1
|
Al-Asmari AI, Alharbi H, Al-Zahrani AE, Zughaibi TA. Heroin-Related Fatalities in Jeddah, Saudi Arabia, between 2008 and 2018. TOXICS 2023; 11:248. [PMID: 36977013 PMCID: PMC10099738 DOI: 10.3390/toxics11030248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Revised: 02/20/2023] [Accepted: 02/27/2023] [Indexed: 06/18/2023]
Abstract
To date, epidemiological studies have not evaluated heroin-related deaths in the Middle East and North African regions, especially Saudi Arabia. All heroin-related postmortem cases reported at the Jeddah Poison Control Center (JPCC) over a 10-year period (21 January 2008 to 31 July 2018) were reviewed. In addition, liquid chromatography electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was utilized to determine the 6-monoacetylmorphine (6-MAM), 6-acetylcodeine (6-AC), morphine (MOR), and codeine contents in unhydrolyzed postmortem specimens. Ninety-seven heroin-related deaths were assessed in this study, and they represented 2% of the total postmortem cases at the JPCC (median age, 38; 98% male). In the blood, urine, vitreous humor, and bile samples, the median morphine concentrations were 280 ng/mL, 1400 ng/mL, 90 ng/mL, and 2200 ng/mL, respectively; 6-MAM was detected in 60%, 100%, 99%, and 59% of the samples, respectively; and 6-AC was detected in 24%, 68%, 50%, and 30% of the samples, respectively. The highest number of deaths (33% of total cases) was observed in the 21-30 age group. In addition, 61% of cases were classified as "rapid deaths," while 24% were classified as "delayed deaths." The majority (76%) of deaths were accidental; 7% were from suicide; 5% were from homicide; and 11% were undetermined. This is the first epidemiological study to investigate heroin-related fatalities in Saudi Arabia and the Middle East and North African region. The rate of heroin-related deaths in Jeddah remained stable but increased slightly at the end of the study period. Most patients were heroin-dependent abusers and from the middle-aged group. The availability of urine, vitreous humor, and bile specimens provided valuable information regarding the opioids that were administered and the survival time following heroin injection.
Collapse
Affiliation(s)
- Ahmed I. Al-Asmari
- Laboratory Department, Ministry of Health, King Abdul-Aziz Hospital, Jeddah 21442, Saudi Arabia
- King Fahd Medical Research Center, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Hassan Alharbi
- Poison Control and Forensic Chemistry Center, Ministry of Health, Jeddah 21176, Saudi Arabia
| | | | - Torki A. Zughaibi
- King Fahd Medical Research Center, King Abdulaziz University, Jeddah 21589, Saudi Arabia
- Department of Medical Laboratory Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| |
Collapse
|
2
|
Hansen SL, Nielsen MKK, Linnet K, Rasmussen BS. Suitability of cardiac blood, brain tissue, and muscle tissue as alternative matrices for toxicological evaluation in postmortem cases. Drug Test Anal 2023; 15:529-538. [PMID: 36611280 DOI: 10.1002/dta.3439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 01/04/2023] [Accepted: 01/05/2023] [Indexed: 01/09/2023]
Abstract
Drug concentrations in peripheral blood are often used to evaluate whether death was caused by drug intoxication. In some cases, peripheral blood is not available, and analytical results of alternative matrices should instead be used in the toxicological evaluation. However, reference concentrations of alternative matrices are few, which makes interpretation of results a challenge. In this study, concentrations of selected benzodiazepines, opioids, illicit drugs, and other commonly used drugs in postmortem femoral blood, cardiac blood, brain tissue, and muscle tissue are presented. Alternative matrix-to-femoral blood drug concentration ratios and correlations of blood and alternative matrix drug concentrations were calculated to examine which of the investigated alternative matrices were most suited to use for toxicological evaluation in cases where peripheral blood is not available. The results showed that concentrations in cardiac blood, brain tissue, and muscle tissue could be useful in the postmortem evaluation of most of the 19 selected analytes. In most cases, analytes were detected in all the alternative matrices. The median concentration ratios for the selected analytes in brain tissue, cardiac blood, and muscle tissue relative to femoral blood ranged from 0.57 to 3.42, 0.59 to 1.87, and 0.67 to 7.04, respectively. Overall, cardiac blood provided the concentrations most comparable with femoral blood concentrations, indicating that cardiac blood can be useful in cases where femoral blood is not available. However, the measured concentrations should be interpreted with caution.
Collapse
Affiliation(s)
- Stine Lund Hansen
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Marie Katrine Klose Nielsen
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Kristian Linnet
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Brian Schou Rasmussen
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
3
|
Noufal Y, Kringel D, Toennes SW, Dudziak R, Lötsch J. Pharmacological data science perspective on fatal incidents of morphine treatment. Pharmacol Ther 2023; 241:108312. [PMID: 36423714 DOI: 10.1016/j.pharmthera.2022.108312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 11/10/2022] [Accepted: 11/14/2022] [Indexed: 11/23/2022]
Abstract
Morphine prescribed for analgesia has caused drug-related deaths at an estimated incidence of 0.3% to 4%. Morphine has pharmacological properties that make it particularly difficult to assess the causality of morphine administration with a patient's death, such as its slow transfer between plasma and central nervous sites of action and the existence of the active metabolite morphine-6-glucuronide with opioid agonistic effects, Furthermore, there is no well-defined toxic dose or plasma/blood concentration for morphine. Dosing is often adjusted for adequate pain relief. Here, we summarize reported deaths associated with morphine therapy, including associated morphine exposure and modulating patient factors such as pharmacogenetics, concomitant medications, or comorbidities. In addition, we systematically analyzed published numerical information on the stability of concentrations of morphine and its relevant metabolites in biological samples collected postmortem. A medicolegal case is presented in which the causality of morphine administration with death was in dispute and pharmacokinetic modeling was applied to infer the administered dose. The results of this analytical review suggest that (i) inference from postmortem blood concentrations to the morphine dose administered has low validity and (ii) causality between a patient's death and the morphine dose administered remains a highly context-dependent and collaborative assessment among experts from different medical specialties.
Collapse
Affiliation(s)
- Yazan Noufal
- Goethe-University, Institute of Clinical Pharmacology, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| | - Dario Kringel
- Goethe-University, Institute of Clinical Pharmacology, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| | - Stefan W Toennes
- Goethe-University, University Hospital Frankfurt, Institute of Legal Medicine, Kennedyallee 104, 60596 Frankfurt am Main, Germany
| | - Rafael Dudziak
- Goethe-University, University Hospital Frankfurt, Department of Anesthesiology, Intensive Care Medicine and Pain Therapy, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| | - Jörn Lötsch
- Goethe-University, Institute of Clinical Pharmacology, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany; Fraunhofer Institute for Translational Medicine and Pharmacology ITMP, Theodor-Stern-Kai 7, 60596 Frankfurt am Main, Germany.
| |
Collapse
|
4
|
Al-Asmari AI, Alharbi H, Zughaibi TA. Post-Mortem Analysis of Heroin Biomarkers, Morphine and Codeine in Stomach Wall Tissue in Heroin-Related Deaths. TOXICS 2022; 10:473. [PMID: 36006152 PMCID: PMC9413540 DOI: 10.3390/toxics10080473] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 08/07/2022] [Accepted: 08/11/2022] [Indexed: 06/15/2023]
Abstract
Toxicological analysis of some cases can be complicated by poor sample quality caused by decomposition. Although heroin-related deaths have been researched extensively, the interpretation of toxicology findings in these cases is challenging, especially in instances where blood samples are unavailable. Thus, it is important to develop analytical methods for different sample types. In this study. a method for the quantification of 6-monoacetylmorphine, 6-acetylcodeine, morphine, and codeine in postmortem stomach wall tissue using liquid chromatography coupled with tandem mass spectrometry was developed and validated. All calibration curves prepared with the stomach wall tissue were linear and ranged from 0.5−1000 ng/g with determination coefficients of >0.99 and a lower limit of quantification of 1.0 ng/g. The coefficients of variation for within-run precision and between-run precision were <9%. Matrix effects of stomach wall tissues and their extraction recoveries were investigated and ranged from −19% to +17% and 76% to 80%, respectively. Among the 16 analyzed heroin-related death cases, 6-monoacetylmorphine, 6-acetylcodeine, morphine, and codeine were detected in 75%, 31%, 100%, and 94% of all stomach wall tissues with median concentrations of 90 ng/g, 20 ng/g, 140 ng/g, and 30 ng/g, respectively. This study provides new data on the distribution of 6-monoacetylmorphine, 6-Acetylcodeine, morphine, and codeine in postmortem stomach wall tissue and suggests the usefulness of alternative matrices for investigating heroin-related fatalities when blood samples are unavailable. In addition, the prevalence of 6-monoacetylmorphine in the stomach wall tissue was higher than that in the liver and kidney tissues.
Collapse
Affiliation(s)
- Ahmed I. Al-Asmari
- Laboratory Department, Ministry of Health, King Abdul-Aziz Hospital, P.O. Box 6470, Jeddah 21442, Saudi Arabia
- King Fahd Medical Research Center, King Abdulaziz University, P.O. Box 80216, Jeddah 21589, Saudi Arabia
| | - Hassan Alharbi
- Poison Control and Forensic Chemistry Center, Ministry of Health, P.O. Box 21543, Jeddah 21176, Saudi Arabia
| | - Torki A. Zughaibi
- King Fahd Medical Research Center, King Abdulaziz University, P.O. Box 80216, Jeddah 21589, Saudi Arabia
- Department of Medical Laboratory Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, P.O. Box 80216, Jeddah 21589, Saudi Arabia
| |
Collapse
|
5
|
Lappas NT, Lappas CM. Morphine. Forensic Toxicol 2022. [DOI: 10.1016/b978-0-12-819286-3.00023-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
6
|
Lappas NT, Lappas CM. Heroin. Forensic Toxicol 2022. [DOI: 10.1016/b978-0-12-819286-3.00024-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
7
|
Distribution of tetrahydrocannabinol and cannabidiol in several different postmortem matrices. Forensic Sci Int 2021; 329:111082. [PMID: 34775328 DOI: 10.1016/j.forsciint.2021.111082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 10/15/2021] [Accepted: 10/22/2021] [Indexed: 11/21/2022]
Abstract
Cannabis is the most widely used illicit substance worldwide. A limited number of studies have investigated whether tetrahydrocannabinol (THC) and cannabidiol (CBD) can be detected in other postmortem matrices than blood and urine. The aim of this study was to investigate the distribution of THC and CBD in several different postmortem matrices. Concentrations in peripheral blood were compared to those in cardiac blood, pericardial fluid, psoas muscle, vastus lateralis muscle, and vitreous humor. A total of 39 postmortem forensic autopsy cases were included. THC and CBD were analyzed using gas chromatography-mass spectrometry. We were able to detect both THC and CBD in most of the analyzed matrices. For vitreous humor, however, only approximately 50% of the cases were available for analysis, and only two were found to be positive. Median concentrations in peripheral blood were 0.0040 (0.00042-0.056) mg/L for THC and 0.0013 (0-0.023) mg/L for CBD. The concentration ratios between pericardial fluid and cardiac blood compared to peripheral blood were< 1 for both THC and CBD for the majority of the cases. For THC, a median ratio of 0.60 (0.063-7.2) and 0.65 (0.068-4.8) were found for pericardial fluid and cardiac blood, respectively, compared to peripheral blood, whereas for CBD the corresponding median ratios were 0.40 (0.010-1.9) and 0.80 (0.017-2.4). The THC concentrations in psoas muscle and vastus lateralis muscle were high compared to those in peripheral blood in several cases, and large variations in the muscles to peripheral blood concentration ratios were seen. This was also the case for CBD. Our study shows that THC and CBD can be detected in postmortem matrices other than peripheral blood, and results from other matrices might provide important information in forensic cases where peripheral blood is not available. However, vitreous humor was not suitable for detecting neither THC nor CBD.
Collapse
|
8
|
Alternative matrices in forensic toxicology: a critical review. Forensic Toxicol 2021; 40:1-18. [DOI: 10.1007/s11419-021-00596-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 06/19/2021] [Indexed: 12/12/2022]
Abstract
Abstract
Purpose
The use of alternative matrices in toxicological analyses has been on the rise in clinical and forensic settings. Specimens alternative to blood and urine are useful in providing additional information regarding drug exposure and analytical benefits. The goal of this paper is to present a critical review on the most recent literature regarding the application of six common alternative matrices, i.e., oral fluid, hair, sweat, meconium, breast milk and vitreous humor in forensic toxicology.
Methods
The recent literature have been searched and reviewed for the characteristics, advantages and limitations of oral fluid, hair, sweat, meconium, breast milk and vitreous humor and its applications in the analysis of traditional drugs of abuse and novel psychoactive substances (NPS).
Results
This paper outlines the properties of six biological matrices that have been used in forensic analyses, as alternatives to whole blood and urine specimens. Each of this matrix has benefits in regards to sampling, extraction, detection window, typical drug levels and other aspects. However, theses matrices have also limitations such as limited incorporation of drugs (according to physical–chemical properties), impossibility to correlate the concentrations for effects, low levels of xenobiotics and ultimately the need for more sensitive analysis. For more traditional drugs of abuse (e.g., cocaine and amphetamines), there are already data available on the detection in alternative matrices. However, data on the determination of emerging drugs such as the NPS in alternative biological matrices are more limited.
Conclusions
Alternative biological fluids are important specimens in forensic toxicology. These matrices have been increasingly reported over the years, and this dynamic will probably continue in the future, especially considering their inherent advantages and the possibility to be used when blood or urine are unavailable. However, one should be aware that these matrices have limitations and particular properties, and the findings obtained from the analysis of these specimens may vary according to the type of matrix. As a potential perspective in forensic toxicology, the topic of alternative matrices will be continuously explored, especially emphasizing NPS.
Collapse
|
9
|
Hansen SL, Nielsen MKK, Linnet K, Rasmussen BS. Simple implementation of muscle tissue into routine workflow of blood analysis in forensic cases - A validated method for quantification of 29 drugs in postmortem blood and muscle samples by UHPLC-MS/MS. Forensic Sci Int 2021; 325:110901. [PMID: 34245938 DOI: 10.1016/j.forsciint.2021.110901] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 06/26/2021] [Accepted: 07/01/2021] [Indexed: 11/18/2022]
Abstract
Whole blood is most often the matrix of choice for postmortem analysis but it is not always available. In these cases, muscle tissue can be used as an alternative matrix. Therefore, an ultra-high-performance liquid chromatography-tandem mass spectrometry method for the quantification of 29 drugs and metabolites of toxicological interest in postmortem muscle tissue was developed and validated. Additionally, a validation of whole blood was carried out to compare the results from the two matrices. Solid-phase extraction was performed by an automated robotic system to minimize manual labour and risk of human errors, and increase robustness, sample throughput and sample traceability. The method was validated in terms of selectivity, matrix effect, extraction recovery, process efficiency, measuring range, lower limit of quantification, carry-over, stability, precision and accuracy. To correct for any inter-individual variability in matrix effects on analyte accuracy and precision, deuterated analogues of each analyte were used as internal standards. The lower limit of quantification in both blood and muscle homogenate ranged between 0.002 and 0.005 mg/kg, while the upper limit of quantification spanned from 0.20 to 1.0 mg/kg. Corrected with the 4-fold dilution factor, the corresponding concentrations in muscle tissue were 0.008-0.02 mg/kg at the lower limit of quantification and 0.80-4.0 mg/kg at the upper limit of quantification. The method showed acceptable precision and accuracy, with precision below 12% and accuracies ranging from 87% to 115% at up to 6 levels for all analytes in both matrices. In addition, comparison between calibration standards in spiked muscle homogenate and spiked blood showed that analyte concentrations in muscle samples could be quantified by using spiked blood samples as calibration standards with acceptable precision and accuracy when using deuterated analogues as internal standards. The investigation of matrix effects showed no great difference between blood and homogenates of non-decomposed and decomposed muscle tissue for most analytes. In the samples where high ion suppression or enhancement was observed, the results were corrected by the internal standards. Statistical comparison of quality control samples in blood and muscle tissue showed no obvious differences, and therefore muscle tissue was included in the routine method for analysis of blood samples and used in autopsy cases where no blood was available. By adding a semi-automated homogenization step before the remaining automated sample preparation, muscle tissue samples were easily incorporated into the workflow of the existing routine method. The present method has been successfully implemented in routine analysis of blood and muscle tissue since 2019.
Collapse
Affiliation(s)
- Stine Lund Hansen
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark.
| | - Marie Katrine Klose Nielsen
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Kristian Linnet
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Brian Schou Rasmussen
- Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| |
Collapse
|
10
|
Havig SM, Vindenes V, Øiestad ÅML, Rogde S, Thaulow CH. Methadone, Buprenorphine, Oxycodone, Fentanyl, and Tramadol in Multiple Postmortem Matrices. J Anal Toxicol 2021; 46:600-610. [PMID: 34115841 PMCID: PMC9282245 DOI: 10.1093/jat/bkab071] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 05/11/2021] [Accepted: 06/11/2021] [Indexed: 11/28/2022] Open
Abstract
Peripheral blood (PB) concentrations are generally preferred for postmortem toxicological interpretation, but some autopsy cases may lack blood for sampling due to decomposition or large traumas, etc. In such cases, other tissues or bodily fluids must be sampled; however, limited information exists on postmortem concentrations in matrices other than blood. Pericardial fluid (PF), muscle and vitreous humor (VH) have been suggested as alternatives to blood, but only a few studies have investigated the detection of opioids in these matrices. In this study, we aimed to investigate the detection of methadone, buprenorphine, oxycodone, fentanyl and tramadol in postmortem samples of PF, skeletal muscle and VH, in addition to PB and cardiac blood and if drug concentrations in these alternative matrices were comparable to those in PB and thereby useful for interpretation. In most of the 54 included cases, only one opioid was detected. Methadone, oxycodone, fentanyl and tramadol were detected in all of the alternative matrices in almost all cases, while buprenorphine was detected less often. For methadone, the concentrations in the alternative matrices, except in VH, were relatively similar to those in PB. Larger variations in concentrations were found for buprenorphine, oxycodone and tramadol. Quantitative analyses appeared useful for fentanyl, in all of the alternative matrices, but only four cases were included. Toxicological analyses of opioids in these alternative postmortem matrices can be useful for detection, but quantitative results must be interpreted with caution.
Collapse
Affiliation(s)
| | - Vigdis Vindenes
- Department of Forensic Sciences, Oslo University Hospital.,Institute of Clinical Medicine, Faculty of Medicine, University of Oslo
| | | | - Sidsel Rogde
- Department of Forensic Sciences, Oslo University Hospital
| | | |
Collapse
|
11
|
Al-Asmari AI. Postmortem Liver and Kidney Tissue Concentrations of Heroin Biomarkers and Their Metabolites in Heroin-Related Fatalities*†. J Forensic Sci 2020; 65:2087-2093. [PMID: 33460103 DOI: 10.1111/1556-4029.14537] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2020] [Revised: 07/15/2020] [Accepted: 07/16/2020] [Indexed: 01/23/2023]
Abstract
A method was developed and validated for analyzing 6-monoacetylmorphine, morphine, 6-acetylcodeine, and codeine in routine postmortem liver and kidney specimens using liquid chromatography-tandem mass spectrometry. Samples were prepared with a Stomacher instrument followed by solid-phase extraction. All calibration curves [0.5-1000 ng/g] were linear with coefficients of determination greater than 0.99 and limits of quantification of 1.0 ng/g. Within-run precision ranged between 2.0% and 8.0%, between-run precision ranged between 1.0% and 9.0%, and accuracy ranged between -5.0% and +3.0%. Matrix effects ranged from -18% to +9%. After matrix effects were excluded, analytical recoveries ranged from 76% to 94%. The distributions of 6-monoacetylmorphine, morphine, 6-acetylcodeine, and codeine were investigated in 31 postmortem cases in which heroin was the primary cause of death. In the current study, the median free morphine ratios were calculated for liver to blood and kidney to blood, which were 2.2 and 4.0, respectively. The current report highlights the importance of testing multiple specimens, including liver and kidney, in heroin-related deaths, especially if no blood samples are available. Furthermore, this work presents new information regarding the distribution of heroin metabolites in liver and kidney.
Collapse
Affiliation(s)
- Ahmed I Al-Asmari
- Laboratory Department, King Abdul-AzizHospital-Jeddah Health Affair, Ministry of Health, P.O. BOX 4670, Jeddah, Makkah AL-Mukharmah, 21442, Saudi Arabia
| |
Collapse
|
12
|
Wójtowicz A, Wietecha-Posłuszny R, Snamina M. Contemporary trends in drug analysis of vitreous humor: A critical review. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115935] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
13
|
Ferreira E, Corte Real F, Pinho e Melo T, Margalho C. A Novel Bioanalytical Method for the Determination of Opioids in Blood and Pericardial Fluid. J Anal Toxicol 2020; 44:754-768. [DOI: 10.1093/jat/bkaa064] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 05/23/2020] [Accepted: 06/03/2020] [Indexed: 12/28/2022] Open
Abstract
Abstract
Opioids are the drugs most commonly detected in overdose deaths and the second most consumed worldwide. An analytical methodology has been optimized and fully validated for the determination of codeine, morphine, 6-acetylmorphine, 6-acetylcodeine, oxycodone, oxymorphone and fentanyl in whole blood and pericardial fluid. The internal standards used were codeine-d3, morphine-d3, 6-acetylmorphine-d3 and fentanyl-d5. Before solid-phase extraction, volumes of 250 μL of blood and pericardial fluid were subjected to a protein precipitation (with 750 μL of ice-cold acetonitrile) and a microwave-induced oximation was performed using a solution of 1% aqueous hydroxylamine hydrochloride in phosphate-buffered saline (1:2, v/v). Finally, the dried extracts were further derivatized with a solution of n-methyl-n-(trimethylsilyl) trifluoroacetamide + 5% trimethylchlorosilane under microwave irradiation. The chromatographic analysis was carried out using gas chromatography–mass spectrometry operating in electron impact and selected ion monitoring mode. For all analytes, the method was linear between 5 and 1,000 ng/mL with determination coefficients (r2) >0.99. Depending on the analyte and matrix, the limit of detection varies between 3 and 4 ng/mL. Intra- and intermediate precision (<20%) and bias (±20%) were acceptable for all analytes in both matrices. The stability of the substances in the studied matrices was guaranteed, at least, 24 h in the autosampler, 4 h at room temperature and 30 days after three freeze/thaw cycles. This methodology was applied to real samples from the Laboratory of Chemistry and Forensic Toxicology, Centre Branch, of the National Institute of Legal Medicine and Forensic Sciences, Portugal.
Collapse
Affiliation(s)
- Elisa Ferreira
- Instituto Nacional de Medicina Legal e Ciências Forenses, I.P. (INMLCF, I.P.), Laboratório de Toxicologia Forense da Delegação do Centro, Azinhaga de Santa Comba - Polo das Ciências da Saúde, 3000-548 Coimbra, Portugal
- Departamento de Química da Faculdade de Ciências e Tecnologia da Universidade de Coimbra, R. Larga 2, 3004-535 Coimbra, Portugal
| | - Francisco Corte Real
- Instituto Nacional de Medicina Legal e Ciências Forenses, I.P. (INMLCF, I.P.), Laboratório de Toxicologia Forense da Delegação do Centro, Azinhaga de Santa Comba - Polo das Ciências da Saúde, 3000-548 Coimbra, Portugal
- Faculdade de Medicina da Universidade de Coimbra, Azinhaga de Santa Comba - Polo das Ciências da Saúde, 3000-548 Coimbra, Portugal
| | - Teresa Pinho e Melo
- Departamento de Química da Faculdade de Ciências e Tecnologia da Universidade de Coimbra, R. Larga 2, 3004-535 Coimbra, Portugal
| | - Cláudia Margalho
- Instituto Nacional de Medicina Legal e Ciências Forenses, I.P. (INMLCF, I.P.), Laboratório de Toxicologia Forense da Delegação do Centro, Azinhaga de Santa Comba - Polo das Ciências da Saúde, 3000-548 Coimbra, Portugal
| |
Collapse
|
14
|
Chan WS, Wong GF, Hung CW, Wong YN, Fung KM, Lee WK, Dao KL, Leung CW, Lo KM, Lee WM, Cheung BKK. Interpol review of toxicology 2016-2019. Forensic Sci Int Synerg 2020; 2:563-607. [PMID: 33385147 PMCID: PMC7770452 DOI: 10.1016/j.fsisyn.2020.01.018] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 01/23/2020] [Indexed: 12/13/2022]
Abstract
This review paper covers the forensic-relevant literature in toxicology from 2016 to 2019 as a part of the 19th Interpol International Forensic Science Managers Symposium. The review papers are also available at the Interpol website at: https://www.interpol.int/content/download/14458/file/Interpol%20Review%20.Papers%202019.pdf.
Collapse
|
15
|
Wang L, Ni C, Shen H, Sheng Z, Liang C, Wang R, Zhang Y. Comparison of the Detection Windows of Heroin Metabolites in Human Urine Using Online SPE and LC-MS/MS: Importance of Morphine-3-Glucuronide. J Anal Toxicol 2020; 44:22-28. [PMID: 31095707 DOI: 10.1093/jat/bkz040] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2018] [Revised: 02/21/2019] [Accepted: 04/24/2019] [Indexed: 11/12/2022] Open
Abstract
Heroin abuse is a serious problem that endangers human health and affects social stability. Though often being used as confirmation of heroin use, 6-monoacetylmorphine (6-MAM) has limitations due to its short detection window. To compare the detection windows of heroin metabolites (morphine (MOR), 6-MAM, morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G)) in human urine, an automated online solid phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and fully validated. The limits of detections (LODs) of the four metabolites were in the range of 1.25-5 ng/mL. Intra and inter-day precision for all the metabolites was 0.4-6.7% and 1.8-7.3%, respectively. Accuracy ranged from 92.9 to 101.7%. This method was then applied to the analysis of urine samples of 20 male heroin abusers. M3G was detected 9-11 days after admission to the drug rehabilitation institute in 40% of heroin users while MOR or M6G was not always detected. The detection window of M3G was thus the longest. Furthermore, M3G had a much higher concentration than MOR and M6G. Therefore, M3G could provide diagnostic information with regard to heroin exposure in the combination with other clues (e.g., heroin seizures at the scene).
Collapse
Affiliation(s)
- Luying Wang
- State Key Laboratory of New Drug and Pharmaceutical Process, China State Institute of Pharmaceutical Industry, Shanghai, China.,Shanghai Key Laboratory of Crime Scene Evidence, Shanghai Institute of Forensic Science, Shanghai, China
| | - Chunfang Ni
- Shanghai Key Laboratory of Crime Scene Evidence, Shanghai Institute of Forensic Science, Shanghai, China
| | | | - Zhenhai Sheng
- Shanghai Key Laboratory of Crime Scene Evidence, Shanghai Institute of Forensic Science, Shanghai, China
| | - Chen Liang
- Shanghai Key Laboratory of Crime Scene Evidence, Shanghai Institute of Forensic Science, Shanghai, China
| | - Rong Wang
- Shanghai Key Laboratory of Crime Scene Evidence, Shanghai Institute of Forensic Science, Shanghai, China
| | - Yurong Zhang
- Shanghai Key Laboratory of Crime Scene Evidence, Shanghai Institute of Forensic Science, Shanghai, China
| |
Collapse
|
16
|
Ma J, He Y, Zeng K, Liu X. Positive Urine Morphine Test in a Chinese Patient Receiving Methadone Maintenance Treatment After Eating Hot Pot: A Case Report. Front Psychiatry 2020; 11:637. [PMID: 32719626 PMCID: PMC7348055 DOI: 10.3389/fpsyt.2020.00637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 06/19/2020] [Indexed: 11/13/2022] Open
Abstract
Poppy shells contain opioids. It is a popular, but illegal spice in China. If these shells are added to food, urine morphine test of the patients involved in methadone maintenance treatment (MMT) can turn out positive. A 44-year-old male patient, who had been receiving MMT for 12 years with an extremely good treatment adherence, presented with positive urine morphine test in routine clinical compliance monitoring. However, the patient denied the use of any opioids recently. Coincidently, all of his four family members (none with a history of heroin abuse) showed positive results in urine morphine test. Considering that all these people ate a hot pot together a day before the test added to the speculation that the positive result could be due to the addition of poppy shell to the hot pot. Based on our results, we propose that this unusual phenomenon is worthy of clinical attention when managing patients at MMT clinics.
Collapse
Affiliation(s)
- Jun Ma
- Affiliated Wuhan Mental Health Center, Tongji Medical College, Huazhong University of Science & Technology, Wuhan, China
| | - Yafei He
- Affiliated Wuhan Mental Health Center, Tongji Medical College, Huazhong University of Science & Technology, Wuhan, China
| | - Kuan Zeng
- Affiliated Wuhan Mental Health Center, Tongji Medical College, Huazhong University of Science & Technology, Wuhan, China.,Research Center for Psychological and Health Sciences, China University of Geosciences, Wuhan, China
| | - Xuebing Liu
- Affiliated Wuhan Mental Health Center, Tongji Medical College, Huazhong University of Science & Technology, Wuhan, China.,Research Center for Psychological and Health Sciences, China University of Geosciences, Wuhan, China
| |
Collapse
|
17
|
Al‐Asmari AI. Postmortem Fluid Concentrations of Heroin Biomarkers and Their Metabolites. J Forensic Sci 2019; 65:570-579. [DOI: 10.1111/1556-4029.14200] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 09/06/2019] [Accepted: 09/06/2019] [Indexed: 11/28/2022]
|
18
|
Ketola RA, Kriikku P. Drug concentrations in post‐mortem specimens. Drug Test Anal 2019; 11:1338-1357. [DOI: 10.1002/dta.2662] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Revised: 06/10/2019] [Accepted: 06/11/2019] [Indexed: 01/20/2023]
Affiliation(s)
- Raimo A. Ketola
- Forensic Toxicology UnitNational Institute for Health and Welfare (THL) Mannerheimintie 166 FI‐00270 Helsinki Finland
| | - Pirkko Kriikku
- Forensic Toxicology UnitNational Institute for Health and Welfare (THL) Mannerheimintie 166 FI‐00270 Helsinki Finland
| |
Collapse
|
19
|
Maskell PD, Wilson NE, Seetohul LN, Crichton ML, Beer LJ, Drummond G, De Paoli G. Postmortem tissue distribution of morphine and its metabolites in a series of heroin-related deaths. Drug Test Anal 2018; 11:292-304. [DOI: 10.1002/dta.2492] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Revised: 08/20/2018] [Accepted: 08/20/2018] [Indexed: 02/02/2023]
Affiliation(s)
- Peter D. Maskell
- School of Science, Engineering and Technology; Abertay University; Dundee DD11HG UK
| | | | - L. Nitin Seetohul
- School of Science and Technology; Nottingham Trent University; Nottingham UK
| | | | | | | | | |
Collapse
|
20
|
Thaulow CH, Øiestad ÅML, Rogde S, Andersen JM, Høiseth G, Handal M, Mørland J, Vindenes V. Can measurements of heroin metabolites in post-mortem matrices other than peripheral blood indicate if death was rapid or delayed? Forensic Sci Int 2018; 290:121-128. [DOI: 10.1016/j.forsciint.2018.06.041] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Revised: 06/27/2018] [Accepted: 06/28/2018] [Indexed: 10/28/2022]
|