1
|
Zhang S, Huang S, Tiemuerniyazi X, Song Y, Feng W. A Meta-Analysis of Early, Mid-term and Long-Term Mortality of On-Pump vs. Off-Pump in Redo Coronary Artery Bypass Surgery. Front Cardiovasc Med 2022; 9:869987. [PMID: 35548406 PMCID: PMC9081922 DOI: 10.3389/fcvm.2022.869987] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Accepted: 03/31/2022] [Indexed: 12/15/2022] Open
Abstract
We aimed to compare the early, mid-term, and long-term mortality between on-pump vs. off-pump redo coronary artery bypass grafting (CABG). We conducted a systematic search for studies comparing clinical outcomes of patients who underwent on-pump vs. off-pump redo CABG. We pooled the relevant studies quantitatively to compare the early (perioperative period, whether in hospital or within 30 days after discharge), mid-term (≥1 year and <5 years), and long-term (≥5 year) mortality of on-pump vs. off-pump redo CABG. A random-effect model was applied when there was high heterogeneity (I2 > 50%) between studies. Otherwise, a fixed-effect model was utilized. After systematic literature searching, 22 studies incorporating 5,197 individuals (3,215 in the on-pump group and 1,982 in the off-pump group) were identified. A pooled analysis demonstrated that compared with off-pump redo CABG, on-pump redo CABG was associated with higher early mortality (OR 2.11, 95%CI: 1.54-2.89, P < 0.00001). However, no significant difference was noted in mid-term mortality (OR 1.12, 95%CI: 0.57-2.22, P = 0.74) and long-term mortality (OR 1.12, 95%CI: 0.41-3.02, P = 0.83) between the two groups. In addition, the complete revascularization rate was higher in the on-pump group than the off-pump group (OR 2.61, 95%CI: 1.22-5.60, P = 0.01). In conclusion, the off-pump technique is a safe and efficient alternative to the on-pump technique, with early survival advantage and similar long-term mortality to the on-pump technique in the setting of redo CABG, especially in high-risk patients. Systematic Review Registration https://www.crd.york.ac.uk/PROSPERO/, identifier: CRD42021244721.
Collapse
Affiliation(s)
| | | | | | | | - Wei Feng
- Department of Cardiac Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
2
|
Tzoumas A, Giannopoulos S, Kakargias F, Kokkinidis DG, Giannakoulas G, Faillace RT, Bakoyiannis C, Doulamis IP, Avgerinos DV. Repeat Coronary Artery Bypass Grafting: A Meta-Analysis of Off-Pump versus On-Pump Techniques in a Large Cohort of Patients. Heart Lung Circ 2021; 30:1281-1291. [PMID: 33810970 DOI: 10.1016/j.hlc.2021.02.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 02/03/2021] [Accepted: 02/08/2021] [Indexed: 12/17/2022]
Abstract
BACKGROUND Redo coronary artery bypass grafting (CABG) can be performed with either the off-pump (OPCAB) or the on-pump (ONCAB) technique. METHOD Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), this meta-analysis compared the safety and efficacy of OPCAB versus ONCAB redo CABG. RESULTS Twenty-three (23) eligible studies were included (OPCAB, n=2,085; ONCAB, n=3,245). Off-pump CABG significantly reduced the risk of perioperative death (defined as in-hospital or 30-day death rate), myocardial infarction, atrial fibrillation, and acute kidney injury. The two treatment approaches were comparable regarding 30-day stroke and late all-cause mortality. CONCLUSIONS Off-pump redo CABG resulted in lower perioperative death and periprocedural complication rates. No difference was observed in perioperative stroke rates and long-term survival between the two techniques.
Collapse
Affiliation(s)
| | - Stefanos Giannopoulos
- Division of Cardiology, Rocky Mountain Regional VA Medical Center, University of Colorado, Denver, CO, USA
| | | | - Damianos G Kokkinidis
- Department of Medicine, Jacobi Medical Center, Albert Einstein College of Medicine, Bronx, NY, USA
| | - George Giannakoulas
- Department of Cardiology, Aristotle University of Thessaloniki, AHEPA Hospital, Thessaloniki, Greece
| | - Robert T Faillace
- Department of Medicine, Jacobi Medical Center, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Christos Bakoyiannis
- First Department of Surgery, National and Kapodistrian University of Athens, Laikon General Hospital, Athens, Greece
| | - Ilias P Doulamis
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA.
| | - Dimitrios V Avgerinos
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York Presbyterian, New York, NY, USA
| |
Collapse
|
3
|
Zhang P, Wang L, Zhai K, Huang J, Wang W, Ma Q, Liu D, Gao B, Li Y. Off-pump versus on-pump redo coronary artery bypass grafting: a systematic review and meta-analysis. Perfusion 2020; 36:724-736. [PMID: 33016239 DOI: 10.1177/0267659120960310] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Background: Redo coronary artery bypass grafting (redo CABG) is associated with increased mortality and morbidity. The aim of this study was to systematically evaluate the evidence comparing the outcomes of off-pump with on-pump redo CABG. Methods: Studies were systematically searched and identified using PubMed, EMBASE, the Cochrane Library, and the International Clinical Trials Registry Platform (ICTRP) by two researchers independently. The primary outcome was 30-day mortality, and the secondary outcomes were in-hospital mortality, post-operative complications, completeness of revascularization, blood transfusion rate, duration of mechanical ventilation, intensive care unit and hospital stays. Results: The 21 studies including 4,889 patients were enrolled in our meta-analysis. Compared with on-pump, the off-pump technique was associated with significantly reduced 30-day mortality (odds ratio [OR] = 0.43, 95% confidence interval [CI] = 0.26-0.72, p = 0.001). Moreover, a notably decreased in-hospital mortality (OR = 0.55, 95% CI = 0.39-0.76, p = 0.0004) and incidence of post-operative new-onset atrial fibrillation, myocardial infarction, acute kidney injury, low cardiac output state, blood transfusion rate (OR = 0.46, 95% CI = 0.35-0.60, p < 0.00001; OR = 0.54, 95% CI = 0.38-0.78, p = 0.0007; OR = 0.51, 95% CI = 0.37-0.70, p < 0.0001; OR = 0.31, 95% CI = 0.20-0.47, p < 0.00001; OR = 0.29, 95% CI = 0.14-0.61, p = 0.001) and significantly shortened duration of mechanical ventilation, intensive care unit and hospital stays (mean difference [MD] = −8.21 h, 95% CI = −11.74 to −4.68, p < 0.00001; MD = −0.77 d, 95% CI = −0.81 to −0.73, p < 0.00001; MD = −2.24 d, 95% CI = −3.17 to −1.32, p < 0.00001) could be observed when comparing the outcomes of off-pump with on-pump redo CABG. There was nonsignificant difference between off-pump and on-pump redo CABG in completeness of revascularization. Conclusion: In patients undergoing redo CABG surgery, the off-pump technique was associated with decreased mortality, less post-operative complications when compared to on-pump.
Collapse
Affiliation(s)
- Pengbin Zhang
- Department of Cardiac Surgery, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
- Laboratory of Extracorporeal Life Support, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
| | - Liping Wang
- Department of Cardiac Surgery, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
| | - Kerong Zhai
- Department of Cardiac Surgery, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
- Laboratory of Extracorporeal Life Support, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
| | - Jian Huang
- Department of Cardiac Surgery, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
- Laboratory of Extracorporeal Life Support, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
| | - Weifan Wang
- Department of Cardiac Surgery, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
| | - Qi Ma
- Department of Cardiac Surgery, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
| | - Debin Liu
- Department of Cardiac Surgery, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
| | - Bingren Gao
- Department of Cardiac Surgery, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
| | - Yongnan Li
- Department of Cardiac Surgery, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
- Laboratory of Extracorporeal Life Support, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
| |
Collapse
|