Liu Q, Zhao S, Zhang Y, Fang Q, Liu W, Wu R, Wei G, Wei H, Du Y. Nanozyme-Cosmetic Contact Lenses for Ocular Surface Disease Prevention. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2305555. [PMID: 37584617 DOI: 10.1002/adma.202305555] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Revised: 07/25/2023] [Indexed: 08/17/2023]
Abstract
Efficiently balancing excess reactive oxygen species (ROS) caused by various factors on the ocular surface is a promising strategy for preventing the development of ocular surface diseases (OSDs). Nevertheless, the conventional topical administration of antioxidants is limited in efficacy due to poor absorption, rapid metabolism, and irreversible depletion, which impede their performance. To address this issue, contact lenses embedded with antioxidant nanozymes that can continuously scavenge ROS, thereby providing an excellent preventive effect against OSDs are developed. Specifically, Prussian blue family nanozymes are chosen based on their multiple antioxidant enzyme-like activities and excellent biocompatibility. The diverse range of colors made them promising candidates for the development of cosmetic contact lenses (CCLs) as a substitute for conventional pigments. The efficacy of nanozyme-CCLs is demonstrated in rabbits and rats exposed to a high risk of developing OSDs. These OSDs' prevention nanozyme-CCLs can pave the way for CCLs toward powerful wearable biomedical devices and provide novel strategies for the rational utilization of nanomaterials in clinical practice.
Collapse
Affiliation(s)
- Quanyi Liu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin, 130022, China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, Anhui, 230026, China
| | - Sheng Zhao
- College of Engineering and Applied Sciences, Nanjing National Laboratory of Microstructures, Jiangsu Key Laboratory of Artificial Functional Materials, Nanjing University, Nanjing, Jiangsu, 210023, China
| | - Yihong Zhang
- College of Engineering and Applied Sciences, Nanjing National Laboratory of Microstructures, Jiangsu Key Laboratory of Artificial Functional Materials, Nanjing University, Nanjing, Jiangsu, 210023, China
| | - Qi Fang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin, 130022, China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, Anhui, 230026, China
| | - Wanling Liu
- College of Engineering and Applied Sciences, Nanjing National Laboratory of Microstructures, Jiangsu Key Laboratory of Artificial Functional Materials, Nanjing University, Nanjing, Jiangsu, 210023, China
| | - Rong Wu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin, 130022, China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, Anhui, 230026, China
| | - Gen Wei
- College of Engineering and Applied Sciences, Nanjing National Laboratory of Microstructures, Jiangsu Key Laboratory of Artificial Functional Materials, Nanjing University, Nanjing, Jiangsu, 210023, China
| | - Hui Wei
- College of Engineering and Applied Sciences, Nanjing National Laboratory of Microstructures, Jiangsu Key Laboratory of Artificial Functional Materials, Nanjing University, Nanjing, Jiangsu, 210023, China
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Chemistry and Biomedicine Innovation Center (ChemBIC), Nanjing University, Nanjing, Jiangsu, 210023, China
| | - Yan Du
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin, 130022, China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, Anhui, 230026, China
| |
Collapse
|
2
|
Shen E, Yang J, Tsuei KSC. The role of Type III secretion system in the pathogenesis of Pseudomonas aeruginosa microbial keratitis. Tzu Chi Med J 2022; 34:8-14. [PMID: 35233350 PMCID: PMC8830546 DOI: 10.4103/tcmj.tcmj_47_21] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 03/11/2021] [Accepted: 03/17/2021] [Indexed: 11/22/2022] Open
Abstract
Pseudomonas aeruginosa is the most commonly isolated Gram-negative pathogen causing sight-threatening microbial keratitis (MK). Contact lens wear is the most significant risk factor associated with pseudomonal MK. Understanding the pathogenesis of MK due to P. aeruginosa and its interactions with contact lenses is crucial in preventing these often rapidly progressive and highly antibiotic-resistant infections. Bacterial virulence factor Type III secretion system (T3SS) has significant interplays between contact lens material, antibiotic sensitivity, disinfectant selectivity, and bacterial cell invasion. Depending on the T3SS exotoxins produced, P. aeruginosa strains are divided into cytotoxic or invasive strains. Cytotoxic strains are relatively resistant to commercial disinfectants, while invasive strains are more antibiotic resistant. Therefore, contact lens wearers are more predisposed to cytotoxic P. aeruginosa infections, and patients with trauma or previous surgery are more prone to infection by invasive strains. Previous studies with mutant P. aeruginosa strains unable to produce T3SS exotoxins were more susceptible to disinfectants and less able to adhere to soft contact lenses, indicating an essential role of T3SS in bacterial virulence. Invasion of P. aeruginosa intracellularly was found to be associated with control of scaffold protein IQ-domain GTPase-activating protein 1 (IQGAP1) and human corneal epithelial cell tight junctions. Knockdown of IQGAP1 strengthened tight junctions that prevented intracellular survival of invasive P. aeruginosa strains and enhanced corneal epithelial cell survival. These novel findings of the vital role of T3SS in the pathogenesis of pseudomonal MKs will provide new guidelines in both prevention and treatment of this common eye-blinding infection.
Collapse
|
3
|
Choi SW, Cha BG, Kim J. Therapeutic Contact Lens for Scavenging Excessive Reactive Oxygen Species on the Ocular Surface. ACS NANO 2020; 14:2483-2496. [PMID: 31935066 DOI: 10.1021/acsnano.9b10145] [Citation(s) in RCA: 51] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Excessive reactive oxygen species (ROS) play a significant role in the pathogenesis of many eye diseases. Controlling oxidative stress by reducing the amount of ROS is a potential therapeutic strategy for the prevention and treatment of eye diseases, particularly ocular surface diseases. Ceria nanoparticles (CeNPs) have been investigated owing to their efficient ROS-scavenging properties. To overcome the disadvantages of eyedrop administration due to rapid elimination on the surface of the eye and to retain the intrinsic properties of contact lenses, we developed an ROS-scavenging water-soluble CeNP-embedded contact lens (CeNP-CL) for the prevention of ocular surface diseases. The intrinsic ROS-scavenging property of the CeNPs, which mimicked the activities of superoxide dismutase and catalase, was incorporated into polyhydroxyethyl methacrylate-based contact lenses. The CeNP-CL exhibited high transparency and physical properties comparable to those of a commercial contact lens, along with excellent extracellular ROS-scavenging properties. The viabilities of human conjunctival epithelial cells and human meibomian gland epithelial cells were significantly enhanced in the presence of CeNP-CLs, even in media with high H2O2 contents (100 and 500 μM). Additionally, the wearing of CeNP-CLs on the eyes had a protective effect in a mouse model when 3% H2O2 eyedrops were administered. These results indicate the salvaging effect of the CeNP-CL in a high-ROS environment on the ocular surface, which may be helpful for the treatment of ocular surface diseases.
Collapse
Affiliation(s)
- Seung Woo Choi
- Department of Health Sciences and Technology, Samsung Advanced Institute for Health Sciences & Technology (SAIHST) , Sungkyunkwan University (SKKU) , Suwon 16419 , Republic of Korea
| | - Bong Geun Cha
- School of Chemical Engineering , Sungkyunkwan University (SKKU) , Suwon 16419 , Republic of Korea
| | - Jaeyun Kim
- Department of Health Sciences and Technology, Samsung Advanced Institute for Health Sciences & Technology (SAIHST) , Sungkyunkwan University (SKKU) , Suwon 16419 , Republic of Korea
- School of Chemical Engineering , Sungkyunkwan University (SKKU) , Suwon 16419 , Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS) , Sungkyunkwan University (SKKU) , Suwon 16419 , Republic of Korea
- Institute of Quantum Biophysics (IQB) , Sungkyunkwan University (SKKU) , Suwon 16419 , Republic of Korea
| |
Collapse
|
4
|
Kim SH, Lee J, Jang YJ, Lee KB, Lee Y. ToF-SIMS and AFM Characterization of Brown Cosmetic Contact Lenses: From Structural Analysis to the Identification of Pigments. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2020; 2020:6134627. [PMID: 32399310 PMCID: PMC7204263 DOI: 10.1155/2020/6134627] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 12/24/2019] [Indexed: 06/11/2023]
Abstract
Over the years, soft contact lenses for vision correction and cosmetic and therapeutic purposes have been greatly improved. For cosmetic contact lenses, the pigments need to be nontoxic, and the position of the pigment layer is particularly important because of the risks posed by pigment elution and the roughness of the lens surface. In this paper, we characterized the properties of brown cosmetic contact lenses made by three different manufacturers using surface analytical techniques. The surface topographies of the noncolored and colored parts were obtained by atomic force microscopy (AFM), and the position and composition of the pigment layer were determined by analyzing the cross section of the contact lenses using scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDX). The influence of pigment location on surface roughness was also examined. In addition, to find the method of the evaluation for the risk of surface elution of the pigments in the colored parts, the mass spectra and ion images of the surfaces were obtained by time-of-flight secondary ion mass spectrometry (ToF-SIMS) with a new sample preparation. From the ToF-SIMS spectra, we observed specific fragment ions of the poly(hydroxyethyl methacrylate) (PHEMA) polymer and found differences in the composition of the pigment layer depending on the manufacturers. The cross-sectioned image and 3D chemical characterizations of metallic and specific ions in the brown cosmetic contact lenses clearly indicated the spatial distribution and location of the pigment layer that can be used for the evaluation of pigment elution.
Collapse
Affiliation(s)
- Seon Hee Kim
- Advanced Analysis Center, Korea Institute of Science & Technology, Seoul 02792, Republic of Korea
| | - Jihye Lee
- Advanced Analysis Center, Korea Institute of Science & Technology, Seoul 02792, Republic of Korea
| | - Yun Jung Jang
- Advanced Analysis Center, Korea Institute of Science & Technology, Seoul 02792, Republic of Korea
- Department of Materials Science and Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Kang-Bong Lee
- National Agenda Research Division, Korea Institute of Science & Technology, Seoul 02792, Republic of Korea
| | - Yeonhee Lee
- Advanced Analysis Center, Korea Institute of Science & Technology, Seoul 02792, Republic of Korea
| |
Collapse
|
5
|
Abstract
OBJECTIVES Cosmetic contact lenses are increasingly popular because of their eye enhancing cosmetic benefits. The pigment particles used in these lenses can impact lens surface characteristics. This article examines the surface characteristics and the differences between the clear and the pigmented regions among five limbal ring design lenses. METHODS Scanning electron microscopy was used to determine the location and depth of the pigment particles from the lens surface. The coefficient of friction (CoF) was determined with a Basalt-MUST microtribometer at clear and pigmented regions on either the front or the back surface. Atomic force microscopy was used to determine the surface roughness of each lens in root-mean-square (RMS) units at clear and pigmented regions. A linear mixed model for repeated measures was used for the analysis of the CoF and RMS roughness to compare all lenses. RESULTS Four lens types had pigments exposed on the surface and one lens type had pigment fully enclosed. The CoF difference between clear and pigmented regions were similar and not statistically significant (P=0.0124) for the lens type with pigments enclosed, whereas the CoF difference for the other four lens types showed statistically significant difference (P<0.0001). CONCLUSIONS Of the lenses tested here, cosmetic contact lenses with pigments enclosed in the lens matrix provided a more consistent surface between clear and pigmented regions compared with lenses that had exposed pigments.
Collapse
|
6
|
Choi SW, Kim J. Therapeutic Contact Lenses with Polymeric Vehicles for Ocular Drug Delivery: A Review. MATERIALS (BASEL, SWITZERLAND) 2018; 11:E1125. [PMID: 29966397 PMCID: PMC6073408 DOI: 10.3390/ma11071125] [Citation(s) in RCA: 56] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 06/28/2018] [Accepted: 06/29/2018] [Indexed: 12/22/2022]
Abstract
The eye has many barriers with specific anatomies that make it difficult to deliver drugs to targeted ocular tissues, and topical administration using eye drops or ointments usually needs multiple instillations to maintain the drugs’ therapeutic concentration because of their low bioavailability. A drug-eluting contact lens is one of the more promising platforms for controllable ocular drug delivery, and, among various manufacturing methods for drug-eluting contact lenses, incorporation of novel polymeric vehicles with versatile features makes it possible to deliver the drugs in a sustained and extended manner. Using the diverse physicochemical properties of polymers for nanoparticles or implants that are selected according to the characteristics of drugs, enhancement of encapsulation efficiency and prolonged drug release are possible. Even though therapeutic contact lenses with polymeric vehicles allow us to achieve sustained ocular drug delivery, drug leaching during storage and distribution and the possibility of problems related to surface roughness due to the incorporated vehicles still need to be discussed before application in a real clinic. This review highlights the overall trends in methodology to develop therapeutic contact lenses with polymeric vehicles and discusses the limitations including comparison to cosmetically tinted soft contact lenses.
Collapse
Affiliation(s)
- Seung Woo Choi
- Department of Health Sciences and Technology, Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Sungkyunkwan University (SKKU), Suwon 16419, Korea.
| | - Jaeyun Kim
- Department of Health Sciences and Technology, Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Sungkyunkwan University (SKKU), Suwon 16419, Korea.
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea.
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University (SKKU), Suwon 16419, Korea.
| |
Collapse
|