1
|
Anderson SR, Burg E, Suveg L, Litovsky RY. Review of Binaural Processing With Asymmetrical Hearing Outcomes in Patients With Bilateral Cochlear Implants. Trends Hear 2024; 28:23312165241229880. [PMID: 38545645 PMCID: PMC10976506 DOI: 10.1177/23312165241229880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 01/11/2024] [Accepted: 01/16/2024] [Indexed: 04/01/2024] Open
Abstract
Bilateral cochlear implants (BiCIs) result in several benefits, including improvements in speech understanding in noise and sound source localization. However, the benefit bilateral implants provide among recipients varies considerably across individuals. Here we consider one of the reasons for this variability: difference in hearing function between the two ears, that is, interaural asymmetry. Thus far, investigations of interaural asymmetry have been highly specialized within various research areas. The goal of this review is to integrate these studies in one place, motivating future research in the area of interaural asymmetry. We first consider bottom-up processing, where binaural cues are represented using excitation-inhibition of signals from the left ear and right ear, varying with the location of the sound in space, and represented by the lateral superior olive in the auditory brainstem. We then consider top-down processing via predictive coding, which assumes that perception stems from expectations based on context and prior sensory experience, represented by cascading series of cortical circuits. An internal, perceptual model is maintained and updated in light of incoming sensory input. Together, we hope that this amalgamation of physiological, behavioral, and modeling studies will help bridge gaps in the field of binaural hearing and promote a clearer understanding of the implications of interaural asymmetry for future research on optimal patient interventions.
Collapse
Affiliation(s)
- Sean R. Anderson
- Waisman Center, University of Wisconsin-Madison, Madison, WI, USA
- Department of Physiology and Biophysics, University of Colorado Anschutz Medical School, Aurora, CO, USA
| | - Emily Burg
- Waisman Center, University of Wisconsin-Madison, Madison, WI, USA
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Lukas Suveg
- Waisman Center, University of Wisconsin-Madison, Madison, WI, USA
| | - Ruth Y. Litovsky
- Waisman Center, University of Wisconsin-Madison, Madison, WI, USA
- Department of Communication Sciences and Disorders, University of Wisconsin-Madison, Madison, WI, USA
- Department of Surgery, Division of Otolaryngology, University of Wisconsin-Madison, Madison, WI, USA
| |
Collapse
|
2
|
Cychosz M, Xu K, Fu QJ. Effects of spectral smearing on speech understanding and masking release in simulated bilateral cochlear implants. PLoS One 2023; 18:e0287728. [PMID: 37917727 PMCID: PMC10621938 DOI: 10.1371/journal.pone.0287728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 06/11/2023] [Indexed: 11/04/2023] Open
Abstract
Differences in spectro-temporal degradation may explain some variability in cochlear implant users' speech outcomes. The present study employs vocoder simulations on listeners with typical hearing to evaluate how differences in degree of channel interaction across ears affects spatial speech recognition. Speech recognition thresholds and spatial release from masking were measured in 16 normal-hearing subjects listening to simulated bilateral cochlear implants. 16-channel sine-vocoded speech simulated limited, broad, or mixed channel interaction, in dichotic and diotic target-masker conditions, across ears. Thresholds were highest with broad channel interaction in both ears but improved when interaction decreased in one ear and again in both ears. Masking release was apparent across conditions. Results from this simulation study on listeners with typical hearing show that channel interaction may impact speech recognition more than masking release, and may have implications for the effects of channel interaction on cochlear implant users' speech recognition outcomes.
Collapse
Affiliation(s)
- Margaret Cychosz
- Department of Linguistics, University of California, Los Angeles, Los Angeles, CA, United States of America
| | - Kevin Xu
- Department of Head and Neck Surgery, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, United States of America
| | - Qian-Jie Fu
- Department of Head and Neck Surgery, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, United States of America
| |
Collapse
|
3
|
Yoshida T, Hara D, Kobayashi M, Sugimoto S, Fukunaga Y, Sone M. Evaluation of the Listening Environment of Bilateral Cochlear Implant Users through Data Logging: A Comparison of Bilateral Simultaneous and Sequential Implantation. Otol Neurotol 2023; 44:e560-e565. [PMID: 37525397 DOI: 10.1097/mao.0000000000003955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/02/2023]
Abstract
OBJECTIVE To evaluate the listening conditions of bilateral cochlear implant (CI) users in their daily living environment. STUDY DESIGN Retrospective study. SETTING University hospital. PATIENTS Thirty-one adult CI users 16 years or older; 18 underwent sequential surgery, and 13 underwent simultaneous surgery. Inclusion criteria included the availability of CI data logging features and a minimum duration of binaural use of 6 months. INTERVENTION Retrospective analysis of data obtained from the automatic scene classifier data logging system. MAIN OUTCOME MEASURE Comparison of data logging and maximum speech discrimination scores of the two surgery groups (sequential vs. simultaneous) to investigate the potential influence of these factors on the listening conditions of CI users. RESULTS The maximum speech discrimination score of the second CI in the sequential group was significantly worse than that of any other CI in the sequential and simultaneous CI groups. Additionally, the longer the interval between surgeries, the more significant the difference in "time on air" between the first and the second CIs. The second CI in sequential CI surgery had a shorter "time on air" than the first or the bilateral simultaneous CIs; the second CI was also used more frequently in noisy and speech with background noise environments. CONCLUSIONS A second CI may be more frequently used in challenging listening environments because of its binaural auditory effect, despite its lower speech discrimination performance. The timing of sequential implantation and the potential impact of binaural hearing should be considered when developing rehabilitation strategies for individuals with bilateral CIs.
Collapse
Affiliation(s)
- Tadao Yoshida
- Department of Otorhinolaryngology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Daisuke Hara
- Department of Rehabilitation, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Masumi Kobayashi
- Department of Otorhinolaryngology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Satofumi Sugimoto
- Department of Otorhinolaryngology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Yukari Fukunaga
- Department of Rehabilitation, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Michihiko Sone
- Department of Otorhinolaryngology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| |
Collapse
|
4
|
Cleary M, DeRoy Milvae K, Nguyen N, Bernstein JGW, Goupell MJ. Effect of experimentally introduced interaural frequency mismatch on sentence recognition in bilateral cochlear-implant listeners. JASA EXPRESS LETTERS 2023; 3:044401. [PMID: 37096891 PMCID: PMC10080388 DOI: 10.1121/10.0017705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 03/13/2023] [Indexed: 05/03/2023]
Abstract
Bilateral cochlear-implant users experience interaural frequency mismatch because of asymmetries in array insertion and frequency-to-electrode assignment. To explore the acute perceptual consequences of such mismatch, sentence recognition in quiet was measured in nine bilateral cochlear-implant listeners as frequency allocations in the poorer ear were shifted by ±1.5, ±3, and ±4.5 mm using experimental programs. Shifts in frequency allocation >3 mm reduced bilateral sentence scores below those for the better ear alone, suggesting that the poorer ear interfered with better-ear perception. This was not a result of fewer active channels; deactivating electrodes without frequency shifting had minimal effect.
Collapse
Affiliation(s)
- Miranda Cleary
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Kristina DeRoy Milvae
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Nicole Nguyen
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Joshua G W Bernstein
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889, , , , ,
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| |
Collapse
|
5
|
Cleary M, DeRoy Milvae K, Nguyen N, Bernstein JGW, Goupell MJ. Effect of experimentally introduced interaural frequency mismatch on sentence recognition in bilateral cochlear-implant listeners. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.01.06.23284274. [PMID: 36711489 PMCID: PMC9882401 DOI: 10.1101/2023.01.06.23284274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Bilateral cochlear-implant users experience interaural frequency mismatch because of asymmetries in array insertion and frequency-to-electrode assignment. To explore the acute perceptual consequences of such mismatch, sentence recognition in quiet was measured in nine bilateral cochlear-implant listeners as frequency allocations in the poorer ear were shifted by ±1.5, ±3 and ±4.5 mm using experimental programs. Shifts in frequency allocation >3 mm were found to reduce bilateral sentence scores below those for the better ear alone, suggesting that the poorer ear interfered with better-ear perception. This was not a result of fewer active channels; deactivating electrodes without frequency shifting had minimal effect.
Collapse
Affiliation(s)
- Miranda Cleary
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| | - Kristina DeRoy Milvae
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA,Department of Communicative Disorders and Sciences, University at Buffalo, Buffalo, NY, USA
| | - Nicole Nguyen
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| | - Joshua G. W. Bernstein
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, MD, USA
| | - Matthew J. Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| |
Collapse
|
6
|
Anderson SR, Gallun FJ, Litovsky RY. Interaural asymmetry of dynamic range: Abnormal fusion, bilateral interference, and shifts in attention. Front Neurosci 2023; 16:1018190. [PMID: 36699517 PMCID: PMC9869277 DOI: 10.3389/fnins.2022.1018190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Accepted: 12/19/2022] [Indexed: 01/12/2023] Open
Abstract
Speech information in the better ear interferes with the poorer ear in patients with bilateral cochlear implants (BiCIs) who have large asymmetries in speech intelligibility between ears. The goal of the present study was to assess how each ear impacts, and whether one dominates, speech perception using simulated CI processing in older and younger normal-hearing (ONH and YNH) listeners. Dynamic range (DR) was manipulated symmetrically or asymmetrically across spectral bands in a vocoder. We hypothesized that if abnormal integration of speech information occurs with asymmetrical speech understanding, listeners would demonstrate an atypical preference in accuracy when reporting speech presented to the better ear and fusion of speech between the ears (i.e., an increased number of one-word responses when two words were presented). Results from three speech conditions showed that: (1) When the same word was presented to both ears, speech identification accuracy decreased if one or both ears decreased in DR, but listeners usually reported hearing one word. (2) When two words with different vowels were presented to both ears, speech identification accuracy and percentage of two-word responses decreased consistently as DR decreased in one or both ears. (3) When two rhyming words (e.g., bed and led) previously shown to phonologically fuse between ears (e.g., bled) were presented, listeners instead demonstrated interference as DR decreased. The word responded in (2) and (3) came from the right (symmetric) or better (asymmetric) ear, especially in (3) and for ONH listeners in (2). These results suggest that the ear with poorer dynamic range is downweighted by the auditory system, resulting in abnormal fusion and interference, especially for older listeners.
Collapse
Affiliation(s)
- Sean R. Anderson
- Waisman Center, University of Wisconsin-Madison, Madison, WI, United States
| | - Frederick J. Gallun
- Department of Otolaryngology-Head and Neck Surgery, Oregon Health and Science University, Portland, OR, United States
| | - Ruth Y. Litovsky
- Waisman Center, University of Wisconsin-Madison, Madison, WI, United States
- Department of Communication Sciences and Disorders, University of Wisconsin-Madison, Madison, WI, United States
- Department of Surgery, Division of Otolaryngology, University of Wisconsin-Madison, Madison, WI, United States
| |
Collapse
|
7
|
Cochlear Implant Facilitates the Use of Talker Sex and Spatial Cues to Segregate Competing Speech in Unilaterally Deaf Listeners. Ear Hear 2023; 44:77-91. [PMID: 35733275 DOI: 10.1097/aud.0000000000001254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVES Talker sex and spatial cues can facilitate segregation of competing speech. However, the spectrotemporal degradation associated with cochlear implants (CIs) can limit the benefit of talker sex and spatial cues. Acoustic hearing in the nonimplanted ear can improve access to talker sex cues in CI users. However, it's unclear whether the CI can improve segregation of competing speech when maskers are symmetrically placed around the target (i.e., when spatial cues are available), compared with acoustic hearing alone. The aim of this study was to investigate whether a CI can improve segregation of competing speech by individuals with unilateral hearing loss. DESIGN Speech recognition thresholds (SRTs) for competing speech were measured in 16 normal-hearing (NH) adults and 16 unilaterally deaf CI users. All participants were native speakers of Mandarin Chinese. CI users were divided into two groups according to thresholds in the nonimplanted ear: (1) single-sided deaf (SSD); pure-tone thresholds <25 dB HL at all audiometric frequencies, and (2) Asymmetric hearing loss (AHL; one or more thresholds > 25 dB HL). SRTs were measured for target sentences produced by a male talker in the presence of two masker talkers (different male or female talkers). The target sentence was always presented via loudspeaker directly in front of the listener (0°), and the maskers were either colocated with the target (0°) or spatially separated from the target at ±90°. Three segregation cue conditions were tested to measure masking release (MR) relative to the baseline condition: (1) Talker sex, (2) Spatial, and (3) Talker sex + Spatial. For CI users, SRTs were measured with the CI on or off. RESULTS Binaural MR was significantly better for the NH group than for the AHL or SSD groups ( P < 0.001 in all cases). For the NH group, mean MR was largest with the Talker sex + spatial cues (18.8 dB) and smallest for the Talker sex cues (10.7 dB). In contrast, mean MR for the SSD group was largest with the Talker sex + spatial cues (14.7 dB), and smallest with the Spatial cues (4.8 dB). For the AHL group, mean MR was largest with the Talker sex + spatial cues (7.8 dB) and smallest with the Talker sex (4.8 dB) and the Spatial cues (4.8 dB). MR was significantly better with the CI on than off for both the AHL ( P = 0.014) and SSD groups ( P < 0.001). Across all unilaterally deaf CI users, monaural (acoustic ear alone) and binaural MR were significantly correlated with unaided pure-tone average thresholds in the nonimplanted ear for the Talker sex and Talker sex + spatial conditions ( P < 0.001 in both cases) but not for the Spatial condition. CONCLUSION Although the CI benefitted unilaterally deaf listeners' segregation of competing speech, MR was much poorer than that observed in NH listeners. Different from previous findings with steady noise maskers, the CI benefit for segregation of competing speech from a different talker sex was greater in the SSD group than in the AHL group.
Collapse
|
8
|
Burg EA, Thakkar TD, Litovsky RY. Interaural speech asymmetry predicts bilateral speech intelligibility but not listening effort in adults with bilateral cochlear implants. Front Neurosci 2022; 16:1038856. [PMID: 36570844 PMCID: PMC9768552 DOI: 10.3389/fnins.2022.1038856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Accepted: 11/21/2022] [Indexed: 12/12/2022] Open
Abstract
Introduction Bilateral cochlear implants (BiCIs) can facilitate improved speech intelligibility in noise and sound localization abilities compared to a unilateral implant in individuals with bilateral severe to profound hearing loss. Still, many individuals with BiCIs do not benefit from binaural hearing to the same extent that normal hearing (NH) listeners do. For example, binaural redundancy, a speech intelligibility benefit derived from having access to duplicate copies of a signal, is highly variable among BiCI users. Additionally, patients with hearing loss commonly report elevated listening effort compared to NH listeners. There is some evidence to suggest that BiCIs may reduce listening effort compared to a unilateral CI, but the limited existing literature has not shown this consistently. Critically, no studies to date have investigated this question using pupillometry to quantify listening effort, where large pupil sizes indicate high effort and small pupil sizes indicate low effort. Thus, the present study aimed to build on existing literature by investigating the potential benefits of BiCIs for both speech intelligibility and listening effort. Methods Twelve BiCI adults were tested in three listening conditions: Better Ear, Poorer Ear, and Bilateral. Stimuli were IEEE sentences presented from a loudspeaker at 0° azimuth in quiet. Participants were asked to repeat back the sentences, and responses were scored by an experimenter while changes in pupil dilation were measured. Results On average, participants demonstrated similar speech intelligibility in the Better Ear and Bilateral conditions, and significantly worse speech intelligibility in the Poorer Ear condition. Despite similar speech intelligibility in the Better Ear and Bilateral conditions, pupil dilation was significantly larger in the Bilateral condition. Discussion These results suggest that the BiCI users tested in this study did not demonstrate binaural redundancy in quiet. The large interaural speech asymmetries demonstrated by participants may have precluded them from obtaining binaural redundancy, as shown by the inverse relationship between the two variables. Further, participants did not obtain a release from effort when listening with two ears versus their better ear only. Instead, results indicate that bilateral listening elicited increased effort compared to better ear listening, which may be due to poor integration of asymmetric inputs.
Collapse
Affiliation(s)
- Emily A. Burg
- Waisman Center, University of Wisconsin-Madison, Madison, WI, United States,Department of Communication Sciences and Disorders, University of Wisconsin-Madison, Madison, WI, United States,*Correspondence: Emily A. Burg,
| | - Tanvi D. Thakkar
- Department of Psychology, University of Wisconsin-La Crosse, La Crosse, WI, United States
| | - Ruth Y. Litovsky
- Waisman Center, University of Wisconsin-Madison, Madison, WI, United States,Department of Communication Sciences and Disorders, University of Wisconsin-Madison, Madison, WI, United States,Division of Otolaryngology, Department of Surgery, University of Wisconsin-Madison, Madison, WI, United States
| |
Collapse
|
9
|
A Web-Based Automated Image Processing Research Platform for Cochlear Implantation-Related Studies. J Clin Med 2022; 11:jcm11226640. [PMID: 36431117 PMCID: PMC9699139 DOI: 10.3390/jcm11226640] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 10/27/2022] [Accepted: 10/28/2022] [Indexed: 11/11/2022] Open
Abstract
The robust delineation of the cochlea and its inner structures combined with the detection of the electrode of a cochlear implant within these structures is essential for envisaging a safer, more individualized, routine image-guided cochlear implant therapy. We present Nautilus-a web-based research platform for automated pre- and post-implantation cochlear analysis. Nautilus delineates cochlear structures from pre-operative clinical CT images by combining deep learning and Bayesian inference approaches. It enables the extraction of electrode locations from a post-operative CT image using convolutional neural networks and geometrical inference. By fusing pre- and post-operative images, Nautilus is able to provide a set of personalized pre- and post-operative metrics that can serve the exploration of clinically relevant questions in cochlear implantation therapy. In addition, Nautilus embeds a self-assessment module providing a confidence rating on the outputs of its pipeline. We present a detailed accuracy and robustness analyses of the tool on a carefully designed dataset. The results of these analyses provide legitimate grounds for envisaging the implementation of image-guided cochlear implant practices into routine clinical workflows.
Collapse
|
10
|
Chou KF, Boyd AD, Best V, Colburn HS, Sen K. A biologically oriented algorithm for spatial sound segregation. Front Neurosci 2022; 16:1004071. [PMID: 36312015 PMCID: PMC9614053 DOI: 10.3389/fnins.2022.1004071] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Accepted: 09/28/2022] [Indexed: 11/13/2022] Open
Abstract
Listening in an acoustically cluttered scene remains a difficult task for both machines and hearing-impaired listeners. Normal-hearing listeners accomplish this task with relative ease by segregating the scene into its constituent sound sources, then selecting and attending to a target source. An assistive listening device that mimics the biological mechanisms underlying this behavior may provide an effective solution for those with difficulty listening in acoustically cluttered environments (e.g., a cocktail party). Here, we present a binaural sound segregation algorithm based on a hierarchical network model of the auditory system. In the algorithm, binaural sound inputs first drive populations of neurons tuned to specific spatial locations and frequencies. The spiking response of neurons in the output layer are then reconstructed into audible waveforms via a novel reconstruction method. We evaluate the performance of the algorithm with a speech-on-speech intelligibility task in normal-hearing listeners. This two-microphone-input algorithm is shown to provide listeners with perceptual benefit similar to that of a 16-microphone acoustic beamformer. These results demonstrate the promise of this biologically inspired algorithm for enhancing selective listening in challenging multi-talker scenes.
Collapse
Affiliation(s)
- Kenny F. Chou
- Department of Biomedical Engineering, Boston University, Boston, MA, United States
| | - Alexander D. Boyd
- Department of Biomedical Engineering, Boston University, Boston, MA, United States
| | - Virginia Best
- Department of Speech, Language and Hearing Sciences, Boston University, Boston, MA, United States
| | - H. Steven Colburn
- Department of Biomedical Engineering, Boston University, Boston, MA, United States
| | - Kamal Sen
- Department of Biomedical Engineering, Boston University, Boston, MA, United States
- *Correspondence: Kamal Sen,
| |
Collapse
|
11
|
Yoon YS, Drew C. Effects of the intensified frequency and time ranges on consonant enhancement in bilateral cochlear implant and hearing aid users. Front Psychol 2022; 13:918914. [PMID: 36051201 PMCID: PMC9426545 DOI: 10.3389/fpsyg.2022.918914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Accepted: 07/19/2022] [Indexed: 11/13/2022] Open
Abstract
A previous study demonstrated that consonant recognition improved significantly in normal hearing listeners when useful frequency and time ranges were intensified by 6 dB. The goal of this study was to determine whether bilateral cochlear implant (BCI) and bilateral hearing aid (BHA) users experienced similar enhancement on consonant recognition with these intensified spectral and temporal cues in noise. In total, 10 BCI and 10 BHA users participated in a recognition test using 14 consonants. For each consonant, we used the frequency and time ranges that are critical for its recognition (called “target frequency and time range”), identified from normal hearing listeners. Then, a signal processing tool called the articulation-index gram (AI-Gram) was utilized to add a 6 dB gain to target frequency and time ranges. Consonant recognition was monaurally and binaurally measured under two signal processing conditions, unprocessed and intensified target frequency and time ranges at +5 and +10 dB signal-to-noise ratio and in quiet conditions. We focused on three comparisons between the BCI and BHA groups: (1) AI-Gram benefits (i.e., before and after intensifying target ranges by 6 dB), (2) enhancement in binaural benefits (better performance with bilateral devices compared to the better ear alone) via the AI-Gram processing, and (3) reduction in binaural interferences (poorer performance with bilateral devices compared to the better ear alone) via the AI-Gram processing. The results showed that the mean AI-Gram benefit was significantly improved for the BCI (max 5.9%) and BHA (max 5.2%) groups. However, the mean binaural benefit was not improved after AI-Gram processing. Individual data showed wide ranges of the AI-Gram benefit (max −1 to 23%) and binaural benefit (max −7.6 to 13%) for both groups. Individual data also showed a decrease in binaural interference in both groups after AI-Gram processing. These results suggest that the frequency and time ranges, intensified by the AI-Gram processing, contribute to consonant enhancement for monaural and binaural listening and both BCI and BHA technologies. The intensified frequency and time ranges helped to reduce binaural interference but contributed less to the synergistic binaural benefit in consonant recognition for both groups.
Collapse
|
12
|
Gibbs BE, Bernstein JGW, Brungart DS, Goupell MJ. Effects of better-ear glimpsing, binaural unmasking, and spectral resolution on spatial release from masking in cochlear-implant users. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 152:1230. [PMID: 36050186 PMCID: PMC9420049 DOI: 10.1121/10.0013746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Revised: 08/04/2022] [Accepted: 08/06/2022] [Indexed: 06/15/2023]
Abstract
Bilateral cochlear-implant (BICI) listeners obtain less spatial release from masking (SRM; speech-recognition improvement for spatially separated vs co-located conditions) than normal-hearing (NH) listeners, especially for symmetrically placed maskers that produce similar long-term target-to-masker ratios at the two ears. Two experiments examined possible causes of this deficit, including limited better-ear glimpsing (using speech information from the more advantageous ear in each time-frequency unit), limited binaural unmasking (using interaural differences to improve signal-in-noise detection), or limited spectral resolution. Listeners had NH (presented with unprocessed or vocoded stimuli) or BICIs. Experiment 1 compared natural symmetric maskers, idealized monaural better-ear masker (IMBM) stimuli that automatically performed better-ear glimpsing, and hybrid stimuli that added worse-ear information, potentially restoring binaural cues. BICI and NH-vocoded SRM was comparable to NH-unprocessed SRM for idealized stimuli but was 14%-22% lower for symmetric stimuli, suggesting limited better-ear glimpsing ability. Hybrid stimuli improved SRM for NH-unprocessed listeners but degraded SRM for BICI and NH-vocoded listeners, suggesting they experienced across-ear interference instead of binaural unmasking. In experiment 2, increasing the number of vocoder channels did not change NH-vocoded SRM. BICI SRM deficits likely reflect a combination of across-ear interference, limited better-ear glimpsing, and poorer binaural unmasking that stems from cochlear-implant-processing limitations other than reduced spectral resolution.
Collapse
Affiliation(s)
- Bobby E Gibbs
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Joshua G W Bernstein
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889, USA
| | - Douglas S Brungart
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889, USA
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| |
Collapse
|
13
|
Pieper SH, Hamze N, Brill S, Hochmuth S, Exter M, Polak M, Radeloff A, Buschermöhle M, Dietz M. Considerations for Fitting Cochlear Implants Bimodally and to the Single-Sided Deaf. Trends Hear 2022; 26:23312165221108259. [PMID: 35726211 PMCID: PMC9218456 DOI: 10.1177/23312165221108259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
When listening with a cochlear implant through one ear and acoustically through the other, binaural benefits and spatial hearing abilities are generally poorer than in other bilaterally stimulated configurations. With the working hypothesis that binaural neurons require interaurally matched inputs, we review causes for mismatch, their perceptual consequences, and experimental methods for mismatch measurements. The focus is on the three primary interaural dimensions of latency, frequency, and level. Often, the mismatch is not constant, but rather highly stimulus-dependent. We report on mismatch compensation strategies, taking into consideration the specific needs of the respective patient groups. Practical challenges typically faced by audiologists in the proposed fitting procedure are discussed. While improvement in certain areas (e.g., speaker localization) is definitely achievable, a more comprehensive mismatch compensation is a very ambitious endeavor. Even in the hypothetical ideal fitting case, performance is not expected to exceed that of a good bilateral cochlear implant user.
Collapse
Affiliation(s)
- Sabrina H Pieper
- Department of Medical Physics and Acoustic, University of Oldenburg, Oldenburg, Germany.,Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany
| | - Noura Hamze
- MED-EL Medical Electronics GmbH, Innsbruck, Austria
| | - Stefan Brill
- MED-EL Medical Electronics Germany GmbH, Starnberg, Germany
| | - Sabine Hochmuth
- Division of Otorhinolaryngology, University of Oldenburg, Oldenburg, Germany
| | - Mats Exter
- Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany.,Hörzentrum Oldenburg gGmbH, Oldenburg, Germany
| | - Marek Polak
- MED-EL Medical Electronics GmbH, Innsbruck, Austria
| | - Andreas Radeloff
- Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany.,Division of Otorhinolaryngology, University of Oldenburg, Oldenburg, Germany.,Research Center Neurosensory Science, University of Oldenburg, Oldenburg, Germany
| | | | - Mathias Dietz
- Department of Medical Physics and Acoustic, University of Oldenburg, Oldenburg, Germany.,Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany.,Research Center Neurosensory Science, University of Oldenburg, Oldenburg, Germany
| |
Collapse
|
14
|
Bernstein JGW, Jensen KK, Stakhovskaya OA, Noble JH, Hoa M, Kim HJ, Shih R, Kolberg E, Cleary M, Goupell MJ. Interaural Place-of-Stimulation Mismatch Estimates Using CT Scans and Binaural Perception, But Not Pitch, Are Consistent in Cochlear-Implant Users. J Neurosci 2021; 41:10161-10178. [PMID: 34725189 PMCID: PMC8660045 DOI: 10.1523/jneurosci.0359-21.2021] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 08/23/2021] [Accepted: 10/01/2021] [Indexed: 11/21/2022] Open
Abstract
Bilateral cochlear implants (BI-CIs) or a CI for single-sided deafness (SSD-CI; one normally functioning acoustic ear) can partially restore spatial-hearing abilities, including sound localization and speech understanding in noise. For these populations, however, interaural place-of-stimulation mismatch can occur and thus diminish binaural sensitivity that relies on interaurally frequency-matched neurons. This study examined whether plasticity-reorganization of central neural pathways over time-can compensate for peripheral interaural place mismatch. We hypothesized differential plasticity across two systems: none for binaural processing but adaptation for pitch perception toward frequencies delivered by the specific electrodes. Interaural place mismatch was evaluated in 19 BI-CI and 23 SSD-CI human subjects (both sexes) using binaural processing (interaural-time-difference discrimination with simultaneous bilateral stimulation), pitch perception (pitch ranking for single electrodes or acoustic tones with sequential bilateral stimulation), and physical electrode-location estimates from computed-tomography (CT) scans. On average, CT scans revealed relatively little BI-CI interaural place mismatch (26° insertion-angle mismatch) but a relatively large SSD-CI mismatch, particularly at low frequencies (166° for an electrode tuned to 300 Hz, decreasing to 14° at 7000 Hz). For BI-CI subjects, the three metrics were in agreement because there was little mismatch. For SSD-CI subjects, binaural and CT measurements were in agreement, suggesting little binaural-system plasticity induced by mismatch. The pitch measurements disagreed with binaural and CT measurements, suggesting place-pitch plasticity or a procedural bias. These results suggest that reducing interaural place mismatch and potentially improving binaural processing by reprogramming the CI frequency allocation would be better done using CT-scan than pitch information.SIGNIFICANCE STATEMENT Electrode-array placement for cochlear implants (bionic prostheses that partially restore hearing) does not explicitly align neural representations of frequency information. The resulting interaural place-of-stimulation mismatch can diminish spatial-hearing abilities. In this study, adults with two cochlear implants showed reasonable interaural alignment, whereas those with one cochlear implant but normal hearing in the other ear often showed mismatch. In cases of mismatch, binaural sensitivity was best when the same cochlear locations were stimulated in both ears, suggesting that binaural brainstem pathways do not experience plasticity to compensate for mismatch. In contrast, interaurally pitch-matched electrodes deviated from cochlear-location estimates and did not optimize binaural sensitivity. Clinical correction of interaural place mismatch using binaural or computed-tomography (but not pitch) information may improve spatial-hearing benefits.
Collapse
Affiliation(s)
- Joshua G W Bernstein
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889
| | - Kenneth K Jensen
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889
| | - Olga A Stakhovskaya
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742
| | - Jack H Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee 37232
| | - Michael Hoa
- Department of Otolaryngology Head and Neck Surgery, Georgetown University Medical Center, Washington, DC 20057
| | - H Jeffery Kim
- Department of Otolaryngology Head and Neck Surgery, Georgetown University Medical Center, Washington, DC 20057
| | - Robert Shih
- Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland 20889
| | - Elizabeth Kolberg
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742
| | - Miranda Cleary
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742
| |
Collapse
|
15
|
Yoon YS. Effect of the Target and Conflicting Frequency and Time Ranges on Consonant Enhancement in Normal-Hearing Listeners. Front Psychol 2021; 12:733100. [PMID: 34867614 PMCID: PMC8634346 DOI: 10.3389/fpsyg.2021.733100] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Accepted: 10/11/2021] [Indexed: 11/29/2022] Open
Abstract
In this paper, the effects of intensifying useful frequency and time regions (target frequency and time ranges) and the removal of detrimental frequency and time regions (conflicting frequency and time ranges) for consonant enhancement were determined. Thirteen normal-hearing (NH) listeners participated in two experiments. In the first experiment, the target and conflicting frequency and time ranges for each consonant were identified under a quiet, dichotic listening condition by analyzing consonant confusion matrices. The target frequency range was defined as the frequency range that provided the highest performance and was decreased 40% from the peak performance from both high-pass filtering (HPF) and low-pass filtering (LPF) schemes. The conflicting frequency range was defined as the frequency range that yielded the peak errors of the most confused consonants and was 20% less than the peak error from both filtering schemes. The target time range was defined as a consonant segment that provided the highest performance and was decreased 40% from that peak performance when the duration of the consonant was systematically truncated from the onset. The conflicting time ranges were defined on the coincided target time range because, if they temporarily coincide, the conflicting frequency ranges would be the most detrimental factor affecting the target frequency ranges. In the second experiment, consonant recognition was binaurally measured in noise under three signal processing conditions: unprocessed, intensified target ranges by a 6-dB gain (target), and combined intensified target and removed conflicting ranges (target-conflicting). The results showed that consonant recognition improved significantly with the target condition but greatly deteriorated with a target-conflicting condition. The target condition helped transmit voicing and manner cues while the target-conflicting condition limited the transmission of these cues. Confusion analyses showed that the effect of the signal processing on consonant improvement was consonant-specific: the unprocessed condition was the best for /da, pa, ma, sa/; the target condition was the best for /ga, fa, va, za, ʒa/; and the target-conflicting condition was the best for /na, ʃa/. Perception of /ba, ta, ka/ was independent of the signal processing. The results suggest that enhancing the target ranges is an efficient way to improve consonant recognition while the removal of conflicting ranges negatively impacts consonant recognition.
Collapse
Affiliation(s)
- Yang-Soo Yoon
- Laboratory of Translational Auditory Research, Department of Communication Sciences and Disorders, Baylor University, Waco, TX, United States
| |
Collapse
|
16
|
DeRoy Milvae K, Kuchinsky SE, Stakhovskaya OA, Goupell MJ. Dichotic listening performance and effort as a function of spectral resolution and interaural symmetry. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 150:920. [PMID: 34470337 PMCID: PMC8346288 DOI: 10.1121/10.0005653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 06/30/2021] [Accepted: 06/30/2021] [Indexed: 06/13/2023]
Abstract
One potential benefit of bilateral cochlear implants is reduced listening effort in speech-on-speech masking situations. However, the symmetry of the input across ears, possibly related to spectral resolution, could impact binaural benefits. Fifteen young adults with normal hearing performed digit recall with target and interfering digits presented to separate ears and attention directed to the target ear. Recall accuracy and pupil size over time (used as an index of listening effort) were measured for unprocessed, 16-channel vocoded, and 4-channel vocoded digits. Recall accuracy was significantly lower for dichotic (with interfering digits) than for monotic listening. Dichotic recall accuracy was highest when the target was less degraded and the interferer was more degraded. With matched target and interferer spectral resolution, pupil dilation was lower with more degradation. Pupil dilation grew more shallowly over time when the interferer had more degradation. Overall, interferer spectral resolution more strongly affected listening effort than target spectral resolution. These results suggest that interfering speech both lowers performance and increases listening effort, and that the relative spectral resolution of target and interferer affect the listening experience. Ignoring a clearer interferer is more effortful.
Collapse
Affiliation(s)
- Kristina DeRoy Milvae
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Stefanie E Kuchinsky
- Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, Maryland 20889, USA
| | - Olga A Stakhovskaya
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| |
Collapse
|
17
|
Abstract
OBJECTIVES Cochlear implants (CIs) restore some spatial advantages for speech understanding in noise to individuals with single-sided deafness (SSD). In addition to a head-shadow advantage when the CI ear has a better signal-to-noise ratio, a CI can also provide a binaural advantage in certain situations, facilitating the perceptual separation of spatially separated concurrent voices. While some bilateral-CI listeners show a similar binaural advantage, bilateral-CI listeners with relatively large asymmetries in monaural speech understanding can instead experience contralateral speech interference. Based on the interference previously observed for asymmetric bilateral-CI listeners, this study tested the hypothesis that in a multiple-talker situation, the acoustic ear would interfere with rather than improve CI speech understanding for SSD-CI listeners. DESIGN Experiment 1 measured CI-ear speech understanding in the presence of competing speech or noise for 13 SSD-CI listeners. Target speech from the closed-set coordinate response-measure corpus was presented to the CI ear along with one same-gender competing talker or stationary noise at target-to-masker ratios between -8 and 20 dB. The acoustic ear was presented with silence (monaural condition) or with a copy of the competing speech or noise (bilateral condition). Experiment 2 tested a subset of 6 listeners in the reverse configuration for which SSD-CI listeners have previously shown a binaural benefit (target and competing speech presented to the acoustic ear; silence or competing speech presented to the CI ear). Experiment 3 examined the possible influence of a methodological difference between experiments 1 and 2: whether the competing talker spoke keywords that were inside or outside the response set. For each experiment, the data were analyzed using repeated-measures logistic regression. For experiment 1, a correlation analysis compared the difference between bilateral and monaural speech-understanding scores to several listener-specific factors: speech understanding in the CI ear, preimplantation duration of deafness, duration of CI experience, ear of deafness (left/right), acoustic-ear audiometric thresholds, and listener age. RESULTS In experiment 1, presenting a copy of the competing speech to the acoustic ear reduced CI speech-understanding scores for target-to-masker ratios ≥4 dB. This interference effect was limited to competing-speech conditions and was not observed for a noise masker. There was dramatic intersubject variability in the magnitude of the interference (range: 1 to 43 rationalized arcsine units), which was found to be significantly correlated with listener age. The interference effect contrasted sharply with the reverse configuration (experiment 2), whereby presenting a copy of the competing speech to the contralateral CI ear significantly improved performance relative to monaural acoustic-ear performance. Keyword condition (experiment 3) did not influence the observed pattern of interference. CONCLUSIONS Most SSD-CI listeners experienced interference when they attended to the CI ear and competing speech was added to the acoustic ear, although there was a large amount of intersubject variability in the magnitude of the effect, with older listeners particularly susceptible to interference. While further research is needed to investigate these effects under free-field listening conditions, these results suggest that for certain spatial configurations in a multiple-talker situation, contralateral speech interference could reduce the benefit that an SSD-CI otherwise provides.
Collapse
|
18
|
Bakal TA, Milvae KD, Chen C, Goupell MJ. Head Shadow, Summation, and Squelch in Bilateral Cochlear-Implant Users With Linked Automatic Gain Controls. Trends Hear 2021; 25:23312165211018147. [PMID: 34057387 PMCID: PMC8182628 DOI: 10.1177/23312165211018147] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Speech understanding in noise is poorer in bilateral cochlear-implant (BICI) users compared to normal-hearing counterparts. Independent automatic gain controls (AGCs) may contribute to this because adjusting processor gain independently can reduce interaural level differences that BICI listeners rely on for bilateral benefits. Bilaterally linked AGCs may improve bilateral benefits by increasing the magnitude of interaural level differences. The effects of linked AGCs on bilateral benefits (summation, head shadow, and squelch) were measured in nine BICI users. Speech understanding for a target talker at 0° masked by a single talker at 0°, 90°, or −90° azimuth was assessed under headphones with sentences at five target-to-masker ratios. Research processors were used to manipulate AGC type (independent or linked) and test ear (left, right, or both). Sentence recall was measured in quiet to quantify individual interaural asymmetry in functional performance. The results showed that AGC type did not significantly change performance or bilateral benefits. Interaural functional asymmetries, however, interacted with ear such that greater summation and squelch benefit occurred when there was larger functional asymmetry, and interacted with interferer location such that smaller head shadow benefit occurred when there was larger functional asymmetry. The larger benefits for those with larger asymmetry were driven by improvements from adding a better-performing ear, rather than a true binaural-hearing benefit. In summary, linked AGCs did not significantly change bilateral benefits in cases of speech-on-speech masking with a single-talker masker, but there was also no strong detriment across a range of target-to-masker ratios, within a small and diverse BICI listener population.
Collapse
Affiliation(s)
- Taylor A Bakal
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland, United States
| | - Kristina DeRoy Milvae
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland, United States
| | - Chen Chen
- Advanced Bionics LLC, Research and Technology, Valencia, California, United States
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland, United States
| |
Collapse
|
19
|
Binaural Optimization of Cochlear Implants: Discarding Frequency Content Without Sacrificing Head-Shadow Benefit. Ear Hear 2021; 41:576-590. [PMID: 31436754 DOI: 10.1097/aud.0000000000000784] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Single-sided deafness cochlear-implant (SSD-CI) listeners and bilateral cochlear-implant (BI-CI) listeners gain near-normal levels of head-shadow benefit but limited binaural benefits. One possible reason for these limited binaural benefits is that cochlear places of stimulation tend to be mismatched between the ears. SSD-CI and BI-CI patients might benefit from a binaural fitting that reallocates frequencies to reduce interaural place mismatch. However, this approach could reduce monaural speech recognition and head-shadow benefit by excluding low- or high-frequency information from one ear. This study examined how much frequency information can be excluded from a CI signal in the poorer-hearing ear without reducing head-shadow benefits and how these outcomes are influenced by interaural asymmetry in monaural speech recognition. DESIGN Speech-recognition thresholds for sentences in speech-shaped noise were measured for 6 adult SSD-CI listeners, 12 BI-CI listeners, and 9 normal-hearing listeners presented with vocoder simulations. Stimuli were presented using nonindividualized in-the-ear or behind-the-ear head-related impulse-response simulations with speech presented from a 70° azimuth (poorer-hearing side) and noise from 70° (better-hearing side), thereby yielding a better signal-to-noise ratio (SNR) at the poorer-hearing ear. Head-shadow benefit was computed as the improvement in bilateral speech-recognition thresholds gained from enabling the CI in the poorer-hearing, better-SNR ear. High- or low-pass filtering was systematically applied to the head-related impulse-response-filtered stimuli presented to the poorer-hearing ear. For the SSD-CI listeners and SSD-vocoder simulations, only high-pass filtering was applied, because the CI frequency allocation would never need to be adjusted downward to frequency-match the ears. For the BI-CI listeners and BI-vocoder simulations, both low and high pass filtering were applied. The normal-hearing listeners were tested with two levels of performance to examine the effect of interaural asymmetry in monaural speech recognition (vocoder synthesis-filter slopes: 5 or 20 dB/octave). RESULTS Mean head-shadow benefit was smaller for the SSD-CI listeners (~7 dB) than for the BI-CI listeners (~14 dB). For SSD-CI listeners, frequencies <1236 Hz could be excluded; for BI-CI listeners, frequencies <886 or >3814 Hz could be excluded from the poorer-hearing ear without reducing head-shadow benefit. Bilateral performance showed greater immunity to filtering than monaural performance, with gradual changes in performance as a function of filter cutoff. Real and vocoder-simulated CI users with larger interaural asymmetry in monaural performance had less head-shadow benefit. CONCLUSIONS The "exclusion frequency" ranges that could be removed without diminishing head-shadow benefit are interpreted in terms of low importance in the speech intelligibility index and a small head-shadow magnitude at low frequencies. Although groups and individuals with greater performance asymmetry gained less head-shadow benefit, the magnitudes of these factors did not predict the exclusion frequency range. Overall, these data suggest that for many SSD-CI and BI-CI listeners, the frequency allocation for the poorer-ear CI can be shifted substantially without sacrificing head-shadow benefit, at least for energetic maskers. Considering the two ears together as a single system may allow greater flexibility in discarding redundant frequency content from a CI in one ear when considering bilateral programming solutions aimed at reducing interaural frequency mismatch.
Collapse
|
20
|
刘 锦, 原 晶, 周 沫, 闫 占, 王 宁. [Rehabilitation of sound localization ability in patients with unilateral hearing loss or single-sided deafness]. LIN CHUANG ER BI YAN HOU TOU JING WAI KE ZA ZHI = JOURNAL OF CLINICAL OTORHINOLARYNGOLOGY, HEAD, AND NECK SURGERY 2021; 35:472-476;480. [PMID: 34304479 PMCID: PMC10128470 DOI: 10.13201/j.issn.2096-7993.2021.05.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 04/01/2021] [Indexed: 11/12/2022]
Abstract
The prevalence of unilateral hearing loss(UHL) is higher, and the clinical attention to the hearing rehabilitation of UHL is not enough, resulting in many UHL patients cannot get rehabilitation timely and effectively. Severe to profound UHL(also known as single-sided deafness) patients lack binaural hearing superiority, especially the inadequate ability of sound localization, which will seriously affect their daily life and academic performance. At present, the main rehabilitation methods of UHL include various kinds of bone conduction hearing aids, vibrant soundbridge and cochlear implantation, etc. However, the rehabilitation effect of UHL patients' ability to locate the sound source is affected by the occurrence age, the type, the degree and the duration of the hearing loss. The results of rehabilitation in different literature vary greatly. This paper reviews the effects of different rehabilitation strategies on the ability of sound location and analyzes its possible causes and mechanisms.
Collapse
Affiliation(s)
- 锦峰 刘
- 首都医科大学附属北京朝阳医院耳鼻咽喉头颈外科(北京,100020)
| | | | - 沫 周
- 首都医科大学附属北京朝阳医院耳鼻咽喉头颈外科(北京,100020)
| | | | - 宁宇 王
- 首都医科大学附属北京朝阳医院耳鼻咽喉头颈外科(北京,100020)
| |
Collapse
|
21
|
Yun D, Jennings TR, Kidd G, Goupell MJ. Benefits of triple acoustic beamforming during speech-on-speech masking and sound localization for bilateral cochlear-implant users. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:3052. [PMID: 34241104 PMCID: PMC8102069 DOI: 10.1121/10.0003933] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 03/03/2021] [Accepted: 03/06/2021] [Indexed: 05/30/2023]
Abstract
Bilateral cochlear-implant (CI) users struggle to understand speech in noisy environments despite receiving some spatial-hearing benefits. One potential solution is to provide acoustic beamforming. A headphone-based experiment was conducted to compare speech understanding under natural CI listening conditions and for two non-adaptive beamformers, one single beam and one binaural, called "triple beam," which provides an improved signal-to-noise ratio (beamforming benefit) and usable spatial cues by reintroducing interaural level differences. Speech reception thresholds (SRTs) for speech-on-speech masking were measured with target speech presented in front and two maskers in co-located or narrow/wide separations. Numerosity judgments and sound-localization performance also were measured. Natural spatial cues, single-beam, and triple-beam conditions were compared. For CI listeners, there was a negligible change in SRTs when comparing co-located to separated maskers for natural listening conditions. In contrast, there were 4.9- and 16.9-dB improvements in SRTs for the beamformer and 3.5- and 12.3-dB improvements for triple beam (narrow and wide separations). Similar results were found for normal-hearing listeners presented with vocoded stimuli. Single beam improved speech-on-speech masking performance but yielded poor sound localization. Triple beam improved speech-on-speech masking performance, albeit less than the single beam, and sound localization. Thus, triple beam was the most versatile across multiple spatial-hearing domains.
Collapse
Affiliation(s)
- David Yun
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Todd R Jennings
- Department of Speech, Language, and Hearing Sciences, Boston University, Boston, Massachusetts 02215, USA
| | - Gerald Kidd
- Department of Speech, Language, and Hearing Sciences, Boston University, Boston, Massachusetts 02215, USA
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| |
Collapse
|
22
|
Bilateral Cochlear Implants or Bimodal Hearing for Children with Bilateral Sensorineural Hearing Loss. CURRENT OTORHINOLARYNGOLOGY REPORTS 2021; 8:385-394. [PMID: 33815965 DOI: 10.1007/s40136-020-00314-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Purpose of review This review describes speech perception and language outcomes for children using bimodal hearing (cochlear implant (CI) plus contralateral hearing aid) as compared to children with bilateral CIs and contrasts said findings with the adult literature. There is a lack of clinical evidence driving recommendations for bimodal versus bilateral CI candidacy and as such, clinicians are often unsure about when to recommend a second CI for children with residual acoustic hearing. Thus the goal of this review is to identify scientific information that may influence clinical decision making for pediatric CI candidates with residual acoustic hearing. Recent findings Bilateral CIs are considered standard of care for children with bilateral severe-to-profound sensorineural hearing loss. For children with aidable acoustic hearing-even in just the low frequencies-an early period of bimodal stimulation has been associated with significantly better speech perception, vocabulary, and language development. HA audibility, however, is generally poorer than that offered by a CI resulting in interaural asymmetry in speech perception, head shadow, as well as brainstem and cortical activity and development. Thus there is a need to optimize "two-eared" hearing while maximizing a child's potential with respect to hearing, speech, and language while ensuring that we limit asymmetrically driven auditory neuroplasticity. A recent large study of bimodal and bilateral CI users suggested that a period of bimodal stimulation was only beneficial for children with a better-ear pure tone average (PTA) ≤ 73 dB HL. This 73-dB-HL cutoff applied even to children who ultimately received bilateral CIs. Summary Though we do not yet have definitive guidelines for determining bimodal versus bilateral CI candidacy, there is increasing evidence that 1) bilateral CIs yield superior outcomes for children with bilateral severe-to-profound hearing loss and, 2) an early period of bimodal stimulation is beneficial for speech perception and language development, but only for children with better-ear PTA ≤ 73 dB HL. For children with residual acoustic hearing, even in just the low-frequency range, rapid sequential bilateral cochlear implantation following a trial period with bimodal stimulation will yield best outcomes for auditory, language, and academic development. Of course, there is also an increasing prevalence of cochlear implantation with acoustic hearing preservation allowing for combined electric and acoustic stimulation even following bilateral implantation.
Collapse
|
23
|
Dichotic listening performance with cochlear-implant simulations of ear asymmetry is consistent with difficulty ignoring clearer speech. Atten Percept Psychophys 2021; 83:2083-2101. [PMID: 33782914 DOI: 10.3758/s13414-021-02244-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/07/2021] [Indexed: 11/08/2022]
Abstract
There are an increasing number of bilateral and single-sided-deafness cochlear-implant (CI) users who hope to achieve improved spatial-hearing abilities through access to sound in both ears. It is, however, unclear how speech is processed when inputs are functionally asymmetrical, which may have an impact on spatial-hearing abilities. Therefore, functionally asymmetrical hearing was controlled and parametrically manipulated using a channel vocoder as a CI simulation. In Experiment 1, normal-hearing (NH) listeners performed a dichotic listening task (i.e., selective attention to one ear, ignoring the other) using asymmetrical signal degradation. Spectral resolution varied independently in each ear (4, 8, 16 channels, and unprocessed control). Performance decreased with decreasing resolution in the target ear and increasing resolution in the interferer ear. In Experiment 2, these results were replicated using a divided attention task (attend to both ears, report one after sentence completion) in both NH and bilateral CI listeners, although overall performance was lower than in Experiment 1. In Experiment 3, frequency-to-place mismatch simulated shallow CI insertion depths (0, 3, 6-mm shifts, and unprocessed control). Performance mostly decreased with increasing shift in the target ear and decreasing shift in the interferer ear; however, performance nonmonotonicities occurred. The worst performance occurred when the shift matched across ears, suggesting that pitch similarity increases difficulty. The results show that it is more difficult to attend an ear that is relatively degraded or distorted, which may set spatial-hearing limitations for CI users when trying to attend to a target in complex auditory scenes.
Collapse
|
24
|
Kan A, Meng Q. The Temporal Limits Encoder as a Sound Coding Strategy for Bilateral Cochlear Implants. IEEE/ACM TRANSACTIONS ON AUDIO, SPEECH, AND LANGUAGE PROCESSING 2020; 29:265-273. [PMID: 33409339 PMCID: PMC7781292 DOI: 10.1109/taslp.2020.3039601] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
The difference in binaural benefit between bilateral cochlear implant (CI) users and normal hearing (NH) listeners has typically been attributed to CI sound coding strategies not encoding the acoustic fine structure (FS) interaural time differences (ITD). The Temporal Limits Encoder (TLE) strategy is proposed as a potential way of improving binaural hearing benefits for CI users in noisy situations. TLE works by downward-transposition of mid-frequency band-limited channel information and can theoretically provide FS-ITD cues. In this work, the effect of choice of lower limit of the modulator in TLE was examined by measuring performance on a word recognition task and computing the magnitude of binaural benefit in bilateral CI users. Performance listening with the TLE strategy was compared with the commonly used Advanced Combinational Encoder (ACE) CI sound coding strategy. Results showed that setting the lower limit to ≥200 Hz maintained word recognition performance comparable to that of ACE. While most CI listeners exhibited a large binaural benefit (≥6 dB) in at least one of the conditions tested, there was no systematic relationship between the lower limit of the modulator and performance. These results indicate that the TLE strategy has potential to improve binaural hearing abilities in CI users but further work is needed to understand how binaural benefit can be maximized.
Collapse
Affiliation(s)
- Alan Kan
- Waisman Center, University of Wisconsin-Madison at the time this work was conducted. He is now with the School of Engineering, Macquarie University, NSW, Australia, 2109
| | - Qinglin Meng
- Acoustics Laboratory, School of Physics and Optoelectronics, South China University of Technology, Guangzhou, China, 510641
| |
Collapse
|
25
|
D'Onofrio K, Richards V, Gifford R. Spatial Release From Informational and Energetic Masking in Bimodal and Bilateral Cochlear Implant Users. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2020; 63:3816-3833. [PMID: 33049147 PMCID: PMC8582905 DOI: 10.1044/2020_jslhr-20-00044] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 04/27/2020] [Accepted: 07/24/2020] [Indexed: 06/11/2023]
Abstract
Purpose Spatially separating speech and background noise improves speech understanding in normal-hearing listeners, an effect referred to as spatial release from masking (SRM). In cochlear implant (CI) users, SRM has often been demonstrated using asymmetric noise configurations, which maximize benefit from head shadow and the potential availability of binaural cues. In contrast, SRM in symmetrical configurations has been minimal to absent in CI users. We examined the interaction between two types of maskers (informational and energetic) and SRM in bimodal and bilateral CI users. We hypothesized that SRM would be absent or "negative" using symmetrically separated noise maskers. Second, we hypothesized that bimodal listeners would exhibit greater release from informational masking due to access to acoustic information in the non-CI ear. Method Participants included 10 bimodal and 10 bilateral CI users. Speech understanding in noise was tested in 24 conditions: 3 spatial configurations (S0N0, S0N45&315, S0N90&270) × 2 masker types (speech, signal-correlated noise) × 2 listening configurations (best-aided, CI-alone) × 2 talker gender conditions (different-gender, same-gender). Results In support of our first hypothesis, both groups exhibited negative SRM with increasing spatial separation. In opposition to our second hypothesis, both groups exhibited similar magnitudes of release from informational masking. The magnitude of release was greater for bimodal listeners, though this difference failed to reach statistical significance. Conclusions Both bimodal and bilateral CI recipients exhibited negative SRM. This finding is consistent with CI signal processing limitations, the audiologic factors associated with SRM, and known effects of behind-the-ear microphone technology. Though release from informational masking was not significantly different across groups, the magnitude of release was greater for bimodal listeners. This suggests that bimodal listeners may be at least marginally more susceptible to informational masking than bilateral CI users, though further research is warranted.
Collapse
Affiliation(s)
- Kristen D'Onofrio
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| | | | - René Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| |
Collapse
|
26
|
Zhang Z, Wei C, Zhang Y, Zeng Z, Cao K, Liu Y. Sequential Bilateral Cochlear Implantation With Prolonged Time Intervals. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2020; 63:3195-3207. [PMID: 32857631 DOI: 10.1044/2020_jslhr-20-00140] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Purpose The aim of the study was to assess whether sequential cochlear implantation (CI) with a prolonged interimplant interval (M = 15.2 years) between the first and second CIs benefited speech recognition and health-related quality of life. Method This prospective study included 14 prelingually deafened participants who received their second CI after a prolonged interimplant interval (M = 15.2 years). Additionally, speech recognition ability over a 12-month period of bilateral implant use was investigated. The results of the speech recognition test in both quiet and noisy conditions were statistically analyzed for each CI alone and both CIs together. Nijmegen Cochlear Implant Questionnaire scores were also collected at activation and at 12 months after activation. Results Improvements in speech recognition ability were observed following the use of the first implant alone and with the use of both implants together; however, progress was much slower with the use of the second implant alone, following its introduction. Furthermore, a significant difference in the trajectory of speech recognition ability was observed between the first and the second implanted ear. According to Nijmegen Cochlear Implant Questionnaire scores, all participants benefitted from bilateral CI after 12 months. Conclusions Prolonged interimplant intervals resulted in asymmetrical speech recognition abilities. A significant improvement in the speech recognition scores was observed with the first implanted ear, and much slower progress was observed with the second implanted ear. However, the "poorer" second implanted ear could provide a considerable beneficial effect on the improved speech recognition and health-related quality of life with the bilateral CI. Supplemental Material https://doi.org/10.23641/asha.12861152.
Collapse
Affiliation(s)
- Zhikai Zhang
- Department of Otolaryngology, Head and Neck Surgery, Peking University First Hospital, Beijing, China
| | - Chaogang Wei
- Department of Otolaryngology, Head and Neck Surgery, Peking University First Hospital, Beijing, China
| | - Yanmei Zhang
- Department of Otolaryngology, Head and Neck Surgery, Peking University First Hospital, Beijing, China
| | - Zhengang Zeng
- Department of Otolaryngology, Head and Neck Surgery, Peking University First Hospital, Beijing, China
| | - Keli Cao
- Department of Otorhinolaryngology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences Peking Union Medical College, Beijing, China
| | - Yuhe Liu
- Department of Otolaryngology, Head and Neck Surgery, Peking University First Hospital, Beijing, China
| |
Collapse
|
27
|
Misurelli SM, Goupell MJ, Burg EA, Jocewicz R, Kan A, Litovsky RY. Auditory Attention and Spatial Unmasking in Children With Cochlear Implants. Trends Hear 2020; 24:2331216520946983. [PMID: 32812515 PMCID: PMC7446264 DOI: 10.1177/2331216520946983] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
The ability to attend to target speech in background noise is an important skill, particularly for children who spend many hours in noisy environments. Intelligibility improves as a result of spatial or binaural unmasking in the free-field for normal-hearing children; however, children who use bilateral cochlear implants (BiCIs) demonstrate little benefit in similar situations. It was hypothesized that poor auditory attention abilities might explain the lack of unmasking observed in children with BiCIs. Target and interferer speech stimuli were presented to either or both ears of BiCI participants via their clinical processors. Speech reception thresholds remained low when the target and interferer were in opposite ears, but they did not show binaural unmasking when the interferer was presented to both ears and the target only to one ear. These results demonstrate that, in the most extreme cases of stimulus separation, children with BiCIs can ignore an interferer and attend to target speech, but there is weak or absent binaural unmasking. It appears that children with BiCIs mostly experience poor encoding of binaural cues rather than deficits in ability to selectively attend to target speech.
Collapse
Affiliation(s)
- Sara M Misurelli
- Waisman Center, University of Wisconsin-Madison.,Department of Surgery, Division of Otolaryngology, University of Wisconsin School of Medicine and Public Health
| | | | | | | | - Alan Kan
- Waisman Center, University of Wisconsin-Madison.,School of Engineering, Macquarie University, Sydney, Australia
| | - Ruth Y Litovsky
- Waisman Center, University of Wisconsin-Madison.,Department of Surgery, Division of Otolaryngology, University of Wisconsin School of Medicine and Public Health
| |
Collapse
|
28
|
Anderson SR, Easter K, Goupell MJ. Effects of rate and age in processing interaural time and level differences in normal-hearing and bilateral cochlear-implant listeners. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:3232. [PMID: 31795662 PMCID: PMC6948219 DOI: 10.1121/1.5130384] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 09/27/2019] [Accepted: 10/02/2019] [Indexed: 05/25/2023]
Abstract
Bilateral cochlear implants (BICIs) provide improved sound localization and speech understanding in noise compared to unilateral CIs. However, normal-hearing (NH) listeners demonstrate superior binaural processing abilities compared to BICI listeners. This investigation sought to understand differences between NH and BICI listeners' processing of interaural time differences (ITDs) and interaural level differences (ILDs) as a function of fine-structure and envelope rate using an intracranial lateralization task. The NH listeners were presented band-limited acoustical pulse trains and sinusoidally amplitude-modulated tones using headphones, and the BICI listeners were presented single-electrode electrical pulse trains using direct stimulation. Lateralization range increased as fine-structure rate increased for ILDs in BICI listeners. Lateralization range decreased for rates above 100 Hz for fine-structure ITDs, but decreased for rates lower or higher than 100 Hz for envelope ITDs in both groups. Lateralization ranges for ITDs were smaller for BICI listeners on average. After controlling for age, older listeners showed smaller lateralization ranges and BICI listeners had a more rapid decline for ITD sensitivity at 300 pulses per second. This work suggests that age confounds comparisons between NH and BICI listeners in temporal processing tasks and that some NH-BICI binaural processing differences persist even when age differences are adequately addressed.
Collapse
Affiliation(s)
- Sean R Anderson
- Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Kyle Easter
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| |
Collapse
|
29
|
Chen Y, Chen W, Zhang P, Chen P. [Research progress of microphone array based front-end speech enhancement technology for cochlear implant]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2019; 36:696-704. [PMID: 31441274 PMCID: PMC10319500 DOI: 10.7507/1001-5515.201805050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Indexed: 11/03/2022]
Abstract
Microphone array based methods are gradually applied in the front-end speech enhancement and speech recognition improvement for cochlear implant in recent years. By placing several microphones in different locations in space, this method can collect multi-channel signals containing a lot of spatial position and orientation information. Microphone array can also yield specific beamforming mode to enhance desired signal and suppress ambient noise, which is particularly suitable to be applied in face-to-face conversation for cochlear implant users. And its application value has attracted more and more attention from researchers. In this paper, we describe the principle of microphone array method, analyze the microphone array based speech enhancement technologies in present literature, and further present the technical difficulties and development trend.
Collapse
Affiliation(s)
- Yousheng Chen
- Shenzhen Institute of Information Technology, Shenzhen, Guangdong 518000,
| | - Weifang Chen
- Shenzhen Institute of Information Technology, Shenzhen, Guangdong 518000, P.R.China
| | - Pu Zhang
- Shenzhen Institute of Information Technology, Shenzhen, Guangdong 518000, P.R.China
| | - Peipei Chen
- Shenzhen Institute of Information Technology, Shenzhen, Guangdong 518000, P.R.China
| |
Collapse
|
30
|
Anderson SR, Kan A, Litovsky RY. Asymmetric temporal envelope encoding: Implications for within- and across-ear envelope comparison. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:1189. [PMID: 31472559 PMCID: PMC7051005 DOI: 10.1121/1.5121423] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2018] [Revised: 07/24/2019] [Accepted: 07/24/2019] [Indexed: 05/17/2023]
Abstract
Separating sound sources in acoustic environments relies on making ongoing, highly accurate spectro-temporal comparisons. However, listeners with hearing impairment may have varying quality of temporal encoding within or across ears, which may limit the listeners' ability to make spectro-temporal comparisons between places-of-stimulation. In this study in normal hearing listeners, depth of amplitude modulation (AM) for sinusoidally amplitude modulated (SAM) tones was manipulated in an effort to reduce the coding of periodicity in the auditory nerve. The ability to judge differences in AM rates was studied for stimuli presented to different cochlear places-of-stimulation, within- or across-ears. It was hypothesized that if temporal encoding was poorer for one tone in a pair, then sensitivity to differences in AM rate of the pair would decrease. Results indicated that when the depth of AM was reduced from 50% to 20% for one SAM tone in a pair, sensitivity to differences in AM rate decreased. Sensitivity was greatest for AM rates near 90 Hz and depended upon the places-of-stimulation being compared. These results suggest that degraded temporal representations in the auditory nerve for one place-of-stimulation could lead to deficits comparing that temporal information with other places-of-stimulation.
Collapse
Affiliation(s)
- Sean R Anderson
- Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Alan Kan
- Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Ruth Y Litovsky
- Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| |
Collapse
|
31
|
The Effect of Simulated Interaural Frequency Mismatch on Speech Understanding and Spatial Release From Masking. Ear Hear 2019; 39:895-905. [PMID: 29337763 DOI: 10.1097/aud.0000000000000541] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The binaural-hearing system interaurally compares inputs, which underlies the ability to localize sound sources and to better understand speech in complex acoustic environments. Cochlear implants (CIs) are provided in both ears to increase binaural-hearing benefits; however, bilateral CI users continue to struggle with understanding speech in the presence of interfering sounds and do not achieve the same level of spatial release from masking (SRM) as normal-hearing listeners. One reason for diminished SRM in CI users could be that the electrode arrays are inserted at different depths in each ear, which would cause an interaural frequency mismatch. Because interaural frequency mismatch diminishes the salience of interaural differences for relatively simple stimuli, it may also diminish binaural benefits for spectral-temporally complex stimuli like speech. This study evaluated the effect of simulated frequency-to-place mismatch on speech understanding and SRM. DESIGN Eleven normal-hearing listeners were tested on a speech understanding task. There was a female target talker who spoke five-word sentences from a closed set of words. There were two interfering male talkers who spoke unrelated sentences. Nonindividualized head-related transfer functions were used to simulate a virtual auditory space. The target was presented from the front (0°), and the interfering speech was either presented from the front (colocated) or from 90° to the right (spatially separated). Stimuli were then processed by an eight-channel vocoder with tonal carriers to simulate aspects of listening through a CI. Frequency-to-place mismatch ("shift") was introduced by increasing the center frequency of the synthesis filters compared with the corresponding analysis filters. Speech understanding was measured for different shifts (0, 3, 4.5, and 6 mm) and target-to-masker ratios (TMRs: +10 to -10 dB). SRM was calculated as the difference in the percentage of correct words for the colocated and separated conditions. Two types of shifts were tested: (1) bilateral shifts that had the same frequency-to-place mismatch in both ears, but no interaural frequency mismatch, and (2) unilateral shifts that produced an interaural frequency mismatch. RESULTS For the bilateral shift conditions, speech understanding decreased with increasing shift and with decreasing TMR, for both colocated and separate conditions. There was, however, no interaction between shift and spatial configuration; in other words, SRM was not affected by shift. For the unilateral shift conditions, speech understanding decreased with increasing interaural mismatch and with decreasing TMR for both the colocated and spatially separated conditions. Critically, there was a significant interaction between the amount of shift and spatial configuration; in other words, SRM decreased for increasing interaural mismatch. CONCLUSIONS A frequency-to-place mismatch in one or both ears resulted in decreased speech understanding. SRM, however, was only affected in conditions with unilateral shifts and interaural frequency mismatch. Therefore, matching frequency information between the ears provides listeners with larger binaural-hearing benefits, for example, improved speech understanding in the presence of interfering talkers. A clinical procedure to reduce interaural frequency mismatch when programming bilateral CIs may improve benefits in speech segregation that are due to binaural-hearing abilities.
Collapse
|