1
|
Performance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia. J Clin Monit Comput 2023; 37:71-81. [PMID: 35441313 PMCID: PMC9852153 DOI: 10.1007/s10877-022-00860-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 03/30/2022] [Indexed: 01/24/2023]
Abstract
Many processed EEG monitors (pEEG) are unreliable when non-GABAergic anesthetic agents are used. The primary aim of the study was to compare the response of the Bispectral Index (BIS) during emergence from anesthesia maintained by xenon and sevoflurane. To better understand the variation in response of pEEG to these agents, we also compared several EEG derived parameters relevant to pEEG monitoring during emergence. Twenty-four participants scheduled for lithotripsy were randomized to receive xenon or sevoflurane anesthesia. Participants were monitored with the BIS and had simultaneous raw EEG collected. BIS index values were compared at three key emergence timepoints: first response, eyes open and removal of airway. Two sets of EEG derived parameters, three related to the BIS: relative beta ratio, SynchFastSlow and SynchFastSlow biocoherence, and two unrelated to the BIS: spectral edge frequency and the composite cortical state, were calculated for comparison. BIS index values were significantly lower in the xenon group than the sevoflurane group at each emergence timepoint. The relative beta ratio parameter increased significantly during emergence in the sevoflurane group but not in the xenon group. The spectral edge frequency and composite cortical state parameters increased significantly in both groups during emergence. The BIS index is lower at equivalent stages of behavioural response during emergence from xenon anesthesia when compared to sevoflurane anesthesia, most likely due to differences in how these two agents influence the relative beta ratio. The spectral edge frequency and composite cortical state might better reflect emergence from xenon anaesthesia.Clinical trial number and registry Australia New Zealand Clinical Trials Registry Number: ACTRN12618000916246.
Collapse
|
2
|
McGuigan S, Evered L, Silbert B, Scott DA, Cormack JR, Devapalasundaram A, Liley DTJ. Comparison of the Spectral Features of the Frontal Electroencephalogram in Patients Receiving Xenon and Sevoflurane General Anesthesia. Anesth Analg 2021; 133:1269-1279. [PMID: 34081045 DOI: 10.1213/ane.0000000000005608] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Depth-of-anesthesia monitoring is often utilized for patients receiving xenon anesthesia. Processed electroencephalogram (EEG) depth-of-anesthesia monitoring relies to a significant extent on frequency domain analysis of the frontal EEG, and there is evidence that the spectral features observed under anesthesia vary significantly between anesthetic agents. The spectral features of the EEG during xenon anesthesia for a surgical procedure have not previously been described. METHODS Twenty-four participants scheduled for general anesthesia for lithotripsy were randomized to receive either xenon anesthesia or sevoflurane anesthesia. Frontal EEG recordings were obtained from each participant via the Brain Anesthesia Response Monitor (BARM). Twenty-two EEG recordings were suitable for analysis: 11 in participants who received sevoflurane and 11 in participants who received xenon. Spectrograms for the duration of the anesthetic episode were produced for each participant. Group-level spectral analysis was calculated for two 30-second EEG epochs: one recorded at awake baseline and the other during maintenance anesthesia. A linear mixed-effects model was utilized to compare the changes in 5 frequency bands from baseline to maintenance between the 2 groups. RESULTS The spectrograms of sevoflurane participants illustrate an increase in frontal delta (0.5-4 Hz), theta (4-8 Hz), and alpha (8-13 Hz) band power during maintenance anesthesia. In contrast, spectrograms of the xenon participants did not illustrate an increase in alpha power. The results of the linear mixed-effects model indicate that both agents were associated with a significant increase in delta power from baseline to maintenance. There was no significant difference in the magnitude of this increase observed between the agents. In contrast, sevoflurane anesthesia was associated with significantly greater absolute power in the theta, alpha, and beta (13-30 Hz) bands when compared to xenon. In terms of relative power, xenon was associated with a significant increase in delta power compared to sevoflurane, while sevoflurane was associated with greater increases in relative theta, alpha, and beta power. CONCLUSIONS Both xenon anesthesia and sevoflurane anesthesia were associated with significant increases in delta power. Sevoflurane anesthesia was also associated with increases in theta, alpha, and beta power, while xenon anesthesia was associated with greater consolidation of power in the delta band. Xenon anesthesia and sevoflurane anesthesia are associated with distinct spectral features. These findings suggest that appropriate depth-of-anesthesia monitoring may require the development of agent-specific spectral measures of unconsciousness.
Collapse
Affiliation(s)
- Steven McGuigan
- From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia.,the Department of Medicine, Dentistry and Health Sciences, University of Melbourne, Australia
| | - Lisbeth Evered
- From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia.,the Department of Medicine, Dentistry and Health Sciences, University of Melbourne, Australia
| | - Brendan Silbert
- From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia.,the Department of Medicine, Dentistry and Health Sciences, University of Melbourne, Australia
| | - David A Scott
- From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia.,the Department of Medicine, Dentistry and Health Sciences, University of Melbourne, Australia
| | - John R Cormack
- From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia
| | - Abarna Devapalasundaram
- From the Department of Anesthesia and Acute Pain Medicine, St. Vincent's Hospital, Melbourne, Australia
| | - David T J Liley
- the Department of Medicine, Dentistry and Health Sciences, University of Melbourne, Australia
| |
Collapse
|
3
|
Devroe S, Devriese L, Debuck F, Fieuws S, Cools B, Gewillig M, Van de Velde M, Rex S. Effect of xenon and dexmedetomidine as adjuncts for general anesthesia on postoperative emergence delirium after elective cardiac catheterization in children: study protocol for a randomized, controlled, pilot trial. Trials 2020; 21:310. [PMID: 32245513 PMCID: PMC7126401 DOI: 10.1186/s13063-020-4231-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Accepted: 03/04/2020] [Indexed: 12/29/2022] Open
Abstract
Background Emergence delirium, a manifestation of acute postoperative brain dysfunction, is frequently observed after pediatric anesthesia and has been associated with the use of sevoflurane. Both xenon and dexmedetomidine possess numerous desirable properties for the anesthesia of children with congenital heart disease, including hemodynamic stability, lack of neurotoxicity, and a reduced incidence of emergence delirium. Combining both drugs has never been studied as a balanced-anesthesia technique. This combination allows the provision of anesthesia without administering anesthetic drugs against which the Food and Drug Administration (FDA) issued a warning for the use in young children. Methods/Design In this phase-II, mono-center, prospective, single-blinded, randomized, controlled pilot trial, we will include a total of 80 children aged 0–3 years suffering from congenital heart disease and undergoing general anesthesia for elective diagnostic and/or interventional cardiac catheterization. Patients are randomized into two study groups, receiving either a combination of xenon and dexmedetomidine or mono-anesthesia with sevoflurane for the maintenance of anesthesia. The purpose of this study is to estimate the effect size for xenon-dexmedetomidine versus sevoflurane anesthesia with respect to the incidence of emergence delirium in children. We will also describe group differences for a variety of secondary outcome parameters including peri-interventional hemodynamics, emergence characteristics, incidence of postoperative vomiting, and the feasibility of a combined xenon-dexmedetomidine anesthesia in children. Discussion Sevoflurane is the most frequently used anesthetic in young children, but has been indicated as an independent risk factor in the development of emergence delirium. Xenon and dexmedetomidine have both been associated with a reduction in the incidence of emergence delirium. Combining xenon and dexmedetomidine has never been described as a balanced-anesthesia technique in children. Our pilot study will therefore deliver important data required for future prospective clinical trials. Trial registration EudraCT, 2018–002258-56. Registered on 20 August 2018. https://www.clinicaltrialsregister.eu.
Collapse
Affiliation(s)
- Sarah Devroe
- Department of Anesthesiology, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium. .,Department of Pediatric and Congenital Cardiology, University Hospitals Leuven, Leuven, Belgium.
| | - Lisa Devriese
- Department of Anesthesiology, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Frederik Debuck
- Department of Anesthesiology, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Steffen Fieuws
- I-Biostat, KU Leuven - University of Leuven, Leuven, Belgium
| | - Bjorn Cools
- Department of Pediatric and Congenital Cardiology, University Hospitals Leuven, Leuven, Belgium.,Department of Cardiovascular Sciences, Katholieke Universiteit (KU) Leuven, Leuven, Belgium
| | - Marc Gewillig
- Department of Pediatric and Congenital Cardiology, University Hospitals Leuven, Leuven, Belgium.,Department of Cardiovascular Sciences, Katholieke Universiteit (KU) Leuven, Leuven, Belgium
| | - Marc Van de Velde
- Department of Anesthesiology, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium.,Department of Cardiovascular Sciences, Katholieke Universiteit (KU) Leuven, Leuven, Belgium
| | - Steffen Rex
- Department of Anesthesiology, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium.,Department of Cardiovascular Sciences, Katholieke Universiteit (KU) Leuven, Leuven, Belgium
| |
Collapse
|
4
|
Xia Y, Fang H, Xu J, Jia C, Tao G, Yu B. Clinical efficacy of xenon versus propofol: A systematic review and meta-analysis. Medicine (Baltimore) 2018; 97:e10758. [PMID: 29768360 PMCID: PMC5976329 DOI: 10.1097/md.0000000000010758] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Accepted: 04/25/2018] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Interest in the anesthetic use of xenon, a noble gas, has waxed and waned for decades, and the clinical effects of xenon are still debated. We performed a meta-analysis to compare the clinical efficacy of xenon with that of propofol. METHODS Electronic searches were performed through December 2017 using various databases, including PubMed, Embase, and the Cochrane Library. We identified thirteen trials that included a total of 817 patients. RESULTS Patients treated with xenon had a lower bispectral index (BIS) (weighted mean difference (WMD): -6.26, 95% confidence interval (CI): -11.33 to -1.18, P = .02), a higher mean arterial blood pressure (MAP) (WMD: 7.00, 95% CI: 2.32-11.68, P = .003) and a lower heart rate (HR) (WMD: -9.45, 95% CI: -12.28 to -6.63, P < 0.00001) than propofol-treated patients. However, there were no significant differences between the 2 treatment groups in the effects of nondepolarizing muscular relaxants, the duration spent in the postanesthesia care unit (PACU) (WMD: -0.94, 95% CI: -8.79-6.91, P = .81), or the incidence of perioperative complications [assessed using the outcomes of postoperative nausea and vomiting (PONV) (relative risk (RR): 2.01, 95% CI: 0.79-5.11, P = .14), hypotension (RR: 0.62, 95% CI: 0.27 to 1.40, P = .25), hypertension (RR: 1.27, 95% CI: 0.73-2.21, P = .39) and bradycardia (RR: 1.00, 95% CI: 0.36-2.74, P = 1.00)]. CONCLUSION In this meta-analysis of randomized controlled trials, we found that xenon treatment resulted in a higher MAP, a lower HR, and a smaller BIS index than treatment with propofol.
Collapse
Affiliation(s)
- Yimeng Xia
- Department of Anaesthesiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine
| | - Hongwei Fang
- Department of Anaesthesiology and Intensive Care Unit, Dongfang Hospital, Tongji University School of Medicine, Shanghai
| | - Jindong Xu
- Department of Anaesthesiology, Guangdong Cardiovascular Institute & Guangdong General
| | - Chenfei Jia
- Department of Anaesthesiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine
| | - Guorong Tao
- Department of Anaesthesiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine
| | - Buwei Yu
- Department of Anaesthesiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine
| |
Collapse
|
5
|
Al tmimi L, Devroe S, Dewinter G, Van de Velde M, Poortmans G, Meyns B, Meuris B, Coburn M, Rex S. Xenon as an Adjuvant to Propofol Anesthesia in Patients Undergoing Off-Pump Coronary Artery Bypass Graft Surgery. Anesth Analg 2017; 125:1118-1128. [DOI: 10.1213/ane.0000000000002179] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
6
|
Yang N, Yue Y, Pan JZ, Zuo MZ, Shi Y, Zhou SZ, Peng WP, Gao JD. Changes in the Bispectral Index in Response to Loss of Consciousness and No Somatic Movement to Nociceptive Stimuli in Elderly Patients. Chin Med J (Engl) 2017; 129:410-6. [PMID: 26879014 PMCID: PMC4800841 DOI: 10.4103/0366-6999.176083] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Background: Bispectral index (BIS) is considered very useful to guide anesthesia care in elderly patients, but its use is controversial for the evaluation of the adequacy of analgesia. This study compared the BIS changes in response to loss of consciousness (LOC) and loss of somatic response (LOS) to nociceptive stimuli between elderly and young patients receiving intravenous target-controlled infusion (TCI) of propofol and remifentanil. Methods: This study was performed on 52 elderly patients (aged 65–78 years) and 52 young patients (aged 25–58 years), American Society of Anesthesiologists physical status I or II. Anesthesia was induced with propofol administered by TCI. A standardized noxious electrical stimulus (transcutaneous electrical nerve stimulation, [TENS]) was applied (50 Hz, 80 mA, 0.25 ms pulses for 4 s) to the ulnar nerve at increasing remifentanil predicted effective-site concentration (Ce) until patients lost somatic response to TENS. Changes in awake, prestimulus, poststimulus BIS, heart rate, mean arterial pressure, pulse oxygen saturation, predicted plasma concentration, Ce of propofol, and remifentanil at both LOC and LOS clinical points were investigated. Results: BISLOC in elderly group was higher than that in young patient group (65.4 ± 9.7 vs. 57.6 ± 12.3) (t = 21.58, P < 0.0001) after TCI propofol, and the propofol Ce at LOC was 1.6 ± 0.3 μg/ml in elderly patients, which was significantly lower than that in young patients (2.3 ± 0.5 μg/ml) (t = 7.474, P < 0.0001). As nociceptive stimulation induced BIS to increase, the mean of BIS maximum values after TENS was significantly higher than that before TENS in both age groups (t = 8.902 and t = 8.019, P < 0.0001). With increasing Ce of remifentanil until patients lost somatic response to TENS, BISLOS was the same as the BISLOC in elderly patients (65.6 ± 10.7 vs. 65.4 ± 9.7), and there were no marked differences between elderly and young patient groups in BISawake, BISLOS, and Ce of remifentanil required for LOS. Conclusion: In elderly patients, BIS can be used as an indicator for hypnotic-analgesic balance and be helpful to guide the optimal administration of propofol and remifentanil individually. Trial Registration: CTRI Reg. No: ChiCTR-OOC-14005629; http://www.chictr.org.cn/showproj.aspx?proj=9875.
Collapse
Affiliation(s)
| | - Yun Yue
- Department of Anesthesiology, Beijing Chao-Yang Hospital, Capital Medical University, Beijing 100020, China
| | | | | | | | | | | | | |
Collapse
|
7
|
Hajat Z, Ahmad N, Andrzejowski J. The role and limitations of EEG-based depth of anaesthesia monitoring in theatres and intensive care. Anaesthesia 2017; 72 Suppl 1:38-47. [DOI: 10.1111/anae.13739] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/29/2016] [Indexed: 12/14/2022]
Affiliation(s)
- Z. Hajat
- Sheffield Teaching Hospitals NHS Trust; Sheffield UK
| | - N. Ahmad
- Sheffield Teaching Hospitals NHS Trust; Sheffield UK
| | | |
Collapse
|
8
|
Messina AG, Wang M, Ward MJ, Wilker CC, Smith BB, Vezina DP, Pace NL. Anaesthetic interventions for prevention of awareness during surgery. Cochrane Database Syst Rev 2016; 10:CD007272. [PMID: 27755648 PMCID: PMC6461159 DOI: 10.1002/14651858.cd007272.pub2] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
BACKGROUND General anaesthesia is usually associated with unconsciousness. 'Awareness' is when patients have postoperative recall of events or experiences during surgery. 'Wakefulness' is when patients become conscious during surgery, but have no postoperative recollection of the period of consciousness. OBJECTIVES To evaluate the efficacy of two types of anaesthetic interventions in reducing clinically significant awareness:- anaesthetic drug regimens; and- intraoperative anaesthetic depth monitors. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL, ISSUE 4 2016); PubMed from 1950 to April 2016; MEDLINE from 1950 to April 2016; and Embase from 1980 to April 2016. We contacted experts to identify additional studies. We performed a handsearch of the citations in the review. We did not search trial registries. SELECTION CRITERIA We included randomized controlled trials (RCTs) of either anaesthetic regimens or anaesthetic depth monitors. We excluded volunteer studies, studies of patients prior to skin incision, intensive care unit studies, and studies that only randomized different word presentations for memory tests (not anaesthetic interventions).Anaesthetic drug regimens included studies of induction or maintenance, or both. Anaesthetic depth monitors included the Bispectral Index monitor, M-Entropy, Narcotrend monitor, cerebral function monitor, cerebral state monitor, patient state index, and lower oesophageal contractility monitor. The use of anaesthetic depth monitors allows the titration of anaesthetic drugs to maintain unconsciousness. DATA COLLECTION AND ANALYSIS At least two authors independently scanned abstracts, extracted data from the studies, and evaluated studies for risk of bias. We made attempts to contact all authors for additional clarification. We performed meta-analysis statistics in packages of the R language. MAIN RESULTS We included 160 studies with 54,109 enrolled participants; 53,713 participants started the studies and 50,034 completed the studies or data analysis (or both). We could not use 115 RCTs in meta-analytic comparisons because they had zero awareness events. We did not merge 27 of the remaining 45 studies because they had excessive clinical and methodological heterogeneity. We pooled the remaining 18 eligible RCTs in meta-analysis. There are 10 studies awaiting classification which we will process when we update the review.The meta-analyses included 18 trials with 36,034 participants. In the analysis of anaesthetic depth monitoring (either Bispectral Index or M-entropy) versus standard clinical and electronic monitoring, there were nine trials with 34,744 participants. The overall event rate was 0.5%. The effect favoured neither anaesthetic depth monitoring nor standard clinical and electronic monitoring, with little precision in the odds ratio (OR) estimate (OR 0.98, 95% confidence interval (CI) 0.59 to 1.62).In a five-study subset of Bispectral Index monitoring versus standard clinical and electronic monitoring, with 34,181 participants, 503 participants gave awareness reports to a blinded, expert panel who adjudicated or judged the outcome for each patient after reviewing the questionnaires: no awareness, possible awareness, or definite awareness. Experts judged 351 patient awareness reports to have no awareness, 87 to have possible awareness, and 65 to have definite awareness. The effect size favoured neither Bispectral Index monitoring nor standard clinical and electronic monitoring, with little precision in the OR estimate for the combination of definite and possible awareness (OR 0.96, 95% CI 0.35 to 2.65). The effect size favoured Bispectral Index monitoring for definite awareness, but with little precision in the OR estimate (OR 0.60, 95% CI 0.13 to 2.75).We performed three smaller meta-analyses of anaesthetic drugs. There were nine studies with 1290 participants. Wakefulness was reduced by ketamine and etomidate compared to thiopental. Wakefulness was more frequent than awareness. Benzodiazepines reduces awareness compared to thiopental, ketamine, and placebo., Also, higher doses of inhaled anaesthetics versus lower doses reduced the risk of awareness.We graded the quality of the evidence as low or very low in the 'Summary of findings' tables for the five comparisons.Most of the secondary outcomes in this review were not reported in the included RCTs. AUTHORS' CONCLUSIONS Anaesthetic depth monitors may have similar effects to standard clinical and electrical monitoring on the risk of awareness during surgery. In older studies comparing anaesthetics in a smaller portion of the patient sample, wakefulness occurred more frequently than awareness. Use of etomidate and ketamine lowered the risk of wakefulness compared to thiopental. Benzodiazepines compared to thiopental and ketamine, or higher doses of inhaled anaesthetics versus lower doses, reduced the risk of awareness.
Collapse
Affiliation(s)
- Anthony G Messina
- School of Management, University of Texas at DallasThe Alliance for Medical Management EducationBox 2331920 N. Coit RoadRichardsonTXUSA75080
| | - Michael Wang
- University of LeicesterClinical Psychology UnitLancaster RoadLeicesterUKLE1 7HA
| | - Marshall J Ward
- Dartmouth‐Hitchcock Medical Center1 Medical Center DrLebanonNHUSA03766
| | - Chase C Wilker
- ARUP LaboratoriesClinical Toxicology IIISalt Lake CityUTUSA
| | - Brett B Smith
- University of UtahUniversity of Utah School of MedicineSalt Lake CityUTUSA84112
| | - Daniel P Vezina
- University of UtahDepartment of Anesthesiology, Department of Internal Medicine, Division of CardiologySalt Lake CityUTUSA
- Veteran's AdministrationEchocardiography LaboratorySalt Lake CityUTUSA
| | - Nathan Leon Pace
- University of UtahDepartment of Anesthesiology3C444 SOM30 North 1900 EastSalt Lake CityUTUSA84132‐2304
| | | |
Collapse
|
9
|
|
10
|
Sabir H, Wood T, Gill H, Liu X, Dingley J, Thoresen M. Xenon depresses aEEG background voltage activity whilst maintaining cardiovascular stability in sedated healthy newborn pigs. J Neurol Sci 2016; 363:140-4. [PMID: 27000239 DOI: 10.1016/j.jns.2016.02.051] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2015] [Revised: 01/25/2016] [Accepted: 02/19/2016] [Indexed: 10/22/2022]
Abstract
BACKGROUND Changes in electroencephalography (EEG) voltage range are used to monitor the depth of anaesthesia, as well as predict outcome after hypoxia-ischaemia in neonates. Xenon is being investigated as a potential neuroprotectant after hypoxic-ischaemic brain injury, but the effect of Xenon on EEG parameters in children or neonates is not known. This study aimed to examine the effect of 50% inhaled Xenon on background amplitude-integrated EEG (aEEG) activity in sedated healthy newborn pigs. METHODS Five healthy newborn pigs, receiving intravenous fentanyl sedation, were ventilated for 24 h with 50%Xenon, 30%O2 and 20%N2 at normothermia. The upper and lower voltage-range of the aEEG was continuously monitored together with cardiovascular parameters throughout a 1 h baseline period with fentanyl sedation only, followed by 24 h of Xenon administration. RESULTS The median (IQR) upper and lower aEEG voltage during 1 h baseline was 48.0 μV (46.0-50.0) and 25.0 μV (23.0-26.0), respectively. The median (IQR) aEEG upper and lower voltage ranges were significantly depressed to 21.5 μV (20.0-26.5) and 12.0 μV (12.0-16.5) from 10 min after the onset of 50% Xenon administration (p=0.002). After the initial Xenon induced depression in background aEEG voltage, no further aEEG changes were seen over the following 24h of ventilation with 50% xenon under fentanyl sedation. Mean arterial blood pressure and heart rate remained stable. CONCLUSION Mean arterial blood pressure and heart rate were not significantly influenced by 24h Xenon ventilation. 50% Xenon rapidly depresses background aEEG voltage to a steady ~50% lower level in sedated healthy newborn pigs. Therefore, care must be taken when interpreting the background voltage in neonates also receiving Xenon.
Collapse
Affiliation(s)
- Hemmen Sabir
- School of Clinical Sciences, University of Bristol, St Michael's Hospital, Bristol, United Kingdom; Departments of General Pediatrics, Neonatology and Pediatric Cardiology, University Children's Hospital, Düsseldorf, Heinrich-Heine University Düsseldorf, Germany
| | - Thomas Wood
- Department of Physiology, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
| | - Hannah Gill
- School of Clinical Sciences, University of Bristol, St Michael's Hospital, Bristol, United Kingdom
| | - Xun Liu
- School of Clinical Sciences, University of Bristol, St Michael's Hospital, Bristol, United Kingdom
| | - John Dingley
- College of Medicine, Swansea University, United Kingdom
| | - Marianne Thoresen
- School of Clinical Sciences, University of Bristol, St Michael's Hospital, Bristol, United Kingdom; Department of Physiology, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway.
| |
Collapse
|
11
|
Comparison of recovery parameters for xenon versus other inhalation anesthetics: systematic review and meta-analysis. J Clin Anesth 2016; 29:65-74. [PMID: 26897451 DOI: 10.1016/j.jclinane.2015.10.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2014] [Accepted: 10/29/2015] [Indexed: 11/22/2022]
Abstract
STUDY OBJECTIVE To summarize and evaluate the available data describing the recovery parameters of xenon anesthesia. DESIGN Systematic review and meta-analysis. SETTING Anesthesia for elective surgeries. PATIENTS Systematic review of randomized controlled trials (RCTs) from databases including Medline (1964-2013), the Cochrane Central Register of Controlled Trials (CENTRAL, 1990-2012), and Google Scholar (1966-2013). INTERVENTIONS Inhalation of xenon or other anesthetics was administered in elective surgery. MEASUREMENTS Recovery parameters (time to recovery, alertness/sedation scale scores at "eye opening," bispectral index at "reaction on demand," time to extubation, and time to orientation). MAIN RESULTS Eleven RCTs (N = 661 patients) met the inclusion criteria. Recovery from xenon anesthesia was significantly faster in terms of the time to eye opening (mean difference [MD], -4.18 minutes; 95% confidence interval [CI], -5.03 to -3.32 minutes; P < .00001), the time to reaction on demand (MD, -5.35 minutes; 95% CI, -6.59 to -4.11 minutes; P < .00001), the time to extubation (MD, -4.49 minutes; 95% CI, -5.40 to -3.58 minutes; P < .00001), and the time to orientation (MD, -4.99 minutes; 95% CI, -6.45 to -3.52 minutes; P < .00001). CONCLUSIONS This meta-analysis confirmed that recovery from xenon anesthesia is faster than other inhalation anesthesia.
Collapse
|
12
|
Current World Literature. Curr Opin Anaesthesiol 2012; 25:111-20. [DOI: 10.1097/aco.0b013e32834fd93c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
13
|
Stoppe C, Peters D, Fahlenkamp AV, Cremer J, Rex S, Schälte G, Rossaint R, Coburn M. aepEX monitor for the measurement of hypnotic depth in patients undergoing balanced xenon anaesthesia. Br J Anaesth 2011; 108:80-8. [PMID: 22139005 DOI: 10.1093/bja/aer393] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Previously, we showed a significant difference in the measurements of hypnotic depth by the bispectral index (BIS) and auditory-evoked potentials (AEPs) using the A-line autoregressive index during xenon anaesthesia. In the present study, we evaluate the alternative AEP-based auditory-evoked potential index (aepEX) for the measurement of hypnotic depth in patients undergoing general anaesthesia with xenon. METHODS Forty-two patients undergoing elective abdominal surgery were enrolled in this controlled, double-blinded, randomized, clinical study. Patients were randomized to receive either xenon (n=21) or sevoflurane anaesthesia (n=21). During anaesthesia, BIS values were recorded simultaneously with the aepEX monitoring. The anaesthetist performing the anaesthesia was blinded to the hypnotic depth monitors. After surgery, the incidence of recalls and awareness was evaluated. RESULTS Patients' characteristics such as gender, age, and weight did not differ between the groups. The aepEX and BIS values behaved similarly during anaesthesia. The comparison of aepEX values during xenon and sevoflurane anaesthesia revealed significantly lower aepEX values in the xenon group after 25 min [xenon: 32.9 (4.8) vs sevoflurane: 39.3 (9.0); P=0.008] and after 35 min [xenon: 31.4 (6.6) vs sevoflurane: 37.0 (6.8); P=0.012]. During anaesthesia, aepEX values correlated with the clinical evaluation of depth of anaesthesia (e.g. >20% changes of the baseline arterial pressure or heart rate, spontaneous breathing and/or intolerance of mechanical ventilation, coughing, abdominal pressing, sweating, eye tearing). CONCLUSIONS We found the aepEX monitor to provide index in the range of adequate depth of xenon anaesthesia, when combined with remifentanil infusion in intubated patients undergoing elective abdominal surgery.
Collapse
Affiliation(s)
- C Stoppe
- Department of Anaesthesiology, RWTH University Hospital, Pauwelsstr. 30, D-52074 Aachen, Germany
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Current World Literature. Curr Opin Anaesthesiol 2011; 24:705-12. [DOI: 10.1097/aco.0b013e32834e25f9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
15
|
Bibliography. Obstetric and gynaecological anesthesia. Current world literature. Curr Opin Anaesthesiol 2011; 24:354-6. [PMID: 21637164 DOI: 10.1097/aco.0b013e328347b491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
16
|
Cremer J, Stoppe C, Fahlenkamp AV, Schälte G, Rex S, Rossaint R, Coburn M. Early cognitive function, recovery and well-being after sevoflurane and xenon anaesthesia in the elderly: a double-blinded randomized controlled trial. Med Gas Res 2011; 1:9. [PMID: 22146537 PMCID: PMC3231879 DOI: 10.1186/2045-9912-1-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2011] [Accepted: 05/18/2011] [Indexed: 11/10/2022] Open
Abstract
Background The postoperative cognitive function is impaired in elderly patients after general anaesthesia. The fast recovery after xenon anaesthesia was hypothesized to be advantageous in this scenario. We compared early postoperative cognitive function after xenon and sevoflurane anaesthesia in this study. Methods The study was approved by the local ethics committee and written informed consent was obtained from each patient. Patients aged 65-75 years (ASA I-III) scheduled for elective surgery (duration 60-180 min) were enrolled. Investigators performing cognitive testing and patients were blinded towards allocation to either xenon or sevoflurane anaesthesia. Baseline assessment of cognitive function was carried out 12-24 h before the operation. The results were compared to follow-up tests 6-12 and 66-72 h after surgery. Primary outcome parameter was the subtest "Alertness" of the computerized Test of Attentional Performance (TAP). Secondary outcome parameters included further subtests of the TAP, several Paper-Pencil-Tests, emergence times from anaesthesia, modified Aldrete scores and patients' well-being. Results 40 patients were randomized and equally allocated to both groups. No significant differences were found in the TAP or the Paper-Pencil-Tests at 6-12 and 66-72 h after the operation. All emergence times were faster after xenon anaesthesia. The modified Aldrete scores were significantly higher during the first hour in the xenon group. No difference in well-being could be detected between both groups. Conclusions The results show no difference in the incidence of postoperative cognitive dysfunction (POCD) after xenon or sevoflurane anaesthesia. Emergence from general anaesthesia was faster in the xenon group.
Collapse
Affiliation(s)
- Jan Cremer
- Department of Anaesthesiology, University Hospital Aachen of the RWTH Aachen, Pauwelsstraße 30, D-52074 Aachen, Germany.
| | | | | | | | | | | | | |
Collapse
|