1
|
AlMakadma HA, Reed BF, Sanford CA. An Absorbance Peak Template for Clinical Assessment of Sound Conduction in Newborn Ears. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2023; 66:5152-5168. [PMID: 37971558 DOI: 10.1044/2023_jslhr-23-00122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
PURPOSE Power absorbance measures recorded over a wide range of frequencies allow for clinical inferences about the outer/middle ears' acoustic mechanics. A frequency-dependent feature in the newborn wideband absorbance response, the prominent mid-frequency absorbance peak, has been linked to middle-ear resonance. However, current normative methods were not designed to assess subtle changes in such features. This work aims to develop and validate an absorbance peak template (APT) for assessment of absorbance peaks in newborns. Additional objectives are to compare test performance of absorbance peaks and APTs to existing normative methods, to demonstrate APT-based methods for categorization of abnormal absorbance peaks, and to describe absorbance peak test-retest variability. METHOD Peak absorbance and peak frequency were analyzed in a training data set (490 measurements in 84 newborn ears who passed transient evoked otoacoustic emissions [TEOAEs] screenings), and an APT was developed by computing normal limits on these two absorbance peak variables. Split-set analysis evaluated the reproducibility of APT, and test-retest analysis was performed. Test performance analysis, conveyed by area under the receiver operating characteristic curve (AROC) and 95% confidence intervals (CIs), compared absorbance peak variables to absorbance area indices (AAIs) in a validation data set (359 ears that passed distortion-product OAE [DPOAE] screening and 64 ears that failed). APT-based assessment paradigms for normal and abnormal ears were compared to the common absorbance normative range paradigm. RESULTS Split-set analysis demonstrated a good reproducibility of APT, and test-retest of absorbance peak variables showed that they were stable measures for clinical assessment. Test performance of peak absorbance (AROC = 0.83; 95% CI [0.77, 0.88]) was comparable to the top-performing AAI variables (AROC = 0.85; 95% CI [0.80, 0.90]). APT-based assessment categorized measurements based on their peak absorbance and peak frequency and enhanced the detection of subtle frequency changes that were missed by the normative range method. CONCLUSION Analysis of absorbance peaks guided by APT has the potential to simplify and improve assessments of sound conduction pathways in newborn ears and can be used together with or in-place of current methods for analysis of wideband absorbance data.
Collapse
Affiliation(s)
- Hammam A AlMakadma
- Department of Otolaryngology-HNS and Communicative Disorders, School of Medicine, University of Louisville, Louisville, KY
| | - Beth F Reed
- Penn State Health Milton S. Hershey Medical Center, Hershey, PA
| | - Chris A Sanford
- Department of Communication Sciences and Disorders, College of Health, Idaho State University, Pocatello
| |
Collapse
|
2
|
Sun J, Horton NJ, Voss SE. Absorbance Measurements From Normal-hearing Ears in the National Health and Nutrition Examination Survey, 2015-2016 and 2017-2020. Ear Hear 2023; 44:1282-1288. [PMID: 36991532 PMCID: PMC10440228 DOI: 10.1097/aud.0000000000001358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/31/2023]
Abstract
OBJECTIVE To summarize absorbance and impedance angles from normal-hearing ears within the 2015-2016 and 2017-2020 US National Health and Nutrition Examination Surveys (NHANES). DESIGN Two publicly available NHANES datasets were analyzed. Ears meeting criteria for normal hearing and valid absorbance and impedance angle measurements were identified. Measurements were summarized via descriptive statistics within categories of age cohort, race/ethnicity cohort, sex (male, female), and ear (left, right). RESULTS A total of 7029 ears from 4150 subjects, ages 6 to 80 years, met inclusion criteria. Differences between subgroups within all categories (age, race/ethnicity, sex, and ear) were fractions of the sample SDs. The largest differences occurred between age cohorts younger than 20 years. CONCLUSIONS The NHANES absorbance and impedance angle measurements are consistent with published literature. These results demonstrate that trained professionals, using the Titan instrument in a community setting inclusive of all demographics, produce comparable measurements to those in laboratory settings.
Collapse
Affiliation(s)
- Jiayi Sun
- Picker Engineering Program, Smith College, Northampton, 01063, MA, USA
| | - Nicholas J. Horton
- Department of Mathematics and Statistics, Amherst College, Amherst, 01002, MA, USA
| | - Susan E. Voss
- Picker Engineering Program, Smith College, Northampton, 01063, MA, USA
| |
Collapse
|
3
|
AlMakadma H, Aithal S, Aithal V, Kei J. Use of Wideband Acoustic Immittance in Neonates and Infants. Semin Hear 2023; 44:29-45. [PMID: 36925658 PMCID: PMC10014211 DOI: 10.1055/s-0043-1764200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2023] Open
Abstract
With widespread agreement on the importance of early identification of hearing loss, universal newborn hearing screening (UNHS) has become the standard of care in several countries. Despite advancements in screening technology, UNHS and early hearing detection and intervention programs continue to be burdened by high referral rates of false-positive cases due to temporary obstruction of sound in the outer/middle ear at birth. A sensitive adjunct test of middle ear at the time of screening would aid in the interpretation of screening outcomes, minimize unnecessary rescreens, and prioritize referral to diagnostic assessment for infants with permanent congenital hearing loss. Determination of middle ear status is also an important aspect of diagnostic assessment in infants. Standard single-frequency tympanometry used to determine middle ear status in infants is neither efficient nor accurate in newborns and young infants. A growing body of research has demonstrated the utility of wideband acoustic immittance (WAI) testing in both screening and diagnostic settings. Wideband power absorbance (WBA), a WAI measure, has been shown to be more sensitive than tympanometry in the assessment of outer/middle ear function in newborns. Furthermore, age-graded norms also support successful application of WBA in young infants. Despite its merits, uptake of this technology is low among pediatric audiologists and hearing screening health workers. This report describes normative data, methods for assessment and interpretation of WBA, test-retest variations, and other factors pertinent to clinical use of WAI in newborns and infants. Clinical cases illustrate the use of WAI testing in newborn and infant hearing assessment.
Collapse
Affiliation(s)
- Hammam AlMakadma
- Department of Otolaryngology and Communicative Disorders, School of Medicine, University of Louisville, Louisville, Kentucky
| | - Sreedevi Aithal
- Hearing Research Unit for Children, School of Health and Rehabilitative Sciences, The University of Queensland, Queensland, Australia.,Department of Audiology, Townsville University Hospital, Townsville, Australia
| | - Venkatesh Aithal
- Hearing Research Unit for Children, School of Health and Rehabilitative Sciences, The University of Queensland, Queensland, Australia.,Department of Audiology, Townsville University Hospital, Townsville, Australia
| | - Joseph Kei
- Hearing Research Unit for Children, School of Health and Rehabilitative Sciences, The University of Queensland, Queensland, Australia
| |
Collapse
|
4
|
Shahnaz N, AlMakadma H, Sanford CA. The Rise and Fall of Aural Acoustic Immittance Assessment Tools. Semin Hear 2023; 44:5-16. [PMID: 36925655 PMCID: PMC10014212 DOI: 10.1055/s-0043-1764139] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2023] Open
Abstract
Clinical assessment of middle ear function has undergone multiple transformations and developments since the first acoustic impedance measurements were made in human ears nearly a century ago. The decades following the development of the first acoustic impedance bridge by Metz in 1946 witnessed a series of technological advancements leading to the widespread use of single-frequency admittance tympanometry in the 1960s. In the 1970s, multi-frequency and multi-component tympanometry (MFT) emerged for clinical use, allowing for a better understanding of the middle ear acoustic-mechanical response at frequencies between 200 and 2,000 Hz. MFT has not gained widespread clinical adoption despite its advantages over single-frequency tympanometry. More recent technological developments enabled assessment for frequencies greater than 2,000 Hz, leading to the advent of wideband acoustic immittance measures with capabilities for comprehensive assessment of middle ear acoustic mechanics, and a great potential for use of acoustic immittance testing in various diagnostic practices. This article reviews important historical markers in the development and operation of middle ear assessment tools and analysis methods. Technical and clinical factors underlying the emergence and adoption of different acoustic immittance tests as a standard of clinical practice are described. In addition, we discuss the likelihood for widespread adoption of wideband acoustic immittance and wideband tympanometry in future clinical practice.
Collapse
Affiliation(s)
- Navid Shahnaz
- School of Audiology and Speech Sciences, University of British Columbia, Vancouver, Canada
- Address for correspondence Navid Shahnaz, Ph.D. School of Audiology and Speech Sciences, Faculty of Medicine, University of British Columbia2177 Wesbrook Mall, Friedman Building, Vancouver, British Columbia V6T 1Z3Canada
| | - Hammam AlMakadma
- Department of Otolaryngology and Communicative Disorders, School of Medicine, University of Louisville, Louisville, Kentucky
| | - Chris A. Sanford
- Department of Communication Sciences and Disorders, College of Health, Idaho State University, Pocatello, Idaho
| |
Collapse
|
5
|
Preserving Wideband Tympanometry Information With Artifact Mitigation. Ear Hear 2022; 43:563-576. [PMID: 34387582 PMCID: PMC8855961 DOI: 10.1097/aud.0000000000001117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Absorbance measured using wideband tympanometry (WBT) has been shown to be sensitive to changes in middle and inner ear mechanics, with potential to diagnose various mechanical ear pathologies. However, artifacts in absorbance due to measurement noise can obscure information related to pathologies and increase intermeasurement variability. Published reports frequently present absorbance that has undergone smoothing to minimize artifact; however, smoothing changes the true absorbance and can destroy important narrow-band characteristics such as peaks and notches at different frequencies. Because these characteristics can be unique to specific pathologies, preserving them is important for diagnostic purposes. Here, we identify the cause of artifacts in absorbance and develop a technique to mitigate artifacts while preserving the underlying WBT information. DESIGN A newly developed Research Platform for the Interacoustics Titan device allowed us to study raw microphone recordings and corresponding absorbances obtained by WBT measurements. We investigated WBT measurements from normal hearing ears and ears with middle and inner ear pathologies for the presence of artifact and noise. Furthermore, it was used to develop an artifact mitigation procedure and to evaluate its effectiveness in mitigating artifacts without distorting the true WBT information. RESULTS We observed various types of noise that can plague WBT measurements and that contribute to artifacts in computed absorbances, particularly intermittent low-frequency noise. We developed an artifact mitigation procedure that incorporates a high-pass filter and a Tukey window. This artifact mitigation resolved the artifacts from low-frequency noise while preserving characteristics in absorbance in both normal hearing ears and ears with pathology. Furthermore, the artifact mitigation reduced intermeasurement variability. CONCLUSIONS Unlike smoothing algorithms used in the past, our artifact mitigation specifically removes artifacts caused by noise. It does not change frequency response characteristics, such as narrow-band peaks and notches in absorbance at different frequencies that can be important for diagnosis. Also, by reducing intermeasurement variability, the artifact mitigation can improve the test-retest reliability of these measurements.
Collapse
|
6
|
Sapp C, Stirn J, O'Hollearn T, Walker EA. Expanding the Role of Educational Audiologists After a Failed Newborn Hearing Screening: A Quality Improvement Study. Am J Audiol 2021; 30:631-641. [PMID: 34269595 PMCID: PMC8642079 DOI: 10.1044/2021_aja-21-00003] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 02/23/2021] [Accepted: 04/11/2021] [Indexed: 12/16/2022] Open
Abstract
Purpose Lack of timely and proximal access to diagnostic hearing evaluation using auditory brainstem response (ABR) testing hampers the effectiveness of Early Hearing Detection and Intervention (EHDI) programs in the United States. This study measured the impact of a state-based quality-improvement (QI) project that provided diagnostic ABR equipment and training to educational audiologists distributed throughout Iowa in regional special education centers. Method We used de-identified administrative data generated by the state EHDI program to analyze markers of access to early hearing health care for infants in a preproject condition ("Baseline") compared to the implementation of diagnostic ABRs at the regional special education centers ("QI Project"). Results Our findings revealed that the QI Project was associated with improvements in timeliness of first hearing evaluation, distance traveled for first hearing evaluation, and likelihood of receiving on-guideline audiology care during the first hearing evaluation. Conclusions Following the onset of the QI Project, infants and their families had greater access to initial hearing evaluation after failed newborn hearing screening. This improvement could have cascading effects on timeliness of later intervention among those with confirmed permanent childhood hearing loss.
Collapse
Affiliation(s)
- Caitlin Sapp
- University of North Carolina Medical Center, Chapel Hill
| | | | | | | |
Collapse
|
7
|
Improving the Differential Diagnosis of Otitis Media With Effusion Using Wideband Acoustic Immittance. Ear Hear 2021; 42:1183-1194. [PMID: 33928915 DOI: 10.1097/aud.0000000000001037] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The objective of this work is to determine whether there is a systematic effect of middle ear effusion volume on wideband acoustic immittance in children with surgically confirmed otitis media with effusion. DESIGN Wideband acoustic immittance was measured in 49 ears from children (9 months to 11 years) who had a diagnosis of otitis media with effusion and compared to 14 ears from children (10 months to 10 years) without a recent history of otitis media. For children with otitis media with effusion, wideband acoustic immittance testing took place in the child's preoperative waiting room before surgical placement of tympanostomy tubes. Testing was completed in a pressurized condition (wideband tympanometry) for all ears as well as in an ambient condition in a subset of ears. Intraoperative findings regarding effusion volume were reported by the surgeons immediately before tube placement and confirmed following myringotomy. This classified the volume of effusion as compared to middle ear volume categorically as either full, partial, or clear of effusion. The type of wideband acoustic immittance explored in this work was absorbance. Absorbance responses were grouped based on effusion volume into one of four groups: full effusions, partial effusions, ears clear of effusion at the time of surgery, and normal control ears. Standard tympanometry was also completed on all ears. RESULTS Absorbance is systematically reduced as the volume of the middle ear effusion increases. This reduction is present at most frequencies but is greatest in the frequency range from 1 to 5 kHz. A multivariate logistic regression approach was utilized to classify ears based on effusion volume. The regression approach classified ears as effusion present (full and partial ears) or absent (clear ears and normal control ears) with 100% accuracy, ears with effusion present as either partial or full with 100% accuracy, and ears without effusion as either normal control ears or ears clear of effusion with 75% accuracy. Regression performance was also explored when the dataset was split into a training set (70% of the data) and a validation test set (30% of the data) to simulate how this approach would perform on unseen data in a clinical setting. Accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve are reported. Overall, this approach demonstrates high sensitivity and specificity for classifying ears as effusion being present or absent and as present effusions being full or partial with areas under the curve ranging from 1 to 0.944. Despite the lack of effusion present in both clear ears and normal control ears, this approach was able to distinguish between these ears, but with a more moderate sensitivity and specificity. No systematic effect of effusion volume was found on standard tympanometry. CONCLUSIONS Wideband acoustic immittance, and more specifically, absorbance, is a strong and sensitive indicator of the volume of a middle ear effusion in children with otitis media with effusion.
Collapse
|
8
|
Refining Measurements of Power Absorbance in Newborns: Probe Fit and Intrasubject Variability. Ear Hear 2020; 42:531-546. [PMID: 33074952 DOI: 10.1097/aud.0000000000000954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Because unresolved debris in the ear canal or middle ear of newborns may produce high false positive rates on hearing screening tests, it has been suggested that an outer/middle ear measure can be included at the time of hearing screening. A potential measure is power absorbance (absorbance), which indicates the proportion of power in a broadband acoustic stimulus that is absorbed through the outer/middle ear. Although absorbance is sensitive to outer/middle dysfunction at birth, there is large variability that limits its accuracy. Acoustic leaks caused by poor probe fitting further exacerbate this issue. The objectives of this work were to: (1) develop criteria to indicate whether a change in absorbance occurs in association with probe fit; (2) describe the variability in absorbance due to poor fitting; and (3) evaluate test-retest variability with probe reinsertions, excluding poor fits. DESIGN An observational cross-sectional design was used to evaluate changes in absorbance due to probe fit and probe reinsertion. Repeated measurements were recorded in 50 newborns (98 ears) who passed TEOAE screenings and were <48 hours of age. One absorbance measurement was chosen as the baseline that served as a best-fit reference in each ear. Changes in absorbance, called absorbance probe-fit Δ, were calculated relative to the baseline in each ear. Correlations were assessed between the absorbance probe-fit Δ and low-frequency absorbance, impedance magnitude, impedance phase, and equivalent volume, to determine which measures predicted poor fits. Criteria were derived from the strongest of these correlations and their performance was analyzed. Next, measurements with poor/leaky fits were identified, and the changes in absorbance that they introduced were analyzed. Excluding the poor fits, test-retest differences in absorbance, called reinsertion Δ, were determined. Variability was assessed using the SDs associated with absorbance, absorbance probe-fit Δ, and reinsertion Δ. RESULTS Based on the analysis of 12 moderate-strong correlations, the following criteria were adopted to identify measurements with poor fits: (1) impedance phase-based criterion (500 to 1000 Hz) > -0.11 cycles and (2) absorbance-based criterion (250 to 1000 Hz) > 0.58. Poor-fit measurements introduced statistically significant increases in absorbance up to 0.1 for 1000 to 6000 Hz, and up to 0.4 for frequencies <1000 Hz. Reinsertion Δ were ≤0.02, and were significant for 500 to 5000 Hz. The SDs of absorbance probe-fit Δ were greatest and similar to overall absorbance SD in the low frequencies. Separately, the SDs of reinsertion Δ were also greatest and similar to low-frequency absorbance SD. CONCLUSIONS Poor probe fits introduced the greatest inflation in absorbance for frequencies < 500 Hz, and a smaller but significant inflation for higher frequencies, consistent with controlled experiments on acoustic leaks in adults. Importantly, inflation of absorbance in diagnostically sensitive 1000 to 2000 Hz may impact its clinical performance. Test-retest with probe reinsertion contributed significantly to absorbance variability, especially in the low frequencies, consistent with reports in adults, even though changes were smaller than those associated with poor probe fit. The results indicate that variability in absorbance was reduced by minimizing acoustic leaks. Pending further validation, the probe-fit criteria developed in this work can be recommended to ensure proper probe fit.
Collapse
|
9
|
Li A, Gao G, Wang N, Fu T, Zhu F, Zhang X, Liu J. The characteristic of otoacoustic emissions in full-term neonates according to ABO blood groups. Braz J Otorhinolaryngol 2019; 86:774-780. [PMID: 31875839 PMCID: PMC9422354 DOI: 10.1016/j.bjorl.2019.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 09/29/2019] [Accepted: 10/27/2019] [Indexed: 11/30/2022] Open
Abstract
Introduction Previous research has suggested that individuals with different blood groups show varied incidences of noise-induced hearing loss. The reduced otoacoustic emissions amplitudes indicate the higher possibilities of outer hair cell damage for noise exposure. Objective The objective is to analyze the characteristics of otoacoustic emissions, including the occurrence of spontaneous otoacoustic emission and the amplitudes of distortion product otoacoustic emission at certain frequencies in full term neonates with different ABO blood groups. Methods A total of 80 selected full-term female neonates who passed the initial newborn hearing screen were enrolled into the study, with equal number of participants in four ABO blood groups (Blood Group A, Blood Group B, Blood Group AB, Blood Group O). Measurements of spontaneous otoacoustic emission and distortion product otoacoustic emission were performed in both ears for all participants. Results (1) The blood group O participants showed significantly fewer spontaneous otoacoustic emission occurrences than the other three blood groups (A = 70%, B = 80%, AB = 67%, O = 25%, p < 0.05). (2) The blood group O participants showed lower DPOAE amplitudes at 1257 Hz (M = 4.55 dB, SD = 8.36), 1587 Hz (M = 11.60 dB, SD = 6.57), 3174 Hz (M = 7.25 dB, SD = 5.99), 5042 Hz (M = 13.60, SD = 6.70) than participants with the other three blood groups in left ears (p < 0.05). In right ears, the blood group O participants showed reduced amplitudes at 1257 Hz (M = 6.55 dB, SD = 8.36), 1587 Hz (M = 13.60 dB, SD = 6.57), 3174 Hz (M = 7.65 dB, SD = 6.43), 5042 Hz (M = 13.65 dB, SD = 6.50) than participants from non-O blood groups (p < 0.05). Conclusion Female individuals with blood group O have lower otoacoustic emissions values than individuals with the other three blood groups. We need to further investigate the possible relationships between ABO blood group and cochlear function, including the potential influences of noise damage on cochlear outer hair cells.
Collapse
Affiliation(s)
- Aifeng Li
- The Affiliated Hospital of Qingdao University, Department of Otolaryngology Head and Neck Surgery, Qingdao, China.
| | - Guoqiang Gao
- The Affiliated Hospital of Qingdao University, Department of Obstetrics, China
| | - Ningyu Wang
- Capital Medical University, Beijing Chaoyang Hospital, Department of Otorhinolaryngology Head and Neck Surgery, China
| | - Tao Fu
- The Affiliated Hospital of Qingdao University, Department of Otolaryngology Head and Neck Surgery, Qingdao, China
| | - Fugao Zhu
- The Affiliated Hospital of Qingdao University, Department of Otolaryngology Head and Neck Surgery, Qingdao, China
| | - Xiaoheng Zhang
- The Affiliated Hospital of Qingdao University, Department of Otolaryngology Head and Neck Surgery, Qingdao, China
| | - Jie Liu
- The Affiliated Hospital of Qingdao University, Department of Otolaryngology Head and Neck Surgery, Qingdao, China
| |
Collapse
|
10
|
Myers J, Kei J, Aithal S, Aithal V, Driscoll C, Khan A, Manuel A, Joseph A, Malicka AN. Longitudinal Development of Wideband Absorbance and Admittance Through Infancy. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2019; 62:2535-2552. [PMID: 31265355 DOI: 10.1044/2019_jslhr-h-18-0480] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Purpose The aim of this article was to study the normal longitudinal development of wideband absorbance and admittance measures through infancy. Method Two hundred one infants who passed the newborn hearing screen (automated auditory brainstem response) were tested at birth and then followed up at approximately 6, 12, and 18 months of age. Most infants were of either White (86%) or Asian (11%) descent. At each test session, infants passed tympanometry and distortion product otoacoustic emission tests. High-frequency (1000-Hz) tympanometry was used at birth and 6 months of age, and low-frequency (226-Hz) tympanometry was used at 12 and 18 months of age. Wideband pressure reflectance was also measured at each session and analyzed in terms of absorbance, admittance at the probe tip, and admittance normalized for differences in ear canal area. Multilevel hierarchical models were fitted to the absorbance and admittance data to investigate for effects of age, ear side, gender, ethnicity, and frequency. Results There were considerable age effects on wideband absorbance and admittance measurements over the first 18 months of life. The most dramatic changes occurred between birth and 6 months of age, and there were significant differences between all age groups in the 3000- to 4000-Hz region. There were significant ethnicity effects that were substantial for certain combinations of ethnicity, age, and frequency (e.g., absorbance at 6000 Hz at 12 months of age). Conclusion There are large developmental effects on wideband absorbance and admittance measures through infancy. For absorbance, we recommend separate reference data be used at birth, 6 months of age, and 12-18 months of age. For admittance (both normalized and at the probe tip), we advise using separate normative regions for each age group (neonates and 6, 12, and 18 months).
Collapse
Affiliation(s)
- Joshua Myers
- Department of Audiology, Townsville Hospital and Health Service, Queensland, Australia
- School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia
| | - Joseph Kei
- School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia
| | - Sreedevi Aithal
- Department of Audiology, Townsville Hospital and Health Service, Queensland, Australia
- School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia
| | - Venkatesh Aithal
- Department of Audiology, Townsville Hospital and Health Service, Queensland, Australia
- School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia
| | - Carlie Driscoll
- School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia
| | - Asaduzzaman Khan
- School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia
| | - Alehandrea Manuel
- Department of Audiology, Townsville Hospital and Health Service, Queensland, Australia
| | - Anjali Joseph
- School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia
| | - Alicja N Malicka
- School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia
- School of Allied Health, La Trobe University, Melbourne, Victoria, Australia
| |
Collapse
|
11
|
A Longitudinal Analysis of Pressurized Wideband Absorbance Measures in Healthy Young Infants. Ear Hear 2019; 40:1233-1241. [PMID: 30807541 DOI: 10.1097/aud.0000000000000707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Wideband absorbance (WBA) is an emerging technology to evaluate the conductive pathway (outer and middle ear) in young infants. While a wealth of research has been devoted to measuring WBA at ambient pressure, few studies have investigated the use of pressurized WBA with this population. The purpose of this study was to investigate the effect of age on WBA measured under pressurized conditions in healthy infants from 0 to 6 months of age. DESIGN Forty-four full-term healthy neonates (17 males and 27 females) participated in a longitudinal study. The neonates were assessed at 1-month intervals from 0 to 6 months of age using high-frequency tympanometry, acoustic stapedial reflex, distortion product otoacoustic emissions, and pressurized WBA. The values of WBA at tympanometric peak pressure (TPP) and 0 daPa across the frequencies from 0.25 to 8 kHz were analyzed as a function of age. RESULTS A linear mixed model analysis, applied to the data, revealed significantly different WBA patterns among the age groups. In general, WBA measured at TPP and 0 daPa decreased at low frequencies (<0.4 kHz) and increased at high frequencies (2 to 5and 8 kHz) with age. Specifically, WBA measured at TPP and 0 daPa in 3- to 6-month-olds was significantly different from that of 0- to 2-month-olds at low (0.25 to 0.31 kHz) and high (2 to 5 and 8 kHz) frequencies. However, there were no significant differences between WBA measured at TPP and 0 daPa for infants from 3 to 6 months of age. CONCLUSIONS The present study provided clear evidence of maturation of the outer and middle ear system in healthy infants from birth to 6 months. Therefore, age-specific normative data of pressurized WBA are warranted.
Collapse
|
12
|
Aithal S, Kei J, Aithal V, Manuel A, Myers J, Driscoll C, Khan A. Normative Study of Wideband Acoustic Immittance Measures in Newborn Infants. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2017; 60:1417-1426. [PMID: 28395306 DOI: 10.1044/2016_jslhr-h-16-0237] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2016] [Accepted: 10/20/2016] [Indexed: 06/07/2023]
Abstract
OBJECTIVE The purpose of this study was to describe normative aspects of wideband acoustic immittance (WAI) measures obtained from healthy White neonates. METHOD In this cross-sectional study, wideband absorbance (WBA), admittance magnitude, and admittance phase were measured under ambient pressure condition in 326 ears from 203 neonates (M age = 45.9 hr) who passed a battery of tests, including automated auditory brainstem response, high-frequency tympanometry, and distortion product otoacoustic emissions. RESULTS Normative WBA data were in agreement with most previous studies. Normative data for both WBA and admittance magnitude revealed double-peaked patterns with the 1st peak at 1.25-2 kHz and the 2nd peak at 5-8 kHz, while normative admittance phase data showed 2 peaks at 0.8 and 4 kHz. There were no significant differences between ears or gender for the 3 WAI measures. Standard deviations for all 3 measures were highest at frequencies above 4 kHz. CONCLUSIONS The 3 WAI measures between 1 kHz and 4 kHz may provide the most stable response of the outer and middle ear. WAI measures at frequencies above 4 kHz were more variable. The normative data established in the present study may serve as a reference for evaluating outer and middle ear function in neonates.
Collapse
Affiliation(s)
- Sreedevi Aithal
- Department of Audiology, The Townsville Hospital, Queensland, Australia
| | - Joseph Kei
- Hearing Research Unit for Children, School of Health and Rehabilitation Sciences, University of Queensland, Brisbane, Australia
| | - Venkatesh Aithal
- Department of Audiology, The Townsville Hospital, Queensland, AustraliaHearing Research Unit for Children, School of Health and Rehabilitation Sciences, University of Queensland, Brisbane, Australia
| | - Alehandrea Manuel
- Department of Audiology, The Townsville Hospital, Queensland, AustraliaHearing Research Unit for Children, School of Health and Rehabilitation Sciences, University of Queensland, Brisbane, Australia
| | - Joshua Myers
- Department of Audiology, The Townsville Hospital, Queensland, AustraliaHearing Research Unit for Children, School of Health and Rehabilitation Sciences, University of Queensland, Brisbane, Australia
| | - Carlie Driscoll
- Hearing Research Unit for Children, School of Health and Rehabilitation Sciences, University of Queensland, Brisbane, Australia
| | - Asaduzzaman Khan
- Hearing Research Unit for Children, School of Health and Rehabilitation Sciences, University of Queensland, Brisbane, Australia
| |
Collapse
|