Xu H, Ke W, Zhang D, Miao J, Wang B, Yang C. Biomechanical Effects of Different Prosthesis Types and Fixation Ranges in Multisegmental Total En Bloc Spondylectomy: A Finite Element Study. Orthop Surg 2024. [PMID: 39101231 DOI: 10.1111/os.14171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 06/29/2024] [Accepted: 07/02/2024] [Indexed: 08/06/2024] Open
Abstract
OBJECTIVE Multi-segmental total en bloc spondylectomy (TES) gradually became more commonly used by clinicians. However, the choice of surgical strategy is unclear. This study aims to investigate the biomechanical performance of different prosthesis types and fixation ranges in multisegmental TES. METHODS In this study, a validated finite element model of T12-L2 post-spondylectomy operations were carried out. The prostheses of these models used either 3D-printed artificial vertebrae or titanium mesh cages. The fixed range was two or three segment levels. Range of motion, stress distribution of the endplate and internal fixation system, intervertebral disc pressure, and facet joint surface force of four postoperative models and intact model in flexion and extension, as well as lateral bending and rotation were analyzed and compared. RESULTS The type of prosthesis used in the anterior column reconstruction mainly affected the stress of the adjacent endplate and the prosthesis itself. The posterior fixation range had a greater influence on the overall range of motion (ROM), the ROM of the adjacent segment, the stress of the screw-rod system, and adjacent facet joint surface force. For the model of the same prosthesis, the increase of fixed length resulted in an obvious reduction of ROM. The maximal decrease was 70.23% during extension, and the minimal decrease was 30.19% during rotation. CONCLUSION In three-segment TES, the surgical strategy of using 3D-printed artificial prosthesis for anterior column support and pedicle screws for posterior fixation at both two upper and lower levels respectively can reduce the stress on internal fixation system, endplates, and adjacent intervertebral discs, resulting in a reduced risk of internal fixation failure, and ASD development.
Collapse
Affiliation(s)
- Hanpeng Xu
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Wencan Ke
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Dongzhe Zhang
- Tianjin Hospital, Tianjin University, Tianjin, China
| | - Jun Miao
- Tianjin Hospital, Tianjin University, Tianjin, China
| | - Bingjin Wang
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Cao Yang
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
2
|
Wang J, Meng B, Wang X, Lei W, Zhao X. In vivo study of a novel 3D-printed motion-preservation artificial cervical corpectomy construct: short-term imaging and biocompatibility evaluations in a goat model. J Orthop Surg Res 2024; 19:318. [PMID: 38807224 DOI: 10.1186/s13018-024-04786-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2024] [Accepted: 05/07/2024] [Indexed: 05/30/2024] Open
Abstract
BACKGROUND Nonfusion technologies, such as motion-preservation devices, have begun a new era of treatment options in spine surgery. Motion-preservation approaches mainly include total disc replacement for anterior cervical discectomy and fusion. However, for multisegment fusion, such as anterior cervical corpectomy and fusion, the options are more limited. Therefore, we designed a novel 3D-printed motion-preservation artificial cervical corpectomy construct (ACCC) for multisegment fusion. The aim of this study was to explore the feasibility of ACCC in a goat model. METHODS Goats were treated with anterior C3 corpectomy and ACCC implantation and randomly divided into two groups evaluated at 3 or 6 months. Radiography, 3D CT reconstruction and MRI evaluations were performed. Biocompatibility was evaluated using micro-CT and histology. RESULTS Postoperatively, all goats were in good condition, with free neck movement. Implant positioning was optimal. The relationship between facet joints was stable. The range of motion of the C2-C4 segments during flexion-extension at 3 and 6 months postoperatively was 7.8° and 7.3°, respectively. The implants were wrapped by new bone tissue, which had grown into the porous structure. Cartilage tissue, ossification centres, new blood vessels, and bone mineralization were observed at the porous metal vertebrae-bone interface and in the metal pores. CONCLUSIONS The ACCC provided stabilization while preserving the motion of the functional spinal unit and promoting bone regeneration and vascularization. In this study, the ACCC was used for anterior cervical corpectomy and fusion (ACCF) in a goat model. We hope that this study will propel further research of motion-preservation devices.
Collapse
Affiliation(s)
- Jian Wang
- Department of Orthopaedics, Xijing Hospital, Air Force Military Medical University, Xi'an, 710032, Shaanxi Province, China
- Department of Orthopaedics, Affiliated Hospital of NCO School of Army Medical University, Shijiazhuang, 050047, Hebei Province, China
| | - Bing Meng
- Department of Orthopaedics, Xijing Hospital, Air Force Military Medical University, Xi'an, 710032, Shaanxi Province, China
| | - Xinli Wang
- Department of Orthopaedics, Xijing Hospital, Air Force Military Medical University, Xi'an, 710032, Shaanxi Province, China
| | - Wei Lei
- Department of Orthopaedics, Xijing Hospital, Air Force Military Medical University, Xi'an, 710032, Shaanxi Province, China.
| | - Xiong Zhao
- Department of Orthopaedics, Xijing Hospital, Air Force Military Medical University, Xi'an, 710032, Shaanxi Province, China.
| |
Collapse
|
3
|
Gupta R, Judkins L, Friday CS, Ulsh JB, Kovach SJ, Mehta S, Tomonto C, Manogharan G, Hast MW. Functionally graded 3D printed plates for rib fracture fixation. Clin Biomech (Bristol, Avon) 2024; 111:106151. [PMID: 37989063 PMCID: PMC10842059 DOI: 10.1016/j.clinbiomech.2023.106151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 11/09/2023] [Accepted: 11/10/2023] [Indexed: 11/23/2023]
Abstract
BACKGROUND Design freedom offered by additive manufacturing allows for the implementation of functional gradients - where mechanical stiffness is decreased along the length of the implant. It is unclear if such changes will influence failure mechanisms in the context of rib fracture repair. We hypothesized that our novel functionally graded rib implants would be less stiff than controls and decrease occurrence of secondary fracture at implant ends. METHODS Five novel additively manufactured rib implants were tested along with a clinically used Control implant. Fracture reconstructions were modeled with custom synthetic rib bones with a transverse B1 fracture. Ribs were compressed in a cyclic two-point bend test for 360,000 cycles followed by a ramp to failure test. Differences in cyclic stiffness, 3D interfragmentary motions, ramp-to-failure stiffness, maximum load, and work to failure were determined. FINDINGS The Control group had lower construct stiffness (0.76 ± 0.28 N/mm), compared to all novel implant designs (means: 1.35-1.61 N/mm, p < 0.05) and rotated significantly more about the bending axis (2.7° ± 1.3°) than the additively manufactured groups (means between 1.2° - 1.6°, p < 0.05). All constructs failed via bone fracture at the most posterior screw hole. Experimental implants were stiffer than Controls, and there were few significant differences between functional gradient groups. INTERPRETATION Additively manufactured, functionally graded designs have the potential to change the form and function of trauma implants. Here, the impact of functional gradients was limited because implants had small cross-sectional areas.
Collapse
Affiliation(s)
- Richa Gupta
- McKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | - Lauren Judkins
- Department of Mechanical Engineering, Pennsylvania State University, University Park, PA, USA
| | - Chet S Friday
- McKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | - Joseph B Ulsh
- McKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | - Stephen J Kovach
- McKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | - Samir Mehta
- McKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Guha Manogharan
- Department of Mechanical Engineering, Pennsylvania State University, University Park, PA, USA
| | - Michael W Hast
- McKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|
4
|
周 华, 王 仁, 刘 忠, 刘 晓, 吴 奉, 党 礌, 韦 峰. [3D-printed vertebral body in anterior spinal reconstruction after total spondylectomy for patients with cervical chordoma]. BEIJING DA XUE XUE BAO. YI XUE BAN = JOURNAL OF PEKING UNIVERSITY. HEALTH SCIENCES 2023; 55:144-148. [PMID: 36718703 PMCID: PMC9894787 DOI: 10.19723/j.issn.1671-167x.2023.01.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Indexed: 08/22/2024]
Abstract
OBJECTIVE To investigate whether 3D-printed artificial vertebral body can reduce prosthesis subsidence rate for patients with cervical chordomas, through comparing the rates of prosthesis subsidence between 3D printing artificial vertebral body and titanium mesh for anterior spinal reconstruction after total spondylectomy. METHODS This was a retrospective analysis of patients who underwent surgical treatment for cervical chordoma at our hospital from March 2005 to September 2019. There were nine patients in the group of 3D artificial vertebral body (3D group), and 15 patients in the group of titanium mesh cage (Mesh group). The patients' characteristics and treatment data were extracted from the medical records, including age, gender, CT hounsfield unit of cervical vertebra and surgical information, such as the surgical segments, time and blood loss of surgery, frequency and degree of prosthesis subsidence after surgery. Radiographic observations of prosthesis subsidence during the follow-up, including X-rays, CT, and magnetic resonance imaging were also collected. SPSS 22.0 was used to analysis the data. RESULTS There was no significant difference between the two groups in gender, age, CT hounsfield unit, surgical segments, time of surgery, blood loss of posterior surgery and total blood loss. Blood loss of anterior surgery was 700 (300, 825) mL in 3D group and 1 500 (750, 2 800) mL in Mesh group (P < 0.05). The prosthesis subsidence during the follow-up, 3 months after surgery, there was significant difference between the two groups in mild prosthesis subsidence (P < 0.05). The vertebral height of the 3D group decreased less than 1 mm in eight cases (no prosthesis subsidence) and more than 1 mm in one case (mild prosthesis subsidence). The vertebral height of the Mesh group decreased less than 1 mm in five cases (no prosthesis subsidence), and more than 1 mm in eight cases (mild prosthesis subsidence). Two patients did not have X-rays in 3 months after surgery. There was a statistically significant difference between the two groups in the prosthesis subsidence rate at the end of 12 months (P < 0.01). The vertebral height of eight cases in the 3D group decreased less than 1 mm (no prosthesis subsidence) and one case more than 3 mm (severe prosthesis subsidence). Four of the 15 cases in the Mesh group decreased less than 1 mm (no prosthesis subsidence), two cases more than 1 mm (mild prosthesis subsidence), and nine cases more than 3 mm (severe prosthesis subsidence). There was a statistically significant difference between the two groups in the prosthesis subsidence rate at the end of 24 months (P < 0.01). The vertebral height of seven cases in the 3D group decreased less than 1 mm (no prosthesis subsidence), one case more than 3 mm (severe prosthesis subsidence), and one case died with tumor. One case in the Mesh group decreased less than 1 mm (no prosthesis subsidence), one case more than 1 mm (mild prosthesis subsidence), 11 case more than 3 mm (severe prosthesis subsidence), one case died with tumor and one lost the follow-up. Moreover, at the end of 12 months and 24 months, there was significant difference between the two groups in severe prosthesis subsidence rate (P < 0.01). CONCLUSION 3D-printed artificial vertebral body for anterior spinal reconstruction after total spondylectomy for patients with cervical chordoma can provide reliable spinal stability, and reduce the incidence of prosthesis subsidence after 2-year follow-up.
Collapse
Affiliation(s)
- 华 周
- />北京大学第三医院骨科,骨与关节精准医学工程研究中心,脊柱疾病研究北京市重点实验室,北京 100191Department of Orthopaedics, Peking University Third Hospital; Engineering Research Center of Bone and Joint Precision Medicine; Beijing Key Laboratory of Spinal Disease Research, Beijing 100191, China
| | - 仁吉 王
- />北京大学第三医院骨科,骨与关节精准医学工程研究中心,脊柱疾病研究北京市重点实验室,北京 100191Department of Orthopaedics, Peking University Third Hospital; Engineering Research Center of Bone and Joint Precision Medicine; Beijing Key Laboratory of Spinal Disease Research, Beijing 100191, China
| | - 忠军 刘
- />北京大学第三医院骨科,骨与关节精准医学工程研究中心,脊柱疾病研究北京市重点实验室,北京 100191Department of Orthopaedics, Peking University Third Hospital; Engineering Research Center of Bone and Joint Precision Medicine; Beijing Key Laboratory of Spinal Disease Research, Beijing 100191, China
| | - 晓光 刘
- />北京大学第三医院骨科,骨与关节精准医学工程研究中心,脊柱疾病研究北京市重点实验室,北京 100191Department of Orthopaedics, Peking University Third Hospital; Engineering Research Center of Bone and Joint Precision Medicine; Beijing Key Laboratory of Spinal Disease Research, Beijing 100191, China
| | - 奉梁 吴
- />北京大学第三医院骨科,骨与关节精准医学工程研究中心,脊柱疾病研究北京市重点实验室,北京 100191Department of Orthopaedics, Peking University Third Hospital; Engineering Research Center of Bone and Joint Precision Medicine; Beijing Key Laboratory of Spinal Disease Research, Beijing 100191, China
| | - 礌 党
- />北京大学第三医院骨科,骨与关节精准医学工程研究中心,脊柱疾病研究北京市重点实验室,北京 100191Department of Orthopaedics, Peking University Third Hospital; Engineering Research Center of Bone and Joint Precision Medicine; Beijing Key Laboratory of Spinal Disease Research, Beijing 100191, China
| | - 峰 韦
- />北京大学第三医院骨科,骨与关节精准医学工程研究中心,脊柱疾病研究北京市重点实验室,北京 100191Department of Orthopaedics, Peking University Third Hospital; Engineering Research Center of Bone and Joint Precision Medicine; Beijing Key Laboratory of Spinal Disease Research, Beijing 100191, China
| |
Collapse
|
5
|
Zhang DX, Guo LX. Effect of different fixation methods on biomechanical property of cervical vertebral body replacement and fusion. Clin Biomech (Bristol, Avon) 2023; 101:105864. [PMID: 36563544 DOI: 10.1016/j.clinbiomech.2022.105864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2022] [Revised: 10/25/2022] [Accepted: 12/14/2022] [Indexed: 12/23/2022]
Abstract
BACKGROUND The main purpose of this study was to examine the effect of different fixation methods (anterior fixation, self-stabilizing fixation and anterior-posterior fixation) on biomechanical property of vertebral body replacement and fusion. METHODS Three finite element models of cervical vertebral body replacement and fusion were established. The implanted models included artificial vertebral body and fixation system, and the loads imposed on the models included 75 N compression load and 1 Nm moment load. FINDINGS For anterior-posterior fixation, the cervical load was mainly transmitted by the posterior pedicle screw and rod (more than 50%), and the stress shielding problem was the most significant than the self-stabilizing and anterior fixation. Self-stabilizing fixation was more helpful to the fusion of implant and vertebrae, but the higher risk of vertebral body collapse was worthy of attention if the cervical spine with osteoporosis. The stress of bone was mainly concentrated around the screw hole. The maximum stress (20.03 MPa) was lower than the yield stress of cortical bone and the possibility of fracture around the fixation device of cervical spine was low. The anterior fixation could meet the requirement of vertebral body replacement and fusion, and the addition of posterior pedicle screws and rods might obtain better treatment in cases of severe spine injury or osteoporosis. INTERPRETATION The findings of this study may provide guidance on clinical treatments for choosing more appropriate fixation methods for different patients.
Collapse
Affiliation(s)
- Dong-Xiang Zhang
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang 110819, China
| | - Li-Xin Guo
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang 110819, China.
| |
Collapse
|
6
|
Santos Beato P, Poologasundarampillai G, Nommeots-Nomm A, Kalaskar DM. Materials for 3D printing in medicine: metals, polymers, ceramics, and hydrogels. 3D Print Med 2023. [DOI: 10.1016/b978-0-323-89831-7.00002-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
|
7
|
Davoodi E, Montazerian H, Mirhakimi AS, Zhianmanesh M, Ibhadode O, Shahabad SI, Esmaeilizadeh R, Sarikhani E, Toorandaz S, Sarabi SA, Nasiri R, Zhu Y, Kadkhodapour J, Li B, Khademhosseini A, Toyserkani E. Additively manufactured metallic biomaterials. Bioact Mater 2022; 15:214-249. [PMID: 35386359 PMCID: PMC8941217 DOI: 10.1016/j.bioactmat.2021.12.027] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 12/17/2021] [Accepted: 12/21/2021] [Indexed: 02/06/2023] Open
Abstract
Metal additive manufacturing (AM) has led to an evolution in the design and fabrication of hard tissue substitutes, enabling personalized implants to address each patient's specific needs. In addition, internal pore architectures integrated within additively manufactured scaffolds, have provided an opportunity to further develop and engineer functional implants for better tissue integration, and long-term durability. In this review, the latest advances in different aspects of the design and manufacturing of additively manufactured metallic biomaterials are highlighted. After introducing metal AM processes, biocompatible metals adapted for integration with AM machines are presented. Then, we elaborate on the tools and approaches undertaken for the design of porous scaffold with engineered internal architecture including, topology optimization techniques, as well as unit cell patterns based on lattice networks, and triply periodic minimal surface. Here, the new possibilities brought by the functionally gradient porous structures to meet the conflicting scaffold design requirements are thoroughly discussed. Subsequently, the design constraints and physical characteristics of the additively manufactured constructs are reviewed in terms of input parameters such as design features and AM processing parameters. We assess the proposed applications of additively manufactured implants for regeneration of different tissue types and the efforts made towards their clinical translation. Finally, we conclude the review with the emerging directions and perspectives for further development of AM in the medical industry.
Collapse
Affiliation(s)
- Elham Davoodi
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
- Department of Bioengineering, University of California, Los Angeles, California 90095, United States
- California NanoSystems Institute (CNSI), University of California, Los Angeles, California 90095, United States
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
| | - Hossein Montazerian
- Department of Bioengineering, University of California, Los Angeles, California 90095, United States
- California NanoSystems Institute (CNSI), University of California, Los Angeles, California 90095, United States
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
| | - Anooshe Sadat Mirhakimi
- Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, Isfahan 84156-83111, Iran
| | - Masoud Zhianmanesh
- School of Biomedical Engineering, University of Sydney, Sydney, New South Wales 2006, Australia
| | - Osezua Ibhadode
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Shahriar Imani Shahabad
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Reza Esmaeilizadeh
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Einollah Sarikhani
- Department of Nanoengineering, Jacobs School of Engineering, University of California, San Diego, California 92093, United States
| | - Sahar Toorandaz
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Shima A. Sarabi
- Mechanical and Aerospace Engineering Department, University of California, Los Angeles, California 90095, United States
| | - Rohollah Nasiri
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
| | - Yangzhi Zhu
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
| | - Javad Kadkhodapour
- Department of Mechanical Engineering, Shahid Rajaee Teacher Training University, Tehran, Tehran 16785-163, Iran
- Institute for Materials Testing, Materials Science and Strength of Materials, University of Stuttgart, Stuttgart 70569, Germany
| | - Bingbing Li
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
- Department of Manufacturing Systems Engineering and Management, California State University, Northridge, California 91330, United States
| | - Ali Khademhosseini
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
| | - Ehsan Toyserkani
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
8
|
Zhou H, Liu S, Li Z, Liu X, Dang L, Li Y, Li Z, Hu P, Wang B, Wei F, Liu Z. 3D-printed vertebral body for anterior spinal reconstruction in patients with thoracolumbar spinal tumors. J Neurosurg Spine 2022; 37:274-282. [PMID: 35213828 DOI: 10.3171/2022.1.spine21900] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Accepted: 01/07/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE A 3D-printed vertebral prosthesis can be used to reconstruct a bone defect more precisely because of its tailored shape, with its innermost porous structure inducing bone ingrowth. The aim of this study was to evaluate the clinical outcomes of using a 3D-printed artificial vertebral body for spinal reconstruction after en bloc resection of thoracolumbar tumors. METHODS This was a retrospective analysis of 23 consecutive patients who underwent surgical treatment for thoracolumbar tumors at our hospital. En bloc resection was performed in all cases, based on the Weinstein-Boriani-Biagini surgical staging system, and anterior reconstruction was performed using a 3D-printed artificial vertebral body. Prosthesis subsidence, fusion status, and instrumentation-related complications were evaluated. Stability of the anterior reconstruction method was evaluated by CT, and CT Hounsfield unit (HU) values were measured to evaluate fusion status. RESULTS The median follow-up was 37 (range 24-58) months. A customized 3D-printed artificial vertebral body was used in 10 patients, with an off-the-shelf 3D-printed artificial vertebral body used in the other 13 patients. The artificial vertebral body was implanted anteriorly in 5 patients and posteriorly in 18 patients. The overall fusion rate was 87.0%. The average prosthesis subsidence at the final follow-up was 1.60 ± 1.79 mm. Instrument failure occurred in 2 patients, both of whom had substantial subsidence (8.47 and 3.69 mm, respectively). At 3 months, 6 months, and 1 year postoperatively, the mean CT HU values within the artificial vertebral body were 1930 ± 294, 1997 ± 336, and 1994 ± 257, respectively, with each of these values being significantly higher than the immediate postoperative value of 1744 ± 321 (p < 0.05). CONCLUSIONS The use of a 3D-printed artificial vertebral body for anterior reconstruction after en bloc resection of the thoracolumbar spinal tumor may be a feasible and reliable option. The low incidence of prosthesis subsidence of 3D-printed endoprostheses can provide good stability instantly. Measurement of HU values with CT is a valuable method to evaluate the osseointegration at the bone-metal interface of a 3D-printed vertebral prosthesis.
Collapse
Affiliation(s)
- Hua Zhou
- 1Department of Orthopaedics, Peking University Third Hospital, Beijing
- 2Engineering Research Center of Bone and Joint Precision Medicine, Beijing
- 3Beijing Key Laboratory of Spinal Disease Research, Beijing; and
| | - Shanshan Liu
- 1Department of Orthopaedics, Peking University Third Hospital, Beijing
- 2Engineering Research Center of Bone and Joint Precision Medicine, Beijing
- 3Beijing Key Laboratory of Spinal Disease Research, Beijing; and
| | - Zhehuang Li
- 4Department of Bone and Soft Tumor, Affiliated Cancer Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Xiaoguang Liu
- 1Department of Orthopaedics, Peking University Third Hospital, Beijing
- 2Engineering Research Center of Bone and Joint Precision Medicine, Beijing
- 3Beijing Key Laboratory of Spinal Disease Research, Beijing; and
| | - Lei Dang
- 1Department of Orthopaedics, Peking University Third Hospital, Beijing
- 2Engineering Research Center of Bone and Joint Precision Medicine, Beijing
- 3Beijing Key Laboratory of Spinal Disease Research, Beijing; and
| | - Yan Li
- 1Department of Orthopaedics, Peking University Third Hospital, Beijing
- 2Engineering Research Center of Bone and Joint Precision Medicine, Beijing
- 3Beijing Key Laboratory of Spinal Disease Research, Beijing; and
| | - Zihe Li
- 1Department of Orthopaedics, Peking University Third Hospital, Beijing
- 2Engineering Research Center of Bone and Joint Precision Medicine, Beijing
- 3Beijing Key Laboratory of Spinal Disease Research, Beijing; and
| | - Panpan Hu
- 1Department of Orthopaedics, Peking University Third Hospital, Beijing
- 2Engineering Research Center of Bone and Joint Precision Medicine, Beijing
- 3Beijing Key Laboratory of Spinal Disease Research, Beijing; and
| | - Ben Wang
- 1Department of Orthopaedics, Peking University Third Hospital, Beijing
- 2Engineering Research Center of Bone and Joint Precision Medicine, Beijing
- 3Beijing Key Laboratory of Spinal Disease Research, Beijing; and
| | - Feng Wei
- 1Department of Orthopaedics, Peking University Third Hospital, Beijing
- 2Engineering Research Center of Bone and Joint Precision Medicine, Beijing
- 3Beijing Key Laboratory of Spinal Disease Research, Beijing; and
| | - Zhongjun Liu
- 1Department of Orthopaedics, Peking University Third Hospital, Beijing
- 2Engineering Research Center of Bone and Joint Precision Medicine, Beijing
- 3Beijing Key Laboratory of Spinal Disease Research, Beijing; and
| |
Collapse
|
9
|
He X, Obeng E, Sun X, Kwon N, Shen J, Yoon J. Polydopamine, harness of the antibacterial potentials-A review. Mater Today Bio 2022; 15:100329. [PMID: 35757029 PMCID: PMC9218838 DOI: 10.1016/j.mtbio.2022.100329] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 06/10/2022] [Accepted: 06/11/2022] [Indexed: 11/11/2022] Open
Abstract
Antibiotic resistance is one of the major causes of morbidity and mortality, triggered by the adhesion of microbes and to some extent the formation of biofilms. This condition has been quite challenging in the health and industrial sector. Conditions and processes required to foil these infectious and resistance are of much concern. The synthesis of PDA material, inspired by the Mytilus edulis foot protein (MEFP)5 possesses unique characteristics that allow for, adhesion, photothermal therapy, synergistic effects with other materials, biocompatibility process, etc. Therefore, their usage holds great potential for dealing with both the infectious nature and the antibiotic resistance processes. Hence, this review provides an overview of the mechanism involved in accomplishing and eradicating bacteria, the recently harnessed antibacterial effect of the PDA through other properties they possess, a way forward in tapping the benefit embedded in the PDA, and the future perspective.
Collapse
Affiliation(s)
- Xiaojun He
- School of Ophthalmology & Optometry, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, Zhejiang, 325035, China
| | - Enoch Obeng
- School of Ophthalmology & Optometry, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, Zhejiang, 325035, China
| | - Xiaoshuai Sun
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang, 325000, China
| | - Nahyun Kwon
- Department of Chemistry and Nano Science, Ewha Womans University, Seoul, 03760, Republic of Korea
| | - Jianliang Shen
- School of Ophthalmology & Optometry, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, Zhejiang, 325035, China
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang, 325000, China
- Oujiang Laboratory (Zhejiang Lab for Regenerative Medicine, Vision and Brain Health), Wenzhou, Zhejiang, 325001, China
| | - Juyoung Yoon
- Department of Chemistry and Nano Science, Ewha Womans University, Seoul, 03760, Republic of Korea
| |
Collapse
|
10
|
Lv J, Jin W, Liu W, Qin X, Feng Y, Bai J, Wu Z, Li J. Selective Laser Melting Fabrication of Porous Ti6Al4V Scaffolds With Triply Periodic Minimal Surface Architectures: Structural Features, Cytocompatibility, and Osteogenesis. Front Bioeng Biotechnol 2022; 10:899531. [PMID: 35694229 PMCID: PMC9178116 DOI: 10.3389/fbioe.2022.899531] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 05/02/2022] [Indexed: 11/24/2022] Open
Abstract
The relationship between pore architecture and structure performance needs to be explored, as well as confirm the optimized porous structure. Because of the linear correlation between constant C and pore architecture, triply periodic minimal surface (TPMS) based porous structures could be a controllable model for the investigation of the optimized porous structure. In the present work, three types of TPMS porous scaffolds (S, D and G) combined with four constants (0.0, 0.2, 0.4 and 0.6) were designed, and built successfully via the selective laser melting (SLM) technology. The designed feature and mechanical property of porous scaffolds were investigated through mathematical method and compression test. And the manufactured samples were co-cultured with rMSCs for the compatibility study. The results indicated that the whole manufacturing procedure was good in controllability, repeatability, and accuracy. The linear correlation between the porosity of TPMS porous scaffolds and the constant C in equations was established. The different TPMS porous scaffolds possess the disparate feature in structure, mechanical property and cell compatibility. Comprehensive consideration of the structure features, mechanical property and biology performance, different TPMS structures should be applied in appropriate field. The results could guide the feasibility of apply the different TPMS architectures into the different part of orthopedic implants.
Collapse
Affiliation(s)
- Jia Lv
- Department of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China
- *Correspondence: Jia Lv,
| | - Wenxuan Jin
- Department of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Wenhao Liu
- Department of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Xiuyu Qin
- Shanxi Key Laboratory of Bone and Soft Tissue Injury Repair, Department of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Yi Feng
- Department of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Junjun Bai
- Department of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Zhuangzhuang Wu
- Department of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China
| | - Jian Li
- Department of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China
| |
Collapse
|
11
|
Jian Q, Liu Z, Duan W, Guan J, Jian F, Chen Z. Reconstruction of the cervical lateral mass using 3D-printed prostheses. Neurospine 2022; 19:202-211. [PMID: 35130422 PMCID: PMC8987545 DOI: 10.14245/ns.2143008.504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 12/28/2021] [Indexed: 11/20/2022] Open
Abstract
Objective This study aimed to investigate the outcome of using 3-dimensional (3D)-printed prostheses to reconstruct a cervical lateral mass to maintain cervical stability.
Methods We retrospectively analyzed data of 7 patients who underwent cervical lateral mass reconstruction using a 3D-printed prosthesis, comprising axial and subaxial lateral mass reconstruction in 2 and 5 patients, respectively. Bilateral mass was reconstructed in 1 patient and unilateral mass in the remaining 6 patients.
Results Using a 3D-printed lateral mass prosthesis, internal fixation was stable for all 7 patients postoperatively. No implant-related complications such as prosthesis loosening, displacement, and compression were observed at the last follow-up.
Conclusion Reconstruction of the lateral mass structure is beneficial in restoring load transfer in the cervical spine under physiological conditions. A 3D-printed prosthesis can be considered a good option for reconstruction of the lateral mass as fusion was achieved, with no subsequent complications observed.
Collapse
Affiliation(s)
- Qiang Jian
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Zhenlei Liu
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Wanru Duan
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Jian Guan
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Fengzeng Jian
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Zan Chen
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
- Corresponding Author Zan Chen https://orcid.org/0000-0002-0104-115X Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, No. 45, Changchun Street, Xicheng District, Beijing 100053, China
| |
Collapse
|
12
|
Hou G, Liu B, Tian Y, Liu Z, Zhou F. Reconstruction of Ipsilateral Femoral and Tibial Bone Defect by 3D Printed Porous Scaffold Without Bone Graft: A Case Report. JBJS Case Connect 2022; 12:01709767-202203000-00001. [PMID: 34986136 DOI: 10.2106/jbjs.cc.20.00592] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
CASE This study reported the case of a 42-year-old woman with traumatic ipsilateral critical bone defect of right femur and tibia after a motor accident. Three-dimensional (3D) printed porous titanium scaffolds were innovatively used to reconstruct this challenging situation. The initial stability was safe enough for early exercise and partial weight bearing. The 26-month follow-up showed osseous integration of the prosthesis-bone interface with short-term satisfactory clinical result. CONCLUSION The custom-designed 3D-printed porous scaffold has the potential to become an effective option for reconstructing the segmental irregular-shaped bone defect.
Collapse
Affiliation(s)
- Guojin Hou
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China.,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, China
| | - Bingchuan Liu
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China.,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, China
| | - Yun Tian
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China.,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, China
| | - Zhongjun Liu
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China.,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, China
| | - Fang Zhou
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China.,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, China
| |
Collapse
|
13
|
Preclinical Evaluation of a Novel 3D-Printed Movable Lumbar Vertebral Complex for Replacement: In Vivo and Biomechanical Evaluation of Goat Model. BIOMED RESEARCH INTERNATIONAL 2021; 2021:2343404. [PMID: 34926682 PMCID: PMC8683181 DOI: 10.1155/2021/2343404] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Accepted: 11/29/2021] [Indexed: 11/17/2022]
Abstract
Purpose This was an in vivo study to develop a novel movable lumbar artificial vertebral complex (MLVC) in a goat model. The purpose of this study was to evaluate clinical and biomechanical characteristics of MLVC and to provide preclinical data for a clinical trial in the future. Methods According to the preoperative X-ray and CT scan data of the lumbar vertebrae, 3D printing of a MLVC was designed and implanted in goats. The animals were randomly divided into three groups: intact, fusion, and nonfusion. In the intact group, only the lumbar vertebrae and intervertebral discs were exposed during surgery. Both the fusion and nonfusion groups underwent resection of the lumbar vertebral body and the adjacent intervertebral disc. Titanium cages and lateral plates were implanted in the fusion group. MLVC was implanted in the nonfusion group. All groups were evaluated by CT scan and micro-CT to observe the spinal fusion and tested using the mechanical tester at 6 months after operation. Results The imaging results showed that with the centrum, the artificial endplates of the titanium cage and MLVC formed compact bone trabeculae. In the in vitro biomechanical test, the average ROM of L3-4 and L4-5 for the nonfusion group was found to be similar to that of the intact group and significantly higher in comparison to that of the fusion group (P < 0.05). The average ROM of flexion, extension, lateral bending, and rotation in the L2-3 intervertebral space significantly increased in the fusion group compared with the intact group and the nonfusion group (P < 0.001). There were no significant differences in flexion, extension, lateral bending, and rotation between the nonfusion and intact groups (P > 0.05). The average ROM of flexion, extension, lateral bending, and rotation in the L2-5 intervertebral space was not significantly different between the intact group, the fusion group, and the nonfusion group, and there was no statistical significance (P > 0.05). HE staining results did not find any metal and polyethylene debris caused by abrasion. Conclusion In vivo MLVC can not only reconstruct the height and stability of the centrum of the operative segment but also retain the movement of the corresponding segment.
Collapse
|
14
|
Comparison of 3D-printed titanium-alloy, standard titanium-alloy, and PEEK interbody spacers in an ovine model. Spine J 2021; 21:2097-2103. [PMID: 34029756 DOI: 10.1016/j.spinee.2021.05.018] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 05/17/2021] [Accepted: 05/19/2021] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Osseointegration is a pivotal process in achieving a rigid fusion and ultimately a successful clinical outcome following interbody fusion surgery. Advancements in 3D printing technology permit commonly used titanium interbody spacers to be designed with unique architectures, such as a highly interconnected and specific porous structure that mimics the architecture of trabecular bone. Interbody implants with a microscale surface roughness and biomimetic porosity may improve bony ongrowth and ingrowth compared to traditional materials. PURPOSE The purpose of this study was to compare the osseointegration of lumbar interbody fusion devices composed of surgical-grade polyetheretherketone (PEEK), titanium-alloy (TAV), and 3D-printed porous, biomimetic TAV (3DP) using an in vivo ovine model. STUDY DESIGN In Vivo Preclinical Animal Study METHODS: Eighteen sheep underwent two-level lateral lumbar interbody fusion randomized with either 3DP, PEEK, or TAV interbody spacers (n=6 levels for each spacer per time point). Postoperative time points were 6 and 12 weeks. Microcomputed tomography and histomorphometry were used to quantify bone volume (BV) within the spacers (ingrowth) and the surface bone apposition ratio (BAR) (ongrowth), respectively. RESULTS The 3DP-treatment group demonstrated significantly higher BV than the PEEK and TAV groups at 6 weeks (77.3±44.1 mm3, 116.9±43.0 mm3, and 108.7±15.2 mm3, respectively) (p<.05). At 12 weeks, there were no BV differences between groups (p>.05). BV increased in all groups from the 6- to 12-week time points (p<.05). At both time points, the 3DP-treated group (6w: 23.6±10.9%; 12w: 36.5±10.9%) had significantly greater BAR than the PEEK (6w: 8.6±2.1%; 12w: 14.0±5.0%) and TAV (6w: 6.0±5.7%; 12w: 4.1±3.3%) groups (p<.05). CONCLUSIONS 3DP interbody spacers facilitated greater total bony ingrowth at 6 weeks, and greater bony ongrowth postoperatively at both 6 and 12 weeks, in comparison to solid PEEK and TAV implants. CLINICAL SIGNIFICANCE Based on these findings, the 3DP spacers may be a reasonable alternative to traditional PEEK and TAV spacers in various clinical applications of interbody fusion.
Collapse
|
15
|
Hossain U, Ghouse S, Nai K, Jeffers JR. Mechanical and morphological properties of additively manufactured SS316L and Ti6Al4V micro-struts as a function of build angle. ADDITIVE MANUFACTURING 2021; 46:None. [PMID: 34603974 PMCID: PMC8448581 DOI: 10.1016/j.addma.2021.102050] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 05/05/2021] [Accepted: 05/10/2021] [Indexed: 06/13/2023]
Abstract
Additive manufacturing methods such as laser powder bed fusion (PBF) can produce micro-lattice structures which consist of 'micro-struts', which have properties that differ from the bulk metal and that can vary depending on the orientation of the strut to the build direction (the strut build angle). Characterizing these mechanical and morphological changes would help explain macro-scale lattice behavior. Individual stainless steel (SS316L) and titanium alloy (Ti6Al4V) laser PBF struts were built at 20°, 40°, 70° and 90° to the build platform, with 3 designed diameters and tested in uniaxial tension (n = 5). Micro-CT was used to quantify changes in surface roughness, eccentricity and cross-section. Average elastic modulus was 61.5 GPa and 37.5 GPa for SS316L and Ti6Al4V respectively, less than the bulk material. Yield strength was uniform over build angle for SS316L, but for Ti6Al4V varied from 40% to 98% of the bulk value from 20° to 90° build angles. All lower angle struts had worse morphology, with higher roughness and less circular cross-sections. These data should help inform micro-lattice design, especially in safety critical applications where lower mechanical performance must be compensated for.
Collapse
Affiliation(s)
- Umar Hossain
- Department of Mechanical Engineering, Imperial College London, South Kensington, London SW7 2AZ, UK
| | - Shaaz Ghouse
- Department of Mechanical Engineering, Imperial College London, South Kensington, London SW7 2AZ, UK
| | - Kenneth Nai
- Renishaw PLC, New Mills, Wotton-under-Edge, Gloucestershire GL12 8JR, UK
| | - Jonathan R.T. Jeffers
- Department of Mechanical Engineering, Imperial College London, South Kensington, London SW7 2AZ, UK
| |
Collapse
|
16
|
Jin Y, Zhao B, Lu X, Zhao Y, Zhao X, Wang X, Zhou R, Qi D, Wang W. Mid- and Long-Term Follow-Up Efficacy Analysis of 3D-Printed Interbody Fusion Cages for Anterior Cervical Discectomy and Fusion. Orthop Surg 2021; 13:1969-1978. [PMID: 34523808 PMCID: PMC8528997 DOI: 10.1111/os.13005] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 03/01/2021] [Accepted: 03/09/2021] [Indexed: 11/29/2022] Open
Abstract
OBJECTIVE To evaluate the safety and stability of 3D-printed interbody fusion cages (3D-printed cages) in anterior cervical discectomy and fusion (ACDF) by investigating the mid- and long-term follow-up outcomes. METHODS In this prospective study, the clinical data of 30 patients with CSM admitted to the Second Hospital of Shanxi Medical University from May 2012 to May 2014 were analyzed. The cohort comprised 18 males and 12 females with an average age of 60.22 ± 3.2 years. All patients were examined by X-ray, CT and MRI before the operation. A total of 30 cases of CSM were treated by ACDF with 3D printed cage implantation. Mid- and long-term follow-ups were performed after the surgery. Clinical efficacy was evaluated by comparing the JOA score, SF-36 score, change in neurological function, cervical curvature index (CCI), vertebral intervertebral height (VIH) and fusion rate before the operation, 6 months after the operation, and at the last follow-up. RESULTS Two of the 30 patients were lost to follow-up. The remaining patients were followed up for 48-76 (65.23 ± 3.54) months. The patients recovered satisfactorily with a significant clinical effect. The JOA score increased meanfully and the improvement rate was 89.4% at the final follow-up. The SF-36 score increased significantly from pre- to postoperatively. The height of the intervertebral space at the last follow-up was not statistically significantly different from that at 6 months after surgery (P > 0.05), showing that the height of the intervertebral space did not change much and the severity of cage subsidence (CS) decreased. The CCI improved from pre- to postoperatively. The CCI did not change much from the 6-month follow-up to the last follow-up. and the cage rate (CR) was 100% at the 6-month and last follow-ups. No severe complications, such as spinal cord injury, esophageal fistula, cerebrospinal fluid leakage, cervical hematoma or wound infection, occurred in any of the patients. CONCLUSION The clinical and radiological results show that the application of 3D-printed cages in ACDF can significantly relieve symptoms. Moreover, 3D-printed cages can restore the curvature of the cervical spine, effectively maintain the intervertebral height for a long time, and prevent complications related to postoperative subsidence.
Collapse
Affiliation(s)
- Yuan‐zhang Jin
- Department of OrthopaedicsThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Bin Zhao
- Department of OrthopaedicsThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Xiang‐dong Lu
- Department of OrthopaedicsThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Yi‐bo Zhao
- Department of OrthopaedicsThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Xiao‐feng Zhao
- Department of OrthopaedicsThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Xiao‐nan Wang
- Department of OrthopaedicsThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Run‐tian Zhou
- Department of OrthopaedicsThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - De‐tai Qi
- Department of OrthopaedicsThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Wen‐xuan Wang
- Department of OrthopaedicsThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| |
Collapse
|
17
|
Yamaguchi S, Le PTM, Shintani SA, Takadama H, Ito M, Ferraris S, Spriano S. Iodine-Loaded Calcium Titanate for Bone Repair with Sustainable Antibacterial Activity Prepared by Solution and Heat Treatment. NANOMATERIALS 2021; 11:nano11092199. [PMID: 34578515 PMCID: PMC8472594 DOI: 10.3390/nano11092199] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 08/23/2021] [Accepted: 08/25/2021] [Indexed: 11/16/2022]
Abstract
In the orthopedic and dental fields, simultaneously conferring titanium (Ti) and its alloy implants with antibacterial and bone-bonding capabilities is an outstanding challenge. In the present study, we developed a novel combined solution and heat treatment that controllably incorporates 0.7% to 10.5% of iodine into Ti and its alloys by ion exchange with calcium ions in a bioactive calcium titanate. The treated metals formed iodine-containing calcium-deficient calcium titanate with abundant Ti-OH groups on their surfaces. High-resolution XPS analysis revealed that the incorporated iodine ions were mainly positively charged. The surface treatment also induced a shift in the isoelectric point toward a higher pH, which indicated a prevalence of basic surface functionalities. The Ti loaded with 8.6% iodine slowly released 5.6 ppm of iodine over 90 days and exhibited strong antibacterial activity (reduction rate >99%) against methicillin-resistant Staphylococcus aureus (MRSA), S. aureus, Escherichia coli, and S. epidermidis. A long-term stability test of the antibacterial activity on MRSA showed that the treated Ti maintained a >99% reduction until 3 months, and then it gradually decreased after 6 months (to a 97.3% reduction). There was no cytotoxicity in MC3T3-E1 or L929 cells, whereas apatite formed on the treated metal in a simulated body fluid within 3 days. It is expected that the iodine-carrying Ti and its alloys will be particularly useful for orthopedic and dental implants since they reliably bond to bone and prevent infection owing to their apatite formation, cytocompatibility, and sustainable antibacterial activity.
Collapse
Affiliation(s)
- Seiji Yamaguchi
- Department of Biomedical Sciences, College of Life and Health Sciences, Chubu University, 1200 Matsumoto, Kasugai 487-8501, Aichi, Japan; (P.T.M.L.); (S.A.S.); (H.T.); (M.I.)
- Correspondence: ; Tel.: +81-568-51-6420; Fax: +81-568-51-5370
| | - Phuc Thi Minh Le
- Department of Biomedical Sciences, College of Life and Health Sciences, Chubu University, 1200 Matsumoto, Kasugai 487-8501, Aichi, Japan; (P.T.M.L.); (S.A.S.); (H.T.); (M.I.)
| | - Seine A. Shintani
- Department of Biomedical Sciences, College of Life and Health Sciences, Chubu University, 1200 Matsumoto, Kasugai 487-8501, Aichi, Japan; (P.T.M.L.); (S.A.S.); (H.T.); (M.I.)
| | - Hiroaki Takadama
- Department of Biomedical Sciences, College of Life and Health Sciences, Chubu University, 1200 Matsumoto, Kasugai 487-8501, Aichi, Japan; (P.T.M.L.); (S.A.S.); (H.T.); (M.I.)
| | - Morihiro Ito
- Department of Biomedical Sciences, College of Life and Health Sciences, Chubu University, 1200 Matsumoto, Kasugai 487-8501, Aichi, Japan; (P.T.M.L.); (S.A.S.); (H.T.); (M.I.)
| | - Sara Ferraris
- Politecnico di Torino, Corso Duca degli Abruzzi 24, Corso Duca degli Abruzzi 24, 10129 Torino, Italy; (S.F.); (S.S.)
| | - Silvia Spriano
- Politecnico di Torino, Corso Duca degli Abruzzi 24, Corso Duca degli Abruzzi 24, 10129 Torino, Italy; (S.F.); (S.S.)
| |
Collapse
|
18
|
Pharmaceutical electrospinning and 3D printing scaffold design for bone regeneration. Adv Drug Deliv Rev 2021; 174:504-534. [PMID: 33991588 DOI: 10.1016/j.addr.2021.05.007] [Citation(s) in RCA: 128] [Impact Index Per Article: 42.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Revised: 04/26/2021] [Accepted: 05/11/2021] [Indexed: 12/13/2022]
Abstract
Bone regenerative engineering provides a great platform for bone tissue regeneration covering cells, growth factors and other dynamic forces for fabricating scaffolds. Diversified biomaterials and their fabrication methods have emerged for fabricating patient specific bioactive scaffolds with controlled microstructures for bridging complex bone defects. The goal of this review is to summarize the points of scaffold design as well as applications for bone regeneration based on both electrospinning and 3D bioprinting. It first briefly introduces biological characteristics of bone regeneration and summarizes the applications of different types of material and the considerations for bone regeneration including polymers, ceramics, metals and composites. We then discuss electrospinning nanofibrous scaffold applied for the bone regenerative engineering with various properties, components and structures. Meanwhile, diverse design in the 3D bioprinting scaffolds for osteogenesis especially in the role of drug and bioactive factors delivery are assembled. Finally, we discuss challenges and future prospects in the development of electrospinning and 3D bioprinting for osteogenesis and prominent strategies and directions in future.
Collapse
|
19
|
Kang J, Dong E, Li X, Guo Z, Shi L, Li D, Wang L. Topological design and biomechanical evaluation for 3D printed multi-segment artificial vertebral implants. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 127:112250. [PMID: 34225889 DOI: 10.1016/j.msec.2021.112250] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 05/02/2021] [Accepted: 06/07/2021] [Indexed: 12/11/2022]
Abstract
Customized spinal implants fabricated by additive manufacturing have been increasingly used clinically to restore the physiological functions. However, the mechanisms and methods about the design for the spinal implants are not clear, especially for the reconstruction of multi-segment vertebral. This study aims to develop a novel multi-objective optimization methodology based on various normal spinal activities, to design the artificial vertebral implant (AVI) with lightweight, high-strength and high-stability. The biomechanical performance for two types of AVI was analyzed and compared under different loading conditions by finite element method. These implants were manufactured via selective laser melting technology and evaluated via compressive testing. Results showed the maximum Mises stress of the optimized implant under various load cases were about 41.5% of that of the trussed implant, and below fatigue strength of 3D printed titanium materials. The optimized implant was about 2 times to trussed implant in term of the maximum compression load and compression stiffness to per unit mass, which indicated the optimized implant can meet the safety requirement. Finally, the optimized implant has been used in clinical practice and good short-term clinical outcomes were achieved. Therefore, the novel developed method provides a favorable guarantee for the design of 3D printed multi-segment artificial vertebral implants.
Collapse
Affiliation(s)
- Jianfeng Kang
- Jihua Laboratory, Foshan, Guangdong, China; State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaan Xi, China
| | - Enchun Dong
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaan Xi, China
| | - Xiangdong Li
- Department of Orthopedics, Xijing Hospital, Air Force Medical University of PLA, Xi'an, Shaan Xi, China
| | - Zheng Guo
- Department of Orthopedics, Xijing Hospital, Air Force Medical University of PLA, Xi'an, Shaan Xi, China
| | - Lei Shi
- Department of Orthopedics, Xijing Hospital, Air Force Medical University of PLA, Xi'an, Shaan Xi, China
| | - Dichen Li
- Jihua Laboratory, Foshan, Guangdong, China; State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaan Xi, China; Guangdong Xi'an Jiaotong University Academy, Guangdong, China.
| | - Ling Wang
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaan Xi, China.
| |
Collapse
|
20
|
Bondarenko S, Filipenko V, Karpinsky M, Karpinska O, Ivanov G, Maltseva V, Badnaoui AA, Schwarzkopf R. Osseointegration of porous titanium and tantalum implants in ovariectomized rabbits: A biomechanical study. World J Orthop 2021; 12:214-222. [PMID: 33959485 PMCID: PMC8082506 DOI: 10.5312/wjo.v12.i4.214] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 02/01/2021] [Accepted: 03/11/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Today, biological fixation of uncemented press-fit acetabular components plays an important role in total hip arthroplasty. Long-term stable fixation of these implants depends on the osseointegration of the acetabular cup bone tissue into the acetabular cup implant, and their ability to withstand functional loads.
AIM To compare the strength of bone-implant osseointegration of four types of porous metal implants in normal and osteoporotic bone in rabbits.
METHODS The study was performed in 50 female California rabbits divided into non-ovariectomized (non-OVX) and ovariectomized groups (OVX) at 6 mo of age. Rabbits were sacrificed 8 wk after the implantation of four biomaterials [TTM, CONCELOC, Zimmer Biomet's Trabecular Metal (TANTALUM), and ATLANT] in a 5-mm diameter defect created in the left femur. A biomechanical evaluation of the femur was carried out by testing implant breakout force. The force was gradually increased until complete detachment of the implant from the bone occurred.
RESULTS The breakout force needed for implant detachment was significantly higher in the non-OVX group, compared with the OVX group for all implants (TANTALUM, 194.7 ± 6.1 N vs 181.3 ± 2.8 N; P = 0.005; CONCELOC, 190.8 ± 3.6 N vs 180.9 ± 6.6 N; P = 0.019; TTM, 186.3 ± 1.8 N vs 172.0 N ± 11.0 N; P = 0.043; and ATLANT, 104.9 ± 7.0 N vs 78.9 N ± 4.5 N; P = 0.001). In the OVX group, The breakout forces in TANTALUM, TTM, and CONCELOC did not differ significantly (P = 0.066). The breakout force for ATLANT in the OVX group was lower by a factor of 2.3 compared with TANTALUM and CONCELOC, and by 2.2 compared with TTM (P = 0.001). In the non-OVX group, the breakout force for ATLANT was significantly different from all other implants, with a reduction in fixation strength by a factor of 1.9 (P = 0.001).
CONCLUSION TANTALUM, TTM, and CONCELOC had equal bone-implant osseointegration in healthy and in osteoporotic bone. ATLANT had significantly decreased osseointegration (P = 0.001) in healthy and in osteoporotic bone.
Collapse
Affiliation(s)
- Stanislav Bondarenko
- Department of Joint Pathology, Sytenko Institute of Spine and Joint Pathology, Kharkiv 61124, Ukraine
| | - Volodymyr Filipenko
- Department of Joint Pathology, Sytenko Institute of Spine and Joint Pathology, Kharkiv 61124, Ukraine
| | - Michael Karpinsky
- Department of Biomechanics, Sytenko Institute of Spine and Joint Pathology, Kharkiv 61124, Ukraine
| | - Olena Karpinska
- Department of Biomechanics, Sytenko Institute of Spine and Joint Pathology, Kharkiv 61124, Ukraine
| | - Gennadiy Ivanov
- Department of Experimental Pathology, Sytenko Institute of Spine and Joint Pathology, Kharkiv 61124, Ukraine
| | - Valentyna Maltseva
- Morphology of Connective Tissue Department, Sytenko Institute of Spine and Joint Pathology, Kharkiv 61124, Ukraine
| | - Ahmed Amine Badnaoui
- Department of Joint Pathology, Sytenko Institute of Spine and Joint Pathology, Kharkiv 61124, Ukraine
| | - Ran Schwarzkopf
- Department of Orthopedic Surgery, NYU Langone Orthopedic Hospital, Hospital for Joint Diseases, New York, NY 10003, United States
| |
Collapse
|
21
|
Wang S, Leng H, Tian Y, Xu N, Liu Z. A novel 3D-printed locking cage for anterior atlantoaxial fixation and fusion: case report and in vitro biomechanical evaluation. BMC Musculoskelet Disord 2021; 22:121. [PMID: 33514363 PMCID: PMC7844893 DOI: 10.1186/s12891-021-03987-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 01/19/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Treatment of atlantoaxial dislocation is aimed at reduction and stabilization of the atlantoaxial joint. 3D printing refers to a process where additive manufacturing is achieved under precise computer control. Literature on its utilization in anterior atlantoaxial fixation and fusion is rare. This study is the first report on a 3D-printed locking cage used in the anterior procedure for atlantoaxial dislocation. METHODS A middle-aged male in his 40s presented with weakness and numbness of his extremities for 3 years and could only walk slowly with assistance. Imaging studies revealed severe anterior migration of C1, irreducible atlantoaxial dislocation, and severe cervical-medullary compression. A preoperative plan consisting of trans-oral soft tissue release and fixation using tailor-designed 3D-printed cages was devised. Following fluoroscopic confirmation of reduction of the atlantoaxial joints, two customized 3D-printed cages made of titanium alloy were inserted into the bilateral facet joints, which were then locked by six screws into the lateral masses of C1 and C2. The microstructure of the inserted cages was optimized for improved biomechanical stability and enhanced osseo-integration, without the need for bone grafting. In addition, a biomechanical test was performed on seven human cadaveric specimens comparing the novel implant with the conventional C1 lateral mass-C2 pedicle screw construct in three modes of motion (flexion-extension, lateral bending, axial rotation). RESULTS Improvement of neurologic function in the patient was evident immediately after surgery. He was able to walk independently 1 month post-operatively. At the 12-month follow-up, coronal reconstruction of CT demonstrated properly-positioned 3D-printed cages, evidence of osseo-integration at the bone-implant interface, and no subsidence or displacement of the implant. Eighteen months out of surgery, the mJOA score improved to 15, and lateral X-ray confirmed reduction of atlanto-axial dislocation. Additionally, the new construct provided strong fixation comparable to that conferred by conventional constructs as there was no significant difference observed between the two groups in all three directions of motion. CONCLUSIONS The novel implant represents a new option in the treatment of irreducible atlantoaxial dislocation. It can provide strong anterior support for solid fixation and fusion with a low profile and a microstructure that obviates the need for bone grafting.
Collapse
Affiliation(s)
- Shenglin Wang
- Department of Orthopaedics, Peking University Third Hospital, Beijing, People's Republic of China
| | - Huijie Leng
- Department of Orthopaedics, Peking University Third Hospital, Beijing, People's Republic of China
| | - Yinglun Tian
- Department of Orthopaedics, Peking University Third Hospital, Beijing, People's Republic of China
| | - Nanfang Xu
- Department of Orthopaedics, Peking University Third Hospital, Beijing, People's Republic of China
| | - Zhongjun Liu
- Department of Orthopaedics, Peking University Third Hospital, Beijing, People's Republic of China.
| |
Collapse
|
22
|
Brogini S, Sartori M, Giavaresi G, Cremascoli P, Alemani F, Bellini D, Martini L, Maglio M, Pagani S, Fini M. Osseointegration of additive manufacturing Ti-6Al-4V and Co-Cr-Mo alloys, with and without surface functionalization with hydroxyapatite and type I collagen. J Mech Behav Biomed Mater 2020; 115:104262. [PMID: 33321396 DOI: 10.1016/j.jmbbm.2020.104262] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 11/24/2020] [Accepted: 12/08/2020] [Indexed: 11/24/2022]
Abstract
The introduction of additive manufacturing (AM) technologies has profoundly revolutionized the implant manufacturing industry, with a particularly significant impact on the field of orthopedics. Electron Beam Melting (EBM) and Direct Metal Laser Sintering (DMLS) represents AM fabrication techniques with a pivotal role in the realization of complex and innovative structure starting from virtual 3D model data. In this study, Ti-6Al-4V and Co-Cr-Mo materials, developed by EBM (Ti-POR) and DMLS (Co-POR) techniques, respectively, with hydroxyapatite (Ti-POR + HA; Co-POR + HA) and type I collagen (Ti-POR-COLL; Co-POR-COLL) coatings, were implanted into lateral femoral condyles of rabbits. Osseointegration process was investigated by histological, histomorphometrical and microhardness evaluations at 4 and 12 weeks after implantation. Both Ti-6Al-4V and Co-Cr-Mo implants, with or without HA and COLL coatings, demonstrated good biocompatibility. As expected, HA coating hastened bone-to-implant contact (BIC) process, while collagen did not significantly improved the osseointegration process in comparison to controls. Regarding newly trabecular bone formation (B.Ar/T.Ar), Co-POR presented the highest values, significantly different from those of Co-POR-COLL. Over time, an increase of BIC parameter and a decrease of B.Ar/T.Ar were detected. Higher mineral apposition rate was observed for Ti-POR and Co-POR in comparison to Ti-POR-COLL and Co-POR-COLL, respectively, at 12 weeks. The same behavior was found for bone formation rate between Co-POR and Co-POR-COLL at 12 weeks. In conclusion, the AM materials guarantee a good osseointegration and provide a suitable environment for bone regeneration with the peculiarity of allowing personalized and patient-specific needs customization to further improve the long-term clinical outcomes.
Collapse
Affiliation(s)
- Silvia Brogini
- IRCCS Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Bologna, Italy
| | - Maria Sartori
- IRCCS Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Bologna, Italy.
| | - Gianluca Giavaresi
- IRCCS Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Bologna, Italy
| | | | | | | | - Lucia Martini
- IRCCS Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Bologna, Italy
| | - Melania Maglio
- IRCCS Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Bologna, Italy
| | - Stefania Pagani
- IRCCS Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Bologna, Italy
| | - Milena Fini
- IRCCS Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Bologna, Italy
| |
Collapse
|
23
|
Wei F, Xu N, Li Z, Cai H, Zhou F, Yang J, Yu M, Liu X, Sun Y, Zhang K, Pan S, Wu F, Liu Z. A prospective randomized cohort study on 3D-printed artificial vertebral body in single-level anterior cervical corpectomy for cervical spondylotic myelopathy. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:1070. [PMID: 33145289 PMCID: PMC7575998 DOI: 10.21037/atm-19-4719] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background This was a prospective randomized cohort study aiming at examining the safety and efficacy of artificial vertebral body (AVB) fabricated by electron beam melting (EBM) in comparison to conventional titanium mesh cage (TMC) used in single-level anterior cervical corpectomy and fusion (SL-ACCF). Methods Forty patients with cervical spondylotic myelopathy (CSM) underwent SL-ACCF using either the EBM-AVB or the TMC. Patients were evaluated for their demographics, radiological characteristics, neurologic function [using the Japanese Orthopaedic Association (JOA) scale], and health-related quality-of-life (HRQoL) aspects [using the Short Form 36 (SF-36)] before and after the surgery and comparison was made between the two groups both at baseline and the last follow-up. The Student t-text, paired-sample t-text, and Fisher's exact test were used when appropriate to detect any statistical significance at the level of α=0.05. Results Post-operative recovery was uneventful for all patients and no revision surgery was required. There were no significant differences between the EBM-AVB group and the TMC group at baseline. Patients in both groups demonstrated significant improvement in cervical alignment, JOA score, and SF-36 score after the surgery. Six months post-operatively, patients in the EBM-AVB group were found to have significantly less loss of fusion height and lower incidence for severe implant subsidence compared with the TMC group. Patients in the two groups were comparable at the last follow-up regarding their rate of fusion, cervical alignment, JOA recovery rate, SF-36 score, and by Odom's criteria. Conclusions For CSM patients undergoing SL-ACCF, the EBM-AVB group demonstrated comparable outcomes regarding patient cervical alignment, neurologic function, and HRQoL in comparison with the TMC group. Furthermore, the use of EBM-AVB was associated with decreased loss of the height of the fusion mass and a lower rate for severe implant subsidence.
Collapse
Affiliation(s)
- Feng Wei
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Nanfang Xu
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Zihe Li
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Hong Cai
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Feifei Zhou
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Jun Yang
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Miao Yu
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Xiaoguang Liu
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Yu Sun
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Ke Zhang
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Shengfa Pan
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Fengliang Wu
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Zhongjun Liu
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| |
Collapse
|
24
|
The Use of Simulated Body Fluid (SBF) for Assessing Materials Bioactivity in the Context of Tissue Engineering: Review and Challenges. Biomimetics (Basel) 2020; 5:biomimetics5040057. [PMID: 33138246 PMCID: PMC7709622 DOI: 10.3390/biomimetics5040057] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 10/22/2020] [Accepted: 10/26/2020] [Indexed: 01/16/2023] Open
Abstract
Some special implantable materials are defined as “bioactive” if they can bond to living bone, forming a tight and chemically-stable interface. This property, which is inherent to some glass compositions, or can be induced by applying appropriate surface treatments on otherwise bio-inert metals, can be evaluated in vitro by immersion studies in simulated body fluid (SBF), mimicking the composition of human plasma. As a result, apatite coating may form on the material surface, and the presence of this bone-like “biomimetic skin” is considered predictive of bone-bonding ability in vivo. This review article summarizes the story and evolution of in vitro bioactivity testing methods using SBF, highlighting the influence of testing parameters (e.g., formulation and circulation of the solution) and material-related parameters (e.g., composition, geometry, texture). Suggestions for future methodological refinements are also provided at the end of the paper.
Collapse
|
25
|
Evaluation of the bone morphology around four types of porous metal implants placed in distal femur of ovariectomized rats. J Orthop Surg Res 2020; 15:296. [PMID: 32746931 PMCID: PMC7398357 DOI: 10.1186/s13018-020-01822-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Accepted: 07/28/2020] [Indexed: 12/13/2022] Open
Abstract
Background To compare structural features of the femoral bone of ovariectomized and non-ovariectomized rats after implantation of porous materials (TANTALUM, CONCELOC, TTM, ATLANT). Methods Experiments were carried out on 56 white laboratory female rats aged 6 months. Rats were randomly assigned into groups: sham-operated control group (SH) or ovariectomy group (OVX). Four different commercial implant materials (TTM, CONCELOC, TANTALUM, ATLANT) were placed into the defects (diameter 2.5 mm, depth 3.0 mm) in the distal metaphysis of femurs. Rats were sacrificed 45 days after surgery. Histological study was performed and the percentage of the bone area (BA%) around the implant at a distance of 500 μm in the cancellous area was measured. Results Formation of mature bone tissue of varying degrees around all of the implants was detected. In OVX rats cancellous bone defect zone was characterized by a high density of osteocytes on the surface. In the SH group, no differences in BA% among implant materials were found. In OVX rats, the BA% around ATLANT implants was 1.5-time less (p = 0.002) than around TANTALUM. The BA% around the rest of the materials was not statistically different. Conclusions Bone formation around the studied porous titanium and tantalum materials in the osteoporosis model was lower than in normal bone. There were differences in bone formation around the different materials in the osteoporosis model, while in the normal bone model, these differences were absent.
Collapse
|
26
|
Hou G, Liu B, Tian Y, Liu Z, Zhou F, Ji H, Zhang Z, Guo Y, Lv Y, Yang Z, Wen P, Zheng Y, Cheng Y. An innovative strategy to treat large metaphyseal segmental femoral bone defect using customized design and 3D printed micro-porous prosthesis: a prospective clinical study. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2020; 31:66. [PMID: 32696168 DOI: 10.1007/s10856-020-06406-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Accepted: 07/12/2020] [Indexed: 06/11/2023]
Abstract
Five patients with segmental irregular-shaped bone defect of the femur were recruited in this study from 2017.12 to 2018.11. All patients were treated by customized design and 3D printed micro-porous prosthesis. And the procedure was divided into stages: radical debridement and temporary fixation (the first stage); the membrane formation and virtual surgery (intervening period for 6-8 weeks); definite reconstruction the defects (the second stage). Routine clinical follow-up and radiographic evaluation were done to assess bone incorporation and complications of internal fixation. The weight-bearing time and the joint function of the patients were recorded. The patients were followed up for an average of 16.4 months. The average length of bone defect and the distal residual bone was 12 cm and 6.5 cm. The average time of partial weight-bearing and full weight-bearing was 12.7 days and 2.6 months. X-ray demonstrated good osseous integration of the implant/bone interface. No complications occurred such as implant loosening, subsidence, loss of correction and infection. At the last follow-up, Harris score of hip joint was excellent in 2 cases, good in 2 cases, fair in 1 case; HSS score of knee joint was good in 4 cases, middle in 1 case. From our study, we concluded that meticulous customized design 3D printed micro-porous prosthesis combined with intramedullary nail may be a promising and an alternative strategy to treat metaphyseal segmental irregular-shaped femoral bone defect, especially for cases with massive juxta-articular bone loss.
Collapse
Affiliation(s)
- Guojin Hou
- Department of Orthopaedic Surgery, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
| | - Bingchuan Liu
- Department of Orthopaedic Surgery, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
| | - Yun Tian
- Department of Orthopaedic Surgery, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China.
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China.
| | - Zhongjun Liu
- Department of Orthopaedic Surgery, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
| | - Fang Zhou
- Department of Orthopaedic Surgery, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
| | - Hongquan Ji
- Department of Orthopaedic Surgery, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
| | - Zhishan Zhang
- Department of Orthopaedic Surgery, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
| | - Yan Guo
- Department of Orthopaedic Surgery, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
| | - Yang Lv
- Department of Orthopaedic Surgery, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
| | - Zhongwei Yang
- Department of Orthopaedic Surgery, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, No 49, North Garden Rd, HaiDian District, 100191, Beijing, China
| | - Peng Wen
- Tsinghua University, 100084, Beijing, China
| | | | - Yan Cheng
- Peking University, 100871, Beijing, China
| |
Collapse
|
27
|
Zhang Y, Li C, Li L, Sun Y, Li Z, Mei Y, Feng X. Design a novel integrated screw for minimally invasive atlantoaxial anterior transarticular screw fixation: a finite element analysis. J Orthop Surg Res 2020; 15:244. [PMID: 32631369 PMCID: PMC7339419 DOI: 10.1186/s13018-020-01764-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Accepted: 06/26/2020] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To design a new type of screw for minimally invasive atlantoaxial anterior transarticular screw (AATS) fixation with a diameter that is significantly thicker than that of traditional screws, threaded structures at both ends, and a porous metal structure in the middle. The use of a porous metal structure can effectively promote bone fusion and compensate for the disadvantages of traditional AATSs in terms of insufficient fixation strength and difficulty of bone fusion. The biomechanical stability of this screw was verified through finite element analysis. This instrument may provide a new surgical option for the treatment of atlantoaxial disorders. METHODS According to the surgical procedure, the new type of AATS was placed in a three-dimensional atlantoaxial model to determine the setting of relevant parameters such as the diameter, length, and thread to porous metal ratio of the structure. According to the results of measurement, the feasibility and safety of the new AATS were verified, and a representative finite element model of the upper cervical vertebrae was chosen to establish, and the validity of the model was verified. Then, finite element-based biomechanical analysis was performed using three models, i.e., atlantoaxial posterior pedicle screw fixation, traditional atlantoaxial AATS fixation, and atlantoaxial AATS fixation with the new type of screw, and the biomechanical effectiveness of the novel AATS was verified. RESULTS By measuring the atlantoaxial parameters, the atlantoaxial CT data of the representative 30-year-old normal adult male were selected to create a personalized 3D printing AATS screw. In this case, the design parameters of the new screw were determined as follows: diameter, 6 mm; length of the head thread structure, 10 mm; length of the middle porous metal structure, 8 mm (a middle porous structure containing an annular cylinder ); length of the tail thread structure, 8 mm; and total length, 26 mm. Applying the same load conditions to the atlantoaxial complex along different directions in the established finite element models of the three types of atlantoaxial fusion modes, the immediate stability of the new AATS is similar with Atlantoaxial posterior pedicle screw fixation.They are both superior to traditional atlantoaxial anterior screw fixation.The maximum local stress on the screw head in the atlantoaxial anterior surgery was less than those of traditional atlantoaxial anterior surgery. CONCLUSIONS By measuring relevant atlantoaxial data, we found that screws with a larger diameter can be used in AATS surgery, and the new AATS can make full use of the atlantoaxial lateral mass space and increase the stability of fixation. The finite element analysis and verification revealed that the biomechanical stability of the new AATS was superior to the AATS used in traditional atlantoaxial AATS fixation. The porous metal structure of the new AATS may promote fusion between atlantoaxial joints and allow more effective bone fusion in the minimally invasive anterior approach surgery.
Collapse
Affiliation(s)
- Yingkai Zhang
- Department of Orthopaedic Surgery, Shengjing Hospital of China Medical University, Sanhao Road 36, Shenyang City, 110001, Liaoning Province, People's Republic of China
| | - Cheng Li
- Department of Orthopaedic Surgery, Shengjing Hospital of China Medical University, Sanhao Road 36, Shenyang City, 110001, Liaoning Province, People's Republic of China
| | - Lei Li
- Department of Orthopaedic Surgery, Shengjing Hospital of China Medical University, Sanhao Road 36, Shenyang City, 110001, Liaoning Province, People's Republic of China.
| | - Yanyan Sun
- Shandong Weigao Orthopaedic Device co., Ltd., Weihai, 264300, People's Republic of China
| | - Zeqing Li
- Department of Orthopaedic Surgery, Shengjing Hospital of China Medical University, Sanhao Road 36, Shenyang City, 110001, Liaoning Province, People's Republic of China
| | - Yunli Mei
- Department of Orthopaedic Surgery, Shengjing Hospital of China Medical University, Sanhao Road 36, Shenyang City, 110001, Liaoning Province, People's Republic of China
| | - Xinyuan Feng
- Department of Orthopaedic Surgery, Shengjing Hospital of China Medical University, Sanhao Road 36, Shenyang City, 110001, Liaoning Province, People's Republic of China
| |
Collapse
|
28
|
Abstract
Additive manufacturing (AM) processes have undergone significant progress in recent years, having been implemented in sectors as diverse as automotive, aerospace, electrical component manufacturing, etc. In the medical sector, different devices are printed, such as implants, surgical guides, scaffolds, tissue engineering, etc. Although nowadays some implants are made of plastics or ceramics, metals have been traditionally employed in their manufacture. However, metallic implants obtained by traditional methods such as machining have the drawbacks that they are manufactured in standard sizes, and that it is difficult to obtain porous structures that favor fixation of the prostheses by means of osseointegration. The present paper presents an overview of the use of AM technologies to manufacture metallic implants. First, the different technologies used for metals are presented, focusing on the main advantages and drawbacks of each one of them. Considered technologies are binder jetting (BJ), selective laser melting (SLM), electron beam melting (EBM), direct energy deposition (DED), and material extrusion by fused filament fabrication (FFF) with metal filled polymers. Then, different metals used in the medical sector are listed, and their properties are summarized, with the focus on Ti and CoCr alloys. They are divided into two groups, namely ferrous and non-ferrous alloys. Finally, the state-of-art about the manufacture of metallic implants with AM technologies is summarized. The present paper will help to explain the latest progress in the application of AM processes to the manufacture of implants.
Collapse
|
29
|
|
30
|
Abstract
Metallic additive manufacturing, a process by which metal structures are created in a layered fashion, is poised to revolutionize orthopaedic implants and instruments. It allows for the design and manufacture of devices, which not only macroscopically more closely match patient-specific anatomy but also have improved microscopic detail for more rapid and durable host integration. In addition, additive manufacturing-designed implants have improved biomechanical properties and fixation systems allowing use in areas where current implants are not well suited. This review provides an overview of the technology and both its current and future use in orthopaedic surgery.
Collapse
|
31
|
Wei F, Li Z, Liu Z, Liu X, Jiang L, Yu M, Xu N, Wu F, Dang L, Zhou H, Li Z, Cai H. Upper cervical spine reconstruction using customized 3D-printed vertebral body in 9 patients with primary tumors involving C2. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:332. [PMID: 32355776 PMCID: PMC7186708 DOI: 10.21037/atm.2020.03.32] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/05/2022]
Abstract
Background Reconstruction following resection of the primary tumors of the upper cervical spine is challenging, and conventional internal implants develop complications in this region. 3D printing, also known as additive manufacturing, can produce patient-specific porous implants in a particular shape for bone defect reconstruction. This study aimed to describe the clinical outcomes of upper cervical spine reconstruction using customized 3D-printed vertebral body in 9 patients with primary tumors involving C2. Methods Patients with primary tumors involving C2 who were treated in our institution between July 2014 and November 2018 were enrolled. A two-stage intralesional spondylectomy was performed using the posterior-anterior approach. Anterior reconstruction was accomplished using a customized 3D-printed vertebral body, which was fabricated by successive layering of melted titanium alloy powder using electron beam melting. No bone graft was used. Results Nine patients (2 males and 7 females) were included in the study with a mean age of 31.4 years (12 to 59 years). Seven patients demonstrated tumors located in C2 and 2 showed involvement of C2 and C3. During a mean follow-up of 28.6 months (range, 12–42 months), 1 patient died of systemic metastasis and 1 had local tumor recurrence, the other 7 patients were alive and functional in their daily living until the last follow-up without evidence of disease. The 3D-printed vertebral bodies were all stable with no sign of displacement or subsidence, evidence of implant osseointegration was observed on the imaging studies. For the posterior instrumentation systems, no screw loosening or rod breakage was found. Conclusions Spinal reconstruction in the upper cervical region using customized 3D-printed vertebral body is reliable. The tailored shape matching with the contact surfaces and the porous structure conductive to osseointegration provide both short- and long-term stability to the implant.
Collapse
Affiliation(s)
- Feng Wei
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Zhehuang Li
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Zhongjun Liu
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Xiaoguang Liu
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Liang Jiang
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Miao Yu
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Nanfang Xu
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Fengliang Wu
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Lei Dang
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Hua Zhou
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Zihe Li
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Hong Cai
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| |
Collapse
|
32
|
Sun Y, Xia Y, Zhang X, Li W, Xing Q. An innovative occluder for cardiac defect: 3D printing and a biocompatibility research based on self-developed bioabsorbable material-LA-GA-TMC. J Biomed Mater Res B Appl Biomater 2020; 108:2108-2118. [PMID: 31961054 DOI: 10.1002/jbm.b.34550] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 12/09/2019] [Accepted: 12/20/2019] [Indexed: 11/08/2022]
Abstract
This study adopted the latest self-developed bioabsorbable material lactide-glycolide-1,3-trimethylene carbonate (LA-GA-TMC) and applied the three-dimensional (3D) printing technique to manufacture the occluder for cardiac septal defects, so as to realize the individualized treatment of cardiac septal defects. At the same time, its biosafety was evaluated, with an aim to establish foundation for futural large-scale animal experiment and clinical trial. The traditional "one-pot synthesis" was modified, and the "two-step synthesis method" was utilized to synthesize the LA-GA-TMC terpolymer at the lactide: glycolide: trimethylene carbonate ratio of 6:1:1.7. Afterward, the synthesized terpolymer was used as the raw material to fabricate the occluder model via using 3D printing technique. Then, its biocompatibility was comprehensively evaluated through cytocompatibility, blood compatibility, and histocompatibility. The occluder made from LA-GA-TMC 3D printing had favorable ductility and recoverability; besides, it possessed the temperature-control feature, and the relative cell proliferation rates in extract liquids at various concentrations were all >70%, suggesting that it had favorable cytocompatibility. Moreover, hemolytic experiment revealed that its hemolytic rate was <5%, dynamic blood coagulation experiment demonstrated that the sample material moderately activated the blood coagulation, and the above findings suggested that it had good blood compatibility. In addition, implanting experiment in vivo revealed that its histocompatibility was superior to the traditional nitinol and the emerging poly-l-lactic acid. It is completely feasible to manufacture the cardiac septal defects occluder based on the novel absorbable material LA-GA-TMC, which has favorable biocompatibility, through 3D printing technique and it possesses broad prospects in large-scale animal experiment and clinical trial.
Collapse
Affiliation(s)
- Yiming Sun
- Medical College, Qingdao University, Qingdao, China
| | - Yinghui Xia
- Affiliated Women and Children's Hospital of Qingdao University, Cardiac Center, Qingdao University, Qingdao, China
| | - Xingjian Zhang
- Cardiovascular Surgery Department, Jinan No. 4 Hospital, Jinan, China
| | - Wenjing Li
- Medical College, Qingdao University, Qingdao, China
| | - Quansheng Xing
- Affiliated Women and Children's Hospital of Qingdao University, Cardiac Center, Qingdao University, Qingdao, China
| |
Collapse
|
33
|
Zhang W, Sun C, Zhu J, Zhang W, Leng H, Song C. 3D printed porous titanium cages filled with simvastatin hydrogel promotes bone ingrowth and spinal fusion in rhesus macaques. Biomater Sci 2020; 8:4147-4156. [PMID: 32496502 DOI: 10.1039/d0bm00361a] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Sustainable release of simvastatin from poloxamer 407 hydrogel in 3D-printed porous Ti6Al4V for spinal fusion in rhesus macaques.
Collapse
Affiliation(s)
- Wen Zhang
- Department of Spine Surgery
- Shandong Provincial Hospital Affiliated to Shandong First Medical University
- Shandong Provincial Hospital Affiliated to Shandong University
- Jinan
- China
| | - Chuiguo Sun
- Department of Orthopaedics
- Peking University Third Hospital
- Beijing
- China
| | - Junxiong Zhu
- Department of Orthopaedics
- Peking University Third Hospital
- Beijing
- China
- Beijing Key Laboratory of Spinal Diseases
| | - Weifang Zhang
- Department of Nuclear Medicine
- Peking University Third Hospital
- Beijing
- China
| | - Huijie Leng
- Department of Orthopaedics
- Peking University Third Hospital
- Beijing
- China
- Beijing Key Laboratory of Spinal Diseases
| | - Chunli Song
- Department of Orthopaedics
- Peking University Third Hospital
- Beijing
- China
- Beijing Key Laboratory of Spinal Diseases
| |
Collapse
|
34
|
Zhang T, Wei Q, Fan D, Liu X, Li W, Song C, Tian Y, Cai H, Zheng Y, Liu Z. Improved osseointegration with rhBMP-2 intraoperatively loaded in a specifically designed 3D-printed porous Ti6Al4V vertebral implant. Biomater Sci 2019; 8:1279-1289. [PMID: 31867583 DOI: 10.1039/c9bm01655d] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Three-dimensional (3D)-printed porous Ti6Al4V implants are commonly used for reconstructing bone defects in the treatment of orthopaedic diseases owing to their excellent osteoconduction. However, to achieve improved therapeutic outcomes, the osteoinduction of these implants requires further improvement. The aim of this study was to investigate the combined use of recombinant human BMP-2 (rhBMP-2) with a 3D-printed artificial vertebral implant (3D-AVI) to improve the osteoinduction. Eight male Small Tail Han sheep underwent cervical corpectomy, and 3D-AVIs with or without loaded rhBMP-2 in cavities designed at the center were implanted to treat the cervical defect. Radiographic, micro-computed tomography, fluorescence labelling, and histological examination revealed that the osseointegration efficiency of the rhBMP-2 group was significantly higher than that of the blank control group. The biomechanical test results suggested that rhBMP-2 reduced the range of motion of the cervical spine and provided a more stable implant. Fluorescence observations revealed that the bone tissue grew from the periphery to the center of the 3D-AVIs, first growing into the pore space and then interlocking with the Ti6Al4V implant surface. Therefore, we successfully improved osseointegration of the 3D-AVI by loading rhBMP-2 into the cavity designed at the center of the Ti6Al4V implant, realizing earlier and more stable fixation of implants postoperatively in a simple manner. These benefits of rhBMP-2 are expected to expand the application range and reliability of 3D-printed porous Ti6Al4V implants and improve their therapeutic efficacy.
Collapse
Affiliation(s)
- Teng Zhang
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, People's Republic of China.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
35
|
3D printing and biocompatibility study of a new biodegradable occluder for cardiac defect. J Cardiol 2019; 74:182-188. [DOI: 10.1016/j.jjcc.2019.02.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Revised: 12/31/2018] [Accepted: 02/02/2019] [Indexed: 11/19/2022]
|
36
|
Zhang RF, Wang PY, Ming Yang, Dong X, Liu X, Sang Y, Tong A. Retracted Article: Application of 3D printing technology in orthopedic medical implant - Spinal surgery as an example. Int J Bioprint 2019; 5:168. [PMID: 32782982 PMCID: PMC7415852 DOI: 10.18063/ijb.v5i2.168] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Accepted: 04/04/2019] [Indexed: 01/13/2023] Open
Abstract
Additive manufacturing has been used in complex spinal surgical planning since the 1990s and is now increasingly utilized to produce surgical guides, templates, and more recently customized implants. Surgeons report beneficial impacts using additively manufactured biomodels as pre-operative planning aids as it generally provides a better representation of the patient's anatomy than on-screen viewing of computed tomography (CT) or magnetic resonance imaging (MRI). Furthermore, it has proven to be very beneficial in surgical training and in explaining complex deformity and surgical plans to patients/parents. This paper reviews the historical perspective, current use, and future directions in using additive manufacturing in complex spinal surgery cases. This review reflects the authors' opinion of where the field is moving in light of the current literature. Despite the reported benefits of additive manufacturing for surgical planning in recent years, it remains a high niche market. This review raises the question as to why the use of this technology has not progressed more rapidly despite the reported advantages - decreased operating time, decreased radiation exposure to patients intraoperatively, improved overall surgical outcomes, pre-operative implant selection, as well as being an excellent communication aid for all medical and surgical team members. Increasingly, the greatest benefits of additive manufacturing technology in spinal surgery are custom-designed drill guides, templates for pedicle screw placement, and customized patient-specific implants. In view of these applications, additive manufacturing technology could potentially revolutionize health care in the near future.
Collapse
Affiliation(s)
- Rong Feng Zhang
- Department of Orthopaedics, Shandong Hospital of People's Liberation Army, 89 Hy, Weifang, Shandong Province, Republic of China
| | - Peng Yun Wang
- Department of Spine Surgery, Central Hospital, Zibo, Zhangdian, Shandong Province, China
| | - Ming Yang
- Traditional Chinese Medicine Hospital, Dongying, Hekou, Shandong Province, China
| | - Xuebo Dong
- Department of Orthopaedics, Shandong Hospital of People's Liberation Army, 89 Hy, Weifang, Shandong Province, Republic of China
| | - Xue Liu
- Department of Orthopaedics, Shandong Hospital of People's Liberation Army, 89 Hy, Weifang, Shandong Province, Republic of China
| | - Yiguang Sang
- Qilu Hospital, Shandong University, Shandong, China
| | - An Tong
- Department of Orthopedics, People's Hospital of Yan'an, Qilipu Street, Yan'an, Baota, Shaanxi Province, China
| |
Collapse
|
37
|
A preliminary study of the novel antibiotic-loaded cement computer-aided design-articulating spacer for the treatment of periprosthetic knee infection. J Orthop Surg Res 2019; 14:136. [PMID: 31096988 PMCID: PMC6521453 DOI: 10.1186/s13018-019-1175-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Accepted: 04/29/2019] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND In comparison to static spacers, articulating spacers have been shown to result in a similar infection eradication rate in two-stage revision of periprosthetic knee infections. However, the optimal construct for articulating spacers has not been identified yet. The aim of this study was to present a preliminary result of treatment for periprosthetic knee infection using a novel computer-aided design (CAD)-articulating spacer. METHODS We retrospectively reviewed 32 consecutive cases of chronic periprosthetic knee infection occurring from January 2015 to December 2015. In these cases, we used an antibiotic-loaded, optimized CAD-articulating spacer based on the retrieved knee prosthesis. Evaluation included infection eradication rate, the Hospital of Special Surgery (HSS) knee score, range of motion (ROM), and spacer-related mechanical complications. All cases were regularly followed-up for 2 years minimum. RESULTS Twenty-eight of 32 patients (87.5%) had infection eradication; 18 patients (56.3%) received reimplantation successfully. The mean interval between spacer insertion and reimplantation was 8.8 months (range 4.0-12.5 months). The mean HSS knee score and ROM significantly increased during each interval (p < 0.0001 for both). The mean HSS knee scores were 31.2 (range 20-48) at initial visit, 65.4 (range 60-78.8) at 1 month after spacer insertion, and 84.2 (range 78-90) at 3 months after reimplantation (p < 0.0001). The mean ROM were 72.0° (range 15-100°), 85.6° (range 35-110°), and 102.0° (range 80-122°), respectively (p = 0.002). Two (6.3%) spacer-related mechanical complications occurred. CONCLUSIONS The CAD-articulating spacer in two-staged revision of periprosthetic knee infection significantly controlled infection, improved clinical outcomes, increased ROM, and decreased mechanical complications in the preliminary study. Further larger clinical studies are needed to confirm the findings presented here.
Collapse
|
38
|
Li N, Hu WQ, Xin WQ, Li QF, Tian P. Comparison between porous tantalum metal implants and autograft in anterior cervical discectomy and fusion: a meta-analysis. J Comp Eff Res 2019; 8:511-521. [PMID: 30907632 DOI: 10.2217/cer-2018-0107] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Aim: The objective of this study was to systematically compare the safety and efficacy of porous tantalum metal (TM) implants and autograft in single-level anterior cervical discectomy and fusion. Methods: Potential academic articles were acquired from the Cochrane Library, Medline, PubMed, Embase, Science Direct and other databases. The time range used was from the inception of the electronic databases to March 2018. Gray studies were identified from the references of included literature reports. STATA version 11.0 (Stata Corporation, TX, USA) was used to analyze the pooled data. Results: Four randomized, controlled trials (RCTs) were identified according to the retrieval process. There were significant differences in operation time (mean difference [MD]: -28.846, 95% confidence interval [CI: -47.087, -10.604], p = 0.002) and satisfaction rate (odds ratio [OR]: 2.196, 95% CI: [1.061-4. 546]; p = 0.034). However, no significant difference was detected in blood loss (MD: -73.606, 95% CI: [-217.720, 70.509], p = 0.317), hospital stay (MD: -0.512, 95% CI [-1.082, 0.058]; p = 0.079), fusion rate (OR: 0.497, 95% CI [0.079, 3.115]; p = 0.455), visual analog scale (MD: -0.310, 95% CI [-0.433, -0.186]; p < 0.001) or complication rate (risk difference [RD]: -0.140, 95% CI: [-0.378, 0.099]; p = 0.251). Conclusion: Porous TM implants are equally as effective and safe as autograft in anterior cervical discectomy and fusion processes. In addition, porous TM implants could reduce operation time and improve clinical satisfaction significantly.
Collapse
Affiliation(s)
- Na Li
- Department of Orthopedics, Tianjin Medical University General Hospital, Tianjin, China, 300052
| | - Wen-Qing Hu
- Department of Rehabilitation, Tianjin Medical University General Hospital, Tianjin, China, 300052
| | - Wen-Qiang Xin
- Department of Neurosurgery, Tianjin Medical University General Hospital, Tianjin, China, 30052
| | - Qi-Feng Li
- Department of Neurosurgery, Tianjin Medical University General Hospital, Tianjin, China, 30052
| | - Peng Tian
- Department of Orthopedics, Tianjin Hospital, Tianjin, PR China, 300211
| |
Collapse
|
39
|
Li P, Jiang W, Yan J, Hu K, Han Z, Wang B, Zhao Y, Cui G, Wang Z, Mao K, Wang Y, Cui F. A novel 3D printed cage with microporous structure and in vivo fusion function. J Biomed Mater Res A 2019; 107:1386-1392. [PMID: 30724479 DOI: 10.1002/jbm.a.36652] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Revised: 01/21/2019] [Accepted: 02/04/2019] [Indexed: 01/28/2023]
Affiliation(s)
- Peng Li
- Department of OrthopedicsChinese PLA General Hospital Beijing, 100853 China
| | - Wei Jiang
- Department of OrthopedicsChinese PLA General Hospital Beijing, 100853 China
| | - Jia Yan
- Institute of Printing and Packaging EngineeringBeijing Institute of Graphic Communication Beijing, 102600 China
| | - Kun Hu
- Institute of Printing and Packaging EngineeringBeijing Institute of Graphic Communication Beijing, 102600 China
| | - Zhenchuan Han
- Department of OrthopedicsChinese PLA General Hospital Beijing, 100853 China
| | - Bo Wang
- Department of OrthopedicsChinese PLA General Hospital Beijing, 100853 China
| | - Yongfei Zhao
- Department of OrthopedicsChinese PLA General Hospital Beijing, 100853 China
| | - Geng Cui
- Department of OrthopedicsChinese PLA General Hospital Beijing, 100853 China
| | - Zheng Wang
- Department of OrthopedicsChinese PLA General Hospital Beijing, 100853 China
| | - Keya Mao
- Department of OrthopedicsChinese PLA General Hospital Beijing, 100853 China
| | - Yan Wang
- Department of OrthopedicsChinese PLA General Hospital Beijing, 100853 China
| | - Fuzhai Cui
- Department of Materials Science and EngineeringTsinghua University Beijing, 100084 China
| |
Collapse
|
40
|
Wu Y, Liu D, Zhou Q, Wang L, Li X, Yang X, Zhu X, Zhang K, Song Y, Zhang X. Effect of surface microstructure on the anti-fibrosis/adhesion of hydroxyapatite ceramics in spinal repair of rabbits. J Biomed Mater Res B Appl Biomater 2019; 107:2629-2637. [PMID: 30861641 DOI: 10.1002/jbm.b.34352] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2019] [Revised: 02/13/2019] [Accepted: 02/18/2019] [Indexed: 02/05/2023]
Abstract
Epidural adhesion is a great clinical challenge after laminectomy. In the present study, two types of hydroxyapatite (HA) laminas with distinct surface microstructures were prepared by cold isostatic pressing (CIP) and slip casting (SC) techniques, and investigated to their anti-fibrosis/adhesion effects by in vitro and in vivo evaluations. In contrast with the dense HA-CIP, HA-SC had a large number of micropores on the surface. After cultured on both HA ceramics, human skin fibroblasts presented the obvious senescent feature, and CCN1 gene expression was significantly up-regulated. HA-SC induced higher CCN1 gene expression than HA-CIP. After used for closing the lost vertebral after laminectomy in rabbits, both HA laminas promoted the recovery of the bony structure as well as prevented the hyperplastic fibrous tissue from penetration into the spinal canal area and inhibited the formation of scar-like tissue in laminectomy sites to some extent. Besides, thinner layer of fibrous tissue and smaller gap between the implant surface and paravertebral muscles were found in HA-CIP than HA-SC. Therefore, HA ceramics could have good anti-fibrosis/adhesion effect when used in spinal repair, and the dense HA-CIP could be an ideal choice. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B:2629-2637, 2019.
Collapse
Affiliation(s)
- Yonghao Wu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| | - Dan Liu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| | - Quan Zhou
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu 610041, China
| | - Linnan Wang
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu 610041, China
| | - Xiangfeng Li
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| | - Xi Yang
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu 610041, China
| | - Xiangdong Zhu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| | - Kai Zhang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| | - Yueming Song
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu 610041, China
| | - Xingdong Zhang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| |
Collapse
|
41
|
Wen Z, Lu T, Wang Y, Liang H, Gao Z, He X. Anterior Cervical Corpectomy and Fusion and Anterior Cervical Discectomy and Fusion Using Titanium Mesh Cages for Treatment of Degenerative Cervical Pathologies: A Literature Review. Med Sci Monit 2018; 24:6398-6404. [PMID: 30208015 PMCID: PMC6147051 DOI: 10.12659/msm.910269] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Anterior cervical corpectomy and fusion (ACCF) and anterior cervical discectomy and fusion (ACDF) are 2 effective and safe surgical treatments of degenerative cervical pathologies and are associated with a high percentage of excellent clinical outcomes when a graft or device must be used during the surgery, such as an allograft, autograft, nano-hydroxyapatite/polyamide cages, poly-ether-ether-ketone (PEEK) cages, and titanium mesh cages (TMCs). Although TMCs have been used in cervical surgeries for almost 2 decades, no specific reviews have been performed introducing the state of this material. Thus, in the present review, we discuss the status of using TMCs in anterior cervical surgeries. Studies that tested the usage of TMCs in treating degenerative cervical pathologies were included in this review. The development and progress of TMCs, the biomechanical analysis of TMCs, the radiological and clinical assessment of TMCs, the advantages and disadvantages of using TMCs, and their prospects for future applications as a device of ACCF and ACDF in treating degenerative cervical pathologies are discussed. Studies included in this review showed that TMCs can provide sufficient biomechanical stability. Furthermore, the TMCs used in anterior cervical fusion avoid the donor-site morbidity and achieve a solid bony fusion. However, there are some shortcomings. The structural characteristics and the design of TMCs cause the TMC subsidence rate to remain high, thus resulting in multiple related complications. We believe that due to the virtues of TMCs, they are worthy of application and promotion. However, the structure of TMCs should be further optimized to reduce the TMC subsidence rate and subsidence-related complications, ultimately achieving excellent clinical results.
Collapse
Affiliation(s)
- Zhijing Wen
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Teng Lu
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Yibin Wang
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Hui Liang
- Department of Orthopaedics, Second Affiliated Hospital of Xi'an Jiaotong University, Shanxi xi'an, China (mainland)
| | - Zhengchao Gao
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Xijing He
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| |
Collapse
|
42
|
Ran Q, Yang W, Hu Y, Shen X, Yu Y, Xiang Y, Cai K. Osteogenesis of 3D printed porous Ti6Al4V implants with different pore sizes. J Mech Behav Biomed Mater 2018; 84:1-11. [PMID: 29709846 DOI: 10.1016/j.jmbbm.2018.04.010] [Citation(s) in RCA: 134] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2018] [Revised: 03/21/2018] [Accepted: 04/11/2018] [Indexed: 01/02/2023]
Abstract
Selective laser melting (SLM) is one of the three-dimensional (3D) printing techniques that manufacturing versatile porous scaffolds with precise architectures for potential orthopedic application. To understand how the pore sizes of porous Ti6Al4V scaffolds affect their biological performances, we designed and fabricated porous Ti6Al4V implants with straightforward pore dimensions (500, 700, and 900 µm) via SLM, termed as p500, p700, and p900 respectively. The morphological characteristics of Ti6Al4V scaffolds were assessed showing that the actual pore sizes of these scaffolds were 401 ± 26 µm, 607 ± 24 µm, 801 ± 33 µm, respectively. The mechanical properties of Ti6Al4V scaffolds were also evaluated showing that they were comparable to that of bone tissues. Meanwhile, the effect of pore size on biological responses was systematically investigated in vitro and in vivo. It was verified that 3D printing technique was able to fabricate porous Ti6Al4V implants with proper mechanical properties analogous to human bone. The in vitro results revealed that scaffolds with appropriate pore dimension were conducive to cell adhesion, proliferation and early differentiation. Furthermore, the porous Ti6Al4V scaffolds were implanted into the rabbit femur to investigate bone regeneration performance, the in vivo experiment showed the p700 sample was in favor of bone ingrowth into implant pores and bone-implant fixation stability. Taken together, the biological performance of p700 group with actual pore size of about 600 µm was superior to other two groups. The obtained findings provide basis to individually design and fabricate suitable porous Ti6Al4V with specific geometries for orthopedic application.
Collapse
Affiliation(s)
- Qichun Ran
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044, PR China
| | - Weihu Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044, PR China.
| | - Yan Hu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044, PR China
| | - Xinkun Shen
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044, PR China
| | - Yonglin Yu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044, PR China
| | - Yang Xiang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044, PR China
| | - Kaiyong Cai
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044, PR China.
| |
Collapse
|
43
|
Yang WF, Choi WS, Leung YY, Curtin JP, Du R, Zhang CY, Chen XS, Su YX. Three-dimensional printing of patient-specific surgical plates in head and neck reconstruction: A prospective pilot study. Oral Oncol 2018; 78:31-36. [DOI: 10.1016/j.oraloncology.2018.01.005] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 12/14/2017] [Accepted: 01/09/2018] [Indexed: 10/18/2022]
|
44
|
Cai H, Liu Z, Wei F, Yu M, Xu N, Li Z. 3D Printing in Spine Surgery. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2018; 1093:345-359. [PMID: 30306494 DOI: 10.1007/978-981-13-1396-7_27] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
In the past 5 years, the application of 3D printing technology in the field of spine surgery had obtained enormous and substantial progress. Among which, vertebral skeleton model (including lesion model) printing has been widely used in clinical application due to its relatively simple technology and low cost. It shows practical value and becomes popular as the reference of clinical education, auxiliary diagnosis, communication between doctor and patient, and the planning of surgical approaches as well as the reference of more accurate operation in surgery. On the basis of vertebral skeleton model printing, it can be used to design and make navigation template to guide internal fixation screw, which also obtains some remarkable clinical effects. However, 3D printing technology has a more profound influence on spine surgery. The part with full expectation is undoubtedly the clinical application of 3D printing microporous metal implant and personalized implant as well as the clinical application of 3D printing biological materials in the future.
Collapse
Affiliation(s)
- Hong Cai
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Zhongjun Liu
- Department of Orthopedics, Peking University Third Hospital, Beijing, China.
| | - Feng Wei
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Miao Yu
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Nanfang Xu
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| | - Zihe Li
- Department of Orthopedics, Peking University Third Hospital, Beijing, China
| |
Collapse
|
45
|
Gao C, Peng S, Feng P, Shuai C. Bone biomaterials and interactions with stem cells. Bone Res 2017; 5:17059. [PMID: 29285402 PMCID: PMC5738879 DOI: 10.1038/boneres.2017.59] [Citation(s) in RCA: 334] [Impact Index Per Article: 47.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2017] [Revised: 10/15/2017] [Accepted: 10/23/2017] [Indexed: 12/31/2022] Open
Abstract
Bone biomaterials play a vital role in bone repair by providing the necessary substrate for cell adhesion, proliferation, and differentiation and by modulating cell activity and function. In past decades, extensive efforts have been devoted to developing bone biomaterials with a focus on the following issues: (1) developing ideal biomaterials with a combination of suitable biological and mechanical properties; (2) constructing a cell microenvironment with pores ranging in size from nanoscale to submicro- and microscale; and (3) inducing the oriented differentiation of stem cells for artificial-to-biological transformation. Here we present a comprehensive review of the state of the art of bone biomaterials and their interactions with stem cells. Typical bone biomaterials that have been developed, including bioactive ceramics, biodegradable polymers, and biodegradable metals, are reviewed, with an emphasis on their characteristics and applications. The necessary porous structure of bone biomaterials for the cell microenvironment is discussed, along with the corresponding fabrication methods. Additionally, the promising seed stem cells for bone repair are summarized, and their interaction mechanisms with bone biomaterials are discussed in detail. Special attention has been paid to the signaling pathways involved in the focal adhesion and osteogenic differentiation of stem cells on bone biomaterials. Finally, achievements regarding bone biomaterials are summarized, and future research directions are proposed.
Collapse
Affiliation(s)
- Chengde Gao
- State Key Laboratory of High Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha, China
| | - Shuping Peng
- The Key Laboratory of Carcinogenesis of the Chinese Ministry of Health, Xiangya Hospital, Central South University, Changsha, China
- The Key Laboratory of Carcinogenesis and Cancer Invasion of the Chinese Ministry of Education, Cancer Research Institute, Central South University, Changsha, China
| | - Pei Feng
- State Key Laboratory of High Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha, China
| | - Cijun Shuai
- State Key Laboratory of High Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha, China
- Jiangxi University of Science and Technology, Ganzhou, China
- Key Laboratory of Organ Injury, Aging and Regenerative Medicine of Hunan Province, Xiangya Hospital, Central South University, Changsha, China
| |
Collapse
|
46
|
Three-dimensional printing modeling: application in maxillofacial and hand fractures and resident training. EUROPEAN JOURNAL OF PLASTIC SURGERY 2017. [DOI: 10.1007/s00238-017-1373-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
47
|
Multilevel 3D Printing Implant for Reconstructing Cervical Spine With Metastatic Papillary Thyroid Carcinoma. Spine (Phila Pa 1976) 2017; 42:E1326-E1330. [PMID: 28498291 DOI: 10.1097/brs.0000000000002229] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
UNLABELLED MINI: A 3D printing technology is proposed for reconstructing multilevel cervical spine (C2-C4) after resection of metastatic papillary thyroid carcinoma. The personalized porous implant printed in Ti6AL4V provided excellent physicochemical properties and biological performance, including biocompatibility, osteogenic activity, and bone ingrowth effect. STUDY DESIGN A unique case report. OBJECTIVE A three-dimensional (3D) printing technology is proposed for reconstructing multilevel cervical spine (C2-C4) after resection of metastatic papillary thyroid carcinoma in a middle-age female patient. SUMMARY OF BACKGROUND DATA Papillary thyroid carcinoma is a malignant neoplasm with a relatively favorable prognosis. A metastatic lesion in multilevel cervical spine (C2-C4) destroys neurological functions and causes local instability. Radical excision of the metastasis and reconstruction of the cervical vertebrae sequence conforms with therapeutic principles, whereas the special-shaped multilevel upper-cervical spine requires personalized implants. 3D printing is an additive manufacturing technology that produces personalized products by accurately layering material under digital model control via a computer. Reporting of this recent technology for reconstructing multilevel cervical spine (C2-C4) is rare in the literature. METHODS Anterior-posterior surgery was performed in one stage. Radical resection of the metastatic lesion (C2-C4) and thyroid gland, along with insertion of a personalized implant manufactured by 3D printing technology, were performed to rebuild the cervical spine sequences. The porous implant was printed in Ti6AL4V with perfect physicochemical properties and biological performance, such as biocompatibility and osteogenic activity. Finally, lateral mass screw fixation was performed via a posterior approach. RESULTS Patient neurological function gradually improved after the surgery. The patient received 11/17 on the Japanese Orthopedic Association scale and ambulated with a personalized skull-neck-thorax orthosis on postoperative day 11. She received radioiodine I therapy. The plane x-rays and computed tomography revealed no implant displacement or subsidence at the 12-month follow-up mark. CONCLUSION The presented case substantiates the use of 3D printing technology, which enables the personalization of products to solve unconventional problems in spinal surgery. LEVEL OF EVIDENCE 5.
Collapse
|
48
|
Melancon D, Bagheri ZS, Johnston RB, Liu L, Tanzer M, Pasini D. Mechanical characterization of structurally porous biomaterials built via additive manufacturing: experiments, predictive models, and design maps for load-bearing bone replacement implants. Acta Biomater 2017; 63:350-368. [PMID: 28927929 DOI: 10.1016/j.actbio.2017.09.013] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2017] [Revised: 08/30/2017] [Accepted: 09/12/2017] [Indexed: 11/18/2022]
Abstract
Porous biomaterials can be additively manufactured with micro-architecture tailored to satisfy the stringent mechano-biological requirements imposed by bone replacement implants. In a previous investigation, we introduced structurally porous biomaterials, featuring strength five times stronger than commercially available porous materials, and confirmed their bone ingrowth capability in an in vivo canine model. While encouraging, the manufactured biomaterials showed geometric mismatches between their internal porous architecture and that of its as-designed counterpart, as well as discrepancies between predicted and tested mechanical properties, issues not fully elucidated. In this work, we propose a systematic approach integrating computed tomography, mechanical testing, and statistical analysis of geometric imperfections to generate statistical based numerical models of high-strength additively manufactured porous biomaterials. The method is used to develop morphology and mechanical maps that illustrate the role played by pore size, porosity, strut thickness, and topology on the relations governing their elastic modulus and compressive yield strength. Overall, there are mismatches between the mechanical properties of ideal-geometry models and as-manufactured porous biomaterials with average errors of 49% and 41% respectively for compressive elastic modulus and yield strength. The proposed methodology gives more accurate predictions for the compressive stiffness and the compressive strength properties with a reduction of the average error to 11% and 7.6%. The implications of the results and the methodology here introduced are discussed in the relevant biomechanical and clinical context, with insight that highlights promises and limitations of additively manufactured porous biomaterials for load-bearing bone replacement implants. STATEMENT OF SIGNIFICANCE In this work, we perform mechanical characterization of load-bearing porous biomaterials for bone replacement over their entire design space. Results capture the shift in geometry and mechanical properties between as-designed and as-manufactured biomaterials induced by additive manufacturing. Characterization of this shift is crucial to ensure appropriate manufacturing of bone replacement implants that enable biological fixation through bone ingrowth as well as mechanical property harmonization with the native bone tissue. In addition, we propose a method to include manufacturing imperfections in the numerical models that can reduce the discrepancy between predicted and tested properties. The results give insight into the use of structurally porous biomaterials for the design and additive fabrication of load-bearing implants for bone replacement.
Collapse
Affiliation(s)
- D Melancon
- Mechanical Engineering Department, McGill University, Montreal, Quebec H3G 1A4, Canada
| | - Z S Bagheri
- Mechanical Engineering Department, McGill University, Montreal, Quebec H3G 1A4, Canada
| | - R B Johnston
- Mechanical Engineering Department, McGill University, Montreal, Quebec H3G 1A4, Canada
| | - L Liu
- Mechanical Engineering Department, McGill University, Montreal, Quebec H3G 1A4, Canada
| | - M Tanzer
- Division of Orthopaedics, Department of Surgery, McGill University, Montreal, Quebec H3G 1A4, Canada
| | - D Pasini
- Mechanical Engineering Department, McGill University, Montreal, Quebec H3G 1A4, Canada.
| |
Collapse
|
49
|
Lu T, Liu C, Yang B, Liu J, Zhang F, Wang D, Li H, He X. Single-Level Anterior Cervical Corpectomy and Fusion Using a New 3D-Printed Anatomy-Adaptive Titanium Mesh Cage for Treatment of Cervical Spondylotic Myelopathy and Ossification of the Posterior Longitudinal Ligament: A Retrospective Case Series Study. Med Sci Monit 2017. [PMID: 28647748 PMCID: PMC5498126 DOI: 10.12659/msm.901993] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND The aim of this study was to evaluate the clinical and radiological outcomes of the use of a new 3D-printed anatomy-adaptive titanium mesh cage (AA-TMC) for single-level anterior cervical corpectomy and fusion (ACCF) in patients with cervical spondylotic myelopathy (CSM) and ossification of the posterior longitudinal ligament (OPLL). MATERIAL AND METHODS We retrospectively reviewed the records of 15 consecutive patients who underwent ACCF surgeries with AA-TMC implantation. The Japanese Orthopedic Association (JOA) scoring system, a visual analogue scale (VAS), the mean intervertebral height (MIBH) of the surgical segments, and the surgical segmental angle (SSA) were recorded preoperatively, immediately after surgery and at the final follow-up visit. The outcomes of these parameters at different time points were compared. RESULTS Six months after ACCF surgery, solid bony fusions of the surgical level were achieved in all patients. The mean MIBH was 21.05±1.99 mm preoperatively, 27.51±1.44 mm immediately after surgery (P<0.05), and 26.85±1.25 mm at the last follow-up visit (P<0.05). At the last follow-up visit, none of the AA-TMCs exhibited severe subsidence (>3 mm). The mean SSA was 6.66±7.08° preoperatively, 14.03±2.3° immediately after surgery (P<0.05), and 15.09±2.1° at the final follow-up visit (P>0.05). The mean VAS and JOA scores were 6.6±1.26 and 10.47±2.07, respectively, preoperatively and 2.47±1.3 and 13.6±1.96 immediately after surgery, respectively (P<0.05). At the last follow-up visit, the mean VAS and JOA were further restored to 1.67±1.18 and 14.9±1.39, respectively (P<0.05). CONCLUSIONS The application of the AA-TMC in single-level ACCF significantly relieved symptoms of CSM and OPLL. The rational design of the AA-TMC restores the surgical segmental curvature, maintains the intervertebral height, and prevents postoperative subsidence-related complications.
Collapse
Affiliation(s)
- Teng Lu
- Department of Orthopaedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Chao Liu
- Department of Education, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Baohui Yang
- Department of Orthopaedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Jiantao Liu
- Department of Orthopaedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Feng Zhang
- Department of Orthopaedics, Xi'an Fourth People's Hospital, Xi'an, Shaanxi, China (mainland)
| | - Dong Wang
- Department of Orthopaedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Haopeng Li
- Department of Orthopaedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Xijing He
- Department of Orthopaedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| |
Collapse
|
50
|
Lu T, Liang H, Liu C, Guo S, Zhang T, Yang B, He X. Effects of Titanium Mesh Cage End Structures on the Compressive Load at the Endplate Interface: A Cadaveric Biomechanical Study. Med Sci Monit 2017; 23:2863-2870. [PMID: 28604653 PMCID: PMC5478219 DOI: 10.12659/msm.905466] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Background This study aimed to evaluate whether obliquely angled and ring-shaped titanium mesh cage (TMC) end structures can improve the compressive load on the endplate interface in anterior cervical corpectomy and fusion (ACCF). Material/Methods A total of 23 volunteers underwent cervical lateral x-ray. The oblique angle of the superior endplate was measured, which was used to construct the gradient of the TMC end. Forty-two fresh cadaveric vertebral bodies were harvested and randomly distributed among four TMC groups with different ends. The baseline indicators of bone mineral density and anteroposterior and transverse dimensions were recorded. The superior endplate was placed at an angle of 12° when performing uniaxial compression testing. The maximum loads of the four TMCs were assessed. Results There were no significant differences among the groups regarding the baseline indicators. The conventional TMC had the lowest maximum load (1362.3±221.78 N, p<0.05), whereas the TMC with an obliquely end ring had the highest maximum load (2095.82±285.64 N, p<0.05). The maximum loads of the TMCs with oblique footprints and flat end ring were much higher than that of the conventional TMC (p<0.05) but significantly lower than that of the TMC with the obliquely end ring (p<0.05), with average values of 1806.91±246.98 N and 1725.3±213.33 N, respectively. Conclusions Both the ring shape and oblique angle of the TMC end contributed to an increase in compressive force and are advocated for use in TMC structure optimization to decrease the incidence of TMC subsidence in ACCF.
Collapse
Affiliation(s)
- Teng Lu
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Hui Liang
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Chao Liu
- Department of Education, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Shuai Guo
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Ting Zhang
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Baohui Yang
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| | - Xijing He
- Department of Orthopaedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China (mainland)
| |
Collapse
|