1
|
Tam MTK, Cheng YW, Chan JYS, Chan CP, Au ACK, Fan KWS, Chim TMY, Kwok WY, Fong FK, Lai A, Tan GM, Yan BP. Aveir VR real-world performance and chronic pacing threshold prediction using mapping and fixation electrical data. Europace 2024; 26:euae051. [PMID: 38457487 PMCID: PMC10923508 DOI: 10.1093/europace/euae051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Accepted: 02/14/2024] [Indexed: 03/10/2024] Open
Abstract
AIMS Aveir VR performance and predictors for its pacing threshold (PCT) in a real-world cohort were investigated. METHODS Electrical measurements at various stages of an Aveir VR implant were prospectively collected. Predictors for 3-month PCT were studied. A retrospective cohort of consecutive 139 Micra implants was used to compare the PCT evolution. High PCT was defined as ≥1.5 V, using a pulse width of 0.4 ms for Aveir and 0.24 ms for Micra. Excellent PCT was defined as ≤0.5 V at the respective pulse width. RESULTS Among the 123 consecutive Aveir VR implant attempts, 122 (99.2%) were successful. The majority were of advanced age (mean 79.7) and small body size (mean BSA 1.60). Two patients (1.6%) experienced complications, including one pericardial effusion after device reposition and one intraoperative device dislodgement. Eighty-eight patients reached a 3-month follow-up. Aveir 3-month PCT was correlated with impedance at mapping (P = 0.015), tether mode (P < 0.001), end-of-procedure (P < 0.001), and mapping PCT (P = 0.035), but not with PCTs after fixation (P > 0.05). Tether mode impedance >470 ohms had 88% sensitivity and 71% specificity in predicting excellent 3-month PCT. Although it is more common for Aveir to have high PCT at end of procedure (11.5% for Aveir and 2.2% for Micra, P = 0.004), the rate at 3 months was similar (2.3% for Aveir and 3.1% for Micra, P = 1.000). CONCLUSION Aveir VR demonstrated satisfactory performance in this high-risk cohort. Pacing thresholds tend to improve to a greater extent than Micra after implantation. The PCT after fixation, even after a waiting period, has limited predictive value for the chronic threshold. Low-mapping PCT and high intraoperative impedance predict chronic low PCT.
Collapse
Affiliation(s)
- Mark T K Tam
- Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, NT, Hong Kong
| | - Yuet-Wong Cheng
- Division of Cardiology, Department of Medicine, Queen Elizabeth Hospital, 30 Gascoigne Road, KLN, Hong Kong
| | - Joseph Y S Chan
- Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, NT, Hong Kong
| | - Chin-Pang Chan
- Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, NT, Hong Kong
| | - Alex C K Au
- Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, NT, Hong Kong
| | - Katie W S Fan
- Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, NT, Hong Kong
| | - Thomas M Y Chim
- Division of Cardiology, Department of Medicine, Queen Elizabeth Hospital, 30 Gascoigne Road, KLN, Hong Kong
| | - Wan-Ying Kwok
- Division of Cardiology, Department of Medicine, Queen Elizabeth Hospital, 30 Gascoigne Road, KLN, Hong Kong
| | - Fuk-Kei Fong
- Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, NT, Hong Kong
| | - Angel Lai
- Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, NT, Hong Kong
| | - Guang-Ming Tan
- Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, NT, Hong Kong
| | - Bryan P Yan
- Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, NT, Hong Kong
| |
Collapse
|