1
|
Zhu QJ, Xing XY, Zhu MH, Ma L, Yuan Y, Song E. Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study. BMC Ophthalmol 2022; 22:463. [PMID: 36451125 PMCID: PMC9714062 DOI: 10.1186/s12886-022-02698-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 11/21/2022] [Indexed: 12/05/2022] Open
Abstract
BACKGROUND To verify the accuracy and stability of the prediction formula based on the ciliary sulcus diameter and lens thickness and to analyse factors influencing the prediction results. METHODS In total, 925 eyes from 506 subjects were enrolled in this prospective study between July 1, 2020, and June 30, 2021. Subjects were divided into four seasons, each spanning three months. The target vault was set to be between 300 μm and 700 μm according the prediction formula. The actual vault was measured one month postoperatively. The Bland-Altman test, 95% confidence intervals (95% CI) and 95% limits of agreement (95% LoA) were used to evaluate the agreement between the predicted vault and the actual vault. Eyes with absolute prediction errors greater than 300 μm were further analysed. RESULTS The mean predicted vaults for the four seasons were 503 ± 99, 494 ± 96, 481 ± 92 and 502 ± 93 μm, while the mean actual vaults were 531 ± 189, 491 ± 179, 464 ± 179 and 529 ± 162 μm, respectively. The predicted and actual vaults of the overall subjects were 493 ± 95 and 500 ± 180 μm, respectively. Of the 925 eyes, 861 eyes (93.08%), 42 eyes (4.54%), and 22 eyes (2.38%) showed a normal vault, high vault, and low vault, respectively. Bland-Altman plots showed that the mean difference between the actual vault and predicted vault overall (± 95% LoA) was 6.43 ± 176.2 μm (-339 to 352 μm). Three UBM features may lead to large prediction errors (more than 300 μm): wide iris-ciliary angle (ICA), iris concavity and anteriorly positioned ciliary body. CONCLUSIONS This study demonstrated the accuracy and stability of the prediction formula through the validation of a large sample size and a long time span. Wide ICA, iris concavity and anteriorly positioned ciliary body may have an effect on vault.
Collapse
Affiliation(s)
- Qiu-Jian Zhu
- grid.452666.50000 0004 1762 8363Department of Ophthalmology, The Second Affiliated Hospital of Soochow University, Suzhou, China ,grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | | | - Man-Hui Zhu
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - Lie Ma
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - You Yuan
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - E. Song
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| |
Collapse
|
2
|
Abstract
PURPOSE We conducted a systematic search of literature to understand the various methods of imaging of the ciliary body. METHODS PubMed, Science Direct, Cochrane Library and Google Scholar were searched comprehensively and systematically to find studies related to the various modalities of ciliary body imaging. RESULTS The various ciliary body parameters that have been described are Ciliary body thickness, Ciliary body length, ciliary muscle thickness, ciliary process length, ciliary muscle length, ciliary muscle anterior length, trabecular ciliary process distance and Iris ciliary process distance. The various angles which have been measured, which mostly have a significance in Primary angle closure glaucoma (PACG) are Iris ciliary angle, Trabecular ciliary angle, scleral ciliary process angle. Various authors have defined them in various ways with subtle differences. Plateau iris and PACG mechanisms, not forgetting malignant glaucoma are better understood with imaging of the ciliary body using the ultrasound biomicroscopy (UBM). The anterior segment optical coherence tomography (ASOCT) imaging of the ciliary body has been described albeit with its own disadvantages. A few other fields dependant on the importance of ciliary body imaging are intravitreal injections, pars plana vitrectomy, measurements for implantable collamer lens (ICL) and of utmost importance, the differentiating features of ciliary body masses. CONCLUSION The UBM is still preferred over the ASOCT for imaging of the ciliary body. A lot of lacunae of knowledge still exists and consensus has to be reached on defining all the parameters universally. Future studies will be able to shed more light on the role of the ciliary body in the many ocular disorders mentioned in this review.
Collapse
Affiliation(s)
| | - Sirisha Senthil
- VST Centre for Glaucoma Services, L V Prasad Eye Institute, Hyderabad, India
| |
Collapse
|
3
|
Chen Q, Tan W, Lei X, Pan C, Jin L, Zeng Q, Wang Z. Clinical Prediction of Excessive Vault After Implantable Collamer Lens Implantation Using Ciliary Body Morphology. J Refract Surg 2021; 36:380-387. [PMID: 32521025 DOI: 10.3928/1081597x-20200513-02] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Accepted: 05/13/2020] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine the factors related to the ciliary body that are predictive of outcomes of excessive vault (> 1,000 µm) after Implantable Collamer Lens (ICL V4c; STAAR Surgical) implantation. METHODS In this retrospective case-control study, 27 eyes of 27 patients who presented with excessive vault (> 1,000 µm) following implantation of an ICL V4c were matched in a 1:2 ratio with those who presented with a normal vault (250 to 1,000 µm) on white-to-white distance, anterior chamber depth, and ICL size. The preoperative biometric parameters and clinical outcomes were compared between the two groups. The relationship between the postoperative vault and various variables was assessed by multiple linear regression analysis. Conditional logistic regression models were used to estimate odds ratios (ORs) and 95% CIs for excessive vault. RESULTS The vault value 1 month postoperatively was associated with preoperative anterior chamber volume, iris-ciliary angle, and crystalline lens rise (P < .05). In the conditional regression logistic analysis, every 1° reduction in iris-ciliary angle was associated with 4% increased odds of vault greater than 1,000 µm (OR = 0.96; 95% CI = 0.93 to 0.99; P < .001) and the anteriorly positioned ciliary body was associated with an increased risk of excessive vault after ICL implantation (OR = 3.57; 95% CI = 1.67 to 7.63; P < .001). In the excessive vault group, 1 eye underwent the ICL extraction and 3 eyes had an ICL exchange for a smaller ICL. After the ICL exchange, the mean value of postoperative vault decreased from 1,525.67 ± 468.22 to 810.33 ± 254.92 µm. CONCLUSIONS Eyes with an anteriorly positioned ciliary body were associated with a higher rate of excessive vault after ICL implantation, so the size of the ICL may need to be adjusted in these patients. Assessment of ciliary body characteristics adds significant information to the prediction of excessive vault after surgery. [J Refract Surg. 2020;36(6):380-387.].
Collapse
|
4
|
Mannino G, Abdolrahimzadeh B, Calafiore S, Anselmi G, Mannino C, Lambiase A. A review of the role of ultrasound biomicroscopy in glaucoma associated with rare diseases of the anterior segment. Clin Ophthalmol 2016; 10:1453-9. [PMID: 27536058 PMCID: PMC4975163 DOI: 10.2147/opth.s112166] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Ultrasound biomicroscopy is a non-invasive imaging technique, which allows high-resolution evaluation of the anatomical features of the anterior segment of the eye regardless of optical media transparency. This technique provides diagnostically significant information in vivo for the cornea, anterior chamber, chamber angle, iris, posterior chamber, zonules, ciliary body, and lens, and is of great value in assessment of the mechanisms of glaucoma onset. The purpose of this paper is to review the use of ultrasound biomicroscopy in the diagnosis and management of rare diseases of the anterior segment such as mesodermal dysgenesis of the neural crest, iridocorneal endothelial syndrome, phakomatoses, and metabolic disorders.
Collapse
Affiliation(s)
- Giuseppe Mannino
- Ophthalmology Unit, Saint Andrea Hospital, Department of Neurosciences, Mental Health and Sense Organs, University of Rome "Sapienza", Rome, Italy
| | | | - Silvia Calafiore
- Ophthalmology Unit, Saint Andrea Hospital, Department of Neurosciences, Mental Health and Sense Organs, University of Rome "Sapienza", Rome, Italy
| | - Gianmario Anselmi
- Ophthalmology Unit, Saint Andrea Hospital, Department of Neurosciences, Mental Health and Sense Organs, University of Rome "Sapienza", Rome, Italy
| | - Cristina Mannino
- Ophthalmology Unit, Saint Andrea Hospital, Department of Neurosciences, Mental Health and Sense Organs, University of Rome "Sapienza", Rome, Italy
| | - Alessandro Lambiase
- Department of Sense Organs, Ophthalmology Unit, University of Rome "Sapienza", Rome, Italy
| |
Collapse
|
5
|
|
6
|
Mizoguchi T, Ozaki M, Wakiyama H, Ogino N. Plateau iris in Japanese patients with primary angle closure and primary angle closure glaucoma. Clin Ophthalmol 2015; 9:1159-63. [PMID: 26170608 PMCID: PMC4494604 DOI: 10.2147/opth.s80724] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Purpose To determine the prevalence of plateau iris in Japanese patients with primary angle closure (PAC) and primary angle closure glaucoma (PACG) and analyze the biometric parameters in patients with plateau iris using ultrasound biomicroscopy (UBM). Methods In this cross-sectional observational study, subjects aged >50 years with PAC and PACG who had previously undergone a patent laser peripheral iridotomy underwent UBM in one eye. UBM images were qualitatively analyzed using standardized criteria. Plateau iris in a quadrant was defined by anteriorly directed ciliary body, absent ciliary sulcus, steep iris root from its point of insertion followed by a downward angulation, flat iris plane, and irido-angle contact. At least two quadrants had to fulfill these UBM criteria for an eye to be classified as having plateau iris. A-scan biometry was used to measure anterior segment parameters. Results Ninety-one subjects with PAC (58 subjects) or PACG (33 subjects) and 68 normal controls were recruited. The mean (standard deviation) ages of PAC and PACG patients and normal controls were 73.5 (6.2) and 72.6 (7.3), respectively. Based on UBM criteria, plateau iris was found in 16 eyes (17.6%) of 91 eyes. In these 16 eyes, quadrant-wise analysis showed ten eyes (62.5%) had plateau iris in two quadrants; four eyes (25%) had plateau iris in three quadrants; and two eyes (12.5%) had plateau iris in four quadrants. Anterior chamber depth, lens thickness, axial length, lens position, and relative lens position were not statistically significant between the group having plateau iris and that not having plateau iris, respectively. Conclusion Approximately 20% of Japanese subjects with PAC and PACG with a patent laser peripheral iridotomy were found to have plateau iris on UBM. No morphological difference was noted in the anterior segment of the eye between those with or without plateau iris.
Collapse
Affiliation(s)
| | - Mineo Ozaki
- Ozaki Eye Clinic Miyazaki, Japan ; Department of Ophthalmology, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan
| | - Harumi Wakiyama
- Mizoguchi Eye Clinic, Nagasaki, Japan ; The Japanese Red Cross Nagasaki Genbaku Hospital, Nagasaki, Japan
| | - Nobuchika Ogino
- Mizoguchi Eye Clinic, Nagasaki, Japan ; Nishigaki Eye Clinic, Nagoya, Japan
| |
Collapse
|
7
|
Abstract
This article summarizes the physics, technology and clinical application of ultrasound biomicroscopy (UBM) and optical coherence tomography (OCT) for assessment of the anterior segment in glaucoma. UBM systems use frequencies ranging from approximately 35 to 80 MHz, as compared with typical 10-MHz systems used for general-purpose ophthalmic imaging. OCT systems use low-coherence, near-infrared light to provide detailed images of anterior segment structures at resolutions exceeding that of UBM. Both technologies allow visualization of the iridocorneal angle and, thus, can contribute to the diagnosis and management of glaucoma. OCT systems are advantageous, being noncontact proceedures and providing finer resolution than UBM, but UBM systems are superior for the visualization of retroiridal structures, including the ciliary body, posterior chamber and zonules, which can provide crucial diagnostic information for the assessment of glaucoma.
Collapse
Affiliation(s)
- Roxana Ursea
- Assistant Professor of Ophthalmology, Director, Cornea and Refractive Surgery Division, Department of Ophthalmology, University of Arizona, 655 N. Alvernon Way, Suite 108, Tucson, AZ 85711, USA, Tel.: +1 520 322 3800 ext. 204
| | | |
Collapse
|
8
|
Smith SD, Singh K, Lin SC, Chen PP, Chen TC, Francis BA, Jampel HD. Evaluation of the Anterior Chamber Angle in Glaucoma. Ophthalmology 2013; 120:1985-97. [DOI: 10.1016/j.ophtha.2013.05.034] [Citation(s) in RCA: 74] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2013] [Revised: 05/02/2013] [Accepted: 05/06/2013] [Indexed: 01/19/2023] Open
|
9
|
Kumar G, Bali SJ, Panda A, Sobti A, Dada T. Prevalence of plateau iris configuration in primary angle closure glaucoma using ultrasound biomicroscopy in the Indian population. Indian J Ophthalmol 2012; 60:175-8. [PMID: 22569376 PMCID: PMC3361810 DOI: 10.4103/0301-4738.95865] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Purpose: To report the prevalence of plateau iris in patients with primary angle closure glaucoma (PACG), in North India. Materials and Methods: The patients with PACG, attending the glaucoma services at a tertiary care center in North India were included in the study. All patients had undergone Nd-YAG laser peripheral iridotomy at least four weeks prior to inclusion in the study. Four weeks prior to inclusion in the study, none of the patients had used pilocarpine. Ultrasound Biomicroscopy (UBM) images were qualitatively evaluated and plateau iris configuration was defined in an eye if the following criteria were fulfilled in two or more quadrants: anteriorly directed ciliary process supporting the peripheral iris, steep rise of iris root from its point of insertion followed by a downward angulation from the corneoscleral wall, absent ciliary sulcus, and iridotrabecular contact in the same quadrant. Results: One hundred and one eyes were included in the study. There were 63 (62.4%) females and 38 (37.6%) males. The mean age of the patients was 57.8 ± 9.5 years (range: 42 to 78 years). The mean axial length in the study population was 22.2 ± 1.1 mm. The mean spherical equivalent refraction was 0.06 ± 1.12 D. The mean intraocular pressure was 18.5 ± 4.7 mmHg (range: 12 – 24 mmHg). Twenty-nine (28.7%) subjects were diagnosed with plateau iris on the basis of above-defined criteria. Of the 29 eyes, 18 (62.1%) subjects had plateau iris in two quadrants, nine (31.03%) in three quadrants, and two (6.8%) had this configuration in all the four quadrants. Conclusions: Approximately 30% of the eyes with PACG had plateau iris on UBM. Plateau iris was very often the cause for residual angle closure following laser peripheral iridotomy in Indian eyes with PACG.
Collapse
Affiliation(s)
- Gaurav Kumar
- Department of Ophthalmology, Glaucoma facility, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | | | | | | | | |
Collapse
|
10
|
|
11
|
Plateau iris in open-angle glaucoma? J Glaucoma 2012; 21:431; author reply 431-2. [PMID: 22366699 DOI: 10.1097/ijg.0b013e31824c7846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
12
|
|
13
|
Kumar RS, Baskaran M, Chew PTK, Friedman DS, Handa S, Lavanya R, Sakata LM, Wong HT, Aung T. Prevalence of Plateau Iris in Primary Angle Closure Suspects. Ophthalmology 2008; 115:430-4. [PMID: 17900691 DOI: 10.1016/j.ophtha.2007.07.026] [Citation(s) in RCA: 95] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2007] [Revised: 07/08/2007] [Accepted: 07/24/2007] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To determine the prevalence of plateau iris in a cohort of primary angle closure suspects (PACSs) using ultrasound biomicroscopy (UBM). DESIGN Cross-sectional observational study. PARTICIPANTS Subjects over the age of 50 years diagnosed as PACSs. INTERVENTION Subjects were randomized to undergo laser peripheral iridotomy (LPI) in one eye. Ultrasound biomicroscopy was performed before and a week after LPI. MAIN OUTCOME MEASURES Ultrasound biomicroscopy images were qualitatively assessed using standardized criteria. Plateau iris was defined in a quadrant by the presence of an anteriorly directed ciliary body, an absent ciliary sulcus, a steep iris root from its point of insertion followed by a downward angulation from the corneoscleral wall, presence of a central flat iris plane, and irido-angle contact. At least 2 quadrants had to fulfil the above criteria for an eye to be defined as plateau iris. RESULTS Two hundred five subjects were enrolled; UBM images of 167 subjects were available for analysis. Plateau iris was found in 54 of 167 (32.3%) PACS eyes after LPI. Quadrantwise analysis showed that 44 of 167 (26.3%) eyes had plateau iris in 1 quadrant, 36 (21.5%) in 2 quadrants, 16 (9.5%) in 3 quadrants, and 2 (1.2%) in all 4 quadrants. Plateau iris was most commonly observed in the superior and inferior quadrants. CONCLUSIONS Using standardized UBM criteria, plateau iris was found in about a third of PACS eyes after LPI. Prospective longitudinal studies are required to determine the clinical significance of this finding for the management of PACSs.
Collapse
|