1
|
Jahn KN, Wiegand-Shahani BM, Moturi V, Kashiwagura ST, Doak KR. Cochlear-implant simulated spectral degradation attenuates emotional responses to environmental sounds. Int J Audiol 2024:1-7. [PMID: 39146030 DOI: 10.1080/14992027.2024.2385552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 07/22/2024] [Indexed: 08/17/2024]
Abstract
OBJECTIVE Cochlear implants (CI) provide users with a spectrally degraded acoustic signal that could impact their auditory emotional experiences. This study evaluated the effects of CI-simulated spectral degradation on emotional valence and arousal elicited by environmental sounds. DESIGN Thirty emotionally evocative sounds were filtered through a noise-band vocoder. Participants rated the perceived valence and arousal elicited by each of the full-spectrum and vocoded stimuli. These ratings were compared across acoustic conditions (full-spectrum, vocoded) and as a function of stimulus type (unpleasant, neutral, pleasant). STUDY SAMPLE Twenty-five young adults (age 19 to 34 years) with normal hearing. RESULTS Emotional responses were less extreme for spectrally degraded (i.e., vocoded) sounds than for full-spectrum sounds. Specifically, spectrally degraded stimuli were perceived as more negative and less arousing than full-spectrum stimuli. CONCLUSION By meticulously replicating CI spectral degradation while controlling for variables that are confounded within CI users, these findings indicate that CI spectral degradation can compress the range of sound-induced emotion independent of hearing loss and other idiosyncratic device- or person-level variables. Future work will characterize emotional reactions to sound in CI users via objective, psychoacoustic, and subjective measures.
Collapse
Affiliation(s)
- Kelly N Jahn
- Department of Speech, Language, and Hearing, The University of Texas at Dallas, Richardson, TX, USA
- Callier Center for Communication Disorders, The University of Texas at Dallas, Dallas, TX, USA
| | - Braden M Wiegand-Shahani
- Department of Speech, Language, and Hearing, The University of Texas at Dallas, Richardson, TX, USA
- Callier Center for Communication Disorders, The University of Texas at Dallas, Dallas, TX, USA
| | - Vaishnavi Moturi
- Department of Speech, Language, and Hearing, The University of Texas at Dallas, Richardson, TX, USA
| | - Sean Takamoto Kashiwagura
- Department of Speech, Language, and Hearing, The University of Texas at Dallas, Richardson, TX, USA
- Callier Center for Communication Disorders, The University of Texas at Dallas, Dallas, TX, USA
| | - Karlee R Doak
- Department of Speech, Language, and Hearing, The University of Texas at Dallas, Richardson, TX, USA
- Callier Center for Communication Disorders, The University of Texas at Dallas, Dallas, TX, USA
| |
Collapse
|
2
|
Skidmore J, Yuan Y, He S. A new method for removing artifacts from recordings of the electrically evoked compound action potential: Single-pulse stimulation. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2024:2024.01.17.24301435. [PMID: 38293121 PMCID: PMC10827261 DOI: 10.1101/2024.01.17.24301435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2024]
Abstract
This report presents a new method for removing electrical artifact contamination from the electrically evoked compound action potential (eCAP) evoked by single cathodic-leading, biphasic-pulse stimulation. The development of the new method is motivated by results recorded in human cochlear implant (CI) users showing that the fundamental assumption of the classic forward masking artifact rejection technique is violated in up to 45% of cases tested at high stimulation levels when using default stimulation parameters. Subsequently, the new method developed based on the discovery that a hyperbola best characterizes the artifacts created during stimulation and recording is described. The eCAP waveforms obtained using the new method are compared to those recorded using the classic forward masking technique. The results show that eCAP waveforms obtained using both methods are comparable when the fundamental assumption of the classic forward masking technique is met. In contrast, eCAP amplitudes obtained using the two methods are significantly different when the fundamental assumption of the classic forward masking technique is violated, with greater differences in the eCAP amplitude for greater assumption violations. The new method also has excellent test-retest reliability (Intraclass correlation > 0.98). Overall, the new method is a viable alternative to the classic forward masking technique for obtaining artifact-free eCAPs evoked by single-pulse stimulation in CI users.
Collapse
Affiliation(s)
- Jeffrey Skidmore
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212, USA
| | - Yi Yuan
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212, USA
| | - Shuman He
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212, USA
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205, USA
| |
Collapse
|
3
|
Schvartz-Leyzac KC, Colesa DJ, Swiderski DL, Raphael Y, Pfingst BE. Cochlear Health and Cochlear-implant Function. J Assoc Res Otolaryngol 2023; 24:5-29. [PMID: 36600147 PMCID: PMC9971430 DOI: 10.1007/s10162-022-00882-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 11/24/2022] [Indexed: 01/06/2023] Open
Abstract
The cochlear implant (CI) is widely considered to be one of the most innovative and successful neuroprosthetic treatments developed to date. Although outcomes vary, CIs are able to effectively improve hearing in nearly all recipients and can substantially improve speech understanding and quality of life for patients with significant hearing loss. A wealth of research has focused on underlying factors that contribute to success with a CI, and recent evidence suggests that the overall health of the cochlea could potentially play a larger role than previously recognized. This article defines and reviews attributes of cochlear health and describes procedures to evaluate cochlear health in humans and animal models in order to examine the effects of cochlear health on performance with a CI. Lastly, we describe how future biologic approaches can be used to preserve and/or enhance cochlear health in order to maximize performance for individual CI recipients.
Collapse
Affiliation(s)
- Kara C Schvartz-Leyzac
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, 135 Rutledge Ave, Charleston, SC, 29425, USA
| | - Deborah J Colesa
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Donald L Swiderski
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Yehoash Raphael
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Bryan E Pfingst
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA.
| |
Collapse
|
4
|
Guevara N, Truy E, Hoen M, Hermann R, Vandersteen C, Gallego S. Electrical Field Interactions during Adjacent Electrode Stimulations: eABR Evaluation in Cochlear Implant Users. J Clin Med 2023; 12:jcm12020605. [PMID: 36675534 PMCID: PMC9865217 DOI: 10.3390/jcm12020605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/06/2023] [Accepted: 01/10/2023] [Indexed: 01/15/2023] Open
Abstract
The present study investigates how electrically evoked Auditory Brainstem Responses (eABRs) can be used to measure local channel interactions along cochlear implant (CI) electrode arrays. eABRs were recorded from 16 experienced CI patients in response to electrical pulse trains delivered using three stimulation configurations: (1) single electrode stimulations (E11 or E13); (2) simultaneous stimulation from two electrodes separated by one (En and En+2, E11 and E13); and (3) stimulations from three consecutive electrodes (E11, E12, and E13). Stimulation level was kept constant at 70% electrical dynamic range (EDR) on the two flanking electrodes (E11 and E13) and was varied from 0 to 100% EDR on the middle electrode (E12). We hypothesized that increasing the middle electrode stimulation level would cause increasing local electrical interactions, reflected in characteristics of the evoked compound eABR. Results show that group averaged eABR wave III and V latency and amplitude were reduced when stimulation level at the middle electrode was increased, in particular when stimulation level on E12 reached 40, 70, and 100% EDR. Compound eABRs can provide a detailed individual quantification of electrical interactions occurring at specific electrodes along the CI electrode array. This approach allows a fine determination of interactions at the single electrode level potentially informing audiological decisions regarding mapping of CI systems.
Collapse
Affiliation(s)
- Nicolas Guevara
- Institut Universitaire de la Face et du Cou, Centre Hospitalier Universitaire de Nice, Université Côte d’Azur, 06100 Nice, France
| | - Eric Truy
- Department of Audiology and Otorhinolaryngology, Edouard Herriot Hospital, Lyon 1 University, 69437 Lyon, France
| | - Michel Hoen
- Clinical Evidence Department, Oticon Medical, 06220 Vallauris, France
- Correspondence:
| | - Ruben Hermann
- Department of Audiology and Otorhinolaryngology, Edouard Herriot Hospital, Lyon 1 University, 69437 Lyon, France
| | - Clair Vandersteen
- Institut Universitaire de la Face et du Cou, Centre Hospitalier Universitaire de Nice, Université Côte d’Azur, 06100 Nice, France
| | - Stéphane Gallego
- Institute for Readaptation Sciences and Techniques, Lyon 1 University, 69373 Lyon, France
| |
Collapse
|
5
|
Söderqvist S, Sinkkonen ST, Sivonen V. The intraoperative relationship between intracochlear electrical field and excitability of the auditory nerve. Heliyon 2022; 8:e11970. [DOI: 10.1016/j.heliyon.2022.e11970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 10/10/2022] [Accepted: 11/22/2022] [Indexed: 12/03/2022] Open
|
6
|
Comparison of response properties of the electrically stimulated auditory nerve reported in human listeners and in animal models. Hear Res 2022; 426:108643. [PMID: 36343534 PMCID: PMC9986845 DOI: 10.1016/j.heares.2022.108643] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 09/29/2022] [Accepted: 10/20/2022] [Indexed: 11/04/2022]
Abstract
Cochlear implants (CIs) provide acoustic information to implanted patients by electrically stimulating nearby auditory nerve fibers (ANFs) which then transmit the information to higher-level neural structures for further processing and interpretation. Computational models that simulate ANF responses to CI stimuli enable the exploration of the mechanisms underlying CI performance beyond the capacity of in vivo experimentation alone. However, all ANF models developed to date utilize to some extent anatomical/morphometric data, biophysical properties and/or physiological data measured in non-human animal models. This review compares response properties of the electrically stimulated auditory nerve (AN) in human listeners and different mammalian models. Properties of AN responses to single pulse stimulation, paired-pulse stimulation, and pulse-train stimulation are presented. While some AN response properties are similar between human listeners and animal models (e.g., increased AN sensitivity to single pulse stimuli with long interphase gaps), there are some significant differences. For example, the AN of most animal models is typically more sensitive to cathodic stimulation while the AN of human listeners is generally more sensitive to anodic stimulation. Additionally, there are substantial differences in the speed of recovery from neural adaptation between animal models and human listeners. Therefore, results from animal models cannot be simply translated to human listeners. Recognizing the differences in responses of the AN to electrical stimulation between humans and other mammals is an important step for creating ANF models that are more applicable to various human CI patient populations.
Collapse
|
7
|
Tinnemore AR, Montero L, Gordon-Salant S, Goupell MJ. The recognition of time-compressed speech as a function of age in listeners with cochlear implants or normal hearing. Front Aging Neurosci 2022; 14:887581. [PMID: 36247992 PMCID: PMC9557069 DOI: 10.3389/fnagi.2022.887581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 08/29/2022] [Indexed: 11/13/2022] Open
Abstract
Speech recognition is diminished when a listener has an auditory temporal processing deficit. Such deficits occur in listeners over 65 years old with normal hearing (NH) and with age-related hearing loss, but their source is still unclear. These deficits may be especially apparent when speech occurs at a rapid rate and when a listener is mostly reliant on temporal information to recognize speech, such as when listening with a cochlear implant (CI) or to vocoded speech (a CI simulation). Assessment of the auditory temporal processing abilities of adults with CIs across a wide range of ages should better reveal central or cognitive sources of age-related deficits with rapid speech because CI stimulation bypasses much of the cochlear encoding that is affected by age-related peripheral hearing loss. This study used time-compressed speech at four different degrees of time compression (0, 20, 40, and 60%) to challenge the auditory temporal processing abilities of younger, middle-aged, and older listeners with CIs or with NH. Listeners with NH were presented vocoded speech at four degrees of spectral resolution (unprocessed, 16, 8, and 4 channels). Results showed an interaction between age and degree of time compression. The reduction in speech recognition associated with faster rates of speech was greater for older adults than younger adults. The performance of the middle-aged listeners was more similar to that of the older listeners than to that of the younger listeners, especially at higher degrees of time compression. A measure of cognitive processing speed did not predict the effects of time compression. These results suggest that central auditory changes related to the aging process are at least partially responsible for the auditory temporal processing deficits seen in older listeners, rather than solely peripheral age-related changes.
Collapse
Affiliation(s)
- Anna R. Tinnemore
- Neuroscience and Cognitive Science Program, University of Maryland, College Park, College Park, MD, United States
- Department of Hearing and Speech Sciences, University of Maryland, College Park, College Park, MD, United States
- *Correspondence: Anna R. Tinnemore,
| | - Lauren Montero
- Department of Hearing and Speech Sciences, University of Maryland, College Park, College Park, MD, United States
| | - Sandra Gordon-Salant
- Neuroscience and Cognitive Science Program, University of Maryland, College Park, College Park, MD, United States
- Department of Hearing and Speech Sciences, University of Maryland, College Park, College Park, MD, United States
| | - Matthew J. Goupell
- Neuroscience and Cognitive Science Program, University of Maryland, College Park, College Park, MD, United States
- Department of Hearing and Speech Sciences, University of Maryland, College Park, College Park, MD, United States
| |
Collapse
|
8
|
Li MM, Moberly AC, Tamati TN. Factors affecting talker discrimination ability in adult cochlear implant users. JOURNAL OF COMMUNICATION DISORDERS 2022; 99:106255. [PMID: 35988314 PMCID: PMC10659049 DOI: 10.1016/j.jcomdis.2022.106255] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 08/10/2022] [Accepted: 08/11/2022] [Indexed: 06/15/2023]
Abstract
INTRODUCTION Real-world speech communication involves interacting with many talkers with diverse voices and accents. Many adults with cochlear implants (CIs) demonstrate poor talker discrimination, which may contribute to real-world communication difficulties. However, the factors contributing to talker discrimination ability, and how discrimination ability relates to speech recognition outcomes in adult CI users are still unknown. The current study investigated talker discrimination ability in adult CI users, and the contributions of age, auditory sensitivity, and neurocognitive skills. In addition, the relation between talker discrimination ability and multiple-talker sentence recognition was explored. METHODS Fourteen post-lingually deaf adult CI users (3 female, 11 male) with ≥1 year of CI use completed a talker discrimination task. Participants listened to two monosyllabic English words, produced by the same talker or by two different talkers, and indicated if the words were produced by the same or different talkers. Nine female and nine male native English talkers were paired, resulting in same- and different-talker pairs as well as same-gender and mixed-gender pairs. Participants also completed measures of spectro-temporal processing, neurocognitive skills, and multiple-talker sentence recognition. RESULTS CI users showed poor same-gender talker discrimination, but relatively good mixed-gender talker discrimination. Older age and weaker neurocognitive skills, in particular inhibitory control, were associated with less accurate mixed-gender talker discrimination. Same-gender discrimination was significantly related to multiple-talker sentence recognition accuracy. CONCLUSION Adult CI users demonstrate overall poor talker discrimination ability. Individual differences in mixed-gender discrimination ability were related to age and neurocognitive skills, suggesting that these factors contribute to the ability to make use of available, degraded talker characteristics. Same-gender talker discrimination was associated with multiple-talker sentence recognition, suggesting that access to subtle talker-specific cues may be important for speech recognition in challenging listening conditions.
Collapse
Affiliation(s)
- Michael M Li
- The Ohio State University Wexner Medical Center, Department of Otolaryngology - Head & Neck Surgery, Columbus, OH, USA
| | - Aaron C Moberly
- The Ohio State University Wexner Medical Center, Department of Otolaryngology - Head & Neck Surgery, Columbus, OH, USA
| | - Terrin N Tamati
- The Ohio State University Wexner Medical Center, Department of Otolaryngology - Head & Neck Surgery, Columbus, OH, USA; University Medical Center Groningen, University of Groningen, Department of Otorhinolaryngology/Head and Neck Surgery, Groningen, the Netherlands.
| |
Collapse
|
9
|
He S, Skidmore J, Conroy S, Riggs WJ, Carter BL, Xie R. Neural Adaptation of the Electrically Stimulated Auditory Nerve Is Not Affected by Advanced Age in Postlingually Deafened, Middle-aged, and Elderly Adult Cochlear Implant Users. Ear Hear 2022; 43:1228-1244. [PMID: 34999595 PMCID: PMC9232840 DOI: 10.1097/aud.0000000000001184] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
OBJECTIVE This study aimed to investigate the associations between advanced age and the amount and the speed of neural adaptation of the electrically stimulated auditory nerve (AN) in postlingually deafened adult cochlear implant (CI) users. DESIGN Study participants included 26 postlingually deafened adult CI users, ranging in age between 28.7 and 84.0 years (mean: 63.8 years, SD: 14.4 years) at the time of testing. All study participants used a Cochlear Nucleus device with a full electrode array insertion in the test ear. The stimulus was a 100-ms pulse train with a pulse rate of 500, 900, 1800, or 2400 pulses per second (pps) per channel. The stimulus was presented at the maximum comfortable level measured at 2400 pps with a presentation rate of 2 Hz. Neural adaptation of the AN was evaluated using electrophysiological measures of the electrically evoked compound action potential (eCAP). The amount of neural adaptation was quantified by the adaptation index (AI) within three time windows: around 0 to 8 ms (window 1), 44 to 50 ms (window 2), and 94 to 100 ms (window 3). The speed of neural adaptation was quantified using a two-parameter power law estimation. In 23 participants, four electrodes across the electrode array were tested. In three participants, three electrodes were tested. Results measured at different electrode locations were averaged for each participant at each pulse rate to get an overall representation of neural adaptation properties of the AN across the cochlea. Linear-mixed models (LMMs) were used (1) to evaluate the effects of age at testing and pulse rate on the speed of neural adaptation and (2) to assess the effects of age at testing, pulse rate, and duration of stimulation (i.e., time window) on the amount of neural adaptation in these participants. RESULTS There was substantial variability in both the amount and the speed of neural adaptation of the AN among study participants. The amount and the speed of neural adaptation increased at higher pulse rates. In addition, larger amounts of adaptation were observed for longer durations of stimulation. There was no significant effect of age on the speed or the amount of neural adaptation. CONCLUSIONS The amount and the speed of neural adaptation of the AN are affected by both the pulse rate and the duration of stimulation, with higher pulse rates and longer durations of stimulation leading to faster and greater neural adaptation. Advanced age does not affect neural adaptation of the AN in postlingually deafened, middle-aged and elderly adult CI users.
Collapse
Affiliation(s)
- Shuman He
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Jeffrey Skidmore
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Sara Conroy
- Center for Biostatistics, Department of Bioinformatics, The Ohio State University, 1800 Cannon Drive, Columbus, OH 43210
| | - William J. Riggs
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Brittney L. Carter
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Ruili Xie
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| |
Collapse
|
10
|
Söderqvist S, Sivonen V, Lamminmäki S, Ylönen J, Markkola A, Sinkkonen ST. Investigating the association of electrically-evoked compound action potential thresholds with inner-ear dimensions in pediatric cochlear implantation. Int J Pediatr Otorhinolaryngol 2022; 158:111160. [PMID: 35544967 DOI: 10.1016/j.ijporl.2022.111160] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 03/12/2022] [Accepted: 04/23/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVES A narrow bony cochlear nerve canal (BCNC), as well as a hypoplastic and aplastic cochlear nerve (CN) have been associated with increased electrically-evoked compound action potential (eCAP) thresholds in some studies, suggesting poorer neural excitability in cochlear implantation. Also, in large cochleae the extent of activated spiral ganglion neurons with electrical stimulation is less than in smaller ones. However, a detailed description of the relationship between eCAP thresholds for a lateral-wall electrode array and dimensions of the inner-ear structures and internal auditory canal (IAC) is missing. DESIGN The study subjects were 52 pediatric patients with congenital severe-to-profound hearing loss (27 females and 25 males; ages 0.7-2.0 years; 1.0 ± 0.3 years, mean ± SD) implanted bilaterally with Cochlear Nucleus CI422, CI522, or CI622 implants with full insertion of the Slim Straight electrode array. Diameters of the cochlea and the BCNC as well as the widths and heights of the IAC and the CN were evaluated from preoperative computed tomography and magnetic resonance images. These anatomical dimensions were compared with each other and with the patients' intraoperative eCAP thresholds. RESULTS The eCAP thresholds increased from the apical to basal direction (r = 0.89, p < 0.001). After sorting the cochleae into four size categories, higher eCAP thresholds were found in larger than in smaller cochleae (p < 0.001). With similar categorization, the eCAP thresholds were higher in cochleae with a larger BCNC than in cochleae with a smaller BCNC (p < 0.001). Neither IAC nor CN cross-sectional areas affected the eCAP thresholds. Correlations were found between cochlea and BCNC diameters and between IAC and CN cross-sectional areas (r = 0.39 and r = 0.48, respectively, p < 0.001 for both). CONCLUSIONS In the basal part of the electrode array, higher stimulation levels to elicit measurable neural responses (eCAP thresholds) were required than in the apical part. Increased eCAP thresholds associated with a larger cochlear diameter, but contrary to the earlier studies, not with a small size of the BCNC or the CN. Instead, the BCNC diameter correlated significantly with the cochlea diameter.
Collapse
Affiliation(s)
- Samuel Söderqvist
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
| | - Ville Sivonen
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - Satu Lamminmäki
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - Jere Ylönen
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland; Department of Otorhinolaryngology, Päijät-Häme Central Hospital, Päijät-Häme Joint Authority for Health and Wellbeing, Finland
| | - Antti Markkola
- Department of Radiology, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - Saku T Sinkkonen
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| |
Collapse
|
11
|
Skidmore J, Ramekers D, Colesa DJ, Schvartz-Leyzac KC, Pfingst BE, He S. A Broadly Applicable Method for Characterizing the Slope of the Electrically Evoked Compound Action Potential Amplitude Growth Function. Ear Hear 2022; 43:150-164. [PMID: 34241983 PMCID: PMC8674380 DOI: 10.1097/aud.0000000000001084] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
OBJECTIVES Amplitudes of electrically evoked compound action potentials (eCAPs) as a function of the stimulation level constitute the eCAP amplitude growth function (AGF). The slope of the eCAP AGF (i.e., rate of growth of eCAP amplitude as a function of stimulation level), recorded from subjects with cochlear implants (CIs), has been widely used as an indicator of survival of cochlear nerve fibers. However, substantial variation in the approach used to calculate the slope of the eCAP AGF makes it difficult to compare results across studies. In this study, we developed an improved slope-fitting method by addressing the limitations of previously used approaches and ensuring its application for the estimation of the maximum slopes of the eCAP AGFs recorded in both animal models and human listeners with various etiologies. DESIGN The new eCAP AGF fitting method was designed based on sliding window linear regression. Slopes of the eCAP AGF estimated using this new fitting method were calculated and compared with those estimated using four other fitting methods reported in the literature. These four methods were nonlinear regression with a sigmoid function, linear regression, gradient calculation, and boxcar smoothing. The comparison was based on the fitting results of 72 eCAP AGFs recorded from 18 acutely implanted guinea pigs, 46 eCAP AGFs recorded from 23 chronically implanted guinea pigs, and 2094 eCAP AGFs recorded from 200 human CI users from 4 patient populations. The effect of the choice of input units of the eCAP AGF (linear versus logarithmic) on fitting results was also evaluated. RESULTS The slope of the eCAP AGF was significantly influenced by the slope-fitting method and by the choice of input units. Overall, slopes estimated using all five fitting methods reflected known patterns of neural survival in human patient populations and were significantly correlated with speech perception scores. However, slopes estimated using the newly developed method showed the highest correlation with spiral ganglion neuron density among all five fitting methods for animal models. In addition, this new method could reliably and accurately estimate the slope for 4 human patient populations, while the performance of the other methods was highly influenced by the morphology of the eCAP AGF. CONCLUSIONS The novel slope-fitting method presented in this study addressed the limitations of the other methods reported in the literature and successfully characterized the slope of the eCAP AGF for various animal models and CI patient populations. This method may be useful for researchers in conducting scientific studies and for clinicians in providing clinical care for CI users.
Collapse
Affiliation(s)
- Jeffrey Skidmore
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212, USA
| | - Dyan Ramekers
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Room G.02.531, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
- UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| | - Deborah J. Colesa
- Kresge Hearing Research Institute, Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, 1150 West Medical Center Drive, Ann Arbor, MI 48109-5616, USA
| | - Kara C. Schvartz-Leyzac
- Department of Otolaryngology, Medical University of South Carolina, 135 Rutledge Ave, MSC 550, Charleston, SC 29425, USA
| | - Bryan E. Pfingst
- Kresge Hearing Research Institute, Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, 1150 West Medical Center Drive, Ann Arbor, MI 48109-5616, USA
| | - Shuman He
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212, USA
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205, USA
| |
Collapse
|
12
|
Jahn KN, Arenberg JG, Horn DL. Spectral Resolution Development in Children With Normal Hearing and With Cochlear Implants: A Review of Behavioral Studies. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2022; 65:1646-1658. [PMID: 35201848 PMCID: PMC9499384 DOI: 10.1044/2021_jslhr-21-00307] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 09/09/2021] [Accepted: 12/01/2021] [Indexed: 06/14/2023]
Abstract
PURPOSE This review article provides a theoretical overview of the development of spectral resolution in children with normal hearing (cNH) and in those who use cochlear implants (CIs), with an emphasis on methodological considerations. The aim was to identify key directions for future research on spectral resolution development in children with CIs. METHOD A comprehensive literature review was conducted to summarize and synthesize previously published behavioral research on spectral resolution development in normal and impaired auditory systems. CONCLUSIONS In cNH, performance on spectral resolution tasks continues to improve through the teenage years and is likely driven by gradual maturation of across-channel intensity resolution. A small but growing body of evidence from children with CIs suggests a more complex relationship between spectral resolution development, patient demographics, and the quality of the CI electrode-neuron interface. Future research should aim to distinguish between the effects of patient-specific variables and the underlying physiology on spectral resolution abilities in children of all ages who are hard of hearing and use auditory prostheses.
Collapse
Affiliation(s)
- Kelly N. Jahn
- Department of Speech, Language, and Hearing, School of Behavioral and Brain Sciences, The University of Texas at Dallas, Richardson
- Callier Center for Communication Disorders, The University of Texas at Dallas
| | - Julie G. Arenberg
- Department of Otolaryngology – Head and Neck Surgery, Harvard Medical School, Boston, MA
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston
| | - David L. Horn
- Virginia Merrill Bloedel Hearing Research Center, Department of Otolaryngology – Head and Neck Surgery, University of Washington, Seattle
- Division of Otolaryngology, Seattle Children's Hospital, WA
| |
Collapse
|
13
|
Arjmandi MK, Jahn KN, Arenberg JG. Single-Channel Focused Thresholds Relate to Vowel Identification in Pediatric and Adult Cochlear Implant Listeners. Trends Hear 2022; 26:23312165221095364. [PMID: 35505617 PMCID: PMC9073113 DOI: 10.1177/23312165221095364] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Speech recognition outcomes are highly variable among pediatric and adult cochlear implant (CI) listeners. Although there is some evidence that the quality of the electrode-neuron interface (ENI) contributes to this large variability in auditory perception, its relationship with speech outcomes is not well understood. Single-channel auditory detection thresholds measured in response to focused electrical fields (i.e., focused thresholds) are sensitive to properties of ENI quality, including electrode-neuron distance, intracochlear resistance, and neural health. In the present study, focused thresholds and speech perception abilities were assessed in 15 children and 21 adult CI listeners. Focused thresholds were measured for all active electrodes using a fast sweep procedure. Speech perception performance was evaluated by assessing listeners’ ability to identify vowels presented in /h-vowel-d/ context. Consistent with prior literature, focused thresholds were lower for children than for adults, but vowel identification did not differ significantly across age groups. Higher across-array average focused thresholds, which may indicate a relatively poor ENI quality, were associated with poorer vowel identification scores in both children and adults. Adult CI listeners with longer durations of deafness had higher focused thresholds. Findings from this study demonstrate that poor-quality ENIs may contribute to reduced speech outcomes for pediatric and adult CI listeners. Estimates of ENI quality (e.g., focused thresholds) may assist in developing customized programming interventions that serve to improve the transmission of spectral cues that are important in vowel identification.
Collapse
Affiliation(s)
- Meisam K Arjmandi
- Department of Otolaryngology - Head and Neck Surgery, 1811Harvard Medical School, Boston, MA, USA.,Eaton-Peabody Laboratories, 1866Massachusetts Eye and Ear, Boston, MA, USA.,Audiology Division, 1866Massachusetts Eye and Ear, Boston, MA, USA
| | - Kelly N Jahn
- Department of Otolaryngology - Head and Neck Surgery, 1811Harvard Medical School, Boston, MA, USA.,Eaton-Peabody Laboratories, 1866Massachusetts Eye and Ear, Boston, MA, USA.,Department of Speech, Language, and Hearing, University of Texas at Dallas, Richardson, TX, USA
| | - Julie G Arenberg
- Department of Otolaryngology - Head and Neck Surgery, 1811Harvard Medical School, Boston, MA, USA.,Eaton-Peabody Laboratories, 1866Massachusetts Eye and Ear, Boston, MA, USA.,Audiology Division, 1866Massachusetts Eye and Ear, Boston, MA, USA
| |
Collapse
|
14
|
Abstract
OBJECTIVES This study aimed to determine the effect of advanced age on how effectively a cochlear implant (CI) electrode stimulates the targeted cochlear nerve fibers (i.e., the electrode-neuron interface [ENI]) in postlingually deafened adult CI users. The study tested the hypothesis that the quality of the ENI declined with advanced age. It also tested the hypothesis that the effect of advanced age on the quality of the ENI would be greater in basal regions of the cochlea compared to apical regions. DESIGN Study participants included 40 postlingually deafened adult CI users. The participants were separated into two age groups based on age at testing in accordance with age classification terms used by the World Health Organization and the Medical Literature Analysis and Retrieval System Online bibliographic database. The middle-aged group included 16 participants between the ages of 45 and 64 years and the elderly group included 24 participants older than 65 years. Results were included from one ear for each participant. All participants used Cochlear Nucleus CIs in their test ears. For each participant, electrophysiological measures of the electrically evoked compound action potential (eCAP) were used to measure refractory recovery functions and amplitude growth functions (AGFs) at three to seven electrode sites across the electrode array. The eCAP parameters used in this study included the refractory recovery time estimated based on the eCAP refractory recovery function, the eCAP threshold, the slope of the eCAP AGF, and the negative-peak (i.e., N1) latency. The electrode-specific ENI was evaluated using an optimized combination of the eCAP parameters that represented the responsiveness of cochlear nerve fibers to electrical stimulation delivered by individual electrodes along the electrode array. The quality of the electrode-specific ENI was quantified by the local ENI index, a value between 0 and 100 where 0 and 100 represented the lowest- and the highest-quality ENI across all participants and electrodes in the study dataset, respectively. RESULTS There were no significant age group differences in refractory times, eCAP thresholds, N1 latencies or local ENI indices. Slopes of the eCAP AGF were significantly larger in the middle-aged group compared to the elderly group. There was a significant effect of electrode location on each eCAP parameter, except for N1 latency. In addition, the local ENI index was significantly larger (i.e., better ENI) in the apical region than in the basal and middle regions of the cochlea for both age groups. CONCLUSIONS The model developed in this study can be used to estimate the quality of the ENI at individual electrode locations in CI users. The quality of the ENI is affected by the location of the electrode along the length of the cochlea. The method for estimating the quality of the ENI developed in this study holds promise for identifying electrodes with poor ENIs that could be deactivated from the clinical programming map. The ENI is not strongly affected by advanced age in middle-aged and elderly CI users.
Collapse
|
15
|
Langner F, Arenberg JG, Büchner A, Nogueira W. Assessing the relationship between neural health measures and speech performance with simultaneous electric stimulation in cochlear implant listeners. PLoS One 2021; 16:e0261295. [PMID: 34898654 PMCID: PMC8668108 DOI: 10.1371/journal.pone.0261295] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 11/29/2021] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVES The relationship between electrode-nerve interface (ENI) estimates and inter-subject differences in speech performance with sequential and simultaneous channel stimulation in adult cochlear implant listeners were explored. We investigated the hypothesis that individuals with good ENIs would perform better with simultaneous compared to sequential channel stimulation speech processing strategies than those estimated to have poor ENIs. METHODS Fourteen postlingually deaf implanted cochlear implant users participated in the study. Speech understanding was assessed with a sentence test at signal-to-noise ratios that resulted in 50% performance for each user with the baseline strategy F120 Sequential. Two simultaneous stimulation strategies with either two (Paired) or three sets of virtual channels (Triplet) were tested at the same signal-to-noise ratio. ENI measures were estimated through: (I) voltage spread with electrical field imaging, (II) behavioral detection thresholds with focused stimulation, and (III) slope (IPG slope effect) and 50%-point differences (dB offset effect) of amplitude growth functions from electrically evoked compound action potentials with two interphase gaps. RESULTS A significant effect of strategy on speech understanding performance was found, with Triplets showing a trend towards worse speech understanding performance than sequential stimulation. Focused thresholds correlated positively with the difference required to reach most comfortable level (MCL) between Sequential and Triplet strategies, an indirect measure of channel interaction. A significant offset effect (difference in dB between 50%-point for higher eCAP growth function slopes with two IPGs) was observed. No significant correlation was observed between the slopes for the two IPGs tested. None of the measures used in this study correlated with the differences in speech understanding scores between strategies. CONCLUSIONS The ENI measure based on behavioral focused thresholds could explain some of the difference in MCLs, but none of the ENI measures could explain the decrease in speech understanding with increasing pairs of simultaneously stimulated electrodes in processing strategies.
Collapse
Affiliation(s)
- Florian Langner
- Department of Otorhinolaryngology, Hannover Medical School and Cluster of Excellence Hearing4all, Hanover, Germany
| | - Julie G. Arenberg
- Department of Otolaryngology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, United States of America
| | - Andreas Büchner
- Department of Otorhinolaryngology, Hannover Medical School and Cluster of Excellence Hearing4all, Hanover, Germany
| | - Waldo Nogueira
- Department of Otorhinolaryngology, Hannover Medical School and Cluster of Excellence Hearing4all, Hanover, Germany
| |
Collapse
|
16
|
Johnson KC, Xie Z, Shader MJ, Mayo PG, Goupell MJ. Effect of Chronological Age on Pulse Rate Discrimination in Adult Cochlear-Implant Users. Trends Hear 2021; 25:23312165211007367. [PMID: 34028313 PMCID: PMC8150454 DOI: 10.1177/23312165211007367] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Cochlear-implant (CI) users rely heavily on temporal envelope cues to understand speech. Temporal processing abilities may decline with advancing age in adult CI users. This study investigated the effect of age on the ability to discriminate changes in pulse rate. Twenty CI users aged 23 to 80 years participated in a rate discrimination task. They attempted to discriminate a 35% rate increase from baseline rates of 100, 200, 300, 400, or 500 pulses per second. The stimuli were electrical pulse trains delivered to a single electrode via direct stimulation to an apical (Electrode 20), a middle (Electrode 12), or a basal location (Electrode 4). Electrically evoked compound action potential amplitude growth functions were recorded at each of those electrodes as an estimate of peripheral neural survival. Results showed that temporal pulse rate discrimination performance declined with advancing age at higher stimulation rates (e.g., 500 pulses per second) when compared with lower rates. The age-related changes in temporal pulse rate discrimination at higher stimulation rates persisted after statistical analysis to account for the estimated peripheral contributions from electrically evoked compound action potential amplitude growth functions. These results indicate the potential contributions of central factors to the limitations in temporal pulse rate discrimination ability associated with aging in CI users.
Collapse
Affiliation(s)
- Kelly C Johnson
- Department of Hearing and Speech Sciences, University of Maryland, College Park, United States
| | - Zilong Xie
- Department of Hearing and Speech, University of Kansas Medical Center, Kansas City, United States
| | - Maureen J Shader
- Department of Hearing and Speech Sciences, University of Maryland, College Park, United States.,Bionics Institute, Melbourne, Australia.,Department of Medical Bionics, The University of Melbourne, Melbourne, Australia
| | - Paul G Mayo
- Department of Hearing and Speech Sciences, University of Maryland, College Park, United States
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, United States
| |
Collapse
|
17
|
Bernhard N, Gauger U, Romo Ventura E, Uecker FC, Olze H, Knopke S, Hänsel T, Coordes A. Duration of deafness impacts auditory performance after cochlear implantation: A meta-analysis. Laryngoscope Investig Otolaryngol 2021; 6:291-301. [PMID: 33869761 PMCID: PMC8035957 DOI: 10.1002/lio2.528] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/14/2021] [Accepted: 01/15/2021] [Indexed: 01/04/2023] Open
Abstract
OBJECTIVE Hearing loss is a highly disabling condition. Cochlear implantation is an established remedy if conventional hearing aids have failed to alleviate the level of disability. Unfortunately, cochlear implant (CI) performance varies dramatically. This study aims to examine the effects of duration of deafness (DoD) prior to cochlear implantation and the postoperative duration of implant experience with resulting hearing performance in postlingually deaf patients. METHODS A systematic literature review and two meta-analyses were conducted using the search terms cochlear implant AND duration deafness. Included studies evaluate the correlation between the DoD and auditory performance after cochlear implantation using monosyllabic and sentence tests. Correlation coefficients were determined using Pearson's correlation and Spearman rho. RESULTS A total of 36 studies were identified and included data on cochlear implantations following postlingual deafness and postoperative speech testing of hearing outcomes for 1802 patients. The mean age ranged from 44 to 68 years with a DoD of 0.1 to 77 years. Cochlear implant use varied from 3 months to 14 years of age. Speech perception, which was assessed by sentence and monosyllabic word perception, was negatively correlated with DoD. Subgroup analyses revealed worse outcomes for longer DoD and shorter postoperative follow-up. CONCLUSION DoD is one of the most important factors to predict speech perception after cochlear implantation in postlingually deaf patients. The meta-analyses revealed a negative correlation between length of auditory deprivation and postoperative sentence and monosyllabic speech perception. Longer DoD seems to lead to worse CI performance, whereas more experience with CI mitigates the effect.
Collapse
Affiliation(s)
- Nikolai Bernhard
- Department of Otorhinolaryngology, Head and Neck SurgeryCharité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt‐Universität zu Berlin, and Berlin Institute of HealthBerlinGermany
| | | | | | - Florian C. Uecker
- Department of Otorhinolaryngology, Head and Neck SurgeryCharité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt‐Universität zu Berlin, and Berlin Institute of HealthBerlinGermany
| | - Heidi Olze
- Department of Otorhinolaryngology, Head and Neck SurgeryCharité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt‐Universität zu Berlin, and Berlin Institute of HealthBerlinGermany
| | - Steffen Knopke
- Department of Otorhinolaryngology, Head and Neck SurgeryCharité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt‐Universität zu Berlin, and Berlin Institute of HealthBerlinGermany
| | - Toni Hänsel
- Department of Otorhinolaryngology, Head and Neck SurgeryCharité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt‐Universität zu Berlin, and Berlin Institute of HealthBerlinGermany
| | - Annekatrin Coordes
- Department of Otorhinolaryngology, Head and Neck SurgeryCharité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt‐Universität zu Berlin, and Berlin Institute of HealthBerlinGermany
| |
Collapse
|
18
|
Gärtner L, Klötzer K, Lenarz T, Scheper V. Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients-Identification of Predictors for the Neuronal Health Status. Life (Basel) 2021; 11:life11030203. [PMID: 33807687 PMCID: PMC7999542 DOI: 10.3390/life11030203] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 02/26/2021] [Accepted: 03/01/2021] [Indexed: 01/04/2023] Open
Abstract
Cochlear implants (CI) are the treatment of choice in profoundly deaf patients. Measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the function of the spiral ganglion neurons (SGN), which are the target cells of the CI stimulation. ECAP measurement is only possible after electrode insertion. No information about the neuronal health status is available before cochlear implantation. We investigated possible correlations between the ECAP amplitude growth function (AGF) slope and anamnestic parameters to identify possible predictors for SGN health status and therefore for CI outcome. The study included patients being implanted with various electrode array lengths. Correlation analysis was performed for the mean AGF slope of the whole array, for separate electrodes as well as for grouped electrodes of the apical, medial, and basal region, with duration of deafness, age at implantation, residual hearing (grouped for electrode length), and etiology. The mean ECAP AGF slopes decreased from apical to basal. They were not correlated to the length of the electrode array or any etiology. For the mean of the full array or when grouped for the apical, middle, and basal part, the ECAP AGF slope was negatively correlated to the duration of hearing loss and the age at implantation. Since a significant negative correlation of the ECAP AGF slope and age at cochlear implantation and duration of deafness was observed, this study supports the statement that early implantation of a CI is recommended for sensorineural hearing loss. Additional factors such as the cochlear coverage and insertion angle influence the ECAP AGF slope and performance of the patient and should be included in future multifactorial analysis to study predictive parameters for the CI outcome.
Collapse
Affiliation(s)
- Lutz Gärtner
- Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany; (L.G.); (K.K.); (T.L.)
| | - Katharina Klötzer
- Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany; (L.G.); (K.K.); (T.L.)
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany; (L.G.); (K.K.); (T.L.)
- Cluster of Excellence “Hearing4All”, 30625 Hannover, Germany
| | - Verena Scheper
- Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany; (L.G.); (K.K.); (T.L.)
- Cluster of Excellence “Hearing4All”, 30625 Hannover, Germany
- Correspondence: ; Tel.: +49-511-532-4369
| |
Collapse
|
19
|
Jahn KN, DeVries L, Arenberg JG. Recovery from forward masking in cochlear implant listeners: Effects of age and the electrode-neuron interface. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:1633. [PMID: 33765782 PMCID: PMC8267874 DOI: 10.1121/10.0003623] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 02/12/2021] [Accepted: 02/12/2021] [Indexed: 06/12/2023]
Abstract
Older adults exhibit deficits in auditory temporal processing relative to younger listeners. These age-related temporal processing difficulties may be further exacerbated in older adults with cochlear implant (CIs) when CI electrodes poorly interface with their target auditory neurons. The aim of this study was to evaluate the potential interaction between chronological age and the estimated quality of the electrode-neuron interface (ENI) on psychophysical forward masking recovery, a measure that reflects single-channel temporal processing abilities. Fourteen CI listeners (age 15 to 88 years) with Advanced Bionics devices participated. Forward masking recovery was assessed on two channels in each ear (i.e., the channels with the lowest and highest signal detection thresholds). Results indicated that the rate of forward masking recovery declined with advancing age, and that the effect of age was more pronounced on channels estimated to interface poorly with the auditory nerve. These findings indicate that the quality of the ENI can influence the time course of forward masking recovery for older CI listeners. Channel-to-channel variability in the ENI likely interacts with central temporal processing deficits secondary to auditory aging, warranting further study of programming and rehabilitative approaches tailored to older listeners.
Collapse
Affiliation(s)
- Kelly N Jahn
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington 98105, USA
| | - Lindsay DeVries
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Julie G Arenberg
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington 98105, USA
| |
Collapse
|