• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4643668)   Today's Articles (342)   Subscriber (50586)
For: Ichikawa S, Linneweber J, Motomura T, Ishitoya H, Watanabe K, Ashizawa S, Murai N, Nishimura I, Sumikura H, Glueck JA, Shinohara T, Oestmann DJ, Nosé Y. In vivo evaluation of the NEDO biventricular assist device with an RPM dynamic impeller suspension system. ASAIO J 2004;49:578-82. [PMID: 14524568 DOI: 10.1097/01.mat.0000084104.91081.7b] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
Number Cited by Other Article(s)
1
Biventricular Assist Devices: A Technical Review. Ann Biomed Eng 2011;39:2313-28. [DOI: 10.1007/s10439-011-0348-8] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2011] [Accepted: 06/28/2011] [Indexed: 01/16/2023]
2
Saeed D, Fukamachi K. In Vivo Preclinical Anticoagulation Regimens After Implantation of Ventricular Assist Devices. Artif Organs 2009;33:491-503. [DOI: 10.1111/j.1525-1594.2009.00733.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
3
Motomura T, Okubo H, Oda T, Ogawa D, Okahisa T, Igo S, Shinohara T, Yamamoto Y, Noguchi C, Ishizuka T, Okamoto E, Nosé Y. Ten-year NEDO BVAD development program: moving forward to the clinical arena. ASAIO J 2006;52:378-85. [PMID: 16883116 DOI: 10.1097/01.mat.0000225263.48393.93] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
4
Yamanaka H, Rosenberg G, Weiss WJ, Snyder AJ, Zapanta CM, Siedlecki CA. Multiscale analysis of surface thrombosis in vivo in a left ventricular assist system. ASAIO J 2006;51:567-77. [PMID: 16322720 DOI: 10.1097/01.mat.0000181707.06225.a0] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]  Open
5
Asai T, Watanabe K, Ito S, Tsujimura S, Motomura T, Shinohara T, Glueck JA, Nosé Y. Real-time studies of the pivot bearings in the NEDO Gyro PI-710 centrifugal blood pump. Artif Organs 2005;28:899-903. [PMID: 15384995 DOI: 10.1111/j.1525-1594.2004.00074.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
6
Watanabe K, Asai T, Ichikawa S, Motomura T, Hata A, Ito S, Shinohara T, Tsujimura S, Oestmann DJ, Nosé Y. Development of a flexible inflow cannula with titanium inflow tip for the NEDO biventricular assist device. ASAIO J 2004;50:381-6. [PMID: 15307553 DOI: 10.1097/01.mat.0000132555.85820.8e] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA