1
|
Foong BCM, Lee WC, Khoo SKM, Kunnasegaran R. No difference in clinical outcomes when retaining or sacrificing the posterior cruciate ligament in medial congruent total knee replacement. A retrospective study. Musculoskelet Surg 2024:10.1007/s12306-024-00866-6. [PMID: 39231900 DOI: 10.1007/s12306-024-00866-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Accepted: 08/29/2024] [Indexed: 09/06/2024]
Abstract
PURPOSE The aim of this study is to evaluate the effect of retaining or sacrificing the posterior cruciate ligament (PCL) in patients who undergo primary total knee replacement (TKR) with the medial congruent (MC) implant. METHODS This retrospective study looks at patients who underwent TKR with the MC implant. Comparison was made between the group with the PCL sacrificed (MC-PCLS) and the group with the PCL retained (MC-PCLR). Range of motion (ROM), Oxford knee score (OKS), Knee society knee score (KS-KS) and Knee society function score (KS-FS) were recorded. RESULTS The study identified 76 patients. 50 in the MC-PCLS group and 26 in the MC-PCLR group. Both groups had similar patient demographics. Three months postoperatively, OKS and KS-KS had significant improvement. However, there was significant improvement in KS-FS score in the MC-PCLS group but not the MC-PCLR group (MC-PCLR: 33 ± 17, p = 0.07; MC-PCLS: 19 ± 24, p = 0.01). Twelve months postoperatively, the OKS continued to improve significantly for both groups, while the KS-FS and KS-KS scores appeared to stagnate. The ROM continued to improve significantly for the MC-PCLR group but not the MC-PCLS group (MC-PCLR: 7 ± 9, p = 0.03; MC-PCLS: 4 ± 9, p = 0.30). Both groups were similar in ROM, OKS and KSS scores at both the 3 and 12 month post-operative period. CONCLUSION There is no difference in post-operative outcomes with the PCL retained or sacrificed. As such, surgeons can consider routinely sacrificing the PCL for easier balancing of the knee and shorter surgical time.
Collapse
Affiliation(s)
- B C M Foong
- Department of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore.
| | - W C Lee
- Department of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore
| | - S K M Khoo
- Lee Kong Chian School of Medicine, Nanyang Technological University, 11 Mandalay Road, Singapore, 308232, Singapore
| | - R Kunnasegaran
- Department of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore
| |
Collapse
|
2
|
Kittisares S, Ide T, Nabae H, Suzumori K. Ergonomic dual four-bar linkage knee exoskeleton for stair ascent assistance. Front Robot AI 2023; 10:1285520. [PMID: 38124902 PMCID: PMC10731259 DOI: 10.3389/frobt.2023.1285520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Accepted: 11/14/2023] [Indexed: 12/23/2023] Open
Abstract
Introduction: Robotic exoskeletons are emerging technologies that have demonstrated their effectiveness in assisting with Activities of Daily Living. However, kinematic disparities between human and robotic joints can result in misalignment between humans and exoskeletons, leading to discomfort and potential user injuries. Methods: In this paper, we present an ergonomic knee exoskeleton based on a dual four-bar linkage mechanism powered by hydraulic artificial muscles for stair ascent assistance. The device comprises two asymmetric four-bar linkage mechanisms on the medial and lateral sides to accommodate the internal rotation of the knee and address the kinematic discrepancies between these sides. A genetic algorithm was employed to optimize the parameters of the four-bar linkage mechanism to minimize misalignment between human and exoskeleton knee joints. The proposed device was evaluated through two experiments. The first experiment measured the reduction in undesired load due to misalignment, while the second experiment evaluated the device's effectiveness in assisting stair ascent in a healthy subject. Results: The experimental results indicate that the proposed device has a significantly reduced undesired load compared to the traditional revolute joint, decreasing from 14.15 N and 18.32 N to 1.88 N and 1.07 N on the medial and lateral sides, respectively. Moreover, a substantial reduction in muscle activities during stair ascent was observed, with a 55.94% reduction in surface electromyography signal. Discussion: The reduced undesired load of the proposed dual four-bar linkage mechanism highlights the importance of the adopted asymmetrical design for reduced misalignment and increased comfort. Moreover, the proposed device was effective at reducing the effort required during stair ascent.
Collapse
|
3
|
Budhiparama NC, Lumban-Gaol I, Novito K, Hidayat H, De Meo F, Cacciola G, Cavaliere P. PCL retained is safe in medial pivot TKA-a prospective randomized trial. Knee Surg Sports Traumatol Arthrosc 2023; 31:5856-5863. [PMID: 37962615 PMCID: PMC10719124 DOI: 10.1007/s00167-023-07634-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 10/09/2023] [Indexed: 11/15/2023]
Abstract
PURPOSE Medial pivot (MP) designs resemble native knee kinematics and restore the "natural" kinematics of a knee after total knee arthroplasty (TKA). However, whether to preserve or resect the posterior cruciate ligament (PCL) is still under debate. We inquired whether sacrificing the PCL would improve range of motion, functional outcomes, and limb alignment compared to preserving the PCL in TKA using medial pivot implants (MP-TKA). METHODS This prospective, double-blinded, randomized controlled trial consisted of 33 patients (66 knees) undergoing bilateral simultaneous MP-TKA. In one knee, a PCL preservation technique was performed, and in the contralateral knee, the PCL was resected. The primary outcome was postoperative range of motion (ROM). The secondary outcomes were visual analogue scale (VAS) score for knee pain at walking, Knee Injury and Osteoarthritis Outcome Score for symptoms (KOOS-S) and quality of life (KOOS-QoL), Oxford knee score (OKS), and Forgotten Joint Score (FJS), and measurement of the mechanical femoral-tibial axis (mFTA) on X-ray images. All patients were followed up for a minimum of 2 years after surgery. RESULTS Patients who underwent MP-TKA with PCL preservation had a similar ROM at 2 years (125.45 ± 7.00 vs. 126.21 ± 6.73, p = 0.65) as those who underwent MP-TKAs with PCL resection. There was also no difference in VAS score (1.94 ± 0.79 vs. 2.00 ± 0.71, respectively, p = 0.51), OKS (39.97 ± 2.01 vs. 39.67 ± 2.03, respectively, p = 0.52), KOOS-S (84.41 ± 3.77 vs. 84.19 ± 3.57, respectively, p = 0.92), KOOS-QoL (82.94 ± 4.76 vs. 82.75 ± 4.70, respectively, p = 0.84), or FJS (72.66 ± 8.99 vs. 72.35 ± 8.64, respectively, p = 0.76) at the 2-year follow-up. No difference in the measurement of the mFTA was found between the two groups (180.27 ± 2.25 vs. 181.30 ± 2.13, respectively, p = 0.59). CONCLUSION This study demonstrated that both medial pivot TKA with PCL preservation and PCL resection achieved excellent results. There was no difference at the 2-year follow-up in terms of postoperative ROM, patient-reported outcomes, or radiographic evaluation. LEVEL OF EVIDENCE Therapeutic study, Level I.
Collapse
Affiliation(s)
- Nicolaas C Budhiparama
- Department of Orthopaedic and Traumatology, Faculty of Medicine, Universitas Airlangga, Surabaya, Indonesia.
- Department of Orthopaedics, Leiden University Medical Centre, Leiden, The Netherlands.
- Nicolaas Institute of Constructive Orthopaedic Research and Education Foundation for Arthroplasty and Sports Medicine at Medistra Hospital, Jakarta, Indonesia.
| | - Imelda Lumban-Gaol
- Nicolaas Institute of Constructive Orthopaedic Research and Education Foundation for Arthroplasty and Sports Medicine at Medistra Hospital, Jakarta, Indonesia
| | - Kiki Novito
- Nicolaas Institute of Constructive Orthopaedic Research and Education Foundation for Arthroplasty and Sports Medicine at Medistra Hospital, Jakarta, Indonesia
| | - Hendy Hidayat
- Nicolaas Institute of Constructive Orthopaedic Research and Education Foundation for Arthroplasty and Sports Medicine at Medistra Hospital, Jakarta, Indonesia
| | - Federico De Meo
- GIOMI Istituto Ortopedico del Mezzogiorno d'Italia Franco Scalabrino, Ganzirri, Via Consolare Pompea, 98165, Messina, ME, Italy
| | - Giorgio Cacciola
- GIOMI Istituto Ortopedico del Mezzogiorno d'Italia Franco Scalabrino, Ganzirri, Via Consolare Pompea, 98165, Messina, ME, Italy
| | - Pietro Cavaliere
- GIOMI Istituto Ortopedico del Mezzogiorno d'Italia Franco Scalabrino, Ganzirri, Via Consolare Pompea, 98165, Messina, ME, Italy
| |
Collapse
|
4
|
Munir S, Suzuki L, Hellman J. The Early Clinical Outcomes Following Unrestricted Caliper Verified Kinematic Alignment Using a Medial Stabilized Design Total Knee Arthroplasty With a Cruciate Retaining Insert. Arthroplast Today 2023; 24:101250. [PMID: 37920544 PMCID: PMC10618423 DOI: 10.1016/j.artd.2023.101250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 08/03/2023] [Accepted: 09/19/2023] [Indexed: 11/04/2023] Open
Abstract
Background Although various total knee arthroplasty (TKA) implant designs are widely used, the ideal TKA design is yet to be agreed upon. Although the benefits of cruciate-retaining (CR) TKA and medial stabilized (MS) TKA have been reported in literature, the early clinical outcomes of an MS TKA with CR inserts have not been reported. This study aims to report on the patient-reported clinical and radiological outcomes of MS-TKA combined with a CR insert. Methods A prospective single-surgeon series evaluated the clinical- and patient-reported outcomes of 115 patients implanted with GMK Sphere CR. Patient outcomes were assessed with the Oxford Knee Score, Knee Injury and Osteoarthritis Outcome Scores (KOOS), Forgotten Joint Score, and Visual Analogue Scale for Satisfaction. Radiological assessment for alignment along with active flexion and extension were also assessed. Results Improvement in all scores was observed between the preoperative and 1-year follow-up timepoints, with statistical significance seen for Oxford Knee Score as well as KOOS Symptoms, Pain, Sport, quality of life, and activities of daily living subscales. The mean active flexion between the preoperative and both postoperative timepoints at 6 months and 1 year was also statistically significant (P = .021 and P = .001). Conclusions MS-TKA with a CR insert can facilitate symptom relief and improve overall function of the knee after surgery. Both the patient and clinical outcomes were comparable to 1-year outcomes utilizing other MS-TKA designs and were superior to those at 1-year follow-up following implantation of CR-TKA. Most notability, the KOOS symptoms and sports score were higher for the MS-TKA with a CR insert than for an MS-TKA design.
Collapse
Affiliation(s)
- Selin Munir
- Medacta Australia, Lane Cove, New South Wales, Australia
| | - Leina Suzuki
- Medacta Australia, Lane Cove, New South Wales, Australia
| | - Jorgen Hellman
- Orthopaedic Department, John Hunter Hospital, New Lambton Heights, New South Wales, Australia
- Orthopaedic Department, Lingard Private Hospital, Merewether, New South Wales, Australia
| |
Collapse
|
5
|
Medial Pivot Versus Posterior-Stabilized Prosthesis Design in Primary Total Knee Arthroplasty: A Systematic Review and Meta-Analysis. Indian J Orthop 2022; 56:1506-1524. [PMID: 36052392 PMCID: PMC9385931 DOI: 10.1007/s43465-022-00678-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 05/30/2022] [Indexed: 02/04/2023]
Abstract
BACKGROUND Studies of clinical outcomes that compare the Medial Pivot design (MP) with the Posterior-Stabilized design (PS) were controversial. The meta-analysis was performed to summarize existing evidence, aiming to determine whether MP was superior to PS prosthesis. METHODS Search strategies followed the recommendations of the Cochrane collaboration. Electronic searches such as PubMed, Embase, Web of Science, and Cochrane were systematically searched for publications concerning medical pivot and posterior stabilized prosthesis from the inception date to April 2021. Authors also manually checked and retrieved a reference list of included publications for potential studies, which the electronic searches had not found. Two investigators independently searched, screened, and reviewed the full text of the article. Disagreements generated throughout the process were resolved by consensus, and if divergences remain, they were arbitrated by a third author. Subsequently, patients were divided into the MP and PS groups. RESULTS This study included 18 articles, comprising a total of 2614 patients with a similar baseline. The results showed the PS group had a higher risk of the patellar clunk or crepitus. However, the theoretical advantages of MP prosthesis could not translate to the difference in knee function, clinical complications, revision rate and satisfaction. Similarly, the shape and mechanism of prostheses could not affect the implant position and postoperative alignment. CONCLUSIONS The MP prosthesis can reduce the patellar clunk or crepitus rate. However, choices between the MP and PS prosthesis would not affect knee function, clinical complications, revision rate, patient satisfaction, implant position, and postoperative alignment.
Collapse
|
6
|
Lo CWT, Brodie MA, Tsang WWN, Lord SR, Yan CH, Wong AYL. Pain, balance, and mobility in people 1 year after total knee arthroplasty: a non-randomized cross-sectional pilot study contrasting posterior-stabilized and medial-pivot designs. Pilot Feasibility Stud 2022; 8:131. [PMID: 35765113 PMCID: PMC9238077 DOI: 10.1186/s40814-022-01094-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 06/15/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Total knee arthroplasty (TKA) is a common treatment for severe knee osteoarthritis. Medial-pivot TKA systems (MP-TKA) are theoretically better than posterior-stabilized TKA systems (PS-TKA) in improving static and dynamic balance of patients although it is difficult to objectively quantify these balance parameters in a clinical setting. Therefore, this pilot study aimed to evaluate the feasibility of using wearable devices in a clinical setting to examine whether people with MP-TKA have better postoperative outcomes than PS-TKA, and their balance control is more akin to age-matched asymptomatic controls. METHODS The current cross-sectional pilot study recruited 57 participants with 2 different prosthesis designs (20 PS-TKA, 18 MP-TKA) and 19 asymptomatic controls. At 1-year post-TKA, pain, knee stiffness, and physical function were assessed using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Static balance, mobility, and gait stability of the participants were evaluated based on data collected from wearable motion sensors during the near tandem stance, timed-up-and-go, and 6-min walk tests. RESULTS Compared to asymptomatic controls, both TKA groups reported significantly more pain and stiffness and demonstrated reduced functional mobility, increased stride-time-variability, and impaired balance. After Bonferroni adjustment, no significant differences in pain, balance, and mobility performance were observed between PS-TKA and MP-TKA participants 1 year after surgery. However, there was a trend for increased anteroposterior sway of the lumbar and head regions in the MP-TKA participants when undertaking the near tandem stance test. The wearable motion sensors were easy to use without any adverse effects. CONCLUSIONS It is feasible to use wearable motion sensors in a clinical setting to compare balance and mobility performance of patients with different TKA prothesis designs. Since this was a pilot study and no definite conclusions could be drawn, future clinical trials should determine the impacts of different TKA prosthesis designs on post-operative outcomes over a longer follow-up period.
Collapse
Affiliation(s)
- Cathy W T Lo
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - Matthew A Brodie
- Neuroscience Research Australia, University of New South Wales, Sydney, Australia
| | - William W N Tsang
- Department of Physiotherapy, School of Nursing and Health Studies, Hong Kong Metropolitan University, Hong Kong SAR, China
| | - Stephen R Lord
- Neuroscience Research Australia, University of New South Wales, Sydney, Australia
| | - Chun-Hoi Yan
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong SAR, China
| | - Arnold Y L Wong
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China.
| |
Collapse
|
7
|
Parratte S, Van Overschelde P, Bandi M, Ozturk BY, Batailler C. An anatomo-functional implant positioning technique with robotic assistance for primary TKA allows the restoration of the native knee alignment and a natural functional ligament pattern, with a faster recovery at 6 months compared to an adjusted mechanical technique. Knee Surg Sports Traumatol Arthrosc 2022; 31:1334-1346. [PMID: 35552475 DOI: 10.1007/s00167-022-06995-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/25/2021] [Accepted: 04/22/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE An anatomo-functional implant positioning (AFIP) technique in total knee arthroplasty (TKA) could restore physiological ligament balance (symmetric gap in extension, asymmetric gap in flexion). The purposes were to compare (1) ligament balancing in extension and flexion after TKA in the AFIP group, (2) TKA alignment, implant positioning and patellar tracking between AFIP and adjusted mechanical alignment (aMA) techniques, (3) clinical outcomes between both groups at 12 months. METHODS All robotic-assisted TKA with an AFIP technique were included (n = 40). Exclusion criteria were genu valgum (HKA angle > 183°), extra-articular deformity more than 10°, and patellar maltracking (high-grade J-sign). One control patient with a TKA implanted by an aMA technique was matched for each case, based on age, body mass index, sex, and knee alignment. Ligament balancing (medial and lateral gaps in millimeters) in full extension and at 90° of flexion after TKA in the AFIP group was assessed with the robotic system. TKA alignment (HKA angle), implants positioning (femoral and tibial coronal axis, tibial slope, joint-line orientation), patellar tracking (patellar tilt and translation) and the Knee Society Score (KSS) at 6 and 12 months were compared between both groups. The ligament balancing was compared using a t test for paired samples in the AFIP group. The radiographic measurements and KSS scores were compared between groups using a t test for independent samples. RESULTS In the AFIP group, there was no significant difference between the medial and lateral gap laxity in extension (NS). A significant opening of the lateral gap was observed in flexion compared to extension (mean: + 2.9 mm; p < 0.0001). The mean postoperative HKA angle was comparable between both groups (177.3° ± 2.1 in the AFIP group vs 176.8° ± 3.2; NS). In the AFIP group, the femoral anatomy was restored (90.9° ± 1.6) and the tibial varus was partially corrected (87.4° ± 1.8). The improvement of Knee and Function KSS at 6 months was better in the AFIP group (59.3 ± 11.9 and 51.7 ± 20, respectively, versus 49.3 ± 9.7 and 20.8 ± 13; p < 0.001). CONCLUSION The AFIP concept allowed the restoration of the native knee alignment and a natural functional ligament pattern. With a more physiological target for ligament balancing, the AFIP technique had equivalent clinical outcomes at 12 months compared to aMA, with a faster recovery. LEVEL OF EVIDENCE III retrospective therapeutic case control series.
Collapse
Affiliation(s)
- Sébastien Parratte
- Department of Orthopaedic Surgery, International Knee and Joint Centre, Abu Dhabi, United Arab Emirates
- Institute for Locomotion, Aix-Marseille University, Marseille, France
| | - Philippe Van Overschelde
- Department of Orthopaedic Surgery, AZ Maria Middelares, Buitenring Sint-Denijs 30, 9000, Ghent, Belgium
| | | | - Burak Yagmur Ozturk
- Department of Orthopaedic Surgery, International Knee and Joint Centre, Abu Dhabi, United Arab Emirates
| | - Cécile Batailler
- Department of Orthopaedic Surgery, Croix-Rousse Hospital, Lyon University Hospital, 103 Grande rue de la Croix Rousse, Lyon, France.
| |
Collapse
|
8
|
Mochizuki T, Blaha JD, Tanifuji O, Yamagiwa H, Kai S, Kawashima H. The three-dimensional quadriceps vector is most parallel to the spherical axis in Japanese varus osteoarthritic knees. Knee 2021; 33:200-209. [PMID: 34666288 DOI: 10.1016/j.knee.2021.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 06/26/2021] [Accepted: 09/05/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND The quadriceps femoris may be a reliable reference to proper alignment in total knee arthroplasty (TKA). We previously showed the quadriceps vector (QV) to be the most parallel to the spherical axis (SA-center hip to center medial condyle) for healthy knees. The purpose of this study was to determine whether the QV is the most parallel to the SA in knees with varus osteoarthritis (OA). METHODS CT imaging for 35 varus OA and 40 healthy Japanese knees was used to construct 3D models of the femur, patella and each quadriceps component for each subject. The QV was calculated using principal component analysis for direction and was compared with the relationship of the QV to the measurement axes of the lower extremity, including the anatomical, mechanical and spherical axes. RESULTS The direction of the QV for the OA knee group was different from that for the healthy knee group in 3D space (medio-lateral direction: women, p = 0.532, men, p = 0.540; antero-posterior direction: women, p = 0.141, men, p < 0.001). However, the angle of the QV in relation to measurement axes in the coronal plane was closest to the SA in both groups (around 1°), with no difference between the groups (women, p = 0.382, men, p = 0.943). CONCLUSION In the coronal plane, the SA most closely approximates the QV for both healthy and OA knees. The more posterior QV position in the 3D space may affect the patellofemoral joint.
Collapse
Affiliation(s)
- Tomoharu Mochizuki
- Division of Orthopaedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan; Department of Orthopaedic Surgery, University of Michigan, MI, USA.
| | - John David Blaha
- Department of Orthopaedic Surgery, University of Michigan, MI, USA.
| | - Osamu Tanifuji
- Division of Orthopaedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | - Hiroshi Yamagiwa
- Deparment of Orthopaedic Surgery, Saiseikai Niigata Hospital, Niigata, Japan
| | - Shin Kai
- Center for Fostering Innovative Leadership, Institute for Research Collaboration and Promotion, Niigata University, Niigata, Japan
| | - Hiroyuki Kawashima
- Division of Orthopaedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| |
Collapse
|
9
|
Tso R, Smith J, Doma K, Grant A, McEwen P. Clinical and Patient-Reported Outcomes of Medial Stabilized Versus Non-Medial Stabilized Prostheses in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis. J Arthroplasty 2021; 36:767-776.e2. [PMID: 32978025 DOI: 10.1016/j.arth.2020.07.086] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Revised: 07/19/2020] [Accepted: 07/31/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The aim of this systematic review and meta-analysis was to compare the clinical and patient-reported outcome measures (PROMs) of medial stabilized total knee arthroplasty (TKA) with non-medial stabilized TKAs. METHODS A systematic search of multiple databases was conducted in October 2019. A meta-analysis was conducted for the Knee Society Score (KSS), Knee Society Functional Score (KFS), range of motion (ROM), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Forgotten Joint Score (FJS). RESULTS A total of 857 articles yielded 21 studies eligible for inclusion with 13 studies used for quantitative analysis. The meta-analysis revealed that the medial stabilized group had a mean FJS that was 13.8 points higher than that of the non-medial stabilized TKA (mean difference [MD]: 13.83, P ≤ .0001, 95% confidence interval [CI]: 8.90-18.76, I2 = 0%) which was less than the minimal clinically important difference of 14. The medial stabilized group also demonstrated a statistically significant difference in the postoperative ROM (MD = 2.52, P = .05, 95% CI: -0.03 to 5.07, I2 = 85%) and OKS when compared with the non-medial stabilized group (MD = 1.25, P = .02, 95% CI: 0.17-2.33, I2 = 27%), but these were not clinically significant. There was no statistically or clinically significant difference in the KSS, KFS, and WOMAC scores. CONCLUSION Medial stabilized knee prostheses demonstrated no clinically significant differences for the ROM, OKS, WOMAC, KSS, and KFS. The FJS demonstrated the greatest MD and warrants further investigation. Future research is required using patient-reported outcome measures with a lower ceiling effect such as the FJS.
Collapse
Affiliation(s)
- Reece Tso
- Townsville University Hospital, Townsville, QLD, Australia; Orthopaedic Research Institute of Queensland (ORIQL), Townsville, QLD, Australia
| | - Justin Smith
- Townsville University Hospital, Townsville, QLD, Australia
| | - Kenji Doma
- James Cook University, College of Healthcare Sciences, Townsville, QLD, Australia; Orthopaedic Research Institute of Queensland (ORIQL), Townsville, QLD, Australia
| | - Andrea Grant
- Orthopaedic Research Institute of Queensland (ORIQL), Townsville, QLD, Australia
| | - Peter McEwen
- Orthopaedic Research Institute of Queensland (ORIQL), Townsville, QLD, Australia; James Cook University, College of Medicine and Dentistry, Townsville, QLD, Australia
| |
Collapse
|
10
|
Sun X, Gao X, Sun X, Su Z. Comparison of clinical and radiographic results between total knee arthroplasties using medial pivot and posterior-stabilized prosthesis: A meta-analysis. Medicine (Baltimore) 2021; 100:e23809. [PMID: 33530177 PMCID: PMC7850707 DOI: 10.1097/md.0000000000023809] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Accepted: 11/19/2020] [Indexed: 01/05/2023] Open
Abstract
OBJECTIVE To evaluate the clinical and radiographic outcomes of total knee arthroplasties (TKA) between using medial-pivot (MP) and posterior-stabilized (PS) prosthesis. Does MP prosthesis and PS prosthesis influence the clinical results of a TKA? METHODS An electronic literature search of PubMed Medline and the Cochrane Library was performed from inception to October 1, 2019. A meta-analysis to compare postoperative outcomes of Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, Knee Society Score (KSS), range of motion (ROM), complications, and radiographic results between MP and PS prosthesis were conducted. RESULTS Seven eligible studies involving 934 adult patients (MP group, n = 461; PS group, n = 473) were identified for analysis. This study showed no significant difference between the 2 groups in the WOMAC scores, KSS, ROM, and complications (P > .05). The differences of the femorotibial angle, position of implant, and patellar tilt were also not significant between the 2 groups (P > .05). CONCLUSION The present meta-analysis has shown that patients with the MP prosthesis have similar clinical results as patients with PS prosthesis. Furthermore, the radiographic results, especially patella tilt angle, were also similar between the 2 groups. Therefore, surgeons should be aware that the types of prostheses are not a decisive factor to ensure successful operation.
Collapse
Affiliation(s)
| | | | | | - Zheng Su
- Department of Medical Oncology, Weifang People's Hospital, Weifang, China
| |
Collapse
|
11
|
Miura K, Ohkoshi Y, Ino T, Ukishiro K, Kawakami K, Suzuki S, Suzuki K, Maeda T. Kinematics and center of axial rotation during walking after medial pivot type total knee arthroplasty. J Exp Orthop 2020; 7:72. [PMID: 32986185 PMCID: PMC7522154 DOI: 10.1186/s40634-020-00286-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Accepted: 09/08/2020] [Indexed: 11/10/2022] Open
Abstract
PURPOSE In recent years, the medial pivot (MP) type total knee arthroplasty (TKA) implant has been developed and marketed for achieving more natural kinematics with MP. However, little is known about the pivot pattern during walking after MP type TKA. This study aimed to determine the kinematics and center of axial rotation during walking after MP type TKA. METHODS This randomized prospective study enrolled 40 patients with MP type TKA, 20 with cruciate-substituting TKA (MP-CS group), 20 with posterior-stabilized TKA (MP-PS group), and 10 healthy volunteers (control group). The kinematics and center of axial rotation during overground walking were measured by a three-dimensional motion analysis system. The six-degrees-of-freedom kinematics of the knee were calculated by the point cluster method. RESULTS The amount of change in knee flexion in early stance phase was significantly lower in the MP-CS and MP-PS groups than in the control group. The femur showed anterior translation during early stance phase in all three groups. The median center of axial rotation in the transverse plane was predominantly on the lateral side of the knee during stance in all groups. CONCLUSIONS Kinematics during gait are thought to be determined by physical posture, the kinetic chain during weight-bearing, and the kinematic features of adjacent structures, such as the behavior of the biarticular muscles. MP-CS and MP-PS did not necessarily induce rotational motion centered on the medial ball-in-socket component during walking; translational and lateral pivoting movements were also observed. Long-term follow-up is needed to monitor for polyethylene wear and implant loosening.
Collapse
Affiliation(s)
- Kota Miura
- Department of Rehabilitation, Hakodate Orthopedics Clinic, 2-115, Ishikawa-cho, Hakodate-shi, Hokkaido, 041-0802, Japan.
| | - Yasumitsu Ohkoshi
- Department of Orthopedic Surgery, Hakodate Orthopedics Clinic, Hakodate, Japan
| | - Takumi Ino
- Department of Rehabilitation, Hakodate Orthopedics Clinic, 2-115, Ishikawa-cho, Hakodate-shi, Hokkaido, 041-0802, Japan.,Department of Physical Therapy, Faculty of Health Sciences, Hokkaido University of Science, Sapporo, Japan
| | - Kengo Ukishiro
- Department of Rehabilitation, Hakodate Orthopedics Clinic, 2-115, Ishikawa-cho, Hakodate-shi, Hokkaido, 041-0802, Japan
| | - Kensaku Kawakami
- Department of Production Systems Eng., National Institute of Technology, Hakodate College, Hakodate, Japan
| | - Sho'ji Suzuki
- Department of Complex and Intelligent Systems, Future University Hakodate, Hakodate, Japan
| | - Ko Suzuki
- Department of Orthopedic Surgery, Hakodate Orthopedics Clinic, Hakodate, Japan
| | - Tatsunori Maeda
- Department of Orthopedic Surgery, Hakodate Orthopedics Clinic, Hakodate, Japan
| |
Collapse
|
12
|
Does Patellar Resurfacing Matter? Midterm Follow-Up of MRK Total Knee Replacement. Indian J Orthop 2020; 55:56-61. [PMID: 34122755 PMCID: PMC8149519 DOI: 10.1007/s43465-020-00258-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Accepted: 09/07/2020] [Indexed: 02/04/2023]
Abstract
BACKGROUND Many designs of TKR have been developed to optimize the kinematics and improve satisfaction, including the 'medial rotating' philosophy. The purpose of this study is to report the mid-term clinical outcome of MRK knees and evaluate whether resurfacing the patella makes any difference in outcome. METHODS A retrospective analysis was done of 104 MRK total knee replacement done between 2008 and 2017. Patients were called for a review for evaluation of OKS, Baldini and Feller scores. Demographics of the patients, clinical outcome, complications were assessed. RESULTS 62 had patellar resurfacing. Mean follow-up was 74.45 months in non- resurfaced and 54.93 months in resurfaced group. Mean flexion range in both groups at final follow-up was 101.45. Median OKS at follow-up was 36 (12-47) in non-resurfaced and 37 (9-48) in resurfaced group. Patella scores were better in resurfaced group-Baldini score median (range) was 90 (25-100) in non-resurfaced v/s 100 (30-100) in resurfaced, Feller score median (range) was 25 (12-30) in non-resurfaced v/s 28 (10-30) (p 0.042) in resurfaced. The patellofemoral component of the OKS (Q5 + Q7 + Q12) median showed an improvement from 3 (1-11) to 6.5 (3-11) in non-resurfaced and from 3 (0-12) to 8 (2-12) (p 0.039) in resurfaced group. There were five complications overall (4.8%). CONCLUSION These results show a satisfactory outcome at mid-term follow-up. We found a statistically significant difference in Feller score and in the patellofemoral component of OKS between the groups of MRK knee suggesting specific benefits of patellar resurfacing with this implant.
Collapse
|
13
|
Esposito F, Freddolini M, Marcucci M, Latella L, Corvi A. Biomechanical analysis on total knee replacement patients during gait: Medial pivot or posterior stabilized design? Clin Biomech (Bristol, Avon) 2020; 78:105068. [PMID: 32535478 DOI: 10.1016/j.clinbiomech.2020.105068] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Revised: 03/03/2020] [Accepted: 05/26/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Total Knee Replacement surgery restores joint function in patients with advanced osteoarthritis. There are several prostheses available based on different mechanisms, which guarantee knee stability during Activities of Daily Living. The aim of this study is to compare ball-in-socket (or Medial Pivot) and post-cam mechanisms to detect possible differences in terms of biomechanical parameters between these two prosthesis designs and to evaluate which design is closer to physiological biomechanics. METHODS A kinematics, kinetics and electromyography lower limb analyses were performed during gait on sixty subjects: twenty with Medial Pivot prosthesis, twenty with posterior stabilized prosthesis and twenty healthy subjects to obtain a physiologic reference. FINDINGS Total Knee Replacement gait pattern for both patient groups were characterized by reduced walking speed, reduced stride length and increased stance time respect to control group. Comparison between Medial Pivot and Posterior Stabilized groups showed a reduction of knee flexion and flexor moment in patients with ball-in-socket mechanism. A prolonged muscular activity of rectus femoris was observed in Medial Pivot patients compared to Posterior Stabilized and control groups. INTERPRETATION "Stiff knee pattern" mechanism was showed for both patient groups but more enhanced in Medial Pivot patients. Even though the Posterior Stabilized design introduces the non-physiological paradoxical motion and the Medial Pivot design seems to better reproduce the physiological condylar movement as gait analysis parameters, including kinematics, kinetics and electromyographic parameters were closer to control group and, in turn, to physiological gait for the Posterior Stabilized than Medial Pivot group parameters.
Collapse
Affiliation(s)
- Francesco Esposito
- Laboratorio congiunto di Analisi del Movimento, "Fondazione ONLUS: In cammino…", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy; Industrial Engineering Department, University of Florence, Via di S. Marta 3, 50139 Firenze (FI), Italy.
| | - Marco Freddolini
- Italian Institute of Technology, Via Morego 30, 16163 Genova (GE), Italy
| | - Massimiliano Marcucci
- Laboratorio congiunto di Analisi del Movimento, "Fondazione ONLUS: In cammino…", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy; "Centro di Eccellenza Sostituzioni Articolari Toscana (C.E.S.A.T.)", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy; Health Sciences Department, University of Florence, Viale Pieraccini 6, 50139 Firenze (FI), Italy
| | - Leonardo Latella
- Laboratorio congiunto di Analisi del Movimento, "Fondazione ONLUS: In cammino…", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy; "Centro di Eccellenza Sostituzioni Articolari Toscana (C.E.S.A.T.)", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy
| | - Andrea Corvi
- Laboratorio congiunto di Analisi del Movimento, "Fondazione ONLUS: In cammino…", Piazza Spartaco Lavignini 1, 50054 Fucecchio (FI), Italy; Industrial Engineering Department, University of Florence, Via di S. Marta 3, 50139 Firenze (FI), Italy
| |
Collapse
|
14
|
French SR, Munir S, Brighton R. A Single Surgeon Series Comparing the Outcomes of a Cruciate Retaining and Medially Stabilized Total Knee Arthroplasty Using Kinematic Alignment Principles. J Arthroplasty 2020; 35:422-428. [PMID: 31611163 DOI: 10.1016/j.arth.2019.09.021] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 09/03/2019] [Accepted: 09/13/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Total knee arthroplasty (TKA) designs are developed to optimize kinematics and improve patient satisfaction. The cruciate retaining (CR) and medially stabilized (MS) TKA designs have reported good mid-term follow-up outcomes. However, reasons for consistently high rates of patient dissatisfaction following a TKA remain poorly understood. To further investigate this, we compared the short-term functional outcomes and quality of life, using patient-reported outcome measures (PROMs) and range of motion (ROM), between a CR and MS TKA. METHODS A prospective comparison was made between 2 groups (44 CR-TKAs vs 46 MS-TKAs). The Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS-12, KOOS-Short form, KOOS-Joint Replacement, Oxford Knee Score, Western Ontario and McMaster Universities Osteoarthritis Index, UCLA Activity Scale, and EuroQuality of life - 5 Dimension were completed preoperatively and 1 year postoperatively. The Forgotten Joint Score (FJS) and Visual Analogue Scale-Satisfaction were completed at 1 year postoperatively. ROM was collected preoperatively and 1 year postoperatively. RESULTS Patients who underwent an MS-TKA scored significantly better than the CR-TKA on the FJS (MS = 79.87, CR = 63.8, P = .005), the KOOS-12 Quality of Life subscale (MS = 82.8, CR = 74.4, P = .43), and the KOOS Quality of Life subscale (MS = 82.8, CR = 74.6, P = .44). There was no difference between the groups in all assessed PROMs or ROM, preoperatively and 1 year postoperatively. CONCLUSION Patients who underwent the MS-TKA scored significantly better on the FJS and the quality of life subscale of the KOOS and KOOS-12 than those who underwent a CR-TKA. All other assessed PROMs and ROM were comparable between the 2 groups and demonstrated that both implants facilitated symptom relief and improved daily function at 1 year postoperatively. These findings suggest that at short-term follow-up, the MS device is more likely to allow a patient to "forget" that a joint has been replaced and restore their quality of life. Long-term assessment of MS-TKA design outcomes in larger cohorts is recommended.
Collapse
Affiliation(s)
- Sofie R French
- Research Department, Australian Institute of Musculoskeletal Research, Wollstonecraft, New South Wales, Australia
| | - Selin Munir
- Research Department, Australian Institute of Musculoskeletal Research, Wollstonecraft, New South Wales, Australia
| | - Roger Brighton
- Orthopaedic Department, Westmead Private Hospital, Westmead, New South Wales, Australia
| |
Collapse
|
15
|
Koo YJ, Koo S. Three-Dimensional Kinematic Coupling of the Healthy Knee During Treadmill Walking. J Biomech Eng 2019; 141:2732256. [DOI: 10.1115/1.4043562] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Indexed: 11/08/2022]
Abstract
Accurate joint kinematics plays an important role in estimating joint kinetics in musculoskeletal simulations. Biplanar fluoroscopic (BPF) systems have been introduced to measure skeletal kinematics with six degrees-of-freedom. The purpose of this study was to model knee kinematic coupling using knee kinematics during walking, as measured by the BPF system. Seven healthy individuals (mean age, 23 ± 2 yr) performed treadmill walking trials at 1.2 m/s. Knee kinematics was regressed separately for the swing and stance phases using a generalized mixed effects model. Tibial anterior translation function was y=0.20x−3.09 for the swing phase and y=0.31x−0.54 for the stance phase, where x was the flexion angle and y was the tibial anterior translation. Tibial lateral and inferior translation were also regressed separately for the stance phase and the swing phase. Tibial external rotation was y=−0.002x2+0.19x−0.64 for the swing phase and y=−0.19x−1.22 for the stance phase. The tibial adduction rotation function was also calculated separately for the stance and swing phase. The study presented three-dimensional coupled motion in the knee during the stance and swing phases of walking, and demonstrated the lateral pivoting motion found in previous studies. This expanded understanding of secondary knee motion functions will benefit musculoskeletal simulation and help improve the accuracy of calculated kinetics.
Collapse
Affiliation(s)
- Young-Jun Koo
- School of Mechanical Engineering, Chung-Ang University, Seoul 06974, South Korea
| | - Seungbum Koo
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, South Korea e-mail:
| |
Collapse
|
16
|
Hollander DB, Yoshida S, Tiwari U, Saladino A, Nguyen M, Boudreaux B, Hadley B. Dynamic Analysis of Vibration, Muscle Firing, and Force as a Novel Model for Non-Invasive Assessment of Joint Disruption in the knee: A Multiple Case Report. Open Neuroimag J 2018. [DOI: 10.2174/1874440001812010120] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
We present a new method for understanding knee pathology through non-invasive techniques. The combination of electromyography (EMG), vibroarthrographic (VAG), and force analysis in proposed to examine the force transfer between unhealthy and healthy knees. A multiple case report is presented to demonstrate the technique and its potential application for future study. The comparison of four individuals’ knee characteristics will be explained using this innovative methodology.
Collapse
|
17
|
Nishitani K, Furu M, Nakamura S, Kuriyama S, Ishikawa M, Ito H, Matsuda S. No differences in patient-reported outcomes between medial pivot insert and symmetrical insert in total knee arthroplasty: A randomized analysis. Knee 2018; 25:1254-1261. [PMID: 30209014 DOI: 10.1016/j.knee.2018.08.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2018] [Revised: 05/25/2018] [Accepted: 08/15/2018] [Indexed: 02/02/2023]
Abstract
BACKGROUND Although total knee arthroplasty (TKA) using a medial pivot insert reportedly improves kinematics compared with a symmetrical insert, improvements in patient-reported outcomes have not yet been reported. The aim of this study was to determine whether insert designs influenced patient-reported outcomes. METHODS Seventy TKAs for osteoarthritis were randomly allocated to a symmetrical dish insert (SD group: 35 knees) or medial pivot insert (MP group: 35 knees). Thirty-two of the SD group (74.4 ± 6.6 years old) and 33 of the MP group (73.8 ± 6.0 years old) completed the two-year follow-up. The knee range of motion (ROM) and 2011 Knee Society score (2011KSS) were analyzed pre-operatively and postoperatively. RESULTS There was no difference in pre-operative ROM or 2011KSS (Symptom: 7.3 ± 5.9 in SD group, 8.4 ± 5.4 in MP group, P = 0.432; Satisfaction: 12.6 ± 6.9 in SD group, 11.8 ± 5.9 in MP group, P = 0.581; Activity: 35.8 ± 18.1 in SD group, 35.2 ± 18.6 in MP group, P = 0.883). At two years, although both group showed good improvement, there were no differences in ROM or 2011KSS (Symptom: 19.3 ± 5.0 in SD group, 18.3 ± 4.1 in MP group, P = 0.351; Satisfaction: 24.0 ± 7.6 in SD group, 22.9 ± 7.9 in MP group, P = 0.548; Activity: 60.3 ± 14.8 in SD group, 54.3 ± 17.3 in MP group, P = 0.137). CONCLUSIONS The medial pivot insert was not superior to the symmetrical insert in patient-reported outcomes at two years after TKA.
Collapse
Affiliation(s)
- Kohei Nishitani
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
| | - Moritoshi Furu
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Shinichiro Nakamura
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Shinichi Kuriyama
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Masahiro Ishikawa
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Hiromu Ito
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Shuichi Matsuda
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| |
Collapse
|
18
|
Samy DA, Wolfstadt JI, Vaidee I, Backstein DJ. A Retrospective Comparison of a Medial Pivot and Posterior-Stabilized Total Knee Arthroplasty With Respect to Patient-Reported and Radiographic Outcomes. J Arthroplasty 2018; 33:1379-1383. [PMID: 29276117 DOI: 10.1016/j.arth.2017.11.049] [Citation(s) in RCA: 67] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Revised: 11/13/2017] [Accepted: 11/24/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Medial pivot (MP) type total knee arthroplasty (TKA) implants are designed with a highly congruent medial tibiofemoral articulation. Compared with the cam-and-post design of the posterior-stabilized (PS) TKA, the MP-TKA design has been hypothesized to better replicate the natural kinematics of the knee. We compared the MP-TKA and PS-TKA designs, with our primary outcome measures being range of motion (ROM) and patient-reported satisfaction. METHODS This study was a retrospective comparison between the 2 groups (76 MP-TKA vs 88 PS-TKA). ROM was collected preoperatively, 6 weeks, 6 months, and 1 year postoperatively. The Forgotten Joint Score-12 (FJS-12) scores were collected at a minimum of 1 year postoperatively. RESULTS There was no statistically significant difference in age, gender, or body mass index between the groups. We found a statistical difference in preoperative ROM (MP = 120.3°, PS = 112.8°, P = .002). There was no difference in ΔROM at 6 weeks (MP = -12.36, PS = -3.79, P = .066), 6 months (MP = -4.23, PS = 2.73, P = .182), or 1 year (MP = .17, PS = 3.31, P = .499). Patients who underwent the MP-TKA scored significantly better than the PS-TKA on the FJS-12 score (MP = 59.72, PS = 44.77, P = .007). CONCLUSION We found that patients who underwent the MP-TKA scored better on the FJS than those who underwent the PS-TKA; particularly with regard to deep knee flexion and stability of the prosthesis. The MP-TKA design may offer improved patient outcomes because of its highly congruent medial tibiofemoral articulation.
Collapse
Affiliation(s)
- David A Samy
- Granovsky Gluskin Division of Orthopaedics, Sinai Health System, University of Toronto, Toronto, Ontario, Canada; University of Aberdeen, School of Medicine, Aberdeen, United Kingdom
| | - Jesse I Wolfstadt
- Granovsky Gluskin Division of Orthopaedics, Sinai Health System, University of Toronto, Toronto, Ontario, Canada
| | - Iman Vaidee
- Granovsky Gluskin Division of Orthopaedics, Sinai Health System, University of Toronto, Toronto, Ontario, Canada
| | - David J Backstein
- Granovsky Gluskin Division of Orthopaedics, Sinai Health System, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
19
|
Han HS, Kang SB. Interactive effect of femoral posterior condylar offset and tibial posterior slope on knee flexion in posterior cruciate ligament-substituting total knee arthroplasty. Knee 2018. [PMID: 29525547 DOI: 10.1016/j.knee.2018.02.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
BACKGROUND This work aimed to evaluate the changes in the femoral posterior condylar offset (PCO) and tibial slope after posterior cruciate ligament (PCL)-substituting total knee arthroplasty (TKA), and to address the presence of any interactive effect between the two on knee flexion. METHODS Fifty-two PCL-substituting TKAs were performed using a posterior referencing system. Three-dimensional reconstructed computed tomographic (CT) images were used to evaluate PCO and tibial slope before and after arthroplasty. Range of motion and clinical scores were evaluated at a mean of 3.1years postoperatively. Multivariate linear model with interaction terms was used to evaluate and compare the relationships among changes in PCO, tibial slope, and postoperative knee flexion angles. RESULTS The degree of change in PCO was greater in the lateral condyle than in the medial condyle (3.1±2.5mm and -0.5±2.8mm, respectively). Postoperative medial and lateral tibial slopes were 1.4°±1.8 and 1.4°±2.0, respectively. The mean degree of postoperative knee flexion was 125°. Analysis with interaction terms and covariate adjustment demonstrated that medial PCO and tibial slope were significantly related to knee flexion with interactive effect (P=0.011). In cases with <3° posterior tibial slope, the postoperative PCO was positively correlated to the degree of knee flexion angle. However, in cases with >3° tibial slope, PCO was negatively correlated to knee flexion. CONCLUSION Medial femoral PCO and tibial slope showed interactive effect on knee flexion after PCL-substituting TKAs. Reconstitution of the proper PCO and avoiding excessive tibial slope may be necessary.
Collapse
Affiliation(s)
- Hyuk-Soo Han
- Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, South Korea
| | - Seung-Baik Kang
- Department of Orthopedic Surgery, Seoul National University Boramae Medical Center, Seoul, South Korea.
| |
Collapse
|
20
|
Walker PS, Borukhov I. Replication and Substitution of Anatomic Stabilizing Mechanisms in a Total Knee Design. J Med Device 2017. [DOI: 10.1115/1.4037261] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
While the majority of the total knees used today are of the cruciate retaining (CR) and cruciate substituting (PS) types, the results are not ideal in terms of satisfaction, function, and biomechanical parameters. It is proposed that a design which specifically substituted for the structures which provided stability could produce normal laxity behavior, which may be a path forward to improved outcomes. Stabilizing structures of the anatomic knee were identified under conditions of low and high axial loading. The upward slope of the anterior medial tibial plateau and the anterior cruciate was particularly important under all loading conditions. A guided motion design was formulated based on this data, and then tested in a simulating machine which performed an enhanced ASTM constraint test to determine stability and laxity. The guided motion design showed much closer neutral path of motion and laxity in anterior–posterior (AP) and internal–external rotation, compared with the PS design. Particular features included absence of paradoxical anterior sliding in early flexion, and lateral rollback in higher flexion. A total knee design which replicated the stabilizing structures of the anatomical knee is likely to provide more anatomical motion and may result in improved clinical outcomes.
Collapse
Affiliation(s)
- Peter S. Walker
- Department of Orthopaedics, Hospital for Joint Diseases, New York University Langone Medical Center, 301 East 17th Street, New York, NY 10003 e-mail:
| | - Ilya Borukhov
- Department of Orthopaedics, Hospital for Joint Diseases, New York University Langone Medical Center, 301 East 17th Street, New York, NY 10003
| |
Collapse
|
21
|
A long term clinical outcome of the Medial Pivot Knee Arthroplasty System. Knee 2017; 24:447-453. [PMID: 28143683 DOI: 10.1016/j.knee.2017.01.008] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2016] [Revised: 01/15/2017] [Accepted: 01/18/2017] [Indexed: 02/02/2023]
Abstract
BACKGROUND The ideal total knee arthroplasty (TKA) should provide maximum range of motion and functional stability for all desired daily activities and, if possible, to replicate normal knee kinematics and function. The ADVANCE® Medial Pivot (AMP) Knee System was designed with a highly congruent medial compartment and a less conforming lateral compartment to more closely mimic the kinematics of the normal knee and to offer more stability through out of range of motion (ROM). The purpose of this study was to evaluate the long-term clinical and radiographic outcomes of this TKA system. METHODS Three hundred and twenty-five (325) patients (347 knees) with knee osteoarthritis underwent a TKA using the AMP prosthesis in our Department. For evaluation, objective and subjective clinical rating systems along with radiograph series were used. The average follow-up was 15.2years. RESULTS All patients showed a statistically significant improvement (p<0.0005) in the Knee Society clinical rating system, Western Ontario and McMaster Universities Osteoarthritis Index questionnaire, SF-12® questionnaire, and Oxford knee score. The majority of patients (94%) were able to perform age-appropriate activities with a mean knee flexion of 120° (range, 105°-135°) at final follow-up. Survival analysis showed a cumulative success rate of 98.8% at 17years. CONCLUSION The obtained results demonstrate excellent long-term clinical outcome for this knee design.
Collapse
|
22
|
Mochizuki T, Blaha JD, Tanifuji O, Kai S, Sato T, Yamagiwa H. The Quadriceps Vector is Most Parallel to the Spherical Axis With Minimal Difference for Gender or Ethnicity. J Arthroplasty 2016; 31:2031-7. [PMID: 27067163 DOI: 10.1016/j.arth.2016.02.044] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2015] [Revised: 02/17/2016] [Accepted: 02/19/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The extensor mechanism may be the key to kinematic alignment of total knee arthroplasty. The purpose of this study was to determine any differences in the direction of the quadriceps vector based on gender or ethnicity and to determine which anatomically derived alignment axis is closest to the quadriceps vector. METHODS Computed tomography scans and patient records for 14 Caucasians (9 men and 5 women) and 40 Japanese (19 men and 21 women) were evaluated. Three axes of alignment-anatomic, mechanical, and spherical-were identified, measured, and compared to the quadriceps vector in each case. Principal component analysis was used to determine the quadriceps vector by using 3-dimensional models of muscles on computed tomography scans. RESULTS No statistically significant differences in the orientation of the quadriceps vector were found based on gender or ethnicity, and the quadriceps vector was most closely aligned with the spherical axis. CONCLUSION Because the quadriceps is the primary knee extensor, the spherical axis therefore may be a ubiquitous guide to alignment of the arthroplasty knee based on motion.
Collapse
Affiliation(s)
- Tomoharu Mochizuki
- Department of Orthopedic Surgery, Niigata University Graduate School of Medical and Dental Science, Niigata, Japan; Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Science, Niigata, Japan; Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, Michigan
| | - J David Blaha
- Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, Michigan
| | - Osamu Tanifuji
- Department of Orthopedic Surgery, Niigata University Graduate School of Medical and Dental Science, Niigata, Japan
| | - Shin Kai
- Center for Fostering Innovative Leadership, Institute for Research Collaboration and Promotion, Niigata University, Niigata, Japan
| | - Takashi Sato
- Department of Orthopaedic Surgery, Niigata Medical Center, Niigata, Japan
| | - Hiroshi Yamagiwa
- Department of Orthopedic Surgery, Niigata University Graduate School of Medical and Dental Science, Niigata, Japan; Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Science, Niigata, Japan
| |
Collapse
|
23
|
Steinbrück A, Schröder C, Woiczinski M, Fottner A, Pinskerova V, Müller PE, Jansson V. Femorotibial kinematics and load patterns after total knee arthroplasty: An in vitro comparison of posterior-stabilized versus medial-stabilized design. Clin Biomech (Bristol, Avon) 2016; 33:42-48. [PMID: 26945720 DOI: 10.1016/j.clinbiomech.2016.02.002] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2015] [Revised: 11/02/2015] [Accepted: 02/09/2016] [Indexed: 02/07/2023]
Abstract
BACKGROUND Femorotibial kinematics and contact patterns vary greatly with different total knee arthroplasty (TKA) designs. Therefore, guided motion knee systems were developed to restore natural knee kinematics and make them more predictable. The medial stabilized TKA design is supposed to replicate physiological kinematics more than the posterior-stabilized TKA system. We conducted this study to compare a newly developed medial stabilized design with a conventional posterior-stabilized design in terms of femorotibial kinematics and contact patterns in vitro. METHODS Twelve fresh-frozen knee specimens were tested in a weight-bearing knee rig after implantation of a posterior stabilized and medial-stabilized total knee arthroplasty under a loaded squat from 20° to 120° of flexion. Femorotibial joint contact pressures in the medial and lateral compartments were measured by pressure sensitive films and knee kinematics were recorded by an ultrasonic 3-dimensional motion analysis system. FINDINGS The medial stabilized design showed a reduction of medial femorotibial translation compared to posterior-stabilized design (mean 3.5mm compared to 15.7 mm, P<0.01). In the lateral compartment, both designs showed a posterior translation of the femur with flexion, but less in the medial stabilized design (mean 14.7 mm compared to 19.0mm, P<0.01). In the medial femorotibial compartment of medial stabilized design, we observed an enlarged contact area and lower peak pressure, in contrast in the lateral compartment there was a reduced contact area and an increased peak pressure. INTERPRETATION While posterior-stabilized design enforces a medio-lateral posterior translation, the medial stabilized arthroplasty system enables a combination of a lateral translation with a medial pivot, which restores the physiological knee kinematics better.
Collapse
Affiliation(s)
- Arnd Steinbrück
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany.
| | - Christian Schröder
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany
| | - Matthias Woiczinski
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany
| | - Andreas Fottner
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany
| | - Vera Pinskerova
- 1st Orthopaedic Clinic, 1st Medical Faculty, Charles University, Prague, Czech Republic
| | - Peter E Müller
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany
| | - Volkmar Jansson
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany
| |
Collapse
|
24
|
Feng Y, Tsai TY, Li JS, Rubash HE, Li G, Freiberg A. In-vivo analysis of flexion axes of the knee: Femoral condylar motion during dynamic knee flexion. Clin Biomech (Bristol, Avon) 2016; 32:102-7. [PMID: 26777272 PMCID: PMC4779404 DOI: 10.1016/j.clinbiomech.2015.12.006] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2015] [Revised: 12/17/2015] [Accepted: 12/17/2015] [Indexed: 02/07/2023]
Abstract
BACKGROUND Transepicondylar axis and geometrical center axis are widely used for investigation of the knee kinematics and component alignment in total knee arthroplasty. However, the kinematic characteristics of these knee axes are not well defined in literature. This study investigated the femoral condylar motion during a dynamic flexion of the knee using different flexion axes. METHODS Twenty healthy knees (10 males and 10 females) were CT scanned to create 3D anatomic models. The subjects performed a single leg flexion from full extension to maximum flexion while the knees were imaged using fluoroscopes. The femoral condyle translations in anterior-posterior and proximal-distal directions were described using clinical transepicondylar axis, surgical transepicondylar axis and geometrical center axis. FINDINGS The subjects achieved -9.4° (SD 3.0°) hyperextension at full extension and 116.4° (SD 9.0°) at maximum flexion of the knee. The anterior-posterior translations of the three flexion axes were different for the medial condyle, but similar for the lateral condyle. Substantial variations of the condylar motion in proximal-distal direction were measured along the flexion path using these axes. While the surgical transepicondylar axis maintained condyle heights from full extension to 60° of flexion, geometrical center axis showed little changes in condyle heights from 30° to maximum knee flexion. The condyles moved distally beyond 90° flexion using both transepicondylar axes. INTERPRETATION The femoral condylar motion measurement is sensitive to the selection of flexion axis. The different kinematic features of these axes provide an insightful reference when selecting a flexion axis in total knee arthroplasty component alignment.
Collapse
Affiliation(s)
- Yong Feng
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, China; Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital/Harvard Medical School, 55 Fruit Street, GRJ 1215, Boston, MA 02114, United States.
| | - Tsung-Yuan Tsai
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital/Harvard Medical School, 55 Fruit Street, GRJ 1215, Boston, MA 02114, United States.
| | - Jing-Sheng Li
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital/Harvard Medical School, 55 Fruit Street, GRJ 1215, Boston, MA 02114, United States.
| | - Harry E Rubash
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital/Harvard Medical School, 55 Fruit Street, GRJ 1215, Boston, MA 02114, United States.
| | - Guoan Li
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital/Harvard Medical School, 55 Fruit Street, GRJ 1215, Boston, MA 02114, United States.
| | - Andrew Freiberg
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital/Harvard Medical School, 55 Fruit Street, GRJ 1215, Boston, MA 02114, United States.
| |
Collapse
|
25
|
Bae DK, Cho SD, Im SK, Song SJ. Comparison of Midterm Clinical and Radiographic Results Between Total Knee Arthroplasties Using Medial Pivot and Posterior-Stabilized Prosthesis-A Matched Pair Analysis. J Arthroplasty 2016; 31:419-24. [PMID: 26482685 DOI: 10.1016/j.arth.2015.09.038] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Revised: 08/31/2015] [Accepted: 09/15/2015] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Despite the theoretical advantage of a knee design that can more reliably replicate the medial pivot (MP) of the natural knee, only a few clinical studies have compared the clinical results between the MP prosthesis and another design of prosthesis. We compared the midterm results of total knee arthroplasty (TKA) using an MP prosthesis vs a posterior-stabilized prosthesis via a matched-pair analysis; we included results related to patellofemoral joint symptoms. METHODS The midterm clinical and radiographic results of 125 consecutive patients (150 knees) who underwent a TKA with the ADVANCE MP prosthesis were compared with those of a control group who had undergone a primary TKA with a posterior-stabilized prosthesis. RESULTS Values of the Knee Society's Knee Scoring System, Western Ontario and McMaster Universities Osteoarthritis Index, and Kujala and Feller scoring systems, as well as the range of motion after TKA, did not significantly differ between the 2 groups. No differences in femorotibial angle and component position, including the patella component, were observed between the 2 groups. No significant differences in the change of patella tilt angle and the postoperative patellar translation were observed between the 2 groups. CONCLUSION Patients with the MP prosthesis experienced satisfactory pain relief and a functional recovery, providing results similar to those of the posterior-stabilized prosthesis, including the resolution of patellofemoral joint symptoms.
Collapse
Affiliation(s)
- Dae Kyung Bae
- Department of Orthopaedic Surgery, School of Medicine, Kyung Hee University, Seoul, Korea
| | - Sung Do Cho
- Department of Orthopaedic Surgery, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
| | - Sang Kyu Im
- Department of Orthopaedic Surgery, School of Medicine, Kyung Hee University, Seoul, Korea
| | - Sang Jun Song
- Department of Orthopaedic Surgery, School of Medicine, Kyung Hee University, Seoul, Korea
| |
Collapse
|
26
|
Unicompartmental knee arthroplasty cannot restore the functional flexion axis of a living knee to normal. Knee Surg Sports Traumatol Arthrosc 2015; 23:3736-42. [PMID: 25209210 DOI: 10.1007/s00167-014-3296-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2014] [Accepted: 08/28/2014] [Indexed: 10/24/2022]
Abstract
PURPOSE The purpose of this study was to investigate the hypothesis that a medial unicompartmental knee arthroplasty might restore the functional flexion axis of a knee to normal. The flexion axis can be indirectly identified by tracking the vertical translation of anatomic landmarks that basically move around the flexion axis during a knee motion. If a unicompartmental knee could help restore the normal flexion axis, the anatomic landmarks after the arthroplasty would show the vertical translation similar to those of normal knees during a knee flexion. METHODS While performing a squatting motion, the kinematics of 17 knees were determined before and after a medial unicompartmental arthroplasty to calculate the vertical translation of a clinical epicondylar axis, using a three- to two-dimensional registration technique through a single-plane fluoroscopic system incorporating a biplanar static radiography. The results were compared with a normal data, and a statistical analysis including a two-way repeated-measured analysis of variance was performed. RESULTS For the medial end, from 10° to 100° knee flexion, normal, osteoarthritic, and unicompartmental knees had the average superior vertical translation of 7.3 ± 4.2, 4.3 ± 7.2, and 2.4 ± 3.1 mm, respectively, with statistical significance between normal and unicompartmental knees (p < 0.001). The vertical translation did not return to normal post-implantation. CONCLUSIONS A unicompartmental knee could not reproduce the normal flexion axis. As for clinical relevance, the changes of the implant design and surgical procedure may be necessary to obtain the normal flexion axis reproducing a normal motion. LEVEL OF EVIDENCE IV.
Collapse
|
27
|
Walker PS, Arno S, Borukhoy I, Bell CP. Characterising knee motion and laxity in a testing machine for application to total knee evaluation. J Biomech 2015; 48:3551-8. [DOI: 10.1016/j.jbiomech.2015.06.013] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Revised: 06/15/2015] [Accepted: 06/17/2015] [Indexed: 11/28/2022]
|
28
|
Jonas SC, Argyropoulos M, Al-Hadithy N, Korycki M, Lotz B, Deo SD, Satish V. Knee arthroplasty with a medial rotating total knee replacement. Midterm clinical findings: a district general experience of 38 cases. Knee 2015; 22:122-5. [PMID: 25533210 DOI: 10.1016/j.knee.2014.11.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Revised: 11/11/2014] [Accepted: 11/17/2014] [Indexed: 02/02/2023]
Abstract
BACKGROUND The Medial Rotating Knee replacement (MRK) was first used in 1994, reporting high rates of satisfaction. It is designed to replicate natural knee kinematics and improve stability and function. There are limited studies on the mid-term clinical outcomes, in particular in a district general hospital (DGH) environment. This is the first study that we are aware of that evaluates the learning curve of the implementation of this knee system in this environment. PATIENTS/METHOD Between 2007 and 2009 we performed 38 consecutive MRK replacements (MAT ORTHO, UK) in 36 patients. The mean follow-up was four years. Patients were evaluated clinically, using OKS and patient questionnaire and radiographically (good/acceptable/poor) to assess outcome. RESULTS Mean age was 73.0 years. Mean pre-operative OKS was 17.7 (range 8-29), which rose to 38.1 (range 23-48) at latest follow up (p<0.005). Overall 71% of the patients were either satisfied (29%) or very satisfied (42%). 81% felt an improvement of the ability to go up or down stairs and 92% felt stable. All poor radiographic and the majority of acceptable outcomes were experienced in the first 50% of cases. CONCLUSION The MRK can be successfully implanted in a DGH environment. It improves pain and function comparably to standard TKRs, however, subjective improvement may be higher. Radiographic evaluation shows an acceptable learning curve. LEVEL OF EVIDENCE Level IV case series.
Collapse
Affiliation(s)
- Sam C Jonas
- Great Western Hospital, Marlborough Road, Swindon SN3 6BB, United Kingdom.
| | | | - Nawfal Al-Hadithy
- Great Western Hospital, Marlborough Road, Swindon SN3 6BB, United Kingdom
| | - Marius Korycki
- Great Western Hospital, Marlborough Road, Swindon SN3 6BB, United Kingdom
| | - Benedict Lotz
- Great Western Hospital, Marlborough Road, Swindon SN3 6BB, United Kingdom
| | - Sunny D Deo
- Great Western Hospital, Marlborough Road, Swindon SN3 6BB, United Kingdom
| | - Venkat Satish
- Great Western Hospital, Marlborough Road, Swindon SN3 6BB, United Kingdom
| |
Collapse
|
29
|
Youm YS, Cho SD, Lee SH, Cho HY. Total Knee Arthroplasty Using a Posterior Cruciate Ligament Sacrificing Medial Pivot Knee: Minimum 5-year Follow-up Results. Knee Surg Relat Res 2014; 26:135-40. [PMID: 25229042 PMCID: PMC4163570 DOI: 10.5792/ksrr.2014.26.3.135] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2014] [Revised: 05/29/2014] [Accepted: 06/16/2014] [Indexed: 10/28/2022] Open
Abstract
PURPOSE To evaluate minimum 5-year follow-up clinical and radiological results of total knee arthroplasty (TKA) using a posterior cruciate ligament sacrificing (PS), non-substituting Advance Medial Pivot Knee. MATERIALS AND METHODS One hundred and twenty knees in 80 patients who could be followed up for more than 5 years after TKA using the PS Advance Medial Pivot Knee were evaluated retrospectively. The evaluations included the preoperative and postoperative range of motion (ROM), tibiofemoral angle, Knee Society (KS) knee and function scores, and Western Ontario and McMaster Universities Arthritis Index (WOMAC) score. The Kaplan-Meier method was used for survival analysis. RESULTS The ROM increased from a preoperative mean flexion contracture of 7.6° and further flexion of 115.1° to a postoperative mean flexion contracture of 1.5° and further flexion of 120.5°. The tibiofemoral angle was changed from 4.6° varus preoperatively to 5.8° valgus postoperatively. The KS knee and function scores as well as WOMAC score significantly improved after surgery (p<0.05). Complications developed in 4 cases (3.3%): 2 cases of periprosthetic patellar fracture (1.7%) and 2 cases of aseptic loosening (1.7%). The seven-year survival rate was 98.1% in the Kaplan-Meier survival analysis. CONCLUSIONS The minimum 5-year follow-up results of TKA using the PS Medial Pivot Knee were satisfactory.
Collapse
Affiliation(s)
- Yoon-Seok Youm
- Department of Orthopedic Surgery, Arthro-center, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
| | - Sung-Do Cho
- Department of Orthopedic Surgery, Arthro-center, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
| | - Seon-Ho Lee
- Department of Orthopedic Surgery, Arthro-center, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
| | - Hye-Yong Cho
- Department of Orthopedic Surgery, Arthro-center, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
| |
Collapse
|
30
|
The clinical epicondylar axis is not the functional flexion axis of the human knee. J Orthop Sci 2014; 19:451-6. [PMID: 24510360 DOI: 10.1007/s00776-014-0536-0] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2013] [Accepted: 01/16/2014] [Indexed: 10/25/2022]
Abstract
BACKGROUND The functional flexion axis (FFA) is the principal axis around which the knee moves and thus, by definition, does not move in vertical displacement relative to the tibia. The transepicondylar axis (TEA) has been reported to coincide with the FFA. If that is not true, the TEA should show vertical displacement during motion, and this hypothesis was investigated. METHODS Three-dimensional knee kinematics of 20 healthy volunteers were determined during a squatting motion via a 3-dimensional to 2-dimensional image registration technique by calculating the vertical displacement of the clinical epicondylar axis (CEA) through the full range of motion. RESULTS From 0° to 90° knee flexion, the average vertical displacement of the lateral end of the CEA was <3 mm, whereas that of the medial end was large (7.6 mm). DISCUSSION The large vertical displacement of the medial end of the CEA suggests that the CEA is not the FFA. This finding implies that the CEA may not be an appropriate axis for a TKA prosthesis having a "single radius" design. EVIDENCE LEVEL Level IV.
Collapse
|
31
|
Chinzei N, Ishida K, Tsumura N, Matsumoto T, Kitagawa A, Iguchi T, Nishida K, Akisue T, Kuroda R, Kurosaka M. Satisfactory results at 8 years mean follow-up after ADVANCE® medial-pivot total knee arthroplasty. Knee 2014; 21:387-90. [PMID: 24440451 DOI: 10.1016/j.knee.2013.10.005] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2013] [Revised: 09/26/2013] [Accepted: 10/14/2013] [Indexed: 02/02/2023]
Abstract
BACKGROUND Although good overall results have been reported with TKA, certain problems and limitations remain, primarily due to postoperative differences in joint kinematics, when compared with the normal knee. ADVANCE® Medial-Pivot TKA involves replicating the medial pivoting behavior observed in normal knees. Here, we aimed to investigate the clinical and radiological results and complications of TKA using this implant, at mid-term follow-up. METHODS From January 2001 to March 2012, we retrospectively selected 76 patients (85 knees; mean age at operation, 70.2±8.1 years; range, 51-88 years) with a mean follow-up period of 93.1±14.3 months (range, 72-132 months). Indications for TKA included primary degenerative osteoarthritis (60 knees), rheumatoid arthritis (22 knees), osteonecrosis (two knees), and osteoarthritis following high tibial osteotomy (one knee). The clinical and radiographic results were evaluated. RESULTS Kaplan-Meier survivorship analysis indicated a success rate of 98.3% (95% confidence interval, 96.6-99.9%). Comparison of pre- and postoperative knee extension angles and ranges of motion showed significant improvement postoperatively, in both the Knee Society Scores (KSS) and Knee Society Functional Scores (KSFS) (p<0.05). In one case, radiographic assessment indicated implant loosening due to infection; however, despite this complication, significant improvement of postoperative varus or valgus deformity angles were noted in all cases (p<0.05). CONCLUSION Patients undergoing ADVANCE® Medial-Pivot TKA achieved excellent clinical and radiographic results without any implant-related failures at mid-term follow-up. LEVEL OF EVIDENCE Level IV.
Collapse
Affiliation(s)
- Nobuaki Chinzei
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Japan
| | - Kazunari Ishida
- Department of Orthopaedic Surgery, Hyogo Rehabilitation Centre Central Hospital, 1070 Akebono-cho, Nishi-ku, Kobe 651-2181, Japan.
| | - Nobuhiro Tsumura
- Department of Orthopaedic Surgery, Hyogo Rehabilitation Centre Central Hospital, 1070 Akebono-cho, Nishi-ku, Kobe 651-2181, Japan
| | - Tomoyuki Matsumoto
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Japan
| | - Atsushi Kitagawa
- Department of Orthopaedic Surgery, Hyogo Rehabilitation Centre Central Hospital, 1070 Akebono-cho, Nishi-ku, Kobe 651-2181, Japan
| | - Tetsuhiro Iguchi
- Department of Orthopaedic Surgery, Hyogo Rehabilitation Centre Central Hospital, 1070 Akebono-cho, Nishi-ku, Kobe 651-2181, Japan
| | - Kotaro Nishida
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Japan
| | - Toshihiro Akisue
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Japan
| | - Ryosuke Kuroda
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Japan
| | - Masahiro Kurosaka
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Japan
| |
Collapse
|
32
|
Kim TH, Lee JS, Oh KJ. Discrepancies of Patellofemoral Indices between Supine and Standing Merchant Views. Knee Surg Relat Res 2014; 26:20-6. [PMID: 24639943 PMCID: PMC3953521 DOI: 10.5792/ksrr.2014.26.1.20] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2013] [Revised: 12/21/2013] [Accepted: 12/23/2013] [Indexed: 11/21/2022] Open
Abstract
Purpose This research was conducted to compare supine and standing Merchant views, to observe radiographic changes of the patellofemoral joint according to weight-bearing conditions, and to evaluate correlation factors affecting patellofemoral joint indices. Materials and Methods Forty-four patients without skeletal problems were selected for this study. Patellar tilt angle, lateral patellofemoral angle, congruence angle, lateral subluxation distance and lateral patellar displacement were measured on each radiograph and evaluated for statistical significance. Possible correlation factors that can affect the radiographic discrepancy were analyzed using the univariate and multivariate regression analysis. Results In the standing Merchant view, the patellar tilt angle, congruence angle and lateral patellar displacement were significantly decreased (p<0.001), whereas the lateral patellofemoral angle was significantly increased (p<0.001) compared to that in the supine Merchant view. Thigh width (p<0.001, r2=0.22) and radiographic Q-angle (p<0.001, r2=0.34) were found correlated with the radiographic discrepancy of congruence angle. Discrepancy of the lateral patella displacement increased as radiographic Q-angle increased (p=0.027, r2=0.112). Conclusions Compared with the supine Merchant view, standing (weight-bearing) Merchant view showed decreased patella tilt angle, congruence angle, and lateral patella displacement. The results indicate that both supine and standing Merchant views should be considered in the radiographic evaluation of the patellofemoral joint.
Collapse
Affiliation(s)
- Tae-Hoon Kim
- Department of Orthopedic Surgery, Konkuk University School of Medicine, Seoul, Korea
| | - Jong-Soo Lee
- Department of Orthopedic Surgery, Konkuk University School of Medicine, Seoul, Korea
| | - Kwang-Jun Oh
- Department of Orthopedic Surgery, Konkuk University School of Medicine, Seoul, Korea
| |
Collapse
|
33
|
Kim TH, Sobti A, Lee SH, Lee JS, Oh KJ. The effects of weight-bearing conditions on patellofemoral indices in individuals without and with patellofemoral pain syndrome. Skeletal Radiol 2014; 43:157-64. [PMID: 24221139 DOI: 10.1007/s00256-013-1756-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2013] [Revised: 09/03/2013] [Accepted: 10/10/2013] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The purpose of this study is to evaluate differences between the patellofemoral joint indices after supine, non-weight-bearing and standing position, and weight-bearing Merchant view radiographs in individuals without and with patellofemoral pain syndrome (PFPS). MATERIALS AND METHODS Radiographs of 44 knees without PFPS and 51 knees with PFPS were retrospectively evaluated. In both positions, the non-weight-bearing and weight-bearing Merchant views, patellar indices such as patellar tilt angle, lateral patellofemoral angle, lateral subluxation distance, lateral patellar displacement, and congruence angle were measured, respectively. The differences between the patellofemoral joint indices in knees with and without PFPS were analyzed using univariate and multivariate regression analysis, in regards to correlation factors. RESULTS The patellar tilt angle (p = 0.0002), lateral subluxation distance (p = 0.038), lateral patellar displacement (p = 0.0004), and congruence angle (p < 0.0001) on the weight-bearing Merchant view was significantly decreased in normal knees without PFPS. In pathologic knees with PFPS, the patellar tilt angle (p < 0.0001), lateral subluxation distance (p < 0.0001), lateral patella displacement (p < 0.0001), and congruence angle (p < 0.0001) on weight-bearing Merchant view was also significantly decreased. The difference between the patellofemoral indices was significantly more in knees specifically with PFPS (p < 0.05). CONCLUSIONS These results suggest that patellofemoral indices measured during non-weight-bearing supine position do not sufficiently represent the patellofemoral kinematics during normal weight-bearing activities. We conclude that this study establishes the clinical significance and relevance of assessing the patellofemoral kinematics by weight-bearing, standing Merchant view radiographs, when evaluating patients with patellofemoral problems.
Collapse
Affiliation(s)
- Tae-Hoon Kim
- Department of Orthopedic Surgery, Konkuk University School of Medicine, 4-12, Hwayang-dong, Gwangjin-gu, Seoul, 143-729, Korea,
| | | | | | | | | |
Collapse
|
34
|
Vecchini E, Christodoulidis A, Magnan B, Ricci M, Regis D, Bartolozzi P. Clinical and radiologic outcomes of total knee arthroplasty using the Advance Medial Pivot prosthesis. A mean 7 years follow-up. Knee 2012; 19:851-5. [PMID: 22571852 DOI: 10.1016/j.knee.2012.04.002] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2011] [Revised: 04/04/2012] [Accepted: 04/05/2012] [Indexed: 02/02/2023]
Abstract
BACKGROUND Medial Pivot total knee prosthesis has been designed according to studies on normal knee kinematics aiming to replicate physiological knee movement. The purpose of this study was to evaluate clinical and radiologic results of the Advance Medial Pivot Total Knee Arthroplasty, at a mean follow-up of seven years. METHODS One hundred seventy two Medial Pivot total knee arthroplasties in 160 consecutive patients have been evaluated using the American Knee Society Score and the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. Statistical analysis was performed using the Student's t-test and the Wilcoxon matched-pairs signed-rank (Mann-Whitney) test in order to evaluate the significance of differences within the groups of patients. Patients compliance was 93.75% thus only six patients (3.75%) lost to follow-up and four patients (2.5%) died for reasons unrelated to the surgery. RESULTS The mean Knee Society score and range of motion was improved from 77.6 points and 97.7° to 152.8 points and 112.5° respectively (p<.001). In total 85.8% and 82.4% of the knees had an excellent (≥ 80) or good (70-79) functional and knee scores respectively. Relief of pain was satisfactory in 88.9% of the patients, while 96% of the patients return to age-related daily life activities. Stability and comfort during walking was subjectively judged by the patients as satisfactory in about 90%. Anterior knee pain was observed in eight patients (5.4%). The Kaplan-Meier survivorship analysis showed a cumulative success rate of 98.6%. CONCLUSIONS The results are encouraging but longer follow-up of this cohort is necessary in the study of this specific design. Level of evidence IV.
Collapse
Affiliation(s)
- E Vecchini
- Department of Orthopaedics and Traumatology, University of Verona, GB Rossi Hospital, Verona, Italy
| | | | | | | | | | | |
Collapse
|
35
|
Assessment of a medial pivot total knee arthroplasty design in a cadaveric knee extension test model. J Arthroplasty 2012; 27:1460-1468.e1. [PMID: 22906409 DOI: 10.1016/j.arth.2012.02.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2010] [Accepted: 02/07/2012] [Indexed: 02/01/2023] Open
Abstract
A total knee has been designed to mimic less-compliant medial and more-compliant lateral behavior. In vivo testing compared open-kinematic chain behaviors of cadaver knees in their normal state and after implantation of the knee prosthesis. Specimen's limbs were computed tomography scanned, and infrared arrays on tibia and femur were registered to bone markers. Motion of the joint and quadriceps force were reported from 90° flexion to full extension. Less medial and more lateral anterior-posterior motion was seen in both the intact and the implanted knees. Tibiofemoral rotation and translation were similar in direction but were reduced in magnitude for the prosthetic knees. Quadriceps force, defined as that applied force required to extend the knee, required after implantation was variable between specimens but not statistically different from the intact condition. The prosthesis tested exhibits kinematic behavior similar to that in their normal state, with no difference in quadriceps force required for extension.
Collapse
|
36
|
Stan G, Orban H, Gruionu L, Gheorghe P. Coronal malposition effects in total knee arthroplasty: a finite element analysis. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2012; 23:685-90. [DOI: 10.1007/s00590-012-1051-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2012] [Accepted: 07/02/2012] [Indexed: 11/29/2022]
|
37
|
Hoshino Y, Tashman S. Internal tibial rotation during in vivo, dynamic activity induces greater sliding of tibio-femoral joint contact on the medial compartment. Knee Surg Sports Traumatol Arthrosc 2012; 20:1268-75. [PMID: 22041716 DOI: 10.1007/s00167-011-1731-6] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2011] [Accepted: 10/13/2011] [Indexed: 11/24/2022]
Abstract
PURPOSE Although extensive research has been conducted on rotational kinematics, the internal/external rotation of the tibio-femoral joint is perhaps less important for protecting joint health than its effect on joint contact mechanics. The purpose of this study was to evaluate tibio-femoral joint contact paths during a functional activity (running) and investigate the relationship between these arthrokinematic measures and traditional kinematics (internal/external rotation). METHODS Tibio-femoral motion was assessed for the contralateral (uninjured) knees of 29 ACL-reconstructed individuals during downhill running, using dynamic stereo X-ray combined with three-dimensional CT bone models to produce knee kinematics and dynamic joint contact paths. The joint contact sliding length was estimated by comparing femoral and tibial contact paths. The difference in sliding length between compartments was compared to knee rotation. RESULTS Sliding length was significantly larger on the medial side (10.2 ± 3.8 mm) than the lateral side (2.3 ± 4.0 mm). The difference in sliding length between compartments (mean 7.8 ± 3.0 mm) was significantly correlated with internal tibial rotation (P < 0.01, R (2) = 0.74). CONCLUSION The relationship between rotational knee kinematics and joint contact paths was specifically revealed as greater tibial internal rotation was associated with larger magnitude of sliding motion in the medial compartment. This could suggest that lateral pivot movement occurs during running. CLINICAL RELEVANCE Rotational kinematics abnormality should be treated for restoring normal balance of joint sliding between medial and lateral compartments and preventing future osteoarthritis. LEVEL OF EVIDENCE Prognostic studies, Level II.
Collapse
Affiliation(s)
- Yuichi Hoshino
- Department of Orthopaedic Surgery, Orthopaedic Research Laboratories, University of Pittsburgh, 3820 South Water St., Pittsburgh, PA 15203, USA
| | | |
Collapse
|
38
|
Knee functional flexion axis in osteoarthritic patients: comparison in vivo with transepicondylar axis using a navigation system. Knee Surg Sports Traumatol Arthrosc 2012; 20:552-8. [PMID: 21755359 DOI: 10.1007/s00167-011-1604-z] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2010] [Accepted: 07/01/2011] [Indexed: 10/18/2022]
Abstract
PURPOSE No study, up to now, has examined the effect of arthritis on pathologic subjects using functional flexion axis (FFA). The purpose of this study is to understand whether arthritis affects somehow the FFA evaluation and to assess whether the FFA could be considered a usable reference for implant positioning for osteoarthritic knees. METHODS Using a navigation system, FFA orientation was evaluated intraoperatively (computed with the mean helical axis method) in three different ranges of motion (0°-120°; 35°-80°; 35°-120°) and in two different planes (coronal and axial), for 111 osteoarthritis patients undergoing total knee arthroplasty. The results were compared with a control group of 60 patients that underwent ACL reconstruction. The angle between the transepicondylar axis (TEA) and FFA was computed. RESULTS Results showed in arthritic knees on frontal plane, an average difference between TEA and FFA of -2.8° ± 5.0° while on axial plane it was 0.6° ± 4.7°. No statistical difference was found between the three ranges in axial view, whereas some difference was found in frontal view (P < 0.0001). The TEA-FFA angle was not correlated with limb alignment on axial plane, while it was, even if poor, in frontal plane. In the control group, in frontal and in axial view, no statistical difference was found for the angle between TEA and FFA. CONCLUSIONS FFA can be used as reference for implant positioning in axial plane also in pathologic knees, while for the frontal plane further investigations are required.
Collapse
|
39
|
Tanifuji O, Sato T, Kobayashi K, Mochizuki T, Koga Y, Yamagiwa H, Omori G, Endo N. Three-dimensional in vivo motion analysis of normal knees using single-plane fluoroscopy. J Orthop Sci 2011; 16:710-8. [PMID: 21892788 DOI: 10.1007/s00776-011-0149-9] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2011] [Accepted: 08/10/2011] [Indexed: 11/25/2022]
Abstract
BACKGROUND Analysis of the movement of anatomically defined reference axes at the femoral condyles relative to the tibia is appropriate for evaluating knee kinematics. However, such parameters have been previously employed only in studies utilizing stop-motion techniques. The purpose of this study was to evaluate in vivo dynamic kinematics for full range of motion in normal knees using the three-dimensional to two-dimensional registration technique and to compare them with previously reported normal knee kinematics obtained via stop-motion techniques. METHODS Dynamic motion of the right knee was analyzed in 20 healthy volunteers (10 female, 10 male; mean age 37.2 years). Knee motion was observed when subjects squatted from standing with the knee fully extended to maximum flexion. We determined the following parameters: (1) changes to angles of the geometric center axis (GCA) on the tibial axial plane (rotation angle); (2) anteroposterior translations of the medial and lateral ends of the GCA; and (3) motion patterns in each phase during knee flexion. RESULTS All subjects exhibited femoral external rotation (26.1°) relative to the tibia throughout knee flexion. The medial femoral condyle demonstrated anterior translation (5.5 mm) from full extension to 100° flexion, and demonstrated posterior translation (3.9 mm) after 100°, while the lateral femoral condyle demonstrated consistent posterior translation (15.6 mm) throughout knee flexion. All subjects showed medial pivot motion from full extension to nearly 120° flexion. From 120° flexion, bicondylar rollback motion was observed. DISCUSSION Although the behavior of the medial femoral condyle in our analysis differed somewhat from that seen in previous cadaver studies, the results obtained using dynamic analysis were generally equivalent to those obtained in previous studies employing stop-motion techniques. These results provide control data for future dynamic kinematic analyses of pathological knees.
Collapse
Affiliation(s)
- Osamu Tanifuji
- Department of Orthopaedic Surgery, Niigata Medical Center, 3-27-11 Kobari, Nishi-ku, Niigata, Niigata, 950-2022, Japan
| | | | | | | | | | | | | | | |
Collapse
|
40
|
Bae DK, Song SJ, Cho SD. Clinical outcome of total knee arthroplasty with medial pivot prosthesis a comparative study between the cruciate retaining and sacrificing. J Arthroplasty 2011; 26:693-8. [PMID: 20637557 DOI: 10.1016/j.arth.2010.04.022] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2010] [Accepted: 04/20/2010] [Indexed: 02/01/2023] Open
Abstract
The purpose of this study is to evaluate results after total knee arthroplasty using a medial pivot prosthesis with the posterior cruciate ligament (PCL)-retaining and PCL-sacrificing techniques. The PCL was retained in 67 knees and sacrificed in 70 knees. The mean Knee Society knee score increased from 59.6 before surgery to 91.5 at the last follow-up, and the mean function score increased from 53.6 to 85.4. The mean preoperative femorotibial angle was varus 4.1°, which corrected to valgus 5.8° after surgery. The increased knee and function score did not vary significantly between the cruciate-retaining and cruciate-sacrificing groups (P > .108), nor did the mean preoperative and postoperative femorotibial angle (P > .140). The clinical results of total knee arthroplasty with a medial pivot prosthesis were satisfactory, whether the PCL was retained or sacrificed.
Collapse
Affiliation(s)
- Dae Kyung Bae
- Department of Orthopaedic Surgery, School of Medicine, Kyung Hee University, Seoul, South Korea
| | | | | |
Collapse
|
41
|
Belvedere C, Leardini A, Giannini S, Ensini A, Bianchi L, Catani F. Does medio-lateral motion occur in the normal knee? An in-vitro study in passive motion. J Biomech 2011; 44:877-84. [DOI: 10.1016/j.jbiomech.2010.12.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2010] [Revised: 12/03/2010] [Accepted: 12/03/2010] [Indexed: 11/25/2022]
|
42
|
Knee arthroplasty with a medially conforming ball-and-socket tibiofemoral articulation provides better function. Clin Orthop Relat Res 2011; 469:55-63. [PMID: 20700674 PMCID: PMC3008885 DOI: 10.1007/s11999-010-1493-3] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND A knee design with a ball-and-socket articulation of the medial compartment has a femoral rollback profile similar to the native knee. Compared to a conventional, posterior-stabilized knee design, it provides AP stability throughout the entire ROM. However, it is unclear whether this design difference translates to clinical and functional improvement. QUESTIONS/PURPOSES We asked whether the medially conforming ball-and-socket design differences would be associated with (1) improved ROM; and (2) improved American Knee Society, WOMAC, Oxford Knee, SF-36, and Total Knee Function Questionnaire scores compared to a conventional, fixed-bearing posterior-stabilized TKA. PATIENTS AND METHODS We enrolled 82 patients in a single-center, single-blinded, randomized, controlled trial comparing the medially conforming ball-and-socket design knee prosthesis to a posterior-stabilized total knee prosthesis. Our primary end point was ROM. Our secondary end points were American Knee Society, WOMAC, Oxford Knee, SF-36, and Total Knee Function Questionnaire scores. All patients were followed at 1 and 2 years. RESULTS The mean ROM was 100.1° and 114.9° in the posterior-stabilized and medially conforming ball-and-socket groups, respectively. The physical component scores of SF-36 and Total Knee Function Questionnaire were better in the medially conforming ball-and-socket group. We found no difference in American Knee Society, WOMAC, and Oxford Knee scores. CONCLUSIONS Both implant designs similarly relieved pain and improved function. The medially conforming ball-and-socket articulation provided better high-end function as reflected by the Total Knee Function Questionnaire. LEVEL OF EVIDENCE Level I, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Collapse
|
43
|
Wu JL, Hosseini A, Kozanek M, Gadikota HR, Gill TJ, Li G. Kinematics of the anterior cruciate ligament during gait. Am J Sports Med 2010; 38:1475-82. [PMID: 20442323 PMCID: PMC3740375 DOI: 10.1177/0363546510364240] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The function of the anteromedial (AM) and posterolateral (PL) bundles of the anterior cruciate ligament (ACL) during gait has not been reported. HYPOTHESIS The AM and PL bundles have distinct functional behavior during the stance phase of treadmill gait. STUDY DESIGN Descriptive laboratory study. METHODS Three-dimensional models of the knee were created by magnetic resonance images from 8 healthy subjects. The contour of the 2 bundle attachments were constructed on each model. Each bundle was represented by a straight line connecting its tibial and femoral attachment centroids. Next, the knee kinematics during the stance phase of gait was determined with a dual fluoroscopic imaging system. The relative elongation, sagittal plane elevation, coronal plane elevation, and transverse plane deviation of the 2 bundles were measured directly from heel strike to toe-off. RESULTS At heel strike, the AM and PL bundles had first peak elongation of 9% +/- 7% and 9% +/- 13%, respectively. At 50% progress of the stance phase, both bundles were maximally elongated, 12% +/- 7% for the AM bundle and 13% +/- 15% for the PL bundle. No significant difference was found for each bundle between 40% and 60% of the stance phase (P > .05). With increasing knee flexion, the sagittal plane and coronal plane elevations of the 2 bundles decreased, whereas the deviation angles increased. CONCLUSION Both bundles are anisometric and function in a similar manner during the stance phase of gait. They were maximally elongated throughout the midstance where they were stretched maximally to resist anterior tibial translation. CLINICAL RELEVANCE This information can be useful for further improving anatomical ACL reconstructions to better reproduce the 2 bundle functions. It may also be useful for designing postoperative rehabilitation regimens to prevent overstretch of the grafts.
Collapse
Affiliation(s)
- Jia-Lin Wu
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts,Department of Orthopaedic Surgery, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan
| | - Ali Hosseini
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts,Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts
| | - Michal Kozanek
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Hemanth R. Gadikota
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Thomas J. Gill
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Guoan Li
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts,Address correspondence to Guoan Li, PhD, Bioengineering Laboratory, Massachusetts General Hospital/Harvard Medical School, 55 Fruit Street, GRJ 1215, Boston, MA 02114
| |
Collapse
|
44
|
Karachalios T, Roidis N, Giotikas D, Bargiotas K, Varitimidis S, Malizos KN. A mid-term clinical outcome study of the Advance Medial Pivot knee arthroplasty. Knee 2009; 16:484-8. [PMID: 19349182 DOI: 10.1016/j.knee.2009.03.002] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2008] [Revised: 03/08/2009] [Accepted: 03/09/2009] [Indexed: 02/02/2023]
Abstract
The Advance Medial Pivot Total Knee Arthroplasty (Wright Medical Technology, Arlington, Tennessee, USA) has been designed to reproduce modern ideas of knee kinematics. We report a prospective clinical outcome study of 284 arthroplasties in 225 consecutive patients with a mean follow-up of 6.7 years (range 4 to 9 years). For evaluation, both objective and subjective clinical rating systems and serial radiographs were used. At final follow-up, 10 (4.4%) patients (10 knees) only were lost from follow-up and four (1.8%) patients (five knees) had died for reasons unrelated to the surgery with their knees performing well. There was an 82% compliance in the intervals of follow-up evaluation. All patients showed a statistically significant improvement (p=0.01) in the Knee Society clinical rating system, WOMAC questionnaire, SF-12 questionnaire, and Oxford knee score. The majority of patients (92%) were able to perform age-appropriate activities with a mean knee flexion of 117 degrees (range 85 degrees to 135 degrees) at final follow-up. Survival analysis showed a cumulative success rate of 99.1% at 5 years. Two (0.7%) arthoplasties, in which patient selection and surgical errors were identified, were revised due to aseptic loosening, one due to infection and one due to a traumatic dislocation. This study demonstrates satisfactory mid-term clinical results for this knee design.
Collapse
Affiliation(s)
- Theofilos Karachalios
- Department of Orthopaedics, School of Medicine, Faculty of Health Sciences, University of Thessalia, Larissa, Hellenic Republic, Greece.
| | | | | | | | | | | |
Collapse
|
45
|
Helical axis calculation based on Burmester theory: experimental comparison with traditional techniques for human tibiotalar joint motion. Med Biol Eng Comput 2009; 47:1207-17. [DOI: 10.1007/s11517-009-0522-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2009] [Accepted: 08/02/2009] [Indexed: 02/04/2023]
|
46
|
Relationship between the surgical epicondylar axis and the articular surface of the distal femur: an anatomic study. Knee Surg Sports Traumatol Arthrosc 2008; 16:674-82. [PMID: 18478201 DOI: 10.1007/s00167-008-0551-9] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2007] [Accepted: 04/08/2008] [Indexed: 10/22/2022]
Abstract
Many authors presented the epicondylar axis as the fixed axis of rotation of the femoral condyles during flexion of the knee. Positioning of the femoral component of a total knee arthroplasty (TKA) based on the epicondyles has been proposed. This work is a critical analysis of this concept. Metallic bodies were inserted at the level of collateral ligament insertions on 16 dried femurs, allowing us to locate the surgical epicondylar axis. The dried femurs were studied using standard radiographs and CT-scan. CT cuts were made perpendicular to the epicondylar axis. The medial mechanical femoral angle and the epicondylar angle were measured on the radiographs. The posterior and distal epiphyseal rotations relative to the epicondylar axis (Posterior Condylar Angle, PCA, and Distal Condylar Angle, DCA, respectively) were measured on the CT-scans. PCA and DCA values were compared. The centre of the posterior femoral condyles was located on sagittal reconstructions using the tangent method and was confirmed with circular templates, and then compared to the location of the epicondyles. Circle-fitting of the entire femoral condylar contours centred on the epicondyles was also tried. The mechanical femoral axis was nearly perpendicular to the epicondylar axis but with important variations. The average PCA and DCA were 1.9 degrees +/- 1.8 degrees and 3.1 degrees +/- 2.1 degrees , respectively. No relationship could be established between the mechanical femoral angle and the PCA. The individual differences between the PCA and the DCA averaged 2.2 degrees . A significant distance was found between the centre of the condylar contours and the epicondyles: 6.5 mm in average on the lateral side (range 2.3-11.3 mm) and 8.4 mm on the medial side (range 4.0-11.6 mm). Circle-fitting of the entire medial or lateral femoral condylar contours centred on the epicondyles was not possible. The centre of the posterior femoral condyles is significantly different from the epicondylar axis, thus refuting the conclusions of previous authors. Furthermore, considering the differences between the distal and posterior condylar angles shown here, as well as the difficulty of repeatably locating the epicondyles during surgery, using the epicondylar axis as the only landmark to position the femoral component during a first intention TKA is not recommended. The surgical epicondylar axis does not appear to be an adequate basis for the understanding of the shape of the distal femur.
Collapse
|
47
|
Amin A, Al-Taiar A, Sanghrajka AP, Kang N, Scott G. The early radiological follow-up of a medial rotational design of total knee arthroplasty. Knee 2008; 15:222-6. [PMID: 18280168 DOI: 10.1016/j.knee.2008.01.004] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2007] [Revised: 12/26/2007] [Accepted: 01/07/2008] [Indexed: 02/02/2023]
Abstract
The objective of this study was to investigate the hypothesis that the increased constraint of a medial rotational knee promotes earlier loosening of the prosthesis. All patients with a Freeman-Samuelson 1000 knee arthroplasty (medial pivot design), (group 1), or a Freeman-Samuelson Modular knee arthroplasty, (group 2), with a minimum follow-up of 2 years (mean follow-up 4 years) were identified from our unit's arthroplasty database, and matched as closely as possible for age, length of follow-up and pre-operative diagnosis. Standardised anteroposterior and lateral radiographs were analysed for component migration and radiolucent lines as recommended by the Knee Society. There were 48 knees in each group. There were no failures in group 2. There was one failure requiring revision of the tibial component in group 1. There was no significant difference in overall radiolucent line scores between the two groups (p=0.66, at 5 years). Progressive radiolucent lines were detected in similar numbers of patients in both groups (FS1000 8/48, FSM 7/48, p=0.84). Our early radiological survey suggests that the increased constraint of the medial pivot knee prosthesis does not result in an increased incidence of radiographic loosening.
Collapse
Affiliation(s)
- A Amin
- Royal London Hospital, Whitechapel Road, Whitechapel E1 1BB, United Kingdom.
| | | | | | | | | |
Collapse
|
48
|
Koo S, Andriacchi TP. The knee joint center of rotation is predominantly on the lateral side during normal walking. J Biomech 2008; 41:1269-73. [PMID: 18313060 DOI: 10.1016/j.jbiomech.2008.01.013] [Citation(s) in RCA: 84] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2007] [Revised: 01/14/2008] [Accepted: 01/17/2008] [Indexed: 11/17/2022]
Abstract
The purpose of this study was to test the hypothesis of whether the center of rotation (COR) in the transverse plane of the knee is in the medial side during normal walking in a manner similar to that previously described during non-ambulatory activities. The kinematics for normal knees was obtained from 46 knees during normal walking using the point cluster technique. The COR of the medial-lateral axis of the femur relative to the tibia was determined during the stance phase of walking. The hypothesis that the COR is in the medial side during stance was not supported by this study. The average COR during the stance phase of walking was in the lateral compartment for all 46 knees. In addition, the instantaneous COR occurred on the medial side on average <25% of the time during the stance phase. Thus, while the COR is predominantly on the lateral side of the knee during walking, the normal function of the knee during walking is associated with both lateral and medial pivoting. These results also demonstrate the importance of describing knee kinematics in the context of a specific activity or the constraints of the test conditions.
Collapse
Affiliation(s)
- Seungbum Koo
- Department of Mechanical Engineering, Durand Building, Room 205, Stanford University, Stanford, CA 94305-4038, USA.
| | | |
Collapse
|
49
|
Helical axes of skeletal knee joint motion during running. J Biomech 2008; 41:1632-8. [PMID: 18457841 DOI: 10.1016/j.jbiomech.2008.03.018] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2004] [Revised: 03/15/2008] [Accepted: 03/17/2008] [Indexed: 11/21/2022]
|
50
|
Fixed-bearing or mobile-bearing total knee arthroplasty? A review of the recent literature. ACTA ACUST UNITED AC 2007. [DOI: 10.1097/bco.0b013e3280119624] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|