1
|
Quoc SD, Fujibuchi T, Arakawa H, Hamada K. Simulating the head of a TrueBeam linear particle accelerator and calculating the photoneutron spectrum on the central axis of a 10-MV photon using particle and heavy-ion transport system code. RADIATION PROTECTION DOSIMETRY 2024; 200:779-790. [PMID: 38767288 DOI: 10.1093/rpd/ncae124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 03/15/2024] [Accepted: 05/06/2024] [Indexed: 05/22/2024]
Abstract
Photon energy is higher than the (γ,n) threshold, allowing it to interact with the nuclei of materials with high z properties and liberate fast neutrons. This represents a potentially harmful source of radiation for humans and the environment. This study validated the Monte Carlo simulation, using the particle and heavy-ion transport code system (PHITS) on a TrueBeam 10-MV linear particle accelerator's head shielding model and then used this PHITS code to simulate a photo-neutron spectrum for the transport of the beam. The results showed that, when comparing the simulated to measured PDD and crosslines, 100% of the γ-indexes were <1 (γ3%/3mm) for both simulations, for both phase-space data source and a mono energy source. Neutron spectra were recorded in all parts of the TrueBeam's head, as well as photon neutron spectra at three points on the beamline.
Collapse
Affiliation(s)
- Soai Dang Quoc
- Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Toshioh Fujibuchi
- Division of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Fukuoka 812-8582, Japan
| | - Hiroyuki Arakawa
- Division of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Fukuoka 812-8582, Japan
| | - Keisuke Hamada
- Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
- Department of Radiological Technology, National Hospital Organization Kyushu Cancer Center, 3-1-1 Notame Minami-ku, Fukuoka, Fukuoka 811-1395, Japan
| |
Collapse
|
2
|
Höfel S, Zwicker F, Fix MK, Drescher M. Towards liquid EPR dosimetry using nitroxides in aqueous solution. Phys Med Biol 2024; 69:055026. [PMID: 38306975 DOI: 10.1088/1361-6560/ad25c4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 02/01/2024] [Indexed: 02/04/2024]
Abstract
Objective. Water-equivalent dosimeters are desirable for dosimetry in radiotherapy. The present work investigates basic characteristics of novel aqueous detector materials and presents a signal loss approach for electron paramagnetic resonance (EPR) dosimetry.Approach. The proposed principle is based on the radiation dose dependent annihilation of EPR active nitroxides (NO·) in aqueous solutions. Stable nitroxide radicals (3-Maleimido-2,2,5,5-tetramethyl-1-pyrrolidinyloxy (MmP), 3-Carbamoyl-2,2,5,5-tetramethyl-1-pyrrolidinyloxy (CmP)) in aqueous solutions containing dimethyl sulfoxide (DMSO) as an additive were filled in glass capillaries for irradiation and EPR readout. Radiation doses ranging from 1 to 64 Gy were applied with a clinical 6 MV flattening filter free photon beam. EPR readout was then performed with a X-band benchtop spectrometer. The dose response, temporal stability and reproducibility of the samples' EPR signal amplitudes as well as the influence of the nitroxide concentration between 10 and 160μM on the absolute signal loss were investigated using MmP. CmP was used to examine the dependence of the dose response on DMSO concentration between 0 and 10 vol%. An indirect effect model was fitted to the experimental data assuming irradiation induced radical reactions as the underlying mechanism.Main results. For an initial MmP concentration of 20μM, absolute EPR signal loss is linear up to a dose of 16 Gy with a yield G(-NO·) of approximately 0.4μmol J-1. Within five weeks upon sample irradiation to doses between 0 and 32 Gy relative EPR signal fluctuations were on average (126 readouts) below 1% (1σ). For c(MmP) ≥ 20μM, absolute signal loss is only weakly dependent on c(MmP), whereas it increases strongly with increasing c(DMSO) in the range 0-5 vol%. An indirect effect model is applicable to describe the reaction mechanism resulting in the observed dose response curve.Significance. Liquids consisting of nitroxides in aqueous solution and small amounts of DMSO (2 vol%) show promising basic characteristics for application as water-equivalent EPR dosimeter materials in radiotherapy. The EPR signal loss is based on an indirect effect mediated by diffusing radicals originating from the radiolysis of the water/DMSO mixture.
Collapse
Affiliation(s)
- Sebastian Höfel
- Department of Chemistry and Konstanz Research School Chemical Biology, University of Konstanz, Konstanz, Germany
- Klinik und Praxis für Strahlentherapie am Klinikum Konstanz, Konstanz, Germany
| | - Felix Zwicker
- Klinik und Praxis für Strahlentherapie am Klinikum Konstanz, Konstanz, Germany
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Clinical Cooperation Unit Molecular Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Michael K Fix
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Switzerland
| | - Malte Drescher
- Department of Chemistry and Konstanz Research School Chemical Biology, University of Konstanz, Konstanz, Germany
| |
Collapse
|
3
|
Tang C, Yuan J, Guo H, Dai Z, Liu B, Xi H, He J, Niu S. Quantify the Effect of Air Gap Errors on Skin Dose for Breast Cancer Radiotherapy. Technol Cancer Res Treat 2024; 23:15330338241258566. [PMID: 38803305 PMCID: PMC11135118 DOI: 10.1177/15330338241258566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2024] Open
Abstract
Purpose: Determining the impact of air gap errors on the skin dose in postoperative breast cancer radiotherapy under dynamic intensity-modulated radiation therapy (IMRT) techniques. Methods: This was a retrospective study that involved 55 patients who underwent postoperative radiotherapy following modified radical mastectomy. All plans employed tangential IMRT, with a prescription dose of 50 Gy, and bolus added solely to the chest wall. Simulated air gap depth errors of 2 mm, 3 mm, and 5 mm were introduced at depression or inframammary fold areas on the skin, resulting in the creation of air gaps named Air2, Air3, and Air5. Utilizing a multivariable GEE, the average dose (Dmean) of the local skin was determined to evaluate its relationship with air gap volume and the lateral beam's average angle (AALB). Additionally, an analysis was conducted on the impact of gaps on local skin. Results: When simulating an air gap depth error of 2 mm, the average Dmean in plan2 increased by 0.46 Gy compared to the initial plan (planO) (p < .001). For the 3-mm air gap, the average Dmean of plan3 was 0.51 Gy higher than that of planO (p < .001). When simulating the air gap as 5 mm, the average Dmean of plan5 significantly increased by 0.59 Gy compared to planO (p < .001). The TCP results showed a similar trend to those of Dmean. As the depth of air gap error increases, NTCP values also gradually rise. The linear regression of the multivariable GEE equation indicates that the volume of air gaps and the AALB are strong predictors of Dmean. Conclusion: With small irregular air gap errors simulated in 55 patients, the values of skin's Dmean, TCP, and NTCP increased. A multivariable linear GEE regression model may effectively explain the impact of air gap volume and AALB on the local skin.
Collapse
Affiliation(s)
- Chunbo Tang
- Department of Radiation Oncology, First Affiliated Hospital of Gannan Medical University, Ganzhou, China
- Jiangxi Clinical Research Center for Cancer, Ganzhou, China
| | - Jun Yuan
- Department of Radiation Oncology, First Affiliated Hospital of Gannan Medical University, Ganzhou, China
- Jiangxi Clinical Research Center for Cancer, Ganzhou, China
| | - Hailiang Guo
- Department of Radiation Oncology, First Affiliated Hospital of Gannan Medical University, Ganzhou, China
- Jiangxi Clinical Research Center for Cancer, Ganzhou, China
| | - Zhongyang Dai
- Department of Radiation Oncology, First Affiliated Hospital of Gannan Medical University, Ganzhou, China
- Jiangxi Clinical Research Center for Cancer, Ganzhou, China
| | - Biaoshui Liu
- Department of Radiation Oncology, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Haiyan Xi
- Department of Radiation Oncology, Nanchang People's Hospital, Nanchang, China
| | - Ji He
- School of Biomedical Engineering, Fourth Affiliated Hospital of Guangzhou, Guangzhou Medical University, Guangzhou, China
| | - Shanzhou Niu
- School of Mathematics and Computer Science / Ganzhou Key Laboratory of Computational Imaging, Gannan Normal University, Ganzhou, China
| |
Collapse
|
4
|
Zhang C, Lewin W, Cullen A, Thommen D, Hill R. Evaluation of 3D-printed bolus for radiotherapy using megavoltage X-ray beams. Radiol Phys Technol 2023; 16:414-421. [PMID: 37294521 PMCID: PMC10435601 DOI: 10.1007/s12194-023-00727-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 05/27/2023] [Accepted: 05/29/2023] [Indexed: 06/10/2023]
Abstract
A radiotherapy bolus is a tissue-equivalent material placed on the skin to adjust the surface dose of megavoltage X-ray beams used for treatment. In this study, the dosimetric properties of two 3D-printed filament materials, polylactic acid (PLA) and thermoplastic polyether urethane (TPU), used as radiotherapy boluses, were investigated. The dosimetric properties of PLA and TPU were compared with those of several conventional bolus materials and RMI457 Solid Water. Percentage depth-dose (PDD) measurements in the build-up region were performed for all materials using 6 and 10 MV photon treatment beams on Varian linear accelerators. The results showed that the differences in the PDDs of the 3D-printed materials from the RMI457 Solid Water were within 3%, whereas those of the dental wax and SuperFlab gel materials were within 5%. This indicates that PLA and TPU 3D-printed materials are suitable radiotherapy bolus materials.
Collapse
Affiliation(s)
- Chunsu Zhang
- Institute of Medical Physics, School of Physics, The University of Sydney, Sydney, NSW, 2006, Australia
- Arto Hardy Family Biomedical Innovation Hub, Chris O'Brien Lifehouse, Camperdown, NSW, 2050, Australia
| | - Will Lewin
- Arto Hardy Family Biomedical Innovation Hub, Chris O'Brien Lifehouse, Camperdown, NSW, 2050, Australia
| | - Ashley Cullen
- Institute of Medical Physics, School of Physics, The University of Sydney, Sydney, NSW, 2006, Australia
- Arto Hardy Family Biomedical Innovation Hub, Chris O'Brien Lifehouse, Camperdown, NSW, 2050, Australia
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Missenden Rd, Camperdown,Sydney, NSW, 2050, Australia
| | - Daniel Thommen
- Institute of Medical Physics, School of Physics, The University of Sydney, Sydney, NSW, 2006, Australia
- Arto Hardy Family Biomedical Innovation Hub, Chris O'Brien Lifehouse, Camperdown, NSW, 2050, Australia
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Missenden Rd, Camperdown,Sydney, NSW, 2050, Australia
| | - Robin Hill
- Institute of Medical Physics, School of Physics, The University of Sydney, Sydney, NSW, 2006, Australia.
- Arto Hardy Family Biomedical Innovation Hub, Chris O'Brien Lifehouse, Camperdown, NSW, 2050, Australia.
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Missenden Rd, Camperdown,Sydney, NSW, 2050, Australia.
| |
Collapse
|
5
|
Mahur M, Singh M, Gurjar OP, Semwal MK. Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code. J Biomed Phys Eng 2022; 12:455-464. [PMID: 36313413 PMCID: PMC9589075 DOI: 10.31661/jbpe.v0i0.2101-1274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 05/25/2021] [Indexed: 11/06/2022]
Abstract
Background: Accurate assessment of surface and build-up doses has a key role in radiotherapy, especially for the superficial lesions with uncertainties involved while performing measurements in the build-up region. Objective: This study aimed to assess surface and build-up doses for 6 MV photon beam from linear accelerator using parallel plate ionization chamber, EBT3 Gafchromic films, and PRIMO Monte Carlo (MC) simulation code. Material and Methods: In this experimental study, parallel plate chamber (PPC05) and EBT3 Gafchromic films were used to measure doses in a build-up region for 6 MV beam from the linear accelerator for different field sizes at various depths ranging from 0 to 2 cm from the surface with 100 cm source to surface distance (SSD) in a solid water phantom. Measured results were compared with Monte Carlo simulated results using PENELOPE-based PRIMO simulation code for the same setup conditions. Effect of gantry angle incidence and SSD were also analyzed for depth doses at the surface and build-up regions using PPC05 ion chamber and EBT3 Gafchromic films. Results: Doses measured at the surface were 14.78%, 19.87%, 25.83%, and 31.54% for field sizes of 5×5, 10×10, 15×15, and 20×20 cm2, respectively for a 6 MV photon beam with a parallel plate chamber and 14.20%, 19.14%, 25.149%, and 30.90%, respectively for EBT3 Gafchromic films. Both measurement sets were in good agreement with corresponding simulated results from the PRIMO MC simulation code; doses increase with the increase in field sizes. Conclusion: Good agreement was observed between the measured depth doses using parallel plate ionization chamber, EBT3 Gafchromic films, and the simulated depth doses using PRIMO Monte Carlo simulation code.
Collapse
Affiliation(s)
- Mamta Mahur
- MSc, Department of Radiation Oncology, Delhi State Cancer Institute, Dilshad Garden, Delhi, India
- MSc, Department of Physics, School of Basic Sciences and Research, Sharda University, Greater Noida, Uttar Pradesh, India
| | - Munendra Singh
- PhD, Department of Physics, School of Basic Sciences and Research, Sharda University, Greater Noida, Uttar Pradesh, India
| | - Om Prakash Gurjar
- PhD, Government Cancer Hospital, Mahatma Gandhi Memorial Medical College, Indore-452001, India
| | - Manoj Kumar Semwal
- PhD, Department of Radiation Oncology, Army Hospital (Research & Referral), Delhi Cantonment New Delhi-110010, India
| |
Collapse
|
6
|
Investigation of the effects of the step size of Geant4 electromagnetic physics on the depth dose simulation of a small field proton beam. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
7
|
Dose divergence between monte carlo simulation and experimental measurements in the build-up region for a photon beam. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109643] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
8
|
Surface dose and build-up region depth dose measurements in non-standard beams of Cyberknife and tomotherapy systems. Radiol Phys Technol 2021; 14:309-317. [PMID: 34224082 DOI: 10.1007/s12194-021-00629-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 06/26/2021] [Accepted: 06/28/2021] [Indexed: 10/20/2022]
Abstract
The purpose of this study was to measure the surface dose and build-up region depth dose characteristics of 6 MV photon beams in Cyberknife and helical tomotherapy (HT) systems for non-standard small fields using parallel plate chambers (Roos and Markus), Gafchromic EBT3 films, and nanoDot optically stimulated luminescence dosimeters (OSLDs), as well as to investigate the effect of oblique incidence on the surface dose of the beam. All measurements were conducted in a virtual water phantom under machine-specific reference conditions. The Roos and OSLDs overestimated the surface dose when compared with the Markus chamber and EBT3 films by 20%. We applied water equivalent thickness (WET) correction to account for the intrinsic build-up thickness of the detectors from their effective point of measurement (EPOM). With WET correction, a reasonably close surface dose estimate was obtained for all detectors, within 1.9% agreement for the 60 mm collimator of Cyberknife and 3.1% agreement for the HT system, with a 5 × 10 cm2 field size. The surface dose increased from the normally incident Cyberknife and HT fields with increasing angle of incidence. The surface dose increased to twice its value at normal incidence for highly oblique angles of incidence above 55°. For the tested fields, a reasonable surface dose estimate could be measured with the detectors if the correction for intrinsic buildup thickness was applied. Nevertheless, the use of Roos chambers with large dimensions and nanoDot OSLDs is not recommended for estimating the surface dose for small fields.
Collapse
|
9
|
Dwivedi S, Kansal S, Dangwal VK, Bharati A, Shukla J. Dosimetry of a 6 MV flattening filter-free small photon beam using various detectors. Biomed Phys Eng Express 2021; 7. [PMID: 33930875 DOI: 10.1088/2057-1976/abfd80] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Accepted: 04/30/2021] [Indexed: 11/12/2022]
Abstract
The present study aimed to dosimetrically evaluate the small-fields of a 6 MV flattening filter-free (FFF) photon beam using different detectors.The 6 MV FFF photon beam was used for measurement of output factor, depth dose, and beam profile of small-fields of sizes 0.6 cm × 0.6 cm to 6.0 cm × 6.0 cm. The five detectors used were SNC125c, PinPoint, EDGE, EBT3, and TLD-100. All measurements were performed as per the International Atomic Energy Agency TRS 483 protocol. Output factors measured using different detectors as direct reading ratios showed significant variation for the smallest fields, whereas after correcting them according to TRS 483, all sets of output factors were nearly compatible with each other when measurement uncertainty was also considered. The beam profile measured using SNC125c showed the largest penumbra for all field sizes, whereas the smallest was recorded with EDGE. Compared with that of EBT3, the surface dose was found to be much higher for all the other detectors. PinPoint, EBT3, TLD-100, and EDGE were found to be the detector of choice for small-field output factor measurements; however, PinPoint needs special attention when used for the smallest field size (0.6 cm × 0.6 cm). EDGE and EBT3 are optimal for measuring beam profiles. EBT3, PinPoint, and EDGE can be selected for depth dose measurements, and EBT3 is suitable for surface dose estimation.
Collapse
Affiliation(s)
- Shekhar Dwivedi
- Department of Medical Physics, Tata Memorial Centre, Homi Bhabha Cancer Hospital and Research Centre, Mullanpur, Mohali, Punjab, 140901, India.,Department of Physics, Maharaja Ranjit Singh Punjab Technical University, Bathinda, Punjab, 151001, India
| | - Sandeep Kansal
- Department of Physics, Maharaja Ranjit Singh Punjab Technical University, Bathinda, Punjab, 151001, India
| | - Vinod Kumar Dangwal
- Department of Radiotherapy, Government Medical College, Patiala, Punjab, 147001, India
| | - Avinav Bharati
- Department of Radiation Oncology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, 226010, India
| | - Jooli Shukla
- Department of Physics, Dr Bhimrao Ambedkar University, Agra, Uttar Pradesh, 282004, India
| |
Collapse
|
10
|
Patlan-Cardoso F, Rodríguez-Romo S, Ibáñez-Orozco O, Rodríguez-Vázquez K, Vergara-Martínez FJ. Estimation of the central-axis-reference percent depth dose in a water phantom using artificial intelligence. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2021. [DOI: 10.1080/16878507.2020.1857114] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Affiliation(s)
- Fernando Patlan-Cardoso
- Centro de Investigaciones Teóricas., Facultad de Estudios Superiores Cuautitlán, Universidad Nacional Autónoma de México, Cuautitlán Izcalli, México
| | - Suemi Rodríguez-Romo
- Centro de Investigaciones Teóricas., Facultad de Estudios Superiores Cuautitlán, Universidad Nacional Autónoma de México, Cuautitlán Izcalli, México
| | - Oscar Ibáñez-Orozco
- Centro de Investigaciones Teóricas., Facultad de Estudios Superiores Cuautitlán, Universidad Nacional Autónoma de México, Cuautitlán Izcalli, México
| | | | | |
Collapse
|
11
|
Ghazal M, Södergren L, Westermark M, Söderström J, Pommer T. Dosimetric and mechanical equivalency of Varian TrueBeam linear accelerators. J Appl Clin Med Phys 2020; 21:43-53. [PMID: 33070456 PMCID: PMC7769408 DOI: 10.1002/acm2.13058] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 09/17/2020] [Accepted: 09/22/2020] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To investigate and improve the level of equivalency of Varian TrueBeam linear accelerators (linacs) in energy-, dosimetric leaf gap- (DLG) and jaw calibration. METHODS Eight linacs with four photon energies: 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV, and three electron energies (on two linacs): 6, 9, and 12 MeV were commisioned and beam-matched. Initially, symmetry of lateral profiles was calibrated for maximum field size. Energy-matching was then performed for photons by adjusting diagonal profiles at maximum field size and depth of maximum dose to coincide with the reference linac, and for electrons by matching the range at percentage depth of ionization of 90%, 80%, and 50%. Calibration of DLG was performed for 6 MV and evaluated among the linacs. The relationship between DLG and the Gap value was investigated. A method using electronic portal imaging device (EPID) was developed and implemented for jaw calibration. RESULTS Symmetry calibration for photons (electrons) was within 1% (0.7%), further improving the vendor's acceptance criteria. Photon and electron energy-matching was within 0.5% and 0.1 mm, respectively. Calibration of DLG was within 0.032 mm among the linacs and utilizing the relationship between DLG and the Gap value resulted in an empirical calibration method which was implemented to simplify DLG adjustment. Using EPID-based method of calibration, evaluation of the jaw-positioning among the linacs for 30 cm × 30 cm field size was within 0.4 mm and in the junction area within 0.2 mm. Dose delivery error of VMAT-plans were at least 99.2% gamma pass rate (1%, 1 mm). CONCLUSIONS High level of equivalency, beyond clinically accepted criteria, of TrueBeam linacs could be achieved which reduced dose delivery systematic errors and increased confidence in interchanging patients among linacs.
Collapse
Affiliation(s)
- Mohammed Ghazal
- Department of Medical Radiation Physics and Nuclear MedicineKarolinska University HospitalStockholmSweden
| | - Lars Södergren
- Department of Medical Radiation Physics and Nuclear MedicineKarolinska University HospitalStockholmSweden
| | - Mathias Westermark
- Department of Medical Radiation Physics and Nuclear MedicineKarolinska University HospitalStockholmSweden
| | - Julia Söderström
- Department of Medical Radiation Physics and Nuclear MedicineKarolinska University HospitalStockholmSweden
| | - Tobias Pommer
- Department of Medical Radiation Physics and Nuclear MedicineKarolinska University HospitalStockholmSweden
- Department of Hematology, Oncology and Radiation PhysicsSkåne University HospitalLundSweden
| |
Collapse
|
12
|
Lobo D, Banerjee S, Srinivas C, Ravichandran R, Putha SK, Prakash Saxena PU, Reddy S, Sunny J. Influence of Air Gap under Bolus in the Dosimetry of a Clinical 6 MV Photon Beam. J Med Phys 2020; 45:175-181. [PMID: 33487930 PMCID: PMC7810143 DOI: 10.4103/jmp.jmp_53_20] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2020] [Revised: 08/16/2020] [Accepted: 08/23/2020] [Indexed: 12/02/2022] Open
Abstract
Aim: In some situations of radiotherapy treatments requiring application of tissue-equivalent bolus material (e.g., gel bolus), due to material's rigid/semi-rigid nature, undesirable air gaps may occur beneath it because of irregularity of body surface. The purpose of this study was to evaluate the dosimetric parameters such as surface dose (Ds), depth of dose maximum (dmax), and depth dose along central axis derived from the percentage depth dose (PDD) curve of a 6 MV clinical photon beam in the presence of air gaps between the gel bolus and the treatment surface. Materials and Methods: A bolus holder was designed to hold the gel bolus sheet to create an air gap between the bolus and the radiation field analyzer's (RFA-300) water surface. PDD curves were taken for field sizes of 5 cm × 5 cm, 10 cm × 10 cm, 15 cm × 15 cm, 20 cm × 20 cm, and 25 cm × 25 cm, with different thicknesses of gel bolus (0.5, 1.0, and 1.5 cm) and air gap (from 0.0 to 3.0 cm), using a compact ionization chamber (CC13) with RFA-300 keeping 100 cm source-to-surface (water) distance. The dosimetric parameters, for example, “Ds,“ “dmax,“ and difference of PDD (maximum air gap vs. nil air gap), were analyzed from the obtained PDD curves. Results: Compared to ideal conditions of full contact of bolus with water surface, it has been found that there is a reduction in “Ds“ ranging from 14.8% to 3.2%, 14.9% to 1.1%, and 12.6% to 0.7% with the increase of field size for 0.5, 1.0, and 1.5 cm thickness of gel boluses, respectively, for maximum air gap. The “dmax“ shows a trend of moving away from the treatment surface, and the maximum shift was observed for smaller field size with thicker bolus and greater air gap. The effect of air gap on PDD is minimal (≤1%) beyond 0.4 cm depth for all bolus thicknesses and field sizes except for 5 cm × 5 cm with 1.5 cm bolus thickness. Conclusions: The measured data can be used to predict the probable effect on therapeutic outcome due to the presence of inevitable air gaps between the bolus and the treatment surface.
Collapse
Affiliation(s)
- Dilson Lobo
- Department of Radiation Oncology, Kasturba Medical College (A Constituent Institution of Manipal Academy of Higher Education), Mangalore, Karnataka, India
| | - Sourjya Banerjee
- Department of Radiation Oncology, Kasturba Medical College (A Constituent Institution of Manipal Academy of Higher Education), Mangalore, Karnataka, India
| | - Challapalli Srinivas
- Department of Radiation Oncology, Kasturba Medical College (A Constituent Institution of Manipal Academy of Higher Education), Mangalore, Karnataka, India
| | - Ramamoorthy Ravichandran
- Department of Radiation Oncology, Kasturba Medical College (A Constituent Institution of Manipal Academy of Higher Education), Mangalore, Karnataka, India
| | - Suman Kumar Putha
- Department of Radiation Oncology, Kasturba Medical College (A Constituent Institution of Manipal Academy of Higher Education), Mangalore, Karnataka, India
| | - P U Prakash Saxena
- Department of Radiation Oncology, Kasturba Medical College (A Constituent Institution of Manipal Academy of Higher Education), Mangalore, Karnataka, India
| | - Shreyas Reddy
- Department of Radiation Oncology, Kasturba Medical College (A Constituent Institution of Manipal Academy of Higher Education), Mangalore, Karnataka, India
| | - Johan Sunny
- Department of Radiation Oncology, Kasturba Medical College (A Constituent Institution of Manipal Academy of Higher Education), Mangalore, Karnataka, India
| |
Collapse
|
13
|
Enhancing benefits of bolus use through minimising the effect of air-gaps on dose distribution in photon beam radiotherapy. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s1460396920000047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
AbstractIntroduction:Bolus material is frequently used on patient’s skin during radiation therapy to reduce or remove build-up effect for high-energy beams. However, the air-gaps formed between the bolus and the skin’s irregular surface reduce the accuracy of treatment planning. To achieve a good treatment outcome using bolus, experimental investigations are required to choose its thickness and to quantify the air-gap effect.Material and methods:Measurements for a 6 MV photon beam with a fixed source surface distance were carried out using the 31021 Semiflex 3D chamber into the water phantom. Firstly, the depth of maximum dose (R100) and the dose value at surface (Ds) were evaluated as a function of bolus thickness for some square fields. Secondly, to test the effect of the air-gaps ranged from 5 to 30 mm with a step of 5 mm between the bolus and the phantom surface, a water-equivalent RW3 (Goettingen White Water) slab form of 10 mm thickness was considered as a bolus.Results:We observed that the linear behaviour of R100 in terms of the bolus thickness makes the choice of this parameter more convenient depending on field size. In addition, increasing the air-gaps widens the penumbra and created electrons that have a greater probability to quit the radiation field borders before reaching the surface. The dose spread of the off-field area could have a significant influence on the patient treatment.Conclusion:Based on dose distribution comparisons between the measurements with and without air-gaps for the field size of 100 mm × 100 mm, it has been demonstrated that a maximum air-gap value lower than 5 mm would be desirable for an efficient use of the bolus technique.
Collapse
|
14
|
Wegener S, Herzog B, Sauer OA. Detector response in the buildup region of small MV fields. Med Phys 2020; 47:1327-1339. [PMID: 31860128 DOI: 10.1002/mp.13973] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 12/11/2019] [Accepted: 12/11/2019] [Indexed: 11/11/2022] Open
Abstract
PURPOSE The model used to calculate dose distributions in a radiotherapy treatment plan relies on the data entered during beam commissioning. The quality of these data heavily depends on the detector choice made, especially in small fields and in the buildup region. Therefore, it is necessary to identify suitable detectors for measurements in the buildup region of small fields. To aid the understanding of a detector's limitations, several factors that influence the detector signal are to be analyzed, for example, the volume effect due to the detector size, the response to electron contamination, the signal dependence on the polarity used, and the effective point of measurement chosen. METHODS We tested the suitability of different small field detectors for measurements of depth dose curves with a special focus on the surface-near area of dose buildup for fields sized between 10 × 10 and 0.6 × 0.6 cm2 . Depth dose curves were measured with 14 different detectors including plane-parallel chambers, thimble chambers of different types and sizes, shielded and unshielded diodes as well as a diamond detector. Those curves were compared with depth dose curves acquired on Gafchromic film. Additionally, the magnitude of geometric volume corrections was estimated from film profiles in different depths. Furthermore, a lead foil was inserted into the beam to reduce contaminating electrons and to study the resulting changes of the detector response. The role of the effective point of measurement was investigated by quantifying the changes occurring when shifting depth dose curves. Last, measurements for the small ionization chambers taken at opposing biasing voltages were compared to study polarity effects. RESULTS Depth-dependent correction factors for relative depth dose curves with different detectors were derived. Film, the Farmer chamber FC23, a 0.13 cm3 scanning chamber CC13 and a plane-parallel chamber PPC05 agree very well in fields sized 4 × 4 and 10 × 10 cm2 . For most detectors and in smaller fields, depth dose curves differ from the film. In general, shielded diodes require larger corrections than unshielded diodes. Neither the geometric volume effect nor the electron contamination can account for the detector differences. The biggest uncertainty arises from the positioning of a detector with respect to the water surface and from the choice of the detector's effective point of measurement. Depth dose curves acquired with small ionization chambers differ by over 15% in the buildup region depending on sign of the biasing voltage used. CONCLUSIONS A scanning chamber or a PPC40 chamber is suitable for fields larger than 4 × 4 cm2 . Below that field size, the microDiamond or small ionization chambers perform best requiring the smallest corrections at depth as well as in the buildup region. Diode response changes considerably between the different types of detectors. The position of the effective point of measurement has a huge effect on the resulting curves, therefore detector specific rather than general shifts of half the inner radius of cylindrical ionization chambers for the effective point of measurement should be used. For small ionization chambers, averaging between both polarities is necessary for data obtained near the surface.
Collapse
Affiliation(s)
- Sonja Wegener
- Department of Radiation Oncology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany
| | - Barbara Herzog
- Department of Radiation Oncology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany.,Institute of Physics, Martin-Luther-Universität Halle-Wittenberg, Von-Danckelmann-Platz 3, 06120, Halle (Saale), Germany
| | - Otto A Sauer
- Department of Radiation Oncology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany
| |
Collapse
|
15
|
Liuzzi R, Piccolo C, D'Avino V, Clemente S, Oliviero C, Cella L, Pugliese M. Dose-Response of TLD-100 in the Dose Range Useful for Hypofractionated Radiotherapy. Dose Response 2020; 18:1559325819894081. [PMID: 32110167 PMCID: PMC7019407 DOI: 10.1177/1559325819894081] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Revised: 11/18/2019] [Accepted: 11/19/2019] [Indexed: 02/06/2023] Open
Abstract
Purpose: The aim of the study was to exploit the feasibility of thermoluminescent
dosimeters (TLDs) in radiation therapy techniques in which high dose per
fraction is involved. Methods: Dose–response of TLD-100 (LiF: Mg, Ti) was investigated in both 6-MV photon
and 6-MeV electron beams. The element correction factor (ECF) generation
method was applied to check the variability of the TLDs response. Two
batches of 50 TLDs were divided into groups and exposed in the dose range 0
to 30 Gy. Regression analysis was performed with both linear and quadratic
models. For each irradiation beam, the calibration curves were obtained in 3
dose range 0 to 8 Gy, 0 to 10 Gy, and 0 to 30 Gy. The best-fitting model was
assessed by the Akaike Information Criterion test. Results: The ECF process resulted a useful tool to reduce the coefficients of
variation from original values higher than 5% to about 3.5%, for all the
batches exposed. The results confirm the linearity of dose–response curve
below the dose level of 10 Gy for photon and electron beam and the
supralinear trend above. Conclusion: The TLDs are suitable dosimeters for dose monitoring and verification in
radiation treatment involving dose up to 30 Gy in a single fraction.
Collapse
Affiliation(s)
- Raffaele Liuzzi
- Institute of Biostructure and Bioimaging, National Research Council (CNR), Naples, Italy
| | | | - Vittoria D'Avino
- Institute of Biostructure and Bioimaging, National Research Council (CNR), Naples, Italy.,National Institute for Nuclear Physics (INFN), Naples, Italy
| | | | | | - Laura Cella
- Institute of Biostructure and Bioimaging, National Research Council (CNR), Naples, Italy
| | - Mariagabriella Pugliese
- National Institute for Nuclear Physics (INFN), Naples, Italy.,Department of Physics "E. Pancini", Federico II University, Naples, Italy
| |
Collapse
|
16
|
Wegener S, Weick S, Sauer OA. Influence of a transverse magnetic field on the response of different detectors in a high energy photon beam near the surface. Z Med Phys 2019; 29:22-30. [DOI: 10.1016/j.zemedi.2018.07.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 05/29/2018] [Accepted: 07/02/2018] [Indexed: 10/28/2022]
|
17
|
Kesen ND, Akbas U, Koksal C, Bilge H. Investigation of AAA dose calculation algorithm accuracy in surface and buildup region for 6MV photon beam using markus parallel-plate ion chamber. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2019; 27:361-369. [PMID: 30856153 DOI: 10.3233/xst-180489] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In radiotherapy, dose distributions are obtained by using dose calculation algorithms that are implanted in treatment planning systems (TPS). This study aims to compare the surface doses of separate field sizes calculated by different version of The Analytical Anisotropic Algorithm (AAA) and measured by the parallel-plate ion chamber that is admitted as the most reliable dosimetry system for the surface region dose measurements. In order to measure the near surface dose, water equivalent solid phantom was used and measurements were made for 6MV photon beam at 100 cm source-detector distance for 5×5, 10×10, and 20×20 cm2 field sizes. AAA 8.9 and AAA 15.1 versions of the Varian Eclipse TPS were used for surface dose calculations by generating beams with separate field sizes. The doses were read by considering the effective buildup thickness of Markus parallel-plate ion chamber. The surface doses using 6 MV photon beams for 10×10 cm2 field size at 0.07 mm were found to be 11.04%, 26.25%, and 19.69% for AAA v8.9, AAA v15.1 and Markus chamber, respectively. It was seen that for both of the AAA versions and Markus parallel-plate ion chamber, increasing field sizes also increase surface dose. For all field sizes, surface dose was lowest by using AAA v8.9 at 0.07 mm. The different versions of the same TPS algorithms may calculate the surface doses distinctively. After upgrading of TPS algorithms, surface doses should be calculated and compared by measurements with different dosimetry systems to better understand their calculation behaviors in the near surface region.
Collapse
Affiliation(s)
- Nazmiye Donmez Kesen
- Division of Medical Physics, Istanbul University Oncology Institute, Istanbul, Turkey
| | - Ugur Akbas
- Division of Medical Physics, Istanbul University Oncology Institute, Istanbul, Turkey
| | - Canan Koksal
- Division of Medical Physics, Istanbul University Oncology Institute, Istanbul, Turkey
| | - Hatice Bilge
- Division of Medical Physics, Istanbul University Oncology Institute, Istanbul, Turkey
| |
Collapse
|
18
|
Monte Carlo investigation on the effect of air gap under bolus in post-mastectomy radiotherapy. Phys Med 2018; 55:82-87. [DOI: 10.1016/j.ejmp.2018.10.023] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Revised: 08/28/2018] [Accepted: 10/29/2018] [Indexed: 10/27/2022] Open
|
19
|
Total scatter factor for small fields in radiotherapy: a dosimetric comparison. JOURNAL OF RADIOTHERAPY IN PRACTICE 2018. [DOI: 10.1017/s1460396917000681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractPurposeSmall field dosimetry is complicated and accuracy in the measurement of total scatter factor (TSF) is crucial for dosimetric calculations, in making optimum intensity-modulated radiotherapy plans for treating small target volumes. In this study, we intended to determine the TSF measuring properties of CC01 and CC04 detectors for field sizes ranging from sub-centimetre to the centimetre fields.Material and methodsCC01 and CC04 chamber detectors were used to measure TSF for 6 and 18 MV photon beam delivered from the linear accelerator, through small fields in a water phantom. Small fields were created by collimator jaws and multi-leaf collimators separately, with field sizes ranging from 0·6 to 10 cm2and 0·5 to 20 cm2, respectively.ResultsCC01 measured TSF at all the given field sizes created by jaws and multi-leaf collimators for both 6 and 18 MV beams whereas CC04 could not measure TSF for field sizes <1 cm2due to volume averaging and perturbation effects.ConclusionCC01 was shown to be effective for measurement of TSF in sub-centimetre field sizes. CC01 can be employed to measure other dosimetric quantities in small fields using different energy beams.
Collapse
|
20
|
Brost EE, Watanabe Y. A mathematical deconvolution formulation for superficial dose distribution measurement by Cerenkov light dosimetry. Med Phys 2018; 45:3880-3892. [PMID: 29856473 DOI: 10.1002/mp.13021] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Revised: 05/15/2018] [Accepted: 05/15/2018] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Cerenkov photons are created by high-energy radiation beams used for radiation therapy. In this study, we developed a Cerenkov light dosimetry technique to obtain a two-dimensional dose distribution in a superficial region of medium from the images of Cerenkov photons by using a deconvolution method. METHODS An integral equation was derived to represent the Cerenkov photon image acquired by a camera for a given incident high-energy photon beam by using convolution kernels. Subsequently, an equation relating the planar dose at a depth to a Cerenkov photon image using the well-known relationship between the incident beam fluence and the dose distribution in a medium was obtained. The final equation contained a convolution kernel called the Cerenkov dose scatter function (CDSF). The CDSF function was obtained by deconvolving the Cerenkov scatter function (CSF) with the dose scatter function (DSF). The GAMOS (Geant4-based Architecture for Medicine-Oriented Simulations) Monte Carlo particle simulation software was used to obtain the CSF and DSF. The dose distribution was calculated from the Cerenkov photon intensity data using an iterative deconvolution method with the CDSF. The theoretical formulation was experimentally evaluated by using an optical phantom irradiated by high-energy photon beams. RESULTS The intensity of the deconvolved Cerenkov photon image showed linear dependence on the dose rate and the photon beam energy. The relative intensity showed a field size dependence similar to the beam output factor. Deconvolved Cerenkov images showed improvement in dose profiles compared with the raw image data. In particular, the deconvolution significantly improved the agreement in the high dose gradient region, such as in the penumbra. Deconvolution with a single iteration was found to provide the most accurate solution of the dose. Two-dimensional dose distributions of the deconvolved Cerenkov images agreed well with the reference distributions for both square fields and a multileaf collimator (MLC) defined, irregularly shaped field. CONCLUSIONS The proposed technique improved the accuracy of the Cerenkov photon dosimetry in the penumbra region. The results of this study showed initial validation of the deconvolution method for beam profile measurements in a homogeneous media. The new formulation accounted for the physical processes of Cerenkov photon transport in the medium more accurately than previously published methods.
Collapse
Affiliation(s)
- Eric Edward Brost
- Department of Radiation Oncology, University of Minnesota, 420 Delaware St. SE, MMC-494, Minneapolis, MN, USA
| | - Yoichi Watanabe
- Department of Radiation Oncology, University of Minnesota, 420 Delaware St. SE, MMC-494, Minneapolis, MN, USA
| |
Collapse
|
21
|
Comparison of surface dose delivered by 7 MV-unflattened and 6 MV-flattened photon beams. Rep Pract Oncol Radiother 2017; 22:243-250. [PMID: 28479873 DOI: 10.1016/j.rpor.2016.12.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2016] [Revised: 10/07/2016] [Accepted: 12/20/2016] [Indexed: 11/23/2022] Open
Abstract
AIM The purpose of this study is to determine the central-axis dose in the buildup region and the surface dose delivered by a 6 MV flattened photon beam (6 MV-FB) and a higher energy unflattened (7 MV-FFF) therapeutic photon beam for different-sized square fields with open fields and modifying filters. MATERIALS AND METHODS The beams are produced by a Siemens Artiste linear accelerator with a NACP-02 ionization chamber and the dose is measured by using GafChromic film and two different, commonly used, dosimeters: a p-type photon semiconductor dosimeter (PFD) and a cylindrical ionization chamber (CC13). RESULTS The results indicate that the surface dose increases linearly with FS for both open and wedged fields for the 6 MV-FB and 7 MV-FFF beams. The surface dose delivered by the 7 MV-UFB beam is consistent with that delivered by the 6 MV-FB beam for field sizes up to 10 cm × 10 cm, after which the surface dose decreases. The buildup dose for the 7 MV-UFB beam is slightly less than that for the 6 MV-FB beam for field sizes ranging from 5 cm × 5 cm to 15 cm × 15 cm. For both the 6 MV-FB and 7 MV-FFF beams, the measured surface dose clearly increases with increasing field size, regardless of the detector used in the measurement. The surface dose measured with the PFD dosimeter and the NACP-02 and CC13 chambers differ significantly from the results obtained when using GafChromic film. The 7 MV-FFF beam results in a slightly smaller surface dose in the buildup region compared with the 6 MV-FB beam. CONCLUSIONS The surface dose delivered by the higher energy 7 MV-FFF beam is less than that delivered by the energy-unmatched FFF beam in previously published works.
Collapse
|
22
|
Murai T, Kamata SE, Sato K, Miura K, Inoue M, Yokota N, Ohta S, Iwabuchi M, Iwata H, Shibamoto Y. Hypofractionated Stereotactic Radiotherapy for Auditory Canal or Middle Ear Cancer. Cancer Control 2017; 23:311-6. [PMID: 27556672 DOI: 10.1177/107327481602300315] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Stereotactic radiotherapy (SRT) may represent a new treatment option for individuals with auditory canal or middle ear cancer. METHODS Study participants with pathologically proven ear cancer were treated with SRT (35 Gy for 3 fractions or 40 Gy for 5 fractions) as first-line therapy. When local tumor recurrence developed following SRT, subtotal temporal bone resection and postoperative chemoradiotherapy were performed as salvage treatment. Boluses were used for the initial 14 study patients. RESULTS Twenty-nine study participants were enrolled and staged with T1 (n = 3), T2 (n = 7), T3 (n = 14), or T4 disease (n = 5). Three-year overall survival rates were 69% for T1/2 disease, 79% for T3 disease, and 0% for T4 disease. Three-year local control rates were 70% for T1/2 disease, 50% for T3 disease, and 20% for T4 disease. Grade 2 or higher dermatitis or soft-tissue necrosis occurred more frequently in study patients treated with boluses (8/14 vs 2/15; P = .02). Salvage treatment was safely performed for 12 recurrent cases. CONCLUSIONS These results suggest that SRT outcomes are promising for patients with ear cancer (? T3 disease). The rate of toxicity was acceptable in the study patients treated without boluses. Outcomes of salvage surgery and postoperative radiotherapy following SRT were also encouraging.
Collapse
Affiliation(s)
- Taro Murai
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya 467-8601, Japan.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Sigamani A, Nambiraj A, Yadav G, Giribabu A, Srinivasan K, Gurusamy V, Raman K, Karunakaran K, Thiyagarajan R. Surface dose measurements and comparison of unflattened and flattened photon beams. J Med Phys 2016; 41:85-91. [PMID: 27217619 PMCID: PMC4871008 DOI: 10.4103/0971-6203.181648] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The purpose of this study was to evaluate the central axis dose in the build-up region and the surface dose of a 6 MV and 10 MV flattened photon beam (FB) and flattening filter free (FFF) therapeutic photon beam for different square field sizes (FSs) for a Varian Truebeam linear accelerator using parallel-plate ionization chamber and Gafchromic film. Knowledge of dosimetric characteristics in the build-up region and surface dose of the FFF is essential for clinical care. The dose measurements were also obtained empirically using two different commonly used dosimeters: a p-type photon semiconductor dosimeter and a cylindrical ionization chamber. Surface dose increased linearly with FS for both FB and FFF photon beams. The surface dose values of FFF were higher than the FB FSs. The measured surface dose clearly increases with increasing FS. The FFF beams have a modestly higher surface dose in the build-up region than the FB. The dependence of source to skin distance (SSD) is less significant in FFF beams when compared to the flattened beams at extended SSDs.
Collapse
Affiliation(s)
- Ashokkumar Sigamani
- Division of Medical Physics, School of Advanced Sciences, VIT University, New Delhi, India
| | - Arunai Nambiraj
- Division of Medical Physics, School of Advanced Sciences, VIT University, New Delhi, India
| | - Girigesh Yadav
- Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India
| | - Ananda Giribabu
- Department of Radiation Oncology, Krishna Institute of Sciences, Hyderabad, Telangana, India
| | | | - Venkadamanickam Gurusamy
- Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India
| | - Kothanda Raman
- Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India
| | - Kaviarasu Karunakaran
- Division of Medical Physics, School of Advanced Sciences, VIT University, New Delhi, India
| | - Rajesh Thiyagarajan
- Division of Medical Physics, School of Advanced Sciences, VIT University, New Delhi, India
| |
Collapse
|
24
|
Godson HF, Ravikumar M, Sathiyan S, Ganesh KM, Ponmalar YR, Varatharaj C. Analysis of small field percent depth dose and profiles: Comparison of measurements with various detectors and effects of detector orientation with different jaw settings. J Med Phys 2016; 41:12-20. [PMID: 27051165 PMCID: PMC4795411 DOI: 10.4103/0971-6203.177284] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The advent of modern technologies in radiotherapy poses an increased challenge in the determination of dosimetric parameters of small fields that exhibit a high degree of uncertainty. Percent depth dose and beam profiles were acquired using different detectors in two different orientations. The parameters such as relative surface dose (DS), depth of dose maximum (Dmax), percentage dose at 10 cm (D10), penumbral width, flatness, and symmetry were evaluated with different detectors. The dosimetric data were acquired for fields defined by jaws alone, multileaf collimator (MLC) alone, and by MLC while the jaws were positioned at 0, 0.25, 0.5, and 1.0 cm away from MLC leaf-end using a Varian linear accelerator with 6 MV photon beam. The accuracy in the measurement of dosimetric parameters with various detectors for three different field definitions was evaluated. The relative DS(38.1%) with photon field diode in parallel orientation was higher than electron field diode (EFD) (27.9%) values for 1 cm ×1 cm field. An overestimation of 5.7% and 8.6% in D10 depth were observed for 1 cm ×1 cm field with RK ion chamber in parallel and perpendicular orientation, respectively, for the fields defined by MLC while jaw positioned at the edge of the field when compared to EFD values in parallel orientation. For this field definition, the in-plane penumbral widths obtained with ion chamber in parallel and perpendicular orientation were 3.9 mm, 5.6 mm for 1 cm ×1 cm field, respectively. Among all detectors used in the study, the unshielded diodes were found to be an appropriate choice of detector for the measurement of beam parameters in small fields.
Collapse
Affiliation(s)
- Henry Finlay Godson
- Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, Karnataka, India; Department of Radiotherapy, Christian Medical College, Vellore, Tamil Nadu, India
| | - M Ravikumar
- Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, Karnataka, India
| | - S Sathiyan
- Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, Karnataka, India
| | - K M Ganesh
- Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, Karnataka, India
| | - Y Retna Ponmalar
- Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, Karnataka, India; Department of Radiotherapy, Christian Medical College, Vellore, Tamil Nadu, India
| | - C Varatharaj
- Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, Karnataka, India
| |
Collapse
|
25
|
Characterization of a new transmission detector for patient individualized online plan verification and its influence on 6MV X-ray beam characteristics. Z Med Phys 2015; 26:200-8. [PMID: 26303190 DOI: 10.1016/j.zemedi.2015.08.001] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2015] [Revised: 08/03/2015] [Accepted: 08/03/2015] [Indexed: 11/21/2022]
Abstract
PURPOSE Online verification and 3D dose reconstruction on daily patient anatomy have the potential to improve treatment delivery, accuracy and safety. One possible implementation is to recalculate dose based on online fluence measurements with a transmission detector (TD) attached to the linac. This study provides a detailed analysis of the influence of a new TD on treatment beam characteristics. METHODS The influence of the new TD on surface dose was evaluated by measurements with an Advanced Markus Chamber (Adv-MC) in the build-up region. Based on Monte Carlo simulations, correction factors were determined to scale down the over-response of the Adv-MC close to the surface. To analyze the effects beyond dmax percentage depth dose (PDD), lateral profiles and transmission measurements were performed. All measurements were carried out for various field sizes and different SSDs. Additionally, 5 IMRT-plans (head & neck, prostate, thorax) and 2 manually created test cases (3×3cm(2) fields with different dose levels, sweeping gap) were measured to investigate the influence of the TD on clinical treatment plans. To investigate the performance of the TD, dose linearity as well as dose rate dependency measurements were performed. RESULTS With the TD inside the beam an increase in surface dose was observed depending on SSD and field size (maximum of +11%, SSD = 80cm, field size = 30×30cm(2)). Beyond dmax the influence of the TD on PDDs was below 1%. The measurements showed that the transmission factor depends slightly on the field size (0.893-0.921 for 5×5cm(2) to 30×30cm(2)). However, the evaluation of clinical IMRT-plans measured with and without the TD showed good agreement after using a single transmission factor (γ(2%/2mm) > 97%, δ±3% >95%). Furthermore, the response of TD was found to be linear and dose rate independent (maximum difference <0.5% compared to reference measurements). CONCLUSIONS When placed in the path of the beam, the TD introduced a slight, clinically acceptable increase of the skin dose even for larger field sizes and smaller SSDs and the influence of the detector on the dose beyond dmax as well as on clinical IMRT-plans was negligible. Since there was no dose rate dependency and the response was linear, the device is therefore suitable for clinical use. Only its absorption has to be compensated during treatment planning, either by the use of a single transmission factor or by including the TD in the incident beam model.
Collapse
|
26
|
Jenkins CH, Naczynski DJ, Yu SJS, Xing L. Monitoring external beam radiotherapy using real-time beam visualization. Med Phys 2015; 42:5-13. [PMID: 25563243 DOI: 10.1118/1.4901255] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To characterize the performance of a novel radiation therapy monitoring technique that utilizes a flexible scintillating film, common optical detectors, and image processing algorithms for real-time beam visualization (RT-BV). METHODS Scintillating films were formed by mixing Gd2O2S:Tb (GOS) with silicone and casting the mixture at room temperature. The films were placed in the path of therapeutic beams generated by medical linear accelerators (LINAC). The emitted light was subsequently captured using a CMOS digital camera. Image processing algorithms were used to extract the intensity, shape, and location of the radiation field at various beam energies, dose rates, and collimator locations. The measurement results were compared with known collimator settings to validate the performance of the imaging system. RESULTS The RT-BV system achieved a sufficient contrast-to-noise ratio to enable real-time monitoring of the LINAC beam at 20 fps with normal ambient lighting in the LINAC room. The RT-BV system successfully identified collimator movements with sub-millimeter resolution. CONCLUSIONS The RT-BV system is capable of localizing radiation therapy beams with sub-millimeter precision and tracking beam movement at video-rate exposure.
Collapse
Affiliation(s)
- Cesare H Jenkins
- Department of Mechanical Engineering and Department of Radiation Oncology, Stanford University, Stanford, California 94305
| | - Dominik J Naczynski
- Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305
| | - Shu-Jung S Yu
- Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305
| | - Lei Xing
- Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305
| |
Collapse
|
27
|
Sabater S, Berenguer R, Honrubia-Gomez P, Rivera M, Nuñez A, Jimenez-Jimenez E, Martos A, Ramirez-Castillejo C. How air influences radiation dose deposition in multiwell culture plates: a Monte Carlo simulation of radiation geometry. JOURNAL OF RADIATION RESEARCH 2014; 55:1009-1014. [PMID: 24722683 PMCID: PMC4202281 DOI: 10.1093/jrr/rru022] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2013] [Revised: 02/12/2014] [Accepted: 03/02/2014] [Indexed: 06/03/2023]
Abstract
Radiation of experimental culture cells on plates with various wells can cause a risk of underdosage as a result of the existence of multiple air-water interfaces. The objective of our study was to quantify this error in culture plates with multiple wells. Radiation conditions were simulated with the GAMOS code, based on the GEANT4 code, and this was compared with a simulation performed with PENELOPE and measured data. We observed a slight underdosage of ∼ 4% on the most superficial half of the culture medium. We believe that this underdosage does not have a significant effect on the dose received by culture cells deposited in a monolayer and adhered to the base of the wells.
Collapse
Affiliation(s)
- Sebastia Sabater
- Department of Radiation Oncology, Complejo Hospitalario Universitario de Albacete (CHUA), C/ Hnos Falcó 37, 02006 Albacete, Spain
| | - Roberto Berenguer
- Department of Medical Physics, Complejo Hospitalario Universitario de Albacete (CHUA), C/ Hnos Falcó 37, 02006 Albacete, Spain
| | - Paloma Honrubia-Gomez
- Centro Regional de Investigaciones Biomedicas (CRIB), Universidad de Castilla-la Mancha (UM), C/ Almansa 14, 02006 Albacete, Spain
| | - Miguel Rivera
- Department of Medical Physics, Complejo Hospitalario Universitario de Albacete (CHUA), C/ Hnos Falcó 37, 02006 Albacete, Spain
| | - Ana Nuñez
- Department of Medical Physics, Complejo Hospitalario Universitario de Albacete (CHUA), C/ Hnos Falcó 37, 02006 Albacete, Spain
| | - Esther Jimenez-Jimenez
- Department of Radiation Oncology, Hospital Son Espases, Carretera de Valldemossa 79, 07120 Palma de Mallorca, Spain
| | - Ana Martos
- Department of Radiation Oncology, Complejo Hospitalario Universitario de Albacete (CHUA), C/ Hnos Falcó 37, 02006 Albacete, Spain
| | - Carmen Ramirez-Castillejo
- Centro Regional de Investigaciones Biomedicas (CRIB), Universidad de Castilla-la Mancha (UM), C/ Almansa 14, 02006 Albacete, Spain Instituto de Salud Carlos III. Av Monforte de Lemos 5, 28029 Madrid, Spain
| |
Collapse
|
28
|
A comparison of surface doses for very small field size x-ray beams: Monte Carlo calculations and radiochromic film measurements. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2014; 37:303-9. [DOI: 10.1007/s13246-014-0260-2] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2013] [Accepted: 03/04/2014] [Indexed: 12/15/2022]
|
29
|
Zhang R, Fox CJ, Glaser AK, Gladstone DJ, Pogue BW. Superficial dosimetry imaging of Čerenkov emission in electron beam radiotherapy of phantoms. Phys Med Biol 2013; 58:5477-93. [PMID: 23880473 DOI: 10.1088/0031-9155/58/16/5477] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Čerenkov emission is generated from ionizing radiation in tissue above 264 keV energy. This study presents the first examination of this optical emission as a surrogate for the absorbed superficial dose. Čerenkov emission was imaged from the surface of flat tissue phantoms irradiated with electrons, using a range of field sizes from 6 cm × 6 cm to 20 cm × 20 cm, incident angles from 0° to 50°, and energies from 6 to 18 MeV. The Čerenkov images were compared with the estimated superficial dose in phantoms from direct diode measurements, as well as calculations by Monte Carlo and the treatment planning system. Intensity images showed outstanding linear agreement (R(2) = 0.97) with reference data of the known dose for energies from 6 to 18 MeV. When orthogonal delivery was carried out, the in-plane and cross-plane dose distribution comparisons indicated very little difference (± 2-4% differences) between the different methods of estimation as compared to Čerenkov light imaging. For an incident angle 50°, the Čerenkov images and Monte Carlo simulation show excellent agreement with the diode data, but the treatment planning system had a larger error (OPT = ± 1~2%, diode = ± 2~3%, TPS = ± 6-8% differences) as would be expected. The sampling depth of superficial dosimetry based on Čerenkov radiation has been simulated in a layered skin model, showing the potential of sampling depth tuning by spectral filtering. Taken together, these measurements and simulations indicate that Čerenkov emission imaging might provide a valuable method of superficial dosimetry imaging from incident radiotherapy beams of electrons.
Collapse
Affiliation(s)
- Rongxiao Zhang
- Department of Physics and Astronomy, Dartmouth College, Hanover, NH 03755, USA. Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA.
| | | | | | | | | |
Collapse
|
30
|
Fricker K, Thompson C, Meyer J. Assessment of concomitant testicular dose with radiochromic film. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2013; 36:269-77. [PMID: 23794085 DOI: 10.1007/s13246-013-0208-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2013] [Accepted: 06/17/2013] [Indexed: 12/26/2022]
Abstract
To assess the suitability of EBT2 and XRQA2 Gafchromic film for measuring low doses in the periphery of treatment fields, and to measure the accumulative concomitant dose to the contralateral testis resulting from CT imaging, pre-treatment imaging (CBCT) and seminoma radiotherapy with and without gonadal shielding. Superficial peripheral dose measurements made using EBT2 Gafchromic film on the surface of water equivalent material were compared to measurements made with an ionisation chamber in a water phantom to evaluate the suitability and accuracy of the film dosimeter for such measurements. Similarly, XRQA2 was used to measure surface doses within a kilovoltage beam and compared with ionisation chamber measurements. Gafchromic film was used to measure CT, CBCT and seminoma treatment related testicular doses on an anthropomorphic phantom. Doses were assessed for two clinical plans, both with and without gonadal shielding. Testicular doses resulting from the treatment of up to 0.83 ± 0.17 Gy were measured per treatment. Additional doses of up to 0.49 ± 0.01 and 2.35 ± 0.05 cGy were measured per CBCT and CT image, respectively. Reductions in the testicular dose in the order of 10, 36 and 78% were observed when gonadal shielding was fitted for treatment, CT and CBCT imaging, respectively. Gafchromic film was found to be suitable for measuring dose in the periphery of treatment fields. The dose to the testis should be limited to minimise the risk of radiation related side effects. This can be achieved by using appropriate gonadal shielding, irrespective of the treatment fields employed.
Collapse
Affiliation(s)
- Katherine Fricker
- Department of Physics and Astronomy, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand.
| | | | | |
Collapse
|