Zhu L, Yu Q, Yu L, Wang L, Yang Y, Shen P, Fan Y. Optimizing the design of axial flow pump blades based on fluid characteristics. Comput Methods Biomech Biomed Engin 2024:1-10. [PMID: 38444287 DOI: 10.1080/10255842.2024.2318011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 11/15/2023] [Indexed: 03/07/2024]
Abstract
Non-physiological blood flow conditions in axial blood pumps lead to some complications, including hemolysis, platelet activation, thrombosis, and embolism. The high speed of the axial blood pump destroys large amounts of erythrocytes, thereby causing hemolysis and thrombosis. Thus, this study aims to reduce the vortices and reflux in the flow field by optimizing the axial blood pump. The axial blood pump and arterial flow field were modeled by the finite element method. The blood was assumed to be incompressible, turbulent, and Newtonian. The SST k-ω turbulence model was used. The frozen rotor method was also used to calculate the snapshot of motion. Many vortices and reflux exist in the flow field of the blood pump without optimization. The improved flow field had almost no vortex and reflux, thereby reducing the exposure time of blood. The optimized blood pump had little influence on the pressure field and shear stress field. The optimized blood pump mainly reduced the vortex, reflux, and the risk of thrombosis in the flow field. The flow field characteristics of an axial blood pump were studied, and the results showed the risk of thrombosis and hemolysis in the blood pump. In accordance with the relationship between the blade shape and the flow field, the blade of the blood pump was optimized, reducing the vortex and reflux of the flow field, as well as the risk of thrombosis.
Collapse
Affiliation(s)
- Lin Zhu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Qifeng Yu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
- Shanghai NewMed Medical Co., Ltd, Shanghai, China
| | - Lu Yu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Lizhen Wang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yuncong Yang
- Shanghai NewMed Medical Co., Ltd, Shanghai, China
| | - Peng Shen
- Shanghai NewMed Medical Co., Ltd, Shanghai, China
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| |
Collapse
|
2
|
Classification of Unsteady Flow Patterns in a Rotodynamic Blood Pump: Introduction of Non-Dimensional Regime Map. Cardiovasc Eng Technol 2015; 6:230-41. [DOI: 10.1007/s13239-015-0231-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2015] [Accepted: 06/22/2015] [Indexed: 11/25/2022]
|
3
|
Akagawa E, Lee H, Tatsumi E, Homma A, Tsukiya T, Taenaka Y. Flow visualization for different port angles of a pulsatile ventricular assist device. J Artif Organs 2011; 15:119-27. [PMID: 22038496 DOI: 10.1007/s10047-011-0614-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2008] [Accepted: 10/10/2011] [Indexed: 10/15/2022]
Abstract
The "washout effect" inside a blood pump may depend in part on the configuration of the blood pump, including its "port angle." The port angle, which is primarily decided based on anatomical considerations, may also be important from the rheological viewpoint. In our department, a next-generation diaphragm-type blood pump is being developed. In this study, we examined the influence of the port angle on flow conditions inside our new blood pump. Acrylic resin mock pumps with three different port angles (0°, 30°, and 45°) were prepared for flow visualization. Mechanical monoleaflet valves were mounted on the inlet and outlet ports of the mock pumps. Flow conditions within the mock pumps were visualized by means of particle image velocimetry during a half stroke. As a result, a high flow velocity region was seen along the main circular flow from the inlet to the outlet port. This circular flow was almost uniform and parallel to the plane of the diaphragm-housing junction (DhJ) when viewed from the inlet and outlet sides. Moreover, the proportion of high flow velocity vectors in the plane in the vicinity of the DhJ decreased as the degree of the port angle increased. In conclusion, we found that the flow behavior in the plane in the vicinity of the DhJ changed with the port angle, and that a port angle of 0° may be suitable for our diaphragm-type blood pump in view of the washout effect.
Collapse
Affiliation(s)
- Eiki Akagawa
- Department of Artificial Organs, Research Institute, National Cerebral and Cardiovascular Center, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan.
| | | | | | | | | | | |
Collapse
|
4
|
Budilarto SG, Frankowski BJ, Hattler BG, Federspiel WJ. Flow Visualization Study of a Novel Respiratory Assist Catheter. Artif Organs 2009; 33:411-8. [DOI: 10.1111/j.1525-1594.2009.00751.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
5
|
Akagawa E, Lee H, Tatsumi E, Homma A, Tsukiya T, Katagiri N, Kakuta Y, Nishinaka T, Mizuno T, Ota K, Kansaku R, Taenaka Y. Effects of mechanical valve orifice direction on the flow pattern in a ventricular assist device. J Artif Organs 2007; 10:85-91. [PMID: 17574510 DOI: 10.1007/s10047-007-0378-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2006] [Accepted: 01/23/2007] [Indexed: 11/24/2022]
Abstract
We have been developing a pneumatic ventricular assist device (PVAD) system consisting of a diaphragm-type blood pump. The objective of the present study was to evaluate the flow pattern inside the PVAD, which may greatly affect thrombus formation, with respect to the inflow valve-mount orientation. To analyze the change of flow behavior caused by the orifice direction (OD) of the valve, the flow pattern in this pump was visualized. Particle image velocimetry was used as a measurement technique to visualize the flow dynamics. A monoleaflet mechanical valve was mounted in the inlet and outlet ports of the PVAD, which was connected to a mock circulatory loop tester. The OD of the inlet valve was set at six different angles (OD = 0 degrees, 45 degrees, 90 degrees, 135 degrees, 180 degrees, and 270 degrees, where the OD opening toward the diaphragm was defined as 0 degrees ) and the pump rate was fixed at 80 bpm to create a 5.0 l/min flow rate. The main circular flow in the blood pump was affected by the OD of the inlet valve. The observed regional flow velocity was relatively low in the area between the inlet and outlet port roots, and was lowest at an OD of 90 degrees. In contrast, the regional flow velocity in this area was highest at an OD of 135 degrees. The OD is an important factor in optimizing the flow condition in our PVAD in terms of preventing flow stagnation, and the best flow behavior was realized at an OD of 135 degrees.
Collapse
Affiliation(s)
- Eiki Akagawa
- Department of Artificial Organs, the Advanced Medical Engineering Center, National Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Budilarto SG, Frankowski BJ, Hattler BG, Federspiel WJ. Flow visualization study of a pulsating respiratory assist catheter. ASAIO J 2006; 51:673-80. [PMID: 16340349 PMCID: PMC3430463 DOI: 10.1097/01.mat.0000187393.79866.9c] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Our group is currently developing an intravenous respiratory assist device that uses a centrally located pulsatile balloon within a hollow fiber bundle to enhance gas exchange rate via active mixing mechanism. We tested the hypothesis that the non-symmetric inflation and deflation of the balloon lead to both nonuniform balloon-generated secondary flow and nonuniform gas exchange rate in the fiber bundle. The respiratory catheter was placed in a 1-in. internal diameter rigid test section of an in vitro flow loop (3 L/min deionized water). Particle image velocimetry (PIV), which was used to map the velocity vector field in the lateral cross-section, showed that the balloon pulsation generated a nonuniform fluid flow surrounding the respiratory assist catheter. PIV was also used to characterize the fiber bundle movement, which was induced by the balloon pulsation. Gas permeability coefficient of the device was evaluated by using both the fluid velocity and the relative velocity between the fluid and the fiber bundle. The highest difference in the gas permeability coefficient predicted by using the relative velocity was about 17% to 23% (angular direction), which was more uniform than the 49% to 59% variation predicted by using the fluid velocity. The movement of the fiber bundle was responsible for reducing the variation in the fluid velocity passing through the bundle and for minimizing the nonuniformity of the gas permeability coefficient of the respiratory assist catheter.
Collapse
Affiliation(s)
- Stephanus G Budilarto
- Department of Chemical Engineering, McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania 15203, USA
| | | | | | | |
Collapse
|
7
|
Day SW, McDaniel JC. PIV measurements of flow in a centrifugal blood pump: time-varying flow. J Biomech Eng 2005; 127:254-63. [PMID: 15971703 DOI: 10.1115/1.1865190] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Measurements of the time-varying flow in a centrifugal blood pump operating as a left ventricular assist device (LVAD) are presented. This includes changes in both the pump flow rate as a function of the left ventricle contraction and the interaction of the rotating impeller and fixed exit volute. When operating with a pulsing ventricle, the flow rate through the LVAD varies from 0-11 L/min during each cycle of the heartbeat. Phase-averaged measurements of mean velocity and some turbulence statistics within several regions of the pump, including the inlet, blade passage, exit volute, and diffuser, are reported at 20 phases of the cardiac cycle. The transient flow fields are compared to the constant flow rate condition that was reported previously in order to investigate the transient effects within the pump. It is shown that the quasi-steady assumption is a fair treatment of the time varying flow field in all regions of this representative pump, which greatly simplifies the comprehension and modeling of this flow field. The measurements are further interpreted to identify the effects that the transient nature of the flow field will have on blood damage. Although regions of recirculation and stagnant flow exist at some phases of the cardiac cycle, there is no location where flow is stagnant during the entire heartbeat.
Collapse
Affiliation(s)
- Steven W Day
- Section of Evolution & Ecology, University of California, One Shields Avenue, Davis, CA 95616, USA.
| | | |
Collapse
|