1
|
Seebens Y, Metzeld D, Helbig S, Schäfer K. Fitting parameters in children with cochlear implants and severe additional disabilities. Eur Arch Otorhinolaryngol 2025; 282:63-77. [PMID: 39136774 DOI: 10.1007/s00405-024-08890-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Accepted: 08/01/2024] [Indexed: 01/18/2025]
Abstract
PURPOSE The aim of this study was to investigate whether the fitting data of children with Cochlear implants (CI) and severe additional disabilities (CAD) differ compared to children with CI but without additional disabilities (CnonAD). METHODS In this retrospective analysis, 76 CI cases (fitted ears) from CAD were included and matched with 76 cases from CnonAD. The subjective set values, such as pulse width (PW), threshold (T) and most comfortable (MC) levels were recorded. Additionally, the response threshold values by means of aided soundfield threshold (AST), the values of the intracochlear electrode impedances, the eCAP thresholds and the daily wearing time by using data logging were recorded and analysed. RESULTS The T and MC levels for the Medel implants were significantly lower in the sample than in the control group. A similar trend was evident for Cochlear® implants. The sample showed a positive correlation between the eCAP thresholds and the T level and MC level in case of the Cochlear implants. The CAD group showed a significantly higher aided soundfield threshold. In contrast to the CnonAD (0%), there was a total of 18% in the CAD with a reduced daily wearing time. When these were excluded, eCAP thresholds were significantly higher in the CAD group. In addition, there was a trend for eCAP thresholds to be higher if the contralateral ear was not also fitted with a CI. CONCLUSIONS The significantly higher eCAPs in CAD may be explained by different neural survival but also by different fittings and MC levels. The audiuologist's subjectivity must be considered as a potential bias but also as potentially valuable input variable contributing to the variance in the fitting parameters and outcomes. Better fitting of T and MC levels focusing on behavioural and developmental responses may lead to a longer wearing time. To support the audiologist and the fitting process, it is necessary to interpret the response thresholds in the aided soundfield threshold against the background of the medical diagnosis and observations from everyday life should be considered. To ensure optimal development of CAD children according to their individual abilities, a multi-professional, family-centred intervention programme including videoanalyses should be implemented at an early stage, ideally from the decision process for a cochlear implant.
Collapse
Affiliation(s)
- Yvonne Seebens
- Hör- und Sprachförderung Rhein-Main gGmbH, Cochlear Implant Centre Rhein-Main, Grüner Weg 9, 61169, Friedberg, Germany.
- Faculty of Human Sciences, Department of Special Education and Rehabilitation, University of Cologne, Klosterstr. 79B Brieffach: 12, 50931, Cologne, Germany.
| | - Dennis Metzeld
- Hör- und Sprachförderung Rhein-Main gGmbH, Cochlear Implant Centre Rhein-Main, Grüner Weg 9, 61169, Friedberg, Germany
| | - Silke Helbig
- Hör- und Sprachförderung Rhein-Main gGmbH, Cochlear Implant Centre Rhein-Main, Grüner Weg 9, 61169, Friedberg, Germany
- ENT-Department, Clinic for Otorhinolaryngology, Goethe University Frankfurt, University Hospital, Theodor-Stern-Kai 7, 60596, Frankfurt, Germany
| | - Karolin Schäfer
- Faculty of Human Sciences, Department of Special Education and Rehabilitation, University of Cologne, Klosterstr. 79B Brieffach: 12, 50931, Cologne, Germany
| |
Collapse
|
2
|
Berg KA, Chen C, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Effects of the Number of Channels and Channel Stimulation Rate on Speech Recognition and Sound Quality Using Precurved Electrode Arrays. Am J Audiol 2023; 32:403-416. [PMID: 37249492 PMCID: PMC10468116 DOI: 10.1044/2023_aja-22-00032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 06/16/2022] [Accepted: 02/05/2023] [Indexed: 05/31/2023] Open
Abstract
PURPOSE This study investigated the relationship between the number of active electrodes, channel stimulation rate, and their interaction on speech recognition and sound quality measures while controlling for electrode placement. Cochlear implant (CI) recipients with precurved electrode arrays placed entirely within scala tympani and closer to the modiolus were hypothesized to be able to utilize more channels and possibly higher stimulation rates to achieve better speech recognition performance and sound quality ratings than recipients in previous studies. METHOD Participants included seven postlingually deafened adult CI recipients with Advanced Bionics Mid-Scala electrode arrays confirmed to be entirely within scala tympani using postoperative computerized tomography. Twelve conditions were tested using four, eight, 12, and 16 electrodes and channel stimulation rates of 600 pulse per second (pps), 1,200 pps, and each participant's maximum allowable rate (1,245-4,800 pps). Measures of speech recognition and sound quality were acutely assessed. RESULTS For the effect of channels, results showed no significant improvements beyond eight channels for all measures. For the effect of channel stimulation rate, results showed no significant improvements with higher rates, suggesting that 600 pps was sufficient for maximum speech recognition performance and sound quality ratings. However, across all conditions, there was a significant relationship between mean electrode-to-modiolus distance and all measures, suggesting that a lower mean electrode-to-modiolus distance was correlated with higher speech recognition scores and sound quality ratings. CONCLUSION These findings suggest that even well-placed precurved electrode array recipients may not be able to take advantage of more than eight channels or higher channel stimulation rates (> 600 pps), but that closer electrode array placement to the modiolus correlates with better outcomes for these recipients.
Collapse
Affiliation(s)
- Katelyn A. Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| | - Chen Chen
- Research and Technology, Advanced Bionics, LLC, Valencia, CA
| | - Jack H. Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN
| | - Benoit M. Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN
| | - Robert T. Dwyer
- Research and Technology, Advanced Bionics, LLC, Valencia, CA
| | - Robert F. Labadie
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston
| | - René H. Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| |
Collapse
|
3
|
Obando-Leitón M, Dietze A, Castañeda González CM, Saeedi A, Karg S, Hemmert W. On the Effect of High Stimulation Rates on Temporal Loudness Integration in Cochlear Implant Users. Trends Hear 2023; 27:23312165231207229. [PMID: 37936420 PMCID: PMC10631326 DOI: 10.1177/23312165231207229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 08/18/2023] [Accepted: 09/26/2023] [Indexed: 11/09/2023] Open
Abstract
Long stimuli have lower detection thresholds or are perceived louder than short stimuli with the same intensity, an effect known as temporal loudness integration (TLI). In electric hearing, TLI for pulse trains with a fixed rate but varying number of pulses, i.e. stimulus duration, has mainly been investigated at clinically used stimulation rates. To study the effect of an overall effective stimulation rate at 100% channel crosstalk, we investigated TLI with (a) a clinically used single-channel stimulation rate of 1,500 pps and (b) a high stimulation rate of 18,000 pps, both for an apical and a basal electrode. Thresholds (THR), a line of equal loudness (BAL), and maximum acceptable levels (MALs) were measured in 10 MED-EL cochlear implant users. Stimulus durations varied from a single pulse to 300 ms long pulse trains. At 18,000 pps, the dynamic range (DR) increased by 7.36 ± 3.16 dB for the 300 ms pulse train. Amplitudes at THR, BAL, and MAL decreased monotonically with increasing stimulus duration. The decline was fitted with high accuracy with a power law function (R 2 = 0.94 ± 0.06 ). Threshold slopes were - 1.05 ± 0.36 and - 1.66 ± 0.30 dB per doubling of duration for the low and high rate, respectively, and were shallower than for acoustic hearing. The electrode location did not affect the amplitudes or slopes of the TLI curves. THR, BAL, and MAL were always lower for the higher rate and the DR was larger at the higher rate at all measured durations.
Collapse
Affiliation(s)
- Miguel Obando-Leitón
- Bio-Inspired Information Processing, Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
- TUM School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
| | - Anna Dietze
- Bio-Inspired Information Processing, Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
- TUM School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
- Graduate School of Systemic Neurosciences, Ludwig-Maximilians Universität München, Planegg, Germany
| | - Carmen M. Castañeda González
- Bio-Inspired Information Processing, Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
- TUM School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
| | - Ali Saeedi
- Bio-Inspired Information Processing, Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
- TUM School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
| | - Sonja Karg
- Bio-Inspired Information Processing, Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
- TUM School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
| | - Werner Hemmert
- Bio-Inspired Information Processing, Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
- TUM School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
- Munich Institute of Robotics and Machine Intelligence, Technical University of Munich, Munich, Germany
| |
Collapse
|
4
|
Lanthaler D, Griessner A, Steixner V, Hubner PP, Ranieri M, Cavuscens S, Boutabla A, Zierhofer CM, Perez Fornos A. Speech Perception With Novel Stimulation Strategies for CombinedCochleo-Vestibular Systems. IEEE Trans Neural Syst Rehabil Eng 2021; 29:1644-1650. [PMID: 34398757 DOI: 10.1109/tnsre.2021.3105271] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Cochlear implants are very well established in the rehabilitation of hearing loss and are regarded as the most successful neuroprostheses to date. While a lot of progress has also been made in the neighboring field of specific vestibular implants, some diseases affect the entire inner ear, leading to both hearing and vestibular hypo- or dysfunction. The proximity of the cochlear and vestibular organs suggests a single combined implant as a means to alleviate the associated impairments. While both organs can be stimulated in a similar way with electric pulses applied through implanted electrodes, the typical phase durations needed in the vestibular system seem to be substantially larger than those typically needed in the cochlear system. Therefore, when using sequential stimulation in a combined implant, the pulse stream to the cochlea is interrupted by comparatively large gaps in which vestibular stimulation can occur. We investigate the impact of these gaps in the auditory stream on speech perception. Specifically, we compare a number of stimulation strategies with different gap lengths and distributions and evaluate whether it is feasible to use them without having a noticeable decline in perception and quality of speech. This is a prerequisite for any practicable stimulation strategy of a combined system and can be investigated even in recipients of a normal cochlear implant. Our results show that there is no significant deterioration in speech perception for the different strategies examined in this paper, leaving the strategies as viable candidates for prospective combined cochleo-vestibular implants.
Collapse
|
5
|
He S, Xu L, Skidmore J, Chao X, Riggs WJ, Wang R, Vaughan C, Luo J, Shannon M, Warner C. Effect of Increasing Pulse Phase Duration on Neural Responsiveness of the Electrically Stimulated Cochlear Nerve. Ear Hear 2021; 41:1606-1618. [PMID: 33136636 PMCID: PMC7529657 DOI: 10.1097/aud.0000000000000876] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The aim of this study is to (1) investigate the effects of increasing the pulse phase duration (PPD) on the neural response of the electrically stimulated cochlear nerve (CN) in children with CN deficiency (CND) and (2) compare the results from the CND population to those measured in children with normal-sized CNs. DESIGN Study participants included 30 children with CND and 30 children with normal-sized CNs. All participants used a Cochlear Nucleus device in the test ear. For each subject, electrically evoked compound action potential (eCAP) input/output (I/O) functions evoked by single biphasic pulses with different PPDs were recorded at three electrode locations across the electrode array. PPD durations tested in this study included 50, 62, 75, and 88 μsec/phase. For each electrode tested for each study participant, the amount of electrical charge corresponding to the maximum comfortable level measured for the 88 μsec PPD was used as the upper limit of stimulation. The eCAP amplitude measured at the highest electrical charge level, the eCAP threshold (i.e., the lowest level that evoked an eCAP), and the slope of the eCAP I/O function were measured. Generalized linear mixed effect models with study group, electrode location, and PPD as the fixed effects and subject as the random effect were used to compare these dependent variables measured at different electrode locations and PPDs between children with CND and children with normal-sized CNs. RESULTS Children with CND had smaller eCAP amplitudes, higher eCAP thresholds, and smaller slopes of the eCAP I/O function than children with normal-sized CNs. Children with CND who had fewer electrodes with a measurable eCAP showed smaller eCAP amplitudes and flatter eCAP I/O functions than children with CND who had more electrodes with eCAPs. Increasing the PPD did not show a statistically significant effect on any of these three eCAP parameters in the two subject groups tested in this study. CONCLUSIONS For the same amount of electrical charge, increasing the PPD from 50 to 88 μsec for a biphasic pulse with a 7 μsec interphase gap did not significantly affect CN responsiveness to electrical stimulation in human cochlear implant users. Further studies with different electrical pulse configurations are warranted to determine whether evaluating the eCAP sensitivity to changes in the PPD can be used as a testing paradigm to estimate neural survival of the CN for individual cochlear implant users.
Collapse
Affiliation(s)
- Shuman He
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Lei Xu
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Jeffrey Skidmore
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Xiuhua Chao
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - William J. Riggs
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Ruijie Wang
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Chloe Vaughan
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Jianfen Luo
- Department of Auditory Implantation, Shandong Provincial ENT Hospital Affiliated to Shandong University, Duanxing W. Rd, Huaiyin, Jinan, Shandong Province, P.R. China 250022
| | - Michelle Shannon
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Cynthia Warner
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| |
Collapse
|
6
|
Neural Tissue Degeneration in Rosenthal's Canal and Its Impact on Electrical Stimulation of the Auditory Nerve by Cochlear Implants: An Image-Based Modeling Study. Int J Mol Sci 2020; 21:ijms21228511. [PMID: 33198187 PMCID: PMC7697226 DOI: 10.3390/ijms21228511] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 11/06/2020] [Accepted: 11/09/2020] [Indexed: 11/24/2022] Open
Abstract
Sensorineural deafness is caused by the loss of peripheral neural input to the auditory nerve, which may result from peripheral neural degeneration and/or a loss of inner hair cells. Provided spiral ganglion cells and their central processes are patent, cochlear implants can be used to electrically stimulate the auditory nerve to facilitate hearing in the deaf or severely hard-of-hearing. Neural degeneration is a crucial impediment to the functional success of a cochlear implant. The present, first-of-its-kind two-dimensional finite-element model investigates how the depletion of neural tissues might alter the electrically induced transmembrane potential of spiral ganglion neurons. The study suggests that even as little as 10% of neural tissue degeneration could lead to a disproportionate change in the stimulation profile of the auditory nerve. This result implies that apart from encapsulation layer formation around the cochlear implant electrode, tissue degeneration could also be an essential reason for the apparent inconsistencies in the functionality of cochlear implants.
Collapse
|
7
|
|
8
|
Abstract
OBJECTIVES In an attempt to improve spectral resolution and speech intelligibility, several current focusing methods have been proposed to increase spatial selectivity by decreasing intracochlear current spread. For example, tripolar stimulation administers current to a central electrode and uses the two flanking electrodes as the return pathway, creating a narrower intracochlear electrical field and hence increases spectral resolution when compared with monopolar (MP) stimulation. However, more current is required, and in some patients, specifically the ones with high electrode impedances, full loudness growth cannot be supported because of compliance limits. The present study describes and analyses a new loudness encoding approach that uses tripolar stimulation near threshold and gradually broadens the excitation (by decreasing compensation coefficient σ) to increase loudness without the need to increase overall current. It is hypothesized that this dynamic current focusing (DCF) strategy increases spatial selectivity, especially at lower loudness levels, while maintaining maximum selectivity at higher loudness levels, without reaching compliance limits. DESIGN Eleven adult cochlear implant recipients with postlingual hearing loss, with at least 9 months of experience with their HiRes90K implant, were selected to participate in this study. Baseline performance regarding speech intelligibility in noise (Dutch matrix sentence test), spectral ripple discrimination at 45 and 65 dB, and temporal modulation detection thresholds were assessed using their own clinical program, fitted on a Harmony processor. Subsequently, the DCF strategy was fitted on a research Harmony processor. Threshold levels were determined with σ = 0.8, which means 80% of current is returned to the flanking electrodes and the remaining 20% to the extracochlear ground electrode. Instead of increasing overall pulse magnitude, σ was decreased to determine most comfortable loudness. After 2 to 3 hr of adaptation to the research strategy, the same psychophysical measures were taken. RESULTS At 45 dB, average spectral ripple scores improved significantly from 2.4 ripples per octave with their clinical program to 3.74 ripples per octave with the DCF strategy (p = 0.016). Eight out of 11 participants had an improved spectral resolution at 65 dB. Nevertheless, no significant difference between DCF and MP was observed at higher presentation levels. Both speech-in-noise and temporal modulation detection thresholds were equal for MP and DCF strategies. Subjectively, 2 participants preferred the DCF strategy over their own clinical program, 2 preferred their own strategy, while the majority of the participants had no preference. Battery life was decreased and ranged from 1.5 to 4 hr. CONCLUSIONS The DCF strategy gives better spectral resolution, at lower loudness levels, but equal performance on speech tests. These outcomes warrant for a longer adaptation period to study long-term outcomes and evaluate if the outcomes in the ripple tests transfer to the speech scores. Further research, for example, with respect to fitting rules and reduction of power consumption, is necessary to make the DCF strategy suitable for routine clinical application.
Collapse
|
9
|
Nunn TB, Jiang D, Green T, Boyle PJ, Vickers DA. A systematic review of the impact of adjusting input dynamic range (IDR), electrical threshold (T) level and rate of stimulation on speech perception ability in cochlear implant users. Int J Audiol 2019; 58:317-325. [DOI: 10.1080/14992027.2018.1564844] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Terry B. Nunn
- University College London Ear Institute, London, UK
- Guy’s and St Thomas’ NHS Trust, Hearing Implant Centre, London, UK
| | - Dan Jiang
- Guy’s and St Thomas’ NHS Trust, Hearing Implant Centre, London, UK
| | - Tim Green
- Department of Speech Hearing and Phonetic Sciences, University College London, London, UK
| | - Patrick J. Boyle
- Advanced Bionics GmbH, European Research Centre, Hannover, Germany
| | - Deborah A. Vickers
- Department of Speech Hearing and Phonetic Sciences, University College London, London, UK
| |
Collapse
|
10
|
Wagner L, Maurits N, Maat B, Baskent D, Wagner AE. The Cochlear Implant EEG Artifact Recorded From an Artificial Brain for Complex Acoustic Stimuli. IEEE Trans Neural Syst Rehabil Eng 2019; 26:392-399. [PMID: 29432110 DOI: 10.1109/tnsre.2018.2789780] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Electroencephalographic (EEG) recordings provide objective estimates of listeners' cortical processing of sounds and of the status of their speech perception system. For profoundly deaf listeners with cochlear implants (CIs), the applications of EEG are limited because the device adds electric artifacts to the recordings. This restricts the possibilities for the neural-based metrics of speech processing by CI users, for instance to gauge cortical reorganization due to individual's hearing loss history. This paper describes the characteristics of the CI artifact as recorded with an artificial head substitute, and reports how the artifact is affected by the properties of the acoustical input signal versus the settings of the device. METHODS We created a brain substitute using agar that simulates the brain's conductivity, placed it in a human skull, and performed EEG recordings with CIs from three different manufacturers. As stimuli, we used simple and complex non-speech stimuli, as well as naturally produced continuous speech. We examined the effect of manipulating device settings in both controlled experimental CI configurations and real clinical maps. RESULTS An increase in the magnitude of the stimulation current through the device settings increases also the magnitude of the artifact. The artifact recorded to speech is smaller in magnitude than for non-speech stimuli due to signal-inherent amplitude modulations. CONCLUSION The CI EEG artifact for speech appears more difficult to detect than for simple stimuli. Since the artifact differs across CI users, due to their individual clinical maps, the method presented enables insight into the individual manifestations of the artifact.
Collapse
|
11
|
Loeb GE. Neural Prosthetics:A Review of Empirical vs. Systems Engineering Strategies. Appl Bionics Biomech 2018; 2018:1435030. [PMID: 30532801 PMCID: PMC6247642 DOI: 10.1155/2018/1435030] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Revised: 06/28/2018] [Accepted: 08/05/2018] [Indexed: 12/21/2022] Open
Abstract
Implantable electrical interfaces with the nervous system were first enabled by cardiac pacemaker technology over 50 years ago and have since diverged into almost all of the physiological functions controlled by the nervous system. There have been a few major clinical and commercial successes, many contentious claims, and some outright failures. These tend to be reviewed within each clinical subspecialty, obscuring the many commonalities of neural control, biophysics, interface materials, electronic technologies, and medical device regulation that they share. This review cites a selection of foundational and recent journal articles and reviews for all major applications of neural prosthetic interfaces in clinical use, trials, or development. The hard-won knowledge and experience across all of these fields can now be amalgamated and distilled into more systematic processes for development of clinical products instead of the often empirical (trial and error) approaches to date. These include a frank assessment of a specific clinical problem, the state of its underlying science, the identification of feasible targets, the availability of suitable technologies, and the path to regulatory and reimbursement approval. Increasing commercial interest and investment facilitates this systematic approach, but it also motivates projects and products whose claims are dubious.
Collapse
Affiliation(s)
- Gerald E. Loeb
- Professor of Biomedical Engineering, University of Southern California, 1042 Downey Way (DRB-B11) Los Angeles, CA 90089, USA
| |
Collapse
|
12
|
Adenis V, Gourévitch B, Mamelle E, Recugnat M, Stahl P, Gnansia D, Nguyen Y, Edeline JM. ECAP growth function to increasing pulse amplitude or pulse duration demonstrates large inter-animal variability that is reflected in auditory cortex of the guinea pig. PLoS One 2018; 13:e0201771. [PMID: 30071005 PMCID: PMC6072127 DOI: 10.1371/journal.pone.0201771] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2018] [Accepted: 07/21/2018] [Indexed: 12/20/2022] Open
Abstract
Despite remarkable advances made to ameliorate how cochlear implants process the acoustic environment, many improvements can still be made. One of most fundamental questions concerns a strategy to simulate an increase in sound intensity. Psychoacoustic studies indicated that acting on either the current, or the duration of the stimulating pulses leads to perception of changes in how loud the sound is. The present study compared the growth function of electrically evoked Compound Action Potentials (eCAP) of the 8th nerve using these two strategies to increase electrical charges (and potentially to increase the sound intensity). Both with chronically (experiment 1) or acutely (experiment 2) implanted guinea pigs, only a few differences were observed between the mean eCAP amplitude growth functions obtained with the two strategies. However, both in chronic and acute experiments, many animals showed larger increases of eCAP amplitude with current increase, whereas some animals showed larger of eCAP amplitude with duration increase, and other animals show no difference between either approaches. This indicates that the parameters allowing the largest increase in eCAP amplitude considerably differ between subjects. In addition, there was a significant correlation between the strength of neuronal firing rate in auditory cortex and the effect of these two strategies on the eCAP amplitude. This suggests that pre-selecting only one strategy for recruiting auditory nerve fibers in a given subject might not be appropriate for all human subjects.
Collapse
Affiliation(s)
- Victor Adenis
- Paris-Saclay Institute of Neurosciences (Neuro-PSI) Université Paris-Sud, Orsay, France
- CNRS UMR 9197, Orsay, France
- Université Paris-Saclay, Orsay, France
| | - Boris Gourévitch
- Paris-Saclay Institute of Neurosciences (Neuro-PSI) Université Paris-Sud, Orsay, France
- CNRS UMR 9197, Orsay, France
- Université Paris-Saclay, Orsay, France
| | | | | | | | | | - Yann Nguyen
- INSERM UMR-S-1159, Paris, France
- Université Paris-VI, Paris, France
| | - Jean-Marc Edeline
- Paris-Saclay Institute of Neurosciences (Neuro-PSI) Université Paris-Sud, Orsay, France
- CNRS UMR 9197, Orsay, France
- Université Paris-Saclay, Orsay, France
- * E-mail:
| |
Collapse
|
13
|
Todd AE, Landsberger DM. The effect of polarity order and electrode-activation order on loudness in cochlear implant users. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:EL112. [PMID: 30180697 PMCID: PMC6086690 DOI: 10.1121/1.5049701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Revised: 07/13/2018] [Accepted: 07/24/2018] [Indexed: 06/08/2023]
Abstract
This study examined the interaction between polarity and electrode-activation order on loudness in cochlear implant users. Pulses were presented with the polarity of the leading phase alternating or constant across channels. Electrode-activation order was either consecutive or staggered. Staggered electrode-activation orders required less current for equal loudness than consecutive orders with constant polarity. Consecutive electrode-activation orders required less current than staggered orders with alternating polarity. The results support the hypothesis that crosstalk between channels can interfere with or facilitate neuronal activation depending on polarity.
Collapse
Affiliation(s)
- Ann E Todd
- Department of Otolaryngology, New York University School of Medicine, 550 First Avenue, NBV 5E5, New York, New York 10016, USA ,
| | - David M Landsberger
- Department of Otolaryngology, New York University School of Medicine, 550 First Avenue, NBV 5E5, New York, New York 10016, USA ,
| |
Collapse
|
14
|
Langner F, Saoji AA, Büchner A, Nogueira W. Adding simultaneous stimulating channels to reduce power consumption in cochlear implants. Hear Res 2017; 345:96-107. [PMID: 28104408 DOI: 10.1016/j.heares.2017.01.010] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Revised: 01/10/2017] [Accepted: 01/12/2017] [Indexed: 11/30/2022]
|
15
|
Reducing interaction in simultaneous paired stimulation with CI. PLoS One 2017; 12:e0171071. [PMID: 28182685 PMCID: PMC5300223 DOI: 10.1371/journal.pone.0171071] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Accepted: 01/17/2017] [Indexed: 12/05/2022] Open
Abstract
In this study simultaneous paired stimulation of electrodes in cochlear implants is investigated by psychophysical experiments in 8 post-lingually deaf subjects (and one extra subject who only participated in part of the experiments). Simultaneous and sequential monopolar stimulation modes are used as references and are compared to channel interaction compensation, partial tripolar stimulation and a novel sequential stimulation strategy named phased array compensation. Psychophysical experiments are performed to investigate both the loudness integration during paired stimulation at the main electrodes as well as the interaction with the electrode contact located halfway between the stimulating pair. The study shows that simultaneous monopolar stimulation has more loudness integration on the main electrodes and more interaction in between the electrodes than sequential stimulation. Channel interaction compensation works to reduce the loudness integration at the main electrodes, but does not reduce the interaction in between the electrodes caused by paired stimulation. Partial tripolar stimulation uses much more current to reach the needed loudness, but shows the same interaction in between the electrodes as sequential monopolar stimulation. In phased array compensation we have used the individual impedance matrix of each subject to calculate the current needed on each electrode to exactly match the stimulation voltage along the array to that of sequential stimulation. The results show that the interaction in between the electrodes is the same as monopolar stimulation. The strategy uses less current than partial tripolar stimulation, but more than monopolar stimulation. In conclusion, the paper shows that paired stimulation is possible if the interaction is compensated.
Collapse
|
16
|
Zarei E, Sadjedi H. A new approach for speech synthesis in cochlear implant systems based on electrophysiological factors. Technol Health Care 2016; 25:221-235. [PMID: 27689564 DOI: 10.3233/thc-161265] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Speech synthesis models have been considered as viable tools for performance evaluation of cochlear stimulation algorithms, due to the difficulties of clinical tests. OBJECTIVE The present study has developed a tool that can be used before any audio signal reconstruction algorithm, which shows more conformity with the electrophysiological parameters of the patient in evaluation of the cochlear implant stimulation algorithms. METHODS In this method, excitable nerve fiber characteristics such as stimulation threshold and effective refractory period have been considered in the signal pre-reconstruction process. This algorithm subsumes the user's biological parameters (e.g., the manner of distribution of the remaining intact nerve fibers) as well as the stimulation signal parameters (e.g., stimulation rate, pulse width, amplitude of stimulation, the distance between stimulation electrode and fibers) in the signal pre-reconstruction. RESULTS Effect of changes in these parameters can be observed by the number of excited fibers, which is directly related to the signal intensity and pitch frequency perceived by the user. The obtained results from simulations are in accordance with previous clinical findings. Also, the ability of the proposed tool can be seen by the correspondence between the results obtained from the proposed model and the amplitude growth functions of the cochlear implant users. CONCLUSIONS This paper has introduced a tool for signal reconstruction from electrical stimulation so that a more comprehensive criterion for examination of the stimulating algorithms in cochlear implant can be achieved.
Collapse
Affiliation(s)
- Elham Zarei
- Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Hamed Sadjedi
- Engineering Faculty, Shahed University, Tehran, Iran
| |
Collapse
|
17
|
Cosentino S, Deeks JM, Carlyon RP. Procedural Factors That Affect Psychophysical Measures of Spatial Selectivity in Cochlear Implant Users. Trends Hear 2015; 19:19/0/2331216515607067. [PMID: 26420785 PMCID: PMC4593626 DOI: 10.1177/2331216515607067] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Behavioral measures of spatial selectivity in cochlear implants are important both for guiding the programing of individual users’ implants and for the evaluation of different stimulation methods. However, the methods used are subject to a number of confounding factors that can contaminate estimates of spatial selectivity. These factors include off-site listening, charge interactions between masker and probe pulses in interleaved masking paradigms, and confusion effects in forward masking. We review the effects of these confounds and discuss methods for minimizing them. We describe one such method in which the level of a 125-pps masker is adjusted so as to mask a 125-pps probe, and where the masker and probe pulses are temporally interleaved. Five experiments describe the method and evaluate the potential roles of the different potential confounding factors. No evidence was obtained for off-site listening of the type observed in acoustic hearing. The choice of the masking paradigm was shown to alter the measured spatial selectivity. For short gaps between masker and probe pulses, both facilitation and refractory mechanisms had an effect on masking; this finding should inform the choice of stimulation rate in interleaved masking experiments. No evidence for confusion effects in forward masking was revealed. It is concluded that the proposed method avoids many potential confounds but that the choice of method should depend on the research question under investigation.
Collapse
Affiliation(s)
| | - John M Deeks
- MRC Cognition and Brain Sciences Unit, Cambridge, UK
| | | |
Collapse
|
18
|
Schatzer R, Koroleva I, Griessner A, Levin S, Kusovkov V, Yanov Y, Zierhofer C. Speech perception with interaction-compensated simultaneous stimulation and long pulse durations in cochlear implant users. Hear Res 2014; 322:99-106. [PMID: 25457654 DOI: 10.1016/j.heares.2014.11.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2014] [Revised: 10/24/2014] [Accepted: 11/05/2014] [Indexed: 11/24/2022]
Abstract
Early multi-channel designs in the history of cochlear implant development were based on a vocoder-type processing of frequency channels and presented bands of compressed analog stimulus waveforms simultaneously on multiple tonotopically arranged electrodes. The realization that the direct summation of electrical fields as a result of simultaneous electrode stimulation exacerbates interactions among the stimulation channels and limits cochlear implant outcome led to the breakthrough in the development of cochlear implants, the continuous interleaved (CIS) sampling coding strategy. By interleaving stimulation pulses across electrodes, CIS activates only a single electrode at each point in time, preventing a direct summation of electrical fields and hence the primary component of channel interactions. In this paper we show that a previously presented approach of simultaneous stimulation with channel interaction compensation (CIC) may also ameliorate the deleterious effects of simultaneous channel interaction on speech perception. In an acute study conducted in eleven experienced MED-EL implant users, configurations involving simultaneous stimulation with CIC and doubled pulse phase durations have been investigated. As pairs of electrodes were activated simultaneously and pulse durations were doubled, carrier rates remained the same. Comparison conditions involved both CIS and fine structure (FS) strategies, either with strictly sequential or paired-simultaneous stimulation. Results showed no statistical difference in the perception of sentences in noise and monosyllables for sequential and paired-simultaneous stimulation with doubled phase durations. This suggests that CIC can largely compensate for the effects of simultaneous channel interaction, for both CIS and FS coding strategies. A simultaneous stimulation paradigm has a number of potential advantages over a traditional sequential interleaved design. The flexibility gained when dropping the requirement of interleaving pulses across electrodes may be instrumental in designing coding strategies for a more accurate transmission of stimulus features such as temporal fine structure or interaural time delays to the auditory nerve. Also, longer pulse phase durations may be implemented while maintaining relatively high stimulation pulse rates. Utilizing longer pulse durations may relax requirements on implant compliance and facilitate the design of more energy-efficient implant receivers for a longer battery lifetime or a reduction in implant size. This article is part of a Special Issue entitled <Lasker Award>.
Collapse
Affiliation(s)
- Reinhold Schatzer
- Institute of Mechatronics, University of Innsbruck, Technikerstraβe 13, 6020 Innsbruck, Austria; MED-EL GmbH, Fürstenweg 77a, 6020 Innsbruck, Austria
| | - Inna Koroleva
- St. Petersburg ENT and Speech Research Institute, Bronnitskaja 9, 198013 St. Petersburg, Russia.
| | - Andreas Griessner
- Institute of Mechatronics, University of Innsbruck, Technikerstraβe 13, 6020 Innsbruck, Austria
| | - Sergey Levin
- St. Petersburg ENT and Speech Research Institute, Bronnitskaja 9, 198013 St. Petersburg, Russia
| | - Vladislav Kusovkov
- St. Petersburg ENT and Speech Research Institute, Bronnitskaja 9, 198013 St. Petersburg, Russia
| | - Yuri Yanov
- St. Petersburg ENT and Speech Research Institute, Bronnitskaja 9, 198013 St. Petersburg, Russia
| | - Clemens Zierhofer
- Institute of Mechatronics, University of Innsbruck, Technikerstraβe 13, 6020 Innsbruck, Austria
| |
Collapse
|
19
|
van der Beek FB, Briaire JJ, Frijns JHM. Population-based prediction of fitting levels for individual cochlear implant recipients. Audiol Neurootol 2014; 20:1-16. [PMID: 25413720 DOI: 10.1159/000362779] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2012] [Accepted: 04/09/2014] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVES This study analyzed the predictability of fitting levels for cochlear implant recipients based on a review of the clinical levels of the recipients. DESIGN Data containing threshold levels (T-levels) and maximum comfort levels (M-levels) for 151 adult subjects using a CII/HiRes 90K cochlear implant with a HiFocus 1/1 J electrode were used. The 10th, 25th, 50th, 75th and 90th percentiles of the T- and M-levels are reported. Speech perception of the subjects, using a HiRes speech coding strategy, was measured during routine clinical follow-up. RESULTS T-levels for most subjects were between 20 and 35% of their M-levels and were rarely (<1/50) below 10% of the M-levels. Furthermore, both T- and M-levels showed an increase over the first year of follow-up. Interestingly, levels expressed in linear charge units showed a clear increase in dynamic range (DR) over 1 year (29.8 CU; SD 73.0), whereas the DR expressed in decibels remained stable. T-level and DR were the only fitting parameters for which a significant correlation with speech perception (r = 0.34, p < 0.01, and r = 0.33, p < 0.01, respectively) could be demonstrated. Additionally, analysis showed that T- and M-level profiles expressed in decibels were independent of the subjects' across-site mean levels. Using mixed linear models, predictive models were obtained for the T- and M-levels of all separate electrode contacts. CONCLUSIONS On the basis of the data set from 151 subjects, clinically applicable predictive models for T- and M-levels have been obtained. Based on one psychophysical measurement and a population-based T- or M-level profile, individual recipients' T- and M-levels can be approximated with a closed-set formula. Additionally, the analyzed fitting level data can serve as a reference for future patients.
Collapse
Affiliation(s)
- Feddo B van der Beek
- Department of Otolaryngology, Leiden University Medical Center, Leiden, The Netherlands
| | | | | |
Collapse
|
20
|
Can ECAP measures be used for totally objective programming of cochlear implants? J Assoc Res Otolaryngol 2013; 14:879-90. [PMID: 24048907 PMCID: PMC3825020 DOI: 10.1007/s10162-013-0417-9] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2013] [Accepted: 09/06/2013] [Indexed: 11/23/2022] Open
Abstract
An experiment was conducted with eight cochlear implant subjects to investigate the feasibility of using electrically evoked compound action potential (ECAP) measures other than ECAP thresholds to predict the way that behavioral thresholds change with rate of stimulation, and hence, whether they can be used without combination with behavioral measures to determine program stimulus levels for cochlear implants. Loudness models indicate that two peripheral neural response characteristics contribute to the slope of the threshold versus rate function: the way that neural activity to each stimulus pulse decreases as rate increases and the slope of the neural response versus stimulus current function. ECAP measures related to these two characteristics were measured: the way that ECAP amplitude decreases with stimulus rate and the ECAP amplitude growth function, respectively. A loudness model (incorporating temporal integration and the two neural response characteristics) and regression analyses were used to evaluate whether the ECAP measures could predict the average slope of the behavioral threshold versus current function and whether individual variation in the measures could predict individual variation in the slope of the threshold function. The average change of behavioral threshold with increasing rate was well predicted by the model when using the average ECAP data. However, the individual variations in the slope of the thresholds versus rate functions were not well predicted by individual variations in ECAP data. It was concluded that these ECAP measures are not useful for fully objective programming, possibly because they do not accurately reflect the neural response characteristics assumed by the model, or are measured at current levels much higher than threshold currents.
Collapse
|
21
|
The polarity sensitivity of the electrically stimulated human auditory nerve measured at the level of the brainstem. J Assoc Res Otolaryngol 2013; 14:359-77. [PMID: 23479187 DOI: 10.1007/s10162-013-0377-0] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2012] [Accepted: 01/31/2013] [Indexed: 10/27/2022] Open
Abstract
Recent behavioral studies have suggested that the human auditory nerve of cochlear implant (CI) users is mainly excited by the positive (anodic) polarity. Those findings were only obtained using asymmetric pseudomonophasic (PS) pulses where the effect of one phase was measured in the presence of a counteracting phase of opposite polarity, longer duration, and lower amplitude than the former phase. It was assumed that only the short high-amplitude phase was responsible for the excitation. Similarly, it has been shown that electrically evoked compound action potentials could only be obtained in response to the anodic phases of asymmetric pulses. Here, experiment 1 measured electrically evoked auditory brainstem responses to standard symmetric, PS, reversed pseudomonophasic, and reversed pseudomonophasic with inter-phase gap (6 ms) pulses presented for both polarities. Responses were time locked to the short high-amplitude phase of asymmetric pulses and were smaller, but still measurable, when that phase was cathodic than when it was anodic. This provides the first evidence that cathodic stimulation can excite the auditory system of human CI listeners and confirms that this stimulation is nevertheless less effective than for the anodic polarity. A second experiment studied the polarity sensitivity at different intensities by means of a loudness balancing task between pseudomonophasic anodic (PSA) and pseudomonophasic cathodic (PSC) stimuli. Previous studies had demonstrated greater sensitivity to anodic stimulation only for stimuli producing loud percepts. The results showed that PSC stimuli required higher amplitudes than PSA stimuli to reach the same loudness and that this held for current levels ranging from 10 to 100% of the dynamic range.
Collapse
|