1
|
Madsen S, Kjaerulff MLG, Ejlersen JA, Ranghøj Nielsen BR, Jakobsen L, Sörensen J, Tolbod LP, Gormsen LC. Guiding early revascularization using [15O]H2O positron emission tomography myocardial perfusion imaging: impact of atrial fibrillation. Eur Heart J Cardiovasc Imaging 2024; 25:958-967. [PMID: 38376457 DOI: 10.1093/ehjci/jeae043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 12/20/2023] [Accepted: 02/03/2024] [Indexed: 02/21/2024] Open
Abstract
AIMS Myocardial perfusion imaging (MPI) using [15O]H2O positron emission tomography (PET) is used to guide the selection of patients with angina for invasive angiography and possible revascularization. Our study evaluated (i) whether atrial fibrillation (AF) reduces global hyperaemic myocardial blood flow (MBF) and (ii) whether [15O]H2O PET MPI effectively guides revascularization procedures for patients with ongoing AF. METHODS AND RESULTS We prospectively recruited 346 patients with angina and persistent or paroxysmal AF referred for baseline/hyperaemic [15O]H2O PET MPI. The primary outcome was revascularization within 3 months of MPI. In the analyses, patients were divided into four groups based on whether they had ongoing AF or sinus rhythm (SR) and whether they had previously documented coronary artery disease (CAD) or not. Thus, four groups were compared: SR-noCAD, AF-noCAD, SR-CAD, and AF-CAD. Hyperaemic MBF was affected by both ongoing AF and prior CAD [MBF (mL/min/g): 2.82 (SR-noCAD) vs. 2.12 (AF-noCAD) vs. 2.22 (SR-CAD) vs. 1.80 (AF-CAD), two-way analysis of variance P < 0.0001]. In multiple linear regression, ongoing AF was independently associated with reduced hyperaemic MBF. Every 0.1 mL/min/g decrease in hyperaemic MBF was associated with a 23% increase in odds of early revascularization. Receiver operating characteristic (ROC) analysis of vessel-specific hyperaemic MBF to predict early revascularization yielded the following areas under the ROC curve: SR-noCAD: 0.95 (P < 0.0001); AF-noCAD: 0.79 (P < 0.0001); SR-CAD: 0.78 (P < 0.0001); and AF-CAD: 0.88 (P < 0.0001). CONCLUSION Ongoing AF is associated with 19-25% reduced global hyperaemic MBF as measured by [15O]H2O MPI PET. Regardless, vessel-specific hyperaemic MBF still predicts early revascularization in patients with AF.
Collapse
Affiliation(s)
- Simon Madsen
- Department of Nuclear Medicine & PET-Centre, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, Aarhus N DK-8200, Denmark
| | - Mette Louise Gram Kjaerulff
- Department of Nuclear Medicine & PET-Centre, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, Aarhus N DK-8200, Denmark
| | - June Anita Ejlersen
- Department of Physiology and Nuclear Medicine, Regional Hospital Viborg, Viborg, Denmark
| | | | - Lars Jakobsen
- Department of Cardiology, Aarhus University Hospital, Aarhus N, Denmark
| | - Jens Sörensen
- Department of Nuclear Medicine & PET-Centre, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, Aarhus N DK-8200, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard, 998200 Aarhus N, Denmark
| | - Lars Poulsen Tolbod
- Department of Nuclear Medicine & PET-Centre, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, Aarhus N DK-8200, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard, 998200 Aarhus N, Denmark
| | - Lars Christian Gormsen
- Department of Nuclear Medicine & PET-Centre, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, Aarhus N DK-8200, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard, 998200 Aarhus N, Denmark
| |
Collapse
|
2
|
Takahashi M, Arai T, Kimura T, Hojo R, Hiraoka M, Fukamizu S. Relationship between coronary blood flow and improvement of cardiac function after catheter ablation for persistent atrial fibrillation. J Interv Card Electrophysiol 2023; 66:2063-2070. [PMID: 37043092 DOI: 10.1007/s10840-023-01542-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 03/27/2023] [Indexed: 04/13/2023]
Abstract
BACKGROUND The relationship between coronary blood flow during atrial fibrillation (AF) and improvement of cardiac function after catheter ablation (CA) for persistent AF (PeAF) is not prominent; this study was conducted to evaluate this relationship. METHODS This was a retrospective case-control study. Eighty-five patients with PeAF (resting heart rate < 100 bpm) and heart failure with reduced ejection fraction (left ventricular ejection fraction (LVEF) < 40%) who had undergone coronary angiography within 1 week before CA were included. All patients could maintain a sinus rhythm for > 6 months after CA. The primary outcome was improvement of cardiac function with an LVEF cutoff value of > 50% during sinus rhythm 6 months after CA. RESULTS In the LVEF improvement group (N = 57), patients were younger, with a higher baseline diastolic blood pressure and lower baseline brain natriuretic peptide level than the no LVEF improvement group (N = 28). Heart rate at baseline and 6 months after CA and AF duration did not differ between the two groups. Thrombolysis in myocardial infarction frame count parameters was significantly higher in the LVEF improvement (P < 0.001) than in the no LVEF improvement group. Multivariate logistic regression analysis revealed mean thrombolysis in myocardial infarction frame count as an independent factor for LVEF improvement (odds ratio, 1.72 (95% confidence interval 1.17-2.54); P = 0.006). CONCLUSION Coronary blood flow in patients with PeAF is strongly associated with improved left ventricular systolic function after the restoration of sinus rhythm by CA for PeAF and heart failure with reduced ejection fraction.
Collapse
Affiliation(s)
- Masao Takahashi
- Department of Cardiology, Tokyo Metropolitan Hiroo Hospital, Tokyo, Japan.
| | - Tomoyuki Arai
- Department of Cardiology, Tokyo Metropolitan Hiroo Hospital, Tokyo, Japan
| | - Takashi Kimura
- Department of Cardiology, Tokyo Metropolitan Hiroo Hospital, Tokyo, Japan
| | - Rintaro Hojo
- Department of Cardiology, Tokyo Metropolitan Hiroo Hospital, Tokyo, Japan
| | | | - Seiji Fukamizu
- Department of Cardiology, Tokyo Metropolitan Hiroo Hospital, Tokyo, Japan
| |
Collapse
|
3
|
Berruezo A, Penela D, Jáuregui B, de Asmundis C, Peretto G, Marrouche N, Trayanova N, de Chillou C. Twenty-five years of research in cardiac imaging in electrophysiology procedures for atrial and ventricular arrhythmias. Europace 2023; 25:euad183. [PMID: 37622578 PMCID: PMC10450789 DOI: 10.1093/europace/euad183] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 06/14/2023] [Indexed: 08/26/2023] Open
Abstract
Catheter ablation is nowadays considered the treatment of choice for numerous cardiac arrhythmias in different clinical scenarios. Fluoroscopy has traditionally been the primary imaging modality for catheter ablation, providing real-time visualization of catheter navigation. However, its limitations, such as inadequate soft tissue visualization and exposure to ionizing radiation, have prompted the integration of alternative imaging modalities. Over the years, advancements in imaging techniques have played a pivotal role in enhancing the safety, efficacy, and efficiency of catheter ablation procedures. This manuscript aims to explore the utility of imaging, including electroanatomical mapping, cardiac computed tomography, echocardiography, cardiac magnetic resonance, and nuclear cardiology exams, in helping electrophysiology procedures. These techniques enable accurate anatomical guidance, identification of critical structures and substrates, and real-time monitoring of complications, ultimately enhancing procedural safety and success rates. Incorporating advanced imaging technologies into routine clinical practice has the potential to further improve clinical outcomes of catheter ablation procedures and pave the way for more personalized and precise ablation therapies in the future.
Collapse
Affiliation(s)
- Antonio Berruezo
- Arrhythmia Unit, Teknon Medical Centre, Carrer de Vilana, 12, 08022 Barcelona, Spain
| | - Diego Penela
- Arrhythmia Unit, Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano Milan, Italy
| | - Beatriz Jáuregui
- Arrhythmia Unit - Miguel Servet University Hospital, P.º de Isabel la Católica, 1-3, 50009 Zaragoza, Spain
| | - Carlo de Asmundis
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Blvd Géneral Jacques 137, 1050 Ixelles, Brussels, Belgium
| | - Giovanni Peretto
- Arrhythmia Unit, Ospedale San Raffaele Hospital, Via Olgettina, 60, 20132 Milan, Italy
| | - Nassir Marrouche
- Department of Cardiology, Tulane University School of Medicine, 1430 Tulane Ave, New Orleans, LA 70112, USA
| | - Natalia Trayanova
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
- Department of Applied Math and Statistics, Johns Hopkins University, Baltimore, MD 21218, USA
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Christian de Chillou
- INSERM IADI U1254, University Hospital Nancy, University of Lorraine, 29 Av. du Maréchal de Lattre de Tassigny, 54000 Nancy, France
| |
Collapse
|
4
|
Pezel T, Sanguineti F, Kinnel M, Landon V, Toupin S, Unterseeh T, Louvard Y, Champagne S, Morice MC, Hovasse T, Garot P, Garot J. Feasibility and Prognostic Value of Vasodilator Stress Perfusion CMR in Patients With Atrial Fibrillation. JACC Cardiovasc Imaging 2020; 14:379-389. [PMID: 33129729 DOI: 10.1016/j.jcmg.2020.07.041] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 07/17/2020] [Accepted: 07/29/2020] [Indexed: 01/27/2023]
Abstract
OBJECTIVES The aim of this study was to assess the feasibility and prognostic value of vasodilator stress perfusion cardiovascular magnetic resonance (CMR) in patients with atrial fibrillation (AF). BACKGROUND Because most studies have excluded arrhythmic patients, the prognostic value of stress perfusion CMR in patients with AF is unknown. METHODS Between 2008 and 2018, consecutive patients with suspected or stable chronic coronary artery disease and AF referred for vasodilator stress perfusion CMR were included and followed for the occurrence of major adverse cardiovascular event(s) (MACE), defined as cardiovascular death or nonfatal myocardial infarction. The diagnosis of AF was defined by 12-lead electrocardiography before and after CMR. Univariate and multivariate Cox regressions were performed to determine the prognostic value of inducible ischemia or late gadolinium enhancement (LGE) by CMR. RESULTS Of 639 patients (mean age 72 ± 9 years, 77% men), 602 (94%) completed the CMR protocol, and 538 (89%) completed follow-up (median 5.1 years); 80 had MACE. Using Kaplan-Meier analysis, the presence of ischemia (hazard ratio [HR]: 7.56; 95% confidence interval [CI]: 4.86 to 11.80) or LGE (HR: 2.41; 95% CI: 1.55 to 3.74) was associated with the occurrence of MACE (p < 0.001 for both). In a multivariate Cox regression including clinical and CMR indexes, the presence of ischemia (HR: 5.98; 95% CI: 3.68 to 9.73) or LGE (HR: 2.61; 95% CI: 1.89 to 3.60) was an independent predictor of MACE (p < 0.001 for both). CONCLUSIONS In patients with AF, stress perfusion CMR is feasible and has good discriminative prognostic value to predict the occurrence of MACE.
Collapse
Affiliation(s)
- Théo Pezel
- Institut Cardiovasculaire Paris Sud, Cardiovascular Magnetic Resonance Laboratory, Hôpital Privé Jacques CARTIER, Ramsay Santé, Massy, France; Division of Cardiology, Johns Hopkins University, Baltimore, Maryland
| | - Francesca Sanguineti
- Institut Cardiovasculaire Paris Sud, Cardiovascular Magnetic Resonance Laboratory, Hôpital Privé Jacques CARTIER, Ramsay Santé, Massy, France
| | - Marine Kinnel
- Institut Cardiovasculaire Paris Sud, Cardiovascular Magnetic Resonance Laboratory, Hôpital Privé Jacques CARTIER, Ramsay Santé, Massy, France
| | - Valentin Landon
- Institut Cardiovasculaire Paris Sud, Cardiovascular Magnetic Resonance Laboratory, Hôpital Privé Jacques CARTIER, Ramsay Santé, Massy, France
| | | | - Thierry Unterseeh
- Institut Cardiovasculaire Paris Sud, Cardiovascular Magnetic Resonance Laboratory, Hôpital Privé Jacques CARTIER, Ramsay Santé, Massy, France
| | - Yves Louvard
- Institut Cardiovasculaire Paris Sud, Cardiovascular Magnetic Resonance Laboratory, Hôpital Privé Jacques CARTIER, Ramsay Santé, Massy, France
| | - Stéphane Champagne
- Institut Cardiovasculaire Paris Sud, Cardiovascular Magnetic Resonance Laboratory, Hôpital Privé Jacques CARTIER, Ramsay Santé, Massy, France
| | - Marie Claude Morice
- Institut Cardiovasculaire Paris Sud, Cardiovascular Magnetic Resonance Laboratory, Hôpital Privé Jacques CARTIER, Ramsay Santé, Massy, France
| | - Thomas Hovasse
- Institut Cardiovasculaire Paris Sud, Cardiovascular Magnetic Resonance Laboratory, Hôpital Privé Jacques CARTIER, Ramsay Santé, Massy, France
| | - Philippe Garot
- Institut Cardiovasculaire Paris Sud, Cardiovascular Magnetic Resonance Laboratory, Hôpital Privé Jacques CARTIER, Ramsay Santé, Massy, France
| | - Jérôme Garot
- Institut Cardiovasculaire Paris Sud, Cardiovascular Magnetic Resonance Laboratory, Hôpital Privé Jacques CARTIER, Ramsay Santé, Massy, France.
| |
Collapse
|
5
|
Delgado V, Di Biase L, Leung M, Romero J, Tops LF, Casadei B, Marrouche N, Bax JJ. Structure and Function of the Left Atrium and Left Atrial Appendage. J Am Coll Cardiol 2017; 70:3157-3172. [DOI: 10.1016/j.jacc.2017.10.063] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2017] [Accepted: 10/22/2017] [Indexed: 12/12/2022]
|
6
|
Rapid rest/stress regadenoson ungated perfusion CMR for detection of coronary artery disease in patients with atrial fibrillation. Int J Cardiovasc Imaging 2017; 33:1781-1788. [PMID: 28528431 DOI: 10.1007/s10554-017-1168-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2017] [Accepted: 05/15/2017] [Indexed: 12/16/2022]
Abstract
Cardiovascular magnetic resonance (CMR) perfusion has been established as a useful imaging modality for the detection of coronary artery disease (CAD). However, there are several limitations when applying standard, ECG-gated stress/rest perfusion CMR to patients with atrial fibrillation (AF). In this study we investigate an approach with no ECG gating and a rapid rest/stress perfusion protocol to determine its accuracy for detection of CAD in patients with AF. 26 patients with AF underwent a rapid rest/regadenoson stress CMR perfusion imaging protocol, and all patients had X-ray coronary angiography. An ungated radial myocardial perfusion sequence was used. Imaging protocol included: rest perfusion image acquisition, followed nearly immediately by administration of regadenoson to induce hyperemia, 60 s wait, and stress image acquisition. CMR perfusion images were interpreted by three blinded readers as normal or abnormal. Diagnostic accuracy was evaluated by comparison to X-ray angiography. 21 of the CMR rest/stress perfusion scans were negative, and 5 were positive by angiography criteria. Majority results of the ungated datasets from all of the readers showed a sensitivity, specificity and accuracy of 80, 100 and 96%, respectively, for detection of CAD. An ungated, rapid rest/stress regadenoson perfusion CMR protocol appears to be useful for the diagnosis of obstructive CAD in patients with AF.
Collapse
|
7
|
Alghamry A, Hanna J, Pelecanos A, Kyranis S, Khelgi V, O'Rourke P, Carroll O, Oxenford C, Rangaswamaiah S, Tan C. Predictors of significant coronary artery disease in atrial fibrillation: Are cardiac troponins a useful measure. Int J Cardiol 2016; 223:744-749. [PMID: 27573599 DOI: 10.1016/j.ijcard.2016.08.267] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2016] [Accepted: 08/16/2016] [Indexed: 11/26/2022]
Abstract
BACKGROUND Cardiac Troponin I (cTnI) is frequently measured in patients presenting with symptomatic atrial fibrillation (AF). The significance of elevated cTnI levels in this patient cohort is unclear. We investigated the value of cTnI elevation in this setting and whether it is predictive for significant coronary artery disease (sCAD). METHODS We conducted a retrospective, single-center, case-control study of 231 patients who presented with symptomatic AF to The Prince Charles Hospital emergency department, Brisbane, Australia between 2006 and 2014. Patients who underwent serial cTnI testing and assessment for CAD were included. Clinical variables that are known to predict CAD and could potentially predict cTnI elevation were collected. Binary logistic regression was performed to identify predictors of sCAD and cTnI elevation. RESULTS Cardiac Troponin I elevation above standard cut off was not predictive for sCAD after adjustment for other predictors (OR 1.62, 95% CI 0.79-3.32. p=0.19). However, the highest cTnI concentration value (cTnI peak) was predictive for sCAD (OR 2.02, 95% CI 1.02-3.97, p=0.04). Dyspnea on presentation (OR 4.52, 95% CI 1.87-10.91, p=0.001), known coronary artery disease (OR 3.44, 95% CI 1.42-8.32, p=0.006), and ST depression on the initial electrocardiogram (OR 2.57, 95% CI 1.11-5.97, p=0.028) predicted sCAD in our cohort, while heart rate on initial presentation was inversely correlated with sCAD (OR 0.99, 95% CI 0.971-1.00, p=0.034). CONCLUSION Troponin elevation is common in patients presenting to hospital with acute symptomatic AF and it is not a reliable indicator for underlying sCAD in this patient cohort. However, cTnI peak was a predictor of significant coronary artery disease.
Collapse
Affiliation(s)
- Alaa Alghamry
- University of Queensland, Australia; Department of Medicine, Redcliffe Hospital, Redcliffe, Australia.
| | - Joseph Hanna
- University of Queensland, Australia; Department of Cardiology, The Prince Charles Hospital, Brisbane, Australia
| | - Anita Pelecanos
- QIMR Berghofer Medical Research Institute, Brisbane, Australia
| | - Stephen Kyranis
- Department of Cardiology, The Prince Charles Hospital, Brisbane, Australia
| | - Vinod Khelgi
- Department of Medicine, Redcliffe Hospital, Redcliffe, Australia
| | - Peter O'Rourke
- QIMR Berghofer Medical Research Institute, Brisbane, Australia
| | - Oran Carroll
- Department of Medicine, Redcliffe Hospital, Redcliffe, Australia
| | - Cassie Oxenford
- Department of Medicine, Redcliffe Hospital, Redcliffe, Australia
| | | | - Christopher Tan
- University of Queensland, Australia; Department of Medicine, Redcliffe Hospital, Redcliffe, Australia
| |
Collapse
|
8
|
Donal E, Lip GYH, Galderisi M, Goette A, Shah D, Marwan M, Lederlin M, Mondillo S, Edvardsen T, Sitges M, Grapsa J, Garbi M, Senior R, Gimelli A, Potpara TS, Van Gelder IC, Gorenek B, Mabo P, Lancellotti P, Kuck KH, Popescu BA, Hindricks G, Habib G, Cosyns B, Delgado V, Haugaa KH, Muraru D, Nieman K, Cohen A. EACVI/EHRA Expert Consensus Document on the role of multi-modality imaging for the evaluation of patients with atrial fibrillation. Eur Heart J Cardiovasc Imaging 2016; 17:355-83. [DOI: 10.1093/ehjci/jev354] [Citation(s) in RCA: 187] [Impact Index Per Article: 23.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
|
9
|
Greulich S, Steubing H, Birkmeier S, Grün S, Bentz K, Sechtem U, Mahrholdt H. Impact of arrhythmia on diagnostic performance of adenosine stress CMR in patients with suspected or known coronary artery disease. J Cardiovasc Magn Reson 2015; 17:94. [PMID: 26541808 PMCID: PMC4635579 DOI: 10.1186/s12968-015-0195-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2015] [Accepted: 10/21/2015] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND The diagnostic performance of adenosine stress cardiovascular magnetic resonance (CMR) in patients with arrhythmias presenting for work-up of suspected or known CAD is largely unknown, since most CMR studies currently available exclude arrhythmic patients from analysis fearing gating problems, or other artifacts will impair image quality. The primary aim of our study was to evaluate the diagnostic performance of adenosine stress CMR for detection of significant coronary stenosis in patients with arrhythmia presenting for 1) work-up of suspected coronary artery disease (CAD), or 2) work-up of ischemia in known CAD. METHODS Patients with arrhythmia referred for work-up of suspected CAD or work-up of ischemia in known CAD undergoing adenosine stress CMR were included if they had coronary angiography within four weeks of CMR. RESULTS One hundred fifty-nine patients were included (n = 64 atrial fibrillation, n = 87 frequent ventricular extrasystoles, n = 8 frequent supraventricular extrasystoles). Of these, n = 72 had suspected CAD, and n = 87 had known CAD. Diagnostic accuracy of the adenosine stress CMR for detection of significant CAD was 73 % for the entire population (sensitivity 72 %, specificity 76 %). Diagnostic accuracy was 75 % (sensitivity 80 %, specificity 74 %) in patients with suspected CAD, and 74 % (sensitivity 71 %, specificity 79 %) in the group with known CAD. For different types of arrhythmia, diagnostic accuracy of CMR was 70 % in the atrial fibrillation group, and 79 % in patients with ventricular extrasystoles. On a per coronary territory analysis, diagnostic accuracy of CMR was 77 % for stenosis of the left and 82 % for stenosis of the right coronary artery. CONCLUSION The present data demonstrates good diagnostic performance of adenosine stress CMR for detection of significant coronary stenosis in patients with arrhythmia presenting for work-up of suspected CAD, or work-up of ischemia in known CAD. This holds true for a per patient, as well as for a per coronary territory analysis.
Collapse
Affiliation(s)
- Simon Greulich
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstrasse 110, 70376, Stuttgart, Germany
| | - Hannah Steubing
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstrasse 110, 70376, Stuttgart, Germany
| | - Stefan Birkmeier
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstrasse 110, 70376, Stuttgart, Germany
| | - Stefan Grün
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstrasse 110, 70376, Stuttgart, Germany
| | - Kerstin Bentz
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstrasse 110, 70376, Stuttgart, Germany
| | - Udo Sechtem
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstrasse 110, 70376, Stuttgart, Germany
| | - Heiko Mahrholdt
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstrasse 110, 70376, Stuttgart, Germany.
| |
Collapse
|
10
|
Gimelli A, Liga R, Startari U, Giorgetti A, Pieraccini L, Marzullo P. Evaluation of ischaemia in patients with atrial fibrillation: impact of stress protocol on myocardial perfusion imaging accuracy. Eur Heart J Cardiovasc Imaging 2015; 16:781-7. [DOI: 10.1093/ehjci/jeu322] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2014] [Accepted: 11/11/2014] [Indexed: 11/13/2022] Open
|
11
|
Looking for Coronary Disease in Patients With Atrial Fibrillation. Can J Cardiol 2014; 30:861-3. [DOI: 10.1016/j.cjca.2014.06.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Accepted: 06/06/2014] [Indexed: 11/18/2022] Open
|
12
|
Elabbassi W, Chowdhury MA, Liska B, Hatala R. Clinical profile and angiographic findings among patients with atrial fibrillation presenting for selective coronary angiography. Health (London) 2014. [DOI: 10.4236/health.2014.61007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
13
|
Luo C, Wu X, Huang Z, Du Z, Hao Y, Hu C, Huang Y, Gao X. Documentation of impaired coronary blood flow by TIMI frame count method in patients with atrial fibrillation. Int J Cardiol 2013; 167:1176-80. [DOI: 10.1016/j.ijcard.2012.03.118] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2011] [Revised: 02/02/2012] [Accepted: 03/12/2012] [Indexed: 11/28/2022]
|
14
|
Harrison A, Adluru G, Damal K, Shaaban AM, Wilson B, Kim D, McGann C, Marrouche NF, DiBella EVR. Rapid ungated myocardial perfusion cardiovascular magnetic resonance: preliminary diagnostic accuracy. J Cardiovasc Magn Reson 2013; 15:26. [PMID: 23537093 PMCID: PMC3744172 DOI: 10.1186/1532-429x-15-26] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2012] [Accepted: 03/08/2013] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Myocardial perfusion cardiovascular magnetic resonance (CMR) is a well-established method for detection of ischemic heart disease. However, ECG gating problems can result in image degradation and non-diagnostic scans, particularly in patients with arrhythmias. METHODS A turboFLASH saturation recovery pulse sequence was used without any ECG triggering. One saturation pulse followed by 4-5 slices of undersampled radial k-space images was acquired rapidly, on the order of 40-50 msec per image. The acquisition of the set of 4-5 slices was continuously repeated approximately 4 times per second. An iterative constrained reconstruction method was used to reconstruct the ungated images. The ungated perfusion images were post-processed into three different sets of images (ungated, self-gated to near systole, and self-gated to near diastole). To test the ungated approach and compare the different processing methods, 8 patients scheduled for coronary angiography underwent stress and rest perfusion imaging with the ungated acquisition. Six patients had a history of atrial fibrillation (AF). Three blinded readers assessed image quality and presence/absence of disease. RESULTS All 8 subjects successfully completed the perfusion CMR protocol and 7/8 underwent coronary angiography. Three patients were in atrial fibrillation during CMR. Overall, the CMR images were of high quality as assessed by the three readers. There was little difference in image quality between patients in AF compared to those in sinus rhythm (3.6±0.7 vs. 3.3±0.5). Stress/rest perfusion imaging showed normal perfusion in 4 patients, fixed perfusion defects in 2 patients, and reversible perfusion defects in 2 patients, corresponding with angiographic results. Pooled results from the independent readers gave a sensitivity of 0.92 (CI 0.65-0.99) and specificity of 0.92 (CI 0.65-0.99) for the detection of coronary artery disease using ungated perfusion imaging. The same sensitivity, and a specificity of 1 (CI 0.76-1), was achieved when the images were self-gated after acquisition into near systole or near diastole. CONCLUSIONS Ungated radial dynamic perfusion CMR can give high quality imaging in patients in sinus rhythm and during atrial fibrillation. In this small cohort, high diagnostic accuracy was possible with this rapid perfusion imaging sequence. An ungated approach simplifies the acquisition and could expand the role of perfusion CMR to include patients with arrhythmia and those with gating problems.
Collapse
Affiliation(s)
- Alexis Harrison
- Division of Cardiology, University of Utah, Salt Lake City, UT, USA
- CARMA, Department of Internal Medicine, Salt Lake City, UT, USA
| | - Ganesh Adluru
- CARMA, Department of Internal Medicine, Salt Lake City, UT, USA
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, UT, USA
| | - Kavitha Damal
- CARMA, Department of Internal Medicine, Salt Lake City, UT, USA
| | - Akram M Shaaban
- Department of Radiology, University of Utah, Salt Lake City, UT, USA
| | - Brent Wilson
- Division of Cardiology, University of Utah, Salt Lake City, UT, USA
- CARMA, Department of Internal Medicine, Salt Lake City, UT, USA
| | - Daniel Kim
- CARMA, Department of Internal Medicine, Salt Lake City, UT, USA
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, UT, USA
- Department of Radiology, University of Utah, Salt Lake City, UT, USA
| | - Chris McGann
- Division of Cardiology, University of Utah, Salt Lake City, UT, USA
- CARMA, Department of Internal Medicine, Salt Lake City, UT, USA
| | - Nassir F Marrouche
- Division of Cardiology, University of Utah, Salt Lake City, UT, USA
- CARMA, Department of Internal Medicine, Salt Lake City, UT, USA
| | - Edward V R DiBella
- CARMA, Department of Internal Medicine, Salt Lake City, UT, USA
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, UT, USA
- Department of Bioengineering, University of Utah, Salt Lake City, UT, USA
- Department of Radiology, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
15
|
Kochiadakis GE, Kallergis EM. Impact of Atrial Fibrillation on Coronary Blood Flow: A Systematic Review. J Atr Fibrillation 2012; 5:458. [PMID: 28496766 DOI: 10.4022/jafib.458] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2011] [Revised: 08/01/2012] [Accepted: 09/04/2012] [Indexed: 11/10/2022]
Abstract
Patients with atrial fibrillation (AF) frequently present with symptoms suggestive of myocardial isch- aemia, even in the absence of significant CAD, that seem to be attributable to abnormalities of myocardial perfusion and perfusion reserve. According to the results of recent human and previous experimen- tal studies the increase in coronary artery blood flow during AF is smaller, while the coronary vascular resistance during the arrhythmia does not decrease as much as we would expect, suggesting a mismatch between coronary blood flow and myocardial metabolic demand. AF itself diminishes coronary flow reserve, especially in the subendocardial layer, partly as a result of the increase in the myocardial com- ponent of coronary vascular resistance, and it is possible that irregular ventricular rhythm may play an important role. The mismatch of coronary blood flow and myocardial metabolic demand, especially in view of the severe reduction in coronary flow reserve, may have deleterious consequences that are not limited to patients with CAD.
Collapse
|
16
|
|