Mircea AA, Donisan T, Feigenberg S, Fradley MG. What do national radiotherapy guidelines for patients with cardiac devices teach us? Heart Rhythm O2 2024; 5:189-193. [PMID: 38560371 PMCID: PMC10980919 DOI: 10.1016/j.hroo.2024.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2024] Open
Abstract
The incidence of cardiac implantable electronic device (CIED) malfunctions caused by radiotherapy (RT) is approximately 5%. Although individual national guidelines and expert consensus documents exist, the increased use of RT to treat various cancers points out the need for a standardized document to guide risk assessment and management of CIEDs during RT. We describe potential adverse RT-related events on CIEDs as well as the proposed mechanism of dysfunction. We review the main current guidelines and recommendations, emphasizing similarities and differences.
Collapse
Affiliation(s)
- Andrei Alexandru Mircea
- Electrophysiology and Heart Modeling Institute, Heart Rhythm Disease Institute, Bordeaux, France
| | - Teodora Donisan
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota
| | - Steven Feigenberg
- Radiation Oncology Department, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Michael G. Fradley
- Thalheimer Center for Cardio-Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
| |
Collapse
|
2
|
Defaye P, Biffi M, El-Chami M, Boveda S, Glikson M, Piccini J, Vitolo M. Cardiac pacing and lead devices management: 25 years of research at EP Europace journal. Europace 2023; 25:euad202. [PMID: 37421338 PMCID: PMC10450798 DOI: 10.1093/europace/euad202] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 07/03/2023] [Indexed: 07/10/2023] Open
Abstract
AIMS Cardiac pacing represents a key element in the field of electrophysiology and the treatment of conduction diseases. Since the first issue published in 1999, EP Europace has significantly contributed to the development and dissemination of the research in this area. METHODS In the last 25 years, there has been a continuous improvement of technologies and a great expansion of clinical indications making the field of cardiac pacing a fertile ground for research still today. Pacemaker technology has rapidly evolved, from the first external devices with limited longevity, passing through conventional transvenous pacemakers to leadless devices. Constant innovations in pacemaker size, longevity, pacing mode, algorithms, and remote monitoring highlight that the fascinating and exciting journey of cardiac pacing is not over yet. CONCLUSION The aim of the present review is to provide the current 'state of the art' on cardiac pacing highlighting the most important contributions from the Journal in the field.
Collapse
Affiliation(s)
- Pascal Defaye
- Cardiology Department, University Hospital and Grenoble Alpes University, CS 10217, Grenoble Cedex 9, Grenoble 38043, France
| | - Mauro Biffi
- Cardiology Unit, Cardiac Thoracic and Vascular Department, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Mikhael El-Chami
- Department of Medicine, Division of Cardiology, Emory University School of Medicine, Atlanta, Georgia, USA
| | - Serge Boveda
- Clinique Pasteur, Heart Rhythm Department, Toulouse, France
| | - Michael Glikson
- Cardiology Department, Jesselson Integrated Heart Center Shaare Zedek Medical Center and Hebrew University Faculty of Medicine, Jerusalem, Israel
| | - Jonathan Piccini
- Duke University, Duke Clinical Research Institute, Durham, NC, USA
| | - Marco Vitolo
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico Di Modena, Modena, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| |
Collapse
|
3
|
Malavasi VL, Imberti JF, Tosetti A, Romiti GF, Vitolo M, Zecchin M, Mazzeo E, Giuseppina DM, Lohr F, Lopez-Fernandez T, Boriani G. A systematic review and meta-analysis on oncological radiotherapy in patients with a cardiac implantable electronic device: Prevalence and predictors of device malfunction in 3121 patients. Eur J Clin Invest 2023; 53:e13862. [PMID: 36004486 PMCID: PMC10078179 DOI: 10.1111/eci.13862] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 08/19/2022] [Accepted: 08/23/2022] [Indexed: 12/15/2022]
Abstract
BACKGROUND The number of patients with cardiac implantable electronic devices (CIEDs) undergoing radiotherapy (RT) for cancer treatment is growing. At present, prevalence and predictors of RT-induced CIEDs malfunctions are not defined. METHODS Systematic review and meta-analysis conducted following the PRISMA recommendations. PubMed, Scopus and Google Scholar were searched from inception to 31/01/2022 for studies reporting RT-induced malfunctions in CIEDs patients. Aim was to assess the prevalence of RT-induced CIEDs malfunctions and identify potential predictors. RESULTS Thirty-two out of 3962 records matched the inclusion criteria and were included in the meta-analysis. A total of 135 CIEDs malfunctions were detected among 3121 patients (6.6%, 95% confidence interval [CI]: 5.1%-8.4%). The pooled prevalence increased moving from pacemaker (PM) to implantable cardioverter defibrillator (ICD), and cardiac resynchronization therapy and defibrillator (CRT-D) groups (4.1%, 95% CI: 2.9-5.8; 8.2% 95% CI: 5.9-11.3; and 19.8%, 95% CI: 11.4-32.2 respectively). A higher risk ratio (RR) of malfunctions was found when neutron-producing energies were used as compared to non-neutron-producing energies (RR 9.98, 95% CI: 5.09-19.60) and in patients with ICD/CRT-D as compared to patients with PM/CRT-P (RR 2.07, 95% CI: 1.40-3.06). On the contrary, no association was found between maximal radiation dose at CIED >2 Gy and CIEDs malfunctions (RR 0.93; 95% CI: 0.31-2.76). CONCLUSIONS Radiotherapy related CIEDs malfunction had a prevalence ranging from 4% to 20%. The use of neutron-producing energies and more complex devices (ICD/CRT-D) were associated with higher risk of device malfunction, while the radiation dose at CIED did not significantly impact on the risk unless higher doses (>10 Gy) were used.
Collapse
Affiliation(s)
- Vincenzo Livio Malavasi
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, Policlinico di Modena, University of Modena and Reggio Emilia, Modena, Italy
| | - Jacopo Francesco Imberti
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, Policlinico di Modena, University of Modena and Reggio Emilia, Modena, Italy.,Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy.,Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital, Liverpool, UK
| | - Alberto Tosetti
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, Policlinico di Modena, University of Modena and Reggio Emilia, Modena, Italy
| | - Giulio Francesco Romiti
- Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital, Liverpool, UK.,Department of Translational and Precision Medicine, Sapienza-University of Rome, Rome, Italy
| | - Marco Vitolo
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, Policlinico di Modena, University of Modena and Reggio Emilia, Modena, Italy.,Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy.,Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital, Liverpool, UK
| | - Massimo Zecchin
- Cardiovascular Department, Ospedali Riuniti, University of Trieste, Trieste, Italy
| | - Ercole Mazzeo
- Radiotherapy Division, Department of Oncology, Policlinico Di Modena, University of Modena and Reggio Emilia, Modena, Italy
| | - De Marco Giuseppina
- Radiotherapy Division, Department of Oncology, Policlinico Di Modena, University of Modena and Reggio Emilia, Modena, Italy
| | - Frank Lohr
- Radiotherapy Division, Department of Oncology, Policlinico Di Modena, University of Modena and Reggio Emilia, Modena, Italy
| | | | - Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, Policlinico di Modena, University of Modena and Reggio Emilia, Modena, Italy
| |
Collapse
|
4
|
Stühlinger M, Burri H, Vernooy K, Garcia R, Lenarczyk R, Sultan A, Brunner M, Sabbag A, Özcan EE, Ramos JT, Di Stolfo G, Suleiman M, Tinhofer F, Aristizabal JM, Cakulev I, Eidelman G, Yeo WT, Lau DH, Mulpuru SK, Nielsen JC, Heinzel F, Prabhu M, Rinaldi CA, Sacher F, Guillen R, de Pooter J, Gandjbakhch E, Sheldon S, Prenner G, Mason PK, Fichtner S, Nitta T. EHRA consensus on prevention and management of interference due to medical procedures in patients with cardiac implantable electronic devices. Europace 2022; 24:1512-1537. [PMID: 36228183 DOI: 10.1093/europace/euac040] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023] Open
Affiliation(s)
- Markus Stühlinger
- Department of Internal Medicine III - Cardiology and Angiology, Medical University of Innsbruck, Innsbruck, Austria
| | - Haran Burri
- Department of Cardiology, University Hospital of Geneva, Geneva, Switzerland
| | - Kevin Vernooy
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Rodrigue Garcia
- Department of Cardiology, University Hospital of Poitiers, Poitiers, France
- Department of Cardiology, Rigshospitalet, Copenhagen, Denmark
| | - Radoslaw Lenarczyk
- Department of Cardiology, Congenital Heart Disease and Electrotherapy, Medical University of Silesia, Silesian Center of Heart Diseases, Zabrze, Poland
- Medical University of Silesia, Division of Medical Sciences, Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Center for Heart Diseases, Zabrze, Poland
| | - Arian Sultan
- Department of Electrophysiology, Heart Center at University Hospital Cologne, Cologne, Germany
| | - Michael Brunner
- Department of Cardiology and Medical Intensive Care, St Josefskrankenhaus, Freiburg, Germany
| | - Avi Sabbag
- The Davidai Center for Rhythm Disturbances and Pacing, Chaim Sheba Medical Center, Ramat Gan, Israel
| | - Emin Evren Özcan
- Heart Rhythm Management Center, Dokuz Eylul University, İzmir, Turkey
| | - Jorge Toquero Ramos
- Cardiac Arrhythmia and Electrophysiology Unit, Cardiology Department, Puerta de Hierro University Hospital, Majadahonda, Madrid, Spain
| | - Giuseppe Di Stolfo
- Cardiac Intensive Care and Arrhythmology Unit, Fondazione IRCCS Casa Sollievo della Sofferenza, San Giovanni Rotondo, Italy
| | - Mahmoud Suleiman
- Cardiology/Electrophysiology, Rambam Health Care Campus, Haifa, Israel
| | | | | | - Ivan Cakulev
- University Hospitals of Cleveland, Case Western University, Cleveland, OH, USA
| | - Gabriel Eidelman
- San Isidro's Central Hospital, Diagnóstico Maipú, Buenos Aires Province, Argentina
| | - Wee Tiong Yeo
- Department of Cardiology, National University Heart Centre, Singapore, Singapore
| | - Dennis H Lau
- Centre for Heart Rhythm Disorders, The University of Adelaide and Royal Adelaide Hospital, Adelaide, SA, Australia
| | | | - Jens Cosedis Nielsen
- Department of Cardiology, Aarhus University Hospital, and Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Frank Heinzel
- Department of Cardiology, Charité University Medicine, Campus Virchow-Klinikum, 13353 Berlin, Germany
| | - Mukundaprabhu Prabhu
- Associate Professor in Cardiology, In charge of EP Division, Kasturba Medical College Manipal, Manipal, Karnataka, India
| | | | - Frederic Sacher
- Bordeaux University Hospital, Univ. Bordeaux, Bordeaux, France
| | - Raul Guillen
- Sanatorio Adventista del Plata, Del Plata Adventist University Entre Rios Argentina, Entre Rios, Argentina
| | - Jan de Pooter
- Professor of Cardiology, Ghent University, Deputy Head of Clinic, Heart Center UZ Gent, Ghent, Belgium
| | - Estelle Gandjbakhch
- AP-HP Sorbonne Université, Hôpital Pitié-Salpêtrière, Institut de Cardiologie, ICAN, Paris, France
| | - Seth Sheldon
- The Department of Cardiovascular Medicine, University of Kansas Health System, Kansas City, KS 66160, USA
| | | | - Pamela K Mason
- Director, Electrophysiology Laboratory, University of Virginia, Charlottesville, VA, USA
| | - Stephanie Fichtner
- LMU Klinikum, Medizinische Klinik und Poliklinik I, Campus Großhadern, München, Germany
| | - Takashi Nitta
- Emeritus Professor, Nippon Medical School, Presiding Consultant of Cardiology, Hanyu General Hospital, Saitama, Japan
| |
Collapse
|
5
|
Daniela Falco M, Andreoli S, Delana A, Barbareschi A, De Filippo P, Leidi C, Marini M, Appignani M, Genovesi D, Di Girolamo E. In-vitro investigation of cardiac implantable electronic device malfunction during and after direct photon exposure: A three-centres experience. Phys Med 2022; 94:94-101. [PMID: 35007940 DOI: 10.1016/j.ejmp.2021.12.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 11/26/2021] [Accepted: 12/28/2021] [Indexed: 10/19/2022] Open
Abstract
PURPOSE Radiotherapy may cause malfunction of implantable cardioverter-defibrillators (ICDs) and pacemakers (PMs). We carried-out a multicentre randomized in-vitro study on 65 ICDs and 145 PMs to evaluate malfunctions during and after direct irradiation to doses up to 10 Gy. METHODS Three centres equipped with different linear accelerator and treatment-planning systems participated in the study. Computed Tomography (CT) acquisitions were performed to build the treatment plans. All devices were exposed to dose of 2, 5, or 10 Gy (6 MV). All devices underwent a baseline examination and 64 wireless real-time telemetry-transmissions (47 ICDs and 17 PMs) were monitored during photon exposures. All devices were interrogated after exposure and once monthly for six subsequent months. RESULTS Fifty-four of the 64 wireless-enabled CIEDs (84.4%) recorded noise-related interferences during exposure. In detail, 40/47 ICDs (85.1%) reported interference, of which 16 ICDs (34%) reported potentially clinically relevant pacing inhibition and inappropriate detections. Following exposure, a soft reset occurred in 1/145 PM (0.7%) while 7/145 PMs (4.8%) reported battery issues. During the six-month follow-up, 1/145 PM (0.7%) reported a soft reset, while 12/145 more PMs (8.3%) and 1/64 ICD (1.5%) showed abnormal battery depletion. All reported issues occurred independently of exposure dose. Finally, irreversible effects on software and battery life occurred in only non-MRI-compatible devices. CONCLUSION ICDs mostly featured real-time transient sensing issues, while PMs mostly experienced long-term battery or software issues that were observed immediately following radiation exposure and during follow-up. Irreversible effects on battery life and software occurred in only non-MRI-compatible devices.
Collapse
Affiliation(s)
- Maria Daniela Falco
- Department of Radiation Oncology, "G. D'Annunzio" University, "SS. Annunziata" Hospital, Chieti, Italy.
| | - Stefano Andreoli
- Medical Physics Unit, ASST "Papa Giovanni XXIII", Bergamo, Italy
| | - Anna Delana
- Medical Physics Unit, "S. Chiara" Hospital, Trento, Italy
| | | | - Paolo De Filippo
- Electrophysiology Unit, ASST "Papa Giovanni XXIII", Bergamo, Italy
| | - Cristina Leidi
- Electrophysiology Unit, ASST "Papa Giovanni XXIII", Bergamo, Italy
| | | | | | - Domenico Genovesi
- Department of Radiation Oncology, "G. D'Annunzio" University, "SS. Annunziata" Hospital, Chieti, Italy
| | | |
Collapse
|
6
|
Konefał A, Bieniasiewicz M, Wendykier J, Adamczyk S, Wrońska A. Additional radiation sources in a treatment and control room of medical linear accelerators. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109513] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
7
|
Malavasi VL, De Marco G, Imberti JF, Placentino F, Vitolo M, Mazzeo E, Cicoria G, Casali E, Turco V, Lohr F, Boriani G. Radiotherapy-induced malfunctions of cardiac implantable electronic devices in cancer patients. Intern Emerg Med 2020; 15:967-973. [PMID: 31792775 DOI: 10.1007/s11739-019-02240-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Accepted: 11/19/2019] [Indexed: 11/30/2022]
Abstract
The number of patients with cardiac implantable electronic devices (CIEDs) requiring radiation therapy (RT) for cancer treatment is increasing. The purpose of this study is to estimate the prevalence, possible predictors, and clinical impact of RT-related CIEDs malfunctions. We retrospectively reviewed the medical records of all pacemaker (PM)/implantable cardioverter-defibrillator (ICD) patients who underwent RT in the last 14 years. One hundred and twenty-seven patients who underwent 150 separate RT courses were analysed (99 with a PM and 27 with an ICD). Of note, 21/127 (16.6%) patients were PM-dependent. Neutron-producing RT was used in 37/139 (26.6%) courses, whereas non-neutron-producing RT was used in 102/139 (73.4%) courses. The cumulative dose (Dmax) delivered to the CIED exceeded 5 Gy only in 2/132 (1.5%) cases. Device malfunctions were observed in 3/150 (2%) RT courses, but none was life-threatening or led to a major clinical event and all were resolved by CIED reprogramming. In all cases, the Dmax delivered to the CIED was < 2 Gy. Two malfunctions occurred in the 37 patients treated with neutron-producing RT (5.4%), and 1 malfunction occurred in the 102 patients treated with non-neutron-producing RT (1%) (p = 0.17). Device relocation from the RT field was performed in 2/127 (1.6%) patients. RT in patients with CIED is substantially safe if performed in an appropriately organized environment, with uncommon CIEDs malfunctions and no major clinical events. Neutron-producing energies, rather than Dmax, seem to increase the risk of malfunctions. Device interrogation on a regular basis is advised to promptly manage CIED malfunctions.
Collapse
Affiliation(s)
- Vincenzo L Malavasi
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico Di Modena, Via del Pozzo, 71, 41124, Modena, Italy
| | - Giuseppina De Marco
- Radiotherapy Division, Department of Oncology, University of Modena and Reggio Emilia, Policlinico Di Modena, Modena, Italy
| | - Jacopo F Imberti
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico Di Modena, Via del Pozzo, 71, 41124, Modena, Italy
| | - Filippo Placentino
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico Di Modena, Via del Pozzo, 71, 41124, Modena, Italy
| | - Marco Vitolo
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico Di Modena, Via del Pozzo, 71, 41124, Modena, Italy
| | - Ercole Mazzeo
- Radiotherapy Division, Department of Oncology, University of Modena and Reggio Emilia, Policlinico Di Modena, Modena, Italy
| | | | - Edoardo Casali
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico Di Modena, Via del Pozzo, 71, 41124, Modena, Italy
| | - Vincenzo Turco
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico Di Modena, Via del Pozzo, 71, 41124, Modena, Italy
| | - Frank Lohr
- Radiotherapy Division, Department of Oncology, University of Modena and Reggio Emilia, Policlinico Di Modena, Modena, Italy
| | - Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico Di Modena, Via del Pozzo, 71, 41124, Modena, Italy.
| |
Collapse
|
8
|
Radioactivity induced in new-generation cardiac implantable electronic devices during high-energy X-ray irradiation. Appl Radiat Isot 2020; 163:109206. [DOI: 10.1016/j.apradiso.2020.109206] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2020] [Revised: 03/27/2020] [Accepted: 04/24/2020] [Indexed: 01/17/2023]
|
9
|
Sharifzadehgan A, Laurans M, Thuillot M, Huertas A, Baudinaud P, Narayanan K, Mirabel M, Bibault JE, Frey P, Waldmann V, Varlet E, Amet D, Juin C, Lavergne T, Jouven X, Giraud P, Durdux C, Marijon E. Radiotherapy in Patients With a Cardiac Implantable Electronic Device. Am J Cardiol 2020; 128:196-201. [PMID: 32650920 DOI: 10.1016/j.amjcard.2020.04.045] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Revised: 04/20/2020] [Accepted: 04/27/2020] [Indexed: 10/24/2022]
Abstract
Recently, the Heart Rhythm Society published recommendations on management of patients with cardiac implantable electronic device (CIED) who require radiotherapy (RT). We aimed to report the experience of a teaching hospital, and discuss our practice in the context of recently published guidelines. We identified all consecutive CIED recipients (12,736 patients) who underwent RT between March 2006 and June 2017. Among them, 90 (1%) patients (78.2 ± 10 years, 73% male) had a CIED: 82 pacemakers and 8 implantable cardioverter-defibrillators. Two patients required CIED extraction prior to RT for ipsilateral breast cancer (no device replacement in 1 patient). Four patients (5%) were considered at high-risk, 35 (39%) at intermediate-risk, and the remaining 50 (56%) at low-risk for CIED dysfunction. Overall, only a minority of patients followed recommended local protocol during RT delivery (31%) and during follow-up (56%). CIED malfunction was detected in 5 patients (6%), mainly back-up mode resetting (80%), with 4 (including 3 pelvic cancer location) patients initially classified as being at intermediate-risk and 1 at low-risk. Four out of the 5 patients with CEID malfunction had received neutron producing beams. In conclusion, our findings underline the lack of rigorous monitoring of patients undergoing RT (though CIED malfunction appears to be rare and relatively benign in nature), and emphasize the interest of considering neutron producing beam for risk stratification as recommended in recent guidelines. Optimization of patient's management requires a close collaboration between both CIED clinicians and radiation oncologists, and more systematic remote CIED monitoring may be helpful.
Collapse
|
10
|
Mohamed MO, Barac A, Contractor T, Silvet H, Arroyo RC, Parwani P, Kwok CS, Martin GP, Patwala A, Mamas MA. Prevalence and in-hospital outcomes of patients with malignancies undergoing de novo cardiac electronic device implantation in the USA. Europace 2020; 22:1083-1096. [PMID: 32361739 DOI: 10.1093/europace/euaa087] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 03/27/2020] [Indexed: 11/12/2022] Open
Abstract
AIMS To study the outcomes of cancer patients undergoing cardiac implantable electronic device (CIED) implantation. METHODS AND RESULTS De novo CIED implantations (2004-15; n = 2 670 590) from the National Inpatient Sample were analysed for characteristics and in-hospital outcomes, stratified by presence of cancer (no cancer, historical and current cancers) and further by current cancer type (haematological, lung, breast, colon, and prostate). Current and historical cancer prevalence has increased from 3.3% to 7.8%, and 5.8% to 7.8%, respectively, between 2004 and 2015. Current cancer was associated with increased adjusted odds ratio (OR) of major adverse cardiovascular events (MACE) [composite of all-cause mortality, thoracic and cardiac complications, and device-related infection; OR 1.26, 95% confidence interval (CI) 1.23-1.30], all-cause mortality (OR 1.43, 95% CI 1.35-1.50), major bleeding (OR 1.38, 95% CI 1.32-1.44), and thoracic complications (OR 1.39, 95% CI 1.35-1.43). Differences in outcomes were observed according to cancer type, with significantly worse MACE, mortality and thoracic complications with lung and haematological malignancies, and increased major bleeding in colon and prostate malignancies. The risk of complications was also different according to CIED subtype. CONCLUSION The prevalence of cancer patients amongst those undergoing CIED implantation has significantly increased over 12 years. Overall, current cancers are associated with increased mortality and worse outcomes, especially in patients with lung, haematological, and colon malignancies whereas there was no evidence that historical cancer had a negative impact on outcomes.
Collapse
Affiliation(s)
- Mohamed O Mohamed
- Keele Cardiovascular Research Group, Centre for Prognosis Research, Institutes of Applied Clinical Science and Primary Care and Health Sciences, Keele University, Keele, UK.,Royal Stoke University Hospital, Stoke-on-Trent, UK
| | - Ana Barac
- Department of Cardio-Oncology, MedStar Heart and Vascular Institute, Washington, DC, USA
| | - Tahmeed Contractor
- Division of Cardiology, Department of Medicine, Loma Linda University Health, Loma Linda, CA, USA
| | - Helme Silvet
- Department of Cardiology, VA Loma Linda Healthcare System, Loma Linda, CA, USA
| | - Ruben Casado Arroyo
- Department of Cardiology, CUB Hopital Erasme, Université Libre de Bruxelles, Brussels, Belgium
| | - Purvi Parwani
- Division of Cardiology, Department of Medicine, Loma Linda University Health, Loma Linda, CA, USA
| | - Chun Shing Kwok
- Keele Cardiovascular Research Group, Centre for Prognosis Research, Institutes of Applied Clinical Science and Primary Care and Health Sciences, Keele University, Keele, UK.,Royal Stoke University Hospital, Stoke-on-Trent, UK
| | - Glen P Martin
- Division of Informatics, Imaging and Data Science, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Manchester, UK
| | | | - Mamas A Mamas
- Keele Cardiovascular Research Group, Centre for Prognosis Research, Institutes of Applied Clinical Science and Primary Care and Health Sciences, Keele University, Keele, UK.,Royal Stoke University Hospital, Stoke-on-Trent, UK.,Institute of Population Sciences, University of Manchester, Manchester, UK
| |
Collapse
|
11
|
Falco MD, Genovesi D, Caravatta L, Di Carlo C, Bliakharskaia E, Appignani M, Faustino M, Furia N, Di Girolamo E. A randomized in vitro evaluation of transient and permanent cardiac implantable electronic device malfunctions following direct exposure up to 10 Gy. Strahlenther Onkol 2020; 197:198-208. [PMID: 32561941 DOI: 10.1007/s00066-020-01651-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Accepted: 06/01/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND AND PURPOSE High-dose 6‑MV radiotherapy may cause cardiac implantable electronic devices (CIEDs) to malfunction. To assess CIED malfunctions resulting from direct exposure up to 10 Gy, 100 pacemakers (PMs) and 40 implantable cardioverter-defibrillators (ICDs) were evaluated. MATERIALS AND METHODS CIEDs underwent baseline interrogation. In ICDs, antitachycardia therapies were disabled via the programmer while the detection windows were left enabled. A computed tomography (CT) scan was performed to build the corresponding treatment plan. CIEDs were "blinded" and randomized to receive single doses of either 2, 5, or, 10 Gy via a 6-MV linear accelerator (linac) in a water phantom. Twenty-two wireless telemetry-enabled CIEDs underwent a real-time session, and their function was recorded by the video camera in the bunker. The CIEDs were interrogated after exposure and once monthly for 6 months. RESULTS During exposure, regardless of dose, 90.9% of the CIEDs recorded electromagnetic interference, with 6 ICDs (27.3%) reporting pacing inhibition and inappropriate arrhythmia detections. After exposure, a backup reset was observed in 1 PM (0.7% overall, 1% among PMs), while 7 PMs (5% overall, 7% among PMs) reported battery issues (overall immediate malfunction rate was 5.7%). During follow-up, 4 PMs (2.9% overall; 4% among PMs) and 1 ICD (0.7% overall; 2.5% among ICDs) reported abnormal battery depletion, and 1 PM (0.7% overall; 1% among PMs) reported a backup reset (overall late malfunction rate was 4.3%). CONCLUSION Apart from transient electromagnetic interference, last-generation CIEDs withstood direct 6‑MV exposure up to 10 Gy. Permanent battery or software errors occurred immediately or later only in less recent CIEDs.
Collapse
Affiliation(s)
- Maria Daniela Falco
- Department of Radiation Oncology, "SS. Annunziata" Hospital, "G. D'Annunzio" University, Via De' Vestini, 66100, Chieti, Italy.
| | - Domenico Genovesi
- Department of Radiation Oncology, "SS. Annunziata" Hospital, "G. D'Annunzio" University, Via De' Vestini, 66100, Chieti, Italy
| | - Luciana Caravatta
- Department of Radiation Oncology, "SS. Annunziata" Hospital, "G. D'Annunzio" University, Via De' Vestini, 66100, Chieti, Italy
| | - Clelia Di Carlo
- Department of Radiation Oncology, "SS. Annunziata" Hospital, "G. D'Annunzio" University, Via De' Vestini, 66100, Chieti, Italy
| | - Ekaterina Bliakharskaia
- Department of Clinical Medicine, Public Health, Life and Environmental Sciences, University of L'Aquila, L'Aquila, Italy
| | | | | | - Nanda Furia
- Arrhythmology Unit, "SS. Annunziata" Hospital, Chieti, Italy
| | | |
Collapse
|
12
|
Alitto AR, Chiesa S, Franco P, Fiore M, Marino L, Borghetti P, Desideri I, Greto D, Fiorentino A. PAIDEIA: pacemaker and implanted cardioverter defibrillator management in radiation therapy-a survey by the Young Group of the Italian Association of Radiotherapy and Clinical Oncology (AIRO). LA RADIOLOGIA MEDICA 2019; 125:329-335. [PMID: 31832987 DOI: 10.1007/s11547-019-01099-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Accepted: 10/16/2019] [Indexed: 11/25/2022]
Abstract
INTRODUCTION The management of patients bearing a cardiac implantable electronic device and needing a radiotherapy treatment is an important clinical scenario. The aim of this survey was to evaluate the level of awareness within the Italian Radiation Oncologist community on this topic. MATERIALS AND METHODS A survey was promoted by the Young Group of Italian Association of Radiotherapy and Clinical Oncology (AIRO) with a questionnaire made up of 22 questions allowing for multiple answers, which was administered, both online and on paper version. It was addressed to Radiation Oncologists, AIRO members, participating in the National Congress held in 2015. RESULTS A total of 113 questionnaires were collected back and analyzed (survey online: 50 respondents; paper version: 63). The answers showed a good level of awareness on the issue, but with a nonhomogeneous adherence to the different published guidelines (GL). There is a general low rate of referral for a preliminary cardiological evaluation in patients bearing PM/ICDs, in line with some published surveys; nevertheless, a focused attention to certain specific treatment factors and patient-centered point of view emerged. CONCLUSIONS A generally good awareness of this topic was shown but homogeneous application of GL was not observed, possibly due to the multiplicity of available GL. A prospective data collection could help to better clarify the shadows on this topics.
Collapse
Affiliation(s)
- Anna Rita Alitto
- UOC di Radioterapia Oncologica, Dipartimento Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Silvia Chiesa
- UOC di Radioterapia Oncologica, Dipartimento Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
| | - Pierfrancesco Franco
- Dipartimento di Oncologia - Radioterapia Oncologica, Università di Torino - AOU Citta' della Salute e della Scienza, Turin, Italy
| | - Michele Fiore
- Radioterapia Oncologica, Policlinico Universitario Campus Biomedico, Rome, Italy
| | | | - Paolo Borghetti
- Dipartimento di Radioterapia Oncologica, Università e ASST Spedali Civili di Brescia, Brescia, Italy
| | - Isacco Desideri
- Dipartimento di Scienze Biomediche Sperimentali e Cliniche Mario Serio, Radioterapia Oncologica, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Daniela Greto
- Dipartimento di Scienze Biomediche Sperimentali e Cliniche Mario Serio, Radioterapia Oncologica, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Alba Fiorentino
- Dipartimento di Radioterapia Oncologica, Ospedale Generale Regionale "F. Miulli", Acquaviva Delle Fonti, Bari, Italy
| |
Collapse
|
13
|
Bhat S, Gahungu N, Thavendiranathan P, Dwivedi G. The Role of Echocardiography in Cardio-oncology Patients: Contemporary Indications and Future Directions. CURRENT CARDIOVASCULAR IMAGING REPORTS 2019. [DOI: 10.1007/s12410-019-9519-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
14
|
Malavasi VL, Fantecchi E, Gianolio L, Pesce F, Longo G, Marietta M, Cascinu S, Lip GYH, Boriani G. Atrial fibrillation in patients with active malignancy and use of anticoagulants: Under-prescription but no adverse impact on all-cause mortality. Eur J Intern Med 2019; 59:27-33. [PMID: 30385084 DOI: 10.1016/j.ejim.2018.10.012] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2018] [Revised: 08/13/2018] [Accepted: 10/16/2018] [Indexed: 02/07/2023]
Abstract
Prescription of anticoagulants (ACs) in patients with cancer and atrial fibrillation (AF) is challenging and the impact on survival is not defined. In this study data prospectively collected in Oncology Units were retrospectively evaluated. Among 4664 patients admitted for malignancy, 394 patients (8.4%) had documented AF (mean age of 74 ± 9) and AC was prescribed to 155 patients (40%). Neither the type of cancer, the stage of the disease (metastatic or not) nor the ongoing treatments were significantly associated with prescription of AC, which was independently associated with BMI (OR 1.10; CI 95% 1.03-1.17; p = .003), valvular heart disease (OR 3.76; CI95% 1.59-8.87; p = .002), and previous venous thromboembolism (OR 6.67; 95%CI 2.67-16.70; p < .001). During a median follow-up of 212 days, survival from all-cause death was 37%, 28% and 18% at 6 months, 1 and 2 years, respectively. Only variables related to neoplastic disease or to patient clinical complexity were independently associated with mortality. A CHA2DS2VASc ≥ 4 was significantly associated with mortality (HR 1.33; 95%CI 1.06-1.67; p = .013). Treatment with ACs was not significantly related to mortality, neither in the whole cohort of patients, nor in patients with metastatic malignancies. In conclusion the prescription of ACs in patients with AF and active cancer was suboptimal, with one fourth of the patients not treated with ACs and one third using LMWH at prophylactic, non-therapeutic doses. Only few variables (BMI, valvular heart disease and previous venous thromboembolism) predicted prescription of ACs. Prescription of ACs was not associated with all-cause mortality, even in the subgroup with metastasis.
Collapse
Affiliation(s)
- Vincenzo Livio Malavasi
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Elisa Fantecchi
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Laura Gianolio
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Francesca Pesce
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Giuseppe Longo
- Oncology Division, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Marco Marietta
- Hematology Division, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Stefano Cascinu
- Oncology Division, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Gregory Y H Lip
- Institute of Cardiovascular Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy.
| |
Collapse
|
15
|
Boriani G, Fauchier L, Aguinaga L, Beattie JM, Blomstrom Lundqvist C, Cohen A, Dan GA, Genovesi S, Israel C, Joung B, Kalarus Z, Lampert R, Malavasi VL, Mansourati J, Mont L, Potpara T, Thornton A, Lip GYH, Gorenek B, Marin F, Dagres N, Ozcan EE, Lenarczyk R, Crijns HJ, Guo Y, Proietti M, Sticherling C, Huang D, Daubert JP, Pokorney SD, Cabrera Ortega M, Chin A. European Heart Rhythm Association (EHRA) consensus document on management of arrhythmias and cardiac electronic devices in the critically ill and post-surgery patient, endorsed by Heart Rhythm Society (HRS), Asia Pacific Heart Rhythm Society (APHRS), Cardiac Arrhythmia Society of Southern Africa (CASSA), and Latin American Heart Rhythm Society (LAHRS). Europace 2018; 21:7-8. [DOI: 10.1093/europace/euy110] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Accepted: 04/26/2018] [Indexed: 02/05/2023] Open
Affiliation(s)
- Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Laurent Fauchier
- Centre Hospitalier Universitaire Trousseau et Université François Rabelais, Tours, France
| | | | - James M Beattie
- Cicely Saunders Institute, King’s College London, London, UK
| | | | | | - Gheorghe-Andrei Dan
- Cardiology Department, University of Medicine and Pharmacy “Carol Davila”, Colentina University Hospital, Bucharest, Romania
| | - Simonetta Genovesi
- Department of Medicine and Surgery, University of Milano-Bicocca, Milano and Nephrology Unit, San Gerardo Hospital, Monza, Italy
| | - Carsten Israel
- Evangelisches Krankenhaus Bielefeld GmbH, Bielefeld, Germany
| | - Boyoung Joung
- Cardiology Division, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Zbigniew Kalarus
- SMDZ in Zabrze, Medical University of Silesia, Katowice; Department of Cardiology, Silesian Center for Heart Diseases, Zabrze, Poland
| | | | - Vincenzo L Malavasi
- Cardiology Division, Department of Nephrologic, Cardiac, Vascular Diseases, Azienda ospedaliero-Universitaria di Modena, Modena, Italy
| | - Jacques Mansourati
- University Hospital of Brest and University of Western Brittany, Brest, France
| | - Lluis Mont
- Arrhythmia Section, Cardiovascular Clínical Institute, Hospital Clinic, Universitat Barcelona, Barcelona, Spain
| | - Tatjana Potpara
- School of Medicine, Belgrade University, Belgrade, Serbia
- Cardiology Clinic, Clinical Centre of Serbia, Belgrade, Serbia
| | | | - Gregory Y H Lip
- Institute of Cardiovascular Sciences, University of Birmingham, UK
- Aalborg Thrombosis Research Unit, Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | | | | | | | | | - Radosław Lenarczyk
- Department of Cardiology, Congenital Heart Disease and Electrotherapy, Silesian Center for Heart Diseases, Zabrze, Poland
| | - Harry J Crijns
- Cardiology Maastricht UMC+ and Cardiovascular Research Institute Maastricht, Netherlands
| | - Yutao Guo
- Chinese PLA General Hospital, Beijing, People’s Republic of China
| | - Marco Proietti
- Institute of Cardiovascular Sciences, University of Birmingham, UK
- Department of Internal Medicine and Medical Specialties, Sapienza-University of Rome, Rome, Italy
| | | | - Dejia Huang
- Cardiology Division, Department of Medicine, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | | | - Sean D Pokorney
- Electrophysiology Section, Division of Cardiology, Duke University, Durham, NC, USA
| | - Michel Cabrera Ortega
- Department of Arrhythmia and Cardiac Pacing, Cardiocentro Pediatrico William Soler, Boyeros, La Havana Cuba
| | - Ashley Chin
- Department of Medicine, Groote Schuur Hospital, University of Cape Town, South Africa
| | | |
Collapse
|