1
|
Calderón-García AÁ, López-de la Rosa A, Valencia-Nieto L, García-Vázquez C, Arroyo-Del-Arroyo C, López-Miguel A, Blanco-Vázquez M, Novo-Diez A, Fernández I, Enríquez de Salamanca A, González-García MJ. Tear Cytokines as Predictive Biomarkers of Success in Contact Lens Discomfort Management. Ocul Immunol Inflamm 2024:1-9. [PMID: 38889385 DOI: 10.1080/09273948.2024.2361114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Accepted: 05/23/2024] [Indexed: 06/20/2024]
Abstract
PURPOSE To analyze changes in tear levels of inflammatory mediators in symptomatic contact lens (CL) wearers after refitting with daily disposable CLs and to identify potential biomarkers of success in CL discomfort (CLD) management. METHODS Symptomatic CL wearers (CLDEQ-8 ≥ 12) were refitted (V1) with daily disposable CLs (Delefilcon A). After one month (V2), participants were classified into the post-fitting non-symptomatic (CLDEQ <12) and symptomatic (CLDEQ ≥12) groups. At each visit, the participants were clinically evaluated, tears were collected, and 20 inflammatory mediators and substance P (SP) were measured using multiplex immunobead analysis and ELISA, respectively. The detection rates and concentrations were compared between visits and groups, and logistic regression models were performed. RESULTS Forty-three subjects (32 women/11 men; mean age: 23.2 ± 4.9 years) were enrolled. The IL-1β and IL-9 detection rates were higher at V2 (p ≤ 0.044). The detection rates of IL-1β, IL-9, MIP-1α/CCL3, and MMP-9 at V1 (p ≤ 0.045) and IL-17A at V2 (p ≤ 0.014) were higher in the post-fitting symptomatic group. The tear IL-9 concentration was increased at V2 (p = 0.018). The tear concentrations of fractalkine/CX3CL1, IL-2, IL-6, IL-10, MCP-3/CCL7, MIP-1β, NGF, RANTES/CCL5, and TNF-α were higher in the post-fitting symptomatic group (p ≤ 0.044). Additionally, levels of fractalkine/CX3CL1, IL-2, IL-6, IL-10, RANTES/CCL5, and TNF-α at V1 were significantly associated with the post-fitting grouping (p ≤ 0.044). CONCLUSIONS Low tear concentrations of specific inflammatory mediators may be used as a predictive biomarker of success for refitting symptomatic CL wearers with daily disposable CLs. However, complementary treatments might be required for symptomatic CL wearers with higher levels of these inflammatory molecules.
Collapse
Affiliation(s)
- Andrés Ángel Calderón-García
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
- Universidad Católica de Ávila, Ávlia, Spain
| | - Alberto López-de la Rosa
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
- Department of Theoretical Physics, Atomic and Optics, Universidad de Valladolid, Valladolid, Spain
| | - Laura Valencia-Nieto
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
- Department of Theoretical Physics, Atomic and Optics, Universidad de Valladolid, Valladolid, Spain
| | - Carmen García-Vázquez
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
| | | | - Alberto López-Miguel
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
| | - Marta Blanco-Vázquez
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
- Department of Theoretical Physics, Atomic and Optics, Universidad de Valladolid, Valladolid, Spain
| | - Andrea Novo-Diez
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
- Department of Theoretical Physics, Atomic and Optics, Universidad de Valladolid, Valladolid, Spain
| | - Itziar Fernández
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
- Networking Research Center on Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| | - Amalia Enríquez de Salamanca
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
- Networking Research Center on Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| | - María Jesús González-García
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
- Department of Theoretical Physics, Atomic and Optics, Universidad de Valladolid, Valladolid, Spain
- Networking Research Center on Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| |
Collapse
|
2
|
Richards J, Rickert M, Carr K, Meyer D, Kollbaum P. The association between participant-reported ratings of comfort, dryness and vision quality in soft contact lens wearers. Ophthalmic Physiol Opt 2024; 44:693-703. [PMID: 38404148 DOI: 10.1111/opo.13292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 01/24/2024] [Accepted: 02/08/2024] [Indexed: 02/27/2024]
Abstract
INTRODUCTION Previous literature has indicated an association between participant-reported perceptions (e.g., ratings) of comfort, dryness and vision quality during soft contact lens wear. However, these reports do not account for participant- and lens-specific factors which may impact the interpretation of these results. The purpose of this project was to quantify the association between these participant-reported ratings while accounting for both participant- and lens-specific factors. METHODS Participant-reported ratings (scale 0-100) of comfort, dryness and quality of vision for 675 soft contact lens wearers (1207 eyes) were aggregated across 31 studies completed at Indiana University. Linear mixed-effects regression modelling was performed on each outcome rating individually. Covariate-adjusted models incorporated both participant- (e.g., age, sex) and lens-related (e.g., lens material, edge and optics) factors. The models were statistically adjusted for the duration of lens wear in hours and cumulative days of exposure. RESULTS Consistent with estimates from covariate-adjusted regression models, pairwise Spearman correlations [95% CI] between dryness and comfort (rs = 0.71, [0.69, 0.74]), vision quality and comfort (rs = 0.53, [0.49, 0.57]) and vision quality and dryness (rs = 0.49, [0.42, 0.54]) were all positive and had p < 0.001. Average participant-reported ratings of comfort, dryness and vision quality decreased by (bs [95% CI]) = -0.81 [-1.15, -0.46] -0.34 [-0.67, 0.0005] and -0.90 [-1.19, -0.60] rating units, respectively, for each hour of lens wear. CONCLUSIONS Significant positive associations were found between participant-reported measures of comfort, dryness and vision quality during soft contact lens wear. The associations between these ratings and the participant- and lens-related factors that drive them should be considered by clinicians and manufacturers when fitting and designing soft contact lenses.
Collapse
Affiliation(s)
- Josh Richards
- Indiana University School of Optometry, Bloomington, Indiana, USA
| | - Martin Rickert
- Indiana University School of Optometry, Bloomington, Indiana, USA
| | - Kenzie Carr
- Indiana University School of Optometry, Bloomington, Indiana, USA
| | - Dawn Meyer
- Indiana University School of Optometry, Bloomington, Indiana, USA
| | - Pete Kollbaum
- Indiana University School of Optometry, Bloomington, Indiana, USA
| |
Collapse
|
3
|
Maldonado-Codina C, Navascues-Cornago M, Smith SL, Read ML, Lakkis C, Morgan PB. End-of-day assessment of asymptomatic versus highly symptomatic soft contact lens wearers. Ophthalmic Physiol Opt 2024; 44:704-717. [PMID: 38546401 DOI: 10.1111/opo.13305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 03/08/2024] [Accepted: 03/10/2024] [Indexed: 05/01/2024]
Abstract
PURPOSE To investigate differences in key clinical parameters between asymptomatic and highly symptomatic soft contact lens (CL) wearers after 14 h of wear. METHODS In this pilot investigation, Phase 1 identified asymptomatic (CLDEQ-8 score ≤ 7) and highly symptomatic (CLDEQ-8 score ≥ 20) subjects after fitting with nelfilcon A CLs. Phase 2 investigated the following over a single nelfilcon A CL-wearing day (14 ± 2 h): blinking characteristics, tear meniscus height (TMH), non-invasive tear break-up time (NIBUT), tear film osmolarity and eyelid margin staining. Parameters for the two groups were compared using linear mixed models and post-hoc testing. The relationship between comfort scores and the clinical parameters was also investigated. RESULTS Overall, 161 and 42 subjects were enrolled into Phase 1 and 2, respectively. Twenty-five asymptomatic and 17 symptomatic subjects completed Phase 2. Lower eyelid TMH was decreased after 14 h in symptomatic compared with asymptomatic subjects (least square mean [LSM] difference -0.04 mm, 95% CI: -0.07, -0.01). Osmolarity was lower in symptomatic than in asymptomatic subjects at fitting (LSM difference -9.89, 95% CI: -18.91, -0.86). Upper eyelid margin staining was greater after 14 h in symptomatic than in asymptomatic subjects (LSM difference 0.53, 95% CI: 0.01, 1.05) and greater after 14 h than baseline in the symptomatic group (LSM difference 0.61, 95% CI: 0.16, 1.07). There was a significant relationship between comfort and upper eyelid margin staining (r = -0.40, 95% CI: -0.63, -0.11) and blink rate (r = -0.31, 95% CI: -0.57, -0.003). CONCLUSION The potential parameters most effective in differentiating asymptomatic from symptomatic wearers were upper eyelid margin staining and lower TMH. The parameter with the strongest relationship to comfort was upper eyelid margin staining, where higher comfort scores were associated with lower levels of staining.
Collapse
Affiliation(s)
- Carole Maldonado-Codina
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Maria Navascues-Cornago
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Sarah L Smith
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Michael L Read
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Carol Lakkis
- Johnson & Johnson Vision Care, Inc., Jacksonville, Florida, USA
- iBiomedical Consulting Pty Ltd, Melbourne, Victoria, Australia
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| |
Collapse
|
4
|
Lievens C, Pucker AD, Rayborn E, Kannarr S, Bickle K, Hogan C, Franklin QX, Christensen M. Refitting contact lens dropouts into a modern daily disposable contact lens. Ophthalmic Physiol Opt 2024; 44:686-692. [PMID: 38433496 DOI: 10.1111/opo.13299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 02/15/2024] [Accepted: 02/21/2024] [Indexed: 03/05/2024]
Abstract
PURPOSE To determine the number of previous contact lens (CL) wearers who could be comfortably refitted into delefilcon A (DAILIES TOTAL1®) CLs. METHODS This was a 6-month, three-visit study that recruited subjects who discontinued CLs within the past 2 years because of discomfort or dryness symptoms. Subjects were required to have Standard Patient Evaluation of Eye Dryness (SPEED) questionnaire scores ≤3 and to be able to wear spherical study CLs. Subjects were asked to complete a ±50 comfort visual analogue scale (VAS) at 1 month and a Likert questionnaire after 1 and 6 months of CL wear to understand the subjects' CL experience. RESULTS All 60 subjects who were fitted with the study CLs were still wearing them after 1 month, while one subject had dropped out by 6 months. Subjects had a median (interquartile range) age of 24.0 (7.0) years (71.7% female). They reported a median VAS score of 44.0 (8.0) units at the 1-month visit, with all reporting a comfortable score. At the 1-month/6-month visits, 98.3%/93.2%, 86.5%/78.0% and 93.2%/91.5% of subjects responded that they were very satisfied or satisfied with their vision, their end-of-day CL comfort and overall CL comfort, respectively. The same subjects responded that they were very likely or likely to continue to wear the study CLs at 1 (89.6%) and 6 months (80.7%) and to recommend the study CLs to a friend at 1 (98.3%) and 6 months (93.2%). CONCLUSIONS The results suggest that when encountering a CL dropout, a practitioner could educate a patient about trying an alternative CL and consider delefilcon A lenses as an option.
Collapse
Affiliation(s)
- Chris Lievens
- Southern College of Optometry, Memphis, Tennessee, USA
| | - Andrew D Pucker
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Elyse Rayborn
- Southern College of Optometry, Memphis, Tennessee, USA
| | | | | | | | - Quentin X Franklin
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | | |
Collapse
|
5
|
VanDerMeid KR, Byrnes MG, Millard K, Scheuer CA, Phatak NR, Reindel W. Comparative Analysis of the Osmoprotective Effects of Daily Disposable Contact Lens Packaging Solutions on Human Corneal Epithelial Cells. Clin Ophthalmol 2024; 18:247-258. [PMID: 38292853 PMCID: PMC10825585 DOI: 10.2147/opth.s437841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 12/12/2023] [Indexed: 02/01/2024] Open
Abstract
Purpose Contact lens (CL) wear challenges the balance of the ocular surface environment by increasing water evaporation and tear osmolarity. Maintaining ocular surface homeostasis during CL wear remains a goal of lens manufacturers and an important consideration for eye care professionals. The purpose of this study was to measure the metabolic activity and inflammatory responses of a transformed human corneal epithelial cell (THCEpiC) line under hyperosmotic conditions in the presence of CL packaging solutions. Methods CL packaging solutions sampled from seven daily disposable silicone hydrogel CL blister packages were prepared at 25% and made hyperosmolar (400 mOsm/kg) with NaCl. THCEpiCs were incubated with each solution for 24 hr, after which cell culture supernatants were collected. THCEpiC metabolic activity was determined by an alamarBlue assay. Concentrations in cell culture supernatants of inflammatory cytokine (interleukin [IL]-6) and chemokine (IL-8), as well as monocyte chemoattractant protein-1 (MCP-1), were quantitated by specific enzyme-linked immunosorbent assays. Results THCEpiC metabolic activity under hyperosmolar conditions decreased in the presence of somofilcon A and senofilcon A solutions (p=0.04 and 0.004, respectively), but no other solution (all p≥0.09). Concentrations of IL-6 increased in the presence of delefilcon A, somofilcon A, narafilcon A, and senofilcon A solutions (all p≤0.001), but no other solution (all p≥0.08), while those of IL-8 increased in the presence of all solutions (all p≤0.03) but kalifilcon A (p>0.99), and those of MCP-1 increased in the presence of delefilcon A, verofilcon A, somofilcon A, and stenfilcon A solutions (all p<0.0001), but no other solution (all p>0.99). Conclusion CL packaging solutions differ in their capacity to inhibit epithelial inflammation. THCEpiC inflammatory response was less in the presence of a CL packaging solution containing osmoprotectants than in solutions lacking osmoprotectants under moderately hyperosmolar conditions in vitro. Clinical studies are warranted to further substantiate the benefit of osmoprotectants.
Collapse
|
6
|
Costa D, De Matteis V, Treso F, Montani G, Martino M, Rinaldi R, Corrado M, Cascione M. Impact of the physical properties of contact lens materials on the discomfort: role of the coefficient of friction. Colloids Surf B Biointerfaces 2024; 233:113630. [PMID: 37956592 DOI: 10.1016/j.colsurfb.2023.113630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/31/2023] [Accepted: 11/01/2023] [Indexed: 11/15/2023]
Abstract
Contact Lens Discomfort (CLD) is the main cause in contact lens (CLs) discontinuation, referred in literature as drop-out phenomenon. Despite such evidence was reported in several clinical studies, a relationship between physico-chemical properties of CLs and CLD is not still totally understood. In this regard, the friction of CLs surfaces seems to be related to discomfort feeling events, probably due to an alteration of the lubricate function of the tear film after the CL placement inside the ocular environment. In the last years, many studies have been finalized to the friction measurements of CLs surface, finding conflicting data due to a lack in standardized protocol. The aim of this review is primarily to show evident relationships between CLs surface properties (i.e. wettability, tear evaporation, tear film quality, etc.) and the coefficient of friction (CoF), resulting therefore the most relevant physical quantity in the CLs characterization. In addition, we reported the most recent studies in CLs tribology, which highlight that the introduction of a standard protocol in CoF measurements is necessary to obtain reproducible results, considering the aim to evaluate in a more precise way the relationship between this material surface property and comfort in CLs users.
Collapse
Affiliation(s)
- D Costa
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - V De Matteis
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy.
| | - F Treso
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - G Montani
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - M Martino
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - R Rinaldi
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy
| | - M Corrado
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - M Cascione
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy.
| |
Collapse
|
7
|
Misu N, Mimura T, Noma H, Shinbo K. Patient Satisfaction and Tear Film Break-Up Time After First-Time Wearing of Silicone Hydrogel Contact Lenses. Cureus 2024; 16:e52516. [PMID: 38371096 PMCID: PMC10874256 DOI: 10.7759/cureus.52516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/18/2024] [Indexed: 02/20/2024] Open
Abstract
PURPOSE The dryness and discomfort associated with soft contact lenses (SCLs) prevent their continued use. Recently, verofilcon A, a new daily disposable silicone hydrogel material SCL, was introduced, which has a high water content (surface water content of 80% or more) that overcomes the low water content drawback of silicone hydrogels. In this study, we evaluated the non-invasive tear break-up time (NIBUT) and comfort level in individuals wearing verofilcon A SCL for the first time. METHODS We enrolled 42 first-time SCL wearers, comprising 84 eyes. NIBUT was measured using the DR-1α® dry eye observation device at the state of the naked eye before SCL wear (baseline) and at one and four weeks after the first SCL wear. Additionally, we conducted a questionnaire survey during the fourth week to assess the comfort level (0-10) of SCL wear. Results: The NIBUT values were significantly higher at one week (10.8 ± 2.2 s, p<0.01) and four weeks (11.4 ± 2.2 s, p<0.01) after the first SCL wear than those at baseline (5.9 ± 2.0 s). Comfort level in SCL use was significantly higher at one week (9.0 ± 1.1, p<0.01) and four weeks (8.7 ± 1.2, p<0.01) than that at baseline (7.8 ± 1.8), and this level was higher regardless of the baseline NIBUT value. CONCLUSION Prolonged BUT and increased comfort levels were observed in individuals wearing verofilcon A SCLs. Improvement in tear fluid retention was found to alleviate dry eye and discomfort, suggesting that verofilcon A may be a beneficial introductory lens for first-time SCL wearers.
Collapse
Affiliation(s)
- Naoko Misu
- Ophthalmology, Teikyo University School of Medicine, Tokyo, JPN
| | - Tatsuya Mimura
- Ophthalmology, Teikyo University School of Medicine, Tokyo, JPN
| | - Hidetaka Noma
- Ophthalmology, Hachioji Medical Center, Tokyo Medical University, Hachioji, JPN
| | | |
Collapse
|
8
|
Vianya-Estopa M, Ghorbani-Mojarrad N, Huntjens B, Garcia-Porta N, Piñero DP, Nagra M, Terry L, Dutta D, Wolffsohn J, Joshi M, Martin E, Maldonado-Codina C. Current approaches to soft contact lens handling training - Global perspectives. Cont Lens Anterior Eye 2023; 46:102068. [PMID: 37919220 DOI: 10.1016/j.clae.2023.102068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 10/03/2023] [Accepted: 10/18/2023] [Indexed: 11/04/2023]
Abstract
PURPOSE All neophyte contact lens wearers require training on how to handle contact lenses. Currently, almost no published information exists describing the most common approaches used by those involved in such training in soft contact lens wearers. This study aimed to gather information on the approaches taken by those conducting this training worldwide. METHODS An online survey was created in English and translated to Spanish and distributed internationally via social media, conference attendees, and professional contacts. The anonymous survey included information on workplace setting of respondents, information about the typical approaches used for application and removal of soft contact lenses, length of the appointment, and success rate with their approach. Survey responses were received between May 2021 and April 2022. RESULTS A total of 511 individuals completed the survey and responses were received from 31 countries with 48.7% from the UK. The most common approach taught for application was to have the patient hold the upper eyelashes (84.7%) and to hold the lower eyelid with the same hand as the lens (89.4%). Lenses were applied directly to the cornea by 57.7% of the respondents. The most common approach taught for lens removal was to drag the lens inferiorly from the cornea prior to removal (49.3%). Most respondents did not use videos to aid the teaching appointment (62.0%); however, they felt that their approach was successful in most cases (90). Application and removal training sessions lasted a median of 30 min and contact lenses were typically dispensed after the instructor witnessing successful application and removal three times. CONCLUSION Various methods are adopted globally for training of application and removal of soft contact lenses, with many advising a patient-specific approach is required for success. The results of this survey provide novel insights into soft contact lens handling training in clinical practice.
Collapse
Affiliation(s)
- Marta Vianya-Estopa
- Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, United Kingdom.
| | - Neema Ghorbani-Mojarrad
- School of Optometry and Vision Sciences, University of Bradford, Bradford, United Kingdom; Wolfson Centre for Applied Health Research, Bradford Royal Infirmary, Bradford, United Kingdom
| | - Byki Huntjens
- Centre for Applied Vision Research, School of Health Sciences, City University of London, London, United Kingdom
| | - Nery Garcia-Porta
- Department of Applied Physics. Faculty of Optics and Optometry. University of Santiago de Compostela, Spain; Institute of Materials of the University of Santiago de Compostela (iMATUS), Spain
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, Faculty of Science, University of Alicante, Alicante, Spain
| | - Manbir Nagra
- Vision and Eye Research Institute, Anglia Ruskin University, Cambridge, United Kingdom
| | - Louise Terry
- School of Optometry and Vision Sciences, Cardiff University, Cardiff, United Kingdom
| | - Debarun Dutta
- School of Health & Life Sciences, Aston University, Birmingham, United Kingdom
| | - James Wolffsohn
- School of Health & Life Sciences, Aston University, Birmingham, United Kingdom
| | - Mahesh Joshi
- School of Health Professions, University of Plymouth, Plymouth, United Kingdom
| | - Eilidh Martin
- Department of Vision Sciences, Glasgow Caledonian University, Glasgow, United Kingdom
| | | |
Collapse
|
9
|
Ghorbani-Mojarrad N, Rountree L, Terry L, Bruce H, Hallam E, Jolly L, Retallic N, Evans K. Clinical Investigation of Flat Pack Toric Contact Lenses and Wearer Attitudes to Environmental Impact. Eye Contact Lens 2023; 49:475-482. [PMID: 37707468 PMCID: PMC10589431 DOI: 10.1097/icl.0000000000001031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/27/2023] [Indexed: 09/15/2023]
Abstract
OBJECTIVES To investigate the performance of a novel flat pack toric daily disposable contact lens compared with traditionally packaged toric lenses in a randomized, crossover study. Environmental attitudes to contact lens wear were also explored. METHODS Habitual contact lens wearers were recruited to wear a hioxifilcon A (Miru 1 day Flat Pack Toric, Menicon, Nagoya, Japan) test lens and a control lens: either nelfilcon A (Dailies AquaComfort Plus, Alcon, Geneva, Switzerland) or etafilcon A (1-Day Acuvue Moist, Johnson & Johnson, New Brunswick, NJ). Objective lens performance was assessed at fitting, and participants wore lenses in a randomized order for three consecutive days. Subjective measures of lens performance (comfort, vision, and handling) were then assessed by a questionnaire, with further questions on overall lens preference and environmental perceptions. RESULTS Objective measures of lens fit were similar for the test and control lenses, except for distance VA which was better with the control lenses ( P <0.05; difference of two logMAR letters). End of day comfort was greater with the test lens, but this did not reach significance. Both lenses demonstrated similar scores for overall satisfaction. 87.5% of participants indicated the environmental impact of contact lenses to be important/extremely important to them, with 100% of participants identifying the flat pack packaging as having a smaller environmental impact. CONCLUSION Overall, the lenses used in the study performed to similar levels. Environmental credentials are important to contact lens wearers, which may contribute to overall lens preference.
Collapse
Affiliation(s)
- Neema Ghorbani-Mojarrad
- School of Optometry and Vision Sciences (K.E., L.T.), Cardiff University, Cardiff, United Kingdom; School of Optometry and Vision Science (H.B., E.H., L.J., L.R., N.G.-M.), University of Bradford, Bradford, United Kingdom; Menicon UK Ltd (N.R.), Northampton, United Kingdom; and Wolfson Centre for Applied Health Research (N.G.-M.), Bradford, United Kingdom
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Schulze MM, Fadel D, Luensmann D, Ng A, Guthrie S, Woods J, Jones L. Evaluating the Performance of Verofilcon A Daily Disposable Contact Lenses in a Group of Heavy Digital Device Users. Clin Ophthalmol 2023; 17:3165-3176. [PMID: 37901285 PMCID: PMC10612504 DOI: 10.2147/opth.s429250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 10/16/2023] [Indexed: 10/31/2023] Open
Abstract
Purpose The purpose of this study was to evaluate the performance of verofilcon A daily disposable contact lenses (CL) in CL wearers who identified themselves as heavy digital device users. Patients and Methods This prospective, non-masked, open-label study enrolled CL wearers who reported ≥6 hours digital device use per day. Participants were dispensed with the verofilcon A study lenses for 14±2 days, to be worn for at least 5 days a week and 10 hours per day, while continuing their normal routine of digital device use. Participants rated the lens performance at the Day 14 visit using a 0-100 (with 100 being best) scale. Ratings were completed at lens insertion, after 6 hours of digital device use, just before CL removal and for overall experience. Participants also completed a 4-point (strongly agree/disagree, slightly agree/disagree) Likert scale-based questionnaire. Results Thirty-two participants were eligible and completed the study (27 females; age 25.8 ± 6.0 years, ranging from 19 to 40). Overall lens performance ratings at the Day 14 visit (mean ± standard deviation) for comfort, dryness, and clarity of vision were 91 ± 11, 88 ± 11, and 92 ± 9, respectively. Subjective ratings were stable throughout the day with no significant differences after insertion, after 6 hours of digital device use and before CL removal (all p>0.05). The majority of participants agreed that the study lenses performed well, provided good all-day comfort (28/32; p<0.01) and good all-day vision (29/32; p<0.01). Participants also agreed that after ≥6 hours of digital device use they were satisfied with CL comfort (27/32; p<0.01), vision (29/32; p<0.01) and that the lenses provided good performance (26/32; p<0.01). Conclusion Verofilcon A lenses were found to perform well, with high ratings for comfort, dryness and vision that remained high throughout the day, during extensive digital device use.
Collapse
Affiliation(s)
- Marc-Matthias Schulze
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Daddi Fadel
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Doerte Luensmann
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Alison Ng
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Sarah Guthrie
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Jill Woods
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| |
Collapse
|
11
|
Chan KY, Chen C. YouTube as a learning source for contact lens insertion and removal. Clin Exp Optom 2023:1-6. [PMID: 37848190 DOI: 10.1080/08164622.2023.2259918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 09/12/2023] [Indexed: 10/19/2023] Open
Abstract
CLINICAL RELEVANCE Contact lens neophytes often learn about contact lens insertion and removal through YouTube videos of unknown quality. BACKGROUND This study evaluates the quality of soft contact lens insertion and removal videos on YouTube. METHODS A search for the keywords 'Contact lens insertion', 'Contact lens removal', 'Put in contact lens', and 'Take off contact lens' was performed on YouTube. The first 50 videos for each keyword were evaluated. The number of views, source of the publisher, days since upload, and video quality were scored based on the content in the videos. The maximum score of insertion and removal videos were 7 and 5 respectively. The videos were classified into three groups by publisher category: videos published by eye care professionals, companies and YouTubers. RESULTS Only 45 contact lens insertion and 44 removal videos met the inclusion criteria and were analysed. Insertion and removal videos published by YouTubers had the highest view and view rate. However, their quality scores were significantly lower than videos published by eye care professionals and companies. Videos uploaded by companies had the highest scores (insertion: 5.00 ± 1.10; removal: 3.25 ± 0.75). The mean scores of insertion and removal videos published by YouTubers were 1.65 ± 0.93 and 1.00 ± 0.89, respectively, while the insertion and removal videos uploaded by eye care professionals scored 3.58 ± 2.07 and 2.75 ± 1.53, respectively. There was also a negative correlation between the quality scores and view rate (p = 0.008, r = -0.41). CONCLUSION Contact lens insertion and removal videos uploaded by YouTubers had the highest view rate but the lowest quality. Videos made by companies included most essential elements.
Collapse
Affiliation(s)
- Ka Yin Chan
- Centre for Eye and Vision Research (CEVR), Hong Kong Science Park, Hong Kong, China
| | - Connie Chen
- Department of Optometry, Chung Shan Medical University, Taichung City, Taiwan, China
| |
Collapse
|
12
|
Morgan OA, Mirza AA, Parmar KR, Plowright AJ, Vega JA, Orsborn GN, Maldonado-Codina C, Whitehead JC, Morgan PB. Clinical performance and Willingness To Pay for soft toric contact lenses in low and moderate astigmats. Cont Lens Anterior Eye 2023; 46:101887. [PMID: 37460374 DOI: 10.1016/j.clae.2023.101887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 05/11/2023] [Accepted: 06/28/2023] [Indexed: 09/12/2023]
Abstract
PURPOSE To determine clinical performance and the 'Willingness To Pay' for toric vs. spherical soft contact lenses in an astigmatic population. METHODS In the clinical study, subjects with binocular low to moderate astigmatism (-0.75DC to -1.50DC) wore pairs of soft toric (Biofinity toric) and spherical (Biofinity) contact lenses in random sequence. Visual acuity (high and low contrast, monocular and binocular), subjective comfort and subjective vision were recorded. In the economics study, first subjects who had participated in the clinical study were presented with a series of randomised economic scenarios in order to determine their Willingness To Pay a premium (i.e. an increase) for toric lenses. Then, a similar set of scenarios were presented to a much larger group of online respondents and again, Willingness To Pay was established. RESULTS For the four measures of visual acuity, the Biofinity toric lens out-performed the Biofinity spherical lens by 0.6 to 1.1 lines.. Subjective vision performance was statistically significantly better with the toric lens for the distance task only. Comfort scores were not significantly different. Similar findings for Willingness To Pay were established for the clinical subjects and for the online respondents. The Willingness To Pay premium (additional fee) for a monthly supply of toric lenses (over spherical lenses) was between £13 and £16, if a toric lens provides better vision and similar comfort, as shown in the clinical study. CONCLUSION Consumers are willing to pay a monthly premium of around 50% to benefit from the typical experience of better vision and similar comfort for toric vs. spherical lenses. The level of additional cost for toric lenses compared to their spherical equivalents is less than this in the market, so eye care professionals should consider that toric lenses are delivering a greater clinical return than anticipated by wearers for the relatively small increase in price.
Collapse
Affiliation(s)
- O Ashton Morgan
- Department of Economics, Appalachian State University, Boone, NC 28608, United States
| | - Aftab A Mirza
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Oxford Rd, Manchester M13 9PL, United Kingdom
| | - Ketan R Parmar
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Oxford Rd, Manchester M13 9PL, United Kingdom
| | - Andrew J Plowright
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Oxford Rd, Manchester M13 9PL, United Kingdom
| | - Jose A Vega
- CooperVision Incorporated, 6101 Bollinger Canyon Rd, Suite 500, San Ramon, CA 94583, United States
| | - Gary N Orsborn
- CooperVision Incorporated, 6101 Bollinger Canyon Rd, Suite 500, San Ramon, CA 94583, United States
| | - Carole Maldonado-Codina
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Oxford Rd, Manchester M13 9PL, United Kingdom
| | - John C Whitehead
- Department of Economics, Appalachian State University, Boone, NC 28608, United States
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Oxford Rd, Manchester M13 9PL, United Kingdom.
| |
Collapse
|
13
|
Haworth K, Travis D, Leslie L, Fuller D, Pucker AD. Silicone hydrogel versus hydrogel soft contact lenses for differences in patient-reported eye comfort and safety. Cochrane Database Syst Rev 2023; 9:CD014791. [PMID: 37724689 PMCID: PMC10507745 DOI: 10.1002/14651858.cd014791.pub2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/21/2023]
Abstract
BACKGROUND Ocular discomfort is the leading cause of permanent discontinuation of soft contact lens (SCL) wear. Silicone hydrogel and hydrogel materials are the two major categories of SCLs, with silicone hydrogel materials being newer and more breathable than hydrogel materials. Whether comfort is associated with SCL material is controversial despite numerous studies. Similarly, the difference between these materials in terms of safety outcomes (e.g. frequency of microbial keratitis) is unclear. OBJECTIVES To evaluate the comparative effectiveness and safety of silicone hydrogel compared with hydrogel SCLs on self-reported comfort, dry eye test results, and adverse events in SCL-wearing adults 18 years of age or older. SEARCH METHODS The Cochrane Eyes and Vision Information Specialist searched the electronic databases for randomized controlled trials (RCTs). There were no restrictions on language or date of publication. We searched the Cochrane Central Register of Controlled Trials (CENTRAL, including the Cochrane Eyes and Vision Trials Register; 2022, Issue 6), MEDLINE Ovid, Embase.com, PubMed, LILACS (Latin American and Caribbean Health Science Information database), ClinicalTrials.gov, and World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP). We also searched the reference lists of identified studies, review articles, and guidelines for information about relevant studies that may not have been identified by our search strategy. Furthermore, we contacted investigators regarding ongoing trials. The most recent database search was conducted on 24 June 2022. SELECTION CRITERIA Our search selection criteria included RCTs, quasi-RCTs, and cross-over RCTs. DATA COLLECTION AND ANALYSIS We applied standard Cochrane methodology. MAIN RESULTS We included seven parallel-group RCTs conducted in the USA, the UK, Australia, Germany, India, and Turkey. A total of 1371 participants were randomized. The duration of SCL wear ranged from one to 52 weeks. Study characteristics and risk of bias The median number of participants per trial was 120 (interquartile range: 51 to 314), and the average age ranged from 20.7 to 33.0 years. Women represented the majority of participants (range 55% to 74.9%; 5 RCTs). Collectively, the included trials compared eight different silicone hydrogel SCLs with three different hydrogel SCLs. Five trials compared daily disposable SCLs, and two compared extended wear SCLs (worn for seven days and six nights). New SCL wearers were enrolled in three trials. Two trials included both new and established SCL wearers, and two trials did not report participants' history of SCL use. Five trials were sponsored by industry. We judged the overall risk of bias to be 'high' or 'some concerns' for the safety and efficacy outcomes. Findings One trial reported Ocular Surface Disease Index (OSDI) results, with the evidence being very uncertain about the effects of SCL material on OSDI scores (mean difference -1.20, 95% confidence interval [CI] -10.49 to 8.09; 1 RCT, 47 participants; very low certainty evidence). Three trials reported visual analog scale comfort score results, with no clear difference in comfort between materials, but the evidence was of very low certainty; trial results could not be combined because the three trials reported results at different time points. The evidence is very uncertain about the effect of SCL material on discontinuation of contact lens wear (risk ratio [RR] 0.64, 95% CI 0.11 to 3.74; 1 RCT, 248 participants). None of the included trials reported Contact Lens Dry Eye Questionnaire (CLDEQ-8) or Standard Patient Evaluation of Eye Dryness (SPEED) scores. There was no evidence of a clinically meaningful difference (> 0.5 unit) between daily disposable silicone hydrogel and hydrogel SCLs in corneal staining, conjunctival staining, or conjunctival redness (very low certainty evidence). Adverse events Very low certainty evidence from two trials comparing daily disposable SCLs suggested no evidence of a difference between lens materials in the risk of vision-threatening adverse events at one to four weeks (RR 0.68, 95% CI 0.08 to 5.51; 2 RCTs, 368 participants). Two trials comparing extended wear SCLs indicated that hydrogel SCLs may have a 2.03 times lower risk of adverse events at 52 weeks compared with silicone hydrogel SCLs (RR 2.03, 95% CI 1.38 to 2.99; 815 participants), but the certainty of evidence was very low. AUTHORS' CONCLUSIONS The overall evidence for a difference between all included silicone hydrogel and hydrogel SCLs was of very low certainty, with most trials at high overall risk of bias. The majority of studies did not assess comfort using a validated instrument. There was insufficient evidence to support recommending one SCL material over the other. For extended wear, hydrogel SCL may have a lower risk of adverse events at 52 weeks compared to silicon hydrogel. Future well-designed trials are needed to generate high certainty evidence to further clarify differences in SCL material comfort and safety.
Collapse
Affiliation(s)
| | - Darian Travis
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Louis Leslie
- Department of Ophthalmology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Daniel Fuller
- Cornea Contact Lens Service, The Eye Center, Southern College of Optometry, Memphis, TN, USA
| | - Andrew D Pucker
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| |
Collapse
|
14
|
Zhu Q, Zhang Q, Fu DY, Su G. Polysaccharides in contact lenses: From additives to bulk materials. Carbohydr Polym 2023; 316:121003. [PMID: 37321708 DOI: 10.1016/j.carbpol.2023.121003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/26/2023] [Accepted: 05/07/2023] [Indexed: 06/17/2023]
Abstract
As the number of applications has increased, so has the demand for contact lenses comfort. Adding polysaccharides to lenses is a popular way to enhance comfort for wearers. However, this may also compromise some lens properties. It is still unclear how to balance the variation of individual lens parameters in the design of contact lenses containing polysaccharides. This review provides a comprehensive overview of how polysaccharide addition impacts lens wear parameters, such as water content, oxygen permeability, surface wettability, protein deposition, and light transmittance. It also examines how various factors, such as polysaccharide type, molecular weight, amount, and mode of incorporation into lenses modulate these effects. Polysaccharide addition can improve some wear parameters while reducing others depending on the specific conditions. The optimal method, type, and amount of added polysaccharides depend on the trade-off between various lens parameters and wear requirements. Simultaneously, polysaccharide-based contact lenses may be a promising option for biodegradable contact lenses as concerns regarding environmental risks associated with contact lens degradation continue to increase. It is hoped that this review will shed light on the rational use of polysaccharides in contact lenses to make personalized lenses more accessible.
Collapse
Affiliation(s)
- Qiang Zhu
- School of Pharmacy, Nantong University, Nantong 226001, China
| | - Qiao Zhang
- Department of Clinical Pharmacy, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China
| | - Ding-Yi Fu
- School of Pharmacy, Nantong University, Nantong 226001, China
| | - Gaoxing Su
- School of Pharmacy, Nantong University, Nantong 226001, China.
| |
Collapse
|
15
|
Trosan P, Tang JSJ, Rosencrantz RR, Daehne L, Smaczniak AD, Staehlke S, Chea S, Fuchsluger TA. The Biocompatibility Analysis of Artificial Mucin-Like Glycopolymers. Int J Mol Sci 2023; 24:14150. [PMID: 37762451 PMCID: PMC10532372 DOI: 10.3390/ijms241814150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 09/05/2023] [Accepted: 09/08/2023] [Indexed: 09/29/2023] Open
Abstract
The ocular surface is covered by a tear film consisting of an aqueous/mucin phase and a superficial lipid layer. Mucins, highly O-glycosylated proteins, are responsible for lubrication and ocular surface protection. Due to contact lens wear or eye disorders, lubrication of the ocular surface can be affected. Artificial glycopolymers which mimic natural mucins could be efficient in ophthalmic therapy. Various neutral, positively, and negatively charged mucin-mimicking glycopolymers were synthesized (n = 11), cultured in different concentrations (1%, 0.1%, and 0.01% w/v) with human corneal epithelial cells (HCE), and analyzed by various cytotoxicity/viability, morphology, and immunohistochemistry (IHC) assays. Six of the eleven glycopolymers were selected for further analysis after cytotoxicity/viability assays. We showed that the six selected glycopolymers had no cytotoxic effect on HCE cells in the 0.01% w/v concentration. They did not negatively affect cell viability and displayed both morphology and characteristic markers as untreated control cells. These polymers could be used in the future as mucin-mimicking semi-synthetic materials for lubrication and protection of the ocular surface.
Collapse
Affiliation(s)
- P. Trosan
- Department of Ophthalmology, University Medical Center Rostock, 18057 Rostock, Germany
| | - J. S. J. Tang
- Biofunctionalized Materials and (Glyco) Biotechnology, Fraunhofer Institute for Applied Polymer Research IAP, 14476 Potsdam, Germany
| | - R. R. Rosencrantz
- Biofunctionalized Materials and (Glyco) Biotechnology, Fraunhofer Institute for Applied Polymer Research IAP, 14476 Potsdam, Germany
- Institute of Materials Chemistry, Chair of Biofunctional Polymer Materials, Brandenburg University of Technology BTU, 01968 Senftenberg, Germany
| | - L. Daehne
- Surflay Nanotec GmbH, 12489 Berlin, Germany
| | | | - S. Staehlke
- Department of Ophthalmology, University Medical Center Rostock, 18057 Rostock, Germany
| | - S. Chea
- Biofunctionalized Materials and (Glyco) Biotechnology, Fraunhofer Institute for Applied Polymer Research IAP, 14476 Potsdam, Germany
| | - T. A. Fuchsluger
- Department of Ophthalmology, University Medical Center Rostock, 18057 Rostock, Germany
| |
Collapse
|
16
|
Rueff EM. Visual discomfort and contact lens wear: A review. Cont Lens Anterior Eye 2023; 46:101872. [PMID: 37277259 DOI: 10.1016/j.clae.2023.101872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 05/22/2023] [Accepted: 05/30/2023] [Indexed: 06/07/2023]
Abstract
The purpose of this manuscript is to describe how vision influences contact lens discomfort and review the evidence supporting the hypothesis that contact lens discomfort can be caused by vision and vision-related disorders. Contact lens discomfort is a misunderstood and difficult to manage clinical condition. Most treatments and strategies aimed at alleviating discomfort focus on optimizing the contact lens fit and its relationship with the ocular surface, but these strategies commonly fail at relieving discomfort symptoms. Many vision and vision-related disorders share symptoms with those reported by uncomfortable contact lens wearers. This paper will review evidence and literature that describes how these vision and vision-related disorders may influence comfort in contact lens wearers. Acknowledging how vision influences contact lens discomfort will improve future research intended to better understand the condition, allow for more effective clinical management, and reduce rates of discontinuation.
Collapse
Affiliation(s)
- Erin M Rueff
- The Southern California College of Optometry at Marshall B Ketchum University, 2575 Yorba Linda Blvd, Fullerton, CA 92831, USA.
| |
Collapse
|
17
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
18
|
Call T, Pucker AD, McGwin G, Franklin QX, Logan A. Real-Time Ocular Comfort Reporting in Monthly Replacement Contact Lens Wearers. CLINICAL OPTOMETRY 2023; 15:97-103. [PMID: 37181863 PMCID: PMC10167961 DOI: 10.2147/opto.s403319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 04/29/2023] [Indexed: 05/16/2023]
Abstract
Purpose To map contact lens (CL) comfort over the full wear day and across 1 month's wear in established, asymptomatic to minimally symptomatic, reusable, soft CL wearers. Methods Adult, 18- to 45-year-old, participants were recruited and required to have 20/20 best-corrected visual acuity or better and must have been asymptomatic to minimally symptomatic CL wearers. Participants were required to be able to wear TOTAL30® sphere CLs and have minimal astigmatism. Participants were fit in the study CLs and asked to wear these CLs daily for the next month for 16 hours per day each day. Participants were asked to complete a visual analog scale (VAS) survey via text message at time of CL application and after 8, 10, 12, 14, and 16 hours of wear and at CL removal on days 1, 2, 3, 4, and 5 and at 2 weeks and 1 month. The utilized VAS had a ±50 scale with positive scores being comfortable, negative scores being uncomfortable, and scores of 0 being neutral comfort. Results Forty-eight participants were recruited who had a mean ± SD age of 26.2 ± 5.2 years (71% female). Mean initial VAS CL comfort scores at initial CL dispense were 45.56 ± 9.20 units. Mean CL wear times for any of the days evaluated were at least 14.80 ± 2.41 hours per day and did not differ across the study (p = 0.77). Mean comfort VAS scores significantly decreased over the wear day (all days p ≤ 0.02), yet there were no significant differences in VAS comfort scores across the same time of day for the duration of the study (all times p ≥ 0.06). Conclusion This study determined that while CL wearers were slightly less comfortable at the end of the day compared to application, this comfort change was minimal given that the average participants had overwhelmingly good comfort at all time-points evaluated. Comfort scores were likewise consistent across 1 month of wear.
Collapse
Affiliation(s)
- Terri Call
- Department of Optometry and Vision Science, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Andrew D Pucker
- Department of Optometry and Vision Science, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Gerald McGwin
- Department of Epidemiology, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Quentin X Franklin
- Department of Optometry and Vision Science, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Amy Logan
- Department of Optometry and Vision Science, University of Alabama at Birmingham, Birmingham, AL, USA
| |
Collapse
|
19
|
Morgan PB, Sulley AL. Challenges to the new soft contact lens wearer and strategies for clinical management. Cont Lens Anterior Eye 2023; 46:101827. [PMID: 36935225 DOI: 10.1016/j.clae.2023.101827] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 01/10/2023] [Accepted: 03/05/2023] [Indexed: 03/19/2023]
Abstract
Soft contact lens discontinuations have a dramatic impact on the overall success of this form of vision correction, and evidence suggests that the reasons for contact lens cessation are different for new wearers than for established lens users. In descending order, these relate to vision, discomfort, handling, inconvenience/loss of interest, ocular health and cost. This paper considers the background and underlying evidence for these causes of soft lens discontinuation in new wearers, and presents clinical management strategies to minimise this phenomenon. Such measures can reasonably be expected to significantly reduce the number of contact lens discontinuations leading to happier patients, increased satisfaction for eye care professionals (ECPs), and greater success for both individual practices and the contact lens industry more broadly.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, Manchester M13 9PL, England.
| | | |
Collapse
|
20
|
Orthokeratology in adults and effect on quality of life. Cont Lens Anterior Eye 2023; 46:101824. [PMID: 36898875 DOI: 10.1016/j.clae.2023.101824] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 02/19/2023] [Accepted: 02/20/2023] [Indexed: 03/12/2023]
Abstract
OBJECTIVE To determine changes in various ocular parameters of adults wearing orthokeratology (ortho-k) lenses and their levels of satisfaction and quality of life (QoL) after commencing treatment. METHODS Adults aged 18-38 years, with mild to moderate myopia and astigmatism < 1.50D, were wearing ortho-k lenses for one year. Data collection, which included history taking, refraction, axial length (AL), corneal topography, corneal biomechanics, and biomicroscopy examination, was performed at baseline and every 6 months during the study period. The level of satisfaction with the treatment and QoL was determined via questionnaires. RESULTS Forty-four subjects completed the study. AL was shortened significantly at the 12-month visit: AL -0.03 (-0.45 to 0.13) mm compared to baseline (p < 0.05). A significant number of subjects in both groups presented with overall and central corneal staining, but the majority were mild (Grade 1). Central endothelial cell density was reduced by 40/mm2 (loss rate 1.4 %) (p < 0.05). High scores were obtained in the satisfaction questionnaire, with no significant differences between visits. At the 12-month visit, NEI-RQL-42 total score, dependence on correction, activity limitation, appearance, and satisfaction with the treatment all significantly increased compared to baseline values. CONCLUSIONS Results suggest that ortho-k can be an effective and safe myopia correction technique for adults with low to moderate myopia, improving daytime vision without serious adverse events. Satisfaction with ortho-k lens wear was high, particularly those who were dependent on vision correction and found spectacles or contact lenses limiting specific activities or cosmetically undesirable.
Collapse
|
21
|
Cho P, Boost MV, Cheung SW. Ocular signs and symptoms of orthokeratology patients associated with povidone iodine-based disinfecting solution. Cont Lens Anterior Eye 2023; 46:101742. [PMID: 35931598 DOI: 10.1016/j.clae.2022.101742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 07/15/2022] [Accepted: 07/18/2022] [Indexed: 01/18/2023]
Abstract
PURPOSE To determine the frequency and severity of ocular symptoms and signs in new orthokeratology (ortho-k) subjects using a povidone iodine (PI) disinfecting system compared to those present before lens wear, and whether these were associated with cleaning regimes. METHODS This study recruited 80 subjects from two myopia control studies, who used a PI disinfecting solution for routine use. Ocular symptoms and signs at baseline, one- and six-month after lens wear were reported via questionnaires and ocular examination, respectively. To determine if rates of occurrence were attributable to differences in cleaning regime, subjects were randomly assigned into four groups with respect to routine care procedures, which involved various combinations of rubbing and use of a daily and/or enzymatic cleaner. RESULTS Sixty-eight subjects completed all aspects of the study. As there were no significant differences in incidence of signs and symptoms between the four groups before and after lens wear (Friedman tests, p > 0.07), data were combined for further analysis. Prior to lens wear, itchiness (69 %) and dryness (53 %) were the most commonly reported symptoms. The frequency and severity of all symptoms remained similar after lens wear (p > 0.10). Presence of follicles in the lower tarsal conjunctiva (22 %) and conjunctival injection (15 %) was frequently observed, but reduced significantly after lens wear (p < 0.01). Mild corneal staining, noted in 13 % of subjects at baseline, did not change significantly over time (p = 0.17). Ocular signs were not necessarily reflected in symptoms and vice versa. CONCLUSION Use of a PI-based solution did not increase the frequency or severity of ocular signs and symptoms observed before lens wear. Absence of a difference in occurrence of ocular discomfort with respect to cleaning regimes indicated that the use of the PI-based solution may adequately clean the lenses over a 6-month period.
Collapse
Affiliation(s)
- Pauline Cho
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong Special Administrative Region
| | - Maureen Valerie Boost
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong Special Administrative Region
| | - Sin Wan Cheung
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong Special Administrative Region.
| |
Collapse
|
22
|
McMonnies CW. Why are soft contact lens wear discontinuation rates still too high? EXPERT REVIEW OF OPHTHALMOLOGY 2022. [DOI: 10.1080/17469899.2022.2160321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Charles W McMonnies
- Faculty of Medicine and Health, School of Optometry and Vision Science, University of New South Wales, Northbridge, Australia
| |
Collapse
|
23
|
McParland M, Walsh K, Comoroda D, Sulley A. Wearer Experience and Eye Care Professional Acceptance with a 1 Day Multifocal Contact Lens. CLINICAL OPTOMETRY 2022; 14:223-235. [PMID: 36444271 PMCID: PMC9700463 DOI: 10.2147/opto.s375133] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 10/18/2022] [Indexed: 06/16/2023]
Abstract
PURPOSE A large observational survey was undertaken to determine eye care professional (ECP) and patient experience of stenfilcon A multifocal soft contact lens (MyDay multifocal) when prescribed in a real-world setting. METHODS A total of 196 ECPs from eleven countries fit up to ten presbyopes with stenfilcon A multifocal. Data were collected on fit success at the initial visit, patient satisfaction with comfort, vision at distance, intermediate, and near, overall vision, overall satisfaction, and handling at the initial and follow-up visits after 1-2 weeks of wear. ECPs completed questionnaires on multifocal fitting experience and expectations before and after the fitting period. RESULTS A total of 196 pre-fitting and 141 post-fitting ECP surveys were collected. A total of 1505 initial fits (mean age 53.4, range 38 to 81 years, 73% female, 27% neophytes) and 1440 follow-up visits were completed. The mean distance vision contact lens prescription was -1.32DS (range -12.00DS to +8.00DS) with Add powers: Low 56%, Medium 24%, and High 21%. At the follow-up visit 77% (n=1108) of trials were successful. Mean patient satisfaction ratings (1-10 scale, where 1 is not at all satisfied, and 10 extremely satisfied) at the initial visit were higher than eight out of ten for comfort, vision, and overall satisfaction, and were not significantly different after 1-2 weeks of wear. Stenfilcon A multifocal was preferred by 66% of patients over their habitual correction. In most cases mean satisfaction scores and the proportion of patients highly satisfied were not significantly different between myopes and hyperopes, across Add range, between new and habitual wearers, and wearers of frequently replaced and 1 day contact lenses. CONCLUSION ECPs in real-world clinical settings found stenfilcon A multifocal contact lenses easy to fit to a wide range of patients, with a high fit success rate and high levels of patient satisfaction for overall comfort, vision, satisfaction, and handling.
Collapse
Affiliation(s)
| | - Karen Walsh
- Coopervision, Inc. Professional Affairs, San Ramon, CA, USA
| | - Daniel Comoroda
- Lumanity (Formerly Cello Health Insight), Insight Department, Bethesda, MD, USA
| | - Anna Sulley
- Coopervision, Inc. Medical Affairs, San Ramon, CA, USA
| |
Collapse
|
24
|
Gustafson B, Whaley S, Giedd B, Montaquila S, Edwards B, Subbaraman LN. Short-Term Fit Assessment of a Novel Daily Disposable, Toric, Silicone Hydrogel Contact Lens. Clin Ophthalmol 2022; 16:3721-3730. [PMID: 36407500 PMCID: PMC9673940 DOI: 10.2147/opth.s370151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 10/19/2022] [Indexed: 11/16/2022] Open
Abstract
Purpose The development of new contact lens materials and designs are necessary to minimise patient dropout. A lens material with water surface technology was recently developed to incorporate toric design. The on-eye stability of a toric contact lens is critical to a successful toric lens fitting. In an effort to establish if the new daily disposable verofilcon A toric silicone hydrogel lens provides fast stability for ease of fit, this study assessed the initial and short-term on-eye stability of this new lens. Patients and Methods Habitual full-time wearers of soft contact lenses, aged 18 or over, were enrolled and fit with the verofilcon A toric lens. Study endpoints included lens settling time, axis orientation at specific time-points within 10 minutes after insertion, lens oscillation with blink, lens movement and centration, and scribe mark visibility. Results Thirty-nine subjects completed the study; 67% were female and mean age was 34.1 ± 10.8 years (range 18 to 61). The majority of verofilcon A toric lenses (98.7%) settled on average within 60 seconds. Average lens orientation was 3° from six o’clock position within two minutes of insertion. The lenses showed minimal oscillation with blink; 98.7% of the eyes demonstrated ≤5° oscillation with blink. All lenses showed optimal/acceptable lens movement and centration and the scribe mark was reported as easily visible in 96% of eyes. Practitioners reported a 99% first lens fit success rate. Conclusion The novel verofilcon A toric lens was highly successful with the first lens, had excellent on-eye stability and good fit characteristics. These qualities make this new lens a good option for lens wearers. Furthermore, it fulfills the needs of practitioners who want a toric lens that is easy and predictable to fit.
Collapse
Affiliation(s)
| | | | | | | | | | - Lakshman N Subbaraman
- Alcon Research, LLC, Johns Creek, GA, USA
- Correspondence: Lakshman N Subbaraman, Alcon Research, LLC, Clinical Development & Medical Affairs, Johns Creek, GA, 30097, USA, Tel +1 678 415 5316, Email
| |
Collapse
|
25
|
Fogt JS, Patton K. Evaluation of Wear Experience with Soft Daily Disposable Lenses for Astigmatism over 16 Hours of Wear. CLINICAL OPTOMETRY 2022; 14:207-214. [PMID: 36329952 PMCID: PMC9624167 DOI: 10.2147/opto.s387740] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2022] [Accepted: 10/18/2022] [Indexed: 05/28/2023]
Abstract
OBJECTIVE The purpose of this study was to assess the wear experience of participants while wearing a toric daily disposable contact lens with water surface technology over long days of lens wear. METHODS Existing soft toric contact lens wearers were fit with the daily disposable study lenses. Participants assessed their initial comfort, vision, and satisfaction with the lenses by visual analog scale (VAS) survey. After a successful 1-week follow-up visit, participants were scheduled for 5 survey days, in which surveys were deployed to their smartphones for immediate assessments of comfort and quality of vision on a 1-10 scale at 10, 12, 14, and 16 hours of lens wear on 5 subsequent weeknights. The final study visit assessed visual acuity, and overall lens wear experience surveys were completed with VAS surveys. The overall median and interquartile (IQR) range of all surveys were calculated. RESULTS Thirty bilateral toric lens wearers completed the study. Median (IQR) initial impression VAS scores were 97(12) for quality of vision, 100(9) for comfort, and 96(10) for satisfaction. Median evening surveys resulted in comfort scores of 10(1) at 10 hours, 9(2) at 12 hours, 9(2) at 14 hours, and 8(2) at 16 hours of wear. Median evening surveys resulted in quality of vision scores of 10(1) at 10 hours, 10(2) at 12 hours, 9(2) at 14 hours, and 9(3) at 16 hours of wear. VAS scores for overall experience were 97(9) for comfort, 95(13) for vision, and 8(31) for dryness. End-of-day VAS scores were 93(21) for comfort, 90(15) for vision, and 21(38) for dryness. Mean (±standard deviation) OU LogMAR visual acuity with the study lenses was -0.19(0.06). CONCLUSION Surveys of wear experience resulted in high scores for comfort and vision over the course of a long day of wear with the daily disposable study lenses in this population of patients with astigmatism.
Collapse
Affiliation(s)
| | - Kimberly Patton
- College of Optometry, The Ohio State University, Columbus, OH, USA
| |
Collapse
|
26
|
Waghmare SV, Jeria S. A Review of Contact Lens-Related Risk Factors and Complications. Cureus 2022; 14:e30118. [PMID: 36381898 PMCID: PMC9644230 DOI: 10.7759/cureus.30118] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 10/10/2022] [Indexed: 11/05/2022] Open
Abstract
The purpose of this article is to develop a modern strategy for handling difficulties related to contact lenses and their care. A growing number of people throughout the world are currently concerned by eye-related undesirable activities in allergy sufferers and those wearing contact lenses. While many wearers who experience ocular discomfort exhibit dryness as a symptom, many other contact lens-related pain symptoms also include irritation and fatigue, and managing coexisting diseases must be done in accordance with aspects of wearing contact lenses, all of which undoubtedly increase discomfort. It is typical for contact lens storage containers to have persistent microbial contamination, which has been linked to microbial keratitis (MK) and clear corneal invasion. Contact lens-associated MK is an interesting, potentially sight-threatening complexity arising from wearing soft contact lenses. Estimates show that for every 10,000 persons who wear contact lenses each year, there are 2 to 5 occurrences of MK. Investigating separate determinants for contact lens-associated MK and evaluating their impact on infection load is one of the challenges in their administration. It is hoped that this will offer a useful outline of the complicated issues of contact lens wear that are both infectious and non-infectious. Recent epidemiological studies detailing the risk factors associated with contact lens use, and the effect of pathogen and individual immune profiles on the severity of diseases have enlightened how we might interpret the prophylaxis and prevention of contact lens-related corneal infection. The most dreaded side effect of contact lens use, infectious keratitis linked with contact lenses, will be reviewed, along with the most recent advancements in its diagnosis and treatment.
Collapse
|
27
|
Differences in Practitioner Experience, Practice Type, and Profession in Attitudes Toward Growing Contact Lens Practice. Eye Contact Lens 2022; 48:369-376. [PMID: 35971228 DOI: 10.1097/icl.0000000000000920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/12/2022] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To investigate eye care practitioners' attitudes and perceptions toward potential interventions that can enhance contact lens (CL) practice across the world, and how this is influenced by their practice setting. METHODS A self-administered, anonymized survey was constructed in English and then forward and backward translated into six more languages. The survey was distributed online via social media platforms and mailing lists involving reputed international professional bodies. RESULTS In total, 2,222 responses from 27 countries with sufficient responses were analyzed (53% females, median age- 37 years). Most of the respondents were optometrists (81.9%) and 47.6% were from stand-alone/independent practices. Median working experience in CL prescribing was 11.0 years (IQR: 18.0, 4-22 years). Over two-third of them declared themselves to be very hopeful (22.9%) or hopeful (45.1%) about the future of their CL practice. Among the potential interventions proposed, continuous update of knowledge and skills and competently managing CL-related complications were rated the most important (median score: 9/10 for each). Practitioners working in national/regional retail chains expressed higher proactivity in recommending CLs (9/10) than those in local chains, hospitals, and universities (for all 8/10, P<0.05). National differences were also identified in eye care practitioner attitudes and perceptions (P<0.05). CONCLUSIONS The study provided important information to delineate a variety of elements characterizing CL practice across the world. These insights can serve as a basis to design strategies at national and international levels.
Collapse
|
28
|
Jiang H, Fang M, Franklin R, Simms AG, Fadli Z, Wang J. Associations Between Lid Wiper Microvascular Responses, Lens Fit, and Comfort After One Day of Contact Lens Adaptation by Neophytes. Eye Contact Lens 2022; 48:340-346. [PMID: 35580543 PMCID: PMC9329170 DOI: 10.1097/icl.0000000000000898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/29/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE To determine associations between lid wiper microvascular responses, lens fit, and comfort after 1 day of contact lens adaptation by neophytes. METHODS Functional slitlamp biomicroscopy was used to image the microvascular network of the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva. Fractal dimension was obtained to represent vessel density. Ultra-high-resolution optical coherence tomography was used to image the lens edge and fitting characteristics, including lens movement and lens-induced conjunctival indentation. Ocular comfort was rated using a 50-point visual analogue scale (VAS). Forty-nine healthy subjects without a history of contact lens wear were recruited. A contact lens was then fitted in the right eye. Imaging was taken at baseline and 6 hr after lens wear. RESULTS The changes of VAS comfort score were negatively related to the changes of the vessel density in the lid-wiper (R 2 =0.18, P =0.002) and bulbar conjunctiva (R 2 =0.13, P =0.009). However, the changes of VAS were positively related to the changes in vessel density of the tarsal conjunctiva (R 2 =0.11, P =0.02). The changes of ocular microvasculature were not related to the objective metrics of the lens-fitting characteristics ( P >0.05). Similarly, the changes in the VAS comfort score were not related to the objective metrics of the lens-fitting characteristics ( P >0.05). CONCLUSION Contact lens discomfort seemed to relate to lid wiper microvascular responses rather than fitting characteristics after 1 day of contact lens adaptation by neophytes.
Collapse
Affiliation(s)
- Hong Jiang
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Department of Neurology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Min Fang
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Shenzhen Key Laboratory of Ophthalmology, Shenzhen Eye Hospital, Jinan University, Shenzhen, Guangdong, China
| | - Ross Franklin
- Johnson & Johnson Vision Care, Inc, Jacksonville, FL, USA
| | - Ava-Gaye Simms
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Zohra Fadli
- Johnson & Johnson Vision Care, Inc, Jacksonville, FL, USA
| | - Jianhua Wang
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| |
Collapse
|
29
|
Wesley G, Giedd B, Hines B, Bickle K, Pearson C, Lorentz H. Safety and Efficacy of a New Water Gradient Biomimetic Monthly Replacement Spherical Contact Lens Material (Lehfilcon A). Clin Ophthalmol 2022; 16:2873-2884. [PMID: 36065354 PMCID: PMC9440676 DOI: 10.2147/opth.s362926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 08/15/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose The objective of this study was to evaluate the safety and performance of the investigational lens, lehfilcon A, when worn in a daily wear modality and replaced monthly as compared to the commercially available comfilcon A contact lens. Methods This was a multicenter, prospective, controlled, double-masked, randomized, parallel-group clinical study with bilateral lens wear for 3 months. In all, 115 subjects completed the study (77 with test lehfilcon A and 38 with control comfilcon A contact lenses). Distance visual acuity (VA) was assessed using Snellen VA. Lens performance was assessed by examining lens fit/movement, centration, front surface wettability and front/back surface deposits using slit-lamp biomicroscopy. Results At the 3-month follow-up visit, all eyes had a distance VA of 20/20 or better. Further, lens fit/movement was assessed as optimal in 92.9% of the eyes with lehfilcon A and 89.2% with comfilcon A. There were no ratings of unacceptably tight or loose fits for either contact lens material. Lens centration was assessed as optimal in 98.7% of eyes with lehfilcon A and 94.6% with comfilcon A. For front and back surface deposits, both materials showed minimal lens surface deposits. Front surface wettability was assessed as grade 0 or 1 for most of the study lenses in both lens groups across all attended study visits. There were no ocular adverse events related to the study lenses. Conclusion Overall, lehfilcon A showed excellent VA, optimal lens fitting characteristics, a clean surface, high wettability, and low risk for adverse events after 3 months of lens wear.
Collapse
Affiliation(s)
| | - Brad Giedd
- Kindred Optics at Maitland Vision, Maitland, FL, USA
| | | | | | | | - Holly Lorentz
- Alcon Research, LLC, Johns Creek, GA, USA
- Correspondence: Holly Lorentz, Alcon Research, LLC, 11460 Johns Creek Pkwy, Johns Creek, GA, 30097, USA, Tel +1 678 415 5272, Email
| |
Collapse
|
30
|
Fogt JS, Patton K. Long Day Wear Experience with Water Surface Daily Disposable Contact Lenses. CLINICAL OPTOMETRY 2022; 14:93-99. [PMID: 35860307 PMCID: PMC9292054 DOI: 10.2147/opto.s367891] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 07/05/2022] [Indexed: 05/28/2023]
Abstract
OBJECTIVE The purpose of this study was to assess the wear experience of silicone hydrogel daily disposable contact lenses with water surface technology over a long day of lens wear. METHODS Thirty-five soft contact lens wearers were refit with the daily disposable study lenses and participants scored their initial impressions of comfort, vision and satisfaction using a visual analog scale (VAS). Participants used their smart phones to complete surveys of comfort and vision on a scale of 1-10 at 10, 12, 14, and 16 hours of lens wear on 5 weeknights. A participant score for each time point was calculated by averaging the evening responses. End of study VAS surveys of symptoms were also completed. RESULTS Median (Interquartile Range) VAS initial impression scores were 99.00 (12.00) for quality of vision, 98.00 (16.00) for comfort, and 100.00 (13.00) for satisfaction. The end of study surveys found end of day median VAS scores of 87.00 (19.00) for end of day quality of vision and 75.00 (24.50) for end of day comfort. The median score for overall quality of vision was 93.00 (14.00) and for overall comfort was 93.00 (16.50). The median score for end of day dryness was 37.00 (55.00) and overall dryness was 13.00 (34.00). CONCLUSION The daily disposable lenses with water surface treatment used in this study maintained high median scores for comfort and quality of vision for up to 16 hours of wear.
Collapse
Affiliation(s)
| | - Kimberly Patton
- College of Optometry, The Ohio State University, Columbus, OH, USA
| |
Collapse
|
31
|
Rojas-Viñuela J, Frogozo MJ, Piñero DP. What we know about the scleral profile and its impact on contact lens fitting. Clin Exp Optom 2022:1-14. [PMID: 35817407 DOI: 10.1080/08164622.2022.2097858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
Scleral contact lens fitting has provided practitioners with one of the earliest pieces of evidence that the sclera was more often asymmetric than symmetric. Some preliminary observations such as different haptic alignment patterns over the sclera in 360 degrees, the appearance of fogging in the fluid chamber and excessive tear out-in flow through specific meridians, quadrants, or areas of the haptic provide evidence of some scleral asymmetry. The advent of technologies that allowed measurement of the scleral profile led to formal research confirming that only about 6% of scleras are symmetric, while the rest are toric, quad-specific, or irregular. This has an evident impact on how to focus scleral lens fitting. Measuring the scleral profile also provided us with true ocular sagittal height data for cord diameters beyond the cornea. Although high variability was expected in pathological eyes, healthy eyes also showed a wide range of ocular sagittal heights. Due to this variability among healthy eyes, a discussion has emerged on whether the one-size-fits-all approach to soft lens fitting is a proper strategy to fit the whole spectrum of sagittal heights. The traditional mode of selecting the parameters for custom soft lenses through corneal parameters is also questioned.
Collapse
Affiliation(s)
| | - Melanie J Frogozo
- Alamo Eye Care - The Contact Lens Institute of San Antonio, San Antonio, Texas, USA
| | - David P Piñero
- Alamo Eye Care - The Contact Lens Institute of San Antonio, San Antonio, Texas, USA.,Department of Ophthalmology, Vithas Medimar International Hospital, Alicante, Spain.,Department of Optics, Pharmacology, and Anatomy, University of Alicante, Alicante, Spain
| |
Collapse
|
32
|
Nair AP, Sethu S, Nagaraj H, Kumar V, Nagaraj S, Fadli Z, Scales C, Chemaly M, Song XY, Ghosh A, Liang B. Ocular Surface Immune Cell Profiles in Contact Lens-Induced Discomfort. Transl Vis Sci Technol 2022; 11:16. [PMID: 35857328 PMCID: PMC9315072 DOI: 10.1167/tvst.11.7.16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose Contact lens–induced discomfort (CLD) remains a primary factor in discontinuation or prevention of contact lens wear. Thus, we investigated the role of ocular surface immune cells in subjects with CLD. Methods Habitual contact lens (CL) wearers with CLD (n = 19; 38 eyes) and without CLD (n = 21; 42 eyes) as determined by the Contact Lens Dry Eye Questionnaire-8 was included in a trial. Enrolled subjects used either of the two types of CL (designated as CL-A or CL-D). Ocular surface cells from the bulbar conjunctiva were obtained by impression cytology. The collected cells were phenotyped using fluorochrome-conjugated antibodies specific for leukocytes (CD45+), neutrophils (CD66b+,High,Low), macrophages (CD163+), T cells (CD3+CD4+, CD3+CD8+), natural killer (NK) cells (CD56+, High, Low), natural killer T (NKT) cells (CD3+CD56+), and gamma delta T (γδT) cells (CD3+γδTCR+) by flow cytometry. Further, corneal dendritic cell density (cDCD) was also determined using in vivo confocal microscopy. Results Significantly higher proportions of CD45+ cells were observed in subjects with CLD compared to those without CLD. The percentages of CD66bTotal,Low, CD163+, pan T cells, CD4+T cells, CD8+T cells, CD56Total,High,Low (NK) cells, and NKT cells, as well as the CD4/CD8 ratio, were significantly higher in CLD subjects. The proportion of T cells (CD4, CD8, CD4/CD8 ratio, NKT cells) and macrophages exhibited a direct association with discomfort score. The percentages of CD45+, CD66bTotal,Low, CD163+, CD3+, CD56Total,High,Low, and NKT cells and cDCD were significantly higher in CLD subjects wearing CL-D. The percentages of CD66bHigh, CD4+T cells, CD8+T cells, NKT cells, and CD4/CD8 ratio were significantly higher in CLD subjects wearing CL-A. Conclusions Increased proportions of ocular surface immune cells are observed in CLD, and the lens type could impact the immune cells associated with CLD. Translational Relevance The association between the proportion of altered ocular surface immune cell subsets and contact lens–induced discomfort underpins the importance of considering immune-related aspects during contact lens development and in the clinical management of ocular surface pain.
Collapse
Affiliation(s)
| | - Swaminathan Sethu
- GROW Research Laboratory, Narayana Nethralaya Foundation, Bangalore, India
| | - Harsha Nagaraj
- Department of Cornea and Refractive Surgery, Narayana Nethralaya, Bangalore, India
| | - Vijay Kumar
- Department of Cornea and Refractive Surgery, Narayana Nethralaya, Bangalore, India
| | - Sriharsha Nagaraj
- Department of Cornea and Refractive Surgery, Narayana Nethralaya, Bangalore, India
| | - Zohra Fadli
- Johnson & Johnson Vision, Jacksonville, FL, USA
| | | | | | | | - Arkasubhra Ghosh
- GROW Research Laboratory, Narayana Nethralaya Foundation, Bangalore, India
| | | |
Collapse
|
33
|
OSDI Questions on Daily Life Activities Allow to Detect Subclinical Dry Eye in Young Contact Lens Users. J Clin Med 2022; 11:jcm11092626. [PMID: 35566752 PMCID: PMC9101005 DOI: 10.3390/jcm11092626] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 04/29/2022] [Accepted: 05/02/2022] [Indexed: 02/05/2023] Open
Abstract
Dry eye disease (DED) is difficult to detect in young contact lens (CL) wearers, who usually have no signs, mild symptoms and an ocular surface disease index (OSDI) below the DED diagnosis values (OSDI ≥ 13). We investigate if some of the 12 OSDI questions (OSDI A—ocular symptoms; OSDI B—vision-related functionality; OSDI C—environmental triggers) contribute the most to classify young CL as symptomatic. TBUT and tear volume are also measured. Age, gender and refraction error-matched eye glasses (EG) wearers participated as the control. CL and EG data were compared with t-test and z-test. Confusion matrices and logistic correlation analyses were performed to define the contribution of each OSDI question to classify symptomatic subjects. OSDI classified symptomatic CL better than the tear volume or TBUT values. In CL, only OSDI B and C values were significantly higher in symptomatic vs. asymptomatic subjects (p < 0.001), while values of all twelve OSDI questions were significantly higher in symptomatic vs. asymptomatic EG (p < 0.05−0.001). All OSDI questions contribute equally to identify symptomatic EG, while only OSDI B questions on daily life visual functions are significant to classify symptomatic CL wearers at risk to develop DED or at a subclinical stage. CL wearers scoring ≥ 2 on the OSDI B questions should be considered for preventive treatments, even if their clinical sings are scarce or absent.
Collapse
|
34
|
Xu Y, Xu Z, Shu X, Liu Q, Wang Y, Xia J, Li Y, Qu J, Hu L. Dynamic Changes of Ocular Surface in First-Time Contact Lens Wearers and the Effective Factors of Contact Lens Discomfort. Front Med (Lausanne) 2022; 9:833962. [PMID: 35360725 PMCID: PMC8962650 DOI: 10.3389/fmed.2022.833962] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Accepted: 02/04/2022] [Indexed: 11/16/2022] Open
Abstract
Purpose The purpose of the study is to investigate the dynamic changes in ocular surface indicators in first-time contact lens (CL) wearers and identify the most influential factors in CL discomfort (CLD). Methods A total of 26 healthy non-CL wearers (26 eyes) were recruited and fitted monthly with disposable hydrogel CLs. Each participant underwent a full ocular surface evaluation, which include Efron grading, tear film breakup time, Schirmer's I test, corneal dendritic cell (DCs) imaging by in vivo confocal microscopy (IVCM), and conjunctival microvasculature evaluation by functional slit-lamp biomicroscopy. CLD was assessed using the Ocular Surface Disease Index questionnaire at baseline, 1 week, 1, 3, and 6 months after wearing it and another 6 months after discontinuing it. Results Clinical signs and CLD were significantly increased in the first week (p < 0.05). The microvascular response and DC activation peaked at the 1-month interval (p < 0.05). During CL wear, CLD is positively correlated with corneal staining (B = 0.238, p = 0.002), papillary conjunctivitis (B = 0.245, p < 0.001), and microvascular blood flow velocity (B = 0.353, p < 0.001). After discontinuation, only DC activation remained elevated at 6 months, whereas the other signs recovered. Conclusions The first week of CL wear was the main period for the appearance of ocular surface clinical signs, and the first month was the main period for the activation of subclinical inflammation. Corneal staining and conjunctival microvascular response are the main factors affecting CLD. Even if the clinical signs recover after discontinuing wear, subclinical inflammation may persist.
Collapse
Affiliation(s)
- Yangyang Xu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
- Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Zhiqiang Xu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Xupeng Shu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Qiaoli Liu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Yuzhou Wang
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Jiahui Xia
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Yong Li
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Jia Qu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
- *Correspondence: Liang Hu
| | - Liang Hu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
- Jia Qu
| |
Collapse
|
35
|
Guthrie S, Ng A, Woods J, Vega J, Orsborn G, Jones L. Exploring the factors which impact overall satisfaction with single vision contact lenses. Cont Lens Anterior Eye 2022; 45:101579. [PMID: 35246387 DOI: 10.1016/j.clae.2022.101579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 02/18/2022] [Accepted: 02/20/2022] [Indexed: 11/03/2022]
Abstract
PURPOSE To explore the impact of subjective factors (lens handling, comfort and vision) on overall single vision contact lens satisfaction. METHODS Correlation analysis of a prospective, randomised, double-masked, bilateral crossover study involving 55 adapted lens wearers fitted with somofilcon A (SiHy) (clariti® 1 day, CooperVision) and etafilcon A (Hy) (1 DAY ACUVUE® MOIST, Johnson & Johnson Vision) was conducted. Subjective ratings of lens handling, comfort and vision collected after 1 week of lens wear for each lens type were correlated with overall satisfaction. Data were analysed by combining data for both lens types and also for each lens separately. RESULTS For the combined analysis, significant correlations (p < 0.01) were found between subjective ratings of overall satisfaction and ratings of handing for application (r = 0.64), handling for removal (r = 0.50), comfort upon application (r = 0.59), comfort at end of day (r = 0.61), overall satisfaction with comfort (r = 0.88) and overall satisfaction with vision (r = 0.64). Correlation analysis of the per lens data showed that lens specific correlations of overall satisfaction with handling for lens application varied greatly with lens material (SiHy: r = 0.26, p = 0.05 vs Hy: r = 0.72, p < 0.01). Correlation strength of comfort upon application/at end of day with overall satisfaction also varied with lens material (Application: SiHy: r = 0.40 vs Hy: r = 0.61; End of day: SiHy: r = 0.76 vs Hy: r = 0.58; all p ≤ 0.01). CONCLUSION Overall satisfaction was significantly correlated with the specific subjective evaluations of handling, vision and comfort. Correlations of overall satisfaction and ease of handling for each lens type suggest that, for habitual contact lens wearers, dissatisfaction with handling at the time of lens application can play a major role in overall dissatisfaction with a lens. Handling for application had a similar correlation (r) value as vision, suggesting that handling for application should not be underestimated when considering overall patient satisfaction.
Collapse
Affiliation(s)
- Sarah Guthrie
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
| | - Alison Ng
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Jill Woods
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Jose Vega
- CooperVision Incorporated, 6101 Bollinger Canyon Rd, Suite 500, San Ramon, CA 94583, USA
| | - Gary Orsborn
- CooperVision Incorporated, 6101 Bollinger Canyon Rd, Suite 500, San Ramon, CA 94583, USA
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| |
Collapse
|
36
|
Bishop MJ, Sun CK, Coles-Brennan C, Gallois-Bernos A. Evaluation of daily disposable senofilcon A contact lenses in a symptomatic population. Cont Lens Anterior Eye 2022; 45:101574. [PMID: 35101386 DOI: 10.1016/j.clae.2022.101574] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 12/02/2021] [Accepted: 01/18/2022] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate the comfort performance of ACUVUE OASYS® 1-Day with HydraLuxe™ Technology among symptomatic contact lens wearers by using Contact Lens User Experience (CLUE) comfort scores and Contact Lens Dry Eye Questionnaire 8 (CLDEQ-8) discomfort and dryness scores. METHODS Three clinical trials evaluated comfort and dryness when refitting symptomatic contact lens wearers to ACUVUE OASYS® 1-Day with HydraLuxe™ lenses. This analysis combined the CLUE comfort and CLDEQ-8 scores obtained at baseline and 2-week follow-up and compared average scores between visits. Subjects were grouped by habitual lens modality (daily disposable or daily wear reusable) and habitual lens material (silicone hydrogel or hydrogel). The analysis included data from 107 subjects. RESULTS Significant increases in mean CLUE comfort scores between baseline and 2-week follow-up occurred in all subject groups across habitual lens modality and material, indicating an improvement in overall comfort. CLUE comfort score improved clinically (≥5-point increase) among 75.7% of subjects (81/107). Similarly, significant decrease in mean CLDEQ-8 scores between baseline and 2-week follow-up occurred in all subject groups, indicating a decrease in the prevalence of dryness and discomfort symptoms. CLDEQ-8 score improved clinically (≥3-point reduction) among 82.2% of subjects (88/107). A majority of subjects (57.0%) became asymptomatic (CLDEQ-8 score ≤ 11 points) after 2 weeks of bilateral wear. CONCLUSION Refitting symptomatic contact lens patients to ACUVUE OASYS® 1-Day with HydraLuxe™ can improve overall comfort and reduce symptoms of dryness and discomfort, irrespective of the previous lens modality or habitual lens material.
Collapse
Affiliation(s)
| | - Chung-Kai Sun
- Johnson & Johnson Vision, 7500 Centurion Parkway, Jacksonville, FL 32256, USA
| | | | | |
Collapse
|
37
|
Rutschilling R, Fogt JS. Wear Experience of a Water Surface Daily Disposable Contact Lens in Existing Silicone Hydrogel Planned Replacement Lens Wearers. CLINICAL OPTOMETRY 2022; 14:27-34. [PMID: 35281321 PMCID: PMC8904437 DOI: 10.2147/opto.s353666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/25/2021] [Accepted: 02/10/2022] [Indexed: 05/16/2023]
Abstract
PURPOSE The health benefits of silicone hydrogel lens materials and a daily replacement modality have been demonstrated in previous studies; however, existing planned replacement lens wearers may resist changing to a new lens replacement schedule. The purpose of this study is to evaluate the wear experience of satisfied planned replacement silicone hydrogel wearers when refit into a silicone hydrogel daily disposable lens. PATIENTS AND METHODS In this open-label, non-comparison study, satisfied wearers of two week planned replacement contact lenses were evaluated for inclusion criteria and refit with optimized prescriptions in their habitual lenses. At a follow-up visit one week later, participants were refit with the study daily disposable lenses and completed visual analog scale (VAS) surveys of initial quality of vision, comfort, and satisfaction. Participants returned for a final visit after two weeks of wearing the study daily disposable lenses. At the final visit, VAS surveys for both overall and end of day (EOD) vision, comfort, and dryness were completed. Overall median and interquartile range (IQR) were assessed for all surveys in the study. RESULTS Thirty individuals completed the study (29.1 ± 7.8 years old; 19 female). Median (IQR) results for the initial impression VAS surveys were 92.50(11.75) for quality of vision, 92.50(18.00) for comfort, and 93.00(18.00) for satisfaction. Final VAS survey results revealed median scores of 87.50(25.00) for EOD quality of vision and 82.50(51.25) for EOD comfort. The median overall quality of vision was 91.00(17.00) and overall comfort was 93.00(28.50). Median (IQR) overall dryness was 28.50(49.00) and median EOD dryness was 30.50(64.25). CONCLUSION The findings of this study suggest that providers can successfully refit satisfied wearers of early generation silicone hydrogel planned replacement lenses into a new generation silicone hydrogel daily disposable lens while maintaining satisfaction.
Collapse
Affiliation(s)
| | - Jennifer Swingle Fogt
- College of Optometry, The Ohio State University, Columbus, OH, USA
- Correspondence: Jennifer Swingle Fogt, College of Optometry, The Ohio State University, 338 W. 10th Ave, Columbus, OH, 43210, USA, Tel +1 614 292 0882, Email
| |
Collapse
|
38
|
Walsh K, Jones L, Moody K. Addressing common myths and misconceptions in soft contact lens practice. Clin Exp Optom 2021; 105:459-473. [PMID: 34886744 DOI: 10.1080/08164622.2021.2003693] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Advances in contact lens technology over the past 50 years since the commercialisation of the first soft lenses in 1971 have been incredible, with significant changes in contact lens materials, frequency of replacement, care systems and lens designs occurring. However, despite the widespread availability of contact lenses, penetration rates for those who need vision correction remain in the low single digits and many practitioners seem to hold on to concepts around the potential value of contact lenses that appear based in the dim and distant past and are certainly no longer valid today. This review addresses 10 common 'myths and misconceptions' around soft contact lenses using an evidence-based approach that can hopefully dispel some of these incorrect assumptions.
Collapse
Affiliation(s)
- Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.,Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Shatin, Hong Kong
| | - Kurt Moody
- Johnson & Johnson Vision, Jacksonville, Florida, USA
| |
Collapse
|
39
|
Shi Y, Jiang N, Bikkannavar P, Cordeiro MF, Yetisen AK. Ophthalmic sensing technologies for ocular disease diagnostics. Analyst 2021; 146:6416-6444. [PMID: 34591045 DOI: 10.1039/d1an01244d] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Point-of-care diagnosis and personalized treatments are critical in ocular physiology and disease. Continuous sampling of tear fluid for ocular diagnosis is a need for further exploration. Several techniques have been developed for possible ophthalmological applications, from traditional spectroscopies to wearable sensors. Contact lenses are commonly used devices for vision correction, as well as for other therapeutic and cosmetic purposes. They are increasingly being developed into ocular sensors, being used to sense and monitor biochemical analytes in tear fluid, ocular surface temperature, intraocular pressure, and pH value. These sensors have had success in detecting ocular conditions, optimizing pharmaceutical treatments, and tracking treatment efficacy in point-of-care settings. However, there is a paucity of new and effective instrumentation reported in ophthalmology. Hence, this review will summarize the applied ophthalmic technologies for ocular diagnostics and tear monitoring, including both conventional and biosensing technologies. Besides applications of smart readout devices for continuous monitoring, targeted biomarkers are also discussed for the convenience of diagnosis of various ocular diseases. A further discussion is also provided for future aspects and market requirements related to the commercialization of novel types of contact lens sensors.
Collapse
Affiliation(s)
- Yuqi Shi
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, UK.
| | - Nan Jiang
- West China School of Basic Medical Sciences and Forensic Medicine, Sichuan University, Chengdu 610041, China.
| | | | - M Francesca Cordeiro
- UCL Institute of Ophthalmology, London, UK.,ICORG, Imperial College London, London, UK
| | - Ali K Yetisen
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, UK.
| |
Collapse
|
40
|
Associations between Binocular Vision Disorders and Contact Lens Dissatisfaction. Optom Vis Sci 2021; 98:1160-1168. [PMID: 34678836 DOI: 10.1097/opx.0000000000001780] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE These data demonstrate that binocular vision disorders (BVDs) contribute to contact lens (CL) dissatisfaction independently of CL discomfort (CLD) in myopic, pre-presbyopic, adult, single-vision CL wearers. PURPOSE This study aimed to determine whether BVDs contribute to CL dissatisfaction and whether this contribution is independent of CLD. METHODS Participants attended one clinical visit while wearing their habitual CLs. Symptoms from CLD and BVDs were measured with the Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and Convergence Insufficiency Syndrome Survey (CISS), respectively. A comprehensive binocular vision (BV) assessment was performed. The Ocular Surface Disease Index (OSDI) was used to measure CL dissatisfaction from CLD and BVDs based on reported correlations between the CLDEQ-8 and the CISS with the OSDI. Participants were categorized according to their CL comfort status (CLD [≥12 on CLDEQ-8] or non-CLD [<12 on CLDEQ-8]) and BV status (BVD or non-BVD). RESULTS Seventy-six participants completed the trial, and 19 (25%) were diagnosed with BVD. Those diagnosed with BVD scored higher than did those diagnosed with non-BVD for the OSDI (25.1 ± 12.7 vs. 10.7 ± 7.3, P < .001) and CISS (18.7 ± 7.7 vs. 11.9 ± 5.9, P = .001), but not the CLDEQ-8 (P = .25). Those categorized as having CLD scored higher than did those categorized as having non-CLD for the OSDI (19.0 ± 12.3 vs. 9.3 ± 5.9, P = .003) and CISS (16.1 ± 6.8 vs. 11.0 ± 6.2, P = .001). There were no significant interactions between BV status and CL comfort status for any questionnaire (P > .08). CONCLUSIONS Higher scores for OSDI in those with CLD or BVD indicate that both conditions contribute to CL dissatisfaction. Higher scores for the CISS in those with CLD suggest a degree of overlap for some BVD symptoms. Nonsignificant differences between BVD and non-BVD for the CLDEQ-8 suggest that BVDs contribute to CL dissatisfaction independently of CLD.
Collapse
|
41
|
Using face masks with spectacles versus contact lenses. Cont Lens Anterior Eye 2021; 45:101516. [PMID: 34607768 DOI: 10.1016/j.clae.2021.101516] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 09/16/2021] [Accepted: 09/20/2021] [Indexed: 01/20/2023]
Abstract
PURPOSE To test the hypothesis that various subjective ocular and task-related parameters associated with wearing a face mask would be better in neophyte contact lens (CL) wear compared to habitual spectacle (Sp) wear. METHODS Thirty participants were randomised to continue in Sp (n = 15) or wear somofilcon A daily disposable CL (n = 15) ('group'). A surgical face mask (Type II R) was worn for at least one hour per day on four or more days per week. After two weeks, participants completed the Quality of Life Impact of Refractive Correction Questionnaire (QIRC), a two-part face mask usability questionnaire and graded ocular-related symptoms using 0-100 visual analogue scales. RESULTS There was no difference between groups for overall QIRC score but some individual question scores reflected better quality of life in the CL: 'outdoor activities', 'keep fit' and 'able to do things' (all p < 0.05). Differences in favour of the CL were seen for the following in the face mask usability questionnaire: 'breathing', 'heat', 'comfort on ears', 'overall comfort', 'walking', 'driving', 'reading', 'computer use', 'exercising' and 'socialising' (all p < 0.05). Significant differences were also seen for the 0-100 VAS symptoms probing vision quality in favour of the CL: glare, distance and near vision, fogging, restricted field of view and peripheral blur. CONCLUSION This work supports anecdotal reports that CL are a better vision correction option than Sp when used in conjunction with a face mask. Participants reported a range of benefits to the CL/face mask combination for vision-related symptoms, breathing and heat-related symptoms and a number of day-to-day activities including walking, driving and exercising. All of the benefits relating to the CL are likely to result in improved adherence to face mask use. Overall, the findings of this work suggest that where possible, CL should be the preferred vision correction option for people using face masks.
Collapse
|
42
|
Efron N, Morgan PB, Nichols JJ, Walsh K, Willcox MD, Wolffsohn JS, Jones LW. All soft contact lenses are not created equal. Cont Lens Anterior Eye 2021; 45:101515. [PMID: 34583895 DOI: 10.1016/j.clae.2021.101515] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 08/11/2021] [Accepted: 09/19/2021] [Indexed: 12/13/2022]
Abstract
Soft contact lenses that have been prescribed by eye care practitioners are sometimes substituted for alternative lenses by unqualified, unregulated and sometimes even fully regulated lens suppliers, in the mistaken belief that there is essentially no difference between different soft lens types. This review considers the implications of inappropriately substituting soft contact lens types in terms of (a) lens properties: surface treatment, internal wetting agents, material, total diameter, back optic zone radius, thickness, edge profile, back surface design, optical design, power, colour (tint) and ultraviolet protection; and (b) lens usage: wearing modality (daily versus overnight wear) and replacement frequency. Potential aspects of patient dissatisfaction and adverse events when prescribed soft lenses are substituted for lenses with different properties or intended usage are considered. Substitution of 15 of the 16 lens properties considered (i.e. except for back surface design) was found to be related to at least one - and as many as six - potential sources of patient dissatisfaction and adverse ocular events. Contact lens are medical devices which are prescribed and fitted; they should never be substituted for another lens type in the absence of a new prescription further to a full finalised fitting, for the simple reason that all soft contact lenses are not created equal. A substituted lens may have properties that results in undesirable consequences in respect of vision, ocular health, comfort and cosmetic appearance, and may be incompatible with the lifestyle of the patient.
Collapse
Affiliation(s)
- Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia.
| | - Phillip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Manchester, UK
| | - Jason J Nichols
- School of Optometry, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Mark D Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | | | - Lyndon W Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada; Centre for Eye and Vision Research (CEVR), Hong Kong
| |
Collapse
|
43
|
Fujimoto H, Ochi S, Yamashita T, Inoue Y, Kiryu J. Role of the Water Gradient Structure in Inhibiting Thin Aqueous Layer Break in Silicone Hydrogel-Soft Contact Lens. Transl Vis Sci Technol 2021; 10:5. [PMID: 34473222 PMCID: PMC8419878 DOI: 10.1167/tvst.10.11.5] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Purpose Soft contact lenses (SCLs) are effective for refractive error correction, but prolonged wear triggers discomfort and discontinuation. This study investigates whether water gradient technology of delefilcon A-based SCLs improve tear film dynamics. Methods This retrospective observational study included 50 asymptomatic delefilcon A or narafilcon A users. Data on thin aqueous layer break (TALB; %), noninvasive tear break-up time (NIBUT), tear meniscus height (TMH; mm), subjective dryness, and higher-order aberrations (HOAs) were collected. Measurements of the bare eye, the SCL-worn eye after 15 minutes (visit 1 [v1]) and 30 ± 5 days after v1 after SCL was worn for ≥5 hours (visit 2 [v2]) were recorded. Results TALB was significantly reduced in the delefilcon A group compared to the narafilcon A group (33.3% vs. 85.5% at v1; P < 0.0001 and 31.7% vs. 80.4% at v2; P < 0.0001). The NIBUT was also significantly higher in the former (4.2 ± 2.1 seconds vs. 2.9 ± 1.5 at v1; P < 0.01 and 4.1 ± 2.3 seconds vs. 2.7 ± 1.6 seconds at v2; P < 0.01) across both visits. The TMH was significantly reduced in the former in both v1 and v2. The total ocular HOAs were significantly lower in the former at v1 (P < 0.001) and v2 (P < 0.05) compared to the bare eye. Conclusions The water gradient technology of delefilcon A reduces TALB and increases NIBUT. Translational Relevance The use of water gradient technology improves tear film dynamics and alleviate pathological break-up pattern, improving lens performance.
Collapse
Affiliation(s)
- Hisataka Fujimoto
- Department of Ophthalmology, Kawasaki Medical School, Kurashiki, Okayama, Japan
| | | | | | | | - Junichi Kiryu
- Department of Ophthalmology, Kawasaki Medical School, Kurashiki, Okayama, Japan
| |
Collapse
|
44
|
Opportunities and threats to contact lens practice: A global survey perspective. Cont Lens Anterior Eye 2021; 44:101496. [PMID: 34426063 DOI: 10.1016/j.clae.2021.101496] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 06/11/2021] [Accepted: 07/26/2021] [Indexed: 12/14/2022]
Abstract
AIM To understand the views of contact lens (CL) practitioners across the globe regarding what they perceive as opportunities and threats in CL practice. METHODS A self-administered anonymised questionnaire, constructed in English and translated in six more languages, was distributed through reputed international professional bodies and academic institutions worldwide. The questionnaire included items on demographic characteristics, type of practice, and questions designed to explore practitioners' perspective on the future of their CL practice over the next five years. RESULTS A total of 2408 valid responses were analysed. Multifocal CLs for presbyopia, CLs for myopia control, use of daily disposable (DD) CLs for occasional wear, and biocompatible materials to improve comfort were identified as promising areas of opportunities by practitioners (all 8/10). Respondents from North America, and Europe valued DDCLs for occasional wear moderately more favourable (Median: 9/10 for all) as compared to colleagues in Asia (Median: 8/10, p < 0.001), South America (Median: 8/10, p < 0.01), and Africa (Median: 8/10p < 0.01). Multifocal CLs for presbyopia was perceived as a better opportunity by practitioners in North America and Europe (Median: 9/10 for both), as well as in Australasia (Median: 8/10), in comparison to Asia, Africa, and Middle East (for all Median: 6/10, p < 0.001). Practitioners expressed concerns about the availability of CLs and CL prescriptions online without direct professional involvement (both 9/10). CONCLUSIONS Overall, the most appealing opportunities for CL practice growth were identified in occasional use of DD CLs, biocompatible materials to reduce CL discomfort, multifocal CLs for presbyopia correction and management of myopia control with CLs. Lack of regulation in CL sales, especially online, seemed to be a constant threat. The insights from this study can be used to design targeted strategies to enhance CL practice across the globe and in specific geographical areas.
Collapse
|
45
|
Graham AD, Lin MC. The relationship of pre-corneal to pre-contact lens non-invasive tear breakup time. PLoS One 2021; 16:e0247877. [PMID: 34181641 PMCID: PMC8238214 DOI: 10.1371/journal.pone.0247877] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Accepted: 02/15/2021] [Indexed: 11/18/2022] Open
Abstract
Purpose To examine the relationship between pre-corneal and pre-contact lens tear film stability (TFS), and to determine whether pre-corneal TFS is a reliable predictor of subsequent pre-lens TFS after a contact lens is placed on the eye. Methods 667 records met inclusion criteria and were extracted from a soft contact lens multi-study database. Multivariable linear mixed effects models were fit to examine the association between pre-corneal and pre-lens TFS, adjusting for potential confounders and accounting for repeated measures. Receiver Operating Characteristic (ROC) analysis was employed to assess the predictive performance of pre-corneal TFS for subsequent pre-lens TFS. TFS was quantified for this analysis as the non-invasive tear breakup time (NITBUT). Results Pre-corneal NITBUT was significantly related to the pre-lens NITBUT at both 10 min (p<0.001) and 2–6 hrs (p<0.001) post-lens insertion. However, the sensitivities of pre-corneal NITBUT for predicting symptom-associated thresholds of pre-lens NITBUT ranged from 50–65%, and specificities ranged from 57–72%, suggesting poor-to-moderate diagnostic performance. Conclusions Despite the association of pre-corneal and pre-lens TFS, the inherent lability and sensitivity to environmental exposures of the tear film introduce significant variability into NITBUT measurements. Using pre-corneal NITBUT to identify likely successful contact lens candidates prior to fitting is thus not sufficiently accurate to be relied upon in the clinical setting.
Collapse
Affiliation(s)
- Andrew D. Graham
- Clinical Research Center, School of Optometry, University of California, Berkeley, California, United States of America
| | - Meng C. Lin
- Clinical Research Center, School of Optometry, University of California, Berkeley, California, United States of America
- Vision Science Group, University of California, Berkeley, California, United States of America
- * E-mail:
| |
Collapse
|
46
|
Fogt JS, Weisenberger K, Fogt N. Visual performance with multifocal contact lenses and progressive addition spectacles. Cont Lens Anterior Eye 2021; 45:101472. [PMID: 34049808 DOI: 10.1016/j.clae.2021.101472] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 05/14/2021] [Accepted: 05/23/2021] [Indexed: 11/03/2022]
Abstract
PURPOSE As presbyopia occurs, new visual demands create a need for clear vision at multiple distances. Many spectacle wearers adapt into progressive addition lenses (PAL) in order to see clearly at distance, intermediate, and near. A multifocal contact lens provides the ability to see at these same distances without the prismatic effects of a spectacle lens or the peripheral obstruction of a spectacle frame. No studies have been done to date comparing the effect of these types of presbyopic vision correction on a variety of tests of visual performance representative of everyday tasks. METHODS A battery of visual performance tasks were completed by subjects while wearing their habitual PAL spectacles. These subjects were then fit with a multifocal contact lens and wore lenses for 2 weeks or more before completing the tasks again. These functional vision tests included assessments of coincidence anticipation timing, peripheral search and hand-eye coordination, and dynamic visual acuity. Following functional vision testing, subjects completed a preference survey comparing both types of refractive correction while performing common activities of daily living. RESULTS Performance on the majority of the tests of visual performance were equivalent (P < 0.05) when comparing PAL spectacles and multifocal contact lenses. Survey results demonstrated a preference for multifocal contact lenses overall. CONCLUSION PAL spectacles are widely prescribed for presbyopic patients. The findings of this study suggest that in addition to providing excellent vision, multifocal contact lenses provide functional vision performance equal to PAL spectacle wear and patients may prefer them over PAL spectacles.
Collapse
Affiliation(s)
| | | | - Nick Fogt
- The Ohio State University College of Optometry, United States
| |
Collapse
|
47
|
Haworth K, Travis D, Abariga SA, Fuller D, Pucker AD. Silicone hydrogel versus hydrogel soft contact lenses for differences in patient-reported eye comfort and safety. Hippokratia 2021. [DOI: 10.1002/14651858.cd014791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
| | - Darian Travis
- School of Optometry; University of Alabama at Birmingham; Birmingham Alabama USA
| | - Samuel A Abariga
- Department of Ophthalmology; University of Colorado Anschutz Medical Campus; Denver Colorado USA
| | - Daniel Fuller
- Cornea Contact Lens Service; The Eye Center, Southern College of Optometry; Memphis TN USA
| | - Andrew D Pucker
- School of Optometry; University of Alabama at Birmingham; Birmingham Alabama USA
| |
Collapse
|
48
|
Heynen M, Ng A, Martell E, Subbaraman LN, Jones L. Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems. Clin Ophthalmol 2021; 15:1727-1733. [PMID: 33935489 PMCID: PMC8079347 DOI: 10.2147/opth.s296116] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 03/17/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose The amount of protein deposition on soft contact lenses and to what extent the proteins are denatured may have an impact on comfortable wearing times of contact lenses. The purpose of this study was to evaluate the effects of two lens care systems on total protein and the quantity and activity of lysozyme deposited on worn senofilcon A, silicone hydrogel contact lenses. Participants and Methods Thirty symptomatic soft contact lens wearers were enrolled into a 4-week prospective, randomized, bilateral eye, daily-wear, crossover, double-masked study. Participants were fitted with biweekly senofilcon A lenses and were assigned either a polyquaternium-1 and myristamidopropyl dimethylamine-containing system (OPTI-FREE RepleniSH) or a peroxide-based system (CLEAR CARE). After each wear period, proteins were extracted from the lenses and analyzed for total protein, total lysozyme quantity and activity. Results The use of either the peroxide-based system or the polyquaternium-1 and myristamidopropyl dimethylamine-containing system resulted in no difference (P>0.05) to the amount of total protein deposited on the lenses (6.7 ± 2.8 micrograms/lens versus 7.3 ± 2.8 micrograms/lens, respectively) or to the amount of denatured lysozyme deposits (0.8 ± 0.7 versus 0.9 ± 0.7 micrograms/lens), respectively. The total amount of lysozyme deposited on the lenses was significantly lower when using the peroxide-based system (1.3 ± 0.9 micrograms/lens) compared to the polyquaternium-1 and myristamidopropyl dimethylamine-containing system (1.7 ± 1.0 micrograms/lens) (P=0.02). Conclusion The inactivation of lysozyme deposited on senofilcon A lenses when disinfected with the peroxide-based or the polyquaternium-1 and myristamidopropyl dimethylamine-containing systems were neither statistically nor clinically significant and the overall amounts of denatured lysozyme recovered from the lenses were low (<1 microgram/lens).
Collapse
Affiliation(s)
- Miriam Heynen
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Alan Ng
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Elizabeth Martell
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lyndon Jones
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada.,Centre for Eye and Vision Research (CEVR), Hong Kong Science Park, Hong Kong
| |
Collapse
|
49
|
Diec J, Naduvilath T, Tilia D, Bakaraju RC. The Relationship Between Vision and Comfort in Contact Lens Wear. Eye Contact Lens 2021; 47:271-276. [PMID: 33009260 DOI: 10.1097/icl.0000000000000743] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/26/2020] [Indexed: 12/12/2022]
Abstract
OBJECTIVE Understand relationship between vision and comfort in contact lens (CL) wear. METHODS Retrospective analysis of five trials using similar protocols with nonpresbyopic (NP) myopes or presbyopic participants (Px) wearing various simultaneous-image designs (SM) and single-vision (SV) CL (NP only). Questionnaires (vision satisfaction, vision clarity: distance/intermediate/near, comfort) on 1 to 10 scale were administered 1 week after fitting. Vision/comfort relationship was analyzed using linear mixed model and presented as regression coefficient with 95% confidence intervals (CIs). RESULTS Vision ratings correlated with comfort ratings, although this varied depending on type of vision rating and Px category. Vision satisfaction influenced comfort for the NP-SV group (slope: 0.8; 95% CI: 0.58-1.01, P≤0.001), but was significantly lower in the presbyopic group (slope: 0.38; 95% CI: 0.33-0.42; P≤0.001). Controlling for lens material obtained similar results. In the reverse relationship, comfort had a significant impact on vision satisfaction, although again at varying levels for each Px group. NP-SV demonstrated the weakest relationship (slope: 0.47; 95% CI: 0.35-0.59, P≤0.001) in comparison to NP-SM and P-SM groups. CONCLUSION Vision and comfort in CL wear are inter-related. Consideration of Px characteristics, visual stimulus, and CL comfort needs to be accounted for when assessing overall CL experience.
Collapse
Affiliation(s)
- Jennie Diec
- Brien Holden Vision Institute Limited (J.D., T.N., D.T., R.C.B.), Sydney, Australia ; and School of Optometry and Vision Sciences (T.N., D.T., R.C.B.), Sydney, Australia
| | | | | | | |
Collapse
|
50
|
Tichenor AA, Cofield SS, Gann D, Elder M, Ng A, Walsh K, Jones LW, Nichols JJ. Frequency of Contact Lens Complications Between Contact Lens Wearers Using Multipurpose Solutions Versus Hydrogen Peroxide in the United States and Canada. Eye Contact Lens 2021; 47:277-282. [PMID: 33290295 DOI: 10.1097/icl.0000000000000761] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/08/2020] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To retrospectively compare frequency of contact lens (CL) complications in soft CL users of hydrogen peroxide (H2O2) and multipurpose solutions (MPS). METHODS This was a multicenter, retrospective chart review of CL records from each patient's three most recent eye examinations at academic and private practices. Patients must have used the same solution type for at least 3 years. Univariate analyses were conducted using t tests, and chi-square or Fisher's exact test for categorical measures. RESULTS There were 1,137 patients included, with 670 (59%) using MPS and 467 (41%) H2O2. In total, 706 (62%) experienced at least one complication; 409 used MPS and 297 used H2O2. There was no difference in the proportion of patients experiencing at least one complication between MPS (61%) and H2O2 (64%) (P=0.38). Multipurpose solutions users were more likely to report discomfort compared with H2O2 users (P=0.04). Presumed microbial keratitis was experienced by 16 MPS and nine H2O2 users (P=0.60). CONCLUSIONS No significant differences were found in the frequency of CL complications between MPS and H2O2. H2O2 users were less likely to report discomfort and thus switching to a H2O2 system may be an alternative in CL users with discomfort.
Collapse
Affiliation(s)
- Anna A Tichenor
- Indiana University (A.A.T.), School of Optometry, Bloomington, IN; University of Alabama at Birmingham School of Optometry (S.S.C., J.J.N.), Birmingham, AL; EyeCare Associates (D.G.), Hueytown, Alabama; Centre for Ocular Research and Education (CORE) (M.E., A.N., K.W., L.W.J.), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada ; and Centre for Eye and Vision Research (LWJ), Hong Kong
| | | | | | | | | | | | | | | |
Collapse
|