1
|
Lee YH, Yoon HJ, Yang SS, Lee IK, Jo WS, Jeong SK, Oh SJ, Kim J, Lee Y, Seong KM. Lessons on harmonization of scoring criteria for dicentric chromosome assay in South Korea. Int J Radiat Biol 2024; 100:709-714. [PMID: 38394348 DOI: 10.1080/09553002.2024.2316603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Accepted: 01/23/2024] [Indexed: 02/25/2024]
Abstract
PURPOSE Networking with other biodosimetry laboratories is necessary to assess the radiation exposure of many individuals in large-scale radiological accidents. The Korea biodosimetry network, K-BioDos, prepared harmonized scoring guidelines for dicentric chromosome assay to obtain homogeneous results within the network and investigated the efficiency of the guidelines. MATERIALS AND METHODS Three laboratories in K-BioDos harmonized the scoring guidelines for dicentric chromosome assay. The results of scoring dicentric chromosomes using the harmonized scoring guidelines were compared with the laboratories' results using their own methods. Feedback was collected from the scorers following the three intercomparison exercises in 3 consecutive years. RESULTS K-BioDos members showed comparable capacity to score dicentrics in the three exercises. However, the results of the K-BioDos guidelines showed no significant improvement over those of the scorers' own methods. According to the scorers, our harmonized guidelines led to more rejected metaphases and ultimately decreased the number of scorable metaphases compared with their own methods. Moreover, the scoring time was sometimes longer with the K-BioDos protocol because some scorers were not yet familiar with the guidelines, though most scorers reported that the time decreased or was unchanged. These challenges may cause low adherence to the guidelines. Most scorers expressed willingness to use the guidelines to select scorable metaphases or identify dicentrics for other biodosimetry works, whereas one did not want to use it due to the difference from their calibration curves. CONCLUSIONS We identified potential resistance to following the harmonized guidelines and received requests for more detailed methods. Our findings suggest that the harmonized criteria should be continually updated, and education and training should be provided for all scorers. These changes could allow members within the biodosimetry network to successfully collaborate and support each other in large-scale radiological accidents.
Collapse
Affiliation(s)
- Yang Hee Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center (NREMC), Korea Institute of Radiological & Medical Sciences (KIRAMS), Seoul, Republic of Korea
| | - Hyo Jin Yoon
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center (NREMC), Korea Institute of Radiological & Medical Sciences (KIRAMS), Seoul, Republic of Korea
| | - Su San Yang
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center (NREMC), Korea Institute of Radiological & Medical Sciences (KIRAMS), Seoul, Republic of Korea
| | - In Kyung Lee
- Korea Hydro & Nuclear Power Co, Radiation Health Institute, Seoul, Republic of Korea
| | - Wol Soon Jo
- Research Center, Dong Nam Institute of Radiological and Medical Sciences (DIRAMS), Busan, Republic of Korea
| | - Soo Kyung Jeong
- Research Center, Dong Nam Institute of Radiological and Medical Sciences (DIRAMS), Busan, Republic of Korea
| | - Su Jung Oh
- Research Center, Dong Nam Institute of Radiological and Medical Sciences (DIRAMS), Busan, Republic of Korea
| | - Jiin Kim
- Department of Medical Sciences, Graduate School, Soonchunhyang University, Asan, Republic of Korea
| | - Younghyun Lee
- Department of Medical Sciences, Graduate School, Soonchunhyang University, Asan, Republic of Korea
- Department of Biomedical Laboratory Science, College of Medical Sciences, Soonchunhyang University, Asan, Republic of Korea
| | - Ki Moon Seong
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center (NREMC), Korea Institute of Radiological & Medical Sciences (KIRAMS), Seoul, Republic of Korea
| |
Collapse
|
2
|
Furukawa A. The implementation of artificial intelligence to the low-cost metaphase finder. RADIATION PROTECTION DOSIMETRY 2023; 199:1460-1464. [PMID: 37721057 DOI: 10.1093/rpd/ncad144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 03/06/2023] [Accepted: 04/12/2023] [Indexed: 09/19/2023]
Abstract
Biological dosimetry is used to estimate one's dose by biological phenomena. The most popular and 'gold standard' phenomenon is the appearance of dicentric chromosomes in metaphases. The metaphase finder is a tool for biological dosimetry that finds metaphase cells on glass slides. It consists of an automated microscope, auto-focus system, X-Y stage, camera and computer. It does the image analysis of the microscopic images of the glass slides and displays the positions of metaphase cells. In this paper, the author reported that the prototype of AI-implemented metaphase finder was combined with the microscope system by file sharing and image transfer program, and that the metaphase finder system's accuracy was compared with previous non-AI system, using the same samples.
Collapse
Affiliation(s)
- Akira Furukawa
- Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
| |
Collapse
|
3
|
Metaphase Cells Enrichment for Efficient Use in the Dicentric Chromosome Assay. Cell Biochem Biophys 2022; 80:647-656. [PMID: 36216973 DOI: 10.1007/s12013-022-01106-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Accepted: 09/26/2022] [Indexed: 11/03/2022]
Abstract
The dicentric chromosome assay (DCA), is considered the 'gold standard' for radiation biodosimetry. Yet, DCA, as currently implemented, may be impractical for emergency response applications, especially when time is of the essence, owing to its labor-intensive and time-consuming nature. The growth of a primary lymphocyte culture for 48 h in vitro is required for DCA, and manual scoring of dicentric chromosomes (DCs) requires an additional 24-48 h, resulting in an overall processing time of 72-96 h for dose estimation. In order to improve this timing. we introduce a protocol that will detect the metaphase cells in a population of cells, and then will harvest only those metaphase cells. Our metaphase enrichment approach is based on fixed human lymphocytes incubated with monoclonal, anti-phosphorylated H3 histone (ser 10). Antibodies against this histone have been shown to be specific for mitotic cells. Colcemid is used to arrest the mitotic cells in metaphase. Following that, a flow-cytometric sorting apparatus isolates the mitotic fraction from a large population of cells, in a few minutes. These mitotic cells are then spread onto a slide and treated with our C-Banding procedure [Gonen et al. 2022], to visualize the centromeres with DAPI. This reduces the chemical processing time to ~2 h. This reduces the time required for the DCA and makes it practical for a much wider set of applications, such as emergency response following exposure of a large population to ionizing radiation.
Collapse
|
4
|
Lee Y, Kim SH, Lee YH, Yang SS, Yoon HJ, Wilkins RC, Jang S. Application of a semi-automated dicentric scoring system in triage and monitoring occupational radiation exposure. Front Public Health 2022; 10:1002501. [PMID: 36339161 PMCID: PMC9631783 DOI: 10.3389/fpubh.2022.1002501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 10/06/2022] [Indexed: 01/27/2023] Open
Abstract
The dicentric chromosome assay (DCA) is considered the gold standard for radiation biodosimetry, but it is limited by its long dicentric scoring time and need for skilled scorers. The automation of scoring dicentrics has been considered a strategy to overcome the constraints of DCA. However, the studies on automated scoring methods are limited compared to those on conventional manual DCA. Our study aims to assess the performance of a semi-automated scoring method for DCA using ex vivo and in vivo irradiated samples. Dose estimations of 39 blind samples irradiated ex vivo and 35 industrial radiographers occupationally exposed in vivo were estimated using the manual and semi-automated scoring methods and subsequently compared. The semi-automated scoring method, which removed the false positives of automated scoring using the dicentric chromosome (DC) scoring algorithm, had an accuracy of 94.9% in the ex vivo irradiated samples. It also had more than 90% accuracy, sensitivity, and specificity to distinguish binary dose categories reflecting clinical, diagnostic, and epidemiological significance. These data were comparable to those of manual DCA. Moreover, Cohen's kappa statistic and McNemar's test showed a substantial agreement between the two methods for categorizing in vivo samples into never and ever radiation exposure. There was also a significant correlation between the two methods. Despite of comparable results with two methods, lower sensitivity of semi-automated scoring method could be limited to assess various radiation exposures. Taken together, our findings show the semi-automated scoring method can provide accurate dose estimation rapidly, and can be useful as an alternative to manual DCA for biodosimetry in large-scale accidents or cases to monitor radiation exposure of radiation workers.
Collapse
Affiliation(s)
- Younghyun Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea,Department of Biomedical Laboratory Science, College of Medical Sciences, Soonchunhyang University, Asan, South Korea
| | - Seung Hyun Kim
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Yang Hee Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Su San Yang
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Hyo Jin Yoon
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Ruth C. Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, ON, Canada
| | - Seongjae Jang
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea,*Correspondence: Seongjae Jang
| |
Collapse
|
5
|
Sholom S, McKeever SWS, Escalona MB, Ryan TL, Balajee AS. A comparative validation of biodosimetry and physical dosimetry techniques for possible triage applications in emergency dosimetry. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2022; 42:021515. [PMID: 35196651 DOI: 10.1088/1361-6498/ac5815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Accepted: 02/23/2022] [Indexed: 06/14/2023]
Abstract
Large-scale radiological accidents or nuclear terrorist incidents involving radiological or nuclear materials can potentially expose thousands, or hundreds of thousands, of people to unknown radiation doses, requiring prompt dose reconstruction for appropriate triage. Two types of dosimetry methods namely, biodosimetry and physical dosimetry are currently utilized for estimating absorbed radiation dose in humans. Both methods have been tested separately in several inter-laboratory comparison exercises, but a direct comparison of physical dosimetry with biological dosimetry has not been performed to evaluate their dose prediction accuracies. The current work describes the results of the direct comparison of absorbed doses estimated by physical (smartphone components) and biodosimetry (dicentric chromosome assay (DCA) performed in human peripheral blood lymphocytes) methods. For comparison, human peripheral blood samples (biodosimetry) and different components of smartphones, namely surface mount resistors (SMRs), inductors and protective glasses (physical dosimetry) were exposed to different doses of photons (0-4.4 Gy; values refer to dose to blood after correction) and the absorbed radiation doses were reconstructed by biodosimetry (DCA) and physical dosimetry (optically stimulated luminescence (OSL)) methods. Additionally, LiF:Mg,Ti (TLD-100) chips and Al2O3:C (Luxel) films were used as reference TL and OSL dosimeters, respectively. The best coincidence between biodosimetry and physical dosimetry was observed for samples of blood and SMRs exposed toγ-rays. Significant differences were observed in the reconstructed doses by the two dosimetry methods for samples exposed to x-ray photons with energy below 100 keV. The discrepancy is probably due to the energy dependence of mass energy-absorption coefficients of the samples extracted from the phones. Our results of comparative validation of the radiation doses reconstructed by luminescence dosimetry from smartphone components with biodosimetry using DCA from human blood suggest the potential use of smartphone components as an effective emergency triage tool for high photon energies.
Collapse
Affiliation(s)
- Sergey Sholom
- Radiation Dosimetry Laboratory, Department of Physics, Oklahoma State University, Stillwater, OK, United States of America
| | - Stephen W S McKeever
- Radiation Dosimetry Laboratory, Department of Physics, Oklahoma State University, Stillwater, OK, United States of America
| | - Maria B Escalona
- Cytogenetic Biodosimetry Laboratory, Radiation Emergency Assistance Center/Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN, United States of America
| | - Terri L Ryan
- Cytogenetic Biodosimetry Laboratory, Radiation Emergency Assistance Center/Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN, United States of America
| | - Adayabalam S Balajee
- Cytogenetic Biodosimetry Laboratory, Radiation Emergency Assistance Center/Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN, United States of America
| |
Collapse
|
6
|
Abstract
The dicentric chromosome (DC) assay accurately quantifies exposure to radiation; however, manual and semi-automated assignment of DCs has limited its use for a potential large-scale radiation incident. The Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) software automates unattended DC detection and determines radiation exposures, fulfilling IAEA criteria for triage biodosimetry. This study evaluates the throughput of high-performance ADCI (ADCI-HT) to stratify exposures of populations in 15 simulated population scale radiation exposures. ADCI-HT streamlines dose estimation using a supercomputer by optimal hierarchical scheduling of DC detection for varying numbers of samples and metaphase cell images in parallel on multiple processors. We evaluated processing times and accuracy of estimated exposures across census-defined populations. Image processing of 1744 samples on 16,384 CPUs required 1 h 11 min 23 s and radiation dose estimation based on DC frequencies required 32 sec. Processing of 40,000 samples at 10 exposures from five laboratories required 25 h and met IAEA criteria (dose estimates were within 0.5 Gy; median = 0.07). Geostatistically interpolated radiation exposure contours of simulated nuclear incidents were defined by samples exposed to clinically relevant exposure levels (1 and 2 Gy). Analysis of all exposed individuals with ADCI-HT required 0.6–7.4 days, depending on the population density of the simulation.
Collapse
|
7
|
Alsbeih GA, Al-Hadyan KS, Al-Harbi NM, Bin Judia SS, Moftah BA. Establishing a Reference Dose-Response Calibration Curve for Dicentric Chromosome Aberrations to Assess Accidental Radiation Exposure in Saudi Arabia. Front Public Health 2021; 8:599194. [PMID: 33425838 PMCID: PMC7793750 DOI: 10.3389/fpubh.2020.599194] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 10/30/2020] [Indexed: 01/17/2023] Open
Abstract
In cases of nuclear and radiological accidents, public health and emergency response need to assess the magnitude of radiation exposure regardless of whether they arise from disaster, negligence, or deliberate act. Here we report the establishment of a national reference dose–response calibration curve (DRCC) for dicentric chromosome (DC), prerequisite to assess radiation doses received in accidental exposures. Peripheral blood samples were collected from 10 volunteers (aged 20–40 years, median = 29 years) of both sexes (three females and seven males). Blood samples, cytogenetic preparation, and analysis followed the International Atomic Energy Agency EPR-Biodosimetry 2011 report. Irradiations were performed using 320 kVp X-rays. Metafer system was used for automated and assisted (elimination of false-positives and inclusion of true-positives) metaphases findings and DC scoring. DC yields were fit to a linear–quadratic model. Results of the assisted DRCC showed some variations among individuals that were not statistically significant (homogeneity test, P = 0.66). There was no effect of age or sex (P > 0.05). To obtain representative national DRCC, data of all volunteers were pooled together and analyzed. The fitted parameters of the radiation-induced DC curve were as follows: Y = 0.0020 (±0.0002) + 0.0369 (±0.0019) *D + 0.0689 (±0.0009) *D2. The high significance of the fitted coefficients (z-test, P < 0.0001), along with the close to 1.0 p-value of the Poisson-based goodness of fit (χ2 = 3.51, degrees of freedom = 7, P = 0.83), indicated excellent fitting with no trend toward lack of fit. The curve was in the middle range of DRCCs published in other populations. The automated DRCC over and under estimated DCs at low (<1 Gy) and high (>2 Gy) doses, respectively, with a significant lack of goodness of fit (P < 0.0001). In conclusion, we have established the reference DRCC for DCs induced by 320 kVp X-rays. There was no effect of age or sex in this cohort of 10 young adults. Although the calibration curve obtained by the automated (unsupervised) scoring misrepresented dicentric yields at low and high doses, it can potentially be useful for triage mode to segregate between false-positive and near 2-Gy exposures from seriously irradiated individuals who require hospitalization.
Collapse
Affiliation(s)
- Ghazi A Alsbeih
- Radiation Biology Section, Biomedical Physics Department, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.,College of Medicine, Alfaisal University, Riyadh, Saudi Arabia
| | - Khaled S Al-Hadyan
- Radiation Biology Section, Biomedical Physics Department, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia
| | - Najla M Al-Harbi
- Radiation Biology Section, Biomedical Physics Department, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia
| | - Sara S Bin Judia
- Radiation Biology Section, Biomedical Physics Department, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia
| | - Belal A Moftah
- Radiation Biology Section, Biomedical Physics Department, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.,Medical Physics Unit, Department of Oncology, McGill University, Montreal, QC, Canada
| |
Collapse
|
8
|
Han L, Gao Y, Wang P, Lyu Y. Cytogenetic biodosimetry for radiation accidents in China. RADIATION MEDICINE AND PROTECTION 2020. [DOI: 10.1016/j.radmp.2020.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
9
|
Furukawa A. THE PROJECT OF ANOTHER LOW-COST METAPHASE FINDER (SECOND REPORT-APPLICATION OF ARTIFICIAL INTELLIGENCE). RADIATION PROTECTION DOSIMETRY 2019; 186:37-41. [PMID: 30806467 DOI: 10.1093/rpd/ncz012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Revised: 01/04/2019] [Accepted: 01/18/2019] [Indexed: 06/09/2023]
Abstract
Biological dosimetry is used to estimate individual absorbed radiation dose by quantifying an appropriate biological marker. The most popular gold-standard marker is the appearance of dicentric chromosomes in metaphase. The metaphase finder is a tool for biological dosimetry that finds metaphase cells on glass slides. The author and a software company have designed a new system and are now preparing to produce the system commercially. The metaphase finder consists of an automated microscope, a camera, and a computer. To enhance the accuracy of the system, an artificial intelligence (AI) with deep learning was tested. A total of 1709 images of the metaphase finder detected as 'metaphases' were read into a nine-layer artificial neural network to detect true metaphases. A total of 456 images were used for training, and the rest of the images were used for validation. The accuracy of AI was 0.89 for metaphases and 0.90 for non-metaphases.
Collapse
Affiliation(s)
- Akira Furukawa
- National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, Japan
| |
Collapse
|
10
|
Ryan TL, Escalona MB, Smith TL, Albanese J, Iddins CJ, Balajee AS. Optimization and validation of automated dicentric chromosome analysis for radiological/nuclear triage applications. MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS 2019; 847:503087. [PMID: 31699339 DOI: 10.1016/j.mrgentox.2019.503087] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Revised: 07/26/2019] [Accepted: 09/02/2019] [Indexed: 10/25/2022]
Abstract
Dicentric Chromosome Assay (DCA) is the most preferred cytogenetic technique for absorbed radiation dose assessment in exposed humans. However, DCA is somewhat impractical for triage application owing to its labor intensive and time consuming nature. Although lymphocyte culture for 48 h in vitro is inevitable for DCA, manual scoring of dicentric chromosomes (DCs) requires an additional time of 24-48 h, making the overall turnaround time of 72-96 h for dose estimation. To accelerate the speed of DC analysis for dose estimation, an automated tool was optimized and validated for triage mode of scoring. Several image training files were created to improve the specificity of automated DC analysis algorithm. Accuracy and efficiency of the automated (unsupervised) DC scoring was compared with the semi-automated scoring that involved human verification and correction of DCs (elimination of false positives and inclusion of true positives). DC scoring was performed by both automated and semi-automated modes for different doses of X-rays and γ-rays (0 Gy-5 Gy). Biodoses estimated from the frequencies of DCs detected by both automated (unsupervised) and semi-automated (supervised) scoring modes were grossly similar to the actual delivered doses in the range of 0.5 to 3 Gy of low LET radiation. We suggest that the automated DC tool can be effectively used for large scale radiological/nuclear incidents where a rapid segregation is essential for prioritizing moderately or severely exposed humans to receive appropriate medical countermeasures.
Collapse
Affiliation(s)
- Terri L Ryan
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Maria B Escalona
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Tammy L Smith
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Joseph Albanese
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, CT, USA
| | - Carol J Iddins
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Adayabalam S Balajee
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA.
| |
Collapse
|
11
|
Ryan TL, Pantelias AG, Terzoudi GI, Pantelias GE, Balajee AS. Use of human lymphocyte G0 PCCs to detect intra- and inter-chromosomal aberrations for early radiation biodosimetry and retrospective assessment of radiation-induced effects. PLoS One 2019; 14:e0216081. [PMID: 31059552 PMCID: PMC6502328 DOI: 10.1371/journal.pone.0216081] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Accepted: 04/12/2019] [Indexed: 12/13/2022] Open
Abstract
A sensitive biodosimetry tool is required for rapid individualized dose estimation and risk assessment in the case of radiological or nuclear mass casualty scenarios to prioritize exposed humans for immediate medical countermeasures to reduce radiation related injuries or morbidity risks. Unlike the conventional Dicentric Chromosome Assay (DCA), which takes about 3–4 days for radiation dose estimation, cell fusion mediated Premature Chromosome Condensation (PCC) technique in G0 lymphocytes can be rapidly performed for radiation dose assessment within 6–8 hrs of sample receipt by alleviating the need for ex vivo lymphocyte proliferation for 48 hrs. Despite this advantage, the PCC technique has not yet been fully exploited for radiation biodosimetry. Realizing the advantage of G0 PCC technique that can be instantaneously applied to unstimulated lymphocytes, we evaluated the utility of G0 PCC technique in detecting ionizing radiation (IR) induced stable and unstable chromosomal aberrations for biodosimetry purposes. Our study demonstrates that PCC coupled with mFISH and mBAND techniques can efficiently detect both numerical and structural chromosome aberrations at the intra- and inter-chromosomal levels in unstimulated T- and B-lymphocytes. Collectively, we demonstrate that the G0 PCC technique has the potential for development as a biodosimetry tool for detecting unstable chromosome aberrations (chromosome fragments and dicentric chromosomes) for early radiation dose estimation and stable chromosome exchange events (translocations) for retrospective monitoring of individualized health risks in unstimulated lymphocytes.
Collapse
Affiliation(s)
- Terri L. Ryan
- Cytogenetic Biodosimetry Laboratory, Radiation Emergency Assistance Center/Training site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, Tennessee, United States of America
| | - Antonio G. Pantelias
- Health Physics, Radiobiology & Cytogenetics Laboratory, Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Centre for Scientific Research “Demokritos”, Ag. Paraskevi, Athens, Greece
| | - Georgia I. Terzoudi
- Health Physics, Radiobiology & Cytogenetics Laboratory, Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Centre for Scientific Research “Demokritos”, Ag. Paraskevi, Athens, Greece
| | - Gabriel E. Pantelias
- Health Physics, Radiobiology & Cytogenetics Laboratory, Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Centre for Scientific Research “Demokritos”, Ag. Paraskevi, Athens, Greece
| | - Adayabalam S. Balajee
- Cytogenetic Biodosimetry Laboratory, Radiation Emergency Assistance Center/Training site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, Tennessee, United States of America
- * E-mail:
| |
Collapse
|