1
|
Rossiter N. Invited commentary: A low-cost, DIY tourniquet simulator with built-in self-assessment for prehospital providers in Guatemala City. World J Surg 2024; 48:1290-1291. [PMID: 38768027 DOI: 10.1002/wjs.12196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Accepted: 04/22/2024] [Indexed: 05/22/2024]
|
2
|
Lechner R, Oberst A, Beres Y, Mayer B, Kulla M, Hossfeld B, Gässler H. COMBAT-C: COntrol of Major Bleeding by Application of Tourniquets over Clothing. BMC Emerg Med 2024; 24:90. [PMID: 38816683 PMCID: PMC11141013 DOI: 10.1186/s12873-024-01005-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 05/10/2024] [Indexed: 06/01/2024] Open
Abstract
INTRODUCTION External bleeding is the leading cause of preventable trauma-related death. In certain circumstances, tourniquet application over clothing may be necessary. Therefore, the aim of this study was to assess the effectiveness of tourniquets over different clothing setups. METHODS Three windlass tourniquets (CAT, SAMXT, SOFTT-W) were applied over nine different clothing setups and without clothing on the Hapmed™ Tourniquet Trainer. We compared each tourniquet in each clothing setup to the tourniquet trainer that was not dressed, and we compared the three tourniquets within each clothing setup concerning blood loss, applied pressure and application time. Regression analysis of the effect of thickness, mean weight, mean deformation, application time, and applied pressure on blood loss was performed. RESULTS Although blood loss was significantly greater in the CAT and SAMXT tourniquets when they were applied over leather motorcycle trousers, the overall findings showed that the clothing setups significantly reduced or did not affect blood loss. The mean blood loss was the lowest with CAT and the highest with SOFTT-W. The measured mean pressures were lower than 180 mmHg in four out of nine clothing setups with SOFTT-W, but CAT and SAMXT always exceeded this threshold. CAT had the fastest application time. Blood loss was significantly influenced by applied pressure and application time but was influenced to a far lesser degree by clothing parameters. CONCLUSION The effects of the clothing setups were of little clinical relevance, except for leather motorcycle trousers. The effects of rugged protective equipment, e.g., hazard suits, are conceivable and need to be tested for specific garments with the tourniquet intended for use. No clothing parameter for predicting tourniquet effectiveness could be identified.
Collapse
Affiliation(s)
- Raimund Lechner
- Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Therapy, Bundeswehr Hospital Ulm, Oberer Eselsberg 40, 89081, Ulm, Germany.
- Medical Service Police Baden-Württemberg, Stuttgart, Germany.
| | - Amelie Oberst
- Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Therapy, Bundeswehr Hospital Ulm, Oberer Eselsberg 40, 89081, Ulm, Germany
| | - Yannick Beres
- Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Therapy, Bundeswehr Hospital Ulm, Oberer Eselsberg 40, 89081, Ulm, Germany
| | - Benjamin Mayer
- Institute for Epidemiology and Medical Biometry, Ulm University, Ulm, Germany
| | - Martin Kulla
- Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Therapy, Bundeswehr Hospital Ulm, Oberer Eselsberg 40, 89081, Ulm, Germany
| | - Björn Hossfeld
- Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Therapy, Bundeswehr Hospital Ulm, Oberer Eselsberg 40, 89081, Ulm, Germany
| | - Holger Gässler
- Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Therapy, Bundeswehr Hospital Ulm, Oberer Eselsberg 40, 89081, Ulm, Germany
| |
Collapse
|
3
|
Ronconi RWF, Moreira LH, de Lima CJ, Neto OP, Osorio RAL. Tourniquets, types and techniques in emergency prehospital care: A narrative review. Med Eng Phys 2023; 111:103923. [PMID: 36792231 DOI: 10.1016/j.medengphy.2022.103923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 10/19/2022] [Accepted: 11/15/2022] [Indexed: 11/18/2022]
Abstract
Massive uncontrolled hemorrhage is an important cause of preventable death in trauma. Therefore, applying an arterial tourniquet (TQ) is recommended as a pre-hospital measure to control bleeding after severe traumatic bleeding. Limb TQ applies circumferential compression proximally to the injury site to compress the arteries, resulting in blood flow and consequently hemorrhage interruption. The use of commercial tourniquets (C-TQ), which are designed, tested, and registered to control hemorrhages in pre-hospital care, is a consensus. However, they are still uncommon in many prehospital emergency services and the overall level of evidence in most studies is low. This narrative review aimed to characterize the importance of tourniquets use in prehospital emergency care and its application techniques. Furthermore, it proposes to stimulate the development of new devices, more accessible and easier to use, to suggest new directions of studies and medical education demands, with manikin and simulation development.
Collapse
Affiliation(s)
- Roger William Freire Ronconi
- Biomedical Engineering Institute, Universidade Anhembi Morumbi UAM, São José dos Campos, São Paulo, Brazil; Biomedical Engineering Department, Center for Innovation, Technology and Education CITE, São José dos Campos, São Paulo, Brazil; Tacmed Brasil, Taubaté, São Paulo, Brazil.
| | - Livia Helena Moreira
- Biomedical Engineering Institute, Universidade Anhembi Morumbi UAM, São José dos Campos, São Paulo, Brazil; Biomedical Engineering Department, Center for Innovation, Technology and Education CITE, São José dos Campos, São Paulo, Brazil
| | - Carlos José de Lima
- Biomedical Engineering Institute, Universidade Anhembi Morumbi UAM, São José dos Campos, São Paulo, Brazil; Biomedical Engineering Department, Center for Innovation, Technology and Education CITE, São José dos Campos, São Paulo, Brazil
| | - Osmar Pinto Neto
- Biomedical Engineering Institute, Universidade Anhembi Morumbi UAM, São José dos Campos, São Paulo, Brazil; Biomedical Engineering Department, Center for Innovation, Technology and Education CITE, São José dos Campos, São Paulo, Brazil; Arena235 Research Lab, São José dos Campos, São Paulo, Brazil
| | - Rodrigo Alexis Lazo Osorio
- Biomedical Engineering Institute, Universidade Anhembi Morumbi UAM, São José dos Campos, São Paulo, Brazil; Biomedical Engineering Department, Center for Innovation, Technology and Education CITE, São José dos Campos, São Paulo, Brazil
| |
Collapse
|
4
|
Yu H, Wang S, Song Q, You Y, Bao J, Yao M. Delayed femoral vein ligation reduces operative time and blood loss during hip disarticulation in patients with extremity tumors. Open Med (Wars) 2022; 17:1705-1711. [PMID: 36382056 PMCID: PMC9616051 DOI: 10.1515/med-2021-0372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 08/22/2021] [Accepted: 09/15/2021] [Indexed: 12/12/2022] Open
Abstract
This study aimed to evaluate the effects of delayed femoral vein ligation on the clinical outcomes of hip disarticulation. We retrospectively reviewed 20 patients with extremity tumors (10 bone tumors and 10 soft tissue sarcomas [STS]) who underwent hip disarticulation. Patients treated for hip disarticulation with synchronous femoral vein ligation (n = 10, regular surgery group) and hip disarticulation with delayed femoral vein ligation (n = 10, delayed ligation group), respectively, were enrolled in this study. The operative time and blood loss were used to evaluate the clinical outcomes. The delayed ligation group had significantly lower operative times than the regular surgery group (P < 0.05). Total, hidden, and intraoperative blood loss were all significantly lower in the delayed ligation group than in the regular surgery group (P < 0.05). However, there were no significant differences in postoperative blood loss. In conclusion, delayed femoral vein ligation could significantly reduce the operative time, hidden blood loss, and intraoperative blood loss in patients undergoing hip disarticulation.
Collapse
Affiliation(s)
- Hongwei Yu
- Department of Orthopaedics, The Tumor Hospital Affiliated to Harbin Medical University, Harbin, Heilongjiang, China
| | - ShuHuai Wang
- Department of Pathology, The Tumor Hospital Affiliated to Harbin Medical University,
Harbin, Heilongjiang, China
| | - Qi Song
- Department of Orthopaedics, The Hospital of Orthopaedics and Traumatology in Harbin,
Harbin, Heilongjiang, China
| | - Yan You
- Dermatology Department, The Fourth Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China
| | - Junjie Bao
- Department of Orthopaedics, The Tumor Hospital Affiliated to Harbin Medical University, Harbin, Heilongjiang, China
| | - Meng Yao
- Department of Orthopaedics, The Second Affiliated Hospital of Harbin Medical University, No. 246, Xuefu Road, Nangang District, Harbin 150001, Heilongjiang, China
| |
Collapse
|
5
|
A Comparison of Improvised and Commercially Available Point-of-Wounding Tourniquets in Simulated Traumatic Amputation With Catastrophic Haemorrhage: Corrigendum. Mil Med 2021; 186:e463. [PMID: 33404604 DOI: 10.1093/milmed/usaa535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Indexed: 11/13/2022] Open
|
6
|
Herron JBT, Hay David A, Hodgetts TJ. Tourni-key application times compared with a Combat Application Tourniquet in trained and untrained populations. BMJ Mil Health 2020; 167:142-143. [PMID: 33109733 DOI: 10.1136/bmjmilitary-2020-001662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Accepted: 09/26/2020] [Indexed: 11/04/2022]
Affiliation(s)
| | | | - T J Hodgetts
- British Army Land Forces Headquarters, Andover, Hampshire, UK
| |
Collapse
|