1
|
Rohman L, Ruggeri M, Ho A, Parel JM, Manns F. Lens Thickness Microfluctuations in Young and Prepresbyopic Adults During Steady-State Accommodation. Invest Ophthalmol Vis Sci 2023; 64:12. [PMID: 36753168 PMCID: PMC9919620 DOI: 10.1167/iovs.64.2.12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 01/22/2023] [Indexed: 02/09/2023] Open
Abstract
Purpose To determine whether lens mechanical dynamics change with age and with accommodative demands. Methods Lens thickness microfluctuations were measured using a high-speed custom-built spectral domain optical coherence tomography system in five young adults (20 to 25 years old) at 0 diopters (D), 2 D, 4 D, and maximum accommodative demand and in five prepresbyopes (38 to 45 years old) under relaxed and maximal accommodation. For each state, the measurements were repeated four times during the same session. Images of the central 2-mm zone of the lens comprising 170 A-lines/frame were acquired for 10 seconds, and axial lens thickness change was measured. Lens thickness microfluctuations (µm²/Hz) were assessed by integrating the power spectrum of lens thickness microfluctuations between 0 and 4 Hz. Results The amplitude of lens microfluctuations was higher in the accommodated states than in the relaxed state in both age groups. Lens microfluctuations were higher in young adult participants than in prepresbyopes, with a significant difference in relaxed and maximally accommodated states (P = 0.04 and P = 0.04). In the young participants, the amplitude of microfluctuations reached a plateau at maximum accommodation. Conclusions Lens mechanical dynamics are both age and accommodation dependent. The decrease in lens thickness microfluctuations with age is consistent with an age-related increase in lens stiffness or decrease of the ciliary muscle displacement. The lens does not contribute to the high-frequency component of ocular dioptric microfluctuations.
Collapse
Affiliation(s)
- Leana Rohman
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida, United States
| | - Marco Ruggeri
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida, United States
| | - Arthur Ho
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida, United States
- Brien Holden Vision Institute, Sydney, New South Wales, Australia
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Jean-Marie Parel
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida, United States
- Brien Holden Vision Institute, Sydney, New South Wales, Australia
| | - Fabrice Manns
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States
- Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida, United States
| |
Collapse
|
2
|
Abstract
Abstract
The Editors welcome topical correspondence from readers relating to articles published in the Journal. Responses should be sent electronically via the BJS website (www.bjs.co.uk). All letters will be reviewed and, if approved, appear on the website. A selection of these will be edited and published in the Journal. Letters must be no more than 250 words in length.
Collapse
|