1
|
Gabriela R, Vera V, Pavel R, Helena R, Igor S, Marie D, Marketa M, Alena MF, Ales T. Discovering the Radiation Biomarkers in the Plasma of Total-Body Irradiated Leukemia Patients. Radiat Res 2024; 201:418-428. [PMID: 38315067 DOI: 10.1667/rade-23-00137.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 12/12/2023] [Indexed: 02/07/2024]
Abstract
The increased risk of acute large-scale radiological exposure for the world's population underlines the need for optimal radiation biomarkers. Ionizing radiation triggers a complex response by the genome, proteome, and metabolome, all of which have been reported as suitable indicators of radiation-induced damage in vivo. This study analyzed peripheral blood samples from total-body irradiation (TBI) leukemia patients through mass spectrometry (MS) to identify and quantify differentially regulated proteins in plasma before and after irradiation. In brief, samples were taken from 16 leukemic patients prior to and 24 h after TBI (2 × 2.0 Gy), processed with Tandem Mass Tag isobaric labelling kit (TMTpro-16-plex), and analyzed by MS. In parallel, label-free relative quantification was performed with a RP-nanoLC-ESI-MS/MS system in a Q-Exactive mass spectrometer. Protein identification was done in Proteome Discoverer v.2.2 platform (Thermo). Data is available via ProteomeXchange with identifier PXD043516. Using two different methods, we acquired two datasets of up-regulated (ratio ≥ 1.2) or down-regulated (ratio ≤ 0.83) plasmatic proteins 24 h after irradiation, identifying 356 and 346 proteins in the TMT-16plex and 285 and 308 label-free analyses, respectively (P ≤ 0.05). Combining the two datasets yielded 15 candidates with significant relation to gamma-radiation exposure. The majority of these proteins were associated with the inflammatory response and lipid metabolism. Subsequently, from these, five proteins showed the strongest potential as radiation biomarkers in humans (C-reactive protein, Alpha amylase 1A, Mannose-binding protein C, Phospholipid transfer protein, and Complement C5). These candidate biomarkers might have implications for practical biological dosimetry.
Collapse
Affiliation(s)
- Rydlova Gabriela
- Department of Radiobiology
- Department of Biology, Faculty of Natural Sciences, University of Hradec Králové, Czech Republic, Hradec Králové, Czech Republic
| | | | | | - Rehulkova Helena
- Department of Toxicology, Faculty of Military Health Sciences, University of Defence, Hradec Králové, Czech Republic
| | - Sirak Igor
- Department of Oncology and Radiotherapy and 4th Department of Internal Medicine - Haematology, University Hospital, Hradec Kralove, Czech Republic
| | - Davidkova Marie
- Department of Radiation Dosimetry, Nuclear Physics Institute of the Czech Academy of Sciences, Prague, Czech Republic
| | - Markova Marketa
- Department of Haematology and Blood Transfusion, University Hospital Na Bulovce, Prague, Czech Republic
| | - Myslivcova-Fucikova Alena
- Department of Biology, Faculty of Natural Sciences, University of Hradec Králové, Czech Republic, Hradec Králové, Czech Republic
| | | |
Collapse
|
2
|
Inman JL, Wu Y, Chen L, Brydon E, Ghosh D, Wan KH, De Chant J, Obst-Huebl L, Nakamura K, Ralston CY, Celniker SE, Mao JH, Zwart PH, Holman HYN, Chang H, Brown JB, Snijders AM. Long-term, non-invasive FTIR detection of low-dose ionizing radiation exposure. Sci Rep 2024; 14:6119. [PMID: 38480827 PMCID: PMC10937999 DOI: 10.1038/s41598-024-56491-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 03/07/2024] [Indexed: 03/17/2024] Open
Abstract
Non-invasive methods of detecting radiation exposure show promise to improve upon current approaches to biological dosimetry in ease, speed, and accuracy. Here we developed a pipeline that employs Fourier transform infrared (FTIR) spectroscopy in the mid-infrared spectrum to identify a signature of low dose ionizing radiation exposure in mouse ear pinnae over time. Mice exposed to 0.1 to 2 Gy total body irradiation were repeatedly measured by FTIR at the stratum corneum of the ear pinnae. We found significant discriminative power for all doses and time-points out to 90 days after exposure. Classification accuracy was maximized when testing 14 days after exposure (specificity > 0.9 with a sensitivity threshold of 0.9) and dropped by roughly 30% sensitivity at 90 days. Infrared frequencies point towards biological changes in DNA conformation, lipid oxidation and accumulation and shifts in protein secondary structure. Since only hundreds of samples were used to learn the highly discriminative signature, developing human-relevant diagnostic capabilities is likely feasible and this non-invasive procedure points toward rapid, non-invasive, and reagent-free biodosimetry applications at population scales.
Collapse
Affiliation(s)
- Jamie L Inman
- Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
| | - Yulun Wu
- Environmental Genomics and Systems Biology Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
- Department of Statistics, University of California, Berkeley, CA, 94720, USA
| | - Liang Chen
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
| | - Ella Brydon
- Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
| | - Dhruba Ghosh
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
- Paul G. Allen School of Computer Science and Engineering, University of Washington, Seattle, USA
| | - Kenneth H Wan
- Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
| | - Jared De Chant
- Accelerator Technology and Applied Physics Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
| | - Lieselotte Obst-Huebl
- Accelerator Technology and Applied Physics Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
| | - Kei Nakamura
- Accelerator Technology and Applied Physics Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
| | - Corie Y Ralston
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
| | - Susan E Celniker
- Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
| | - Jian-Hua Mao
- Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
| | - Peter H Zwart
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA
| | - Hoi-Ying N Holman
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA.
| | - Hang Chang
- Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA.
| | - James B Brown
- Environmental Genomics and Systems Biology Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA.
- Department of Statistics, University of California, Berkeley, CA, 94720, USA.
| | - Antoine M Snijders
- Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA, 94720, USA.
| |
Collapse
|
3
|
Kim K, Kim KS, Jang WI, Jang S, Hwang GT, Woo SK. Deep Neural Network-Based Automatic Dicentric Chromosome Detection Using a Model Pretrained on Common Objects. Diagnostics (Basel) 2023; 13:3191. [PMID: 37892012 PMCID: PMC10606160 DOI: 10.3390/diagnostics13203191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 10/06/2023] [Accepted: 10/09/2023] [Indexed: 10/29/2023] Open
Abstract
Dicentric chromosome assay (DCA) is one of the cytogenetic dosimetry methods where the absorbed dose is estimated by counting the number of dicentric chromosomes, which is a major radiation-induced change in DNA. However, DCA is a time-consuming task and requires technical expertise. In this study, a neural network was applied for automating the DCA. We used YOLOv5, a one-stage detection algorithm, to mitigate these limitations by automating the estimation of the number of dicentric chromosomes in chromosome metaphase images. YOLOv5 was pretrained on common object datasets. For training, 887 augmented chromosome images were used. We evaluated the model using validation and test datasets with 380 and 300 images, respectively. With pretrained parameters, the trained model detected chromosomes in the images with a maximum F1 score of 0.94 and a mean average precision (mAP) of 0.961. Conversely, when the model was randomly initialized, the training performance decreased, with a maximum F1 score and mAP of 0.82 and 0.873%, respectively. These results confirm that the model could effectively detect dicentric chromosomes in an image. Consequently, automatic DCA is expected to be conducted based on deep learning for object detection, requiring a relatively small amount of chromosome data for training using the pretrained network.
Collapse
Affiliation(s)
- Kangsan Kim
- Division of Applied RI, Korea Institute of Radiological and Medical Sciences, Seoul 01812, Republic of Korea;
| | - Kwang Seok Kim
- Department of Radiation Oncology, Korea Institute of Radiological and Medical Sciences, Seoul 01812, Republic of Korea
| | - Won Il Jang
- Department of Radiation Oncology, Korea Institute of Radiological and Medical Sciences, Seoul 01812, Republic of Korea
| | - Seongjae Jang
- National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul 01812, Republic of Korea;
| | - Gil Tae Hwang
- Department of Chemistry and Green-Nano Materials Research Center, Kyungpook National University, Daegu 41566, Republic of Korea;
| | - Sang-Keun Woo
- Division of Applied RI, Korea Institute of Radiological and Medical Sciences, Seoul 01812, Republic of Korea;
| |
Collapse
|
4
|
Choi YY, Kim A, Lee Y, Lee YH, Park M, Shin E, Park S, Youn B, Seong KM. The miR-126-5p and miR-212-3p in the extracellular vesicles activate monocytes in the early stage of radiation-induced vascular inflammation implicated in atherosclerosis. J Extracell Vesicles 2023; 12:e12325. [PMID: 37140946 PMCID: PMC10158827 DOI: 10.1002/jev2.12325] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 04/04/2023] [Accepted: 04/12/2023] [Indexed: 05/05/2023] Open
Abstract
People exposed to radiation in cancer therapy and nuclear accidents are at increased risk of cardiovascular outcomes in long-term survivors. Extracellular vesicles (EVs) are involved in radiation-induced endothelial dysfunction, but their role in the early stage of vascular inflammation after radiation exposure remains to be fully understood. Herein, we demonstrate that endothelial cell-derived EVs containing miRNAs initiate monocyte activation in radiation-induced vascular inflammation. In vitro co-culture and in vivo experimental data showed that endothelial EVs can be sensitively increased by radiation exposure in a dose-dependent manner, and stimulate monocytes releasing monocytic EVs and adhesion to endothelial cells together with an increase in the expression of genes encoding specific ligands for cell-cell interaction. Small RNA sequencing and transfection using mimics and inhibitors explained that miR-126-5p and miR-212-3p enriched in endothelial EVs initiate vascular inflammation by monocyte activation after radiation exposure. Moreover, miR-126-5p could be detected in the circulating endothelial EVs of radiation-induced atherosclerosis model mice, which was found to be tightly correlated with the atherogenic index of plasma. In summary, our study showed that miR-126-5p and miR-212-3p present in the endothelial EVs mediate the inflammatory signals to activate monocytes in radiation-induced vascular injury. A better understanding of the circulating endothelial EVs content can promote their use as diagnostic and prognostic biomarkers for atherosclerosis after radiation exposure.
Collapse
Affiliation(s)
- You Yeon Choi
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - Areumnuri Kim
- Laboratory of Radiation Exposure and Therapeutics, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - Younghyun Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - Yang Hee Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - Mineon Park
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - Eunguk Shin
- Department of Biological Sciences, Pusan National University, Busan, Republic of Korea
| | - Sunhoo Park
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - BuHyun Youn
- Department of Biological Sciences, Pusan National University, Busan, Republic of Korea
| | - Ki Moon Seong
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| |
Collapse
|
5
|
Dicentric chromosome assay using a deep learning-based automated system. Sci Rep 2022; 12:22097. [PMID: 36543843 PMCID: PMC9772420 DOI: 10.1038/s41598-022-25856-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Accepted: 12/06/2022] [Indexed: 12/24/2022] Open
Abstract
The dicentric chromosome assay is the "gold standard" in biodosimetry for estimating radiation exposure. However, its large-scale deployment is limited owing to its time-consuming nature and requirement for expert reviewers. Therefore, a recently developed automated system was evaluated for the dicentric chromosome assay. A previously constructed deep learning-based automatic dose-estimation system (DLADES) was used to construct dose curves and calculate estimated doses. Blood samples from two donors were exposed to cobalt-60 gamma rays (0-4 Gy, 0.8 Gy/min). The DLADES efficiently identified monocentric and dicentric chromosomes but showed impaired recognition of complete cells with 46 chromosomes. We estimated the chromosome number of each "Accepted" sample in the DLADES and sorted similar-quality images by removing outliers using the 1.5IQR method. Eleven of the 12 data points followed Poisson distribution. Blind samples were prepared for each dose to verify the accuracy of the estimated dose generated by the curve. The estimated dose was calculated using Merkle's method. The actual dose for each sample was within the 95% confidence limits of the estimated dose. Sorting similar-quality images using chromosome numbers is crucial for the automated dicentric chromosome assay. We successfully constructed a dose-response curve and determined the estimated dose using the DLADES.
Collapse
|
6
|
Takebayashi K, Echizenya K, Kameya Y, Nakajima D, Nakayama R, Fujishima Y, Goh VST, Abe Y, Kasai K, Anderson DA, Blakely WF, Miura T. Mitotic index maximization with no effect on radiation-induced dicentric chromosome frequency. Int J Radiat Biol 2022; 99:750-759. [PMID: 36318780 DOI: 10.1080/09553002.2023.2142981] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
PURPOSE The dicentric chromosome (Dic) assay, which is the gold standard for biological dose assessment in radiation emergency medicine, requires an analysis of at least 500 lymphocyte metaphases or 100 Dic aberrations. Therefore, peripheral blood culture conditions able to obtain a high frequency of metaphases for efficient dose evaluation should be optimized. However, the type of blood cultures [i.e. whole blood (WB) or isolated peripheral blood mononuclear cell (PBMC)-culture] and blood volume differ between biodosimetry laboratories. The purpose of this study is to investigate the blood volume at which a high mitotic index (MI) is obtained in peripheral WB-culture and isolated PBMC-culture, and to examine the possible effect of blood volume on radiation-induced Dic frequency. MATERIALS AND METHODS Peripheral blood was collected from three healthy donors with their informed consent. The complete and differential blood counts were performed using an automated hematology analyzer. After blood count, peripheral blood was irradiated with 0 or 2 Gy X-ray. Blood was cultured with phytohemagglutinin (180 μg/ml) and demecolcine (0.05 μg/ml) for 48 h. The MI and Dic frequency were analyzed in 5, 10, 15, 20, 25, and 30% WB-cultures and 0.6, 1.2, 1.8, 2.4, 3.0, 3.6, and 4.2 ml WB-equivalent PBMC-cultures. RESULTS In WB-culture, MI showed the highest value (∼22%) in 5-15% WB-culture and then gradually decreased to ∼9% with 30% WB-culture. MI peaked at 36 and 31% in 1.8 and 2.4 ml-WB equivalent volumes for PMBC-cultures, respectively. MI progressively decreased as the amount of PBMCs increased. Although individual differences were observed in the MI values among the three subjects, all the subjects showed the same tendency and higher MI was seen in PBMC than WB-cultures. However, these factors had no significant impact on the yield of Dics. In all culture conditions, the estimated dose calculated based on the Dic frequency was equivalent to the absorbed dose of ex vivo X-ray-irradiated blood. CONCLUSION While MI was affected by the blood culture type and the volume of cultured blood, Dic yield did not differ significantly between these conditions. These results could be used by relevant laboratories to optimize MI in certain circumstances.
Collapse
Affiliation(s)
- Kai Takebayashi
- Department of Risk Analysis and Biodosimetry, Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Japan
- Department of Bioscience and Laboratory Medicine, Hirosaki University Graduate School of Health Sciences, Hirosaki, Japan
| | - Keito Echizenya
- Department of Risk Analysis and Biodosimetry, Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Japan
| | - Yuki Kameya
- Department of Risk Analysis and Biodosimetry, Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Japan
| | - Daichi Nakajima
- Department of Risk Analysis and Biodosimetry, Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Japan
| | - Ryo Nakayama
- Department of Risk Analysis and Biodosimetry, Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Japan
- Department of Bioscience and Laboratory Medicine, Hirosaki University Graduate School of Health Sciences, Hirosaki, Japan
| | - Yohei Fujishima
- Department of Risk Analysis and Biodosimetry, Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Japan
| | - Valerie Swee Ting Goh
- Department of Radiobiology, Singapore Nuclear Research and Safety Initiative, National University of Singapore, Singapore
| | - Yu Abe
- Department of Radiation Biology and Protection, Atomic Bomb Disease Institute, Nagasaki University, Nagasaki, Japan
| | - Kosuke Kasai
- Department of Bioscience and Laboratory Medicine, Hirosaki University Graduate School of Health Sciences, Hirosaki, Japan
| | - Donovan A. Anderson
- Department of Risk Analysis and Biodosimetry, Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Japan
| | - William F. Blakely
- Scientific Research Department, Armed Forces Radiobiology Research Institute (AFRRI), Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| | - Tomisato Miura
- Department of Risk Analysis and Biodosimetry, Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Japan
| |
Collapse
|
7
|
Lee Y, Kim SH, Lee YH, Yang SS, Yoon HJ, Wilkins RC, Jang S. Application of a semi-automated dicentric scoring system in triage and monitoring occupational radiation exposure. Front Public Health 2022; 10:1002501. [PMID: 36339161 PMCID: PMC9631783 DOI: 10.3389/fpubh.2022.1002501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 10/06/2022] [Indexed: 01/27/2023] Open
Abstract
The dicentric chromosome assay (DCA) is considered the gold standard for radiation biodosimetry, but it is limited by its long dicentric scoring time and need for skilled scorers. The automation of scoring dicentrics has been considered a strategy to overcome the constraints of DCA. However, the studies on automated scoring methods are limited compared to those on conventional manual DCA. Our study aims to assess the performance of a semi-automated scoring method for DCA using ex vivo and in vivo irradiated samples. Dose estimations of 39 blind samples irradiated ex vivo and 35 industrial radiographers occupationally exposed in vivo were estimated using the manual and semi-automated scoring methods and subsequently compared. The semi-automated scoring method, which removed the false positives of automated scoring using the dicentric chromosome (DC) scoring algorithm, had an accuracy of 94.9% in the ex vivo irradiated samples. It also had more than 90% accuracy, sensitivity, and specificity to distinguish binary dose categories reflecting clinical, diagnostic, and epidemiological significance. These data were comparable to those of manual DCA. Moreover, Cohen's kappa statistic and McNemar's test showed a substantial agreement between the two methods for categorizing in vivo samples into never and ever radiation exposure. There was also a significant correlation between the two methods. Despite of comparable results with two methods, lower sensitivity of semi-automated scoring method could be limited to assess various radiation exposures. Taken together, our findings show the semi-automated scoring method can provide accurate dose estimation rapidly, and can be useful as an alternative to manual DCA for biodosimetry in large-scale accidents or cases to monitor radiation exposure of radiation workers.
Collapse
Affiliation(s)
- Younghyun Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea,Department of Biomedical Laboratory Science, College of Medical Sciences, Soonchunhyang University, Asan, South Korea
| | - Seung Hyun Kim
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Yang Hee Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Su San Yang
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Hyo Jin Yoon
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Ruth C. Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, ON, Canada
| | - Seongjae Jang
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea,*Correspondence: Seongjae Jang
| |
Collapse
|
8
|
Identification of Radiation-Induced miRNA Biomarkers Using the CGL1 Cell Model System. Bioengineering (Basel) 2022; 9:bioengineering9050214. [PMID: 35621492 PMCID: PMC9137836 DOI: 10.3390/bioengineering9050214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 05/11/2022] [Accepted: 05/14/2022] [Indexed: 11/17/2022] Open
Abstract
MicroRNAs (miRNAs) have emerged as a potential class of biomolecules for diagnostic biomarker applications. miRNAs are small non-coding RNA molecules, produced and released by cells in response to various stimuli, that demonstrate remarkable stability in a wide range of biological fluids, in extreme pH fluctuations, and after multiple freeze–thaw cycles. Given these advantages, identification of miRNA-based biomarkers for radiation exposures can contribute to the development of reliable biological dosimetry methods, especially for low-dose radiation (LDR) exposures. In this study, an miRNAome next-generation sequencing (NGS) approach was utilized to identify novel radiation-induced miRNA gene changes within the CGL1 human cell line. Here, irradiations of 10, 100, and 1000 mGy were performed and the samples were collected 1, 6, and 24 h post-irradiation. Corroboration of the miRNAome results with RT-qPCR verification confirmed the identification of numerous radiation-induced miRNA expression changes at all doses assessed. Further evaluation of select radiation-induced miRNAs, including miR-1228-3p and miR-758-5p, as well as their downstream mRNA targets, Ube2d2, Ppp2r2d, and Id2, demonstrated significantly dysregulated reciprocal expression patterns. Further evaluation is needed to determine whether the candidate miRNA biomarkers identified in this study can serve as suitable targets for radiation biodosimetry applications.
Collapse
|
9
|
Nersesyan A, Kundi M, Fenech M, Stopper H, da Silva J, Bolognesi C, Mišík M, Knasmueller S. Recommendations and quality criteria for micronucleus studies with humans. MUTATION RESEARCH. REVIEWS IN MUTATION RESEARCH 2022; 789:108410. [PMID: 35690413 DOI: 10.1016/j.mrrev.2021.108410] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 12/15/2021] [Accepted: 12/17/2021] [Indexed: 06/15/2023]
Abstract
Micronucleus (MN) analyses in peripheral blood lymphocytes and exfoliated cells from different organs (mouth, nose, bladder and cervix) are at present the most widely used approaches to detect damage of genetic material in humans. MN are extranuclear DNA-containing bodies, which can be identified microscopically. They reflect structural and numerical chromosomal aberrations and are formed as a consequence of exposure to occupational, environmental and lifestyle genotoxins. They are also induced as a consequence of inadequate intake of certain trace elements and vitamins. High MN rates are associated with increased risk of cancer and a range of non-cancer diseases in humans. Furthermore, evidence is accumulating that measurements of MN could be a useful tool for the diagnosis and prognosis of different forms of cancer and other diseases (inflammation, infections, metabolic disorders) and for the assessment of the therapeutic success of medical treatments. Recent reviews of the current state of knowledge suggest that many clinical studies have methodological shortcomings. This could lead to controversial findings and limits their usefulness in defining the impact of exposure concentrations of hazardous chemicals, for the judgment of remediation strategies, for the diagnosis of diseases and for the identification of protective or harmful dietary constituents. This article describes important quality criteria for human MN studies and contains recommendations for acceptable study designs. Important parameters that need more attention include sufficiently large group sizes, adequate duration of intervention studies, the exclusion of confounding factors which may affect the results (sex, age, body mass index, nutrition, etc.), the evaluation of appropriate cell numbers per sample according to established scoring criteria as well as the use of proper stains and adequate statistical analyses.
Collapse
Affiliation(s)
- A Nersesyan
- Institute of Cancer Research, Department of Medicine I, Medical University of Vienna, Vienna, Austria
| | - M Kundi
- Center for Public Health, Department of Environmental Health, Medical University of Vienna, Vienna, Austria
| | - M Fenech
- School of Pharmacy and Medical Sciences, University of South Australia, Adelaide, Australia; Universiti Kebangsaan Malaysia, Selangor, Malaysia; Genome Health Foundation, North Brighton, SA, Australia
| | - H Stopper
- Institute of Pharmacology and Toxicology, Wuerzburg University, Wuerzburg, Germany
| | - J da Silva
- Laboratory of Genetic Toxicology, Lutheran University of Brazil (ULBRA) & LaSalle University (UniLaSalle), Canoas, RS, Brazil
| | - C Bolognesi
- Environmental Carcinogenesis Unit, Ospedale Policlinico San Martino, Genoa, Italy
| | - M Mišík
- Institute of Cancer Research, Department of Medicine I, Medical University of Vienna, Vienna, Austria
| | - S Knasmueller
- Institute of Cancer Research, Department of Medicine I, Medical University of Vienna, Vienna, Austria.
| |
Collapse
|
10
|
Gnanasekaran TS. Cytogenetic biological dosimetry assays: recent developments and updates. Radiat Oncol J 2021; 39:159-166. [PMID: 34610654 PMCID: PMC8497872 DOI: 10.3857/roj.2021.00339] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Accepted: 04/21/2021] [Indexed: 12/03/2022] Open
Abstract
Biological dosimetry is the measurement of radiation-induced changes in the human to measure short and long-term health risks. Biodosimetry offers an independent means of obtaining dose information and also provides diagnostic information on the potential for “partial-body” exposure information using biological indicators and otherwise based on computer modeling, dose reconstruction, and physical dosimetry. A variety of biodosimetry tools are available and some features make some more valuable than others. Among the available biodosimetry tool, cytogenetic biodosimetry methods occupy an exclusive and advantageous position. The cytogenetic analysis can complement physical dosimetry by confirming or ruling out an accidental radiological exposure or overexposures. We are discussing the recent developments and adaptability of currently available cytogenetic biological dosimetry assays.
Collapse
|
11
|
Lin WC, Chang KW, Liao TZ, Ou Yang FY, Chang TJ, Yuan MC, Wilkins RC, Chang CH. Intercomparison of conventional and QuickScan dicentric scoring for the validation of individual biodosimetry analysis in Taiwan. Int J Radiat Biol 2021; 97:916-925. [PMID: 34003708 DOI: 10.1080/09553002.2021.1928789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 04/12/2021] [Accepted: 04/20/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE The dicentric chromosome assay (DCA), the gold standard for radiation biodosimetry, evaluates an individual absorbed radiation dose by the analysis of DNA damage in human lymphocytes. The conventional (C-DCA) and QuickScan (QS-DCA) scoring methods are sensitive for estimating radiation dose. The Biodosimetry Laboratory at Institute of Nuclear Energy Research (INER), Taiwan, participated in intercomparison exercises conducted by Health Canada (HC) in 2014, 2015 and 2018 to validate the laboratory's accuracy and performance. MATERIAL AND METHODS Blood samples for the conventional dose response curve for Taiwan were irradiated with 0, 0.25, 0.5, 1, 2, 3, 4 and 5 Gy. Ten blind blood samples were provided by HC. Either or both of two methods of conventional (C) or QuickScan (QS) scoring could be chosen for the HC's intercomparison. For C-DCA triage scoring, only cells with 46 centromeres were counted and each scorer recorded the number of dicentrics in the first 50 metaphases or stopped scoring when 30 dicentrics were reached. Scorers also recorded how much time it took to analyze 10, 20, and 50 cells. Subsequently, the data were entered into the Dose Estimate software (DoseEstimate_v5.1) and dose estimates were calculated. With QS-DCA scoring, a minimum of 50 metaphase cells (or 30 dicentrics) were scored in apparently complete metaphases without verification of exactly 46 centromeres. RESULTS For the blinded blood samples irradiated at HC and shipped to INER, the mean absolute deviation (MAD) derived after scoring 50 cells for C-DCA and QS-DCA was <0.5 Gy for all three intercomparisons, meeting the criteria for acceptance. CONCLUSION The results indicated that the Biodosimetry Laboratory at INER can provide reliable dose estimates in the case of a large-scale radiation accident.
Collapse
Affiliation(s)
- Wan-Chi Lin
- Isotope Application Division, Institute of Nuclear Energy Research, Taoyuan, Taiwan
| | - Kang-Wei Chang
- Laboratory Animal Center, Taipei Medical University, Taipei, Taiwan
- Neuroscience Research Center, Taipei Medical University, Taipei, Taiwan
| | - Tse-Zung Liao
- Isotope Application Division, Institute of Nuclear Energy Research, Taoyuan, Taiwan
| | - Fang-Yu Ou Yang
- Isotope Application Division, Institute of Nuclear Energy Research, Taoyuan, Taiwan
| | - Tsui-Jung Chang
- Health Physics Division, Institute of Nuclear Energy Research, Taoyuan, Taiwan
| | - Ming-Chen Yuan
- Health Physics Division, Institute of Nuclear Energy Research, Taoyuan, Taiwan
| | - Ruth C Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, Canada
| | - Chih-Hsien Chang
- Isotope Application Division, Institute of Nuclear Energy Research, Taoyuan, Taiwan
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan
| |
Collapse
|
12
|
Jang S, Shin SG, Lee MJ, Han S, Choi CH, Kim S, Cho WS, Kim SH, Kang YR, Jo W, Jeong S, Oh S. Feasibility Study on Automatic Interpretation of Radiation Dose Using Deep Learning Technique for Dicentric Chromosome Assay. Radiat Res 2021; 195:163-172. [PMID: 33316052 DOI: 10.1667/rade-20-00167.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Accepted: 10/26/2020] [Indexed: 11/03/2022]
Abstract
The interpretation of radiation dose is an important procedure for both radiological operators and persons who are exposed to background or artificial radiations. Dicentric chromosome assay (DCA) is one of the representative methods of dose estimation that discriminates the aberration in chromosomes modified by radiation. Despite the DCA-based automated radiation dose estimation methods proposed in previous studies, there are still limitations to the accuracy of dose estimation. In this study, a DCA-based automated dose estimation system using deep learning methods is proposed. The system is comprised of three stages. In the first stage, a classifier based on a deep learning technique is used for filtering the chromosome images that are not appropriate for use in distinguishing the chromosome; 99% filtering accuracy was achieved with 2,040 test images. In the second stage, the dicentric rate is evaluated by counting and identifying chromosomes based on the Feature Pyramid Network, which is one of the object detection algorithms based on deep learning architecture. The accuracies of the neural networks for counting and identifying chromosomes were estimated at over 97% and 90%, respectively. In the third stage, dose estimation is conducted using the dicentric rate and the dose-response curve. The accuracies of the system were estimated using two independent samples; absorbed doses ranging from 1- 4 Gy agreed well within a 99% confidential interval showing highest accuracy compared to those in previous studies. The goal of this study was to provide insights towards achieving complete automation of the radiation dose estimation, especially in the event of a large-scale radiation exposure incident.
Collapse
Affiliation(s)
- Seungsoo Jang
- Division of Advanced Nuclear Engineering, POSTECH, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Korea
| | - Sung-Gyun Shin
- Division of Advanced Nuclear Engineering, POSTECH, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Korea
| | - Min-Jae Lee
- Division of Advanced Nuclear Engineering, POSTECH, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Korea
| | - Sangsoo Han
- Division of Advanced Nuclear Engineering, POSTECH, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Korea.,SierraBASE Co. Ltd., 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Korea
| | - Chan-Ho Choi
- Division of Advanced Nuclear Engineering, POSTECH, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Korea
| | - Sungkyum Kim
- Division of Advanced Nuclear Engineering, POSTECH, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Korea
| | - Woo-Sung Cho
- Division of Advanced Nuclear Engineering, POSTECH, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Korea
| | - Song-Hyun Kim
- Division of Advanced Nuclear Engineering, POSTECH, 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Korea.,SierraBASE Co. Ltd., 77 Cheongam-Ro, Nam-Gu, Pohang 37673, Korea
| | - Yeong-Rok Kang
- Dongnam Institute of Radiological and Medical Science, 40 Jwadong-Gil, Jangan-Eup, Gijang-Gun, Busan, Korea
| | - Wolsoon Jo
- Dongnam Institute of Radiological and Medical Science, 40 Jwadong-Gil, Jangan-Eup, Gijang-Gun, Busan, Korea
| | - Sookyung Jeong
- Dongnam Institute of Radiological and Medical Science, 40 Jwadong-Gil, Jangan-Eup, Gijang-Gun, Busan, Korea
| | - Sujung Oh
- Dongnam Institute of Radiological and Medical Science, 40 Jwadong-Gil, Jangan-Eup, Gijang-Gun, Busan, Korea
| |
Collapse
|
13
|
Lee Y, Lee WJ, Jin YW, Jang S. Interventional radiologists have a higher rate of chromosomal damage due to occupational radiation exposure: a dicentric chromosome assay. Eur Radiol 2021; 31:8256-8263. [PMID: 33876297 DOI: 10.1007/s00330-021-07883-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 02/14/2021] [Accepted: 03/15/2021] [Indexed: 01/01/2023]
Abstract
OBJECTIVES There are growing concerns regarding radiation exposure in medical workers who perform interventional fluoroscopy procedures. Owing to the nature of certain interventional procedures, workers may be subjected to partial-body radiation exposure that is high enough to cause local damage. We aimed to investigate the level of radiation exposure in interventional radiologists in South Korea by performing cytogenetic biodosimetry, particularly focusing on partial-body exposure. METHODS Interventional radiologists (n = 52) completed a questionnaire, providing information about their work history and practices. Blood samples were collected and processed for a dicentric chromosome assay. We determined Papworth's U-value to assess the conformity of dicentrics with the Poisson distribution to estimate the partial-body exposures of the radiologists. RESULTS Radiologists had a higher number of dicentrics than the normal population and industrial radiographers. Indeed, subjects with a U-value of > 1.96, an indicator of heterogeneous exposure, were observed more frequently; 4.67 ± 0.81% of their body was irradiated at an average dose of 4.64 ± 0.67 Gy. Logistic regression analysis revealed that the total duration of all interventional procedures per week was associated with partial-body exposure levels. CONCLUSIONS Our findings suggest that interventional radiologists had greater chromosomal damages than those in other occupational groups, and their partial-body exposure levels might be high enough to cause local damage. Use of special dosimeters to monitor partial-body exposure, as well as restricting the time and frequency of interventional procedures, could help reduce occupational radiation exposure. KEY POINTS • Interventional radiologists had a higher number of dicentrics than the normal population and industrial radiographers. • The level of partial-body exposure of interventional radiologists might be high enough to cause occupational local damage such as a skin cancer in fingers. • Restricting the duration and frequency of interventional procedures might be helpful in reducing occupational radiation exposure.
Collapse
Affiliation(s)
- Younghyun Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea
| | - Won Jin Lee
- Department of Preventive Medicine, Korea University College of Medicine, Seoul, Republic of Korea
| | - Young Woo Jin
- National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea
| | - Seongjae Jang
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea.
| |
Collapse
|