
|