1
|
León-Ibáñez L, Piñero DP. Analysis of the visual function with the continuous transitional focus intraocular lens Precizon Presbyopic. Eur J Ophthalmol 2024:11206721241293830. [PMID: 39491884 DOI: 10.1177/11206721241293830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2024]
Abstract
PURPOSE To evaluate the clinical outcomes of a refractive multi-segmented continuous transitional focus intraocular lens (IOL), analyzing the potential influence of patient pupil dynamics on these outcomes. METHODS Retrospective consecutive case series study enrolling 40 eyes (20 patients, 47-81 years) implanted with the Precizon Presbyopic IOL (Ophtec BV). The following clinical outcomes were analyzed during a mean follow-up of 12.1 months (2-24 months): visual acuity, refraction, contrast sensitivity (CS) under photopic and mesopic conditions, binocular defocus curve and evaluation of the perception of disturbing visual symptoms with a validated questionnaire. RESULTS Mean binocular uncorrected distance (UDVA), distance-corrected intermediate (DCIVA), uncorrected near (UNVA) and distance-corrected near visual acuities (DCNVA) were -0.09 ± 0.07, 0.04 ± 0.05, 0.17 ± 0.12, and 0.15 ± 0.10 logMAR, respectively. In the binocular defocus curve, mean distance-corrected visual acuity was over 0.20 logMAR for defocus levels from +1.50 to -3.00 D. No significant correlations of photopic pupil diameter with postoperative visual data were found (-0.165 ≤ r ≤ 0.192, p ≥ 0.235). Moderate correlations of mesopic pupil size were found with visual acuities for the defocus levels of -2.50 (r = 0.454, p = 0.003), -3.00 (r = 0.609, p < 0.001), -3.50 (r = 0.519, p < 0.001), and -4.00 D (r = 0.403, p = 0.010). Only significant differences were found between mesopic and photopic CS for 12 cycles/degree (p = 0.010). No cases of severe glare or halos were detected. In contrast, 10% of patients referred the severe perception of starbursts postoperatively. Full spectacle independence was referred by almost all patients (90%). CONCLUSIONS The IOL demonstrates effective visual restoration at various distances, characterized by high levels of visual quality and minimal dependence on pupil dynamics.
Collapse
Affiliation(s)
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| |
Collapse
|
2
|
Alió JL, Martínez-Abad A, Ruiz-Mesa R, Kim HM, Mendicute J, Ribeiro FJ, Holzer MP, Cantó-Cerdán M. Visual and patient reported outcomes provided by a refractive multifocal intraocular lens based on continuous transitional focus. EYE AND VISION (LONDON, ENGLAND) 2024; 11:41. [PMID: 39402644 PMCID: PMC11479541 DOI: 10.1186/s40662-024-00408-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Accepted: 09/07/2024] [Indexed: 10/19/2024]
Abstract
PURPOSE To analyze the quality of vision of patients implanted bilaterally with the multifocal Precizon Presbyopic intraocular lens (IOL), as well as to evaluate the visual performance provided by the lens. SETTING Vissum Miranza Alicante. DESIGN Prospective multicenter study. METHODS 56 patients (mean age 65.0 ± 8.7 years old) underwent bilateral implantation with multifocal Precizon Presbyopic IOL. The quality of vision was assessed by a quality of vision questionnaire at 6 months after the implantation procedure, a complete eye examination was also performed including visual and refractive measurements, defocus curve and contrast sensitivity assessment. Visual and refractive variables were compared in preoperative, 3-month postoperative and 6-month postoperative visits by Wilcoxon test. RESULTS The quality of vision analysis showed the absence of severe glare and severe haloes in all evaluated patients. Likewise, non-symptoms of glare, haloes and starbursts were seen in 75%, 68%, and 55% of subjects, respectively. Efficacy and safety index was 1.26 and 1.42, respectively. The 6-month postoperative binocular uncorrected distance visual acuity and near uncorrected visual acuity were 0.00 ± 0.09 and 0.20 ± 0.13 logMAR, respectively. Mean spherical equivalent was 0.29 ± 0.45 D. CONCLUSIONS The Precizon Presbyopic NVA IOL (OPHTEC BV) provides a suitable quality of vision with a low rate of disturbance photic phenomena induction, as well as an excellent visual performance at main distances of sight accomplishing the visual demands of the majority of patients.
Collapse
Affiliation(s)
- Jorge L Alió
- Vissum Miranza, Avda de Denia s/n Edificio Vissum, 03016, Alicante, Spain.
- Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain.
- , Avda de Denia s/n Edificio Vissum, Alicante, 03016, Spain.
| | | | | | - Hyo Myung Kim
- Department of Ophthalmology, Korea University Anam Hospital, Seoul, Republic of Korea
| | - Javier Mendicute
- Department of Ophthalmology, Hospital Universitario Donostia, San Sebastián, Spain
| | - Filomena J Ribeiro
- Departamento de Oftalmologia do Hospital da Luz Lisboa, Universidade de Lisboa, Lisboa, Portugal
| | - Mike P Holzer
- Department of Ophthalmology, International Vision Correction Research Centre (IVCRC), University of Heidelberg, Heidelberg, Germany
| | - Mario Cantó-Cerdán
- Vissum Miranza, Avda de Denia s/n Edificio Vissum, 03016, Alicante, Spain
| |
Collapse
|
3
|
Salvá L, García S, García-Delpech S, Martínez-Espert A, Montagud-Martínez D, Ferrando V. Comparison of the Polychromatic Image Quality of Two Refractive-Segmented and Two Diffractive Multifocal Intraocular Lenses. J Clin Med 2023; 12:4678. [PMID: 37510792 PMCID: PMC10380361 DOI: 10.3390/jcm12144678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 07/11/2023] [Accepted: 07/12/2023] [Indexed: 07/30/2023] Open
Abstract
Evaluating chromatic aberration for a multifocal intraocular lens (MIOL) in vitro is essential for studying its performance because it helps determine the most appropriate lens for each patient, enhancing surgical outcomes. While refractive MIOLs with angular power variation have shown positive clinical outcomes, studies of these MIOLs on optical benches primarily employed monochromatic green light, neglecting the impact of longitudinal chromatic aberration (LCA) on MIOL performance. To address this gap, we evaluated the through-focus modulation transfer function (TF-MTF) and the point spread function (PSF) of two refractive segmented extended depth of focus intraocular lenses (IOLs) (Femtis Comfort and Precizon Presbyopic), comparing the results with those obtained with two widely known diffractive multifocal intraocular lenses (AcrySof IQ ReSTOR and FineVision Pod F). Measurements of the TF-MTF were conducted using both monochromatic and polychromatic light in a customized optical bench. The refractive designs exhibited distinct haloes in the PSFs. When comparing the refractive and diffractive designs, opposite signs of LCA were observed at near foci. These findings emphasize the influence of the optical design of IOLs on their performance under polychromatic light, providing valuable information for vision care professionals when selecting the most suitable lens for each patient.
Collapse
Affiliation(s)
- Luis Salvá
- Oftalmedic Salvà, 07013 Palma de Mallorca, Spain
| | - Scott García
- Oftalmedic Salvà, 07013 Palma de Mallorca, Spain
| | | | - Anabel Martínez-Espert
- Departamento de Óptica, Optometría y CC de la Visión, Universitat de València, 46100 Valencia, Spain
| | - Diego Montagud-Martínez
- Departamento de Óptica, Optometría y CC de la Visión, Universitat de València, 46100 Valencia, Spain
- Centro de Tecnologías Físicas, Universitat Politècnica de València, 46022 Valencia, Spain
| | - Vicente Ferrando
- Centro de Tecnologías Físicas, Universitat Politècnica de València, 46022 Valencia, Spain
| |
Collapse
|
4
|
Álvarez-García MT, Fuente-García C, Muñoz-Puyol C, Piñero DP. Clinical Outcomes with Extended Depth of Focus Intraocular Lenses in Cases in Which Multifocal Lenses Are Not Primarily Recommended. J Ophthalmol 2023; 2023:8814627. [PMID: 37362313 PMCID: PMC10289873 DOI: 10.1155/2023/8814627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 06/01/2023] [Accepted: 06/08/2023] [Indexed: 06/28/2023] Open
Abstract
Purpose The purpose of the study is to evaluate the visual and patient-reported outcomes of patients undergoing cataract surgery with implantation of an extended depth of focus (EDOF) intraocular lens (IOL) who were not primarily good candidates for multifocal IOL implantation. Methods Retrospective analysis of data from 30 eyes (23 patients) undergoing cataract surgery with implantation of one of two EDOF IOLs (follow-up: 37.9 ± 16.2 months) and prospective observational study including 106 eyes (78 patients) implanted with one of 6 different EDOF models (follow-up: 8.0 ± 7.7 months). Patients recruited had one of the following conditions: monofocal IOL implanted in the fellow eye, previous corneal refractive surgery, mild and nonprogressive maculopathy or glaucoma, age > 75 years, amblyopia, or previous vitrectomy. Results In the retrospective phase, significant improvements were found in uncorrected distance (UDVA), corrected distance (CDVA), and corrected near visual acuity (CNVA) (p ≤ 0.013), with a nonsignificant trend to improvement in uncorrected near visual acuity (UNVA). A total of 90% of patients were completely to moderately satisfied with the outcome achieved. In the prospective phase, significant improvements were found in UDVA, CDVA, UNVA, and CNVA (p ≤ 0.032), with a total of 85.5% of patients being completely to moderately satisfied (dissatisfaction 3.3%). In both phases, extreme difficulties were only reported by a limited percentage of patients for performing some near vision activities. Conclusions EDOF IOLs seem to be a viable option for providing an efficient visual rehabilitation with good levels of patient satisfaction and spectacle independence associated in patients that are not primarily good candidates for multifocal IOL implantation.
Collapse
Affiliation(s)
| | | | | | - David P. Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| |
Collapse
|
5
|
D’Oria F, Scotti G, Sborgia A, Boscia F, Alessio G. How Reliable Is Pyramidal Wavefront-Based Sensor Aberrometry in Measuring the In Vivo Optical Behaviour of Multifocal IOLs? SENSORS (BASEL, SWITZERLAND) 2023; 23:3534. [PMID: 37050594 PMCID: PMC10099035 DOI: 10.3390/s23073534] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 03/26/2023] [Accepted: 03/27/2023] [Indexed: 06/19/2023]
Abstract
Cataract or refractive lens surgery, along with the implantation of multifocal intraocular lenses (MF-IOL), enables a complete range of functional far, near and intermediate vision. Refractive, diffractive and extended depth of focus (EDoF) or combination of these principles represent the technology used to obtain this multifocality. Aberrometry makes it possible to study the aberrations induced by MF-IOLs. Among the different optical principles available to measure ocular aberrations, pyramidal wavefront-based sensor (PWS) aberrometry shows the highest resolution with MF-IOLs. Retinal image quality measured by a PWS aberrometer differed significantly according to the technology of the implanted lens. Monofocal and diffractive lenses showed the highest values of far-distance retinal image quality, followed by refractive and EDoF lenses; however, retinal image quality analysed in diffractive lenses appears to be more dependent on residual refractive error. Considering this limitation, PWS-aberrometry could be used to compare diffractive lenses. Nevertheless, further studies are needed to provide additional information about the clinical retinal image quality of MF-IOLs and to help surgeons in the important preoperative selection of IOLs.
Collapse
|
6
|
Yan W, Auffarth GU, Khoramnia R, Łabuz G. Spectral Effects and Range of Focus in a Multizonal-Refractive Intraocular Lens Compared with a Standard Trifocal Diffractive Design. Ophthalmol Ther 2023; 12:1621-1634. [PMID: 36890349 PMCID: PMC10164215 DOI: 10.1007/s40123-023-00679-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 02/06/2023] [Indexed: 03/10/2023] Open
Abstract
INTRODUCTION This study was performed to compare the optical performance of a multizonal presbyopia-correcting intraocular lens (IOL) and a conventional trifocal model. METHODS The optical quality and simulated visual acuity (VA) of 570 Precizon Presbyopic NVA (OPHTEC BV) and AcrySof IQ PanOptix (Alcon) were compared. The Precizon features a refractive design consisting of alternating optical zones that converge the incident light into two principal foci and a transitional zone for intermediate vision. By contrast, the PanOptix applies a diffractive (non-apodized) profile to achieve trifocality. Simulated VA was derived from the modulation transfer function. Chromatic aberration effects were also studied. RESULTS The diffractive and multizonal-refractive lenses yielded comparable simulated VAs at far focus (0.00 logMAR). All curves showed a reduction in expected VA with an increase in negative defocus. At - 1.0 D, the multizonal-refractive IOL's VA dropped by 0.05 logMAR, but for the diffractive model, it was one line (0.11 logMAR). The multizonal-refractive lens's VA prediction at the secondary peak was 0.03 logMAR-minimally better than the 0.06 logMAR of the diffractive lens at - 2.5 D. The refractive lens exhibited a 24% decrease in polychromatic optical quality due to material dispersion. The performance of PanOptix was more substantially affected, showing a 44% loss at 50 lp/mm at far, with minimal effects at other distances. CONCLUSION The multizonal-refractive lens does not fall short of the established trifocal IOL, and it can be used to extend the visual range of pseudophakic patients. Although the multizonal-refractive lens has lower material dispersion, the diffractive model corrects chromatism beyond far focus.
Collapse
Affiliation(s)
- Weijia Yan
- Department of Ophthalmology, The David J. Apple Center for Vision Research, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Gerd U Auffarth
- Department of Ophthalmology, The David J. Apple Center for Vision Research, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Ramin Khoramnia
- Department of Ophthalmology, The David J. Apple Center for Vision Research, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Grzegorz Łabuz
- Department of Ophthalmology, The David J. Apple Center for Vision Research, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| |
Collapse
|
7
|
Ribeiro F, Ferreira TB, Silva D, Matos AC, Gaspar S, Piñero DP. Analysis of Daily Visual Habits in a Presbyopic Population. J Ophthalmol 2023; 2023:6440954. [PMID: 37089413 PMCID: PMC10118895 DOI: 10.1155/2023/6440954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Revised: 03/20/2023] [Accepted: 03/27/2023] [Indexed: 04/25/2023] Open
Abstract
Purpose To evaluate and report the visual habits and requirements of a sample of presbyopic patients using an advanced sensor. Methods Transversal study collecting clinical data from 40 presbyopes candidates for presbyopia-correction intraocular lens (IOL) implantation with mean age of 61.0 years (43-80 years). A complete ophthalmological examination was performed in all patients including visual, refractive, an ocular biometric analysis. Furthermore, patients were instructed about the use of the Vivior Monitor system (Vivior AG, Zürich, Switzerland), which consists of a series of sensors attached to the rim of the patient's glasses that capture information about the visual behavior of the patient. This device was worn for a period of 36 hours or more. The data collected were transferred to a database and analyzed. Results Mean percentages of time dedicated to distance, intermediate, and near vision were 27.25 ± 11.93% (5-65%), 30.23 ± 9.36% (12-50%), and 42.53 ± 14.96% (13-78%), respectively. Mean percentages of time performing activities under photopic, mesopic, and scotopic conditions were 37.08 ± 23.20% (5-87%), 33.65 ± 13.84% (6-67%), and 29.28 ± 17.03% (4-65%). The percentage of time with digital screens ranged from 2% to 48%. Age was significantly correlated with the percentage of time dedicated to distance vision (r = 0.317, p=0.047) and to activities performed under photopic conditions (r = -0.344, p=0.030). Conclusions Distance and illumination conditions used to perform different daily life visual activities vary significantly among presbyopes, with a trend to the dedication of more time to intermediate and near visual activities performed under photopic and mesopic conditions. Data interpretation should be done with care until a proper validation of the device used.
Collapse
Affiliation(s)
- Filomena Ribeiro
- Hospital da Luz Lisboa, Lisbon, Portugal
- Lisbon University, Lisbon, Portugal
- Visual Sciences Research Centre, Lisbon, Portugal
| | | | | | | | | | - David P. Piñero
- Department of Optics Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| |
Collapse
|
8
|
Alio JL, D'Oria F, Toto F, Balgos J, Palazon A, Versaci F, Del Barrio JLA. Retinal image quality with multifocal, EDoF, and accommodative intraocular lenses as studied by pyramidal aberrometry. EYE AND VISION 2021; 8:37. [PMID: 34615549 PMCID: PMC8496005 DOI: 10.1186/s40662-021-00258-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Accepted: 09/06/2021] [Indexed: 11/10/2022]
Abstract
Background To study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function (PSF) Strehl ratio using a pyramidal wavefront sensor (PWS)-based aberrometer. Methods This study included 194 eyes implanted with: (a) 19 AcrySof SA60AT (control group); (b) 19 Miniwell; (c) 24 LENTIS Mplus LS-313 MF30; d) 33 LENTIS Mplus LS-313 MF15; (e) 17 AkkoLens Lumina; (f) 31 AT LISA Tri 839MP; (g) 20 Precizon Presbyopic; (h) 20 AcrySof IQ PanOptix; (i) 11 Tecnis Eyhance. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root mean square (RMS), low-order aberration (LOA) and high-order aberration (HOA) RMS measured by PWS aberrometer. Results AT LISA Tri had the highest PSFw2 Strehl ratio at both 3.0- and 4.0-mm pupil size (0.52 ± 0.14 and 0.31 ± 0.10; P < 0.05), followed by SA60AT (0.41 ± 0.11 and 0.28 ± 0.07) and PanOptix (0.4 ± 0.07 and 0.26 ± 0.04). AT LISA Tri was found to provide a significantly better retinal image quality than PanOptix at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.004). Mplus MF15 was found to be significantly better than Mplus MF30 at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.002). Total RMS, LOA RMS, HOA RMS, PSF Strehl ratio and PSFw2 varied significantly between the studied groups (P < 0.001). Conclusions Far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens. AT LISA Tri, SA60AT and PanOptix showed the highest values of far distance retinal image quality, while the lowest PSFw2 Strehl ratios were displayed by Miniwell, Mplus MF30 and Precizon Presbyopic.
Collapse
Affiliation(s)
- Jorge L Alio
- Vissum Innovation, Alicante, Spain. .,Division of Ophthalmology, Universidad Miguel Hernández, Vissum Miranza, c/ Cabañal, 1, 03016, Alicante, Spain.
| | - Francesco D'Oria
- Vissum Innovation, Alicante, Spain.,Division of Ophthalmology, Universidad Miguel Hernández, Vissum Miranza, c/ Cabañal, 1, 03016, Alicante, Spain.,Section of Ophthalmology, Department of Basic Medical Science, Neuroscience and Sense Organs, University of Bari, Bari, Italy
| | | | | | - Antonio Palazon
- Department of Clinical Medicine, Miguel Hernández University, San Juan de Alicante, Spain
| | - Francesco Versaci
- R&D Department, Costruzione Strumenti Oftalmici (CSO), Florence, Italy
| | - Jorge L Alio Del Barrio
- Vissum Innovation, Alicante, Spain.,Division of Ophthalmology, Universidad Miguel Hernández, Vissum Miranza, c/ Cabañal, 1, 03016, Alicante, Spain
| |
Collapse
|
9
|
COMPARISON OF REFRACTIVE AND VISUAL OUTCOMES OF THREE PRESBYOPIA-CORRECTING INTRAOCULAR LENSES. J Cataract Refract Surg 2021; 48:280-287. [PMID: 34321410 DOI: 10.1097/j.jcrs.0000000000000743] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Accepted: 06/28/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate and compare the clinical outcomes after cataract surgery with implantation of three different types of trifocal diffractive intraocular lenses (IOLs). SETTING Hospital da Luz, Lisbon, Portugal. DESIGN Prospective comparative case series. METHODS 180 eyes of 90 patients undergoing phacoemulsification cataract surgery with implantation of one of these trifocal IOLs were enrolled: Tecnis Synergy (J&J Vision) (Synergy group, 30 patients), Acrysof PanOptix (Alcon) (PanOptix group, 30 patients), and POD F (PhysIOL) (Finevision group, 30 patients). The outcomes in terms of distance, intermediate and near visual acuity (VA), refraction, defocus curve, photic phenomena and spectacle independence were evaluated at 3-months follow-up. RESULTS No significant differences were found between groups in monocular distance-corrected intermediate (Synergy 0.04±0.11, PanOptix 0.05±0.09, Finevision 0.08±0.10; p=0.107) and near VA (0.01±0.08, 0.01±0.06, 0.04±0.10; p=0.186). Likewise, no significant differences among groups were found in binocular uncorrected distance (p=0.572), near (p=0.929) and intermediate VA (p=0.327). In contrast, significant differences between groups were found in the visual acuity for the vergence demands of -0.50, -1.00, -2.00, -3.50 and -4.00 D (p≤0.045). No significant differences among groups were found either in the frequency, severity and bothersomeness of different disturbing visual symptoms, including glare and haloes (p≥0.129). More than 96% of patients in all groups did not require the use of spectacles at any distance after surgery. CONCLUSIONS The three trifocal IOLs evaluated provide an effective visual rehabilitation with minimal incidence of photic phenomena. A trend to obtain a wider range of functional focus was observed with the Tecnis Synergy IOL.
Collapse
|
10
|
Gabrić N, Gabrić I, Gabrić K, Biščević A, Piñero DP, Bohač M. Clinical Outcomes With a New Continuous Range of Vision Presbyopia-Correcting Intraocular Lens. J Refract Surg 2021; 37:256-262. [PMID: 34038663 DOI: 10.3928/1081597x-20210209-01] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
PURPOSE To evaluate the clinical outcomes including patient-reported outcome measures in a sample of eyes undergoing bilateral cataract surgery with implantation of a new model of presbyopia-correcting intraocular lens (IOL). METHODS This non-randomized prospective case series enrolled 206 eyes of 103 patients undergoing phacoemulsification cataract surgery with bilateral implantation of the TECNIS Synergy IOL (Johnson & Johnson Vision). High and low contrast visual acuity, refractive, defocus curve, and patient-reported visual performance (Catquest-9SF questionnaire) outcomes were evaluated during a 3-month follow-up. RESULTS A total of 96.1% (99 of 103) and 91.3% (94 of 103) of patients achieved binocular postoperative uncorrected distance (UDVA) and near visual acuity (UNVA) of 0.00 logMAR (20/20), respectively. Mean postoperative mesopic UNVA for both eyes was 0.14 ± 0.03 logMAR. Likewise, mean binocular UDVA and UNVA were 0.00 ± 0.03 and 0.04 ± 0.02 logMAR. An almost flat mean defocus curve was obtained, with visual acuities between 0.00 and 0.10 logMAR for most defocus levels in both eyes. A reduction of contrast led to a limited but statistically significant change in UNVA in both eyes (P < .001). The Rasch calibrated scoring of item 2 and the Rasch calibrated mean score of the Catquest-9SF questionnaire increased significantly with surgery (P < .001). CONCLUSIONS This new presbyopia-correcting IOL provides a continuous range of functional focus, with a limited deterioration under mesopic conditions, which is perceived as a satisfactory outcome by the patient if proper patient selection is performed. [J Refract Surg. 2021;37(4):256-262.].
Collapse
|
11
|
Bilbao-Calabuig R, Gónzalez-López F, Llovet-Rausell A, Ortega-Usobiaga J, Tejerina Fernández V, Llovet-Osuna F. Lens-based surgical correction of presbyopia. Where are we in 2020? ACTA ACUST UNITED AC 2020; 96:74-88. [PMID: 32868085 DOI: 10.1016/j.oftal.2020.07.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 07/19/2020] [Accepted: 07/20/2020] [Indexed: 01/06/2023]
Abstract
INTRODUCTION Presbyopia is the progressive and irreversible loss of accommodation due to aging. It is one of the main causes of loss of quality of life in people from 45 years of age, due to the, often novel, dependence on spectacles. The eagerness to correct it by ophthalmologists impulsed by the desire of millions of people who suffer from it, has become one of the main drivers for the development of intraocular lens (IOL) technology over the last twenty years. MATERIAL AND METHODS This review briefly presents the different alternatives that have allowed us to improve the crystalline lens surgical approach of presbyopia; from monofocal lenses and monovision technique, accommodative, refractive, and diffractive multifocal lenses, and finally the most recent extended depth of focus/field lenses known as EDOFs. RESULTS Each IOL has its advantages, limitations and disadvantages. Furthermore, there is no single lens that suits the needs of all patients. CONCLUSIONS It is necessary to know the variety of lenses available, and to have an in-depth understanding of their optical properties, as well as the impact that these will have later on their clinical performance and on the visual quality of the patients. This should help us to select the best alternative for each of them.
Collapse
Affiliation(s)
- R Bilbao-Calabuig
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Madrid, España.
| | - F Gónzalez-López
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Madrid, España
| | - A Llovet-Rausell
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Valencia, España; Servicio Oftalmología, Hospital Universitario La Fe, Valencia, España
| | - J Ortega-Usobiaga
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Bilbao, España
| | - V Tejerina Fernández
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Madrid, España
| | - F Llovet-Osuna
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Madrid, España; Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Valencia, España
| |
Collapse
|
12
|
Alió JL, Yébana P, Cantó M, Plaza AB, Vega A, Alió Del Barrio JL, Lugo F. Clinical outcomes with a new design in multifocal intraocular lens: a pilot study. EYE AND VISION 2020; 7:38. [PMID: 32695838 PMCID: PMC7368690 DOI: 10.1186/s40662-020-00205-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 06/27/2020] [Indexed: 01/19/2023]
Abstract
Purpose To evaluate the clinical and visual outcomes, quality of near vision and the influence of photic phenomena in patients bilaterally implanted with a new Precizon Presbyopic multifocal intraocular lens (IOL). Methods In this prospective consecutive case series, 20 eyes of 10 patients were included (mean age 63.80 ± 12.55 years). Uncorrected and corrected visual acuity (far, intermediate and near), subjective refraction, binocular defocus curve, contrast sensitivity (CSV-1000) and quality of vision and satisfaction questionnaires were measured. The follow-up was 12 months after surgery. Results At 12 months after surgery, uncorrected distance visual acuity (UDVA) improved with surgery (p = 0.001) with a value of 0.08 ± 0.08 logMAR. Uncorrected near visual acuity (UNVA) was 0.22 ± 0.12 logMAR and distance corrected near visual acuity (DCNVA) was 0.16 ± 0.13 logMAR. Intermediate distance visual acuity (UIVA) was 0.22 ± 0.10 logMAR. Contrast sensitivity outcomes were similar to normal population in photopic conditions and slightly reduced in mesopic conditions of lighting. Defocus curve showed that this multifocal IOL was able to provide a visual acuity (VA) equal or better to 0.16 logMAR between defocus levels of + 1.00 to − 2.50 D. Good patient satisfaction was obtained in quality of vision and satisfaction questionnaires outcomes. Conclusions The Precizon Presbyopic NVA IOL (OPHTEC BV) provides good visual outcomes. This multifocal IOL provides a high percentage of spectacle independence due to good VA at far, intermediate and near distances and satisfactory contrast sensitivity. High patient satisfaction was observed in quality of vision and satisfaction questionnaires with a low percentage of patients manifesting photic phenomena.
Collapse
Affiliation(s)
- Jorge L Alió
- Vissum Corporation, Avda de Denia s/n, Edificio Vissum, 03016 Alicante, Spain.,Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
| | - Pilar Yébana
- Vissum Corporation, Avda de Denia s/n, Edificio Vissum, 03016 Alicante, Spain
| | - Mario Cantó
- Vissum Corporation, Avda de Denia s/n, Edificio Vissum, 03016 Alicante, Spain
| | - Ana B Plaza
- Vissum Corporation, Avda de Denia s/n, Edificio Vissum, 03016 Alicante, Spain
| | - Alfredo Vega
- Vissum Corporation, Avda de Denia s/n, Edificio Vissum, 03016 Alicante, Spain
| | - Jorge L Alió Del Barrio
- Vissum Corporation, Avda de Denia s/n, Edificio Vissum, 03016 Alicante, Spain.,Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
| | - Francisco Lugo
- Vissum Corporation, Avda de Denia s/n, Edificio Vissum, 03016 Alicante, Spain
| |
Collapse
|
13
|
Werner L. Intraocular Lenses: Overview of Designs, Materials, and Pathophysiologic Features. Ophthalmology 2020; 128:e74-e93. [PMID: 32619547 DOI: 10.1016/j.ophtha.2020.06.055] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 06/17/2020] [Accepted: 06/24/2020] [Indexed: 11/29/2022] Open
Abstract
This article provides an overview of intraocular lenses (IOLs) currently used in cataract surgery. Aspects presented include design features related to IOL construction and sites of fixation; optic, filter, and haptic materials; as well as pathophysiologic features of uveal biocompatibility, capsular biocompatibility, and postoperative IOL opacification. This overview also includes supplementary (add-on; piggyback) lenses implanted in eyes that are already pseudophakic and considerations on IOLs used in the pediatric population. Different IOLs are made available to surgeons each year, including lenses with increasingly complex design characteristics owing to advancements in manufacturing and surgical techniques.
Collapse
Affiliation(s)
- Liliana Werner
- Intermountain Ocular Research Center, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah.
| |
Collapse
|