1
|
Molitor N, Saleem-Talib S, Ramanna H, Hofer D, Breitenstein A, Steffel J. Leadless pacemaker implantation via the internal jugular vein. Europace 2024; 26:euae199. [PMID: 39051875 PMCID: PMC11304476 DOI: 10.1093/europace/euae199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2024] [Accepted: 07/16/2024] [Indexed: 07/27/2024] Open
Abstract
AIMS Leadless pacemaker therapy was introduced to overcome lead- and pocket-related complications in conventional transvenous pacemaker systems. Implantation via the femoral vein, however, may not always be feasible. The aim of this study was to evaluate leadless pacemaker implantation using a jugular vein approach and compare it to the standard implantation via the femoral vein. METHODS AND RESULTS The records of the first consecutive 100 patients undergoing Micra™ leadless pacemaker implantation via the right internal jugular vein from two centres were included in this study. Peri-procedural safety and efficacy of the jugular approach were compared to the first 100 patients using a femoral implantation approach at the University Hospital Zurich. One hundred patients underwent successful implantation of a leadless pacemaker via the internal jugular vein (mean age, 81.18 ± 8.29, 60% males). Mean procedure time was 35.63 ± 10.29 min with a mean fluoroscopy time of 4.66 ± 5.16 min. The device was positioned at the inferior septum in 25 patients, at the high septum in 24 patients, and mid-septum in 51 patients. The mean pacing threshold was 0.56 ± 0.35 V at 0.24 ms pulse width with a sensed amplitude of 10.0 ± 4.4 mV. At follow-up, electrical parameters remained stable in all patients. Compared with femoral implantation, patients undergoing the jugular approach were of similar age and had similar comorbidities. Mean procedure (48.9 ± 21.0 min) and fluoroscopy times (7.7 ± 7.8 min, both P < 0.01) were shorter compared to the femoral approach. Electrical parameters were similar between the two approaches. There were only two complications during jugular veinous implantations (1 pericardial effusion and 1 dislocation), compared to 16 complications using the femoral approach (1 pericardial effusion, 2 femoral artery injuries, and 13 major groin haematomas). CONCLUSION The jugular approach may represent a safe and efficient alternative to femoral implantation of the Micra leadless pacemaker.
Collapse
Affiliation(s)
- Nadine Molitor
- Department of Cardiology, University Heart Center, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
| | | | - Hemanth Ramanna
- Department of Cardiology, Haga Teaching Hospital, The Hague, The Netherlands
- The Hague University of Applied Sciences, The Hague, The Netherlands
| | - Daniel Hofer
- Department of Cardiology, Triemlispial, Zurich, Switzerland
| | - Alexander Breitenstein
- Department of Cardiology, University Heart Center, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
| | - Jan Steffel
- HeartClinic, Hirslanden Clinic, Zurich, Switzerland
| |
Collapse
|
2
|
Tam MTK, Cheng YW, Chan JYS, Chan CP, Au ACK, Fan KWS, Chim TMY, Kwok WY, Fong FK, Lai A, Tan GM, Yan BP. Aveir VR real-world performance and chronic pacing threshold prediction using mapping and fixation electrical data. Europace 2024; 26:euae051. [PMID: 38457487 PMCID: PMC10923508 DOI: 10.1093/europace/euae051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Accepted: 02/14/2024] [Indexed: 03/10/2024] Open
Abstract
AIMS Aveir VR performance and predictors for its pacing threshold (PCT) in a real-world cohort were investigated. METHODS Electrical measurements at various stages of an Aveir VR implant were prospectively collected. Predictors for 3-month PCT were studied. A retrospective cohort of consecutive 139 Micra implants was used to compare the PCT evolution. High PCT was defined as ≥1.5 V, using a pulse width of 0.4 ms for Aveir and 0.24 ms for Micra. Excellent PCT was defined as ≤0.5 V at the respective pulse width. RESULTS Among the 123 consecutive Aveir VR implant attempts, 122 (99.2%) were successful. The majority were of advanced age (mean 79.7) and small body size (mean BSA 1.60). Two patients (1.6%) experienced complications, including one pericardial effusion after device reposition and one intraoperative device dislodgement. Eighty-eight patients reached a 3-month follow-up. Aveir 3-month PCT was correlated with impedance at mapping (P = 0.015), tether mode (P < 0.001), end-of-procedure (P < 0.001), and mapping PCT (P = 0.035), but not with PCTs after fixation (P > 0.05). Tether mode impedance >470 ohms had 88% sensitivity and 71% specificity in predicting excellent 3-month PCT. Although it is more common for Aveir to have high PCT at end of procedure (11.5% for Aveir and 2.2% for Micra, P = 0.004), the rate at 3 months was similar (2.3% for Aveir and 3.1% for Micra, P = 1.000). CONCLUSION Aveir VR demonstrated satisfactory performance in this high-risk cohort. Pacing thresholds tend to improve to a greater extent than Micra after implantation. The PCT after fixation, even after a waiting period, has limited predictive value for the chronic threshold. Low-mapping PCT and high intraoperative impedance predict chronic low PCT.
Collapse
Affiliation(s)
- Mark T K Tam
- Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, NT, Hong Kong
| | - Yuet-Wong Cheng
- Division of Cardiology, Department of Medicine, Queen Elizabeth Hospital, 30 Gascoigne Road, KLN, Hong Kong
| | - Joseph Y S Chan
- Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, NT, Hong Kong
| | - Chin-Pang Chan
- Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, NT, Hong Kong
| | - Alex C K Au
- Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, NT, Hong Kong
| | - Katie W S Fan
- Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, NT, Hong Kong
| | - Thomas M Y Chim
- Division of Cardiology, Department of Medicine, Queen Elizabeth Hospital, 30 Gascoigne Road, KLN, Hong Kong
| | - Wan-Ying Kwok
- Division of Cardiology, Department of Medicine, Queen Elizabeth Hospital, 30 Gascoigne Road, KLN, Hong Kong
| | - Fuk-Kei Fong
- Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, NT, Hong Kong
| | - Angel Lai
- Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, NT, Hong Kong
| | - Guang-Ming Tan
- Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, NT, Hong Kong
| | - Bryan P Yan
- Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, NT, Hong Kong
| |
Collapse
|
3
|
Lenormand T, Abou Khalil K, Bodin A, Babuty D, Bisson A, Clementy N. Leadless cardiac pacing: Results from a large single-centre experience. Arch Cardiovasc Dis 2023; 116:316-323. [PMID: 37236828 DOI: 10.1016/j.acvd.2023.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 04/25/2023] [Accepted: 04/26/2023] [Indexed: 05/28/2023]
Abstract
BACKGROUND The efficacy and safety of leadless cardiac pacing as an alternative to conventional transvenous cardiac pacing in selected patients have been widely reported. AIM To report the experience of a high-volume implantation centre with older and new generations of leadless pacemakers. METHODS This retrospective observational study included the first consecutive 400 patients who underwent implantation of a leadless pacemaker in our centre. Complications and electrical parameters were evaluated during follow-up, comparing patients implanted with first-generation (Micra™ VR) and second-generation (Micra™ AV) leadless pacemakers (Medtronic, Minneapolis, MN, USA). Data were collected by a review of medical files. RESULTS Among 400 procedures, there were 328 Micra™ VR pacemakers and 72 Micra™ AV pacemakers implanted, followed for a median of 16 months (694 patient-years). The mean age was 77 years and both groups had a high burden of co-morbidities. Implantation success rate was 99.5%. A total of 87.5% of patients were discharged the day after the procedure. The pacing threshold remained stable and<2V in 96.5% of all patients. The perioperative complication rate at 30 days was 3.5%. Outcomes were similar between the two groups. CONCLUSION Leadless cardiac pacing is a safe and efficient alternative to conventional transvenous cardiac pacing.
Collapse
Affiliation(s)
- Thibault Lenormand
- Department of Cardiology, Tours University Hospital, 37000 Tours, France.
| | - Kassem Abou Khalil
- Department of Cardiology, Tours University Hospital, 37000 Tours, France
| | - Alexandre Bodin
- Department of Cardiology, Tours University Hospital, 37000 Tours, France
| | - Dominique Babuty
- Department of Cardiology, Tours University Hospital, 37000 Tours, France
| | - Arnaud Bisson
- Department of Cardiology, Tours University Hospital, 37000 Tours, France; Department of Cardiology, Orléans Hospital Centre, 45000 Orléans, France
| | - Nicolas Clementy
- Cardiology Department, Clinique du Millénaire, 34000 Montpellier, France
| |
Collapse
|
4
|
Mizukami A, Miyakuni S, Nakada R, Kobayashi T, Kawakami T, Takegawa K, Arai H, Hiroki J, Yoshioka K, Otani H, Ono M, Yamashita S, Ueshima D, Suzuki M, Matsumura A, Goya M, Sasano T. The angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation. J Arrhythm 2023; 39:10-17. [PMID: 36733332 PMCID: PMC9885318 DOI: 10.1002/joa3.12797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 10/26/2022] [Accepted: 11/11/2022] [Indexed: 11/25/2022] Open
Abstract
Background Micra leadless pacemaker is secured to the myocardium by engagement of at least 2/4 tines confirmed with pull and hold test. However, the pull and hold test is sometimes difficult to assess. This study was performed to evaluate whether the angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation. Methods We retrospectively enrolled 93 consecutive patients (52.7% male, age 82.4 ± 9.4 years), who received Micra implantation from September 2017 to June 2020 at our institution. After deployment and before the pull and hold test, the angle of the visible tines to the body of the pacemaker was measured using the RAO view of the fluoroscopy image. The engagement of the tines was then confirmed with the pull and hold test. Results A total of 326 tines were analyzed. The angle of the engaged tines was significantly lower than the non-engaged tines (9.2 degrees [4.0-14.0] vs. 16.6 degrees [14.2-18.8], p < .0001). All tines with angles <10 degrees were engaged. In higher angles, engagement could not be predicted. Conclusion A low angle of the tines before the pull and hold test can predict engagement of the tines in Micra leadless pacemaker implantation. The tines which are already open after deployment may be presumed that they are engaged.
Collapse
Affiliation(s)
| | | | - Ryo Nakada
- Department of CardiologyKameda Medical CenterChibaJapan
| | | | | | - Koki Takegawa
- Department of CardiologyKameda Medical CenterChibaJapan
| | - Hirofumi Arai
- Department of CardiologyYokohama City Minato Red Cross HospitalYokohamaJapan
| | - Jiro Hiroki
- Department of CardiologyKameda Medical CenterChibaJapan
| | | | | | - Maki Ono
- Department of CardiologyKameda Medical CenterChibaJapan
| | - Shu Yamashita
- Department of CardiologyKameda Medical CenterChibaJapan
| | | | - Makoto Suzuki
- Department of CardiologyYokohama Minami Kyosai HospitalYokohamaJapan
| | | | - Masahiko Goya
- Department of Cardiovascular MedicineTokyo Medical and Dental UniversityTokyoJapan
| | - Tetsuo Sasano
- Department of Cardiovascular MedicineTokyo Medical and Dental UniversityTokyoJapan
| |
Collapse
|
5
|
Tonegawa-Kuji R, Inoue YY, Nakai M, Kanaoka K, Sumita Y, Miyazaki Y, Wakamiya A, Shimamoto K, Ueda N, Nakajima K, Wada M, Kamakura T, Yamagata K, Ishibashi K, Miyamoto K, Nagase S, Aiba T, Miyamoto Y, Iwanaga Y, Kusano K. Differences in patient characteristics, clinical practice and outcomes of cardiac implantable electric device therapy between Japan and the USA: a cross-sectional study using data from nationally representative administrative databases. BMJ Open 2023; 13:e068124. [PMID: 36639209 PMCID: PMC9843182 DOI: 10.1136/bmjopen-2022-068124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
OBJECTIVES To identify differences in patient characteristics, clinical practice and outcomes of cardiac implantable electronic device (CIED) therapy between Japan and the USA. DESIGN A cross-sectional study. SETTING Nationally representative administrative databases from Japan and the USA containing hospitalisations with first-time implantations of pacemakers, implantable cardioverter-defibrillators (ICD) and cardiac-resynchronisation therapy with or without defibrillators (CRTP/CRTD). PARTICIPANTS Patients hospitalised with first-time implantations of CIEDs. OUTCOME MEASURES In-hospital mortality, in-hospital complication and 30-day readmission rates. RESULTS Overall, 107 339 (median age 78 (71-84), 48 415 women) and 295 584 (age 76 (67-83), 127 349 women) records with CIED implantations were included from Japan and the USA, respectively. Proportion of women in defibrillator recipients was lower in Japan than in the USA (ICD, 21% vs 28%, p<0.001; CRTD, 24% vs 29%, p<0.001). Length of stay after CIED implantation was longer in Japan than in the USA for all device types (conventional pacemaker, 8(7-11) vs 1 (1-3) days, p<0.001; leadless pacemaker, 5 (3-9) vs 2 (1-5) days, p<0.001; ICD, 8 (7-11) vs 1 (1-3) days, p<0.001, CRTP, 9 (7-13) vs 2 (1-4) days, p<0.001; CRTD, 9 (8-14) vs 2 (1-4) days, p<0.001). In-hospital mortality after CIED implantation was similar between Japan and the USA ((OR) (95% CI), conventional pacemaker 0.58 (0.83 to 1.004); ICD 0.77 (0.57 to 1.03); CRTP 0.85 (0.51 to 1.44); CRTD 1.11 (0.81 to 1.51)), except that after leadless pacemaker implantation in Japan was lower than that in the USA (0.32 (0.23 to 0.43)). 30-day readmission rates were lower in Japan than in the USA for all device types (conventional pacemaker 0.55 (0.53 to 0.57); leadless pacemaker 0.50 (0.43 to 0.58); ICD 0.54 (0.49 to 0.58); CRTP 0.51 (0.42 to 0.62); CRTD 0.57 (0.51 to 0.64)). CONCLUSIONS International variations in patient characteristics, practice and outcomes were observed. In-hospital mortality after CIED implantation was similar between Japan and the USA, except in cases of leadless pacemaker recipients.
Collapse
Affiliation(s)
- Reina Tonegawa-Kuji
- Department of Medical and Health Information Management, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Yuko Y Inoue
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Michikazu Nakai
- Department of Medical and Health Information Management, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Koshiro Kanaoka
- Department of Medical and Health Information Management, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Yoko Sumita
- Department of Medical and Health Information Management, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Yuichiro Miyazaki
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Akinori Wakamiya
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Keiko Shimamoto
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Nobuhiko Ueda
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Kenzaburo Nakajima
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Mitsuru Wada
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Tsukasa Kamakura
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Kenichiro Yamagata
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Kohei Ishibashi
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Koji Miyamoto
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Satoshi Nagase
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Takeshi Aiba
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Yoshihiro Miyamoto
- Department of Medical and Health Information Management, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Yoshitaka Iwanaga
- Department of Medical and Health Information Management, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| | - Kengo Kusano
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
| |
Collapse
|
6
|
Philippon F. Real-World Use of Leadless Pacing: Lessons Learned. Can J Cardiol 2022; 38:1706-1708. [PMID: 36075513 DOI: 10.1016/j.cjca.2022.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 08/29/2022] [Accepted: 09/01/2022] [Indexed: 12/24/2022] Open
Affiliation(s)
- François Philippon
- Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, Québec, Canada.
| |
Collapse
|
7
|
Tonegawa-Kuji R, Kanaoka K, Mori M, Nakai M, Iwanaga Y. Mortality and 30-Day Readmission Rates After Inpatient Leadless Pacemaker Implantation: Insights From a Nationwide Readmissions Database. Can J Cardiol 2022; 38:1697-1705. [PMID: 35963501 DOI: 10.1016/j.cjca.2022.08.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 08/02/2022] [Accepted: 08/07/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND This study aimed to provide real-world data on the rates, trends, and predictors of in-hospital complications and 30-day readmission following leadless pacemaker (LP) implantation. METHODS We analysed leadless and conventional pacemaker implantations with the use of the all-payer, nationally representative Nationwide Readmissions Database from 2017 to 2019. The national trends of in-hospital mortality, in-hospital complications, and 30-day readmission rates after pacemaker implantation were analysed. Mixed-effects multivariable logistic regression analysis was performed to identify factors associated with in-hospital death and 30-day readmission in LP patients. RESULTS A total of 137,732 admissions (age 78 years, IQR 70-85 years, 5986 LP implantations) were analysed. The in-hospital mortality, overall in-hospital complication, and 30-day readmission rates after LP implantations were 5.0%, 16%, and 16%, respectively. In LP recipients, the national estimate of in-hospital mortality declined from 10.9% in the second quarter of 2017 to 4.3% in the fourth quarter of 2019 (P < 0.001). Furthermore, the national estimate of overall complications declined from 20.6% in the second quarter of 2017 to 13.0% in the fourth quarter of 2019 (P < 0.001). In LP recipients, female sex, history of chronic kidney disease, heart failure, and malnutrition were factors associated with in-hospital death. CONCLUSIONS Analysis of the nationally representative claims database from the United States showed in-hospital mortality and complication rates (for LP implantation performed during hospitalisation) of 5.0% and 16%, respectively. Although these rates showed a decreasing trend over time, ongoing surveillance is needed for the safety of LP implantation.
Collapse
Affiliation(s)
- Reina Tonegawa-Kuji
- Department of Medical and Health Information Management, National Cerebral and Cardiovascular Centre, Suita, Japan.
| | - Koshiro Kanaoka
- Department of Medical and Health Information Management, National Cerebral and Cardiovascular Centre, Suita, Japan
| | - Makoto Mori
- Section of Cardiac Surgery, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Michikazu Nakai
- Department of Medical and Health Information Management, National Cerebral and Cardiovascular Centre, Suita, Japan
| | - Yoshitaka Iwanaga
- Department of Medical and Health Information Management, National Cerebral and Cardiovascular Centre, Suita, Japan
| |
Collapse
|
8
|
Ryser A, Schmid T, Bereuter L, Burger J, Reichlin T, Niederhauser T, Haeberlin A. Modulation Scheme Analysis for Low-Power Leadless Pacemaker Synchronization Based on Conductive Intracardiac Communication. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:419-429. [PMID: 35622811 DOI: 10.1109/tbcas.2022.3178444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Conductive intracardiac communication (CIC) has been demonstrated as a promising concept for the synchronization of multi-chamber leadless cardiac pacemakers (LLPMs). To meet the 2-5 μW power budget of a LLPM, highly specialized CIC-transceivers, which make optimal use of the cardiac communication channel, need to be developed. However, a detailed investigation of the optimal communication parameters for CIC-based LLPM synchronization is missing so far. This work analyzes the intracardiac communication performance of two low-power modulation techniques, namely On-Off-Keying (OOK) and Manchester-encoded baseband transmission (BB-MAN), as a function of the transmitted bit-energy. The bit error rate (BER) of a prototype dual-chamber LLPM was determined both in simulation and in-vitro experiments on porcine hearts. A BER of 1e -4 was achieved with a median bit-energy in the range of 3-16 pJ (interquartile range: 4-15 pJ) for data rates from 75-500 kbps and a receiver input noise density of 7 nV/ √{Hz}. Both modulation schemes showed comparable performance, with BB-MAN having a slight bit-energy advantage (1-2 dB at 150-500 kbps) under equalized transceiver characteristics. This study demonstrates that reliable CIC-based LLPM synchronization is feasible at transmitted power levels 10 nW under realistic channel conditions and receiver noise performance. Therefore, modulation techniques such, as BB-MAN or OOK, are preferable over recently proposed alternatives, such as pulse position modulation or conductive impulse signaling, since they can be realized with fewer hardware resources and smaller bandwidth requirements. Ultimately, a baseband communication approach might be favored over OOK, due to the more efficient cardiac signal transmission and reduced transceiver complexity.
Collapse
|
9
|
Haeberlin A, Bartkowiak J, Brugger N, Tanner H, Wan E, Baldinger SH, Seiler J, Madaffari A, Thalmann G, Servatius H, Roten L, Noti F, Reichlin T. Evolution of tricuspid valve regurgitation after implantation of a leadless pacemaker - a single center experience, systematic review and meta-analysis. J Cardiovasc Electrophysiol 2022; 33:1617-1627. [PMID: 35614867 PMCID: PMC9545011 DOI: 10.1111/jce.15565] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 05/12/2022] [Accepted: 05/22/2022] [Indexed: 11/29/2022]
Abstract
Introduction Conventional transvenous pacemaker leads may interfere with the tricuspid valve leaflets, tendinous chords, and papillary muscles, resulting in significant tricuspid valve regurgitation (TR). Leadless pacemakers (LLPMs) theoretically cause less mechanical interference with the tricuspid valve apparatus. However, data on TR after LLPM implantation are sparse and conflicting. Our goal was to investigate the prevalence of significant TR before and after LLPM implantation. Methods Patients who received a leadless LLPM (Micra™ TPS, Medtronic) between May 2016 and May 2021 at our center were included in this observational study if they had at least a pre‐ and postinterventional echocardiogram (TTE). The evolution of TR severity was assessed. Following a systematic literature review on TR evolution after implantation of a LLPM, data were pooled in a random‐effects meta‐analysis. Results We included 69 patients (median age 78 years [interquartile range (IQR) 72–84 years], 26% women). Follow‐up duration between baseline and follow‐up TTE was 11.4 months (IQR 3.5–20.1 months). At follow‐up, overall TR severity was not different compared to baseline (p = .49). Six patients (9%) had new significant TR during follow‐up after LLPM implantation, whereas TR severity improved in seven patients (10%). In the systematic review, we identified seven additional articles that investigated the prevalence of significant TR after LLPM implantation. The meta‐analysis based on 297 patients failed to show a difference in significant TR before and after LLPM implantation (risk ratio 1.22, 95% confidence interval 0.97–1.53, p = .11). Conclusion To date, there is no substantial evidence for a significant change in TR after implantation of a LLPM.
Collapse
Affiliation(s)
- Andreas Haeberlin
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.,Sitem Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Switzerland
| | - Joanna Bartkowiak
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Nicolas Brugger
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Hildegard Tanner
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Elaine Wan
- Div. of Cardiology, Dept. of Medicine, Vagelos College of Physicians and Surgeons, Columbia University, New York
| | - Samuel H Baldinger
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Jens Seiler
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Antonio Madaffari
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Gregor Thalmann
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Helge Servatius
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Laurent Roten
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Fabian Noti
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Tobias Reichlin
- Dept. of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| |
Collapse
|
10
|
Hauser RG, Gornick CC, Abdelhadi RH, Tang CY, Kapphahn‐Bergs M, Casey SA, Okeson BK, Steele EA, Sengupta JD. Leadless pacemaker perforations: Clinical consequences and related device and user problems. J Cardiovasc Electrophysiol 2022; 33:154-159. [PMID: 34953099 PMCID: PMC9305184 DOI: 10.1111/jce.15343] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 11/15/2021] [Accepted: 11/30/2021] [Indexed: 11/27/2022]
Abstract
BACKGROUND Cardiac perforation during leadless pacemaker implantation is more likely to require intervention than perforation by a transvenous lead. This study reports the consequences of Micra pacemaker perforations and related device and operator use problems based on information the manufacturer has submitted to the Food and Drug Administration (FDA). METHODS FDA's Manufacturer and User Facility Device Experience (MAUDE) database was searched for Micra perforations. Data extracted included deaths, major adverse clinical events (MACEs), and device and/or operator use problems. RESULTS Between 2016 and July 2021, 563 perforations were reported within 30 days of implant and resulted in 150 deaths (27%), 499 cardiac tamponades (89%), 64 pericardial effusions (11%), and 146 patients (26%) required emergency surgery. Half of perforations were associated with 139 (25%) device problems, 78 (14%) operator use problems, and 62 (11%) combined device and operator use problems. Inadequate electrical measurements or difficult positioning were the most frequent device problems (n = 129); non-septal implants and perforation of other structures were the most frequent operator use problems (n = 69); a combined operator use and device problem resulted in 62 delivery system perforations. No device or operator use problem was identified for 282 perforations (50%), but they were associated with 78 deaths, 245 tamponades, and 57 emergency surgeries. CONCLUSION The Micra perforations reported in MAUDE are often associated with death and major complications requiring emergency intervention. Device and use problems account for at least half of perforations. Studies are needed to identify who is at risk for a perforation and how MACE can be avoided or mitigated.
Collapse
Affiliation(s)
- Robert G. Hauser
- Heart Rhythm Science CenterMinneapolis Heart Institute FoundationMinneapolisMinnesotaUSA
| | - Charles C. Gornick
- Heart Rhythm Science CenterMinneapolis Heart Institute FoundationMinneapolisMinnesotaUSA
| | - Raed H. Abdelhadi
- Heart Rhythm Science CenterMinneapolis Heart Institute FoundationMinneapolisMinnesotaUSA
| | - Chuen Y. Tang
- Heart Rhythm Science CenterMinneapolis Heart Institute FoundationMinneapolisMinnesotaUSA
| | - Melanie Kapphahn‐Bergs
- Heart Rhythm Science CenterMinneapolis Heart Institute FoundationMinneapolisMinnesotaUSA
| | - Susan A. Casey
- Heart Rhythm Science CenterMinneapolis Heart Institute FoundationMinneapolisMinnesotaUSA
| | - Brynn K. Okeson
- Heart Rhythm Science CenterMinneapolis Heart Institute FoundationMinneapolisMinnesotaUSA
| | - Elizabeth A. Steele
- Heart Rhythm Science CenterMinneapolis Heart Institute FoundationMinneapolisMinnesotaUSA
| | - Jay D. Sengupta
- Heart Rhythm Science CenterMinneapolis Heart Institute FoundationMinneapolisMinnesotaUSA
| |
Collapse
|
11
|
Neugebauer F, Noti F, van Gool S, Roten L, Baldinger SH, Seiler J, Madaffari A, Servatius H, Ryser A, Tanner H, Reichlin T, Haeberlin A. Leadless atrio-ventricular synchronous pacing in an outpatient setting - early lessons learned on factors affecting atrio-ventricular synchrony. Heart Rhythm 2021; 19:748-756. [PMID: 34971817 DOI: 10.1016/j.hrthm.2021.12.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Revised: 12/14/2021] [Accepted: 12/17/2021] [Indexed: 11/19/2022]
Abstract
BACKGROUND Leadless pacemakers (PMs) capable of atrio-ventricular (AV) synchronous pacing have recently been introduced. Initial feasibility studies were promising, but limited to just a few minutes of AV synchronous pacing. Real-world long-term data on AV synchrony and programming adjustments affecting AV synchrony in outpatients are lacking. OBJECTIVE To investigate AV synchrony and influences of PM programming adjustments in outpatients with leadless VDD PMs. METHODS All patients who received a leadless VDD PM (Micra™ AV, Medtronic, US) between 07/2020 and 05/2021 at our center were included in this observational study. AV synchrony was assessed repeatedly postoperatively and during follow-up using Holter ECG recordings. AV synchrony was defined as a QRS complex preceded by a p-wave within 300ms. The impact of programming changes during follow-up on AV synchrony was studied. RESULTS 816 hours of Holter ECG from 20 outpatients were analyzed. During predominantly paced episodes (≥80% ventricular pacing), median AV synchrony was 91% (IQR 34-100%) when patients had sinus rates 50-80/min. Median AV synchrony was lower when patients had sinus rates >80/min (33%, IQR 29-46%, p<0.001). During a stepwise optimization protocol, AV synchrony could be improved (p<0.038). Multivariate analysis showed that a shorter maximum A3 window end (p<0.001), a lower A3 threshold (p=0.046), and minimum A4 threshold (p<0.001) improved AV synchrony. CONCLUSION Successful VDD pacing in the outpatient setting during higher sinus rates is more difficult to achieve than can be presumed based on the initial feasibility studies. The devices often require multiple reprogramming to maximize AV sequential pacing.
Collapse
Affiliation(s)
- Felix Neugebauer
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Sitem Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Bern, Switzerland
| | - Fabian Noti
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Stephan van Gool
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Laurent Roten
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Samuel H Baldinger
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Jens Seiler
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Antonio Madaffari
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Helge Servatius
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Adrian Ryser
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Sitem Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Bern, Switzerland
| | - Hildegard Tanner
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Tobias Reichlin
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Andreas Haeberlin
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Sitem Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Bern, Switzerland.
| |
Collapse
|
12
|
Darlington D, Brown P, Carvalho V, Bourne H, Mayer J, Jones N, Walker V, Siddiqui S, Patwala A, Kwok CS. Efficacy and safety of leadless pacemaker: A systematic review, pooled analysis and meta-analysis. Indian Pacing Electrophysiol J 2021; 22:77-86. [PMID: 34922032 PMCID: PMC8981159 DOI: 10.1016/j.ipej.2021.12.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 11/17/2021] [Accepted: 12/14/2021] [Indexed: 11/26/2022] Open
Abstract
Background Leadless pacemakers have been designed as an alternative to transvenous systems which avoid some of the complications associated with transvenous devices. We aim to perform a systematic review of the literature to report the safety and efficacy findings of leadless pacemakers. Methods We searched MEDLINE and EMBASE to identify studies reporting the safety, efficacy and outcomes of patients implanted with a leadless pacemaker. The pooled rate of adverse events was determined and random-effects meta-analysis was performed to compare rates of adverse outcomes for leadless compared to transvenous pacemakers. Results A total of 18 studies were included with 2496 patients implanted with a leadless pacemaker and success rates range between 95.5 and 100%. The device or procedure related death rate was 0.3% while any complication and pericardial tamponade occurred in 3.1% and 1.4% of patients, respectively. Other complications such as pericardial effusion, device dislodgement, device revision, device malfunction, access site complications and infection occurred in less than 1% of patients. Meta-analysis of four studies suggests that there was no difference in hematoma (RR 0.67 95%CI 0.21–2.18, 3 studies), pericardial effusion (RR 0.59 95%CI 0.15–2.25, 3 studies), device dislocation (RR 0.33 95%CI 0.06–1.74, 3 studies), any complication (RR 0.44 95%CI 0.17–1.09, 4 studies) and death (RR 0.45 95%CI 0.15–1.35, 2 studies) comparing patients who received leadless and transvenous pacemakers. Conclusion Leadless pacemakers are safe and effective for patients who have an indication for single chamber ventricular pacing and the findings appear to be comparable to transvenous pacemakers.
Collapse
Affiliation(s)
- Daniel Darlington
- Department of Cardiology, Royal Stoke University Hospital, Stoke-on-Trent, UK.
| | - Philip Brown
- Department of Cardiology, Royal Stoke University Hospital, Stoke-on-Trent, UK
| | - Vanessa Carvalho
- Department of Cardiology, Royal Stoke University Hospital, Stoke-on-Trent, UK
| | - Hayley Bourne
- Department of Cardiology, Royal Stoke University Hospital, Stoke-on-Trent, UK
| | - Joseph Mayer
- Department of Cardiology, Royal Stoke University Hospital, Stoke-on-Trent, UK
| | - Nathen Jones
- Department of Cardiology, Royal Stoke University Hospital, Stoke-on-Trent, UK
| | - Vincent Walker
- Department of Cardiology, Royal Stoke University Hospital, Stoke-on-Trent, UK
| | - Shoaib Siddiqui
- Department of Cardiology, Royal Stoke University Hospital, Stoke-on-Trent, UK
| | - Ashish Patwala
- Department of Cardiology, Royal Stoke University Hospital, Stoke-on-Trent, UK
| | - Chun Shing Kwok
- Department of Cardiology, Royal Stoke University Hospital, Stoke-on-Trent, UK; School of Medicine, Keele University, Keele, UK
| |
Collapse
|
13
|
Zurbuchen A, Pfenniger A, Omari S, Reichlin T, Vogel R, Haeberlin A. A Robot Mimicking Heart Motions: An Ex-Vivo Test Approach for Cardiac Devices. Cardiovasc Eng Technol 2021; 13:207-218. [PMID: 34409579 PMCID: PMC9114091 DOI: 10.1007/s13239-021-00566-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Accepted: 07/12/2021] [Indexed: 11/25/2022]
Abstract
Purpose The pre-clinical testing of cardiovascular implants gains increasing attention due to the complexity of novel implants and new medical device regulations. It often relies on large animal experiments that are afflicted with ethical and methodical challenges. Thus, a method for simulating physiological heart motions is desired but lacking so far. Methods We developed a robotic platform that allows simulating the trajectory of any point of the heart (one at a time) in six degrees of freedom. It uses heart motion trajectories acquired from cardiac magnetic resonance imaging or accelero-meter data. The rotations of the six motors are calculated based on the input trajectory. A closed-loop controller drives the platform and a graphical user interface monitors the functioning and accuracy of the robot using encoder data. Results The robotic platform can mimic physiological heart motions from large animals and humans. It offers a spherical work envelope with a radius of 29 mm, maximum acceleration of 20 m/s2 and maximum deflection of ±19° along all axes. The absolute mean positioning error in x-, y- and z-direction is 0.21 ±0.06, 0.31 ±0.11 and 0.17 ±0.12 mm, respectively. The absolute mean orientation error around x-, y- and z-axis (roll, pitch and yaw) is 0.24 ±0.18°, 0.23 ±0.13° and 0.18 ±0.18°, respectively. Conclusion The novel robotic approach allows reproducing heart motions with high accuracy and repeatability. This may benefit the device development process and allows re-using previously acquired heart motion data repeatedly, thus avoiding animal trials. Supplementary Information The online version contains supplementary material available at 10.1007/s13239-021-00566-3.
Collapse
Affiliation(s)
- Adrian Zurbuchen
- Department of Cardiology, Bern University Hospital, University of Bern, Freiburgstrassse 3, 3010, Bern, Switzerland.
- sitem Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Bern, Switzerland.
- ARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland.
| | - Aloïs Pfenniger
- ARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland
- Sonceboz SA, Sonceboz, Switzerland
| | - Sammy Omari
- Department of Cardiology, Bern University Hospital, University of Bern, Freiburgstrassse 3, 3010, Bern, Switzerland
- ARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland
- Lyft Inc., San Francisco, CA, USA
| | - Tobias Reichlin
- Department of Cardiology, Bern University Hospital, University of Bern, Freiburgstrassse 3, 3010, Bern, Switzerland
| | - Rolf Vogel
- Department of Cardiology, Bürgerspital Solothurn, Solothurn, Switzerland
| | - Andreas Haeberlin
- Department of Cardiology, Bern University Hospital, University of Bern, Freiburgstrassse 3, 3010, Bern, Switzerland.
- sitem Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Bern, Switzerland.
- ARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland.
| |
Collapse
|
14
|
Ngo L, Nour D, Denman RA, Walters TE, Haqqani HM, Woodman RJ, Ranasinghe I. Safety and Efficacy of Leadless Pacemakers: A Systematic Review and Meta-Analysis. J Am Heart Assoc 2021; 10:e019212. [PMID: 34169736 PMCID: PMC8403316 DOI: 10.1161/jaha.120.019212] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background Leadless pacemaker is a novel technology, and evidence supporting its use is uncertain. We performed a systematic review and meta-analysis to examine the safety and efficacy of leadless pacemakers implanted in the right ventricle. Methods and Results We searched PubMed and Embase for studies published before June 6, 2020. The primary safety outcome was major complications, whereas the primary efficacy end point was acceptable pacing capture threshold (≤2 V). Pooled estimates were calculated using the Freedman-Tukey double arcsine transformation. Of 1281 records screened, we identified 36 observational studies of Nanostim and Micra leadless pacemakers, with most (69.4%) reporting outcomes for the Micra. For Micra, the pooled incidence of complications at 90 days (n=1608) was 0.46% (95% CI, 0.08%-1.05%) and at 1 year (n=3194) was 1.77% (95% CI, 0.76%-3.07%). In 5 studies with up to 1-year follow-up, Micra was associated with 51% lower odds of complications compared with transvenous pacemakers (3.30% versus 7.43%; odds ratio [OR], 0.49; 95% CI, 0.34-0.70). At 1 year, 98.96% (95% CI, 97.26%-99.94%) of 1376 patients implanted with Micra had good pacing capture thresholds. For Nanostim, the reported complication incidence ranged from 6.06% to 23.54% at 90 days and 5.33% to 6.67% at 1 year, with 90% to 100% having good pacing capture thresholds at 1 year (pooled result not estimated because of the low number of studies). Conclusions Most studies report outcomes for the Micra, which is associated with a low risk of complications and good electrical performance up to 1-year after implantation. Further data from randomized controlled trials are needed to support the widespread adoption of these devices in clinical practice.
Collapse
Affiliation(s)
- Linh Ngo
- School of Clinical Medicine The University of Queensland Brisbane QLD Australia.,Department of Cardiology The Prince Charles Hospital Brisbane QLD Australia.,Cardiovascular Centre E Hospital Hanoi Vietnam
| | - Daniel Nour
- Department of Cardiology The Prince Charles Hospital Brisbane QLD Australia
| | - Russell A Denman
- Department of Cardiology The Prince Charles Hospital Brisbane QLD Australia
| | - Tomos E Walters
- School of Clinical Medicine The University of Queensland Brisbane QLD Australia.,St Vincent's Private Hospital Northside Brisbane QLD Australia
| | - Haris M Haqqani
- School of Clinical Medicine The University of Queensland Brisbane QLD Australia.,Department of Cardiology The Prince Charles Hospital Brisbane QLD Australia
| | - Richard J Woodman
- Flinders Centre for Epidemiology and Biostatistics Flinders University Adelaide SA Australia
| | - Isuru Ranasinghe
- School of Clinical Medicine The University of Queensland Brisbane QLD Australia.,Department of Cardiology The Prince Charles Hospital Brisbane QLD Australia
| |
Collapse
|
15
|
Franzina N, Zurbuchen A, Zumbrunnen A, Niederhauser T, Reichlin T, Burger J, Haeberlin A. A miniaturized endocardial electromagnetic energy harvester for leadless cardiac pacemakers. PLoS One 2020; 15:e0239667. [PMID: 32986751 PMCID: PMC7521684 DOI: 10.1371/journal.pone.0239667] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 09/11/2020] [Indexed: 11/19/2022] Open
Abstract
Life expectancy of contemporary cardiac pacemakers is limited due to the use of an internal primary battery. Repeated device replacement interventions are necessary, which leads to an elevated risk for patients and an increase of health care costs. The aim of our study is to investigate the feasibility of powering an endocardial pacemaker by converting a minimal amount of the heart's kinetic energy into electric energy. The intrinsic cardiac muscle activity makes it an ideal candidate as continuous source of energy for endocardial pacemakers. For this reason, we developed a prototype able to generate enough power to supply a pacing circuit at different heart rates. The prototype consists of a mass imbalance that drives an electromagnetic generator while oscillating. We developed a mathematical model to estimate the amount of energy harvested from the right ventricle. Finally, the implemented prototype was successfully tested during in-vitro and in-vivo experiments.
Collapse
Affiliation(s)
- Nicolas Franzina
- Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland
- Sitem Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Bern, Switzerland
| | - Adrian Zurbuchen
- Sitem Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Bern, Switzerland
| | - Andreas Zumbrunnen
- Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland
- ARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland
| | - Thomas Niederhauser
- Institute for Human Centered Engineering, Bern University of Applied Sciences, Biel, Switzerland
| | - Tobias Reichlin
- Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Juergen Burger
- Sitem Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Bern, Switzerland
| | - Andreas Haeberlin
- Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland
- Sitem Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Bern, Switzerland
- ARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland
| |
Collapse
|