1
|
Gallo Afflitto G, Chou TH, Swaminathan SS, Aiello F, Gedde SJ, Nucci C, Porciatti V. Pattern Electroretinogram in Ocular Hypertension, Glaucoma Suspect and Early Manifest Glaucoma Eyes: A Systematic Review and Meta-analysis. OPHTHALMOLOGY SCIENCE 2023; 3:100322. [PMID: 37334035 PMCID: PMC10272507 DOI: 10.1016/j.xops.2023.100322] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 04/06/2023] [Accepted: 04/24/2023] [Indexed: 06/20/2023]
Abstract
Topic To provide standardized confidence limits of the transient pattern electroretinogram (tPERG) P50 and N95 and steady state pattern electroretinogram (ssPERG) amplitudes in normal controls as compared to ocular hypertension (OHT), glaucoma suspect (GS), or early manifest glaucoma (EMG) eyes. Clinical Relevance The identification of standardized confidence limits in the context of pattern electroretinogram (PERG) might overcome the high intrinsic variability of the measure, and it might lead to a more intuitive understanding of the results as well as to an easier comparison of data from multiple tests, sites, and operators. Methods The study protocol was prospectively registered on the International Prospective Register of Systematic Reviews (ID: CRD42022370032). A literature search was conducted on PubMed, Web of Science, and Scopus. Studies comparing PERG raw data in normal control eyes as compared to OHT, GS, or EMG were included. The risk of bias was assessed using the National Institute for Health and Clinical Excellence quality assessment tool. The main outcome was the P50, N95, and ssPERG amplitude difference between the control and the study groups' eyes. The standardized mean difference was calculated as a measure of the effect size for the primary outcome. A subanalysis was conducted based on the type of electrodes adopted for the PERG measurements (invasive vs. noninvasive). Results Of the 4580 eligible papers, only 23 were included (1754 eyes). Statistically significant amplitude differences were found in the P50, N95, and ssPERG amplitudes between normal controls and OHT, GS, and EMG eyes. The highest standardized mean difference values were observed in the ssPERG amplitude in all 3 sets of comparison. The subanalysis did not reveal any statistically significant differences between invasive and noninvasive recording strategies. Conclusions The use of standardized values as the main outcome measures in the context of the PERG data analysis is a valid approach, normalizing several confounding factors which have affected the clinical utility of PERG both for individual patients and in clinical trials. Steady state PERG apparently better discriminates diseased eyes compared to tPERG. The adoption of skin-active electrodes is able to adequately discriminate between healthy and diseased statuses. Financial Disclosures Proprietary or commercial disclosure may be found after the references.
Collapse
Affiliation(s)
- Gabriele Gallo Afflitto
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida
- Ophthalmology Unit, Department of Experimental Medicine, University of Rome “Tor Vergata”, Rome, Italy
| | - Tsung-Han Chou
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida
| | - Swarup S. Swaminathan
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida
| | - Francesco Aiello
- Ophthalmology Unit, Department of Experimental Medicine, University of Rome “Tor Vergata”, Rome, Italy
| | - Steven J. Gedde
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida
| | - Carlo Nucci
- Ophthalmology Unit, Department of Experimental Medicine, University of Rome “Tor Vergata”, Rome, Italy
| | - Vittorio Porciatti
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida
| |
Collapse
|
2
|
Shin HJ, Oh SE, Park CK, Park HYL. Importance of Pattern Standard Deviation of Humphrey 10-2 Visual Field to Evaluate Central Visual Function in Patients with Early-Stage Glaucoma. J Clin Med 2023; 12:5091. [PMID: 37568492 PMCID: PMC10419394 DOI: 10.3390/jcm12155091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 07/31/2023] [Accepted: 08/01/2023] [Indexed: 08/13/2023] Open
Abstract
To explore various parameters that can evaluate the central visual impairment in patients with early-stage glaucoma, we included patients into a study with central visual impairments with an MD value greater than -6.0 dB on the 24-2 VF test. A possible association between structural parameters acquired by OCT and functional parameters of VF and PERG was determined. A total of 70 eyes of patients with suspected glaucoma or NTG underwent VF, OCT, and PERG examinations. The patients were classified into two groups according to the MD of the 24-2 VF test. We used Pearson correlation analysis to evaluate the relationships between GCIPL thickness/RNFL thickness and visual functional parameters, such as PERG and perimetry. Linear regression analyses were conducted to evaluate the significant factors affecting the PSD of VF 10-2. In the low MD group, the P50 amplitude presented significant correlations (r = 0.346, p = 0.048) with GCIPL thickness. In the correlation analysis of the high MD group, it was found that only the PSD of 10-2 uniquely presented borderline significant correlations with GCIPL thickness (r = -0.327, p = 0.055), and no other functional parameter showed significant correlation. Univariate and multivariate analyses revealed that GCIPL thickness was significantly associated with a PSD of 10-2 VF (p < 0.001 and 0.013, respectively). Among various parameters, the P50 amplitude and 10-2 PSD demonstrated statistically borderline significant structure-function relationships with GCIPL thickness in early-stage glaucoma.
Collapse
Affiliation(s)
| | | | | | - Hae-Young Lopilly Park
- Department of Ophthalmology, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea; (H.J.S.); (S.E.O.); (C.K.P.)
| |
Collapse
|
3
|
Sharif NA. Identifying new drugs and targets to treat rapidly elevated intraocular pressure for angle closure and secondary glaucomas to curb visual impairment and prevent blindness. Exp Eye Res 2023; 232:109444. [PMID: 36958427 DOI: 10.1016/j.exer.2023.109444] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 02/23/2023] [Accepted: 03/16/2023] [Indexed: 03/25/2023]
Abstract
A multitude of pharmacological compounds have been shown to lower and control intraocular pressure (IOP) in numerous species of animals and human subjects after topical ocular dosing or via other routes of administration. Most researchers have been interested in finding drug candidates that exhibit a relatively long duration of action from a chronic therapeutic use perspective, for example to treat ocular hypertension (OHT), primary open-angle glaucoma and even normotensive glaucoma. However, it is equally important to seek and characterize treatment modalities which offer a rapid onset of action to help provide fast relief from quickly rising IOP that occurs in certain eye diseases. These include acute angle-closure glaucoma, primary angle-closure glaucoma, uveitic and inflammatory glaucoma, medication-induced OHT, and other secondary glaucomas induced by eye injury or infection which can cause partial or complete loss of eyesight. Such fast-acting agents can delay or prevent the need for ocular surgery which is often used to lower the dangerously raised IOP. This research survey was therefore directed at identifying agents from the literature that demonstrated ocular hypotensive activity, normalizing and unifying the data, determining their onset of action and rank ordering them on the basis of rapidity of action starting within 30-60 min and lasting up to at least 3-4 h post topical ocular dosing in different animal species. This research revealed a few health authority-approved drugs and some investigational compounds that appear to meet the necessary criteria of fast onset of action coupled with significant efficacy to reduce elevated IOP (by ≥ 20%, preferably by >30%). However, translation of the novel animal-based findings to the human conditions remains to be demonstrated but represent viable targets, especially EP2-receptor agonists (e.g. omidenepag isopropyl; AL-6598; butaprost), mixed activity serotonin/dopamine receptor agonists (e.g. cabergoline), rho kinase inhibitors (e.g. AMA0076, Y39983), CACNA2D1-gene product inhibitors (e.g. pregabalin), melatonin receptor agonists, and certain K+-channel openers (e.g. nicorandil, pinacidil). Other drug candidates and targets were also identified and will be discussed.
Collapse
Affiliation(s)
- Najam A Sharif
- Institute of Ophthalmology, University College London (UCL), London, UK; Imperial College of Science and Technology, St. Mary's Campus, London, UK; Eye-ACP Duke-National University of Singapore Medical School, Singapore; Singapore Eye Research Institute (SERI), Singapore; Department of Pharmacy Sciences, Creighton University, Omaha, NE, USA; Department of Pharmacology and Neuroscience, University of North Texas Health Sciences Center, Fort Worth, Texas, USA; Department of Pharmaceutical Sciences, College of Pharmacy and Health Sciences, Texas Southern University, Houston, Texas, USA; Ophthalmology Innovation Center, Santen Inc USA, Emeryville, CA, USA.
| |
Collapse
|
4
|
Tirsi A, Shah PP, Gliagias V, Barmas-Alamdari D, Orshan D, Tsai J, Tello C. Posterior Pole Asymmetry Analysis as a Diagnostic Tool in Glaucoma Suspects: An Electrophysiological Approach. Clin Ophthalmol 2023; 17:1777-1787. [PMID: 37366515 PMCID: PMC10290849 DOI: 10.2147/opth.s411647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 06/09/2023] [Indexed: 06/28/2023] Open
Abstract
Purpose Spectral domain optical coherence tomography (SD-OCT) with posterior pole asymmetry analysis (PPAA) provides a mapping of posterior pole retinal thickness with asymmetry analysis between hemispheres of each eye. We investigated whether these structural abnormalities were correlated with functional retinal ganglion cell (RGC) loss, quantified by steady state pattern electroretinogram (ssPERG), in glaucoma suspects (GS). Methods Twenty GS (34 eyes) were enrolled in a prospective study at the Manhattan Eye, Ear, and Throat Hospital. All subjects underwent ophthalmological examination, including Humphrey visual field, Spectralis Glaucoma Module Premium Edition (GMPE) SD-OCT PPAA, and ssPERG testing. The ability of ssPERG parameters (Magnitude [Mag, µv], MagnitudeD [MagD, µv], and MagD/Mag ratio) to predict PPAA thickness (total, superior, and inferior thickness, [µm]) was tested via adjusted multivariate linear regression analysis. Results Mag explained 8% of variance in total PPAA change (F(1,29)=6.33, B=6.86, 95% CI: 1.29-12.44, p=0.018), 8% in superior PPAA change (F(1,29)=5.57, B=6.92, 95% CI: 0.92-12.92, p=0.025), and 7.1% in inferior PPAA change (F(1,29)=5.83, B=6.80, 95% CI: 1.04-12.56, p=0.022). Similarly, MagD explained 9.7% of variance in total PPAA change (F(1,29)=8.09, B=6.47, 95% CI: 1.82-11.13, p=0.008), 10% in superior PPAA change (F(1,29)=7.33, B=6.63, 95% CI: 1.62-11.63, p=0.011), and 8.5% in inferior PPAA change (F(1,29)=7.25, B=6.36, 95% CI: 1.53-11.18, p=0.012). MagD/Mag ratio and PPAA were not significantly associated. Conclusion To the best of our knowledge, this is the first study demonstrating a positive relationship between RGC dysfunction and retinal thickness changes between the superior and inferior hemispheres. The detection of asymmetrical structural loss, combined with functional RGC assessment using ssPERG, may be an informative tool for early glaucoma diagnosis.
Collapse
Affiliation(s)
- Andrew Tirsi
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, 11549, USA
- Department of Ophthalmology, Manhattan Eye, Ear, and Throat Hospital, New York City, NY, 10065, USA
| | - Paras P Shah
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, 11549, USA
| | - Vasiliki Gliagias
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, 11549, USA
| | - Daniel Barmas-Alamdari
- Department of Ophthalmology, Manhattan Eye, Ear, and Throat Hospital, New York City, NY, 10065, USA
| | - Derek Orshan
- Department of Ophthalmology, Manhattan Eye, Ear, and Throat Hospital, New York City, NY, 10065, USA
| | - Joby Tsai
- Department of Ophthalmology, Manhattan Eye, Ear, and Throat Hospital, New York City, NY, 10065, USA
| | - Celso Tello
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, 11549, USA
- Department of Ophthalmology, Manhattan Eye, Ear, and Throat Hospital, New York City, NY, 10065, USA
| |
Collapse
|
5
|
Predicting Visual Field Progression by Optical Coherence Tomography Angiography and Pattern Electroretinography in Glaucoma. J Glaucoma 2022; 31:881-890. [PMID: 35882039 DOI: 10.1097/ijg.0000000000002088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Accepted: 06/12/2022] [Indexed: 02/04/2023]
Abstract
PRCIS Reduced P50-N95 amplitude on pattern electroretinography (PERG) and the presence of microvasculature dropout (MvD) on optical coherence tomography angiography (OCT-A) at baseline were significant factors associated with visual field (VF) progression in predominantly normal tension glaucoma (NTG) patients. OBJECTIVE We investigated the baseline demographics and ocular characteristics that predict future progression in glaucoma patients, including PERG and OCT-A parameters. METHODS One Hundred forty eyes with open angle glaucoma that were prospectively enrolled and followed up for at least 3 years, and underwent at least 5 serial VF tests were included. Baseline PERG was performed, and N35, P50, and N95 latencies and amplitudes were obtained. Superficial vessel density at the macula and complete loss of microvasculature within the deep retinal layer of the parapapillary region (MvD) were evaluated from baseline OCT-A images. Eyes with a glaucomatous VF defect in either both hemifields within 24 points of a central 10 degrees of fixation, and with no VF abnormality in the nasal periphery outside 10 degrees of fixation, were considered to have isolated central scotoma. During follow-up, detected disc hemorrhage (DH) was recorded. Parameters associated with VF progression were determined using linear regression analysis of the mean deviation (MD) values, in combination with an event-based analysis using the Glaucoma Progression Analysis (GPA) software from the Humphrey Field Analyzer. "Likely progression" using GPA was considered to have glaucoma progression. RESULTS Of the 140 eyes, 107 (76.4%) were NTG and 57 (40.7%) exhibited glaucoma progression as defined by Humphrey VF GPA. The MD slopes were -0.43±1.11 dB/y in the progressors and 0.59±1.27 dB/y in the nonprogressors ( P <0.001). Glaucoma patients with progression showed frequent MvD on OCT-A, isolated central scotoma, frequent DH, and reduced baseline P50-N95 amplitude compared with patients without progression. Age at diagnosis ( P =0.038) and baseline P50-N95 amplitude ( P =0.019) showed significant associations with the MD slope. The presence of MvD on OCT-A ( P <0.001) and baseline P50-N95 amplitude ( P =0.037) were significantly associated with VF progression on GPA. CONCLUSIONS The presence of MvD and retinal ganglion cell dysfunction by PERG at baseline, DH or central scotoma were significant factors associated with VF progression in predominantly NTG patients. These patients should be monitored more closely.
Collapse
|
6
|
Sharif NA. Therapeutic Drugs and Devices for Tackling Ocular Hypertension and Glaucoma, and Need for Neuroprotection and Cytoprotective Therapies. Front Pharmacol 2021; 12:729249. [PMID: 34603044 PMCID: PMC8484316 DOI: 10.3389/fphar.2021.729249] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 08/18/2021] [Indexed: 12/11/2022] Open
Abstract
Damage to the optic nerve and the death of associated retinal ganglion cells (RGCs) by elevated intraocular pressure (IOP), also known as glaucoma, is responsible for visual impairment and blindness in millions of people worldwide. The ocular hypertension (OHT) and the deleterious mechanical forces it exerts at the back of the eye, at the level of the optic nerve head/optic disc and lamina cribosa, is the only modifiable risk factor associated with glaucoma that can be treated. The elevated IOP occurs due to the inability of accumulated aqueous humor (AQH) to egress from the anterior chamber of the eye due to occlusion of the major outflow pathway, the trabecular meshwork (TM) and Schlemm’s canal (SC). Several different classes of pharmaceutical agents, surgical techniques and implantable devices have been developed to lower and control IOP. First-line drugs to promote AQH outflow via the uveoscleral outflow pathway include FP-receptor prostaglandin (PG) agonists (e.g., latanoprost, travoprost and tafluprost) and a novel non-PG EP2-receptor agonist (omidenepag isopropyl, Eybelis®). TM/SC outflow enhancing drugs are also effective ocular hypotensive agents (e.g., rho kinase inhibitors like ripasudil and netarsudil; and latanoprostene bunod, a conjugate of a nitric oxide donor and latanoprost). One of the most effective anterior chamber AQH microshunt devices is the Preserflo® microshunt which can lower IOP down to 10–13 mmHg. Other IOP-lowering drugs and devices on the horizon will be also discussed. Additionally, since elevated IOP is only one of many risk factors for development of glaucomatous optic neuropathy, a treatise of the role of inflammatory neurodegeneration of the optic nerve and retinal ganglion cells and appropriate neuroprotective strategies to mitigate this disease will also be reviewed and discussed.
Collapse
Affiliation(s)
- Najam A Sharif
- Global Alliances and External Research, Ophthalmology Innovation Center, Santen Inc., Emeryville, CA, United States
| |
Collapse
|
7
|
Lee T, Seo DR, Kim JY, Choi W, Lee SY, Lee JM, Seong GJ, Kim CY, Bae HW. Relationship between N95 Amplitude of Pattern Electroretinogram and Optical Coherence Tomography Angiography in Open-Angle Glaucoma. J Clin Med 2020; 9:jcm9123854. [PMID: 33260929 PMCID: PMC7759986 DOI: 10.3390/jcm9123854] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 11/20/2020] [Accepted: 11/24/2020] [Indexed: 11/16/2022] Open
Abstract
Purpose: The pattern electroretinogram (PERG) is useful to detect retinal ganglion cell (RGC) damage in patients with glaucoma. Optical coherence tomography angiography (OCTA) measures retinal vessel density (VD), which is known to be reduced in glaucoma. There may be correlations between parameters of the PERG and OCTA in open-angle glaucoma (OAG). Methods: In total, 95 eyes of 95 OAG patients and 102 eyes of 102 normal controls were included in this study. N35, P50, and N95 latency along with P50 and N95 amplitude were obtained using the PERG. Retinal VD was measured around the peripapillary and macular area according to the ETDRS grid (concentric circles with diameters of 1, 3, and 6 mm), which is named a center (≤1 mm), an inner (1–3 mm), an outer (3–6 mm), and a full (≤6 mm) area. Pearson correlation analysis was done between parameters, and partial correlation analysis was done after adjusting confounding factors. Results: P50 amplitude, N95 amplitude, and VD of most measured areas were significantly lower in the OAG group compared to the normal group. N95 amplitude showed a statistically significant correlation with parameters of optical coherence tomography and visual field, peripapillary outer and full VD, and macular outer and full VD even after adjusting confounding factors. There was no significant correlation between parameters in the normal group. Conclusions: N95 amplitude was associated with structural and functional change including VD reduction in OAG. Microvascular alterations may be associated with dysfunctional changes of RGC recorded by the PERG in OAG.
Collapse
Affiliation(s)
- Taekjune Lee
- Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea; (T.L.); (D.R.S.); (J.Y.K.); (W.C.); (S.Y.L.); (G.J.S.); (C.Y.K.)
| | - Du Ri Seo
- Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea; (T.L.); (D.R.S.); (J.Y.K.); (W.C.); (S.Y.L.); (G.J.S.); (C.Y.K.)
| | - Joo Yeon Kim
- Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea; (T.L.); (D.R.S.); (J.Y.K.); (W.C.); (S.Y.L.); (G.J.S.); (C.Y.K.)
| | - Wungrak Choi
- Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea; (T.L.); (D.R.S.); (J.Y.K.); (W.C.); (S.Y.L.); (G.J.S.); (C.Y.K.)
| | - Sang Yeop Lee
- Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea; (T.L.); (D.R.S.); (J.Y.K.); (W.C.); (S.Y.L.); (G.J.S.); (C.Y.K.)
- Department of Ophthalmology, Yongin Severance Hospital, Yonsei University College of Medicine, 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si 16995, Korea
| | - Jun Mo Lee
- Siloam Eye Hospital, 181, Deungchon-ro, Gangseo-gu, Seoul 07668, Korea;
| | - Gong Je Seong
- Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea; (T.L.); (D.R.S.); (J.Y.K.); (W.C.); (S.Y.L.); (G.J.S.); (C.Y.K.)
| | - Chan Yun Kim
- Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea; (T.L.); (D.R.S.); (J.Y.K.); (W.C.); (S.Y.L.); (G.J.S.); (C.Y.K.)
| | - Hyoung Won Bae
- Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea; (T.L.); (D.R.S.); (J.Y.K.); (W.C.); (S.Y.L.); (G.J.S.); (C.Y.K.)
- Correspondence: ; Tel.: +82-2-2228-3570
| |
Collapse
|
8
|
Short-Term Steady-State Pattern Electroretinography Changes Using a Multi-Pressure Dial in Ocular Hypertensive, Glaucoma Suspect, and Mild Open-Angle Glaucoma Patients: A Randomized, Controlled, Prospective, Pilot Study. Ophthalmol Ther 2020; 9:981-992. [PMID: 32939747 PMCID: PMC7708609 DOI: 10.1007/s40123-020-00302-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 09/04/2020] [Indexed: 11/21/2022] Open
Abstract
Introduction This study evaluates the effects of the multi-pressure dial (MPD) on steady-state pattern electroretinography (ss-pERG) parameters. The study is a randomized, controlled, prospective, pilot trial in a private practice setting with ocular hypertensive (OHT), glaucoma suspect, and open-angle glaucoma (OAG) subjects. Methods This study included nine patients (64 ± 9.0 years, nine female) with OHT, glaucoma suspect, or mild OAG. One eye of each subject was randomized to receive negative periocular pressure, while the contralateral eye served as the intrasubject control through the goggle without negative pressure. The Diopsys High Contrast Sensitivity ss-pERG protocol was conducted on both eyes of each subject while wearing the MPD device. Application of negative periocular pressure was set at 50% of baseline intraocular pressure for each study eye. Results Following 2 h of negative periocular pressure application, the difference in MagnitudeD (MagD) from baseline for eyes randomized to receive negative periocular pressure (+ 0.17 versus − 0.26) was statistically significant (p = 0.023). Over the same period, the change in MagD/Magnitude (MagD/Mag ratio) from baseline for eyes randomized to receive negative periocular pressure was also higher (+ 0.14 versus − 0.16), compared to the control eyes, approached significance (p = 0.059). Conclusions Following 2 h of MPD wear, the measured MagD and MagD/Mag ratio improved compared to control, suggesting that negative periocular pressure application to the anterior globe can lead to short-term improvement in one measure of retinal ganglion cell function.
Collapse
|