Tanabe Y, Kiritani M, Deguchi T, Hira N, Tomimoto S. Patient-specific respiratory motion management using lung tumors vs fiducial markers for real-time tumor-tracking stereotactic body radiotherapy. Phys Imaging Radiat Oncol 2022; 25:100405. [PMID: 36655212 PMCID: PMC9841282 DOI: 10.1016/j.phro.2022.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 11/17/2022] [Accepted: 12/21/2022] [Indexed: 12/25/2022] Open
Abstract
Background and purpose In real-time lung tumor-tracking stereotactic body radiotherapy (SBRT), tracking accuracy is related to radiotherapy efficacy. This study aimed to evaluate the respiratory movement relationship between a lung tumor and a fiducial marker position in each direction using four-dimensional (4D) computed tomography (CT) images. Materials and methods A series of 31 patients with a fiducial marker for lung SBRT was retrospectively analyzed using 4DCT. In the upper (UG) and middle and lower lobe groups (MLG), the cross-correlation coefficients of respiratory movement between the lung tumor and fiducial marker position in four directions (anterior-posterior, left-right, superior-inferior [SI], and three-dimensional [3D]) were calculated for each gating window (≤1, ≤2, and ≤ 3 mm). Subsequently, the proportions of phase numbers in unplanned irradiation (with lung tumors outside the gating window and fiducial markers inside the gating window) were calculated for each gating window. Results In the SI and 3D directions, the cross-correlation coefficients were significantly different between UG (mean r = 0.59, 0.63, respectively) and MLG (mean r = 0.95, 0.97, respectively). In both the groups, the proportions of phase numbers in unplanned irradiation were 11 %, 28 %, and 63 % for the ≤ 1-, ≤2-, and ≤ 3-mm gating windows, respectively. Conclusions Compared with MLG, fiducial markers for UG have low cross-correlation coefficients between the lung tumor and the fiducial marker position. Using 4DCT to assess the risk of unplanned irradiation in a gating window setting and selecting a high cross-correlation coefficient fiducial marker in advance are important for accurate treatment using lung SBRT.
Collapse
Affiliation(s)
- Yoshinori Tanabe
- Faculty of Medicine, Graduate School of Health Sciences, Okayama University, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan,Corresponding author.
| | - Michiru Kiritani
- Facilty of Health Sciences, Okayama University Medical School, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan
| | - Tomomi Deguchi
- Facilty of Health Sciences, Okayama University Medical School, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan
| | - Nanami Hira
- Facilty of Health Sciences, Okayama University Medical School, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan
| | - Syouta Tomimoto
- Facilty of Health Sciences, Okayama University Medical School, 2-5-1, Shikata, Kita, Okayama 700-8525, Japan
| |
Collapse
|
2
|
Ono T, Nakamura M, Ono Y, Nakamura K, Mizowaki T. Development of a plan complexity mitigation algorithm based on gamma passing rate predictions for volumetric-modulated arc therapy. Med Phys 2022; 49:1793-1802. [PMID: 35064567 DOI: 10.1002/mp.15466] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 12/28/2021] [Accepted: 12/29/2021] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND AND PURPOSE Volumetric-modulated arc therapy (VMAT) is a complex rotational therapy technique in which highly conformal dose distribution can be realized by varying the speed of gantry rotation, multileaf collimator (MLC) shape, and dose rate. However, the complexity of the technique creates a discrepancy between the calculated and measured doses. Thus, to mitigate the plan complexity in VMAT, this study aimed to develop an algorithm and evaluate its usefulness by conducting a feasibility study. MATERIALS AND METHODS A total of 50 patients who underwent VMAT between September 2015 and December 2020 were arbitrarily selected for this study. Specifically, patients with less than 85% gamma passing rate (GPR) at 5%/1 mm or 3%/2 mm criterion were selected randomly. Using the GPR prediction model, problematic MLC positions that contribute to a decrease in GPR were identified. Those problematic MLC positions were optimized using a limited nonlinear algorithm under mechanical limitations. Additionally, the dose prescription for the target was re-normalized. The VMAT modulated complexity score (MCSv ), averaged aperture area (AA), and monitor unit per gray (MU/Gy) were evaluated as plan complexity parameters. Calculated doses in patient geometry were evaluated for the target and its surrounding region. In addition, an ArcCHECK cylindrical diode array was used to measure the dose, and GPRs at 5%/1 mm and 3%/2 mm criteria were evaluated to analyze the difference between the mitigated and original plans. The difference was calculated using the mean ± standard deviation. RESULTS The differences between the MCSv , AA, and MU/cGy values for the mitigated and original plans were 0.8 ± 1.7 (× 10-2 ), 42.7 ± 57.9, and -5.6 ± 8.5, respectively. Regarding the calculated dose, the dose volume parameters were consistent within 1% for the target and the surrounding region. The differences between the mitigated and original plans were 1.8 ± 2.9% and 1.3 ± 1.8% for GPRs at 5%/1 mm and 3%/2 mm, respectively. CONCLUSIONS This feasibility study resulted in the development of an algorithm with the potential to mitigate plan complexity and improve the GPR for VMAT under minor leaf position modifications. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Tomohiro Ono
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Mitsuhiro Nakamura
- Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Yuka Ono
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Kiyonao Nakamura
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| |
Collapse
|
3
|
Treatment planning comparison between dynamic wave arc and volumetric modulated arc therapies for prostate-cancer treatment. Med Dosim 2021; 47:48-53. [PMID: 34538693 DOI: 10.1016/j.meddos.2021.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 07/05/2021] [Accepted: 08/08/2021] [Indexed: 11/21/2022]
Abstract
The aim of this study was to compare the quality of dynamic wave arc (DWA) and coplanar volumetric modulated arc therapy (co-VMAT) plans for the treatment of localized prostate cancer. The planning target volume (PTV)-rectum, a section of the PTV comprising the PTV minus that of the rectum, received 78 Gy in 39 fractions as the mean dose to the PTV-rectum. The DWA and co-VMAT plans were generated for each patient using the RayStation treatment planning system for the Vero4DRT system. The PTV-rectum dose (D95%: the percent dose irradiating 95% of the volume), homogeneity index (HI), conformity index (CI), as well as doses to the bladder wall, rectum wall (V10-70 Gy: the percent volume receiving 10-70 Gy), and bilateral femoral heads of the DWA and co-VMAT plans were compared. The output monitor unit (MU) and delivery time obtained for each set of plans were also investigated. In terms of target coverage, the DWA plans provided an average D95% of 75.5 Gy, which was comparable to the co-VMAT-plan D95% of 75.2 Gy (p < 0.05). The HI was significantly better with the DWA. As for the DWA plans, the bladder-wall volume receiving 10, 20, 30, and 40 Gy (V10-40 Gy) was significantly smaller than that of the co-VMAT plans, and the volume of the rectal wall receiving 10 Gy (V10Gy) was significantly larger than that of the co-VMAT plans. The DWA plans yielded a reduced dose to the bilateral femoral heads compared with the co-VMAT plans (p < 0.05). The values of the CI and MU, and the delivery time exhibited no significant differences between the DWA and co-VMAT plans. The DWA plan is a feasible treatment option for prostate cancer radiotherapy.
Collapse
|
4
|
Highly hypofractionated intensity-modulated radiation therapy for nonmetastatic prostate cancer with a simultaneous integrated boost to intraprostatic lesions: a planning study. Jpn J Radiol 2021; 40:210-218. [PMID: 34350542 DOI: 10.1007/s11604-021-01186-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 07/26/2021] [Indexed: 12/09/2022]
Abstract
PURPOSE The purpose of this planning study was to develop an acceptable technique for highly hypofractionated intensity-modulated radiation therapy using simultaneous integrated boost technique (SIB-hHF-RT) for nonmetastatic National Comprehensive Cancer Network high-risk prostate cancer. MATERIALS AND METHODS We created SIB-hHF-RT plans for 14 nonmetastatic prostate cancer patients with MRI-detectable intraprostatic lesions (IPLs) and without intestines locating close to the seminal vesicle and prostate. We prescribed 57 Gy for IPLs and 54 Gy for the remainder of planning target volume (PTV) in 15 fractions. The IPLs were contoured based on magnetic resonance imaging, and PTV was generated by adding 6-8-mm margins to the clinical target volume. For the dose-volume constraints of organs at risk (OARs), the same constraints as 54 Gy plans were used so as not to increase the toxicity. RESULTS All created plans fulfilled the dose-volume constraints of all targets and OARs. The median estimated beam-on time was 108.5 s. For patient-specific quality assurance, the global gamma passing rates (3%/2 mm) with 10% dose threshold criteria were greater than 93% in all cases and greater than 95% in 11 cases. CONCLUSION SIB-hHF-RT plans were developed that fulfill the acceptable dose-volume constraints and pass patient-specific quality assurance. We believe these plans can be applied to selected patients with nonmetastatic prostate cancer.
Collapse
|
5
|
Rostamzadeh M, Ishihara Y, Nakamura M, Popescu IA, Mestrovic A, Gete E, Fedrigo R, Bergman AM. Monte Carlo simulation of 6-MV dynamic wave VMAT deliveries by Vero4DRT linear accelerator using EGSnrc moving sources. J Appl Clin Med Phys 2020; 21:206-218. [PMID: 33219743 PMCID: PMC7769401 DOI: 10.1002/acm2.13090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Revised: 08/12/2020] [Accepted: 10/06/2020] [Indexed: 12/02/2022] Open
Abstract
The commissioning and benchmark of a Monte Carlo (MC) model of the 6‐MV Brainlab‐Mitsubishi Vero4DRT linear accelerator for the purpose of quality assurance of clinical dynamic wave arc (DWA) treatment plans is reported. Open‐source MC applications based on EGSnrc particle transport codes are used to simulate the medical linear accelerator head components. Complex radiotherapy irradiations can be simulated in a single MC run using a shared library format combined with BEAMnrc “source20.” Electron energy tuning is achieved by comparing measured vs simulated percentage depth doses (PDDs) for MLC‐defined field sizes in a water phantom. Electron spot size tuning is achieved by comparing measured and simulated inplane and crossplane beam profiles. DWA treatment plans generated from RayStation (RaySearch) treatment planning system (TPS) are simulated on voxelized (2.5 mm3) patient CT datasets. Planning target volume (PTV) and organs at risk (OAR) dose–volume histograms (DVHs) are compared to TPS‐calculated doses for clinically deliverable dynamic volumetric modulated arc therapy (VMAT) trajectories. MC simulations with an electron beam energy of 5.9 MeV and spot size FWHM of 1.9 mm had the closest agreement with measurement. DWA beam deliveries simulated on patient CT datasets results in DVH agreement with TPS‐calculated doses. PTV coverage agreed within 0.1% and OAR max doses (to 0.035 cc volume) agreed within 1 Gy. This MC model can be used as an independent dose calculation from the TPS and as a quality assurance tool for complex, dynamic radiotherapy treatment deliveries. Full patient CT treatment simulations are performed in a single Monte Carlo run in 23 min. Simulations are run in parallel using the Condor High‐Throughput Computing software1 on a cluster of eight servers. Each server has two physical processors (Intel Xeon CPU E5‐2650 0 @2.00 GHz), with 8 cores per CPU and two threads per core for 256 calculation nodes.
Collapse
Affiliation(s)
- Maryam Rostamzadeh
- Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, Canada
| | | | | | | | - Ante Mestrovic
- Medical Physics Department, BC Cancer-Vancouver, Vancouver, Canada
| | - Ermias Gete
- Medical Physics Department, BC Cancer-Vancouver, Vancouver, Canada
| | - Roberto Fedrigo
- Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, Canada
| | | |
Collapse
|
6
|
Hiraoka M, Mizowaki T, Matsuo Y, Nakamura M, Verellen D. The gimbaled-head radiotherapy system: Rise and downfall of a dedicated system for dynamic tumor tracking with real-time monitoring and dynamic WaveArc. Radiother Oncol 2020; 153:311-318. [PMID: 32659250 DOI: 10.1016/j.radonc.2020.07.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 07/01/2020] [Accepted: 07/02/2020] [Indexed: 10/23/2022]
Abstract
A gimbaled-head radiotherapy device was developed by industry-academic collaborations, with a concept of robust structures whilst maintaining high flexibilities, and its clinical application started in 2008. The unique structures with multi-image guidance functions initiated 2 new treatment modalities. One is dynamic tumor tracking radiotherapy with real time monitoring (DTTRM), which enables 4-D radiotherapy without prolongation of radiotherapy treatment time. This treatment has become clinically feasible for stereotactic body radiotherapy (SBRT) of lung cancers and liver tumors, and intensity-modulated radiotherapy (IMRT) for pancreatic cancers. The second one is Dynamic WaveArc therapy (DWA), the non-coplanar versatility of the SBRT system by combining the gantry-ring synchronized rotation with dynamic multileaf collimator optimization. DWA opens the possibility to create patient-individualized treatment plans, allowing additional flexibility in organ at risk sparing while preserving dosimetric robust delivery. The clinical usefulness of the DWA has been preliminary shown for those tumors in the prostate, breast and skull base. Prospective clinical trials are under way with a support of the national funding of Japan for DTTRM and DWA, respectively. Marketing of the system was terminated in 2016 due to a commercial decision. However, lessons can be learned from the development process of this device that might be useful for those who have interests in new technologies and clinical applications in radiation oncology. This review article aims to summarize the developments and achievements of a gimbaled-head radiotherapy device with a focus on DTTRM and DWA.
Collapse
Affiliation(s)
- Masahiro Hiraoka
- Department of Radiation Oncology, Japanese Red Cross Wakayama Medical Center, Japan.
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan
| | - Yukinori Matsuo
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan
| | - Mitsuhiro Nakamura
- Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, Japan
| | - Dirk Verellen
- Iridium Kankernetwerk, Antwerp University, Faculty of Medicine and Health Sciences, Belgium
| |
Collapse
|
7
|
Ono T, Hirashima H, Iramina H, Mukumoto N, Miyabe Y, Nakamura M, Mizowaki T. Prediction of dosimetric accuracy for VMAT plans using plan complexity parameters via machine learning. Med Phys 2019; 46:3823-3832. [PMID: 31222758 DOI: 10.1002/mp.13669] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2019] [Revised: 06/13/2019] [Accepted: 06/13/2019] [Indexed: 12/13/2022] Open
Abstract
PURPOSE The dosimetric accuracies of volumetric modulated arc therapy (VMAT) plans were predicted using plan complexity parameters via machine learning. METHODS The dataset consisted of 600 cases of clinical VMAT plans from a single institution. The predictor variables (n = 28) for each plan included complexity parameters, machine type, and photon beam energy. Dosimetric measurements were performed using a helical diode array (ArcCHECK), and the dosimetric accuracy of the passing rates for a 5% dose difference (DD5%) and gamma index of 3%/3 mm (γ3%/3 mm) were predicted using three machine learning models: regression tree analysis (RTA), multiple regression analysis (MRA), and neural networks (NNs). First, the prediction models were applied to 500 cases of the VMAT plans. Then, the dosimetric accuracy was predicted using each model for the remaining 100 cases (evaluation dataset). The error between the predicted and measured passing rates was evaluated. RESULTS For the 600 cases, the mean ± standard deviation of the measured passing rates was 92.3% ± 9.1% and 96.8% ± 3.1% for DD5% and γ3%/3 mm, respectively. For the evaluation dataset, the mean ± standard deviation of the prediction errors for DD5% and γ3%/3 mm was 0.5% ± 3.0% and 0.6% ± 2.4% for RTA, 0.0% ± 2.9% and 0.5% ± 2.4% for MRA, and -0.2% ± 2.7% and -0.2% ± 2.1% for NN, respectively. CONCLUSIONS NNs performed slightly better than RTA and MRA in terms of prediction error. These findings may contribute to increasing the efficiency of patient-specific quality-assurance procedures.
Collapse
Affiliation(s)
- Tomohiro Ono
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| | - Hideaki Hirashima
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| | - Hiraku Iramina
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan.,Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School Medicine, Kyoto University, Kyoto, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| |
Collapse
|
8
|
Uto M, Ogura K, Mukumoto N, Miyabe Y, Nakamura M, Hirashima H, Katagiri T, Takehana K, Hiraoka M, Mizowaki T. Single-isocenter volumetric-modulated Dynamic WaveArc therapy for two brain metastases. Jpn J Radiol 2019; 37:619-625. [PMID: 31230185 DOI: 10.1007/s11604-019-00849-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Accepted: 06/16/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE A new irradiation technique, volumetric-modulated Dynamic WaveArc therapy (VMDWAT), based on sequential non-coplanar trajectories, can be performed using the Vero4DRT. This planning study compared the dose distribution and treatment time between single-isocenter volumetric-modulated arc therapy (VMAT) with multiple straight non-coplanar arcs and single-isocenter VMDWAT in patients with two brain metastases. MATERIALS AND METHODS Twenty patients with two planning target volumes exceeding 2.0 cm3 were included. Both VMAT and VMDWAT plans were created with single isocenter and a prescribed dose of 28 Gy delivered in five fractions. Target conformity was evaluated using indices modified from the RTOG-CI (mRTOG-CI) and IP-CI (mIP-CI). RESULTS VMDWAT significantly improved both mRTOG-CI and mIP-CI and reduced the volume of normal brain tissue receiving 25 and 28 Gy compared to VMAT. The two modalities did not significantly differ in terms of the volume of normal brain tissue receiving 5, 10, 12, 15, and 20 Gy. The mean treatment time was significantly shorter in the VMDWAT group. CONCLUSION VMDWAT significantly improved dose distribution in a shorter treatment time compared to VMAT in patients treated for two brain metastases. Single-isocenter VMDWAT may thus be a promising treatment for two brain metastases.
Collapse
Affiliation(s)
- Megumi Uto
- Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Kengo Ogura
- Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.,Department of Therapeutic Radiology, Kobe City Medical Center General Hospital, 2-2-1, Minatojimaminamimachi, Chuo-ku, Kobe, Hyogo, Japan
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.,Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University Graduate School of Medicine, 53, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, Japan
| | - Hideaki Hirashima
- Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Tomohiro Katagiri
- Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.,Department of Radiation Oncology, Shizuoka City Shizuoka Hospital, 10-93, Otemachi, Aoi-ku, Shizuoka, Shizuoka, Japan
| | - Keiichi Takehana
- Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.,Japanese Red Cross Wakayama Medical Center, 4-20, Komatsubara-dori, Wakayama, Wakayama, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.
| |
Collapse
|
9
|
Smyth G, Evans PM, Bamber JC, Bedford JL. Recent developments in non-coplanar radiotherapy. Br J Radiol 2019; 92:20180908. [PMID: 30694086 PMCID: PMC6580906 DOI: 10.1259/bjr.20180908] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Revised: 01/15/2019] [Accepted: 01/17/2019] [Indexed: 11/05/2022] Open
Abstract
This paper gives an overview of recent developments in non-coplanar intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Modern linear accelerators are capable of automating motion around multiple axes, allowing efficient delivery of highly non-coplanar radiotherapy techniques. Novel techniques developed for C-arm and non-standard linac geometries, methods of optimization, and clinical applications are reviewed. The additional degrees of freedom are shown to increase the therapeutic ratio, either through dose escalation to the target or dose reduction to functionally important organs at risk, by multiple research groups. Although significant work is still needed to translate these new non-coplanar radiotherapy techniques into the clinic, clinical implementation should be prioritized. Recent developments in non-coplanar radiotherapy demonstrate that it continues to have a place in modern cancer treatment.
Collapse
Affiliation(s)
- Gregory Smyth
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, UK
| | | | - Jeffrey C Bamber
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, UK
| | - James L Bedford
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, UK
| |
Collapse
|
10
|
Comi S, Bazani A, Emiro F, Piperno G, Baldini F, Jereczek-Fossa B, Cattani F. 173. Dosimetrical evaluation of interplay effect for lung cancer treatments with Vero system: Comparison between three different techniques. Phys Med 2018. [DOI: 10.1016/j.ejmp.2018.04.184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
11
|
Nakayama S, Monzen H, Onishi Y, Kaneshige S, Kanno I. Estimation of extremely small field radiation dose for brain stereotactic radiotherapy using the Vero4DRT system. Phys Med 2018; 50:52-58. [DOI: 10.1016/j.ejmp.2018.05.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Revised: 05/23/2018] [Accepted: 05/24/2018] [Indexed: 10/14/2022] Open
|
12
|
Ono Y, Yoshimura M, Hirata K, Ono T, Hirashima H, Mukumoto N, Nakamura M, Inoue M, Hiraoka M, Mizowaki T. Dosimetric advantages afforded by a new irradiation technique, Dynamic WaveArc, used for accelerated partial breast irradiation. Phys Med 2018; 48:103-110. [PMID: 29728221 DOI: 10.1016/j.ejmp.2018.03.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Revised: 03/13/2018] [Accepted: 03/23/2018] [Indexed: 12/25/2022] Open
Abstract
PURPOSE To identify dosimetric advantages of the novel Dynamic WaveArc (DWA) technique for accelerated partial breast irradiation (APBI), compared with non-coplanar three-dimensional conformal radiotherapy (nc3D-CRT) and coplanar tangential volumetric modulated arc therapy (tVMAT) with dual arcs of 45-65°. METHODS Vero4DRT enables DWA by continuous gantry rotation and O-ring skewing with movement of the multi-leaf collimator. We compared the dose distributions of DWA, nc3D-CRT and tVMAT in 24 consecutive left-sided breast cancer patients treated with APBI (38.5 Gy in 10 fractions). The average doses and volumes to the planning target volume (PTV) and organs at risk, especially heart and left anterior descending artery (LAD) were compared among DWA, nc3D-CRT and tVMAT. RESULTS The doses and volumes to the PTVs did not differ significantly among the three plans. For the DWA plans, the mean dose to the heart was 0.2 ± 0.1 Gy, less than those of the nc3D-CRT and tVMAT plans. The D2% values of the planning organ at risk volume of the LAD were 9.3 ± 10.9%, 28.2 ± 31.9% and 20.3 ± 25.7% for DWA, nc3D-CRT and tVMAT, respectively. The V20Gy and V10Gy of the ipsilateral lung for the DWA plans were also significantly lower. CONCLUSIONS DWA allowed to find a better compromise for OAR which overlapped with the PTV. Use of the DWA for APBI improved the dose distributions compared with those of nc3D-CRT and tVMAT.
Collapse
Affiliation(s)
- Yuka Ono
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Michio Yoshimura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Kimiko Hirata
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Tomohiro Ono
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Hideaki Hirashima
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan; Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Minoru Inoue
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| |
Collapse
|
13
|
Hirashima H, Nakamura M, Miyabe Y, Uto M, Nakamura K, Mizowaki T. Monitoring of mechanical errors and their dosimetric impact throughout the course of non-coplanar continuous volumetric-modulated arc therapy. Radiat Oncol 2018; 13:27. [PMID: 29444693 PMCID: PMC5813375 DOI: 10.1186/s13014-018-0972-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Accepted: 02/11/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Volumetric-modulated Dynamic WaveArc therapy (VMDWAT) is a non-coplanar continuous volumetric modulated radiation therapy (VMAT) delivery technique. Here, we monitored mechanical errors and their impact on dose distributions in VMDWAT using logfiles throughout the course of treatment. METHODS Fifteen patients were enrolled (2 skull base tumor patients and 13 prostate cancer patients). VMDWAT plans were created for the enrolled patients. The prescribed dose for the skull base tumor was set as 54 Gy at 1.8 Gy per fraction, and that for the prostate cancer was set as 72 to 78 Gy at 2 Gy per fraction. We acquired logfiles to monitor mechanical errors and their impact on dose distribution in each fraction. The root mean square error (RMSE) in the multi-leaf collimator (MLC), gantry angle, O-ring angle and monitor unit (MU) were calculated using logfiles throughout the course of VMDWAT for each patient. The dosimetric impact of mechanical errors throughout the course of VMDWAT was verified using a logfile-based dose reconstruction method. Dosimetric errors between the reconstructed plans and the original plans were assessed. RESULTS A total of 517 datasets, including 55 datasets for the 2 skull base tumor patients and 462 datasets for the 13 prostate cancer patients, were acquired. The RMSE values were less than 0.1 mm, 0.2°, 0.1°, and 0.4 MU for MLC position, gantry angle, O-ring angle, and MU, respectively. For the skull base tumors, the absolute mean dosimetric errors and two standard deviations throughout the course of treatment were less than 1.4% and 1.1%, respectively. For prostate cancer, these absolute values were less than 0.3% and 0.5%, respectively. The largest dosimetric error of 2.5% was observed in a skull base tumor patient. The resultant dosimetric error in the accumulated daily delivered dose distribution, in the patient with the largest error, was up to 1.6% for all dose-volumetric parameters relative to the planned dose distribution. CONCLUSIONS MLC position, gantry rotation, O-ring rotation and MU were highly accurate and stable throughout the course of treatment. The daily dosimetric errors due to mechanical errors were small. VMDWAT provided high delivery accuracy and stability throughout the course of treatment. TRIAL REGISTRATION UMIN000023870 . Registered: 1 October 2016.
Collapse
Affiliation(s)
- Hideaki Hirashima
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan. .,Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan.
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Megumi Uto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Kiyonao Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|
14
|
Hirashima H, Nakamura M, Miyabe Y, Mukumoto N, Uto M, Nakamura K, Mizowaki T, Hiraoka M. Geometric and dosimetric quality assurance using logfiles and a 3D helical diode detector for Dynamic WaveArc. Phys Med 2017; 43:107-113. [PMID: 29195552 DOI: 10.1016/j.ejmp.2017.10.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2017] [Revised: 09/20/2017] [Accepted: 10/26/2017] [Indexed: 12/28/2022] Open
Abstract
PURPOSE To conduct patient-specific geometric and dosimetric quality assurance (QA) for the Dynamic WaveArc (DWA) using logfiles and ArcCHECK (Sun Nuclear Inc., Melbourne, FL, USA). METHODS Twenty DWA plans, 10 for pituitary adenoma and 10 for prostate cancer, were created using RayStation version 4.7 (RaySearch Laboratories, Stockholm, Sweden). Root mean square errors (RMSEs) between the actual and planned values in the logfiles were evaluated. Next, the dose distributions were reconstructed based on the logfiles. The differences between dose-volumetric parameters in the reconstructed plans and those in the original plans were calculated. Finally, dose distributions were assessed using ArcCHECK. In addition, the reconstructed dose distributions were compared with planned ones. RESULTS The means of RMSEs for the gantry, O-ring, MLC position, and MU for all plans were 0.2°, 0.1°, 0.1 mm, and 0.4 MU, respectively. Absolute means of the change in PTV D99% were 0.4 ± 0.4% and 0.1 ± 0.1% points between the original and reconstructed plans for pituitary adenoma and prostate cancer, respectively. The mean of the gamma passing rate (3%/3 mm) between the measured and planned dose distributions was 97.7%. In addition, that between the reconstructed and planned dose distributions was 99.6%. CONCLUSIONS We have demonstrated that the geometric accuracy and gamma passing rates were within AAPM 119 and 142 criteria during DWA. Dose differences in the dose-volumetric parameters using the logfile-based dose reconstruction method were also clinically acceptable in DWA.
Collapse
Affiliation(s)
- Hideaki Hirashima
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan.
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Megumi Uto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Kiyonao Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| |
Collapse
|
15
|
Ono T, Miyabe Y, Takahashi K, Akimoto M, Mukumoto N, Ishihara Y, Nakamura M, Mizowaki T, Hiraoka M. Geometric and dosimetric accuracy of dynamic tumor tracking during volumetric-modulated arc therapy using a gimbal mounted linac. Radiother Oncol 2017; 129:166-172. [PMID: 29137808 DOI: 10.1016/j.radonc.2017.10.034] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Revised: 10/26/2017] [Accepted: 10/27/2017] [Indexed: 12/25/2022]
Abstract
PURPOSE The aim was to examine the feasibility of a dynamic tumor-tracking volumetric modulated arc therapy (DTT-VMAT) technique using a gimbal-mounted linac and assess its positional, mechanical and dosimetric accuracy. MATERIALS AND METHODS DTT-VMAT was performed using a surrogated signal-based technique. The positional tracking accuracy was evaluated as the difference between the predicted and detected target positions for various wave patterns. Mechanical accuracy measurements included gantry, multileaf collimator (MLC) and gimbal positions. The differences between the command and the measured positions were evaluated for various wave patterns. Dosimetric verification was performed using Gafchromic EBT3 films in the benchmark phantom and two clinical cases. RESULTS The root mean square error (RMSE) of the positional accuracy was within 0.31 mm. The RMSE of mechanical accuracy was within 0.14° for the gantry, 0.11 ± 0.02 mm for the MLC and 0.13 mm for the gimbal positions. The passing rate of the 3%/3 mm gamma index was greater than 83.3% and 91.2% for the benchmark phantom and two clinical cases, respectively. CONCLUSIONS The positional, mechanical and dosimetric accuracy of DTT-VMAT were evaluated. DTT-VMAT with a gimbal-mounted linac had sufficient accuracy and presents a new strategy for treatment of several tumors with respiratory motion.
Collapse
Affiliation(s)
- Tomohiro Ono
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan; Department of Radiation Oncology, Wakayama Red Cross Hospital, Japan
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan.
| | - Kunio Takahashi
- Advanced Mechanical Systems Department, Mitsubishi Heavy Industries Ltd, Hiroshima, Japan
| | - Mami Akimoto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan
| | - Yoshitomo Ishihara
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Japan; Department of Radiation Oncology, Wakayama Red Cross Hospital, Japan
| |
Collapse
|
16
|
Uto M, Mizowaki T, Ogura K, Miyabe Y, Nakamura M, Mukumoto N, Hirashima H, Hiraoka M. Volumetric modulated Dynamic WaveArc therapy reduces the dose to the hippocampus in patients with pituitary adenomas and craniopharyngiomas. Pract Radiat Oncol 2017; 7:382-387. [PMID: 28666908 DOI: 10.1016/j.prro.2017.04.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2016] [Revised: 03/26/2017] [Accepted: 04/08/2017] [Indexed: 10/19/2022]
Abstract
PURPOSE Reducing the radiation dose to the hippocampus is important to preserve cognitive function in patients with brain tumors. The Vero4DRT system can realize a new irradiation technique, termed volumetric-modulated Dynamic WaveArc therapy (VMDWAT), which allows the safe use of sequential noncoplanar volumetric-modulated beams without couch rotation. Because VMDWAT appears to reduce the hippocampal dose in patients with pituitary adenomas and craniopharyngiomas, we performed a planning study to compare the dose distribution of volumetric-modulated arc therapy using only a coplanar arc (coVMAT) and VMDWAT. METHODS AND MATERIALS CoVMAT and VMDWAT plans were created for 30 patients with pituitary adenomas and craniopharyngiomas. The prescription dose was 52.2 Gy in 29 fractions, with 99% of each planning target volume covered by 90% of the prescribed dose. Optimization was performed for maximal reduction of the dose to the hippocampus. Treatment time was defined as the beam-on time. RESULTS The mean equivalent dose in 2 Gy fractions to 40% of the volume of the bilateral hippocampus (EQD40%) for coVMAT/VMDWAT were 9.90/5.31 Gy, respectively (P < .001). The mean EQD40% in VMDWAT was less than 7.3 Gy, which is the threshold for predicting cognitive impairment. Although the volume of normal brain receiving 5 Gy (V5) was significantly larger in VMDWAT, compared with coVMAT, the normal brain volume receiving 10, 15, 20, 25, 30, 35, 40, 45, and 50 Gy (V10-50) was significantly smaller in VMDWAT. The conformity and homogeneity indices were significantly better in VMDWAT. The mean VMDWAT treatment time was longer compared with coVMAT (70.1 vs 67.1 seconds, respectively). CONCLUSIONS Although VMDWAT increased brain V5 and the treatment time compared with coVMAT, it significantly reduced the dose to the hippocampus and brain V10 to V50 and improved target conformity and homogeneity. VMDWAT could be a promising treatment technique for pituitary adenomas and craniopharyngiomas.
Collapse
Affiliation(s)
- Megumi Uto
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan.
| | - Kengo Ogura
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan
| | - Hideaki Hirashima
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan
| |
Collapse
|
17
|
Burghelea M, Verellen D, Dhont J, Hung C, Gevaert T, Van den Begin R, Collen C, Poels K, Tournel K, Boussaer M, Jaudet C, Reynders T, Simon V, de Ridder M. Treating patients with Dynamic Wave Arc: First clinical experience. Radiother Oncol 2017; 122:347-351. [DOI: 10.1016/j.radonc.2017.01.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 01/02/2017] [Accepted: 01/03/2017] [Indexed: 11/30/2022]
|
18
|
Smyth G, Evans PM, Bamber JC, Mandeville HC, Welsh LC, Saran FH, Bedford JL. Non-coplanar trajectories to improve organ at risk sparing in volumetric modulated arc therapy for primary brain tumors. Radiother Oncol 2016; 121:124-131. [PMID: 27481571 DOI: 10.1016/j.radonc.2016.07.014] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2016] [Revised: 07/18/2016] [Accepted: 07/19/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND AND PURPOSE To evaluate non-coplanar volumetric modulated arc radiotherapy (VMAT) trajectories for organ at risk (OAR) sparing in primary brain tumor radiotherapy. MATERIALS AND METHODS Fifteen patients were planned using coplanar VMAT and compared against non-coplanar VMAT plans for three trajectory optimization techniques. A geometric heuristic technique (GH) combined beam scoring and Dijkstra's algorithm to minimize the importance-weighted sum of OAR volumes irradiated. Fluence optimization was used to perform a local search around coplanar and GH trajectories, producing fluence-based local search (FBLS) and FBLS+GH trajectories respectively. RESULTS GH, FBLS, and FBLS+GH trajectories reduced doses to the contralateral globe, optic nerve, hippocampus, temporal lobe, and cochlea. However, FBLS increased dose to the ipsilateral lens, optic nerve and globe. Compared to GH, FBLS+GH increased dose to the ipsilateral temporal lobe and hippocampus, contralateral optics, and the brainstem and body. GH and FBLS+GH trajectories reduced bilateral hippocampi normal tissue complication probability (p=0.028 and p=0.043, respectively). All techniques reduced PTV conformity; GH and FBLS+GH trajectories reduced homogeneity but less so for FBLS+GH. CONCLUSIONS The geometric heuristic technique best spared OARs and reduced normal tissue complication probability, however incorporating fluence information into non-coplanar trajectory optimization maintained PTV homogeneity.
Collapse
Affiliation(s)
- Gregory Smyth
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom.
| | - Philip M Evans
- Centre for Vision, Speech and Signal Processing, University of Surrey, Guildford, United Kingdom
| | - Jeffrey C Bamber
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | | | - Liam C Welsh
- The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Frank H Saran
- The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - James L Bedford
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
19
|
Burghelea M, Verellen D, Poels K, Hung C, Nakamura M, Dhont J, Gevaert T, Van den Begin R, Collen C, Matsuo Y, Kishi T, Simon V, Hiraoka M, de Ridder M. Initial characterization, dosimetric benchmark and performance validation of Dynamic Wave Arc. Radiat Oncol 2016; 11:63. [PMID: 27130434 PMCID: PMC4850693 DOI: 10.1186/s13014-016-0633-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Accepted: 04/12/2016] [Indexed: 11/10/2022] Open
Abstract
Background Dynamic Wave Arc (DWA) is a clinical approach designed to maximize the versatility of Vero SBRT system by synchronizing the gantry-ring noncoplanar movement with D-MLC optimization. The purpose of this study was to verify the delivery accuracy of DWA approach and to evaluate the potential dosimetric benefits. Methods DWA is an extended form of VMAT with a continuous varying ring position. The main difference in the optimization modules of VMAT and DWA is during the angular spacing, where the DWA algorithm does not consider the gantry spacing, but only the Euclidian norm of the ring and gantry angle. A preclinical version of RayStation v4.6 (RaySearch Laboratories, Sweden) was used to create patient specific wave arc trajectories for 31 patients with various anatomical tumor regions (prostate, oligometatstatic cases, centrally-located non-small cell lung cancer (NSCLC) and locally advanced pancreatic cancer-LAPC). DWA was benchmarked against the current clinical approaches and coplanar VMAT. Each plan was evaluated with regards to dose distribution, modulation complexity (MCS), monitor units and treatment time efficiency. The delivery accuracy was evaluated using a 2D diode array that takes in consideration the multi-dimensionality of DWA during dose reconstruction. Results In centrally-located NSCLC cases, DWA improved the low dose spillage with 20 %, while the target coverage was increased with 17 % compared to 3D CRT. The structures that significantly benefited from using DWA were proximal bronchus and esophagus, with the maximal dose being reduced by 17 % and 24 %, respectively. For prostate and LAPC, neither technique seemed clearly superior to the other; however, DWA reduced with more than 65 % of the delivery time over IMRT. A steeper dose gradient outside the target was observed for all treatment sites (p < 0.01) with DWA. Except the oligometastatic cases, where the DWA-MCSs indicate a higher modulation, both DWA and VMAT modalities provide plans of similar complexity. The average ɣ (3 % /3 mm) passing rate for DWA plans was 99.2 ± 1 % (range from 96.8 to 100 %). Conclusions DWA proven to be a fully functional treatment technique, allowing additional flexibility in dose shaping, while preserving dosimetrically robust delivery and treatment times comparable with coplanar VMAT. Electronic supplementary material The online version of this article (doi:10.1186/s13014-016-0633-7) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Manuela Burghelea
- Department of Radiotherapy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, B-1090, Brussels, Belgium. .,R&D Radiosurgery, BrainLAB AG, Munich, Germany. .,Babes Bolyai University, Faculty of Physics, Cluj-Napoca, Romania.
| | - Dirk Verellen
- Department of Radiotherapy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, B-1090, Brussels, Belgium
| | - Kenneth Poels
- Department of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium
| | | | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Jennifer Dhont
- Department of Radiotherapy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, B-1090, Brussels, Belgium
| | - Thierry Gevaert
- Department of Radiotherapy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, B-1090, Brussels, Belgium
| | - Robbe Van den Begin
- Department of Radiotherapy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, B-1090, Brussels, Belgium
| | - Christine Collen
- Department of Radiotherapy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, B-1090, Brussels, Belgium
| | - Yukinori Matsuo
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Takahiro Kishi
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Viorica Simon
- Babes Bolyai University, Faculty of Physics, Cluj-Napoca, Romania
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Mark de Ridder
- Department of Radiotherapy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, B-1090, Brussels, Belgium
| |
Collapse
|
20
|
Burghelea M, Verellen D, Poels K, Gevaert T, Depuydt T, Tournel K, Hung C, Simon V, Hiraoka M, de Ridder M. Geometric Verification of Dynamic Wave Arc Delivery With the Vero System Using Orthogonal X-ray Fluoroscopic Imaging. Int J Radiat Oncol Biol Phys 2015; 92:754-61. [DOI: 10.1016/j.ijrobp.2015.02.053] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2014] [Revised: 12/22/2014] [Accepted: 02/26/2015] [Indexed: 11/24/2022]
|
21
|
Sato S, Miyabe Y, Takahashi K, Yamada M, Nakamura M, Ishihara Y, Yokota K, Kaneko S, Mizowaki T, Monzen H, Hiraoka M. Commissioning and quality assurance of Dynamic WaveArc irradiation. J Appl Clin Med Phys 2015; 16:5080. [PMID: 26103177 PMCID: PMC5690069 DOI: 10.1120/jacmp.v16i2.5080] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Revised: 12/10/2014] [Accepted: 12/08/2014] [Indexed: 11/23/2022] Open
Abstract
A novel three‐dimensional unicursal irradiation technique “Dynamic WaveArc” (DWA), which employs simultaneous and continuous gantry and O‐ring rotation during dose delivery, has been implemented in Vero4DRT. The purposes of this study were to develop a commissioning and quality assurance procedure for DWA irradiation, and to assess the accuracy of the mechanical motion and dosimetric control of Vero4DRT. To determine the mechanical accuracy and the dose accuracy with DWA irradiation, 21 verification test patterns with various gantry and ring rotational directions and speeds were generated. These patterns were irradiated while recording the irradiation log data. The differences in gantry position, ring position, and accumulated MU (EG,ER, and EMU, respectively) between the planned and actual values in the log at each time point were evaluated. Furthermore, the doses delivered were measured using an ionization chamber and spherical phantom. The constancy of radiation output during DWA irradiation was examined by comparison with static beam irradiation. The mean absolute error (MAE) of EG and ER were within 0.1° and the maximum error was within 0.2°. The MAE of EMU was within 0.7 MU, and maximum error was 2.7 MU. Errors of accumulated MU were observed only around control points, changing gantry, and ring velocity. The gantry rotational range, in which EMU was greater than or equal to 2.0 MU, was not greater than 3.2%. It was confirmed that the extent of the large differences in accumulated MU was negligibly small during the entire irradiation range. The variation of relative output value for DWA irradiation was within 0.2%, and this was equivalent to conventional arc irradiation with a rotating gantry. In conclusion, a verification procedure for DWA irradiation was designed and implemented. The results demonstrated that Vero4DRT has adequate mechanical accuracy and beam output constancy during gantry and ring rotation. PACS number: 87
Collapse
Affiliation(s)
- Sayaka Sato
- Graduate School of Medicine, Kyoto University.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Utilization of intensity-modulated radiation therapy and image-guided radiation therapy in pancreatic cancer: is it beneficial? Semin Radiat Oncol 2014; 24:132-9. [PMID: 24635870 DOI: 10.1016/j.semradonc.2013.11.003] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The recent development of intensity-modulated radiation therapy (IMRT) and improvements in image-guided radiotherapy (IGRT) have provided considerable advances in the utilization of radiation therapy (RT) for the management of pancreatic cancer. IGRT allows for the reduction of treatment volumes, potentially less chance of a marginal miss, and quality assurance of gastrointestinal filling, while IMRT has been shown to reduce both sudden and late side effects compared with 3-dimensional conformal RT. Here, we review published data and provide essential recommendations on the utilization of IMRT and IGRT for the management of patients with pancreatic cancer.
Collapse
|
23
|
Ogura K, Mizowaki T, Ishida Y, Hiraoka M. Dosimetric advantages of O-ring design radiotherapy system for skull-base tumors. J Appl Clin Med Phys 2014; 15:4608. [PMID: 24710448 PMCID: PMC5875486 DOI: 10.1120/jacmp.v15i2.4608] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2013] [Revised: 12/03/2013] [Accepted: 12/02/2013] [Indexed: 12/25/2022] Open
Abstract
The purpose of this study was to investigate whether a new O‐ring design radiotherapy delivery system has advantages in radiotherapy planning for skull‐base tumors. Twenty‐five patients with skull‐base tumors were included in this study. Two plans were made using conventional (Plan A) or new (Plan B) techniques. Plan A consisted of four dynamic conformal arcs (DCAs): two were horizontal, and the other two were from cranial directions. Plan B was created by converting horizontal arcs to those from caudal directions making use of the O‐ring design radiotherapy system. The micromultileaf collimators were fitted to cover at least 99% of the planning target volume with prescribed doses, 90% of the dose at the isocenter. The two plans were compared in terms of target homogeneity, conformity, and irradiated volume of normal tissues, using a two‐sided paired t‐test. For evaluation regarding target coverage, the homogeneity indices defined by the International Commission on Radiation Units and Measurements 83 were 0.099±0.010 (mean ± standard deviation) and 0.092±0.010, the conformity indices defined by the Radiation Therapy Oncology Group were 1.720±0.249 and 1.675±0.239, and the Paddick's conformity indices were 0.585±0.078 and 0.602±0.080, in Plans A and B, respectively. For evaluation of irradiated normal tissue, the Paddick's gradient indices were 3.118±0.283 and 2.938±0.263 in Plans A and B, respectively. All of these differences were statistically significant (p‐values <0.05). The mean doses of optic nerves, eyes, brainstem, and hippocampi were also significantly lower in Plan B. The DCA technique from caudal directions using the new O‐ring design radiotherapy system can improve target homogeneity and conformity compared with conventional DCA techniques, and can also decrease the volume of surrounding normal tissues that receives moderate doses. PACS numbers: 87.55.‐x, 87.55.D‐, 87.55.dk
Collapse
Affiliation(s)
- Kengo Ogura
- Graduate School of Medicine Kyoto University.
| | | | | | | |
Collapse
|
24
|
Ono T, Miyabe Y, Yamada M, Shiinoki T, Sawada A, Kaneko S, Monzen H, Mizowaki T, Kokubo M, Hiraoka M. Geometric and dosimetric accuracy of dynamic tumor-tracking conformal arc irradiation with a gimbaled x-ray head. Med Phys 2014; 41:031705. [DOI: 10.1118/1.4864242] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
|
25
|
Smyth G, Bamber JC, Evans PM, Bedford JL. Trajectory optimization for dynamic couch rotation during volumetric modulated arc radiotherapy. Phys Med Biol 2013; 58:8163-77. [PMID: 24200876 DOI: 10.1088/0031-9155/58/22/8163] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Non-coplanar radiation beams are often used in three-dimensional conformal and intensity modulated radiotherapy to reduce dose to organs at risk (OAR) by geometric avoidance. In volumetric modulated arc radiotherapy (VMAT) non-coplanar geometries are generally achieved by applying patient couch rotations to single or multiple full or partial arcs. This paper presents a trajectory optimization method for a non-coplanar technique, dynamic couch rotation during VMAT (DCR–VMAT), which combines ray tracing with a graph search algorithm. Four clinical test cases (partial breast, brain, prostate only, and prostate and pelvic nodes) were used to evaluate the potential OAR sparing for trajectory-optimized DCR–VMAT plans, compared with standard coplanar VMAT. In each case, ray tracing was performed and a cost map reflecting the number of OAR voxels intersected for each potential source position was generated. The least-cost path through the cost map, corresponding to an optimal DCR–VMAT trajectory, was determined using Dijkstra's algorithm. Results show that trajectory optimization can reduce dose to specified OARs for plans otherwise comparable to conventional coplanar VMAT techniques. For the partial breast case, the mean heart dose was reduced by 53%. In the brain case, the maximum lens doses were reduced by 61% (left) and 77% (right) and the globes by 37% (left) and 40% (right). Bowel mean dose was reduced by 15% in the prostate only case. For the prostate and pelvic nodes case, the bowel V50 Gy and V60 Gy were reduced by 9% and 45% respectively. Future work will involve further development of the algorithm and assessment of its performance over a larger number of cases in site-specific cohorts.
Collapse
|