1
|
de Paula A, Gattazzo I, Savini G, Schiano Lomoriello D, Corsi A. An analysis of the factors involved in IOL decentration after phacoemulsification using CASIA 2 anterior segment optical coherence tomography. Int Ophthalmol 2024; 44:194. [PMID: 38656707 DOI: 10.1007/s10792-024-03126-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Accepted: 04/11/2024] [Indexed: 04/26/2024]
Abstract
PURPOSE To evaluate the magnitude of IOL transversal shift (ITS) after phacoemulsification and to analyse the factors contributing to IOL decentration and ITS. METHODS 94 consecutive patients who underwent cataract surgery and IOL implantation was enrolled. Each patient underwent anterior segment optical coherence tomography with CASIA 2 (Tomey, Nagoya, Japan) to assess crystalline lens decentration, thickness and diameter seven days preoperatively and at one and sixty days postoperatively. Univariate and multivariate linear regression analysis were performed to evaluate the determinants of ITS and final decentration. RESULTS The preoperative crystalline lens diameter was associated with the ITS and with the IOL final decentration. A positive association between the final IOL decentration and the first post-surgical day decentration was found (p < 0.0001). CONCLUSION Greater crystalline lens diameter was associated with greater decentration and with greater ITS. Day-one IOL decentration seems to be the main determinant of final IOL decentration.
Collapse
Affiliation(s)
- Alessandro de Paula
- Ophthalmology Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy.
| | - Irene Gattazzo
- Ophthalmology Unit, NESMOS Department, St. Andrea Hospital, University of Rome "La Sapienza", Rome, Italy
| | | | | | - Andrea Corsi
- Ophthalmology Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy
| |
Collapse
|
2
|
Srinivasan K, Sakthivel S. Classic anterior lenticonus in Alport syndrome. J Fr Ophtalmol 2024; 47:104120. [PMID: 38447292 DOI: 10.1016/j.jfo.2024.104120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 09/04/2023] [Accepted: 10/08/2023] [Indexed: 03/08/2024]
Affiliation(s)
- K Srinivasan
- Department of Glaucoma, Aravind Eye Hospital,Thavalakuppam, 605007 Puducherry, India.
| | - S Sakthivel
- Department of Glaucoma, Aravind Eye Hospital,Thavalakuppam, 605007 Puducherry, India
| |
Collapse
|
3
|
Guo M, Higashita R, Lin C, Hu L, Chen W, Li F, Lai GWK, Nguyen A, Sakata R, Okamoto K, Tang B, Xu Y, Fu H, Gao F, Aihara M, Zhang X, Yuan J, Lin S, Leung CKS, Liu J. Crystalline lens nuclear age prediction as a new biomarker of nucleus degeneration. Br J Ophthalmol 2024; 108:513-521. [PMID: 37495263 DOI: 10.1136/bjo-2023-323176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 05/22/2023] [Indexed: 07/28/2023]
Abstract
BACKGROUND The crystalline lens is a transparent structure of the eye to focus light on the retina. It becomes muddy, hard and dense with increasing age, which makes the crystalline lens gradually lose its function. We aim to develop a nuclear age predictor to reflect the degeneration of the crystalline lens nucleus. METHODS First we trained and internally validated the nuclear age predictor with a deep-learning algorithm, using 12 904 anterior segment optical coherence tomography (AS-OCT) images from four diverse Asian and American cohorts: Zhongshan Ophthalmic Center with Machine0 (ZOM0), Tomey Corporation (TOMEY), University of California San Francisco and the Chinese University of Hong Kong. External testing was done on three independent datasets: Tokyo University (TU), ZOM1 and Shenzhen People's Hospital (SPH). We also demonstrate the possibility of detecting nuclear cataracts (NCs) from the nuclear age gap. FINDINGS In the internal validation dataset, the nuclear age could be predicted with a mean absolute error (MAE) of 2.570 years (95% CI 1.886 to 2.863). Across the three external testing datasets, the algorithm achieved MAEs of 4.261 years (95% CI 3.391 to 5.094) in TU, 3.920 years (95% CI 3.332 to 4.637) in ZOM1-NonCata and 4.380 years (95% CI 3.730 to 5.061) in SPH-NonCata. The MAEs for NC eyes were 8.490 years (95% CI 7.219 to 9.766) in ZOM1-NC and 9.998 years (95% CI 5.673 to 14.642) in SPH-NC. The nuclear age gap outperformed both ophthalmologists in detecting NCs, with areas under the receiver operating characteristic curves of 0.853 years (95% CI 0.787 to 0.917) in ZOM1 and 0.909 years (95% CI 0.828 to 0.978) in SPH. INTERPRETATION The nuclear age predictor shows good performance, validating the feasibility of using AS-OCT images as an effective screening tool for nucleus degeneration. Our work also demonstrates the potential use of the nuclear age gap to detect NCs.
Collapse
Affiliation(s)
- Mengjie Guo
- Research Institute of Trustworthy Autonomous Systems, Southern University of Science and Technology, Shenzhen, Guangdong, China
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China
| | - Risa Higashita
- Department of Computer Science and Engineering, Southern University of Science and Technology, Shenzhen, Guangdong, China
- Tomey Corporation, Nagoya, Aichi, Japan
| | - Chen Lin
- Shenzhen People's Hospital, Shenzhen, Guangdong, China
| | - Lingxi Hu
- Research Institute of Trustworthy Autonomous Systems, Southern University of Science and Technology, Shenzhen, Guangdong, China
| | - Wan Chen
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Fei Li
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Gilda Wing Ki Lai
- Department of Ophthalmology, The University of Hong Kong, Hong Kong, Hong Kong
| | - Anwell Nguyen
- Department of Ophthalmology, University of California, San Francisco, California, USA
| | - Rei Sakata
- Department of Ophthalmology, The University of Tokyo, Tokyo, Japan
| | | | - Bo Tang
- Research Institute of Trustworthy Autonomous Systems, Southern University of Science and Technology, Shenzhen, Guangdong, China
| | - Yanwu Xu
- Intelligent Healthcare Unit, Baidu Inc, Beijing, China
| | - Huazhu Fu
- Institute of High Performance Computing, Agency for Science, Technology and Research, Singapore
| | - Fei Gao
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China
| | - Makoto Aihara
- Department of Ophthalmology, The University of Tokyo, Tokyo, Japan
| | - Xiulan Zhang
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Jin Yuan
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Shan Lin
- Department of Ophthalmology, University of California, San Francisco, California, USA
- Glaucoma Center of San Francisco, San Francisco, California, USA
| | - Christopher Kai-Shun Leung
- Department of Ophthalmology, The University of Hong Kong, Hong Kong, Hong Kong
- Department of Ophthalmology and Visual Sciences, The Chinese University, Hong Kong, Hong Kong
| | - Jiang Liu
- Research Institute of Trustworthy Autonomous Systems, Southern University of Science and Technology, Shenzhen, Guangdong, China
- Department of Computer Science and Engineering, Southern University of Science and Technology, Shenzhen, Guangdong, China
- Cixi Institute of Biomedical Engineering, Chinese Academy of Sciences, Cixi, Zhejiang, China
| |
Collapse
|
4
|
Perdomo AA, Badawy MK, Mignone C, Forster JC. Exceeding radiation thresholds for cataract induction in diagnostic imaging: a paediatric case report. Radiat Prot Dosimetry 2024; 200:417-422. [PMID: 38195763 DOI: 10.1093/rpd/ncad310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 11/17/2023] [Accepted: 12/06/2023] [Indexed: 01/11/2024]
Abstract
This case report investigates the radiation dose received by a paediatric patient with a ventricular assist device who underwent four non-contrast brain computed tomography (CT) scans, two brain perfusion CT scans and two head angiographic CT scans. The total estimated absorbed dose to the lens of the eye is above the 500 mGy radiation-induced cataract threshold. It is recommended that this patient and those with similar imaging histories have routine follow-up with an ophthalmologist. It is also recommended that radiation dose tracking and an electronic medical alert program be implemented to allow the identification of patients who may exceed tissue reaction thresholds.
Collapse
Affiliation(s)
- Amanda Alison Perdomo
- Department of Physics, University of Adelaide, Adelaide 5005, South Australia, Australia
- Department of Medical Imaging, The Royal Children's Hospital, 50 Flemington Road, Parkville 3052, Victoria, Australia
| | - Mohamed Khaldoun Badawy
- Monash Health Imaging, Monash Health, 246 Clayton Rd, Clayton 3168, Victoria, Australia
- Department of Medical Imaging and Radiation Sciences, School of Primary and Allied Health Care, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton 3800, VIC, Australia
| | - Cristina Mignone
- Department of Medical Imaging, The Royal Children's Hospital, 50 Flemington Road, Parkville 3052, Victoria, Australia
| | - Jake Cameron Forster
- Department of Physics, University of Adelaide, Adelaide 5005, South Australia, Australia
- Medical Physics & Radiation Safety, South Australia Medical Imaging, Adelaide 5005, South Australia, Australia
| |
Collapse
|
5
|
von der Emde L, Rennen GC, Vaisband M, Hasenauer J, Liegl R, Fleckenstein M, Pfau M, Holz FG, Ach T. Personalized Lens Correction Improves Quantitative Fundus Autofluorescence Analysis. Invest Ophthalmol Vis Sci 2024; 65:13. [PMID: 38466288 DOI: 10.1167/iovs.65.3.13] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2024] Open
Abstract
Purpose Quantitative fundus autofluorescence (QAF) currently deploys an age-based score to correct for lens opacification. However, in elderly people, lens opacification varies strongly between individuals of similar age, and innate lens autofluorescence is not included in the current correction formula. Our goal was to develop and compare an individualized formula. Methods One hundred thirty participants were examined cross-sectionally, and a subset of 30 participants received additional multimodal imaging 2-week post-cataract-surgery. Imaging included the Scheimpflug principle, anterior chamber optical coherence tomography (AC-OCT), lens quantitative autofluorescence (LQAF), and retinal QAF imaging. Among the subset, least absolute shrinkage and selection operator regression and backward selection was implemented to determine which lens score best predicts the QAF value after lens extraction. Subsequently, a spline mixed model was applied to the whole cohort to quantify the influence of LQAF and Scheimpflug on QAF. Results Age and LQAF measurements were found to be the most relevant variables, whereas AC-OCT measurements and Scheimpflug were eliminated by backward selection. Both an increase in Scheimpflug and LQAF values were associated with a decrease in QAF. The prediction error of the spline model (mean absolute error [MAE] ± standard deviation) of 32.2 ± 23.4 (QAF a.u.) was markedly lower compared to the current age-based formula MAE of 96.1 ± 93.5. Both smooth terms, LQAF (P < 0.01) and Scheimpflug (P < 0.001), were significant for the spline mixed model. Conclusions LQAF imaging proved to be the most predictive for the impact of the natural lens on QAF imaging. The application of lens scores in the clinic could improve the accuracy of QAF imaging interpretation and might allow including aged patients in future QAF studies.
Collapse
Affiliation(s)
- Leon von der Emde
- Department of Ophthalmology, University Hospital Bonn, Bonn, Germany
| | - Geena C Rennen
- Department of Ophthalmology, University Hospital Bonn, Bonn, Germany
| | - Marc Vaisband
- University of Bonn, Life and Medical Sciences Institute, Bonn, Germany
- Department of Internal Medicine III with Haematology, Medical Oncology, Haemostaseology, Infectiology and Rheumatology, Oncologic Center; Salzburg Cancer Research Institute-Laboratory for Immunological and Molecular Cancer Research (SCRI-LIMCR); Paracelsus Medical University, Salzburg, Austria, Cancer Cluster Salzburg, Austria
| | - Jan Hasenauer
- University of Bonn, Life and Medical Sciences Institute, Bonn, Germany
- Helmholtz Center Munich-German Research Center for Environmental Health, Institute of Computational Biology, Neuherberg, Germany
| | - Raffael Liegl
- Department of Ophthalmology, University Hospital Bonn, Bonn, Germany
| | - Monika Fleckenstein
- Department of Ophthalmology and Visual Science, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, United States
| | - Maximilian Pfau
- Institute of Molecular and Clinical Ophthalmology Basel, Mittlere Strasse 91, Basel, Switzerland
| | - Frank G Holz
- Department of Ophthalmology, University Hospital Bonn, Bonn, Germany
| | - Thomas Ach
- Department of Ophthalmology, University Hospital Bonn, Bonn, Germany
| |
Collapse
|
6
|
Lin HS, Zhou MT, Li JX, Zheng XL, Ding YT, Ji YT, Wang XJ, Xie YQ, Liang YB. Central anterior chamber depth correlated with white-to-white distance in normal, long, and short eyes. Int Ophthalmol 2024; 44:34. [PMID: 38332205 DOI: 10.1007/s10792-024-03014-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2023] [Accepted: 01/09/2024] [Indexed: 02/10/2024]
Abstract
PURPOSE To explore the associations between central anterior chamber depth (CACD) and other anterior segment biometric parameters and to determine the possible determinants of CACD in short, normal, and long eyes. METHODS The biometric data of pre-operation patients aged 50-80 years with coexisting cataract and primary angle-closure disease or senile cataract were reviewed. Axial length (AL), CACD, lens thickness (LT), central corneal thickness (CCT), and white-to-white distance (WTW) were measured by Lenstar optical biometry (Lenstar 900). The data of 100 normal eyes (AL = 22 to 26 mm), 100 short eyes (AL ≤ 22 mm), and 100 long eyes (AL ≥ 26 mm) were consecutively collected for subsequent analyses. RESULTS The mean age of the subjects was 66.60 ± 7.85 years, with 25.7% of the sample being men. Both CACD and WTW were found to be smallest in short eyes and were smaller in normal eyes than in long eyes (F = 126.524, P < 0.001; F = 28.458, P < 0.001). The mean LT was significantly thicker in short eyes than in normal and long eyes (4.66 mm versus 4.49 mm versus 4.40 mm; F = 18.099, P < 0.001). No significant differences were observed in CCT between the three AL groups (F = 2.135, P = 0.120). Stepwise regression analysis highlighted AL, LT, and WTW as three independent factors associated with CACD in the normal AL group. In the short AL group and long AL group, LT and WTW were independent factors associated with CACD. CONCLUSIONS CACD increases as AL elongates and reaches a peak when AL exceeds 26 mm. Furthermore, CACD showed inverse correlation with LT and positive correlation with WTW. A relatively small WTW results in an anteriorly positioned lens, and thus, a decrease in CACD.
Collapse
Affiliation(s)
- Hai-Shuang Lin
- Wenzhou Medical University, Wenzhou, 325027, Zhejiang Province, China
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, No. 270, Xue Yuan Xi Road, Wenzhou, 3250027, Zhejiang, China
| | - Meng-Tian Zhou
- Wenzhou Medical University, Wenzhou, 325027, Zhejiang Province, China
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, No. 270, Xue Yuan Xi Road, Wenzhou, 3250027, Zhejiang, China
| | - Jin-Xin Li
- Wenzhou Medical University, Wenzhou, 325027, Zhejiang Province, China
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, No. 270, Xue Yuan Xi Road, Wenzhou, 3250027, Zhejiang, China
| | - Xuan-Li Zheng
- Wenzhou Medical University, Wenzhou, 325027, Zhejiang Province, China
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, No. 270, Xue Yuan Xi Road, Wenzhou, 3250027, Zhejiang, China
| | - Yu-Tong Ding
- Wenzhou Medical University, Wenzhou, 325027, Zhejiang Province, China
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, No. 270, Xue Yuan Xi Road, Wenzhou, 3250027, Zhejiang, China
| | - Yi-Ting Ji
- Wenzhou Medical University, Wenzhou, 325027, Zhejiang Province, China
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, No. 270, Xue Yuan Xi Road, Wenzhou, 3250027, Zhejiang, China
| | - Xiao-Jie Wang
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, No. 270, Xue Yuan Xi Road, Wenzhou, 3250027, Zhejiang, China
- Glaucoma Research Institute, Wenzhou Medical University, Wenzhou, 325027, China
| | - Yan-Qian Xie
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, No. 270, Xue Yuan Xi Road, Wenzhou, 3250027, Zhejiang, China
- Glaucoma Research Institute, Wenzhou Medical University, Wenzhou, 325027, China
| | - Yuan-Bo Liang
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, No. 270, Xue Yuan Xi Road, Wenzhou, 3250027, Zhejiang, China.
- Glaucoma Research Institute, Wenzhou Medical University, Wenzhou, 325027, China.
| |
Collapse
|
7
|
Avetisov KS, Chizhonkova EA, Avetisov SE, Andzhelova DV. [Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens]. Vestn Oftalmol 2024; 140:11-18. [PMID: 38450461 DOI: 10.17116/oftalma202414001111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2024]
Abstract
Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommodative components (ciliary zonule and ciliary body), or what can be called the entire anatomical complex of the lens. Optical methods of studying the structures of the anterior segment of the eye, due to iris opacity, allow only to analyze the state of the lens within the natural or medically enlarged pupil width. Visualization of the structures located behind the iris is possible with the use of radiation diagnostic methods, in particular ultrasound biomicroscopy (UBM). PURPOSE This study assesses the state of the anatomical complex of the lens in MS using UBM. MATERIAL AND METHODS The study was carried out on clinical material previously used by us to analyze changes in the fibrous membrane of the eye in MS. At the first stage, the main (19 patients with MS, 38 eyes) and the control (24 patients with myopia, 48 eyes) groups were formed for comparative evaluation. The formed groups were standardized according to the age of the patients and the axial length of the eye. At the second stage, patients with MS were divided into subgroups depending on the absence or presence of biomicroscopic signs of ectopia lentis (22 and 16 eyes, respectively). For UBM, an ultrasound linear sensor with a scanning frequency of 50 MHz was used (Aviso device, Quantel Medical, France). Various biometric UBM indicators were determined: lens thickness, diameter of the lens, lens-axial length factor, iris-lens angle, iris-lens contact distance, posterior chamber depth, length of the fibers of ciliary zonule, thickness of the ciliary body, sclera-ciliary process angle. RESULTS There are changes in the anatomical complex of the lens as a whole in MS (in the lens itself, the ciliary zonule, and the ciliary body), which are characterized by an increase in lens thickness and a decrease in the diameter of the lens, an increase in the length of the fibers of the ciliary zonule and a decrease in the thickness of the ciliary body. At the same time, the displacement of the lens detected by optical biomicroscopy (ectopia lentis) can be considered as an advanced stage of changes in the anatomical complex of the lens. CONCLUSION UBM provides the possibility of full-fledged visualization of all components of the anatomical complex of the lens in terms of both diagnostics, and monitoring of changes in MS. The question of the advisability of including this method in the algorithm for diagnosing ocular manifestations in order to verify the MS remains open. Possible obstacles may be, on the one hand, related to the need for special and expensive equipment, and on the other hand, the absence of a generally accepted «normal» values of UBM indicators of the anatomical complex of the lens.
Collapse
Affiliation(s)
- K S Avetisov
- Krasnov Research Institute of Eye Diseases, Moscow, Russia
| | | | - S E Avetisov
- Krasnov Research Institute of Eye Diseases, Moscow, Russia
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - D V Andzhelova
- Krasnov Research Institute of Eye Diseases, Moscow, Russia
| |
Collapse
|
8
|
He JC. Refractive Index Measurement of the Crystalline Lens in Vivo. Optom Vis Sci 2023; 100:823-832. [PMID: 37890121 PMCID: PMC10841399 DOI: 10.1097/opx.0000000000002081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/29/2023] Open
Abstract
SIGNIFICANCE This study provides a new method to measure the refractive index of crystalline lens in the human eye in vivo . PURPOSE Accessing the refractive index of crystalline lenses in the human eye in vivo has long been a challenge. This study aimed to measure the refractive index of a lens in vivo using an anterior segment optical coherence tomography (AS-OCT) system combined with a Scheimpflug imaging system. METHOD A ray-traceable Scheimpflug imaging was developed and integrated into an AS-OCT system. A theoretical study revealed that the combination of these two systems provides a unique solution for simultaneously measuring the refractive index and the thickness of the lens. The average lens refractive index along the ray pathway ( Nav ) and lens shape were measured for seven subjects. RESULTS The lens Nav along the central ray varies from 1.383 to 1.419 between subjects. The lens refractive index function across the lens diameter varies from subject to subject. The lens Nav increases for accommodated eyes. The thicknesses and profiles of the lenses are also determined. CONCLUSIONS The lens refractive index varies substantially from individual eye to individual eye, not only along the central ray pathway but also for the lens refractive index function across the lens diameter. Ray-traceable Scheimpflug imaging-equipped AS-OCT is useful for testing the refractive index of lenses in the human eye in vivo .
Collapse
|
9
|
Yu Z, Li N, Wang F, Fu J, Xue S, Wang L. Imaging analysis of the biological parameters of the lens in patients with cortical age-related cataracts using ultrasound biomicroscopy. BMC Ophthalmol 2023; 23:480. [PMID: 37993828 PMCID: PMC10666407 DOI: 10.1186/s12886-023-03227-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Accepted: 11/16/2023] [Indexed: 11/24/2023] Open
Abstract
BACKGROUND The spatial position of the lens in patients with cortical age-related cataract (CARC) is unclear. We investigated a basis for the assessment of visual quality after cataract surgery by analysing the ultrasound biomicroscopic characteristics of the biological parameters of the lens in patients with CARC. METHODS In this retrospective study, 119 patients (50 males and 69 females, totalling 238 eyes) with CARC who underwent simple cataract surgery were selected. The lens thickness (LT), axial length (AL), anterior chamber depth (ACD), lens vault (LV), trabecular-iris angle (TIA), iris-lens angle (ILA), iris-lens contact distance (ILCD) were measured by A-scan ultrasound and ultrasound biomicroscopy. The corresponding lens position (LP) and relative lens position (RLP) were calculated. RESULTS LP was greater in men than in women (P < 0.05), LV was smaller in men than in women (P = 0.002), ILA and ILCD were not statistically significant (P = 0.072 and P = 0.854, respectively). There were significant differences in TIA, ILA, and ILCD in the four quadrants (all P < 0.05), with a trend in the distribution of TIA: superior < inferior < nasal < temporal, ILA: nasal < inferior < temporal < superior, and ILCD: superior < temporal < inferior < nasal. CONCLUSIONS The lens protrudes more obviously in females than in males and the lens tilts to a certain extent with the increase of age and tends to be more upward and temporal in the supine position. Therefore, trends in lens-related parameters in patients with CARC should be taken seriously.
Collapse
Affiliation(s)
- Zhiying Yu
- Department of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Na Li
- Department of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Fenglei Wang
- Department of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Jing Fu
- The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Shasha Xue
- Department of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Ling Wang
- Department of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China.
| |
Collapse
|
10
|
Tekcan H, Mangan MS, Celik G, Imamoglu S. Lens factor as an underlying mechanism in primary angle closure with gonioscopically-visualized ciliary body processes. Jpn J Ophthalmol 2023; 67:678-684. [PMID: 37596442 DOI: 10.1007/s10384-023-01021-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Accepted: 07/23/2023] [Indexed: 08/20/2023]
Abstract
PURPOSE To compare the differences in anterior segment parameters between eyes with primary angle closure (PAC) with and without gonioscopically-visualized ciliary body processes (CBP). STUDY DESIGN Prospective, observational, comparative clinical study. METHODS Detailed ocular examinations and gonioscopy were performed in 89 eyes of 89 patients with PAC to determine the visibility of the CBP. Anterior chamber depth (ACD), anterior chamber width, lens thickness (LT), lens vault (LV) and pupil diameter were determined using ultrasound biomicroscopy. The lens-axial length factor (LAF) and relative lens position (RLP) were calculated. All parameters were compared between eyes with and without gonioscopically visible CBP (PAC+CBP and PAC-CBP groups) after adjusting for age and gender. The association of the parameters with visible CBP was analyzed by univariate logistic regression analysis. RESULTS PAC+CBP group included 41 eyes and the PAC-CBP group, 48 eyes. The axial length and ACD were statistically significantly smaller (p = 0.009 and p = 0.005, respectively) and LT, LV and LAF were statistically significantly greater (p = 0.03, p = 0.008 and p = 0.004, respectively) in the PAC+CBP group. In the PAC eyes with glaucoma, the LT, LV and LAF were statistically significantly greater in the PAC+CBP group (p = 0.02, p = 0.001 and p = 0.02, respectively). The LAF had the strongest association with visible CBP in the regression analysis (Odds ratio = 141.70, p = 0.002). CONCLUSION Gonioscopical visualization of ciliary processes may suggest that anterior segment crowding, especially lens factor is the underlying mechanism in PAC. It may provide a practical gonioscopic examination method for predicting the predominant pathophysiology of PAC.
Collapse
Affiliation(s)
- Hatice Tekcan
- Ophthalmology Department, University of Health Sciences, Haydarpasa Numune Research and Training Hospital, Tıbbiye Street, No: 40, Uskudar, Istanbul, Turkey
| | - Mehmet Serhat Mangan
- Ophthalmology Department, University of Health Sciences, Haydarpasa Numune Research and Training Hospital, Tıbbiye Street, No: 40, Uskudar, Istanbul, Turkey.
| | - Gökhan Celik
- Ophthalmology Department, University of Health Sciences, Zeynep Kamil Gynecologic and Pediatric Training Research Hospital, Istanbul, Turkey
| | - Serhat Imamoglu
- Ophthalmology Department, University of Health Sciences, Haydarpasa Numune Research and Training Hospital, Tıbbiye Street, No: 40, Uskudar, Istanbul, Turkey
| |
Collapse
|
11
|
Yiming Y, Xi C, Huan Y, Liming C, Na Y, Pei C, Ying Y, Yan L, Keming Y. Evaluation of ciliary body morphology and position of the implantable collamer lens in low-vault eyes using ultrasound biomicroscopy. J Cataract Refract Surg 2023; 49:1133-1139. [PMID: 37586102 DOI: 10.1097/j.jcrs.0000000000001285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Accepted: 08/06/2023] [Indexed: 08/18/2023]
Abstract
PURPOSE To investigate the ciliary body anatomy and position of the implantable collamer lens (ICL) in low-vault eyes and analyze factors related to insufficient vault. SETTING Zhongshan Ophthalmic Center, Guangzhou, China. DESIGN Retrospective case-control observational study. METHODS In this study, 73 eyes of 73 patients with an insufficient vault (<250 μm) were matched with 73 eyes with an ideal vault (250 to 750 μm). Ultrasound biomicroscopy was used to determine the ciliary body morphology and ICL position. The biometric parameters acquired by Scheimpflug tomography were compared. The correlation between the vault and these factors was analyzed, and the least absolute shrinkage and selection operator method was used to screen the risk factors for low vault. RESULTS The low-vault group had a steeper corneal curvature, thicker lens thickness (LT), higher crystalline lens rise, and shorter axial length (AL) (all P < .005). The ciliary process length (CPL) and maximum ciliary body thickness (CBTmax) were significantly smaller, and the trabecular-ciliary angle (TCA), iris-ciliary angle (ICA), and ciliary sulcus width (CSW) were significantly greater in the low-vault eyes (all P < .005). The low-vault group had more ICL haptics below the ciliary process, and TCA, ICA, CPL, CBTmax, CSW, and haptic position were related to the postoperative vault (all P < .05). CPL, AL, and LT were identified as predictors of a low vault. CONCLUSIONS Malposition of ICL haptics behind the ciliary process is a risk factor for low vault. A shorter CPL, thicker LT, and shorter AL are significant risk factors for the postoperative low vault.
Collapse
Affiliation(s)
- Ye Yiming
- From the State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Arad T, Awiszus L, Ackermann H, Schmack I, Kohnen T. Anterior Segment Biometry in a Caucasian Population with Cataracts. Curr Eye Res 2023; 48:930-938. [PMID: 37408497 DOI: 10.1080/02713683.2023.2233119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 06/30/2023] [Indexed: 07/07/2023]
Abstract
PURPOSE To investigate biometric factors of the anterior segment of phakic eyes with cataracts. METHODS This population-based study included Caucasian patients with cataracts in the University Eye Hospital, Goethe University Frankfurt, Germany. Biometric parameters were measured using the swept-source optical coherence tomography method. Patients were grouped into intermediate stages based on decades of life. RESULTS In total, 6289 eyes of 3615 patients (age: 70.67 ± 8.42 years) were included. Age-related reductions in the anterior chamber depth (mean ± standard deviation) decreased from 3.26 ± 0.42 mm (group A: 55-59 years) to 2.94 ± 0.4 mm (group G: 85-89 years), and those in the axial length decreased from 24.37 ± 1.87 mm (group A) to 23.39 ± 1.07 mm (group G). Likewise, the white-to-white distance decreased from 12.12 ± 0.48 mm (group A) to 11.96 ± 0.47 mm (group G). Lens thickness tended to increase accordingly from 4.39 ± 0.36 µm (group A) to 4.9 ± 0.40 µm (group G). A comparison of the eyes showed no detectable lateral difference regarding the biometric parameters between the groups (axial length: p = 0.26, Rosenthal effect size = 0.03; lens thickness: p = 0.12, R = 0.03; anterior chamber depth: p = 0.63, Rosenthal effect size = 0.01). The axial length and anterior chamber depth differed significantly between sexes (r = 0.22, p < 0.0001 and r = 0.16, p < 0.0001, respectively). Multiple regression analysis of the anterior chamber depth as a function of biometry parameters as well as age and sex additionally indicated a positive correlation of anterior chamber depth with white-to-white distance (b = 0.32, p = 10-5), axial length (b = 0.10, p = 10-5), keratometry (b = 0.07, p = 10-5), and lens thickness (b=-0.05, p = 10-5) with a high effect size (Cohen f2=1.866, p = 10-5) and strong multiple correlation coefficient (Rosenthal effect size = 0.80, p = 10-5). CONCLUSIONS In the anterior segment, there are age- and sex-dependent changes in biometric parameters. In addition, changes in anterior chamber depth were noted in relation to white-to-white distance, axial length, keratometry, and lens thickness. These data should be considered in lens calculation formulas.
Collapse
Affiliation(s)
- Tschingis Arad
- Department of Ophthalmology, Goethe University, Frankfurt, Germany
| | - Lucas Awiszus
- Department of Ophthalmology, Goethe University, Frankfurt, Germany
| | - Hanns Ackermann
- Institute for Biostatistics, Goethe University, Frankfurt, Germany
| | - Ingo Schmack
- Department of Ophthalmology, Goethe University, Frankfurt, Germany
| | - Thomas Kohnen
- Department of Ophthalmology, Goethe University, Frankfurt, Germany
| |
Collapse
|
13
|
Fan S, Feng R, Liang F, Li C, Tao S, Wang M, He C, Liu X. Objective Quantification of Lens Opacity in Posterior Subcapsular Cataracts Using IOL Master 700 and CASIA-2. Am J Ophthalmol 2023; 254:203-209. [PMID: 37327960 DOI: 10.1016/j.ajo.2023.06.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 05/30/2023] [Accepted: 06/06/2023] [Indexed: 06/18/2023]
Abstract
PURPOSE To objectively quantify the lens opacity of posterior subcapsular cataracts (PSCs) using the swept-source optical coherence tomography (SS-OCT)-based devices including IOL Master 700 and CASIA-2. DESIGN Prospective cross-sectional study. METHODS A total of 101 eyes of 101 patients with PSCs were enrolled in Zhongshan Ophthalmic Center from 2021 to 2022. The IOL Master 700 and CASIA-2 were used to obtain lens images. The average posterior subcapsular density (APSD) and the maximum posterior subcapsular density (MPSD) within the pupil area (radius: 3 or 5 mm) were measured by Image J. Spearman and Pearson correlation analysis were performed to assess the associations. RESULTS APSD-3mm, APSD-5mm, MPSD-3mm, and MPSD-5mm had positive correlations with best corrected visual acuity (BCVA; r = 0.658, 0.641, 0.583, and 0.572, P < .001, respectively), all of which were higher than the correlation between LOCS-III P score and BCVA (r = 0.548, P < .001). Particularly, the APSD-3mm showed the highest correlation with BCVA. APSD could distinguish severe PSCs (LOCS-III P score ≥ 5) with an area under the receiver operating characteristic curve (AUC) of 0.836 (95% CI 0.743-0.930) for APSD-3mm and with AUC 0.758 (95% CI 0.643-0.873) for APSD-5mm, highlighting the better performance of APSD-3mm. The APSD-3mm of IOL Master 700 correlated strongly with that of CASIA-2 (r = 0.789, P < .001). CONCLUSIONS This study presented an objective method for quantifying PSCs using IOL Master 700 and CASIA-2. APSD-3mm can be used as a new accurate and objective index for the quantitative assessment of PSCs.
Collapse
Affiliation(s)
- Shuxin Fan
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Rui Feng
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Feiyan Liang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Chuang Li
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Shuya Tao
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Mingwei Wang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Chang He
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China.
| | - Xialin Liu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| |
Collapse
|
14
|
Viinikka E, Gilbert V, Speeg-Schatz C, Gaucher D. [Posterior lens dislocation in scleromalacia with microspherophakia]. J Fr Ophtalmol 2023; 46:813-814. [PMID: 37225608 DOI: 10.1016/j.jfo.2022.12.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 12/04/2022] [Accepted: 12/06/2022] [Indexed: 05/26/2023]
Affiliation(s)
- E Viinikka
- Service d'ophtalmologie du Nouvel Hôpital civil de Strasbourg, 1, place de l'Hôpital, BP 426, 67091 Strasbourg cedex, France.
| | - V Gilbert
- Service d'ophtalmologie du Nouvel Hôpital civil de Strasbourg, 1, place de l'Hôpital, BP 426, 67091 Strasbourg cedex, France
| | - C Speeg-Schatz
- Service d'ophtalmologie du Nouvel Hôpital civil de Strasbourg, 1, place de l'Hôpital, BP 426, 67091 Strasbourg cedex, France
| | - D Gaucher
- Service d'ophtalmologie du Nouvel Hôpital civil de Strasbourg, 1, place de l'Hôpital, BP 426, 67091 Strasbourg cedex, France
| |
Collapse
|
15
|
de la Hoz A, Martinez-Enriquez E, Marcos S. Estimation of Crystalline Lens Material Properties From Patient Accommodation Data and Finite Element Models. Invest Ophthalmol Vis Sci 2023; 64:31. [PMID: 37639248 PMCID: PMC10461688 DOI: 10.1167/iovs.64.11.31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 08/03/2023] [Indexed: 08/29/2023] Open
Abstract
Purpose The mechanical properties of the crystalline lens are related to its optical function of accommodation, and their changes with age are one of the potential causes for presbyopia. We estimated the mechanical parameters of the crystalline lens using quantitative optical coherence tomography (OCT) imaging and wavefront sensing data from accommodating participants and computer modeling. Methods Full-lens shape data (from quantitative swept-source OCT and eigenlens representation) and optical power data (from Hartmann-Shack wavefront sensor) were obtained from 11 participants (22-30 years old) for relaxed accommodation at infinity and -4.5 D accommodative demand. Finite element models of lens, capsular bag, zonulae, and ciliary body were constructed using measured lens geometry and literature data, assuming a 60-mN radial force. An inverse modeling scheme was used to determine the shear moduli of the nucleus and cortex of the lens, such that the simulated deformed (maximally stretched) lens matched the participant's lens at -4.5 D. Results The shear moduli of the nucleus and cortex were 1.62 ± 1.32 and 8.18 ± 5.63 kPa, on average, respectively. The shear modulus of the nucleus was lower than that of the cortex for all participants evaluated. The average of the two moduli per participant was statistically significantly correlated with age (R2 = 0.76, P = 0.0049). Conclusions In vivo imaging and mechanical modeling of the crystalline lens allow estimations of the crystalline lens' mechanical properties. Differences between nuclear and cortical moduli and their dependency with age appear to be critical in accommodative function and likely in its impairment in presbyopia.
Collapse
Affiliation(s)
- Andres de la Hoz
- Instituto de Óptica “Daza de Valdés,” Consejo Superior de Investigaciones Científicas (IO, CSIC), Madrid, Spain
| | - Eduardo Martinez-Enriquez
- Instituto de Óptica “Daza de Valdés,” Consejo Superior de Investigaciones Científicas (IO, CSIC), Madrid, Spain
| | - Susana Marcos
- Center for Visual Science, The Institute of Optics, Flaum Eye Institute, University of Rochester, New York, United States
| |
Collapse
|
16
|
Fan L, Chang Z, Xu Y, Yin X, Wang Z. The Non-uniform Distribution of Horizontal and Vertical Crystalline Lens Rise Using Optical Coherence Tomography. J Refract Surg 2023; 39:354-359. [PMID: 37162401 DOI: 10.3928/1081597x-20230207-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
PURPOSE To observe the crystalline lens rise (CLR) in horizontal and vertical orientations using anterior segment optical coherence tomography (AS-OCT). METHODS Non-invasive swept-source AS-OCT was used to measure the lens thickness, CLR, and angle-to-angle distance (ATA) in both the horizontal and vertical orientations. Anterior chamber depth (ACD) and horizontal white-to-white corneal diameter were obtained using the Pentacam HR (Oculus Optikgeräte GmbH). Axial length was obtained using the IOLMaster 700 (Carl Zeiss Meditec AG). The paired t test was used to analyze the difference in CLR between the two orientations. Pearson correlation analysis was performed to investigate the correlations between CLR and other ocular variables. RESULTS This prospective observational study comprised 99 eyes (99 patients) that underwent Visian Implantable Collamer Lens (STAAR Surgical) implantation for myopic correction. The mean CLR was 64.29 ± 168.04 and 208.09 ± 173.12 µm in the horizontal and vertical orientations, respectively. The vertical CLR (VCLR) was significantly greater than the horizontal CLR (HCLR) (P < .05). Both the HCLR and VCLR were positively correlated with lens thickness and negatively correlated with ACD (all P < .05). The difference in CLR (VCLR-HCLR) was positively correlated with the axial length and the difference in ATA between the two orientations (P < .05). CONCLUSIONS VCLR was greater than HCLR in most patients with myopia, especially in the longer eyes. This nonuniform distribution in CLR implied different placements of the iridocorneal angles in the horizontal and vertical orientations and should be considered for the selection of ICL size and placement position. [J Refract Surg. 2023;39(5):354-359.].
Collapse
|
17
|
Rohman L, Ruggeri M, Ho A, Parel JM, Manns F. Lens Thickness Microfluctuations in Young and Prepresbyopic Adults During Steady-State Accommodation. Invest Ophthalmol Vis Sci 2023; 64:12. [PMID: 36753168 PMCID: PMC9919620 DOI: 10.1167/iovs.64.2.12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 01/22/2023] [Indexed: 02/09/2023] Open
Abstract
Purpose To determine whether lens mechanical dynamics change with age and with accommodative demands. Methods Lens thickness microfluctuations were measured using a high-speed custom-built spectral domain optical coherence tomography system in five young adults (20 to 25 years old) at 0 diopters (D), 2 D, 4 D, and maximum accommodative demand and in five prepresbyopes (38 to 45 years old) under relaxed and maximal accommodation. For each state, the measurements were repeated four times during the same session. Images of the central 2-mm zone of the lens comprising 170 A-lines/frame were acquired for 10 seconds, and axial lens thickness change was measured. Lens thickness microfluctuations (µm²/Hz) were assessed by integrating the power spectrum of lens thickness microfluctuations between 0 and 4 Hz. Results The amplitude of lens microfluctuations was higher in the accommodated states than in the relaxed state in both age groups. Lens microfluctuations were higher in young adult participants than in prepresbyopes, with a significant difference in relaxed and maximally accommodated states (P = 0.04 and P = 0.04). In the young participants, the amplitude of microfluctuations reached a plateau at maximum accommodation. Conclusions Lens mechanical dynamics are both age and accommodation dependent. The decrease in lens thickness microfluctuations with age is consistent with an age-related increase in lens stiffness or decrease of the ciliary muscle displacement. The lens does not contribute to the high-frequency component of ocular dioptric microfluctuations.
Collapse
Affiliation(s)
- Leana Rohman
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida, United States
| | - Marco Ruggeri
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida, United States
| | - Arthur Ho
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida, United States
- Brien Holden Vision Institute, Sydney, New South Wales, Australia
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Jean-Marie Parel
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida, United States
- Brien Holden Vision Institute, Sydney, New South Wales, Australia
| | - Fabrice Manns
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida, United States
| |
Collapse
|
18
|
Liu G, Kang JW, Bhagavatula S, Ahn SW, So PTC, Tearney GJ, Jonas O. Bendable long graded index lens microendoscopy. Opt Express 2022; 30:36651-36664. [PMID: 36258589 PMCID: PMC9662600 DOI: 10.1364/oe.468827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 08/25/2022] [Accepted: 09/15/2022] [Indexed: 06/16/2023]
Abstract
Graded index (GRIN) lens endoscopy has broadly benefited biomedical microscopic imaging by enabling accessibility to sites not reachable by traditional benchtop microscopes. It is a long-held notion that GRIN lenses can only be used as rigid probes, which may limit their potential for certain applications. Here, we describe bendable and long-range GRIN microimaging probes for a variety of potential micro-endoscopic biomedical applications. Using a two-photon fluorescence imaging system, we have experimentally demonstrated the feasibility of three-dimensional imaging through a 500-µm-diameter and ∼11 cm long GRIN lens subject to a cantilever beam-like deflection with a minimum bend radius of ∼25 cm. Bend-induced perturbation to the field of view and resolution has also been investigated quantitatively. Our development alters the conventional notion of GRIN lenses and enables a range of innovative applications. For example, the demonstrated flexibility is highly desirable for implementation into current and emerging minimally invasive clinical procedures, including a pioneering microdevice for high-throughput cancer drug selection.
Collapse
Affiliation(s)
- Guigen Liu
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Jeon Woong Kang
- Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Sharath Bhagavatula
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Sebastian W. Ahn
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Peter T. C. So
- Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Guillermo J. Tearney
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139, USA
- Department of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Oliver Jonas
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
| |
Collapse
|
19
|
Croft MA, Peterson J, Smith C, Kiland J, Nork TM, Mcdonald JP, Katz A, Hetzel S, Lütjen-Drecoll E, Kaufman PL. Accommodative movements of the choroid in the optic nerve head region of human eyes, and their relationship to the lens. Exp Eye Res 2022; 222:109124. [PMID: 35688214 PMCID: PMC9783760 DOI: 10.1016/j.exer.2022.109124] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2021] [Revised: 04/30/2022] [Accepted: 05/18/2022] [Indexed: 12/27/2022]
Abstract
The ciliary muscle (CM) powers the accommodative response, and during accommodation the CM pulls the choroid forward in the region of the ora serrata. Our goal was to elucidate the accommodative movements of the choroid in the optic nerve region in humans and to determine whether these movements are related to changes in the lens dimensions that occur with aging, in the unaccommodated and accommodated state. Both eyes of 12 human subjects (aged 18-51 yrs) were studied. Homatropine (1 drop/5%) was used to relax the ciliary muscle (unaccommodated or "resting" eye) and pilocarpine was used to induce the maximum accommodative response (2 drops/4%) (accommodated eye). Images of the fundus and choroid were collected in the region of the optic nerve (ON) via Spectralis OCT (infrared and EDI mode), and choroidal thickness was determined. Ultrasound biomicroscopy (UBM; 50 MHz, 35 MHz) images were collected in the region of the lens/capsule and ciliary body. OCT and UBM images were collected in the resting and accommodated state. The unaccommodated choroidal thickness declined significantly with age (p = 0.0073, r = 0.73) over the entire age range of the subjects studied (18-51 years old). The choroidal thickness was significantly negatively correlated with lens thickness in the accommodated (p = 0.01) and the unaccommodated states (p = 0.005); the thicker the lens the thinner the choroid. Choroid movements around the optic nerve during accommodation were statistically significant; during accommodation the choroid both thinned and moved centrifugally (outward/away from the optic nerve head). The accommodative choroid movements did not decline significantly with age and were not correlated with accommodative amplitude. Measurement of the choroidal thickness is possible with the Spectralis OCT instrument using EDI mode and can be used to determine the accommodative changes in choroidal thickness. The choroidal thickness decreased with age and during accommodation. It may be that age-related choroidal thinning is due to changes in the geometry of the accommodative apparatus to which it is attached (i.e., ciliary muscle/lens complex) such that when the lens is thicker, the choroid is thinner. Accommodative decrease in choroidal thickness and stretch of the retina/choroid may indicate stress/strain forces in the region of the optic nerve during accommodation and may have implications for glaucoma.
Collapse
Affiliation(s)
- Mary Ann Croft
- Department of Ophthalmology and Visual Sciences, University of Wisconsin-Madison, Madison, WI, 53792, USA.
| | - John Peterson
- Diagnostic Imaging Services Lead, UCSF Health, Wayne and Gladys Valley Center for Vision, 490 Illinois St., San Francisco, CA, 94158, USA
| | - Christopher Smith
- Department of Ophthalmology and Visual Sciences, University of Wisconsin-Madison, Madison, WI, 53792, USA
| | - Julie Kiland
- Department of Ophthalmology and Visual Sciences, University of Wisconsin-Madison, Madison, WI, 53792, USA
| | - T Michael Nork
- Department of Ophthalmology and Visual Sciences, University of Wisconsin-Madison, Madison, WI, 53792, USA
| | - Jared P Mcdonald
- Department of Ophthalmology and Visual Sciences, University of Wisconsin-Madison, Madison, WI, 53792, USA
| | - Alexander Katz
- Department of Ophthalmology and Visual Sciences, University of Wisconsin-Madison, Madison, WI, 53792, USA
| | - Scott Hetzel
- Department of Biostatistics and Medical Informatics, University of Wisconsin-Madison, Madison, USA
| | | | - Paul L Kaufman
- Department of Ophthalmology and Visual Sciences, University of Wisconsin-Madison, Madison, WI, 53792, USA; Wisconsin National Primate Research Center, USA
| |
Collapse
|
20
|
Williamson Iii JE, Bas Z, Shields CL. Angiography of Florid Tunica Vasculosa Lentis in Persistent Fetal Vasculature. J Pediatr Ophthalmol Strabismus 2022; 59:204. [PMID: 34928764 DOI: 10.3928/01913913-20210921-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
21
|
Avetisov SE, Shitikova AV, Avetisov KS. [Anatomical, morphological and biomechanical aspects of accommodation]. Vestn Oftalmol 2022; 138:117-125. [PMID: 36004600 DOI: 10.17116/oftalma2022138041117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The article reviews the findings on the anatomy, morphological and biomechanical features of the accommodation apparatus. Modern methods of imaging and biometry confirm the validity of the Helmholtz lenticular theory of accommodation, according to which its mechanism involves three main components: the ciliary body, the zonular fibres and the lens capsule, the lens itself. Based on this, there is certain interest in studying the degree of participation of each of these components in the development of age-related changes in accommodation (presbyopia).
Collapse
Affiliation(s)
- S E Avetisov
- Research Institute of Eye Disease, Moscow, Russia
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | | | - K S Avetisov
- Research Institute of Eye Disease, Moscow, Russia
| |
Collapse
|
22
|
He N, Lv Z. A rare asymptomatic metallic intraocular foreign body retained in the anterior chamber for 15 years: A case report. Medicine (Baltimore) 2021; 100:e26470. [PMID: 34160455 PMCID: PMC8238337 DOI: 10.1097/md.0000000000026470] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Accepted: 06/07/2021] [Indexed: 01/04/2023] Open
Abstract
RATIONALE Intraocular foreign bodies (IOFBs) are common in ocular injuries, but asymptomatic metallic IOFBs retained in the anterior chamber for years are rare. PATIENT CONCERNS A 31-year-old female presented with blurred vision in her right eye after lumbar magnetic resonance imaging. Her best-corrected vision acuity was 0.6 in the right eye and 1.0 in the left eye. Slit-lamp examination revealed a brown granular foreign body in the anterior chamber and pigmentation of the limbus. Lens and retina examination indicated ocular siderosis. Corneal endothelioscopy revealed decreased endothelial cell density. A detailed history showed ocular globe injury 15 years earlier. DIAGNOSES Anterior chamber IOFB with ocular siderosis. INTERVENTIONS Anterior chamber foreign body removal was performed with appropriate incision and forceps. OUTCOMES The anterior chamber IOFB was successfully removed and examined as a magnetic metal foreign body. The best-corrected vision acuity was 1.0 at 1 day postoperatively. An abnormal electroretinogram with a 12% decrease in the "b" wave and a 91% decrease in the "a" wave was observed 3 months postoperatively. There were no intraoperative or postoperative complications during a 3-month follow-up. LESSONS Eye trauma should be examined carefully to exclude IOFBs. Asymptomatic anterior chamber foreign bodies can also cause corneal endothelial injury and ocular siderosis. Careful examination and timely management are needed in such cases.
Collapse
|
23
|
Taechameekietichai T, Nguyen A, Chansangpetch S, Lin SC. Displacement between anterior chamber width obtained by swept-source anterior segment optical coherence tomography and white-to-white distance. PLoS One 2021; 16:e0251990. [PMID: 34015039 PMCID: PMC8136703 DOI: 10.1371/journal.pone.0251990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Accepted: 05/06/2021] [Indexed: 11/18/2022] Open
Abstract
Purpose To determine the relationship between the external limbal location, represented by white-to-white (WTW) distance, and the actual angle location, represented by spur-to-spur (STS) and angle-to-angle (ATA) distances. Methods 166 eyes from 166 participants were imaged using CASIA2 anterior chamber optical coherence tomography (AS-OCT) and LenStar LS 900 optical biometer. The horizontal ATA and STS were measured using the swept-source Fourier-domain AS-OCT (CASIA2). The horizontal WTW was automatically measured using LenStar. The displacement lengths (DL) between WTW-STS and WTW-ATA were calculated. Bland-Altman plots and intraclass correlation were performed. Results The study showed that WTW has a positive correlation with STS (ICC = 0.82, p<0.001) and ATA (ICC = 0.82, p<0.001). The Bland-Altman analysis demonstrated that the mean difference of WTW-STS is 0.10 mm (95% CI 0.06 to 0.14 mm) with limits of agreement of -0.42 to 0.63 mm between WTW and STS, and the mean difference of WTW-ATA is 0.10 mm (95% CI 0.06 to 0.15 mm) with limits of agreement of -0.48 to 0.64 mm between WTW and ATA. Linear regression with adjustment showed that a WTW value greater than 12.07 mm is associated with a greater DL (WTW-STS DL ß 0.18, p = 0.003; WTW-ATA DL ß 0.14, p = 0.03). Conclusions Greater WTW was significantly associated with higher displacement of WTW from the two distances representing anterior chamber width. External limbal location may not accurately represent the actual angle location in eyes with larger WTW.
Collapse
Affiliation(s)
| | - Anwell Nguyen
- Department of Ophthalmology, University of California, San Francisco, San Francisco, California, United States of America
| | - Sunee Chansangpetch
- Department of Ophthalmology, University of California, San Francisco, San Francisco, California, United States of America
- Glaucoma Research Unit, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand
- * E-mail:
| | - Shan C. Lin
- Department of Ophthalmology, University of California, San Francisco, San Francisco, California, United States of America
- Glaucoma Center of San Francisco, San Francisco, California, United States of America
| |
Collapse
|
24
|
Waring GO, Chang DH, Rocha KM, Gouvea L, Penatti R. Correlation of Intraoperative Optical Coherence Tomography of Crystalline Lens Diameter, Thickness, and Volume with Biometry and Age. Am J Ophthalmol 2021; 225:147-156. [PMID: 33385370 DOI: 10.1016/j.ajo.2020.12.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Revised: 09/30/2020] [Accepted: 12/17/2020] [Indexed: 12/12/2022]
Abstract
PURPOSE To characterize crystalline lens dimensions derived from in vivo spectral-domain optical coherence tomography (SD-OCT) and identify associations among these parameters, ocular biometry, and age. METHODS In this retrospective study, lens thickness (LT), lens diameter (LD), and lens volume (LV) were measured intraoperatively using SD-OCT in 293 eyes undergoing lens surgery. Correlations among LT, LD, LV, age, axial length (AL), and anterior chamber depth (ACD) were analyzed. Multiple regression analysis was performed to determine whether a combination of biometric data could predict LD and LV. RESULTS Wide variations were observed in LT (3.6-5.7 mm), LD (7.5-11.9 mm), and LV (119.9-312.4 mm3) of aging eyes. Correlations among the 3 lens dimensions were statistically significant (LV-LT: r = 0.785; P < .001; LV-LD: r = 0.696; P < .001; and LT-LD: r = 0.121; P = .039). With age, the correlation coefficients of LT, LD, and LV were 0.526, 0.326, and 0.573, respectively (P < .001). Although there was significant correlation of AL with LT (r = -0.137; P = .002) and LD (r = 0.268; P < .001), it was not significant with LV (r = 0.084; P = .15). Subgroup analysis revealed that 19.8% of long eyes had LD >1 standard deviation (SD) above and that 5.2% had LD <1 SD below the mean LD. CONCLUSIONS Dimensions of the aging lens vary considerably and are most accurately characterized by direct measurement of LT, LD, and LV, rather than making assumptions based on AL. These findings challenge historically proposed relationships between LD and AL and represent a normative dataset of contemporary geometric features of the aging lens, possibly aiding in surgical decision making and future developments in lens surgery.
Collapse
Affiliation(s)
| | - Daniel H Chang
- Empire Eye and Laser Center, Bakersfield, California, USA
| | - Karolinne Maia Rocha
- Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Larissa Gouvea
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada
| | | |
Collapse
|
25
|
Le C, Baroni M, Vinnett A, Levin MR, Martinez C, Jaafar M, Madigan WP, Alexander JL. Deep Learning Model for Accurate Automatic Determination of Phakic Status in Pediatric and Adult Ultrasound Biomicroscopy Images. Transl Vis Sci Technol 2020; 9:63. [PMID: 33409005 PMCID: PMC7779873 DOI: 10.1167/tvst.9.2.63] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 11/06/2020] [Indexed: 12/31/2022] Open
Abstract
Purpose Ultrasound biomicroscopy (UBM) is a noninvasive method for assessing anterior segment anatomy. Previous studies were prone to intergrader variability, lacked assessment of the lens-iris diaphragm, and excluded pediatric subjects. Lens status classification is an objective task applicable in pediatric and adult populations. We developed and validated a neural network to classify lens status from UBM images. Methods Two hundred eighty-five UBM images were collected in the Pediatric Anterior Segment Imaging Innovation Study (PASIIS) from 80 eyes of 51 pediatric and adult subjects (median age = 4.6 years, range = 3 weeks to 90 years) with lens status phakic, aphakic, or pseudophakic (n = 33, 7, and 21 subjects, respectively). Following transfer learning, a pretrained Densenet-121 model was fine-tuned on these images. Metrics were calculated for testing dataset results aggregated from fivefold cross-validation. For each fold, 20% of total subjects were partitioned for testing and the remaining subjects were used for training and validation (80:20 split). Results Our neural network trained across 60 epochs achieved recall 96.15%, precision 96.14%, F1-score 96.14%, false positive rate 3.74%, and area under the curve (AUC) 0.992. Feature saliency heatmaps consistently involved the lens. Algorithm performance was compared using 2 image sets, 1 from subjects of all ages, and the second from only subjects under age 10 years, with similar performance under both circumstances. Conclusions A neural network trained on a relatively small UBM image set classified lens status with satisfactory recall and precision. Adult and pediatric image sets offered roughly equivalent performance. Future studies will explore automated UBM image classification for complex anterior segment pathology. Translational Relevance Deep learning models can evaluate lens status from UBM images in adult and pediatric subjects using a limited image set.
Collapse
Affiliation(s)
- Christopher Le
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Mariana Baroni
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Alfred Vinnett
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Moran R Levin
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Camilo Martinez
- Department of Ophthalmology, Children's National Medical System, Washington, DC, USA
| | - Mohamad Jaafar
- Department of Ophthalmology, Children's National Medical System, Washington, DC, USA
| | - William P Madigan
- Department of Ophthalmology, Children's National Medical System, Washington, DC, USA
| | - Janet L Alexander
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD, USA
| |
Collapse
|
26
|
Kumawat D, Sahay P, Chawla R, Venkatraman V, Venkatesh P, Khokhar S. Clinical Features of Nontraumatic Posterior Dislocation of Crystalline Lens. Ophthalmol Retina 2020; 4:545-547. [PMID: 32063516 DOI: 10.1016/j.oret.2019.12.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 12/18/2019] [Accepted: 12/18/2019] [Indexed: 11/19/2022]
Affiliation(s)
- Devesh Kumawat
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Pranita Sahay
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Rohan Chawla
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
| | - Vatsalya Venkatraman
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Pradeep Venkatesh
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Sudarshan Khokhar
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
27
|
Pirchio R, Stefanic A, Rojas RR. CHARACTERISATION OF TLDS-200 AND OSLDS AT LOW X-RAY ENERGIES AND DETERMINATION OF EYE LENS DOSE, THYROID DOSE AND MEAN GLANDULAR DOSE DURING STANDARD MAMMOGRAPHY AND TOMOSYNTHESIS. Radiat Prot Dosimetry 2019; 186:469-478. [PMID: 31329992 DOI: 10.1093/rpd/ncz052] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Revised: 03/13/2019] [Accepted: 03/26/2019] [Indexed: 06/10/2023]
Abstract
The objective of this study was to characterise thermoluminescent (TLDs) and optically stimulated luminescent dosimeters (OSLDs) at low X-ray energies and estimate the eye lens (DL), thyroid (DT) and mean glandular (DG) doses received during Full-Field Digital Mammography (FFDM) and Digital Breast Tomosynthesis (DBT). The dosimeters were characterised in mammography energies. DL, DT and DG were estimated in FFDM and DBT mode taping dosimeters on the skin of the thyroid gland and on the left eye lens of an Alderson phantom. Dosimeters were also placed on the top of a NORMI PAS phantom simulating a compressed breast. The accuracy, precision and lower limit of detection (LLD) for TLDs and OSLDs were 5 and 8%, 6 and 3%, and 38 and 11 μSv, respectively. The linearity of the kerma response had an R2 > 0.99 and energy dependence was lower than 40%. DT ranged from 0.40 to 2.87 μGy for FFDM and 1.27 to 5.99 μGy for DBT. DG was between 0.50 and 1.27 mGy for FFDM and 1.07 and 1.60 mGy for DBT. DL was below the LLD. Dosimeters showed good performance. DG values were lower than those found in the literature, whereas DT value agreed with references. Differences between DG and DT determined with OSLDs and TLDs were lower than 10% and 200%.
Collapse
Affiliation(s)
- R Pirchio
- Comisión Nacional de Energía Atómica, Av. Pro González y Aragón 15, B1802AYA, Ezeiza, Buenos Aires, Argentina
| | - A Stefanic
- Comisión Nacional de Energía Atómica, Av. Pro González y Aragón 15, B1802AYA, Ezeiza, Buenos Aires, Argentina
| | - R R Rojas
- Centro de Diagnóstico Rojas, Laprida 1810, C1425EKP, CABA, Buenos Aires, Argentina
| |
Collapse
|
28
|
Beşek NK, Tülü Aygün B, Yıldız BK, Er MO, Yıldırım Y, Genç S, Ağca A. Intraocular lens opacification following Triple-Descemet membrane endothelial keratoplasty surgery. J Fr Ophtalmol 2019; 43:e7-e10. [PMID: 31831275 DOI: 10.1016/j.jfo.2019.06.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 06/19/2019] [Accepted: 06/20/2019] [Indexed: 11/19/2022]
Affiliation(s)
- N K Beşek
- University of Health Sciences, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey.
| | - B Tülü Aygün
- University of Health Sciences, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey
| | - B K Yıldız
- University of Health Sciences, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey
| | - M O Er
- University of Health Sciences, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey
| | - Y Yıldırım
- University of Health Sciences, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey
| | - S Genç
- University of Health Sciences, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey
| | - A Ağca
- University of Health Sciences, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey
| |
Collapse
|
29
|
Yoo YS, Whang WJ, Kim HS, Joo CK, Yoon G. Preoperative biometric measurements with anterior segment optical coherence tomography and prediction of postoperative intraocular lens position. Medicine (Baltimore) 2019; 98:e18026. [PMID: 31852065 PMCID: PMC6922509 DOI: 10.1097/md.0000000000018026] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
The purpose of this study is to evaluate the biometric parameters of crystalline lens components and to find effective factors for predicting postoperative intraocular lens (IOL) position. This retrospective study included 97 eyes from 97 patients with a mean age of 63.00 ± 12.38 (SD) years. The biometric measurements were performed by means of a 3-dimensional optical coherence tomography (3D-OCT) device. Specifically, anterior chamber depth (ACD), aqueous depth (AD), lens thickness (LT), lens meridian parameter (LMP), white-to-white diameters (WTW), anterior segment length (ASL), the anterior part of lens (aLT), and the posterior part of lens (pLT) were measured. Additionally, axial length (AL) and corneal radius (CR) were measured by the partial coherence interferometry. Ninety-seven eyes were divided into thin lens group (LT < 4.5 mm) and thick lens group (LT ≥ 4.5 mm). The differences between the above two groups were also analyzed. Postoperative IOL position was measured by 3D-OCT at 3 months postoperatively and regression formulas for predicting postoperative IOL position were developed by various combinations of preoperative factors. As lens thickened, ACD and AD became shallow (all P < .001). AD, ACD, ASL, aLT, and pLT showed statistically significant differences between two subgroups classified on the basis of LT (all P < .001). Meanwhile, the value obtained by subtracting aLT from pLT did not show any association with the other biometric measurements. The combination of ACD, aLT, pLT, AL, CR, and WTW showed the highest correlation with postoperative IOL position (R = 0.536, P < .001). In conclusion, pLT-aLT was an independent factor not affected by any other variables and did not show significant difference between thin lens group and thick lens group. The subdivision of the lens structure using 3D-OCT helps to predict postoperative IOL position.
Collapse
Affiliation(s)
- Young-Sik Yoo
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine
| | - Woong-Joo Whang
- Department of Ophthalmology, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea
| | - Hyun-Seung Kim
- Department of Ophthalmology, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea
| | | | - Geunyoung Yoon
- Flaum Eye Institute, The Institute of Optics, Center for Visual Science, University of Rochester, Rochester, New York, USA
| |
Collapse
|
30
|
Kawauchi S, Chida K, Moritake T, Matsumaru Y, Hamada Y, Sakuma H, Yoda S, Sun L, Sato M, Tsuruta W. ESTIMATION OF PATIENT LENS DOSE ASSOCIATED WITH C-ARM CONE-BEAM COMPUTED TOMOGRAPHY USAGE DURING INTERVENTIONAL NEURORADIOLOGY. Radiat Prot Dosimetry 2019; 184:138-147. [PMID: 30452704 DOI: 10.1093/rpd/ncy188] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Revised: 09/05/2018] [Accepted: 10/13/2018] [Indexed: 06/09/2023]
Abstract
The purpose of this study was to investigate the dose distribution and lens doses associated with C-arm cone-beam computed tomography (CBCT), using a head phantom, and to estimate the contribution ratio of C-arm CBCT to each patient's lens dose during interventional neuroradiology ('lens dose ratio') in 109 clinical cases. In the phantom study, the peak skin doses and respective right and left lens doses of C-arm CBCT were as follows: 63.0 ± 1.9 mGy, 19.7 ± 1.4 mGy and 21.9 ± 0.8 mGy in whole brain C-arm CBCT and 39.2 ± 1.4 mGy, 4.7 ± 0.9 mGy and 3.6 ± 0.3 mGy in high-resolution C-arm CBCT. In the clinical study, the lens dose ratios were 25.4 ± 8.7% in the right lens and 19.1 ± 9.8% in the left lens. This study shows that, on average, ~25% of patients' total lens dose was contributed by C-arm CBCT.
Collapse
Affiliation(s)
- Satoru Kawauchi
- Department of Radiology, Toranomon Hospital, 2-2-2 Toranomon, Minato, Tokyo, Japan
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba, Sendai, Miyagi, Japan
| | - Koichi Chida
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba, Sendai, Miyagi, Japan
| | - Takashi Moritake
- Department of Radiological Health Science, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, 1-1, Iseigaoka, Yahatanishi, Kitakyushu, Fukuoka, Japan
| | - Yuji Matsumaru
- Division for Stroke Prevention and Treatment, Department of Neurosurgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, Japan
| | - Yusuke Hamada
- Department of Radiology, Toranomon Hospital, 2-2-2 Toranomon, Minato, Tokyo, Japan
| | - Hideyuki Sakuma
- Department of Radiology, Toranomon Hospital, 2-2-2 Toranomon, Minato, Tokyo, Japan
| | - Shogo Yoda
- Department of Radiology, Toranomon Hospital, 2-2-2 Toranomon, Minato, Tokyo, Japan
| | - Lue Sun
- Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, Japan
| | - Masayuki Sato
- Division for Stroke Prevention and Treatment, Department of Neurosurgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, Japan
| | - Wataro Tsuruta
- Department of Endovascular Neurosurgery, Toranomon Hospital, 2-2-2 Toranomon, Minato, Tokyo, Japan
| |
Collapse
|
31
|
Abstract
Brillouin spectroscopy and imaging are emerging techniques in analytical science, biophotonics, and biomedicine. They are based on Brillouin light scattering from acoustic waves or phonons in the GHz range, providing a nondestructive contactless probe of the mechanics on a microscale. Novel approaches and applications of these techniques to the field of biomedical sciences are discussed, highlighting the theoretical foundations and experimental methods that have been developed to date. Acknowledging that this is a fast moving field, a comprehensive account of the relevant literature is critically assessed here.
Collapse
Affiliation(s)
- Francesca Palombo
- School
of Physics and Astronomy, University of
Exeter, Stocker Road, EX4 4QL Exeter, U.K.
| | - Daniele Fioretto
- Department
of Physics and Geology, University of Perugia, via Alessandro Pascoli, I-06123 Perugia, Italy
| |
Collapse
|
32
|
Safi M, Nejad SK, O'Hara M, Shankar SP. Ectopia Lentis et Pupillae Caused by ADAMTSL4 Pathogenic Variants and an Algorithm for Work-up. J Pediatr Ophthalmol Strabismus 2019; 56:e45-e48. [PMID: 31282960 DOI: 10.3928/01913913-20190509-01] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Accepted: 03/26/2019] [Indexed: 11/20/2022]
Abstract
Ectopia lentis is displacement of the lens from its original position. It can be inherited or acquired with isolated or systemic findings. The authors describe a 4-year-old girl with isolated ectopia lentis et pupillae caused by pathogenic variants in the ADAMTSL4 gene and discuss the molecular genetic work-up of individuals with ectopia lentis. [J Pediatr Ophthalmol Strabismus. 2019;56:e45-e48.].
Collapse
|
33
|
Vanathi M, Kumawat D, Singh R, Chandra P. Iatrogenic Crystalline Lens Injury in Pediatric Eyes Following Intravitreal Injection for Retinopathy of Prematurity. J Pediatr Ophthalmol Strabismus 2019; 56:162-167. [PMID: 31116863 DOI: 10.3928/01913913-20190211-02] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Accepted: 01/24/2019] [Indexed: 11/20/2022]
Abstract
PURPOSE To report the occurrence of lens injury during intravitreal anti-vascular endothelial growth factor (anti-VEGF) injection in infants with retinopathy of prematurity (ROP). METHODS ROP cases presenting to a tertiary care center with cataract following intravitreal injection were retrospectively studied from June 2017 to May 2018. The indication, setting, and method of injection were noted. Ultrasound biomicroscopy (UBM) details were recorded. The main measures were morphology of cataract, posterior capsular defect, and intraocular lens (IOL) placement. RESULTS Three children (mean age: 14 ± 8.6 months, two male and one female) received injection elsewhere under topical anesthesia in the neonatal intensive care unit (NICU) for type 1 ROP (stage 3 in zone I or II with significant plus disease) 9 to 18 months earlier. All cases developed cataract caused by intravitreal needle damaging the posterior capsule. In one case, a dense zonular cataract was present and peripheral dehiscence of the posterior capsule became evident only during lens aspiration. The second and third cases had a central posterior subcapsular cataract. Preexisting central dehiscence of the posterior capsule was noted on UBM and confirmed during surgery. A multi-piece IOL was securely placed in all cases. At last follow-up (median: 6 months; range: 3 to 6 months), the IOL was stable and centered in all cases with a clear visual axis. CONCLUSIONS The increasing occurrence of cataract in treatment-requiring ROP following intravitreal anti-VEGF injections being given by practitioners in the NICU setting under topical anesthesia that hinders optimal visualization and technique is a significant concern. [J Pediatr Ophthalmol Strabismus. 2019;56(3):162-167.].
Collapse
|
34
|
Pérez Dieste JM, Castroviejo Bolíbar M, Sánchez Servate C, Gargallo García M. Posterior lenticonus in Scheimpflug images. Arch Soc Esp Oftalmol (Engl Ed) 2019; 94:e29-e30. [PMID: 30718013 DOI: 10.1016/j.oftal.2018.11.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 11/25/2018] [Indexed: 06/09/2023]
Affiliation(s)
- J M Pérez Dieste
- Servicio de Oftalmología, Hospital Quirónsalud Costa Adeje, Santa Cruz de Tenerife, Islas Canarias, España.
| | - M Castroviejo Bolíbar
- Servicio de Oftalmología, Complejo Hospitalario Universitario, Santiago de Compostela, La Coruña, España
| | - C Sánchez Servate
- Servicio de Oftalmología, Hospital Quirónsalud Costa Adeje, Santa Cruz de Tenerife, Islas Canarias, España
| | - M Gargallo García
- Servicio de Oftalmología, Hospital Quirónsalud Tenerife, Santa Cruz de Tenerife, Islas Canarias, España
| |
Collapse
|
35
|
Zhang H, Wu C, Singh M, Nair A, Aglyamov SR, Larin KV. Optical coherence elastography of cold cataract in porcine lens. J Biomed Opt 2019; 24:1-7. [PMID: 30864348 PMCID: PMC6444576 DOI: 10.1117/1.jbo.24.3.036004] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Accepted: 02/19/2019] [Indexed: 05/08/2023]
Abstract
Cataract is one of the most prevalent causes of blindness around the world. Understanding the mechanisms of cataract development and progression is important for clinical diagnosis and treatment. Cold cataract has proven to be a robust model for cataract formation that can be easily controlled in the laboratory. There is evidence that the biomechanical properties of the lens can be significantly changed by cataract. Therefore, early detection of cataract, as well as evaluation of therapies, could be guided by characterization of lenticular biomechanical properties. In this work, we utilized optical coherence elastography (OCE) to monitor the changes in biomechanical properties of ex vivo porcine lenses during formation of cold cataract. Elastic waves were induced in the porcine lenses by a focused micro air-pulse while the lenses were cooled, and the elastic wave velocity was translated to Young's modulus of the lens. The results show an increase in the stiffness of the lens due to formation of the cold cataract (from 11.3 ± 3.4 to 21.8 ± 7.8 kPa). These results show a relation between lens opacity and stiffness and demonstrate that OCE can assess lenticular biomechanical properties and may be useful for detecting and potentially characterizing cataracts.
Collapse
Affiliation(s)
- Hongqiu Zhang
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Chen Wu
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Manmohan Singh
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Achuth Nair
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
| | - Salavat R. Aglyamov
- University of Houston, Department of Mechanical Engineering, Houston, Texas, United States
- University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States
| | - Kirill V. Larin
- University of Houston, Department of Biomedical Engineering, Houston, Texas, United States
- Address all correspondence to Kirill V. Larin, E-mail:
| |
Collapse
|
36
|
Peng J, Jia X, Wang J, Hu Y. [A Simplifed Model Eye for Testing Fundus Imaging Device]. Zhongguo Yi Liao Qi Xie Za Zhi 2019; 43:21-24. [PMID: 30770685 DOI: 10.3969/j.issn.1671-7104.2019.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Based on the Gullstrand I model eye, a simplified model eye for testing fundus imaging device is designed. The model eye can reach the following requirements:(1) The refractive characteristics of the ocular refractive tissue are simulated, and the equivalent focal length in air is 17 mm; (2) The differences between relative refractive index differences of the adjacent materials of the simplified model eye and relative refractive index differences of any adjacent two layers (cornea and aqueous humor, aqueous humor and lens, lens and vitreous body) of the Gullstrand I model eye are not more than 1%; (3) In the case of the incident aperture diameter of 3 mm, the differences of radii of the diffuse spots formed by the paraxial light and the axial light are not more than 15%; (4) The differences of angles of chief ray and tangent line of the fundus are not more than 1°; (5) In the case of the incident aperture diameter of 3 mm, the differences of MTF values of the near axis light are not more than 0.1. The simplified model eye can be expected to be used for testing fundus imaging device instead of the test method in ISO 10940:2009 Ophthalmic instruments-Fundus cameras.
Collapse
Affiliation(s)
- Jianhua Peng
- Zhejiang Institute of Medical Device Testing, Hangzhou, 310018
| | - Xiaohang Jia
- Zhejiang Institute of Medical Device Testing, Hangzhou, 310018
| | - Jingtao Wang
- Zhejiang Institute of Medical Device Testing, Hangzhou, 310018
| | - Yiping Hu
- Zhejiang Institute of Medical Device Testing, Hangzhou, 310018
| |
Collapse
|
37
|
Seth NG, Thattaruthody F, Pandav SS. Vossius Ring after Blunt Ophthalmic Trauma. Ophthalmol Glaucoma 2019; 2:54. [PMID: 32672558 DOI: 10.1016/j.ogla.2018.10.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Revised: 10/12/2018] [Accepted: 10/18/2018] [Indexed: 11/18/2022]
Affiliation(s)
- Natasha Gautam Seth
- Advanced Eye Center, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Faisal Thattaruthody
- Advanced Eye Center, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Surinder Singh Pandav
- Advanced Eye Center, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| |
Collapse
|
38
|
Gonzalez A, Agarwal-Sinha S, Iyer SSR, Bolling JP. Multiloculated Ciliary Body Cysts and Lenticular Coloboma: A Rare Phenotypic Variation Associated With Persistent Fetal Vasculature. J Pediatr Ophthalmol Strabismus 2018; 55:e39-e41. [PMID: 30388281 DOI: 10.3928/01913913-20181010-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Accepted: 08/03/2018] [Indexed: 11/20/2022]
Abstract
A case of a 4 year-old boy with persistent fetal vasculature, lenticular coloboma, and a benign, multiloculated ciliary body mass is reviewed. The presence of ciliary body cysts in association with persistent fetal vasculature is sparsely reported. Its presence in a child can cause a diagnostic dilemma and lead to amblyopia. [J Pediatr Ophthalmol Strabismus. 2018;55:e39-e41.].
Collapse
|
39
|
Wang L, Guimaraes de Souza R, Weikert MP, Koch DD. Evaluation of crystalline lens and intraocular lens tilt using a swept-source optical coherence tomography biometer. J Cataract Refract Surg 2018; 45:35-40. [PMID: 30309775 DOI: 10.1016/j.jcrs.2018.08.025] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 08/06/2018] [Accepted: 08/09/2018] [Indexed: 01/19/2023]
Abstract
PURPOSE To evaluate crystalline lens and intraocular lens (IOL) tilt using a swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700). SETTING Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. DESIGN Retrospective case series. METHODS The study patients were evaluated for 1) repeatability of the crystalline lens tilt measurement, 2) preoperative crystalline lens and postoperative IOL tilt in right eyes, 3) mirror symmetry between right eyes and left eyes, 4) the correlation between preoperative crystalline lens and postoperative IOL tilt, and 5) the correlation between the magnitude of lens tilt and ocular parameters. RESULTS The study comprised 333 patients. The repeatability was 0.1 degrees for tilt magnitude and 3.0 degrees for tilt direction. Both the crystalline lens and IOL had anterior tilt of the nasal portion with mean tilt magnitudes of 3.7 degrees ± 1.1 (SD) (range 0.4 to 6.9 degrees) for the crystalline lens and 4.9 ± 1.8 degrees (range 1.6 to 10.7 degrees) for the IOL. There was mirror symmetry between right eyes and left eyes. The mean IOL tilt magnitude exceeded crystalline lens tilt by 1.2 ± 1.1 degrees (range -3.2 to 4.0 degrees), and the 2 values were significantly correlated (all P < .01). The magnitude of crystalline lens tilt significantly increased with decreasing axial length and with increasing angle α (all P < .05). CONCLUSIONS The repeatability of crystalline lens tilt measurements using the SS-OCT biometer was excellent. There was mirror symmetry between the right eyes and left eyes. Preoperative crystalline lens tilt could be used to predict the postoperative IOL tilt. The lens tilt magnitude was greater in short eyes and in eyes with larger angle α.
Collapse
Affiliation(s)
- Li Wang
- Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA
| | | | | | - Douglas D Koch
- Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA.
| |
Collapse
|
40
|
Rossin EJ, VanderVeen DK, Yonekawa Y. Bilateral Immediate Sequential Vitrectomy and Lensectomy for Bilateral Lens Dislocation in Severe Neonatal Marfan Syndrome. Ophthalmic Surg Lasers Imaging Retina 2018; 49:e151-e153. [PMID: 30395677 DOI: 10.3928/23258160-20181002-19] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2018] [Accepted: 02/28/2018] [Indexed: 11/20/2022]
Abstract
A newborn with severe neonatal Marfan syndrome (NMS), characterized by aortic root dilation, mitral and tricuspid valve regurgitation, diaphragmatic eventration with respiratory distress, intestinal malrotation, and various skeletal abnormalities, developed bilateral pupillary block from luxated crystalline lenses. He underwent bilateral immediate sequential vitrectomy and lensectomy to prevent further episodes of pupillary block. Bilateral surgery was performed due to the extremely high anesthesia risk. NMS is a rare and severe form of the connective tissue disease that can present with numerous systemic and ocular findings. Measures to decrease anesthesia risk are recommended, including the consideration of bilateral surgery. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:e151-e153.].
Collapse
|
41
|
Moghimi S, Torkashvand A, Mohammadi M, Yaseri M, Saunders LJ, Lin SC, Weinreb RN. Classification of primary angle closure spectrum with hierarchical cluster analysis. PLoS One 2018; 13:e0199157. [PMID: 30036362 PMCID: PMC6056027 DOI: 10.1371/journal.pone.0199157] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 06/02/2018] [Indexed: 11/19/2022] Open
Abstract
PURPOSE To classify subjects with primary angle closure into clusters based on features from anterior segment optical coherence tomography (ASOCT) imaging and to explore how these clusters correspond to disease subtypes, including primary angle closure suspect (PACS), primary angle closure glaucoma(PACG), acute primary angle closure (APAC) and fellow eyes of APAC and reveal the factors that become more predominant in each subtype of angle closure. METHOD A cross-sectional study of 248 eyes of 198 subjects(88 PACS eyes, 53 PACG eyes, 54 APAC eyes and 53 fellow eyes of APAC) that underwent complete examination including gonioscopy, A-scan biometry, and ASOCT. An agglomerative hierarchical clustering method was used to classify eyes based on ASOCT parameters. RESULTS Statistical clustering analysis produced three clusters among which the anterior segment parameters were significantly different. Cluster 1(43 eyes) had the smallest anterior chamber depth(ACD) and area, as well as the greatest lens vault (p<0.001 for all). Cluster 2(113 eyes) had the thickest iris at 2000 microns(p = 0.048), and largest iris area(p<0.001), and the deepest ACD (p<0.001). Cluster 3(92 eyes) was characterized by elements of both clusters 1 and 2 and a higher iris curvature(p<0.001). There was a statistically significant difference in the distribution of clusters among subtypes of angle closure eyes(p<0.001). Although the patterns of clusters were similar in PACS and PACG eyes, with the majority of the eyes classified into cluster 2(55%, and 62%, respectively), the highest proportion of APAC and fellow eyes were assigned to clusters 1(44%) and 3 (51%), respectively. CONCLUSION Hierarchical cluster analysis identified three clusters with different features. Predominant anatomical components are different among subtypes of primary angle closure.
Collapse
Affiliation(s)
- Sasan Moghimi
- Hamilton Glaucoma Center, Department of Ophthalmology, Shiley Eye Institute, University of California-San Diego, La Jolla, California, United States of America
- Department of Ophthalmology, Shiley Eye Institute, University of California, San Diego, La Jolla, California, United States of America
- Tehran University Research Center, Tehran University of Medical Science, Tehran, Iran
| | - Ali Torkashvand
- Tehran University Research Center, Tehran University of Medical Science, Tehran, Iran
| | - Massood Mohammadi
- Tehran University Research Center, Tehran University of Medical Science, Tehran, Iran
| | - Mehdi Yaseri
- Department of Epidemiology and Biostatistics, Tehran University of Medical Sciences, Tehran, Iran
| | - Luke J. Saunders
- Hamilton Glaucoma Center, Department of Ophthalmology, Shiley Eye Institute, University of California-San Diego, La Jolla, California, United States of America
| | - Shan C. Lin
- Koret Vision Center, University of California, San Francisco Medical School, San Francisco, California, United States of America
| | - Robert N. Weinreb
- Hamilton Glaucoma Center, Department of Ophthalmology, Shiley Eye Institute, University of California-San Diego, La Jolla, California, United States of America
- Department of Ophthalmology, Shiley Eye Institute, University of California, San Diego, La Jolla, California, United States of America
- * E-mail:
| |
Collapse
|
42
|
Batista A, Breunig HG, König A, Morgado AM, König K. Assessment of the metabolism and morphology of the porcine cornea, lens and retina by 2-photon imaging. J Biophotonics 2018; 11:e201700324. [PMID: 29575612 DOI: 10.1002/jbio.201700324] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Accepted: 03/21/2018] [Indexed: 06/08/2023]
Abstract
Two-photon imaging is a noninvasive imaging technique with increasing importance in the biological and medical fields since it allows intratissue cell imaging with high resolution. We demonstrate the feasibility of using a single 2-photon instrument to evaluate the cornea, the crystalline lens and the retina based on their autofluorescence (AF). Image acquisition was performed using a custom-built 2-photon microscope for 5-dimensional microscopy with a near infrared broadband sub-15 femtosecond laser centered at 800 nanometers. Signals were detected using a spectral photomultiplier tube. The spectral ranges for the analysis of each tissue/layer AF were determined based on the spectra of each tissue as well as of pure endogenous fluorophores. The cornea, lens and retina are characterized at multiple depths with subcellular resolution based on their morphology and AF lifetime. Additionally, the AF lifetime of NAD(P)H was used to assess the metabolic activity of the cornea epithelium, endothelium and keratocytes. The feasibility to evaluate the metabolic activity of lens epithelial cells was also demonstrated, which may be used to further investigate the pathogenesis of cataracts. The results illustrate the potential of multimodal multiphoton imaging as a novel ophthalmologic technique as well as its potential as a diagnostic tool.
Collapse
Affiliation(s)
- Ana Batista
- Biophotonics and Laser Technology, Saarland University, Saarbrücken, Germany
- JenLab GmbH, Saarbrücken, Germany
| | - Hans G Breunig
- Biophotonics and Laser Technology, Saarland University, Saarbrücken, Germany
- JenLab GmbH, Saarbrücken, Germany
| | - Aisada König
- Biophotonics and Laser Technology, Saarland University, Saarbrücken, Germany
- JenLab GmbH, Saarbrücken, Germany
| | - António M Morgado
- Department of Physics, University of Coimbra, Coimbra, Portugal
- Coimbra Institute for Biomedical Imaging and Translational Research/Institute of Nuclear Sciences Applied to Heath (CIBIT/ICNAS), University of Coimbra, Coimbra, Portugal
| | - Karsten König
- Biophotonics and Laser Technology, Saarland University, Saarbrücken, Germany
- JenLab GmbH, Saarbrücken, Germany
| |
Collapse
|
43
|
Omatiga AG, Onakpoya OH, Idowu BM, Asaleye CM, Adegbehingbe BO, Aderibigbe AS. B-mode sonographic evaluation of optic nerve sheath diameter and lens thickness in Nigerian adults with glaucoma. Afr Health Sci 2018; 18:343-351. [PMID: 30602961 PMCID: PMC6306971 DOI: 10.4314/ahs.v18i2.19] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Objective This study was done to investigate the effect(s) of glaucoma on the ocular optic nerve sheath diameter and lens thickness using B-mode ultrasonography. Materials and methods One hundred and twenty study participants were recruited; 60 subjects with glaucoma and 60 age- and sex-matched controls without glaucoma. The optic nerve sheath diameter and lens thickness of both eyes were measured using a linear high frequency transducer with frequency of 6.5–12MHz. Results The mean optic nerve sheath diameter of the glaucomatous eyes (3.57 ± 0.19mm and 3.59 ± 0.33mm on the right and left, respectively) were significantly thinner than that of controls (4.23 ± 0.34 mm and 4.26 ± 0.30 mm on the right and left, respectively; p < 0.001). There is increased mean lens thickness in the glaucomatous eyes (4.15 ± 0.43mm and 4.18 ± 0.46mm on the right and left, respectively) than in the controls (4.01 ± 0.56mm and 3.99 ± 0.45mm on the right and left, respectively) with a statistically significant difference seen in the left eye (p = 0.024). Conclusion B-mode ultrasound is a reliable tool of assessing the nerve sheath diameter and lens thickness in glaucoma. Optic nerve sheath diameter is reduced in glaucoma
Collapse
Affiliation(s)
- Achimugu G Omatiga
- Department of Radiology, Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife, Osun State, Nigeria
| | - Oluwatoyin H Onakpoya
- Department of Ophthalmology, Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife, Osun State, Nigeria
| | - Bukunmi M Idowu
- Department of Radiology, Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife, Osun State, Nigeria
| | - Christianah M Asaleye
- Department of Radiology, Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife, Osun State, Nigeria
| | - Bernice O Adegbehingbe
- Department of Ophthalmology, Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife, Osun State, Nigeria
| | - Adeniyi S Aderibigbe
- Department of Radiology, Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife, Osun State, Nigeria
| |
Collapse
|
44
|
Ploussi A, Stathopoulos I, Syrgiamiotis V, Makri T, Hatzigiorgi C, Platoni K, Carinou E, Efstathopoulos EP. DIRECT MEASUREMENTS OF SKIN, EYE LENS AND THYROID DOSE DURING PEDIATRIC BRAIN CT EXAMINATIONS. Radiat Prot Dosimetry 2018; 179:199-205. [PMID: 29140458 DOI: 10.1093/rpd/ncx251] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2017] [Accepted: 10/23/2017] [Indexed: 06/07/2023]
Abstract
Pediatric brain computed tomography (CT) is identified as the most frequent CT examination in children. The aim of the study is the direct measurement of skin, eye lens and thyroid dose in pediatric patients during brain CT examinations. The study included 35 pediatric patients who underwent brain CT examinations. The patients were categorized in three age groups: Group A (age range: 0.8-1 years), Group B (age range: 2.0-4.9 years) and Group C (age range: 5.5-15.5 years). thermoluminescent dosimeters (TLDs) were placed on the eyes, the frontal region of the head, the mastoid apophysis and the thyroid gland. The skin dose was found 16.6 ± 1.5, 38.8 ± 5.1 and 41.7 ± 9.4 mGy for Groups A, B and C, respectively. The mean dose for the eye lens was 10.5 ± 3.3, 29.9 ± 8.6 and 34.2 ± 14.9 mGy and for the thyroid 1.7 ± 0.4, 2.4 ± 0.5 and 1.9 ± 0.4 mGy for Groups A, B and C, respectively. In vivo dosimetry using TLDs proved to be an efficient method. Gantry tilting and patient's set-up seem to significantly affect eye lens dose.
Collapse
Affiliation(s)
- Agapi Ploussi
- Second Department of Radiology, University General Hospital 'Attikon', School of Medicine, National and Kapodistrian University of Athens, 12462 Athens, Greece
| | - Ioannis Stathopoulos
- Second Department of Radiology, University General Hospital 'Attikon', School of Medicine, National and Kapodistrian University of Athens, 12462 Athens, Greece
| | | | | | | | - Kalliopi Platoni
- Second Department of Radiology, University General Hospital 'Attikon', School of Medicine, National and Kapodistrian University of Athens, 12462 Athens, Greece
| | - Eleftheria Carinou
- Greek Atomic Energy Commission (GAEC), 15310 Agia Paraskevi, Attiki, Greece
| | - Efstathios P Efstathopoulos
- Second Department of Radiology, University General Hospital 'Attikon', School of Medicine, National and Kapodistrian University of Athens, 12462 Athens, Greece
| |
Collapse
|
45
|
Abstract
Purpose To investigate changes of crystalline lens position during accommodation in children with emmetropia, myopia, and hyperopia. Methods A total of 188 children (372 eyes) from 4 to 19 years old (mean age 11.3±4.43) with cycloplegic refractive error within a range +9.00 D to −9.00 D were enrolled. After a general ophthalmic examination, ultrasound biometry was performed, with the eye at a maximal accommodative effort. Cycloplegia was induced by triple installation of 1% tropicamide drops and 30 minutes later the biometric examination was repeated. Results In emmetropic eyes in the process of accommodation, the anterior pole of the crystalline lens moved forward by 0.144±0.14 mm (p ≤ 0.001); the position of the posterior pole did not change. In myopic eyes, the anterior pole moved forward by 0.071±0.13 mm (p≤0.001) and the posterior pole moved backward by 0.039±0.10 mm (p=0.003). In hyperopic eyes, the whole lens translocated anteriorly: anterior pole moved forward by 0.242±0.16 mm (p≤ 0.001) and posterior pole moved forward by 0.036±0.09 mm (p≤0.001). Differences among emmetropia, myopia, and hyperopia were statistically significant. Forward movement of the posterior pole correlated with a low axial length of the eye, and also with plus refractive error and with a smaller accommodative increase of lens thickness. Conclusions In children, accommodative changes of the crystalline lens position depend on refractive status.
Collapse
Affiliation(s)
- B J Kaluzny
- Department of Ophthalmology, Collegium Medicum, Nicolaus Copernicus University, Curie-Skłodowskiej 9, 85-094 Bydgoszcz, Poland.
| |
Collapse
|
46
|
Kurtul N, Yurttutan N, Baykara M. Investigation of the radiotherapy-related changes in the eye lens using computed tomography entropy analysis. J Xray Sci Technol 2018; 26:747-755. [PMID: 29889097 DOI: 10.3233/xst-18373] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
OBJECTIVE The aim of this study was to apply texture analysis to investigate whether there was a change in the lens following radiotherapy. PATIENTS AND METHOD Patients who received radiotherapy (RT) for head and neck cancer or brain tumor were enrolled. Computed tomography (CT) images taken in the last month before RT and the most recent images after RT were compared. Entropy values were calculated using lens attenuation values. The lens doses were obtained from the dose-volume histogram data. RESULTS A total of 55 lenses were evaluated. The mean Hounsfield Unit value of the lenses was 66.14±12.16 before RT and 72.02±9.12 after RT (p = 0.007). The mean entropy value was 1.87±0.31 before RT and this reduced to 1.31±0.34 after RT (p < 0.001), respectively. As time increased, the difference in entropy also increased (p = 0.007). A correlation close to statistical significance was determined between the entropy difference and minimum, maximum and mean lens radiation dose (p = 0.052, p = 0.052, p = 0.063, respectively). The entropy difference was significantly reduced in the >4 Gy group (p = 0.046). CONCLUSION Study results indicated that the entropy values in the lens were signifcantly changed after radiotherapy and the degree of the change associated with dose and time.
Collapse
Affiliation(s)
- Neslihan Kurtul
- Department of Radiation Oncology, Sutcu Imam University Faculty of Medicine, Kahramanmaras, Turkey
| | - Nursel Yurttutan
- Department of Radiology, Sutcu Imam University Faculty of Medicine, Kahramanmaras, Turkey
| | - Murat Baykara
- Department of Radiology, Sutcu Imam University Faculty of Medicine, Kahramanmaras, Turkey
| |
Collapse
|
47
|
Liu Y, Shen Y, Ruan H, Brodie FL, Wong TTW, Yang C, Wang LV. Time-reversed ultrasonically encoded optical focusing through highly scattering ex vivo human cataractous lenses. J Biomed Opt 2018; 23:1-4. [PMID: 29322749 PMCID: PMC5762002 DOI: 10.1117/1.jbo.23.1.010501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Accepted: 12/01/2017] [Indexed: 06/07/2023]
Abstract
Normal development of the visual system in infants relies on clear images being projected onto the retina, which can be disrupted by lens opacity caused by congenital cataract. This disruption, if uncorrected in early life, results in amblyopia (permanently decreased vision even after removal of the cataract). Doctors are able to prevent amblyopia by removing the cataract during the first several weeks of life, but this surgery risks a host of complications, which can be equally visually disabling. Here, we investigated the feasibility of focusing light noninvasively through highly scattering cataractous lenses to stimulate the retina, thereby preventing amblyopia. This approach would allow the cataractous lens removal surgery to be delayed and hence greatly reduce the risk of complications from early surgery. Employing a wavefront shaping technique named time-reversed ultrasonically encoded optical focusing in reflection mode, we focused 532-nm light through a highly scattering ex vivo adult human cataractous lens. This work demonstrates a potential clinical application of wavefront shaping techniques.
Collapse
Affiliation(s)
- Yan Liu
- California Institute of Technology, Department of Electrical Engineering, Pasadena, California, United States
| | - Yuecheng Shen
- California Institute of Technology, Andrew and Peggy Cherng Department of Medical Engineering, Pasadena, California, United States
| | - Haowen Ruan
- California Institute of Technology, Department of Electrical Engineering, Pasadena, California, United States
| | - Frank L. Brodie
- University of California, San Francisco, Department of Ophthalmology, San Francisco, California, United States
| | - Terence T. W. Wong
- California Institute of Technology, Andrew and Peggy Cherng Department of Medical Engineering, Pasadena, California, United States
| | - Changhuei Yang
- California Institute of Technology, Department of Electrical Engineering, Pasadena, California, United States
- California Institute of Technology, Andrew and Peggy Cherng Department of Medical Engineering, Pasadena, California, United States
| | - Lihong V. Wang
- California Institute of Technology, Department of Electrical Engineering, Pasadena, California, United States
- California Institute of Technology, Andrew and Peggy Cherng Department of Medical Engineering, Pasadena, California, United States
| |
Collapse
|
48
|
Schaub F, Pohl L, Enders P, Adler W, Bachmann BO, Cursiefen C, Heindl LM. Impact of corneal donor lens status on two-year course and outcome of Descemet membrane endothelial keratoplasty (DMEK). Graefes Arch Clin Exp Ophthalmol 2017; 255:2407-2414. [PMID: 29034411 DOI: 10.1007/s00417-017-3827-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2017] [Revised: 08/22/2017] [Accepted: 10/07/2017] [Indexed: 11/26/2022] Open
Abstract
PURPOSE Our purpose was to investigate the impact of lens status of corneal donors on the two-year course and clinical outcome of Descemet membrane endothelial keratoplasty (DMEK). METHODS In 181 DMEK surgeries, 136 phakic and 45 pseudophakic donor corneas were grafted. In this retrospective audit we compared the lens status of corneal donors regarding the outcome measures best spectacle-corrected visual acuity (BSCVA), central corneal thickness (CCT), and endothelial cell density (ECD) at 1, 3, 6, 12, and 24 months, as well as intra- and postoperative complication rates and graft detachment rates requiring re-bubbling. RESULTS Comparing the use of phakic and pseudophakic donor tissue in DMEK surgery, BSCVA results revealed no significant differences during the two-year course (p ≥ 0.087). CCT showed significantly lower values at 1 month (553.8 ± 56 vs. 625.2 ± 119 μm; p < 0.001) and 6 months follow-up (530.6 ± 49.9 vs. 557.3 ± 47 μm; p = 0.026) for phakic donor tissue recipients, but were comparable later (p ≥ 0.173). ECD values were statistically higher 6 (1915 ± 390 vs. 1565 ± 420 cells/mm2; p < 0.001) and 24 months postoperatively (1772 ± 384 vs. 1375 ± 377 cells/mm2; p = 0.030) in phakic donor tissue recipients. Mixed regression analyses demonstrated a significant association between ECD results and donor lens status (p = 0.029) and donor ECD (p = 0.028), but donor age did not show significant influence (p = 0.241). CONCLUSION ECD is higher in phakic corneal donors and appears to remain at a higher level during the course resulting in initially faster reduction of corneal edema compared to pseudophakic DMEK grafts. Nevertheless, pseudophakic transplants with high ECD seem to produce comparable functional results in recipients after a two year course.
Collapse
Affiliation(s)
- Friederike Schaub
- Department of Ophthalmology, University of Cologne, Kerpener Strasse 62 -, 50924, Cologne, Germany.
| | - Layla Pohl
- Department of Ophthalmology, University of Cologne, Kerpener Strasse 62 -, 50924, Cologne, Germany
| | - Philip Enders
- Department of Ophthalmology, University of Cologne, Kerpener Strasse 62 -, 50924, Cologne, Germany
| | - Werner Adler
- Department of Medical Informatics, Biometry and Epidemiology, Friedrich-Alexander, University Erlangen-Nürnberg, Erlangen, Germany
| | - Björn O Bachmann
- Department of Ophthalmology, University of Cologne, Kerpener Strasse 62 -, 50924, Cologne, Germany
| | - Claus Cursiefen
- Department of Ophthalmology, University of Cologne, Kerpener Strasse 62 -, 50924, Cologne, Germany
| | - Ludwig M Heindl
- Department of Ophthalmology, University of Cologne, Kerpener Strasse 62 -, 50924, Cologne, Germany
| |
Collapse
|
49
|
Yusufu M, Liu X, Zheng T, Fan F, Xu J, Luo Y. Hydroxypropyl methylcellulose 2% for dry eye prevention during phacoemulsification in senile and diabetic patients. Int Ophthalmol 2017; 38:1261-1273. [PMID: 28699061 DOI: 10.1007/s10792-017-0590-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2016] [Accepted: 06/05/2017] [Indexed: 12/23/2022]
Abstract
PURPOSE To assess the effect of hydroxypropyl methylcellulose (HPMC) 2% to prevent dry eye during phacoemulsification in senile and diabetic patients. METHODS This prospective interventional case series comprised 60 eyes (44 patients) with age-related cataract scheduled for standardized phacoemulsification surgery. The patients were assigned to receive either balanced saline solution (BSS, 30 eyes) or HPMC 2% (30 eyes) during surgery. Preoperative and postoperative examinations (1, 3, 7 and 30 days) included measurements of automatic noninvasive tear film breakup time (NITBUT), fluorescein staining, Schirmer I test, tear meniscus height, depth and area and subjective symptoms. Intraoperative application frequency was also assessed. RESULTS The mean age of patients was 68.7 ± 2.3 years. The application frequency of BSS during surgery was significantly reduced in HPMC group (P = 0.001). The incidence of dry eye syndrome (DES) was significantly reduced in HPMC group in both senile and diabetic patients. Scores of subjective symptoms were significantly higher in the BSS group in 1 day (P = 0.003) and 3 days (P = 0.043) postoperatively. The first and average NITBUT were significantly higher in HPMC group in 1 day and 3 days after surgery, respectively (P = 0.012 and P = 0.024, respectively). NITBUT values did not significantly change postoperatively in the HPMC group (P > 0.05), while they were significantly lower postoperatively in the BSS group. CONCLUSIONS Application of HPMC 2% during phacoemulsification reduced the incidence of DES and improved patients' satisfaction in both senile and diabetic cataract patients. It was also effective in maintaining corneal hydration and was able to significantly reduce the application frequency intraoperatively.
Collapse
Affiliation(s)
- Maierhaba Yusufu
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, People's Republic of China
- Key Laboratory of Myopia of State Health Ministry, Shanghai, People's Republic of China
- People's Hospital of Xinjiang Uygur Autonomous Region, Ürümqi, People's Republic of China
| | - Xin Liu
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, People's Republic of China
- Key Laboratory of Myopia of State Health Ministry, Shanghai, People's Republic of China
- Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China
| | - Tianyu Zheng
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, People's Republic of China
- Key Laboratory of Myopia of State Health Ministry, Shanghai, People's Republic of China
| | - Fan Fan
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, People's Republic of China
| | - Jianjiang Xu
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, People's Republic of China
- Key Laboratory of Myopia of State Health Ministry, Shanghai, People's Republic of China
- Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China
| | - Yi Luo
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, People's Republic of China.
- Key Laboratory of Myopia of State Health Ministry, Shanghai, People's Republic of China.
- Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China.
| |
Collapse
|
50
|
Tekin K, Inanc M, Kurnaz E, Bayramoglu E, Aydemir E, Koc M, Aycan Z. Objective Evaluation of Corneal and Lens Clarity in Children With Type 1 Diabetes Mellitus. Am J Ophthalmol 2017; 179:190-197. [PMID: 28528120 DOI: 10.1016/j.ajo.2017.05.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2017] [Revised: 05/07/2017] [Accepted: 05/10/2017] [Indexed: 12/15/2022]
Abstract
PURPOSE To investigate whether abnormal glucose metabolism and duration of diabetes mellitus (DM) affected the corneal and lens clarity in children with well-controlled type 1 DM and to compare the results obtained with those in healthy children. DESIGN Cross-sectional prospective study. METHODS This multicenter study enrolled 56 patients with DM and 51 control subjects. The duration of DM and the glycosylated hemoglobin (HbA1c) levels of the patients in the DM group were recorded. The Pentacam HR imaging system was used for corneal densitometry (12-mm corneal diameter) measurements. Furthermore, the lens densitometry and lens thickness (LT) measurements were performed after dilation of the pupils, using the same Pentacam HR device. RESULTS The corneal densitometry values were similar in all concentric zones and layers in both groups (P > .05, for all). The mean values of the average and maximum lens densitometry measurements of the 2 groups, as well as the mean LT values, were statistically significantly different (P = .021, P = .011, and P < .001, respectively). There were statistically significant correlations between the lens densitometry values and the duration of DM (P < .05, for all). Conversely, no statistically significant relationship was found between the lens densitometry values and HbA1c levels (r = 0.743; P = .084). CONCLUSIONS The children with type 1 DM had decreased lens clarity and increased LT, even in cases of well-controlled DM, without DR. It is reasonable to think that these changes might have been caused by the type 1 DM.
Collapse
Affiliation(s)
- Kemal Tekin
- Ophthalmology Department, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey.
| | - Merve Inanc
- Ophthalmology Department, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey
| | - Erdal Kurnaz
- Department of Pediatric Endocrinology and Metabolism, Dr Sami Ulus Children's Health and Disease Training and Research Hospital, Ankara, Turkey
| | - Elvan Bayramoglu
- Department of Pediatric Endocrinology and Metabolism, Dr Sami Ulus Children's Health and Disease Training and Research Hospital, Ankara, Turkey
| | - Emre Aydemir
- Ophthalmology Department, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey
| | - Mustafa Koc
- Ophthalmology Department, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey
| | - Zehra Aycan
- Department of Pediatric Endocrinology and Metabolism, Dr Sami Ulus Children's Health and Disease Training and Research Hospital, Ankara, Turkey
| |
Collapse
|