Chen LG, Kao HW, Wu PA, Sheu MH, Huang LC. Optimal image quality and radiation doses with optimal tube voltages/currents for pediatric anthropomorphic phantom brains. PLoS One 2024; 19:e0306857. [PMID: 39037987 PMCID: PMC11262643 DOI: 10.1371/journal.pone.0306857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Accepted: 06/25/2024] [Indexed: 07/24/2024] Open
Abstract
OBJECTIVE Using pediatric anthropomorphic phantoms (APs), we aimed to determine the scanning tube voltage/current combinations that could achieve optimal image quality and avoid excessive radiation exposure in pediatric patients. MATERIALS AND METHODS A 64-slice scanner was used to scan a standard test phantom to determine the volume CT dose indices (CTDIvol), and three pediatric anthropomorphic phantoms (APs) with highly accurate anatomy and tissue-equivalent materials were studied. These specialized APs represented the average 1-year-old, 5-year-old, and 10-year-old children, respectively. The physical phantoms were constructed with brain tissue-equivalent materials having a density of ρ = 1.07 g/cm3, comprising 22 numbered 2.54-cm-thick sections for the 1-year-old, 26 sections for the 5-year-old, and 32 sections for the 10-year-old. They were scanned to acquire brain CT images and determine the standard deviations (SDs), effective doses (EDs), and contrast-to noise ratios (CNRs). The APs were scanned by 21 combinations of tube voltages/currents (80, 100, or 120 kVp/10, 40, 80, 120, 150, 200, or 250 mA) and rotation time/pitch settings of 1 s/0.984:1. RESULTS The optimal tube voltage/current combinations yielding optimal image quality were 80 kVp/80 mA for the 1-year-old AP; 80 kVp/120 mA for the 5-year-old AP; and 80 kVp/150 mA for the 10-year-old AP. Because these scanning tube voltages/currents yielded SDs, respectively, of 12.81, 13.09, and 12.26 HU, along with small EDs of 0.31, 0.34, and 0.31 mSv, these parameters and the induced values were expediently defined as optimal. CONCLUSIONS The optimal tube voltages/currents that yielded optimal brain image quality, SDs, CNRs, and EDs herein are novel and essentially important. Clinical translation of these optimal values may allow CT diagnosis with low radiation doses to children's heads.
Collapse
Affiliation(s)
- Li-Guo Chen
- Department of Medical Imaging, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
| | - Hung-Wen Kao
- Department of Medical Imaging, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
- Department of Radiology, School of Medicine, Tzu Chi University, Hualien, Taiwan
| | - Ping-An Wu
- Department of Medical Imaging, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
| | - Ming-Huei Sheu
- Department of Medical Imaging, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
| | - Li-Chuan Huang
- Department of Medical Imaging, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
- Department of Medical Imaging and Radiological Sciences, Tzu Chi University of Science and Technology, Hualien, Taiwan
| |
Collapse
|
2
|
Yamauchi-Kawaura C, Fujii K, Yamauchi M, Imai K, Ikeda M, Narai K, Shimizu H. DEVELOPMENT OF A JAPANESE INFANT HEAD-CHEST PHANTOM AND INVESTIGATION OF THE CURRENT STATUS OF INFANT HEAD CT EXAMINATIONS IN JAPAN. RADIATION PROTECTION DOSIMETRY 2020; 188:65-72. [PMID: 31836891 DOI: 10.1093/rpd/ncz261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Accepted: 09/12/2019] [Indexed: 06/10/2023]
Abstract
The aim of this study was to develop a head-chest phantom that could mimic the physique of a Japanese 0.5-year-old child and to investigate the current status of exposure dose in infant head computed tomography examinations in Japan. The phantom was produced by machine processing, and radiophotoluminescence glass dosemeters were installed in the phantom for dose measurement. Organ doses were measured for seven different head scan protocols routinely used in three hospitals. In this study, the average dose of the brain and lens within the scan region was equivalent to that measured using infant phantoms in previous studies. In contrast, the doses of both salivary glands and thyroid glands adjacent to the scan region were 1.4-1.8 times higher than those in previous studies. Expansion of the scan area accompanied by a transition of the scan mode from non-helical to helical may have resulted in the differences in organ doses.
Collapse
Affiliation(s)
- C Yamauchi-Kawaura
- Department of Radiological Sciences, Graduate School of Medicine, Nagoya University, 1-1-20 Daikominami, Higashi-ku, Nagoya 461-8673, Japan
| | - K Fujii
- Department of Radiological Sciences, Graduate School of Medicine, Nagoya University, 1-1-20 Daikominami, Higashi-ku, Nagoya 461-8673, Japan
| | - M Yamauchi
- Division of Radiology, Aichi Medical University Hospital, Nagakute, Aichi 480-1195, Japan
| | - K Imai
- Department of Radiological Sciences, Graduate School of Medicine, Nagoya University, 1-1-20 Daikominami, Higashi-ku, Nagoya 461-8673, Japan
| | - M Ikeda
- Department of Radiological Sciences, Graduate School of Medicine, Nagoya University, 1-1-20 Daikominami, Higashi-ku, Nagoya 461-8673, Japan
| | - K Narai
- Techno-Rad, Inc., 50-8, Higashi Arami, Tai, Miyama-cho, Kuze-gun, Kyoto 613-0036, Japan
| | - H Shimizu
- Department of Radiation Oncology, Aichi Cancer Center Hospital, 1-1 Kanokoden, Chikusa-ku, Nagoya 464-8681, Japan
| |
Collapse
|
3
|
Lin HC, Lai TJ, Tseng HC, Wang CH, Tseng YL, Chen CY. Radiation doses with various body weights of phantoms in brain 128-slice MDCT examination. JOURNAL OF RADIATION RESEARCH 2019; 60:466-475. [PMID: 31197311 PMCID: PMC6640898 DOI: 10.1093/jrr/rrz029] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 04/15/2019] [Indexed: 06/09/2023]
Abstract
The effective dose (HE) and organ or tissue equivalent dose (HT) for use in brain computed tomography (CT) examinations with various body weights were evaluated. Thermoluminescent dosimeters (TLD-100H) were inserted into Rando and five anthropomorphic phantoms. These phantoms were made of polymethylmethacrylate (PMMA), according to the specifications of ICRU 48, with masses from 10 to 90 kg. Brain CT examinations were conducted, scanning the maxillae from the external auditory meatus to the parietal bone using a 128-slice multi-detector CT (MDCT) scanner. To reduce errors, three independent trials were conducted. Calculated HE,TLD, based on the weighting factor recommended by ICRP 103, was 1.72 ± 0.28 mSv, which slightly exceeds the HE,DLP of 1.70 mSv, that was calculated from the dose-length product (DLP) of the Rando phantom. This experiment yielded HE,TLD values of ICRP 103 from the highest 1.85 ± 0.28 (90 kg) to the lowest 1.47 ± 0.22 (10 kg) mSv. HE,TLD (mSv) = 5.45×10-3 W(kg) + 1.361, with an R2 of 0.87667. Using the DLP protocol, HE,DLP was estimated from CTDIvol that was recorded directly from the console display of the CT unit and multiplied by the conversion coefficient (k) recommended by the ICRP 103. Finally, the experimental results obtained herein are compared with those in the literature. Physicians should choose and adjust protocols to prevent the exposure of patients to unnecessary radiation, satisfying the as low as reasonably achievable (ALARA) principle. These findings will be valuable to patients, physicians, radiologists and the public.
Collapse
Affiliation(s)
- Hung-Chih Lin
- Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan, Republic of China
- Department of Radiology, Lukang Christian Hospital of Changhua Christian, Medical Foundation, Lukang, Taiwan, Republic of China
| | - Te-Jen Lai
- Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan, Republic of China
- Department of Psychiatry, Chung Shan Medical University Hospital, Chung Shan Medical University, Taichung, Taiwan, Republic of China
| | - Hsien-Chun Tseng
- School of Medicine, Chung Shan Medical University, Taichung, Taiwan, Republic of China
- Department of Radiation Oncology, Chung Shan Medical University Hospital, Chung Shan Medical University, Taichung, Taiwan, Republic of China
| | - Ching-Hsiang Wang
- Department of Radiology, Lukang Christian Hospital of Changhua Christian, Medical Foundation, Lukang, Taiwan, Republic of China
| | - Yen-Ling Tseng
- Department of Radiology, Lukang Christian Hospital of Changhua Christian, Medical Foundation, Lukang, Taiwan, Republic of China
| | - Chien-Yi Chen
- Department of Radiation Oncology, Chung Shan Medical University Hospital, Chung Shan Medical University, Taichung, Taiwan, Republic of China
- Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, Taichung, Taiwan, Republic of China
| |
Collapse
|
4
|
Majer M, Knežević Ž, Liu H, Hršak H, Miljanić S, Zhuo W, Heinrich Z. Paediatric organ doses from CT-simulation in brain tumour GK radiosurgery treatment – Phantom study. RADIAT MEAS 2017. [DOI: 10.1016/j.radmeas.2017.03.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
5
|
Santos J, Foley S, Paulo G, McEntee MF, Rainford L. The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography. Pediatr Radiol 2015; 45:1814-22. [PMID: 26242810 DOI: 10.1007/s00247-015-3398-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Revised: 03/28/2015] [Accepted: 06/01/2015] [Indexed: 10/23/2022]
Abstract
BACKGROUND The volume of CT examinations has increased with resultant increases in collective dose values over the last decade. OBJECTIVE To analyze the impact of the tube current and voltage modulation for dose values and image quality of pediatric head CT examinations. MATERIALS AND METHODS Head CT examinations were performed on anthropomorphic phantoms and four pediatric age categories before and after the introduction of dedicated pediatric curves for tube voltage and current modulation. Local diagnostic reference levels were calculated. Visual grading characteristic image quality evaluation was performed by four pediatric neuroradiologists and image noise comparisons were performed. RESULTS Pediatric-specific modulation curves demonstrated a 49% decrease in mean radiation dose for phantom examinations. The local diagnostic reference levels (CTDIvol) for clinical examinations decreased by 52%, 41%, 46% and 40% for newborn, 5-, 10- and 15-year-old patients, respectively. Visual grading characteristic image quality was maintained for the majority of age categorizations (area under the curve = 0.5) and image noise measurements did not change (P = 0.693). CONCLUSION Pediatric-specific dose modulation curves resulted in an overall mean dose reduction of 45% with no significant differences in subjective or objective image quality findings.
Collapse
Affiliation(s)
- Joana Santos
- Instituto Politécnico de Coimbra, ESTESC, DMIR, Rua 5 de Outubro, S. Martinho do Bispo, 3046-854, Coimbra, Portugal.
| | - Shane Foley
- School of Medicine & Medical Science, Health Science Centre, University College Dublin, Belfield, Dublin 4, Ireland
| | - Graciano Paulo
- Instituto Politécnico de Coimbra, ESTESC, DMIR, Rua 5 de Outubro, S. Martinho do Bispo, 3046-854, Coimbra, Portugal
| | - Mark F McEntee
- Faculty of Health Sciences, Cumberland Campus, The University of Sydney, Sydney, Australia
| | - Louise Rainford
- School of Medicine & Medical Science, Health Science Centre, University College Dublin, Belfield, Dublin 4, Ireland
| |
Collapse
|
6
|
Yamauchi-Kawaura C, Fujii K, Akahane K, Yamauchi M, Narai K, Aoyama T, Katsu T, Obara S, Imai K, Ikeda M. Development of age-specific Japanese head phantoms for dose evaluation in paediatric head CT examinations. RADIATION PROTECTION DOSIMETRY 2015; 163:188-201. [PMID: 24821932 DOI: 10.1093/rpd/ncu155] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In this study, the authors developed age-specific physical head phantoms simulating the physique of Japanese children for dose evaluation in paediatric head computed tomography (CT) examinations. Anatomical structures at 99 places in 0-, 0.5-, 1- and 3-y-old Japanese patients were measured using DICOM viewer software from CT images, and the head phantom of each age was designed. For trial manufacture, a 3-y-old head phantom consisting of acrylic resin and gypsum was produced by machine processing. Radiation doses for the head phantom were measured with radiophotoluminescence glass dosemeters and Si-pin photodiode dosemeters. To investigate whether the phantom shape was suitable for dose evaluation, organ doses in the same scan protocol were compared between the 3-y-old head and commercially available anthropomorphic phantoms having approximately the same head size. The doses of organs in both phantoms were equivalent. The authors' designed paediatric head phantom will be useful for dose evaluation in paediatric head CT examinations.
Collapse
Affiliation(s)
- C Yamauchi-Kawaura
- Department of Radiological Sciences, Graduate School of Medicine, Nagoya University, 1-1-20 Daikominami, Higashi-ku, Nagoya 461-8673, Japan
| | - K Fujii
- Department of Radiological Sciences, Graduate School of Medicine, Nagoya University, 1-1-20 Daikominami, Higashi-ku, Nagoya 461-8673, Japan
| | - K Akahane
- Radiological Protection Section, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
| | - M Yamauchi
- Division of Radiology, Aichi Medical University Hospital, Nagakute, Aichi 480-1195, Japan
| | - K Narai
- Techno-Rad, Inc., 50-8, Higashi Arami, Tai, Miyama-cho, Kuze-gun, Kyoto 613-0036, Japan
| | - T Aoyama
- Department of Radiological Sciences, Graduate School of Medicine, Nagoya University, 1-1-20 Daikominami, Higashi-ku, Nagoya 461-8673, Japan
| | - T Katsu
- Division of Radiology, Nagoya University Hospital, Tsurumai-cho, Showa-ku, Nagoya 466-8560, Japan
| | - S Obara
- Radiological Protection Section, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
| | - K Imai
- Department of Radiological Sciences, Graduate School of Medicine, Nagoya University, 1-1-20 Daikominami, Higashi-ku, Nagoya 461-8673, Japan
| | - M Ikeda
- Department of Radiological Sciences, Graduate School of Medicine, Nagoya University, 1-1-20 Daikominami, Higashi-ku, Nagoya 461-8673, Japan
| |
Collapse
|
7
|
Yamauchi-Kawaura C, Yamauchi M, Imai K, Ikeda M, Aoyama T. Image quality and age-specific dose estimation in head and chest CT examinations with organ-based tube-current modulation. RADIATION PROTECTION DOSIMETRY 2013; 157:193-205. [PMID: 23734058 DOI: 10.1093/rpd/nct137] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The purpose of this study was to investigate the effects of an organ-based tube-current modulation (OBTCM) system on image quality and age-specific dose in head and chest CT examinations. Image noise, contrast-to-noise ratio (CNR) and image entropy were assessed using statistical and entropy analyses. Radiation doses for newborn, 6-y-old child and adult phantoms were measured with in-phantom dosimetry systems. The quality of CT images obtained with OBTCM was not different from that obtained without OBTCM. In head CT scans, the eye lens dose decreased by 20-33 % using OBTCM. In chest CT scans, breast dose decreased by 5-32 % using OBTCM. Posterior skin dose, however, increased by 11-20 % using OBTCM in head and chest CT scans. The reduction of effective dose using OBTCM was negligibly small. Detailed image quality and dose information provided in this study can be effectively used for OBTCM application.
Collapse
Affiliation(s)
- C Yamauchi-Kawaura
- Department of Radiological Sciences, Graduate School of Medicine, Nagoya University, 1-1-20 Daikominami, Higashi-ku, Nagoya 461-8673, Japan
| | | | | | | | | |
Collapse
|