Ferraro EL, Zura N, Abdelmalak BB, Galway U, Benninger MS, Bryson PC. Cadaveric Study on the Safety of High-Flow Nasal Oxygen in Laser Microlaryngeal Surgery.
Laryngoscope 2024. [PMID:
39243216 DOI:
10.1002/lary.31733]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Revised: 06/30/2024] [Accepted: 07/24/2024] [Indexed: 09/09/2024]
Abstract
INTRODUCTION
High-flow nasal oxygen (HFNO), or transnasal humidified rapid-insufflation ventilatory exchange (THRIVE), is a technique providing apneic oxygenation and a degree of ventilation during microlaryngeal surgery. Its use with laser has been questioned due to concern for airway fire. For fire to occur, a triad of ignition source, oxidizer, and fuel source must be present. By using HFNO and eliminating an endotracheal tube (fuel source), it is hypothesized that airway fire risk is minimal. We tested this theory with human cadavers using HFNO with increasing levels of FiO2 while performing microlaryngeal laser surgery.
METHODS
HFNO was placed on two cadavers, and oxygen was administered at incrementally increasing fraction of inspired oxygen (FiO2) concentrations (30%-100%). Laryngeal microsurgery was conducted with CO2 and KTP lasers applied for 30 s. Oxygen readings were taken at several anatomic locations along the body assessing oxygen concentrations in correlation with increasing FiO2 administration.
RESULTS
The use of CO2 and KTP laser on cadaveric vocal folds produced char but no spark or airway fire at any of the tested oxygen concentrations. Apart from the mouth, there was minimal increase in oxygen levels at the surrounding anatomic sites despite elevating FiO2 levels.
CONCLUSION
HFNO may be safe to use during microlaryngeal laser surgery. By eliminating the endotracheal tube as a fuel source, risk of airway fire may be negligible. Our study safely applied CO2 and KTP lasers for an uninterrupted 30 s with HFNO at 70 L/min and 100% FiO2 producing no spark or fire.
LEVEL OF EVIDENCE
NA Laryngoscope, 2024.